Question 20 nbrg8.pdf

PDF 1 MB Posted

Attached to
Z2QA--Renovate/Expand 47-Bed Domiciliary Pod C, Bldg 502 (VA-21-00039017)
Solicitation number
36C24521B0011
Issued by

About this file

This solicitation seeks a construction contractor to renovate and expand a 47-bed domiciliary pod at a Department of Veterans Affairs medical center in Martinsburg, West Virginia. The project includes complete renovation of an existing 17,600 square foot single-story domiciliary building that is 30 years old, including replacement of the HVAC system and updated finishes. An addition of 5,000 square feet will be constructed to increase occupancy. Asbestos abatement is also required. The estimated construction cost ranges from $5-10 million. The solicitation is restricted to Service Disabled Veteran Owned Small Businesses, and the selected contractor must hold the required construction licenses. The pre-bid site visit will be held on a date to be specified in the solicitation, which is planned for release on September 9, 2021. The anticipated bid opening is October 13, 2021 and award will be made to the responsive, responsible bidder offering the lowest price.

View the file

Other files

File Type Posted
36C24521B0011 0006.docx DOCX document
Question 18 arp.pdf PDF
Question 19 npodgfxform.pdf PDF
024100 Demolition.docx DOCX document
Asbestos Specs and Reports.zip ZIP file
36C24521B0011_1 - Revised 1-27-2022.docx DOCX document
36C24521B0011 0005.docx DOCX document
hrdw PB for M-WV.docx DOCX document
Pre-Bid RFIs Log -613-124 POD C 1-06-2022 SENT.xlsx XLSX spreadsheet
36C24521B0011 0004.docx DOCX document
36C24521B0011 0003.docx DOCX document
Pre-Bid Sign-In Sheet 12-21-2021.pdf PDF
613-124 Ren Exp 47-Bed Dom C Pod Repl AHUDwgs Vol IIArch Part 2.pdf PDF
613-124 Ren Exp 47-Bed Dom C Pod Repl AHUDwgs Vol IIArch Part 1.pdf PDF
36C24521B0011 0002.docx DOCX document
Pre-Bid Sign-In Sheet 12-07-2021.pdf PDF
Pre-Bid Sign-In Sheet 12-08-2021.pdf PDF
36C24521B0011_1.pdf PDF
36C24521B0011 0001.docx DOCX document
613-124 Ren Exp 47-Bed Dom C Pod Repl AHU_Dwgs Vol II_Arch Part 1.pdf PDF
613-124_Addendum No. 1.pdf PDF
613-124 Ren Exp 47-Bed Dom C Pod Repl AHU_ICRA ILSM.pdf PDF
613-124 Ren Exp 47-Bed Dom C Pod Repl AHU_Dwgs Vol II_Arch Part 2.pdf PDF
613-124 Ren Exp 47-Bed Dom C Pod Repl AHU_Specs.pdf PDF
36C24521B0011_1.docx DOCX document
613-124 Ren Exp 47-Bed Dom C Pod Repl AHU_Dwgs Vol I.pdf PDF
Wage Determination.pdf PDF
Drawings Volume II Part 1.pdf PDF
613-124 Ren Exp 47-Bed Dom C Pod Repl AHU_ICRA ILSM.pdf PDF
613-124 Ren Exp 47-Bed Dom C Pod Repl AHU_Dwgs Vol III.pdf PDF
613-124 Ren Exp 47-Bed Dom C Pod Repl AHU_Contr Resp Postures.pdf PDF
Drawings Volume II Part 2.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com/nLight © 2014-2021 Acuity Brands Lighting, Inc. All rights reserved. Rev. 12/28/21 nBRG - TN-701 nBRG 8

Series Voltage Temp/Humidity Power Supply Buy America(n)1 nBRG 8 Bridge [blank] 120/277VAC

347 347VAC

[blank] Standard LT Low temp

[blank] Unit Only KIT Kit w/ power supply

[blank] Standard BAA Buy America(n) Act Compliant

OVERVIEW

The nLight Bridge increases the number of lighting control zones in an nLight system. This ability stems from the fact that each Bridge has 8 RJ-45 ports into which zones of daisy-chained nLight devices can connect. The Bridge also is an integral component of the communication backbone in an nLight network. Fundamentally, Bridges act as hubs by aggregating traffic from the connected downstream zones and placing it onto the backbone. They also act as routers by forwarding information from the backbone out to the applicable downstream zones.

FEATURES

• Communicates with nLight Network

• Remotely configurable/upgradeable

• Push-button programmable

• Green LED indicators for each Port

• Redistributes bus power between ports

• Supports up to 128 devices per port nBRG 8 8-Port nLight Bridge

ORDERING INFORMATION

Catalog Number: Date: Project:

Capable This item is an A+ capable component, which has been designed and tested to provide out-of-the-box luminaire compatibility with simple commissioning, when included as part of an A+ Certified™ Solution.

To learn more about A+, visit www.acuitybrands.com/aplus.

Buy American BAA variants of this product are assembled in the USA and meet the Buy America(n) government procurement requirements under FAR, DFARS and DOT. Please refer to www.acuitybrands.com/buy-american for additional information.

Warranty Five-year limited warranty. Complete warranty terms located at:

www.acuitybrands.com/support/warranty/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application.

Specifications subject to change without notice.

Notes:

1. Not available with 347, LT, or KIT options.

Buy American http://www.acuitybrands.com/aplus http://www.acuitybrands.com/buy-american http://www.acuitybrands.com/support/warranty/terms-and-conditions nBRG - TN-701

PROGRAMMING

Refer to included instructions on LED indications and push button functionality.

RED

BLK

H

PS 150

WHT

BLK/ORN

N 120 V 277 V

BLK

ORN

A 15-24 VDC or VAC power supply can deliver power to the Bridge via the terminal connections on the side of the unit.

The PS 150 version power supply (included in the KIT option) is recommended, as it conveniently mounts through a knock-out on the side of the junction box where the Bridge unit is mounted.

1. Mount power supply to a 4” x 4” square junction box (through a 1/2” knockout)

2. Connect the power supply’s class 1 line voltage wires. Cap any unused wires.

3. Mount Bridge unit to top of same junction box

4. Connect the power supply’s low voltage wires to the Bridge’s terminal connectors. Upon power up, unit’s LEDs will flash.

5. Attach CAT-5e cables from lighting zones to the appropriate Bridge RJ-45 ports according to system design. Individual port

LEDs will blink according to the following pattern:

• Rapid Flash - Port is in discovery

• 1 Blink - Healthy zone of devices

• 2 Blinks - Upstream bridge or gateway is detected

• 4 Blinks - Downstream bridge is detected

6. Fill out Bridge’s port identification sticker(s) and commissioning card

POWER TERMINAL

CONNECTION

RJ-45 PORTLEDBUTTON SCREW HOLES

Cap unused BLK/ORN wire

DETAILED DIAGRAM

INSTALLATION

WIRING (DO NOT WIRE HOT)

NETWORK CONFIGURATION

An nLight network backbone consists of one or more Bridges and a Gateway (nGWY2 CTRL & nGWY2 GFX) communicating over CAT-5e wired connections. The architecture can be topology-free, however wide branching backbone networks are recommended over linear runs. Any one or more RJ-45 ports on a Bridge may be used to connect to other Bridge or Gateway devices.

Note: A maximum of 9 bridges may be used in a row (ie: bridge jumps from the gateway to the last bridge should remain less than 9).

3 44 5 6 5 6 7

1 21 2 3

5 6 7

1 2 3 4 nGWY2 GFX

SENSORVIEW

nBRG 8 nBRG 8 nBRG 8

LAN

nGWY2 CTRL

Serial #

Commisioning Card nBRG - TN-701

Electrical Input Ratings 15-24VDC, 60mA, Class 2 (via included PS-150 or PS-150-347 power supply with KIT option) 15-24VDC, 40mA, Class 2 per port (e.g. from a connected nPP16)

Low Voltage Output Ratings 15VDC, 40mA per RJ-45 Port (90mA total with connected PS-150 or PS-150-347 power supply)

Standards/ Ratings Energy Management Equipment, UL916 (E167435)

Mechanical Dimensions 4.90H” x 4.90W”x 1.05D” (124mm x 124mm x 27mm)

Mounting Directly to 4” x 4” Square Box Surface Mount

Color White Connection Type RJ-45 nLight Network Ports (8)

Low-Voltage Terminals

Environmental Warrantied Operating Temperature Standard: 32°F to 140°F (0°C to 60°C) LT option: -4°F to 140°F (-20°C to 60°C)

Relative Humidity Up to 90%, Non-Condensing Standards/ Ratings RoHS, Plenum UL2043

General Standards/ Ratings System Component to aid in compliance with Title 24, ASHRAE 90.1, IECC

Security Complies with California Civil Code Title 1.81.26, Security of Connected Devices, approved under Senate Bill No.327 (2018)

SPECIFICATIONS