This is a Statement of Work (SOW) for a Cosmetic Polymeric Deck Covering System Replacement on the YRBM(L) 57 ship. The work involves replacing deck tiles on the 03 Level Stairway, with a total area of 127 square feet. The replacement must conform to MIL-D-24613 Type I Class 2 specifications. The document requires accomplishing specific requirements from NAVSEA Standard Items (FY26 CH-1), including surface preparation and treatment for both removed and new deck surfaces. No government-furnished materials (GFM) are specified for this task, and the document is marked with export control warnings regarding technical information subject to ITAR regulations.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHIP: YRBM(L) 57 (YRBM 57) ITEM NO: 634-11-001

COAR: 28 PCN: YRBM-L025

CSWT FILE NO: 634-003 (LCU 1646) CMP: NONE

REVISED: 30 SEP 2024 PLANNER: LOFTIS, OLEN

SSP: YOKO-703-26 1 of 1 ITEM NO: 634-11-001

EXPORT CONTROLLED DATA: This document contains technical information whose export is governed by U.S.

International Traffic in Arms Regulation (ITAR). This information must not be transferred to a foreign person/entity without proper authorization of the U.S. Government. Violations may result in administrative, civil, or criminal penalties.

1. SCOPE:

1.1 Title: Cosmetic Polymeric Deck Covering System Replacement;

accomplish

1.2 Location of Work:

1.2.1 03 Level Stairway (03-68-0-Q)

1.3 Identification:

1.3.1 Not Applicable

2. REFERENCES:

2.1 NAVSEA Standard Items, (FY26 CH-1)

3. REQUIREMENTS:

3.1 Accomplish the requirements of 009-026 of 2.1, including Attachment C for REPLACEMNT of Deck Tiles for cosmetic polymeric deck covering system conforming to MIL-D-24613 Type I Class 2, at each location listed in 1.2. Total square footage is 127 sq ft.

3.1.1 Accomplish the requirements of 009-032 of 2.1, including Table 3, Lines 4, 5, or 6, Columns A and B, for deck surfaces in way of removals.

3.2 Accomplish the requirements of 009-032 of 2.1 for each new and disturbed surface.

4. NOTES:

4.1 None.

5. GOVERNMENT FURNISHED MATERIAL (GFM):

5.1 LLTM:

1. None.

5.2 PUSH MATERIAL:

1. None.

5.3 KITTED MATERIAL:

1. None.