613-124 Ren Exp 47-Bed Dom C Pod Repl AHU_Dwgs Vol III.pdf
PDF 18 MB Posted
- Solicitation number
- 36C24521B0011
About this file
This solicitation seeks a construction contractor to renovate and expand a 47-bed domiciliary pod at a Department of Veterans Affairs medical center. The project includes a complete renovation of an existing 17,600 square foot single-story domiciliary building that is 30 years old, along with a 5,000 square foot addition. Renovations will feature updated finishes, replacement of mechanical and HVAC systems to current standards, and floor plan changes. Asbestos abatement is also required. The estimated construction cost range is $5,000,000 to $10,000,000. The solicitation is restricted to service-disabled veteran-owned small businesses. Interested parties must register on Vendor Information Pages and SAM.gov to be eligible. A pre-bid site visit will be held on a date specified in the solicitation. Questions from the visit must be submitted in writing. Drawings and specifications are available electronically starting September 9, 2021, with bid opening anticipated for October 13, 2021. Award will be made to the responsive and responsible bidder offering the lowest price.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
NEW ADDITIONEXISTING POD C
MATCHLINE
M A
T C
H L
I N
E
BATH
BARIATRIC
SHARED
OFFICE
OFFICE
OFFICE
BARIATRIC
BATH
BARIATRIC
DHT
DHT
SHARED
OFFICE
BATH
BARIATRIC
RES
HAC
OFFICE
OFFICE
GROUP
STAFF LOUNGE
OFFICE
OFFICE
GROUP / PATIENT
KITCHEN
OFFICE
MECH. RM.
QUIET
ROOM
STOR
LAUNDRY
BARIATRIC (FLEX)
BATH
HAC
IT
2 BEDROOM
2 BEDROOM
LOUNGE
LOUNGE
LOUNGE
LOUNGE
GUEST
OFFICE
DHT
2 BEDROOM
2 BEDROOM
2 BEDROOM
2 BEDROOM
2 BEDROOM
2 BEDROOM
2 BEDROOM
2 BEDROOM
BATH
2 BEDROOM
2 BEDROOM
2 BEDROOM
2 BEDROOM
MECH
2 BEDROOM
2 BEDROOM
BATH
BATH
2 BEDROOM
BATH
BATH
2 BEDROOM
2 BEDROOM
BATH
2 BEDROOM
2 BEDROOM
BATH
2 BEDROOM
BATH
2 BEDROOM
SHARED
OFFICE
MECH
(FOR BLDG D)
OFFICE
2 BEDROOM
BATH
BATH
STAFF TLT
BATH
BATH
CLO
EXISTING
COURTYARD
ELEC
BATH
CLO
BATH
BATH
BATH BATH
BATH
BATH
BATH
BATH
BATH
STAFF
TLT
ELEC.
BATH
BATH
STOR
LOUNGE
BATH
BATH
2 BEDROOM
2 BEDROOM
EDUCATION
GROUP
2 BEDROOM
HAC
BARIATRIC
(FLEX)
BATH
CLO
OFFICE
EDUCATION
RES
HAC
RES
HAC
BATH
DHT
LAUNDRY
D I S
P L
A Y
DISPLAY
BIOMED
D I S
P L
A Y
BATH
502C-122A 502C-122
502C-115 502C-114
502C-116
502C-121 502C-121A 502C-124
502C-168
502C-166A
502C-166
502C-164
502C-171
502C-172 502C-170 502C-169
502C-165
502C-159
502C-158
502C-161
502C-105
502C-103
502C-102
502C-101
502C-135
502C-135A
502C-137
502C-136
502C-133
502C-134
502C-138
502C-152
502C-146502C-145
502C-153502C-154
502C-144502C-143
502C-155
502C-144A
502C-156502C-157
502C-160502C-162
502C-130
502C-129
502C-128
502C-128A
502C-129A
502C-127502C-127A
502C-125A
502C-125
502C-119 502C-118A
502C-118
502C-110
502C-110A
502C-109
502C-108A
502C-108
502C-100502C-100A
502C-104
502C-113502C-113A
502C-112A
502C-120
502C-134A
502C-133A
502C-CLO
502C-107
502C-131
502C-119A
502C-123
502C-111A
502C-109A
502C-143A 502C-145A
502C-146A
502C-152A
502C-153A502C-155A
502C-154A
502C-167
502C-106
502C-162A
502C-160A
502C-107A
502C-156A
502C-157A
502C-112
502C-111
502C-142502C-139
502C-148502C-150 502C-151 502C-151A
502C-169A 502C-163
502C-140
502C-117
502C-147
502C-148A
502C-149
502C-126
502C-124A
502C-L2
502C-L3
502C-C3
2C
-C
502C-L1
502C-L5
502C-C5
502C-L4
502C-C6
502C-141
502C-C8
502C-C11
502C-C12
502C-C9
2C
-C
502C-C1
502C-C14
2C
-C
FIRE ALARM CONTROL PANEL
AUXILLARY POWER SUPPLY
SMOKE DETECTOR
MANUAL PULL STATION
HEAT DETECTOR
MONITOR MODULE
CONTROL RELAY MODULE
SPEAKER/STROBE(CEILING)
STROBE ONLY(CEILING)
SPEAKER ONLY(CEILING)
EX = EXISTING
N = NEW
ABBREVIATIONS LEGEND
C = CEILING MOUNT
RL = RELOCATE DEVICE
DEMO = REMOVE DEVICE
NIS = NOT IN SCOPE OF WORK
DOOR HOLDER
ANNUNCIATOR PANEL
WP = WEATHERPROOF
LOCAL SMOKE ALARM
12/11/2020 KLM GLW
FA110
502C
FIRST FLOOR FIRE ALARM
VEG 19.26
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
613-124
VAMC MARTINSBURG, WV 25405
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
12364 W. ALAMEDA PKWY.
SUITE #135
LAKEWOOD CO 80228
(303) 985-2050
WWW.VERITASFIRE.COM
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
LEGEND
P l a n
N o r t h
T r u e
N o r t h
32'16'8'4'0' 2'
1/8" = 1'-0"
FLOOR PLAN- FIRE ALARM
INSTALLATION NOTES
INSTALLATION NOTES:
1. ALL FIRE ALARM EQUIPMENT SHALL BE INSTALLED PER
NFPA 72 AND THE MANUFACTURER'S INSTRUCTIONS.
2. ALL INITIATING DEVICES SHALL BE FIELD LOCATED
BASED UPON THE LOCATION OF DIFFUSERS, LIGHTS,
AND OTHER POTENTIAL OBSTRUCTIONS.
3. WALL MOUNT THE BOTTOM OF ALL AUDIBLE/VISUAL
APPLIANCES AT MIN. 80" A.F.F., NO MORE THAN 96" AFF
OR TOP AT 6" BELOW THE CEILING, WHICHEVER IS
LOWER.
4. ALL WIRING INSTALLATION SHALL CONFORM TO THE
NEC.
5. ALL WIRING SHALL BE INSTALLED IN CONDUIT.
6. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO RETURN ALL WIRES TO THE PANEL
FREE OF OPENS, GROUNDS, SHORTS AND/OR ANY
OTHER CONDITION THAT MAY PREVENT THE PROPER
OPERATION OF THE FIRE ALARM SYSTEM.
7. ALL MATERIALS SHALL BE COMPATIBLE WITH THE
EXISTING HOSPITAL SYSTEM.
8. CONTRACTOR IS TO FIELD VERIFY THAT THE EXISTING
HEAD-END WILL HANDLE THE ADDITIONAL VISUAL &
AUDIBLE LOAD.
9. CIRCUIT NEW EQUIPMENT INTO THE SAME FIRE ALARM
ZONE THAT IS SERVING THE SPRINKLER ZONE.
10. CONFIRM WITH BUILDING MAINTENANCE THAT SMOKE
ALARMS SHALL BE 120 VOLT AND NOT CONNECTED TO
THE FIRE ALARM SYSTEM.
11. LSSI, LLC IS THE SOLE SOURCE FIRE ALARM
CONTRACTOR AT THIS FACILITY.
KEYNOTES
1. AREA NOT IN SCOPE OF WORK
2. NEW EST3 TRANSPONDER WITH VOICE EVACUATION
AMPLIFIERS. PANEL SHOULD ALSO HAVE THE CAPABILITY TO
POWER VISUAL CIRCUITS.
PROJECT SCOPE NARRATIVE
THE SCOPE OF THIS PROJECT IS TO PROVIDE A NEW FIRE ALARM
SYSTEM FOR NEW DOMICILIARY EXPANSION AND THE REMODEL AREA.
FIRE PROTECTION SYSTEM SUBMITTAL - FIRE ALARM
TYPICAL DEVICE MOUNTING HEIGHTS
ACTUATOR
TOP OF UNIT
TOP OF CABINET
ENTIRE LENS OF STROBE
TOP OF DEVICE
CEILING
DIFFUSER
LIGHT
Min
7'6"
(90")
Min
6'8"
(80")
6'0"
(72")
5'4"
(64")
4'0"
(48")
Max
6" below ceiling
Max
8"0"
(96")
ALL HEIGHTS ARE
MEASURED FROM (AFF)
ABOVE FINISHED FLOOR
3'0"
(36")
1'6"
(18")
12/11/2020 KLM GLW
FA111
502C
FIRST FLOOR FIRE ALARM
DEMO
VEG 19.26
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
613-124
VAMC MARTINSBURG, WV 25405
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
12364 W. ALAMEDA PKWY.
SUITE #135
LAKEWOOD CO 80228
(303) 985-2050
WWW.VERITASFIRE.COM
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
P l a n
N o r t h
T r u e
N o r t h
32'16'8'4'0' 2'
1/8" = 1'-0"
FLOOR PLAN- FIRE ALARM - DEMOLITION
INSTALLATION NOTES:
1. DISCONNECT AND REMOVE ALL FIRE ALARM DEVICES IN DEMOLITION AREAS UNLESS NOTED
OTHERWISE. DISCONNECT AND REMOVE ALL ASSOCIATED CONDUIT AND WIRE BACK TO
OVERCURRENT PROTECTION DEVICE. COMPLETELY CUT/CAP CONDUITS IN CONCRETE SLAB
AND IN THE AREA OF WORK PERIMETER. DISCONNECT AND REMOVE ALL ABANDONED
CIRCUITS AND CONDUITS. PROVIDED CONDUIT AND WIRE AS REQUIRED FOR CONTINUITY OF
CIRCUITS TO ANY EXISTING DEVICES TO REMAIN. COORDINATE AND VERIFY REQUIREMENTS
WITHIN NEW AREA OF WORK.
KEYNOTES
1. ALL EXISTING FIRE ALARM DEVICES ARE TO BE REMOVED IN
HATCHED AREA.
PLUMBING SYMBOLS
SYMBOL DESCRIPTION SYMBOL
SANITARY SEWER (BELOW FLOOR)SS
DESCRIPTION SYMBOL DESCRIPTION
STORM DRAIN (BELOW FLOOR)SD
STORM DRAIN OVERFLOW (BELOW FLOOR)SDO
SUBSOIL DRAIN (BELOW FLOOR)SSD
SANITARY SEWER (ABOVE FLOOR)SS
STORM DRAIN (ABOVE FLOOR)SD
STORM DRAIN OVERFLOW (ABOVE FLOOR)SDO
SUBSOIL DRAIN (ABOVE FLOOR)SSD
SANITARY VENT
ACID WASTE (BELOW FLOOR)AW
ACID WASTE (ABOVE FLOOR)AW
ACID VENTAV
DOMESTIC COLD WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER RECIRCULATING
TERMPERED WATER
TEMPERED WATER RECIRCULATING
T
T
SSO
SSO
DRINKING WATER SUPPLY
DRINKING WATER RECIRCULATING
IRRIGATION WATER MAINIRM
NATURAL GASG
FIRE LINEF
SPRINKLER MAINSM
COMPRESSED AIRA
VACUUMV
MEDICAL COMPRESSED AIRMA
OXYGENOX
NITROUS OXIDEN2O
NITROGENN
CARBON DIOXIDEC20
FUEL OIL SUPPLYFOS
FUEL OIL RETURNFOR
FUEL OIL VENTFOV
FUEL OIL FILLFOF
FUEL OIL GAGEFOG
GATE VALVE
GLOBE VALVE
CHECK VALVE
BUTTERFLY VALVE
ECCENTRIC PLUG VALVE
BALL VALVE
STRAINER
UNION
FLANGE
CAP
BLIND FLANGE
BALANCING VALVE
GAS COCK
PRESSURE REGULATING VALVE
SOLENOID VALVE
CONTROL VALVE (2-WAY)
CONTROL VALVE (3-WAY)
THERMOMETER
PRESSURE GAGE
SAFETY RELIEF VALVE
COCK (GAGE, AIRVENT, DRAIN)
PIPE ANCHOR
PIPE GUIDE
PIPE EXPANSION COMPENSATOR
VACUUM BREAKER
SUPERVISED O S & Y VALVE
HUMIDISTAT
TEMPERATURE SENSOR
PRESSURE SENSOR
FLOW MEASURING ELEMENT
TEST PLUG
SIGHT GLASS (FLOW TYPE)
AIR ELIMINATOR
TEMP. & PRESS. RELIEF VALVE
STEAM TRAP
PIPE ELBOW UP
PIPE ELBOW DOWN
PIPE TEE UP
PIPE TEE DOWN
CLEANOUT
FLOOR CLEANOUT
GRADE CLEANOUT
WALL CLEANOUT
FLOOR - FD TRENCH - TD AREA - AD
ROOF DRAIN OR OVERFLOW ROOF
DRAIN
HOSE BIBB
WALL HYDRANT
FIRE DEPARTMENT CONNECTION
FLOW SWITCH
WATER METER
BACKFLOW PREVENTER
FIRE HOSE CABINET
FIRE VALVE CABINET
PLUMBING RISER NUMBER
CONNECT TO EXISTING
WATER CLOSET (WALL HUNG)
WATER CLOSET (TANK TYPE)
WATER CLOSET (FLOOR MOUNTED)
URINAL
LAVATORY (WALL HUNG)
LAVATORY (COUNTER TOP)
SERVICE SINK
FLOOR MOP SINK
SINK (COUNTERTOP SINGLE BOWL)
SINK (COUNTERTOP DOUBLE BOWL)
BATH TUB
DRINKING FOUNTAIN
ELECTRIC WATER COOLER
SHOWER HEADSH-
EWC-
SH-
BT-
SK-
SK-
MS-
SK-
L-
L-
UR-
WC-
WC-
WC-
V
H
S
P
FE
CO
FLCO
GCO
WCO
(DRAINS)
RD-
HB-
WH-
FS
M
FHC
FVC
MEDICAL VACUUMMV THERMOSTATT
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:2
P
M
PP001
PLUMBING SYMBOLS LEGEND AND
ABBREVIATIONS
RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
ROW RIGHT OF WAY
RS RESILIENT SHEET
RT RESILIENT TILE
S
S STAIR / STAIN / SURFACE / SANITARY
SA SUPPLY AIR / SOUND ATTENUATOR
SAN SANITARY
SCH SCHEDULE
SD SMOKE DAMPER / SUB DRAIN / STORM
SEWER
SECT SECTION
SF SUPPLY FAN
SHT SHEET
SIM SIMILAR
SOG SLAB-ON-GRADE
SP SUMP PUMP
SPEC SPECIFICATIONS
SQ SQUARE
SS SERVICE SINK / SANITARY SEWER
SSM SOLID SURFACE MATERIAL
SSO STORM SEWER OVERFLOW
SST STAIR TREAD
SSTL STAINLESS STEEL
STA STATION
STD STANDARD
STE STANDARD TAPERED END
STIFF STIFFENER
STIR STIRRUP
STL STEEL
STOR STORAGE
STR STRUCTURAL
SUSP SUSPENDED
SW SWITCH
SWGR SWITCHGEAR
SYM SYMMETRICAL
T
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TC TOP OF CURB
TE TOP ELEVATION
TEL TELEPHONE
TEMP TEMPERATURE
TERR TERRAZZO
TLT TOILET
TOPO TOPOGRAPHY
TOS TOP OF STEEL
TOW TOP OF WALL
TP TOP OF PAVEMENT
TRANS TRANSVERSE
TS TRANSITION STRIP
TYP TYPICAL
U
UC UNDERCUT
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
UR URINAL
UV UNIT VENTILATOR
V
V VOLT
VAV VARIABLE AIR VOLUME
VC VERTICAL CURVE
VCP VITRIFIED CLAY PIPE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VFD VARIABLE FREQUENCY DRIVE
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W
W WATT / WATER
W/ WITH
W/O WITHOUT
WAGD WASTE ANESTHESIA GAS DISPOSAL
WC WATER CLOSET / WALL COVERING
WD WOOD
WDB WOOD BASE
WDF WOOD FLOOR
WDP WOOD PANEL
WDW WINDOW
WDWF WINDOW FILM
WGD WALL GUARD
WH WATER HEATER / WALL HYDRANT
WP WEATHERPROOF
WPFG WATERPROOFING
WS WATER STOP
WT WEIGHT / WINDOW TREATMENT
WWF WELDED WIRE FABRIC
X
XFMR TRANSFORMER
Y
YD YARD
YH YARD HYDRANT
MIN MINIMUM
MLO MAIN LUGS ONLY
MM MILLIMETER
MO MASONRY OPENING
MP METAL PANEL
MT METAL TRANSITION
MTD MOUNTED
MTG MOUNTING
MULL MULLION
MV MEDICAL VACUUM
N
N NITROGEN
N2O NITROUS OXIDE
NEC NATIONAL ELECTRICAL CODE
NFPA NATIONAL FIRE PROTECTION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
O/S OFFSET
OA OUTSIDE AIR
OBD OPPOSED BLADE DAMPER
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OPNG OPENING
OPP OPPOSITE
OX OXYGEN
OZ OUNCE
P
P PAINT / PUMP / PENDANT
PA PASCAL
PART PARTITION
PAVT PAVEMENT
PC POINT OF CURVATURE / PRIVACY
CURTAIN
PCF POUNDS PER CUBIC FOOT
PED PEDESTAL
PERP PERPENDICULAR
PHC PREHEAT COIL
PHVAC PLUMBING, HEATING, VENTILATING AND
AIR CONDITIONING
PI POINT OF INTERSECTION
PIV POST INDICATOR VALVE
PKG PARKING
PL PLASTIC LAMINATE / PROPERTY LINE /
PLATE
PLAS PLASTER
PLBG PLUMBING
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PNL PANEL
POL
CONC
POLISHED CONCRETE
PR PAIR
PRF POURED RESINOUS FLOORING
PROJ PROJECTION
PRV PRESSURE REGULATING VALVE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT OF TANGENCY
PTB PORCELAIN TILE BASE
PTF PORCELAIN TILE FLOOR
PTVC POINT OF VERTICAL CURVATURE
PTW PORCELAIN TILE WALL
PVC POLYVINYL CHLORIDE
PVI POINT OF VERTICAL INTERSECTION
PVT POINT OF VERTICAL TANGENCY
Q
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QZP QUARTZ POLYMER
R
R RADIUS / REGISTER
RA RETURN AIR
RAF RAISED ACCESS FLOORING
RB RESILIENT BASE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
REF REFERENCE
REFL REFLECTED
REG REGISTER
REINF REINFORCED
REQD REQUIRED
REV REVERSE / REVISION
RF RETURN FAN
RGS RIGID GALVANIZED STEEL
RH ROOF HOOD / RELATIVE HUMIDITY /
REHEAT
RHC REHEAT COIL
RM ROOM
RO ROUGH OPENING
HTG HEATING
HTR HEATER
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
HW HOT WATER
HWC HOT WATER CIRCULATING
HZ HERTZ
I
IA INSTRUMENT AIR
IC INTERCOM
ID INSIDE DIAMETER
IE INVERT ELEVATION
IF INSIDE FACE
IN INCH
INSUL INSULATION
INT INTERIOR
J
JAN JANITOR
JB JUNCTION BOX
JP JOCKEY PUMP
JST JOIST
JT JOINT
K
KC MIL THOUSAND CIRCULAR MILS
KCJ KEYED CONSTRUCTION JOINT
KIT KITCHEN
KPA KILOPASCALS
KS KITCHEN SINK
KV KILOVOLT
KVA KILOVOLT AMPERE
KW KILOWATTS
L
L LITER
LA LABORATORY AIR
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LBS POUNDS
LF LINEAR FEET
LIN LINEAR
LINO LINOLEUM
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMU LIGHTWEIGHT MASONRY UNITS
LONG LONGITUDINAL
LPM LITERS PER MINUTE
LT LIGHT
LT WT LIGHT WEIGHT
LTG LIGHTING
LV LABORATORY VACUUM
LVL LEVEL
LVT LUXURY VINYL TILE
M
M METER
M2 SQUARE METER
M3 CUBIC METER
MA MEDICAL AIR
MAINT MAINTENANCE
MAR MARBLE
MAS MASONRY
MAT MATERIAL
MAX MAXIMUM
MB METAL BASE
MBH 1000 BTUH
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
MET METAL
MFR MANUFACTURER
MG MOTOR GENERATOR / MEDICAL GAS
MH MANHOLE
EWC ELECTRICAL WATER COOLER
EWH ELECTRICAL WATER HEATER
EXH EXHAUST
EXP EXPOSED
EXPN EXPANSION
EXST EXISTING
EXT EXTERIOR
F
F FIRE MAIN
FA FIRE ALARM
FCU FAN COIL UNIT
FD FLOOR DRAIN / FIRE DAMPER
FD / SD COMBINATION FIRE AND SMOKE
DAMPER
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FDR FEEDER
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH
FIX FIXTURE
FL FLOOR
FM FORCE MAIN / FACTORY MUTUAL
FP FIREPROOFING / FIRE PUMP
FPM FEET PER MINUTE
FR FIRE RATED
FRP FIBERGLASS REINFORCED PLASTIC
FS FLOW SWITCH
FT FEET
FTG FOOTING
FVC FIRE VALVE CABINET
G
G GAS / GRILLE
GA GAGE
GALV GALVANIZED
GB GRAB BAR
GBD GRAVITY BACKDRAFT DAMPER
GEN GENERATOR
GFRC GLASS FIBER REINFORCED CONCRETE
GI GALVANIZED IRON
GL GLASS
GLB GLASS BLOCK
GLP GLASS PANEL
GLT GLASS TILE
GP GLAZED PAINT
GPM GALLONS PER MINUTE
GR GRADE
GRV GRAVITY ROOF VENTILATOR
GT GROUT
GWB GYPSUM WALLBOARD
GYP GYPSUM
H
HB HOSE BIBB
HC HEATING COIL
HDNR HARDENER
HDW HARDWARE
HDWD HARDWOOD
HK1E HOOK ONE END
HK2E HOOK TWO ENDS
HM HOLLOW METAL
HNDRL HANDRAIL
HORIZ HORIZONTAL
HP HORSEPOWER
HPT HIGH POINT
HR HOUR
HS HIGH STRENGTH
HT HEIGHT
COMB COMBINATION / COMBINE
COMP COMPRESSIBLE
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS / CONTINUATION
CONTR CONTRACTOR
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CORR CORRIDOR
CP CEMENT PIPE
CPT CARPET
CR CRASH RAIL
CS CONCRETE SEALER
CSF CUBIC FEET PER SECOND
CT CERAMIC TILE / COOLING TOWER
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CTW CERAMIC TILE WALL
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CUYD CUBIC YARD
CW COLD WATER
D
D DRAIN / DIFFUSER
DA DENTAL AIR
DBL DOUBLE
DEPR DEPRESSED
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIP DUCTILE IRON PIPE
DISC DISCONNECT
DISP DISPENSER
DIST DISTRIBUTION
DK DECK
DL DEAD LOAD
DN DOWN
DO DITTO
DPR DAMPER
DR DOOR
DS DOWNSPOUT
DV DENTAL VACUUM
DWG DRAWING
DWL DOWEL
DWP DOMESTIC WATER PUMP
E
EA EACH / EXHAUST AIR
ECT ENTRY CARPET TILE
EF EACH FACE / EXHAUST FAN
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EMBED EMBEDMENT
EMD ESTIMATED MAXIMUM DEMAND
EMT ELECTRICAL METAL TUBING
ENG ENTRANCE GRATING
EP EPOXY PAINT
EQ EQUAL
EQUIP EQUIPMENT
ET EXPANSION TANK / EPOXY TERRAZZO
ETB EPOXY TERRAZZO INTEGRAL COVE
BASE
EVAC MEDICAL GAS EVACUATION
EW EACH WAY
A
A/C AIR CONDITIONING
AB ANCHOR BOLT / AIR BLENDER
ABS ACRYLONITRILE-BUTADIENE-STYRENE
AC ALTERNATING CURRENT / AIR
COMPRESSOR
ACP ASBESTOS CEMENT PIPE
ACU AIR CONDITIONING UNIT
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADJ ADJACENT / ADJUSTABLE
ADR ACCESS DOOR
AFF ABOVE FINISH FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
APC ACOUSTICAL PANEL CEILING
APPRO
X
APPROXIMATELY
APT APARTMENT
ARCH ARCHITECT(URAL)
ASPH ASPHALT
ATB AIR TERMINAL BOX
ATC ACOUSTICAL TILE CEILING
ATD AIR TRANSFER DUCT
ATU AIR TERMINAL UNIT
AUX AUXILIARY
AVG AVERAGE
AWT ACOUSTICAL WALL TREATMENT
AZ AZIMUTH
B
BB BALLED AND BURLAPPED
BD BOARD
BDD BACK DRAFT DAMPER
BE BOTTOM ELEVATION
BL BUILDING LINE
BLDG BUILDING
BLKG BLOCKING
BM BENCH MARK / BEAM
BR BARE ROOT
BRG BEARING
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
C
C/C CENTER TO CENTER
CAB CABINET
CB CIRCUIT BREAKER / CATCH BASIN
CC COOLING UNIT
CE COVER ELEVATION
CEM CEMENT
CFM CUBIC FEET PER MINUTE
CG CORNER GUARD
CH CHILLER
CI CURB INLET / CAST IRON
CIP CAST IRON PIPE
CJ CONTROL JOINT OR CONTRACTION
JOINT
CKT CIRCUIT
CL CENTER LINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CM CENTIMETER
CMH CUBIC METER PER HOUR
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT / CARBON MONOXIDE
CO2 CARBON DIOXIDE
COL COLUMN
6" 6"
C O4"
C O4"
C O
8"
6" 6"
6" 6"
4" 4"
SW
C O
4"
C O
4"
4" A
R E
A
P
LA
N
TE
R D
R A
IN
C O
4"
C O
4"
C O
C O
4"
3/ 4"
C D
D N
. T H
R U
S
LA
B
3/ 4"
C D
D N
. T H
R U
S
LA
B 3/
4" C
D S
P
IL
L
IN
T O P
LA
N
TE
R
(T Y
P
IC
A L
O F
P
LA
N
TE
R D
R A
IN
" A R
E A
A N
C H
O R
1/
2"
1/
2"
1/
2"
1"
1"
1/
2"
1/
2"
1"1"
1/
2"
3"
1/
2"
1/
2"
2" 2" 2"
1/
4"
3/ 4"
1"
2"
2"
1" 3/ 4"
1/
2"
1"
3/ 4"
3/ 4"
1" 2"
2"
2"
3" 2" 2"
2" 2"
1/
2"
W .H
H O
S E
B
IB
B
2"
1/2" H.W. & C.W. CAP
3/4" H.W. & C.W. CAP
1/2" C.W. & H.W. CAP
3/4" H.W. & C.W.
HOSE BIBB
CLOTHES WASHER
HOSE BIBB
1" C.W. CAP
3/4" H.W.-C.W. CAP
2" 4"
4" C
.O
2"
1/ 2"
1/
2"
4"
2" 4"
4"
4"
4" V.T.R.
C .O
4" V.T.R.
4"
C .O
C .O
2"
2"
2"
4"
1/
2" 2"
4"
4"
C .O
1 1/2"
4"
C .O
2"
4" 2"
4"
4"
1/
2"
3"
4"
2"
6"
2"
4"
6"
4"
4" 2"
4"
C .O
4"
4"
4"
2"
4"
2"
4"
1/ 2"
4" V.T.R.
4"
C .O
3"
2" 3"
1/
2"
4"
C .O
2"
4"
4"
2"
2"
4"
1/
2"
2"
2"
4" 4"
2"
2"
2"
C .O
2"
1/
2"
4"
4"
2"
4" V.T.R.
2"
1/
2"
4" 4"
2" 3" V.T.R.
4"
4"
2"
2"
2" 2"
4" V.T.R.
4"
4"
4" C
.O
2"
2"
4"
2" S.P.-V.P. CAP
1 1/2" W.P.-V.P.
CAP 1 1/2"
W.P.
HOSE BIBB
3" S.P.-2" V.P. CAP
1 1/2"
W.P.-V.P. CAP
4" S.P.
2" V.P.
CAP
1 1/2" S.P.-V.P.
HOSE BIBB
CLOTHES
WASHER
2"
2"
2"
4"
2" 2"
2"
2"
4"
4"
4"
4"
4"
2"
6" 6"
4"
2"
2"
2"
4"
4" V.T.R.
2"
1/
2"
3" V.T.R.
4" V.T.R.
2"
3"
4" V.T.R.
4" V.T.R.
1/
2"
4" V.T.R.
4" V.T.R. 3"
2"
2"
4" V.T.R.
4" V.T.R.
4" V.T.R.
4" V
.T .R
4" V.T.R.
4" V.T.R.
4" V
.T .R
4" V.T.R.
4" V.T.R.
A N
C H
O R
1" 1"
1"
1"
1"
W .H
3" 3"
2"
4"
2"
3/ 4"
4" 4"
4"4"
W .H
3/ 4"
4"4"
4"
3/ 4"
3/ 4"
1/
4" 3" 3"
W .H
3" 3"
2"
3"
3/ 4"
W .H
2"
1/
2"
1/
2"
2"
1/
2"
2"
1/
2"
3/ 4"
3"
W .H
W .H
3"
1/
2"
1/
2"
2"
W .H
W .H
W .H
3/ 4"
2-3" REDUCED PRESS
BACK FLOW PREVENT
ORS PIPED IN PARALLEL
A
CDFP EGJLMN
K H B
2 2
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N o rt h
T ru e N or th
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:2
P
M
PD101
DEMOLITION PLUMBING FLOOR
PLAN
RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
1. ALL PLUMBING WITHIN THE AREA SHOWN HATCHED ON THE
DEMOLITION PLANS SHALL BE DEMOLISHED AND REMOVED IN THEIR
ENTIRETY UNLESS OTHERWISE NOTED OR REQUIRED BY OTHER
CONDITIONS IN THESE DOCUMENTS. SEE DRAWINGS OF ALL OTHER
TRADES FOR EXTENT OF DEMOLITION WORK. PLUMBING ITEMS
SHALL INCLUDE DOMESTIC WATER PIPING SYSTEMS INCLUDING PIPE
INSULATION, SANITARY SEWER AND VENT SYSTEMS ABOVE GRADE,
PLUMBING FIXTURES, ETC..
2. APPROXIMATE BELOW GRADE SANITARY SEWER SHOWN. PLUMBING
CONTRACTOR SHALL VERIFY IN FIELD AND COORDINATE WITH
GENERAL CONTRACTOR FOR SLAB DEMOLITION. BELOW GRADE
SANITARY SEWER MAY BE ABANDONED IN PLACE.
3. LOCATION OF DOMESTIC COLD WATER ENTRY TO BUILDING. REMOVE
DOMESTIC COLD WATER STUB UP AFTER THE ISOLATION VALVE AND
PROTECT FOR FUTURE CONNECTION.
4. EXISTING HW AND HWC PIPING FROM CENTRAL PLANT. REMOVE
PIPING SHOWN HATCHED. VERIFY OPERATION OF EXISTING
ISOLATION VALVES AT THE EXISTING CONNECTION TO THE SYSTEM
MAIN PIPING PRIOR TO DEMOLITION. FIELD VERIFY EXISTING
CONDITIONS.
48'24'12'6'3'0' P la n N o rt h
T ru e N or th
3/32" = 1'-0"1 DEMOLITION PLUMBING FLOOR PLAN
W
D
1 2 3 4 5 6 7 8
A
B
C
D
A
CDFP EGJLMN
K H B
S E
E P
P
S E
E P
P
S E
E P
P
S E
E P
P
SEE PP103
SEE PP102
SEE PP103
SEE PP102
502C-151502C-153502C-154
502C-139 502C-140 502C-142 502C-143 502C-145502C-144 502C-146
502C-148502C-156502C-157502C-158
502C-L5
502C-160502C-162502C-166502C-168 502C-106
502C-C11
502C-169
502C-170 502C-172
502C-171
502C-100502C-100A
502C-C1
502C-L1
502C-105
502C-108
502C-109
502C-110
502C-118 502C-119 502C-121
502C-107
502C-111
502C-124 502C-126
502C-L3
502C-130
502C-129
502C-128
502C-127502C-125
502C-122
502C-C3
502C-L2
502C-116
502C-113
502C-112
502C-C5502C-102
502C-101
502C-152
502C-135
502C-145A
502C-146A
502C-149
502C-148A502C-155A
502C-154A
502C-155
502C-138 502C-137
502C-C12
502C-135A
502C-133A
502C-133
502C-122A 502C-C9
502C-117
502C-124A
502C-121A502C-118A
502C-119A
502C-110A
502C-111A
502C-165 502C-161
502C-159 502C-C4 502C-C6 502C-C7
502C-136
502C-159
502C-163
502C-103
502C-104
502C-134
502C-114
502C-115
502C-C2
502C-C4
502C-L4
KEY PLAN
P la n N o rt h
T ru e N or th
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:4
P
M
PP101
OVERALL PLUMBING FOUNDATION
FLOOR PLAN
RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
48'24'12'6'3'0'
P la n N o rt h
T ru e N or th
3/32" = 1'-0"
1 OVERALL PLUMBING FOUNDATION FLOOR PLAN
A
CDFP EGJLMN
K H B
PP201
502C-113
502C-113A
502C-112A
502C-112
502C-114
502C-115
502C-116502C-117
502C-L2
502C-120
502C-122 502C-122A
502C-125 502C-127A
502C-125A
502C-127
502C-128
502C-L3 502C-129
502C-129A
502C-128A
502C-130
502C-131
502C-126 502C-124
502C-121
502C-119
502C-C3
502C-CLO
502C-133
502C-133A
502C-109
502C-110
502C-111
502C-110A
502C-118
502C-119A
502C-118A
502C-107A
4" S
4" S
4" S
4" S
4" S
4" S
4" S
6 4
4" S
4" S
4" S
4" S
4" S
4" S
4" S
4" S
4" S
4" S
502C-124A
502C-121A
502C-111A
2" S
2" S
4" S
4" S
4" S
2" S
2" S
2" S
4" S
2" S
3" S
2" S 2" S
4" S 4" S
4" S
2" S
2" S4" S
4" S
4" S4" S
2" S
2" S
2" S
2" S
4" S
4" S2" S
2" S
4" S4" S
4" S
2" S
2" S
2" S
2" S
4" S
4" S
2" S
2" S
2" S
2" S
4" S
4" S4" S
4" S
4" S
2" S2" S
2" S2" S
MATCH LINE
SEE PP103
MATCH LINE
SEE PP103
1. 4" SANITARY WASTE UP
2. 2" SANITARY VENT UP
3. 2" SANITARY WASTE UP
4. 2" SANITARY WASTE UP TO LAV
5. 2" SANITARY WASTE UP TO FD
6. 2" SANITARY WASTE UP TO SHOWER DRAIN
7. 3" SANITARY WASTE UP TO MOP SINK
8. 4" UP TO CLEANOUT
9. 1/2" COLD WATER UP TO TRAP SEAL PRIMER
10. 4" UP TO FLOOR DRAIN
11. 4" DOMESTIC WATER SERVICE ENTRANCE
SANITARY SEWER KEY NOTES
A. PIPING AND EQUIPMENT SHOWN HALF-TONE IS
EXISTING TO REMAIN. PIPING AND EQUIPMENT
SHOWN BOLD IS NEW.
B. SEE ARCHITECTURAL PLANS FOR EXACT
FIXTURE LOCATION AND ELEVATION.
C. SEE STRUCTURAL DRAWINGS FOR FLOOR
PATCHING.
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N o rt h
T ru e N or th
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:4
P
M
PP102
ENLARGED NORTH PLUMBING
FOUNDATION FLOOR PLAN
RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
24'12'6'3'1'-6"0'
P la n N o rt h
T ru e N or th
3/16" = 1'-0"
1 ENLARGED NORTH PLUMBING FOUNDATION FLOOR PLAN
A
CDFP EGJLMN K H B
502C-134
502C-135
502C-136
502C-135A
502C-138502C-137
502C-156
502C-157
502C-157A
502C-156A
502C-158
502C-159
502C-163 502C-161 502C-L5
502C-165 502C-167
502C-169A 502C-169
502C-170
502C-171
502C-172
502C-L1
502C-104
502C-103
502C-102
502C-101
502C-100502C-100A
502C-105
502C-108
502C-106
502C-168 502C-166
502C-166A
502C-164
502C-162
502C-160A
502C-162A
502C-160
502C-C5
6 4
4" S
4" S
4" S
4" S 4" S
4" S
4" S
6" S
4" S
6" S
4 9
2" S
4" S
4" S
2" S
4" S
4" S
4" S
4" S
4" S
4" S
4" S
2" S
2" S
4" S
2" S
2" S
4" S 4" S
2" S
2" S
2" S
4" S 2" S
4" S
4" S
4" S4" S
2" S
2" S
4" S
2" S
2" S
4" S
EXISTING
POD C
NEW ADDITION
M A
T C
H L
IN
E
S E
E P
P
M A
T C
H L
IN
E
S E
E P
P
MATCH LINE
SEE PP102
MATCH LINE
SEE PP102
502C-C4
1 9
54" S
4" S
4" S
2" S
4" CW
9 4 1
1. 4" SANITARY WASTE UP
2. 2" SANITARY VENT UP
3. 2" SANITARY WASTE UP
4. 2" SANITARY WASTE UP TO LAV
5. 2" SANITARY WASTE UP TO FD
6. 2" SANITARY WASTE UP TO SHOWER DRAIN
7. 3" SANITARY WASTE UP TO MOP SINK
8. 4" UP TO CLEANOUT
9. 1/2" COLD WATER UP TO TRAP SEAL PRIMER
10. 4" UP TO FLOOR DRAIN
11. 4" DOMESTIC WATER SERVICE ENTRANCE
SANITARY SEWER KEY NOTES
A. PIPING AND EQUIPMENT SHOWN HALF-TONE IS
EXISTING TO REMAIN. PIPING AND EQUIPMENT
SHOWN BOLD IS NEW.
B. SEE ARCHITECTURAL PLANS FOR EXACT
FIXTURE LOCATION AND ELEVATION.
C. SEE STRUCTURAL DRAWINGS FOR FLOOR
PATCHING.
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N o rt h
T ru e N or th
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:5
P
M
PP103
ENLARGED SOUTH PLUMBING
FOUNDATION FLOOR PLAN
RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
24'12'6'3'1'-6"0'
P la n N o rt h
T ru e N or th
1 ENLARGED SOUTH PLUMBING FOUNDATION FLOOR PLAN
1 2 3 4 5 6 7 8
A
B
C
D
502C-139 502C-140 502C-142
502C-143 502C-143A
502C-144A
502C-144 502C-145
502C-145A
502C-146A 502C-146
502C-C7
502C-147
502C-148
502C-149
502C-148A
502C-150 502C-151A
502C-L4
502C-151502C-152502C-153 502C-152A
502C-153A
502C-141
502C-154
502C-154A
502C-155A 1
6 4
4" S
4" S
4" S
4" S 4" S
4" S
4" S
4" S 4" S
4" S
4" S
2" S
2" S
2" S 2" S
2" S
2" S
4" S
2" S
2" S
4" S 4" S
2" S
2" S
2" S
4" S
4" S
4" S
2" S
2" S
2" S
2" S
2" S2" S
2" S
2" S
4" S
EXISTING
POD C
M A
T C
H L
IN
E
S E
E P
P
M A
T C
H L
IN
E
S E
E P
P
2" S 2" S
2" S
502C-C4
502C-C8
FL.C.O.
1. 4" SANITARY WASTE UP
2. 2" SANITARY VENT UP
3. 2" SANITARY WASTE UP
4. 2" SANITARY WASTE UP TO LAV
5. 2" SANITARY WASTE UP TO FD
6. 2" SANITARY WASTE UP TO SHOWER DRAIN
7. 3" SANITARY WASTE UP TO MOP SINK
8. 4" UP TO CLEANOUT
9. 1/2" COLD WATER UP TO TRAP SEAL PRIMER
10. 4" UP TO FLOOR DRAIN
11. 4" DOMESTIC WATER SERVICE ENTRANCE
SANITARY SEWER KEY NOTES
A. PIPING AND EQUIPMENT SHOWN HALF-TONE IS
EXISTING TO REMAIN. PIPING AND EQUIPMENT
SHOWN BOLD IS NEW.
B. SEE ARCHITECTURAL PLANS FOR EXACT
FIXTURE LOCATION AND ELEVATION.
C. SEE STRUCTURAL DRAWINGS FOR FLOOR
PATCHING.
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N o rt h
T ru e N or th
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:0
P
M
PP104
ENLARGED ADDITION PLUMBING
FOUNDATION FLOOR PLAN
RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
24'12'6'3'1'-6"0'
P la n N o rt h
T ru e N or th
1 ENLARGED ADDITION PLUMBING FOUNDATION FLOOR PLAN
1 2 3 4 5 6 7 8
A
B
C
D
A
CDFP EGJLMN
K H B
S E
E P
P
S E
E P
P
S E
E P
P
S E
E P
P
SEE PP107
SEE PP106
SEE PP107
SEE PP106
502C-112 502C-113
502C-128
502C-127502C-125
502C-129
502C-C3
502C-130
502C-133
502C-134
502C-135
502C-139 502C-140
502C-141
502C-142 502C-143 502C-144
502C-145 502C-146
502C-148502C-151
502C-C7
502C-152502C-153502C-154
502C-156
502C-157502C-158
502C-169502C-170502C-172
502C-171
502C-100502C-100A
502C-C1
502C-C4
502C-155
502C-138
502C-C12
502C-137
502C-161502C-163502C-165
502C-160502C-162502C-166502C-168
502C-105
502C-103
502C-109
502C-110
502C-118
502C-119
502C-124 502C-126
502C-131
502C-122
502C-116
502C-115
502C-111
502C-108
502C-114
502C-121
502C-113A
502C-112A
502C-111A
502C-110A 502C-119A
502C-118A 502C-121A
502C-124A
502C-122A
502C-127A
502C-125A
502C-133A
502C-135A
502C-136
502C-156A
502C-157A
502C-154A
502C-155A
502C-152A
502C-153A
KEY PLAN
P la n N o rt h
T ru e N or th
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:2
P
M
PP105
OVERALL PLUMBING FLOOR PLAN RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
48'24'12'6'3'0'
P la n N o rt h
T ru e N or th
3/32" = 1'-0"
1 OVERALL PLUMBING FLOOR PLAN
A
CDFP EGJMN
K H B
PP201
502C-112
502C-113 502C-114
502C-115
502C-116
502C-117
502C-111
502C-112A
502C-113A
502C-C2
502C-122
502C-125 502C-127
502C-C3
502C-124
502C-126
502C-128
502C-129
502C-128A
502C-129A
502C-L3
502C-130
502C-107
502C-109
502C-110
502C-C2
502C-133
502C-133A
502C-119
502C-118
502C-121
502C-131
502C-CLO
502C-122A
502C-120
502C-107A
502C-124A
502C-121A
A
B
A
B
2 1
5 5
5 5
FL.C.O.
FL.C.O.
2" HW
3" CW
3" CW
2" HW
2" HW3" CW
2" HW3" CW
1 1/2" HW3" CW 1 1/2" HW
3" CW
1" HW
1" HW
1" HW3" CW
3" CW
3" CW
FL.C.O.
P-104
P-413 P-704
P-104
P-413
P-704
P-704
P-413
P-104
P-104
P-704
P-413
B
A
A 3 4
B
502C-118A
502C-119A
P-103
P-413 P-704
P-103
P-413
P-704
B
A
A
B
FD-C
FD-C
FD-C
FD-C
P-103 P-413FD-C
P-103
P-413 P-704
P-103
P-413 P-704
B
A
B
FD-C
FD-C
A
3 4
502C-127A
502C-125A
A34
B
P-413
FD-C
P-104
P-103 P-414
P-414
P-103
P-103
P-413
P-704
P-103
P-413P-704
B
A 34
B
FD-C
FD-C
502C-109A
502C-108A
P-704
P-704
P-608
P-804
1 1/2" V
1/2" CW
D
D
3/4" CW
FD-C
FD-C
B
A
A
A
B
B
A
MATCH LINE
SEE PP107
MATCH LINE
SEE PP107
A
A
C
C
A34
C
B
2 1
FD-E
C
C
CC
C C
C
C
C
C
C
2" V
2" V
FD-C
P-704
A. 1/2" DOMESTIC HOT & COLD WATER DROP
B. 1" DOMESTIC COLD WATER DROP
C. 1/2" DOMESTIC COLD WATER DROP TO TP-2 & DN TO FLOOR DRAIN.
D. 3/4" COLD WATER CONNECT TO EXISTING WALL HYDRANT
E. CONNECT NEW 2" HW AND 1' HWC TO EXISTING FROM THE
CENTRAL PLANT
DOMESTIC WATER KEY NOTES
1. 4" SANITARY WASTE DN
2. 2" SANITARY VENT DN
3. 2" SANITARY WASTE DN
4. 1-1/2" SANITARY VENT DN
5. EXISTING VENT THROUGH ROOF
6. NEW 4" VENT THROUGH ROOF
SANITARY SEWER KEY NOTES
A. PIPING AND EQUIPMENT SHOWN HALF-TONE IS
EXISTING TO REMAIN. PIPING AND EQUIPMENT
SHOWN BOLD IS NEW.
B. SEE ARCHITECTURAL PLANS FOR EXACT
FIXTURE LOCATION AND ELEVATION.
C. SEE STRUCTURAL DRAWINGS FOR FLOOR
PATCHING.
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N o rt h
T ru e N or th
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:3
P
M
PP106
ENLARGED NORTH PLUMBING
FLOOR PLAN
RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
24'12'6'3'1'-6"0'
P la n N o rt h
T ru e N or
3/16" = 1'-0"1 ENLARGED NORTH PLUMBING FLOOR PLAN
A
CDFP EGJLMN K H B
502C-108
502C-105
502C-L1 502C-104
502C-103
502C-102
502C-101
502C-100
502C-100A
502C-171
502C-172
502C-170
502C-169
502C-106
502C-168
502C-166 502C-162
502C-160
502C-L5
502C-161502C-163502C-165 502C-167
502C-169A
502C-159
502C-158
502C-157
502C-156
502C-156A
502C-157A
502C-135
502C-136
502C-137 502C-138
502C-135A
502C-134
502C-164
502C-166A
502C-160A
502C-162A
A
B
A
B
B
A
A
4 3
4 3
B
DOMESTIC WATER CIRCULATION
PUMP 502C-DWCP-1 & 2
SEE DETAIL 3/PP501
DOMESTIC WATER
ENTRANCE
SEE DETAIL 7/PP501
DOMESTIC WATER
CIRCULATION VALVE
SEE DETAIL 13/PP501
3" CW 2" HW
B
A
B
B
4 3
A
3/4" HW
3" CW
3" CW 3/4" HWC
FL.C.O.
1" CW
1" CW
3/4" CW
1" HWC
2" HW
2" HW
2" HW
2" CW
1 1/2" HW
P-103 P-414
P-414
P-103
P-413
FD-C
P-104
P-413
P-704
P-413
P-704
FD-C
FD-C
P-103
P-103
P-104
P-413
P-704
FD-C
P-103
P-413
FD-C
P-704
FD-C 43
P-413
A
P-413
FD-C
P-704
P-103
1 1/2" HW2" CW
P-528
2" HW 1" CW1" HWC
2" HW
1" HWC
3/4" HWC
3/4" HWC
P-103
1 1/2" CW
1 1/2" HW
2" V
1 1/2" CW
2" V
FD-E
IN 60" LONG ,12”
WIDE, 8” DEEP
TRENCH
P-413
P-604
502C-C1
502C-C4
EXISTING
POD C
NEW ADDITION
3" CW1" CW
1/2" CW
A
B
MATCH LINE
SEE PP106
MATCH LINE
SEE PP106
M A
T C
H L
IN
E
S E
E P
P
M A
T C
H L
IN
E
S E
E P
P
3" CW
1 1/2" HW
FD-E
FD-E
FL.C.O.
C
C
P-804
C
C
C
C
C
C
BACKFLOW
PREVENTER
BFP-1
WATER HAMMER
ARRESTER (TYP)
P-704
P-704
E
A. 1/2" DOMESTIC HOT & COLD WATER DROP
B. 1" DOMESTIC COLD WATER DROP
C. 1/2" DOMESTIC COLD WATER DROP TO TP-2 & DN TO FLOOR DRAIN.
D. 3/4" COLD WATER CONNECT TO EXISTING WALL HYDRANT
E. CONNECT NEW 2" HW AND 1' HWC TO EXISTING FROM THE
CENTRAL PLANT
DOMESTIC WATER KEY NOTES
1. 4" SANITARY WASTE DN
2. 2" SANITARY VENT DN
3. 2" SANITARY WASTE DN
4. 1-1/2" SANITARY VENT DN
5. EXISTING VENT THROUGH ROOF
6. NEW 4" VENT THROUGH ROOF
SANITARY SEWER KEY NOTES
A. PIPING AND EQUIPMENT SHOWN HALF-TONE IS
EXISTING TO REMAIN. PIPING AND EQUIPMENT
SHOWN BOLD IS NEW.
B. SEE ARCHITECTURAL PLANS FOR EXACT
FIXTURE LOCATION AND ELEVATION.
C. SEE STRUCTURAL DRAWINGS FOR FLOOR
PATCHING.
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N o rt h
T ru e N or th
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:4
P
M
PP107
ENLARGED SOUTH PLUMBING
FLOOR PLAN
RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
24'12'6'3'1'-6"0'
P la n N o rt h
T ru e N or
3/16" = 1'-0"1 ENLARGED SOUTH PLUMBING FLOOR PLAN
1 2 3 4 5 6 7 8
A
B
C
D
502C-154
502C-153
502C-152
502C-151
502C-143
502C-142502C-140502C-139
502C-144
502C-145
502C-146
502C-147
502C-148
502C-149
502C-L4
502C-151A
502C-150
502C-148A
502C-153A
502C-152A502C-154A
502C-155A
502C-143A
502C-144A
502C-145A
502C-146A
B
4 3
A
B
B
A
B
1 1/2" HW
3" CW3" CW 1 1/2" HW
P-704
FD-C
P-413
P-413
FD-C
P-704
P-704
FD-C
P-413
P-413
FD-C
4 P-704
B
A
4 3
P-413
FD-C
P-103
P-704
B
A
A
P-103
P-103
P-103
P-103
4 3
A
P-413
P-104
P-704
FD-C
A
B
4 3
P-413
FD-C
P-103
P-704
B
B
FD-C
P-103
P-413
P-704
FD-C
P-103
P-413
P-704
FD-C
P-103
P-812
FD-C
1" HW 3" CW
1 1/2" HW3" CW
1 1/2" HW3" CW
1 1/2" HW3" CW 2" V2" V3/4" HWC
3" CW
3" CW
2" V
2" V 2" V2" V
EXISTING
POD C
P-704
M A
T C
H L
IN
E
S E
E P
P
M A
T C
H L
IN
E
S E
E P
P
FL.C.O.
P-413
P-604
P-528
C
C
C
C
C
C
C
C
A A
C
502C-C4
B
A. 1/2" DOMESTIC HOT & COLD WATER DROP
B. 1" DOMESTIC COLD WATER DROP
C. 1/2" DOMESTIC COLD WATER DROP TO TP-2 & DN TO FLOOR DRAIN.
D. 3/4" COLD WATER CONNECT TO EXISTING WALL HYDRANT
E. CONNECT NEW 2" HW AND 1' HWC TO EXISTING FROM THE
CENTRAL PLANT
DOMESTIC WATER KEY NOTES
1. 4" SANITARY WASTE DN
2. 2" SANITARY VENT DN
3. 2" SANITARY WASTE DN
4. 1-1/2" SANITARY VENT DN
5. EXISTING VENT THROUGH ROOF
6. NEW 4" VENT THROUGH ROOF
SANITARY SEWER KEY NOTES
A. PIPING AND EQUIPMENT SHOWN HALF-TONE IS
EXISTING TO REMAIN. PIPING AND EQUIPMENT
SHOWN BOLD IS NEW.
B. SEE ARCHITECTURAL PLANS FOR EXACT
FIXTURE LOCATION AND ELEVATION.
C. SEE STRUCTURAL DRAWINGS FOR FLOOR
PATCHING.
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N o rt h
T ru e N or th
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:5
P
M
PP108
ENLARGED ADDITION PLUMBING
FLOOR PLAN
RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
24'12'6'3'1'-6"0'
P la n N o rt h
T ru e N or th
1 ENLARGED ADDITION PLUMBING FLOOR PLAN
MN
1/2" TRAP
SEAL
PRIMER
PIPING
2" S UP TO
LAV
2" S UP TO
SHOWER
DRAIN
4" S UP TO
TOILET
2" S UP TO
FLOOR
DRAIN
4" S UP
TO TOILET
2" S UP TO
FLOOR
DRAIN
2" S UP TO
SHOWER DRAIN
2" S UP TO
LAV
TRAP SEAL
PRIMER PIPING
4" S
4" S 2" S
2" S
2" S
2" S
4" S
4" S
2" S UP TO TRAP
SEAL PRIMER
UP TO TRAP
SEAL PRIMER
MN
P-103
FD-C
P-413
P-704
2" V DN
1" CW DN
TO TOILET
1/2" CW & HW DN
TO SHOWER
1/2" CW & HW DN
TO LAVATORY
2" V DN TO
LAVATORY
2" VENT DN
1" CW DN TO
TOILET
TRAP SEAL
PRIMER
P-103
FD-C
P-413
P-704
2" V
2" V
1 1/2" V
2" HW
3" CW
3" CW
2" HW
A. PIPING AND EQUIPMENT SHOWN HALF-TONE IS
EXISTING TO REMAIN. PIPING AND EQUIPMENT
SHOWN BOLD IS NEW.
B. SEE ARCHITECTURAL PLANS FOR EXACT
FIXTURE LOCATION AND ELEVATION.
C. SEE STRUCTURAL DRAWINGS FOR FLOOR
PATCHING.
00KEYNOTES
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:0
P
M
PP201
LARGE SCALE PLUMBING PLANS RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
3/8" = 1'-0"1 LARGE SCALE FOUNDATION PLUMBING PLAN TYPICAL
3/8" = 1'-0"
2 LARGE SCALE PLUMBING PLAN TYPICAL TOILET
12'6'3'1'-6"9"0'
P la n N o rt h
T ru e N or th
P la n N o rt h
T ru e N or
FD-C P-704
P-413
P-103
FD-CP-704
P-413
P-103
FD-C
P-413
P-103
502C-118A 502C-119A502C-120
P-413
P-103
FD-C P-704P-704 FD-C
P-103
P-413
502C-105
502C-111A502C-110A
P-413
P-103
FD-CP-704 P-704FD-C
P-103
P-413
502C-109A502C-108A
P-413
P-103
FD-CP-704 P-704FD-C
P-103
P-413
FD-C
P-413
P-104
502C-121A 502C-124A 502C-122A
P-413
P-104
FD-C P-704P-704 FD-C
P-104
P-413
502C-130 502C-225A502C-127A
P-413
P-103
FD-CP-704 P-704FD-C
P-103
P-413
502C-160A502C-162AP-413
P-103
FD-CP-704 P-704FD-C
P-103
P-413
P-704
502C-128A502C-129A
P-413
P-103 P-103
P-413
502C-151A
P-704FD-C
P-103
P-413
502C-145A502C-146A
P-413
P-103
FD-CP-704 P-704FD-C
P-103
P-413
P-704
1-1/2" 2"
2"
4"4" 2"
2"
1-1/2"
1-1/2"
2"2"
4"4" 2"
2"
1-1/2"
1-1/2" 2"
2"
4"4" 2"
2"
1-1/2"
1-1/2"
2"2"
4"4" 2"
2"
1-1/2"
4"
4"
2"
2"
2" 4"
4"
2"
2"
4" 4"
2"
2"
4"
4"
2"
2" 4"
4" 2"
2"
2"
4" 4"
1-1/2"2"2" 1-1/2"
2" 2"
1-1/2"
2"
4"
4"4"4"
2" 2" 2"2"
2"2" 2"
2"
1-1/2" 2" 2"
1-1/2"
4"
2"2"
1-1/2"
2"2"1-1/2"
1-1/2"
2"
4"
2"
4" 4"
4"
4"4"
2"
4"
502C-133A502C-134A
P-413
P-103 P-103
P-413
502C-135A
P-103
P-413
C
A
B
B
P-413
1-1/2"
2"
502C-158A 502C-166A
P-704FD-C
P-104
P-413
P-704
1-1/2" 2"
4" 2"
FD-C
P-413
P-103
502C-167
1-1/2"
2"
4"
2"
2"
502C-149
P-0000
FD-C
502C-143A502C-144A
P-413
P-103
FD-CP-704 P-704FD-C
P-103
P-413
4"
2"
2"
502C-148A
P-704FD-C
P-103
P-413
2"
502C-153A502C-152A
P-413
P-103
FD-CP-704 P-704FD-C
P-103
P-413
4"
2"
2"
502C-155A502C-154A
P-413
P-103
FD-CP-704 P-704FD-C
P-103
P-413
4"
2"
2"
C
A
502C-157A502C-156AP-413
P-103
FD-CP-704 P-704FD-C
P-103
P-413
P-704
1-1/2" 2"
2"
4"4" 2"
2"
1-1/2"
2"
2"
1-1/2"
2"
4"
2"
4"
FD-C P-704
EXISTING PIPING EXISTING PIPING
EXISTING 4" VENT
THRU ROOF
EXISTING 4" VENT
THRU ROOF
EXISTING 4" VENT
THRU ROOF
EXISTING 4" VENT
THRU ROOF
4"4" 4"
2"
1-1/2"
2"
1-1/2"
2" 2"
2"
1-1/2" 1-1/2"
2"
2"
1-1/2"
2-1/2"2-1/2"
4" VENT
THRU ROOF
1-1/2"
2"2"
4"4" 2"
2"
1-1/2"
2"
4"
1-1/2"
2"2"
4"4" 2"
2"
1-1/2"
2"
4"
4" VENT
THRU ROOF
2"2"
4" VENT
THRU ROOF
2"
1-1/2"
2"
2"
2"
2"
1-1/2"
4"4" 4"
4"
4"
4"
2" 2" 2"2"
4" VENT
THRU ROOF EXISTING 4" VENT
THRU ROOF
EXISTING 4" VENT
THRU ROOF
EXISTING 4" VENT
THRU ROOF
EXISTING 4" VENT
THRU ROOF
EXISTING 4" VENT
THRU ROOF
EXISTING SANITARY
EXITING THE BUILDING
EXISTING SANITARY
EXITING THE BUILDING
P-704FD-CFD-CP-704P-704FD-CFD-CP-704
4"
1-1/2" 2"
2"
4"4" 2"
2"
1-1/2"
2"
1-1/2" 2"
2"
4"4" 2"
2"
1-1/2"
2"
FD-EFD-E
FD-E
2"
4" 2"
C.O. C.O.
C.O.C.O.
C.O.
C.O.
502C-112A 502C-113A
EXISITNG 4" VENT
THRU ROOF
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:0
P
M
PP301
SANITARY SEWER RISER DIAGRAM RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
NTS1 SANITARY SEWER RISER DIAGRAM
P-413P-103
502C-118A502C-111A502C-110A502C-109A 502C-112A
P-704P-413P-103 P-704P-413 P-103
1/2" CW
1/2" HW
1" CW
502C-108A 502C-120
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
502C-121A 502C-124A
P-704P-413 P-104
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1" CW
502C-122A 502C-127A
P-704P-413P-103 P-704P-413 P-103
502C-125A
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
1" CW1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
P-704P-413P-103 P-704P-413 P-103
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
P-704P-413P-103 P-704P-413 P-103
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
P-704 P-413 P-103P-704 P-413P-103
1/2" CW
1/2" HW 1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
P-704 P-413 P-104P-704 P-413P-104
1/2" CW
1/2" HW 1/2" CW
1/2" HW
1" CW 1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
P-414
502C-129A
P-103 P-414P-103
502C-128A
P-414
502C-134A
P-103 P-414P-103
502C-133A
P-704P-413P-103
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1" CW
502C-135A 502C-144A 502C-143A
P-704 P-413 P-103P-704 P-413P-103
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
A
A B
B
D
C
C
D
3" CW
3" CW
3" CW
3" CW
3" CW2" HW
1-1/2" HW
3" CW
2" HW
1-1/2" HW
3" CW
2" HW2" HW
P-704 P-413 P-103P-704 P-413P-103
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
502C-146A 502C-145A
P-812 P-103P-704 P-413
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
502C-149 502C-148A
P-704P-413 P-103
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1" CW
502C-151A
P-704 P-413 P-103P-704 P-413P-103
1/2" CW
1/2" HW
1" CW1" CW
1/2" CW
1/2" HW
502C-152A 502C-153A
P-704 P-413 P-103P-704 P-413P-103
1/2" CW
1/2" HW
1" CW1" CW
1/2" CW
1/2" HW
502C-154A 502C-155A
P-704 P-413 P-103P-704 P-413P-103
1/2" CW
1/2" HW
1" CW1" CW
1/2" CW
1/2" HW
502C-156A 502C-157A
P-528
1/2" CW
1/2" HW
502C-158
P-704 P-413 P-103P-704 P-413P-103
1/2" CW
1/2" HW
1" CW1" CW
1/2" CW
1/2" HW
502C-162A 502C-160A
P-413 P-704P-104
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
502C-166A
P-413P-103
1" CW
1/2" CW
1/2" HW
502C-167 D
2" HW FROM EXISTING
CORE BUILDING
1" HWC FROM EXISTING
CORE BUILDING
P-812
2" HW
1" CW
1-1/2" CW
2" HW
1-1/2" CW
1-1/2" HW
2" HW
2" CW
1-1/2" HW
2" CW
1/2" CW
1/2" HW
2" CW
1-1/2" HW
2" CW
1-1/2" HW1-1/2" HW
3" CW
1" CW
1" CW
3" CW
DOMESTIC WATER
CIRCULATION PUMP
502C-DWCP-1 & 2
SEE DETAIL 3/PP501
DOMESTIC WATER
ENTRANCE
SEE DETAIL 7/PP501
3" CW
1-1/2" HW
3" CW
1-1/2" HW
3" CW
1-1/2" HW
3" CW
1" HW
3" CW
1" HW
1-1/2" HW
1" HWC
1" HW
1" HW
3" CW 3" CW 3" CW
1" HW
1-1/2" HW
1" HW
1-1/2" HW
1-1/2" HW
3" CW3" CW
3" CW
1-1/2" HW
TRAP SEAL PRIMER (TYP)
SEE DETAIL 12/PP501
TRAP SEAL PRIMER (TYP)
SEE DETAIL 12/PP501
P-704 P-704 P-704 P-704
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1" CW
1/2" CW
1/2" HW
1" CW
TRAP SEAL PRIMER (TYP)
SEE DETAIL 12/PP501
P-812
P-604
P-608
502C-119A502C-113A
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:0
P
M
PP302
DOMESTIC WATER RISER DIAGRAM RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
NTS1 DOMESTIC WATER RISER DIAGRAM
SHUT-OFF VALVE
CHECK VALVE
BALANCING VALVE (SET AT 1 GPM)
FLOW
COLD
WATER SUPPLY
1/2" COLD WATER SUPPLY
ISOLATION VALVE
TP-2 TRAP
PRIMER FITTING
SEE DRAWINGS FOR LOCATION
FINISHED FLOOR
FLOOR DRAIN
BRAZED CONNECTION TO
MALE ADAPTER INTO
FLOOR
DRAIN
1/2"
1/2"
1/2"
DCW & DHW SUPPLY
ISOLATION VALVES
3/4" DCW & 3/4" DHW
WALL
P-812
DCW & DHW HOSES
CLW2" EQUIP INDIRECT WASTE
DRAIN TO FLOOR SINK
4" FLOOR SINK
FINISHED FLOOR
WATER HAMMER ARRESTER
DOMESTIC COLD
WATER CIRC PUMPS
DOMESTIC COLD
WATER CIRC PUMPS
FOR CONTINUATION
AND SIZE, SEE
PLUMBING PLANS
GLOBE VALVE
INSULATION
CHECK VALVE
(TYPICAL)
FINISHED FLOOR
PIPE SUPPORTS AS
REQUIRED
ISOLATION VALVE
(TYPICAL)
PRESSURE
GAUGE (TYPICAL)
DUPLEX IN-LINE
PUMPS
UNION/FLANGE
(TYPICAL)
STRAINER (TYPICAL)
GAUGE COCK
DRAIN VALVE
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:0
P
M
PP501
PLUMBING DETAILS RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTINSBURG, WV 25405
613-124
502C
12/11/2020 KRC BDB
CONSTRUCTION DOCUMENTS
(Contract Deliverable CD 100%)
VEG 19.26
NTS13 DOMESTIC WATER CIRCULATION VALVING DETAIL
NTS12 TRAP SEAL PRIMER
NTS9 LAVATORY / SINK PIPING
NTS6 VERTICAL PIPE SLEEVE
NTS5 HORIZONTAL PIPE SLEEVE
NTS
11 PIPE HANGER
NTS2 TRAPEZE PIPE HANGER
NTS4 FLOOR DRAIN
NTS8 TOILET CARRIER
NTS
1 SHOWER PIPINGNTS
10 CLOTHES WASHER
NTS7 DOMESTIC WATER ENTRANCE
NTS3 DOMESTIC COLD WATER CIRCULATION PUMPS
PLUMBING FIXTURE SCHEDULE
MARK DESCRIPTION
WASTE VENT CW
WASTE F.U.PIPE CONNECTIONS
BASIS OF DESIGN OR EQUAL MANUFACTURER AND MODEL NUMBER
P-103 1"2"4"
PROVIDE SUPPLY STOPS, SUPPLY RISERS, P TRAPS, TAILPIECES, AND ALL NECESSARY ACCESSORIES FOR PROPER INSTALLATION OF EACH FIXTURE.
WALL HUNG WATER CLOSET
P-104 1"2"4"
P-413 1/2"1-1/2"2" 1/2" DROP IN BOWL WITH MANUAL FAUCET, GRID DRAIN THERMOSTATIC MIXING VALVE, OFFSET TAILPIECE AND P-TRAP AMERICAN STANDARD "AQUALYN" NO. 0476.028 WITH "MONTERREY" NO. 5502.140 FAUCET OR EQUAL
WALL HUNG BACK OUTLET TOILET WITH SENSOR FLUSH VALVE AMERICAN STANDARD NO. 3351.660 OR EQUAL
SHOWER WITH ANTISCALD VALVE, HEAD AND HAND HELD HEAD 1/2"1-1/2"2" 1/2" SHOWER MIXING ANTISCALD VALVE WITH FIXED AND HAND HELD HEADS SPEAKMAN SM3460 OR EQUALP-704
P-414 1/2"1-1/2"2" 1/2"WALL HUNG VITEROUS CHINA LAVATORY WALL HUNG VITREOUS CHINA BOWL WITH MANUAL FAUCET, GRID DRAIN, THERMOSTATIC MIXING VALVE, OFFSET TAILPIECE AND P-TRAP AMERICAN STANDARD "COMRADE" NO.0124.131 WITH "MONTERREY" NO. 5502.140 FAUCET OR EQUAL
WATER F.U.
HW
WRIST
BLADES
ELECTRONIC
SENSOR
PRIVATE
0.71
1.42
0.71
YESNO
YESNO
NO
NO
NO
YES
YES
NO
WATER SUPPLY BOX 3/4"NANA 3/4" WALL BOX WITH QUARTER TURN BALL VALVES AND 2" DRAIN GUY GREY NO. T200QT OR EQUALP-812 NONO
P-528 1/2"1-1/2"2" 1/2"SINGLE COMPARTMENT STAINLESS STEEL SINK NOYES SINGLE COMPARTMENT STAINLESS STEEL SINK WITH MANUAL GOOSENECK SPOUT FAUCAET AND TAILPIECE TO ACCEPT DISCHARGE FROM DISHWASHER ELKAY MODEL NO. CR2521 WITH NO. LK810GN04T4 FAUCET OR EQUAL
WALL HYDRANT 3/4"NANA NA KEYED WALL HYDRANT WITH VACUUM BREAKER INSTALLED IN SAME SPACE AS EXISTING OR EQUALP-804 NONO
PUBLIC
PRIVATE PUBLIC
WALL HUNG BACK OUTLET TOILET WITH 1000 LB BARIATRIC CARRIER AND SENSOR FLUSH VALVE AMERICAN STANDARD NO. 3351.660 MOUNTED AT ADA HIEGHT OR EQUALBARIATRIC WALL HUNG WATER CLOSET
COUNTER VITEROUS CHINA LAVATORY
P-604 1/2"1-1/2"2"WALL HUNG SINGLE WATER COOLER WALL HUNG WATER COOLER WITH BOTTLE FILLER ELKAY MODEL NO. EZS8WSLK OR EQUAL0.71 NOYES
P-608 1/2"1-1/2"2"WALL HUNG DUAL WATER COOLER ADA DUAL HEIGHT WALL HUNG WATER COOLER WITH BOTTLE FILLER ELKAY MODEL NO. EZSTL3WSSK OR EQUAL0.71 NOYES
PUMP SCHEDULE
MARK DESCRIPTION
GPM HEAD (FT) HP RPM
PUMP CHARACTERISTICS
VOLT
502C-DWCP-1 DOMESTIC COLD WATER CIRCULATION PUMP
BASIS OF DESIGN OR EQUAL MANUFACTURER AND MODEL NUMBER
10 10 1/12
PH HZ
603450 115 11
1/12 3450 115502C-DWCP-2 DOMESTIC COLD WATER CIRCULATION PUMP 10 10 601
LEAD FREE, BRONZE IMPELLER, INLINE, CIRCULATION PUMP - BELL & GOSSETT PL-30 OR EQUAL
LEAD FREE, BRONZE IMPELLER, INLINE, CIRCULATION PUMP - BELL & GOSSETT PL-30 OR EQUAL
PLUMBING EQUIPMENT SCHEDULE
MARK DESCRIPTION
CHARACTERISTIC (EACH UNIT)
BASIS OF DESIGN OR EQUAL MANUFACTURER AND MODEL NUMBER
BFP-1 BACKFLOW PREVENTER LEAD FREE DOUBLE CHECK BACKFLOW PREVENTER AMES 2000SS OR EQUAL
GALLON CAPACITY
CW
4"
PRESSURE DROP
3 PSI 110 GPM
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402-391.8564
C U s e rs \k m m c in ty re
\D o c u m e n ts
\A u to d e s k \R e v it
P ro je c ts
\V A
M A
R T
M
E P
-F P k m m c in ty re
.r v t
/8 /2
:1
:0
P
M
PP701
PLUMBING SCHEDULES RENOVATE/EXPAND 47-BED
DOMICILIARY POD C AND REPLACE
AIR HANDLING UNITS
MARTI…
This is the start of the file's text. The full file is on GovTribe.