6_Technical_Exhibit_145027-26-0030.pdf
PDF 4 MB Posted
- Solicitation number
- 1305M326Q0317
About this file
This is a Limited Hazardous Materials Survey report for NOAA Hangar 32 located at 7600 Sand Point Way NE, Seattle, Washington, prepared by EHS-International, Inc. (EHSI) in April 2022. The survey was conducted to identify asbestos-containing materials (ACM), regulated metals-containing paint (RCRA-8), polychlorinated biphenyl (PCB)-containing materials, mercury-containing items, and other hazardous materials within the building complex to support project planning for upcoming renovation work. The facility consists of three structures: North Lean-To (17,600 SF), Center Hangar (73,600 SF), and South Lean-To (11,200 SF), spanning four stories with multiple interior spaces and operational machinery areas.
The survey identified significant quantities of asbestos-containing materials throughout the facility, including approximately 2,500 SF of vinyl asbestos tile (VAT) with black mastic, 3,700 SF of additional VAT with black mastic beneath non-ACM carpet, 8,750 SF of flat transite panels on interior walls, 7,500 SF of corrugated transite panels on exterior, 11,200 SF of joint compound on gypsum wallboard, and 16,000 lineal feet of window frame glazing and caulking. Additional ACM includes 1,500 LF of thermal system insulation on piping, 3,000 LF of window edge caulking, 1 EA of 12" diameter steam tank gasket containing 45% chrysotile, and various miscellaneous items. EHSI collected 189 bulk samples with 10 quality assurance splits using polarized light microscopy analysis. Paint chip sampling identified detectable levels of arsenic, barium, cadmium, chromium, mercury, and lead across multiple surfaces. The survey also inventoried 110 potential mercury-containing fluorescent light tubes, 45 potential PCB-containing light ballasts, 3 stand-alone refrigerator/freezer units with CFCs, 2 walk-in freezers with CFCs, 10 mercury-containing thermostats, and 4 transformers. The report recommends that an asbestos abatement contractor licensed under WAC 296-62-077 and PSCAA Regulation III, Article 4 remove all ACM prior to demolition, and provides comprehensive guidance on lead paint handling, PCB ballast management, and mercury-containing material disposal in accordance with Washington State regulations.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
• Environmental Consulting
• Hazardous Materials Management
• Industrial Hygiene Services
• Construction Management
• Indoor Air Quality
Limited Hazardous Building Material Survey
WRC Building 32
National Oceanic and Atmospheric Administration (NOAA) 7600 Sand Point Way NE
Seattle, Washington
EHSI Project No. 11527
Prepared for:
F. Mark Adolphsen Principal-In-Charge, AKS Architecture 1124 NW 50th Street, Seattle, WA 98107
Prepared by:
EHS-International, Inc.
1011 Southwest Klickitat Way, Suite 104 Seattle, Washington 98134
206-381-1128
Sunny Joshi
Project Manager
Fred Luck
Principal
April 2022
Technical Exhibit 6
PROJECT INFO:
HAZARDOUS MATERIALS SURVEY
HANGAR 32 SHELL & CORE NOAA WESTERN REGIONAL CENTER
7600 SAND POINT WAY NE
SEATTLE, WA
AKS PS, INC
SEATTLE, WA
SURVEY DATES:
S. JOSHI
PROJECT MANAGER:
F. DIMALANTA
DRAWN BY:
INSPECTORS: ISSUE DATE: EHSI PROJECT #
11527-01
SCALE: SHEET
1011 SW Klickitat Way, Suite 104 Seattle, Washington 98134 Ph: 206.381.1128 Fax: 206.254.4279
LEGEND: DRAWING TITLE:
S. JOSHI
M. MACFARLANE
11/10/21
SL-1
NTS
FIRST FLOOR PLAN
SOUTH
11527-XX BULK ASBESTOS SAMPLE LOCATIONS
NORTH
11527-TCLPXX BULK TCLP SAMPLE LOCATIONS
1. DRAWING IS SCHEMATIC AND SAMPLE LOCATIONS ARE
APPROXIMATE.
2. REFER TO REPORT FOR MORE INFORMATION ABOUT THE SAMPLED
MATERIALS.
3. BACKGROUND DRAWING WAS PREPARED BASED ON SKETCHES
PREPARED IN THE FIELD.
ROOM IDENTIFIER
11527-MXX BULK PCB/RCRA 8 SAMPLE LOCATIONS
11527-168 11527-153
11527-172
11527-143 11527-144 11527-145
11527-148
11527-147
11527-130
11527-89 11527-124
11527-126
11527-125
11527-88 11527-116
11527-117 11527-118 11527-92 11527-99 11527-106
11527-103
11527-TCLP03
11527-91
11527-100 11527-101
11527-105
11527-115 11527-114 11527-134 11527-135 11527-137
11527-136 11527-138
11527-141
11527-93
11527-132 11527-127
11527-86
11527-129
11527-M07
11527-M08
11527-149 11527-17
11527-128
11527-154
11527-169
11527-150
11527-152
11527-119
11527-170
11527-151
11527-155
11527-120
11527-173
11527-146
11527-121
11527-131
11527-110 11527-112 11527-113
11527-107 11527-108 11527-109 11527-11111527-104
11527-139 11527-140
11527-142
11527-133
11527-87
KEY PLAN
11527-109
11527-186
11527-185 11527-183
11527-184
11527-187
11527-188
11527-M11
11527-197
11527-196
10/25/21-10/29/21 11/01/21-11/05/21 12/06/21
11527-172 /73
Areas of scope highligted
CLIN 004
CLIN 005
CLIN 003
TRANSITE (ACM)
WALL
VITREOUS CHINALAVATORYGREENWICHK-2031
VITREOUS CHINALAVATORYGREENWICHK-2031
VITREOUS CHINALAVATORYGREENWICHK-2031
PROJECT INFO:
HAZARDOUS MATERIALS SURVEY
HANGAR 32 SHELL & CORE NOAA WESTERN REGIONAL CENTER
7600 SAND POINT WAY NE
SEATTLE, WA
AKS PS, INC
SEATTLE, WA
SURVEY DATES:
S. JOSHI
PROJECT MANAGER:
F. DIMALANTA
DRAWN BY:
INSPECTORS: ISSUE DATE: EHSI PROJECT #
11527-01
SCALE: SHEET
1011 SW Klickitat Way, Suite 104 Seattle, Washington 98134 Ph: 206.381.1128 Fax: 206.254.4279
LEGEND: DRAWING TITLE:
S. JOSHI
M. MACFARLANE
11/10/21
SL-2
NTS
FIRST FLOOR PLAN
NORTH
NORTH
1. DRAWING IS SCHEMATIC AND SAMPLE LOCATIONS ARE
APPROXIMATE.
2. REFER TO REPORT FOR MORE INFORMATION ABOUT THE SAMPLED
MATERIALS.
3. BACKGROUND DRAWING WAS PREPARED BASED ON SKETCHES
PREPARED IN THE FIELD.
11527-17
11527-18
11527-44
11527-63
11527-19 11527-20 11527-60
11527-61
11527-59
11527-85
11527-M04 11527-42
11527-13
11527-84
11527-14
11527-43
11527-10
11527-83
11527-09
11527-11
11527-12
11527-82
11527-M06
11527-03 11527-01
11527-07
11527-06
11527-TCLP01
11527-21
11527-90
11527-38
11527-04
11527-02
11527-05
11527-39
11527-M05
11527-TCLP02
11527-58
11527-44
11527-40
11527-16
11527-15
11527-45
11527-22 11527-23
11527-64
11527-62
11527-08
KEY PLAN
11527-XX BULK ASBESTOS SAMPLE LOCATIONS
11527-TCLPXX BULK TCLP SAMPLE LOCATIONS
ROOM IDENTIFIER
11527-MXX BULK PCB/RCRA 8 SAMPLE LOCATIONS
11527-M09 11527-M10
11527-192
10/25/21-10/29/21 11/01/21-11/05/21 12/06/21
1127-10QA
CLIN 002 & 006-OPTIONAL
CLIN 001
TRANSITE (ACM)
WALL
HANGAR 32 SHELL & CORE NOAA WESTERN REGIONAL CENTER
7600 SAND POINT WAY NE
SEATTLE, WA
AKS PS, INC
SEATTLE, WA
SURVEY DATES:
S. JOSHI
PROJECT MANAGER:
F. DIMALANTA
DRAWN BY:
INSPECTORS: ISSUE DATE: EHSI PROJECT #
11527-01
SCALE: SHEET
1011 SW Klickitat Way, Suite 104 Seattle, Washington 98134 Ph: 206.381.1128 Fax: 206.254.4279
LEGEND: DRAWING TITLE:
S. JOSHI
M. MACFARLANE
11/10/21
SL-3
NTS
SECOND FLOOR PLAN
SOUTH
11527-XX BULK ASBESTOS SAMPLE LOCATIONS
NORTH
1. DRAWING IS SCHEMATIC AND SAMPLE LOCATIONS ARE
APPROXIMATE.
2. REFER TO REPORT FOR MORE INFORMATION ABOUT THE SAMPLED
MATERIALS.
3. BACKGROUND DRAWING WAS PREPARED BASED ON SKETCHES
PREPARED IN THE FIELD.
ROOM IDENTIFIER
11527-102
11527-179
11527-98
11527-97
11527-174
11527-76
11527-178
11527-164
11527-166
11527-165
11527-176
11527-95
11527-94
11527-167
11527-177 KEY PLAN
11527-193
10/25/21-10/29/21 11/01/21-11/05/21 12/06/21
11527-172/73
11527-172/73
CLIN 005 PANEL JJ
CLIN 004 PANEL II
HANGAR 32 SHELL & CORE NOAA WESTERN REGIONAL CENTER
7600 SAND POINT WAY NE
SEATTLE, WA
AKS PS, INC
SEATTLE, WA
SURVEY DATES:
S. JOSHI
PROJECT MANAGER:
F. DIMALANTA
DRAWN BY:
INSPECTORS: ISSUE DATE: EHSI PROJECT #
11527-01
SCALE: SHEET
1011 SW Klickitat Way, Suite 104 Seattle, Washington 98134 Ph: 206.381.1128 Fax: 206.254.4279
LEGEND: DRAWING TITLE:
S. JOSHI
M. MACFARLANE
11/10/21
SL-4
NTS
SECOND FLOOR PLAN
NORTH
11527-XX BULK ASBESTOS SAMPLE LOCATIONS
NORTH
1. DRAWING IS SCHEMATIC AND SAMPLE LOCATIONS ARE
APPROXIMATE.
2. REFER TO REPORT FOR MORE INFORMATION ABOUT THE SAMPLED
MATERIALS.
3. BACKGROUND DRAWING WAS PREPARED BASED ON SKETCHES
PREPARED IN THE FIELD.
ROOM IDENTIFIER
11527-65
11527-57
11527-68
11527-56
11527-54
11527-55
11527-35
11527-51
11527-46
11527-50
11527-34
11527-27
11527-26
11527-32 11527-30 11527-29 11527-49
11527-72
11527-28
11527-48
11527-70
11527-36
11527-31
11527-25
11527-33
11527-37
11527-71
11527-69
11527-47
KEY PLAN
11527-194
11527-195
10/25/21-10/29/21 11/01/21-11/05/21 12/06/21
11527-172&173
CLIN 002 PANEL HH
AREA A
NOT TO SCALE
PROJECT INFO:
HAZARDOUS MATERIALS SURVEY
HANGAR 32 SHELL & CORE NOAA WESTERN REGIONAL CENTER
7600 SAND POINT WAY NE
SEATTLE, WA
AKS PS, INC
SEATTLE, WA
SURVEY DATES:
S. JOSHI
PROJECT MANAGER:
F. DIMALANTA
DRAWN BY:
INSPECTORS: ISSUE DATE: EHSI PROJECT #
11527-01
SCALE: SHEET
1011 SW Klickitat Way, Suite 104 Seattle, Washington 98134 Ph: 206.381.1128 Fax: 206.254.4279
LEGEND: DRAWING TITLE:
10/25/21-10/29/21 11/01/21-11/05/21 12/06/21
S. JOSHI
M. MACFARLANE
11/10/21
SL-6
NTSFOURTH FLOOR PLAN
11527-XX BULK ASBESTOS SAMPLE LOCATIONS
NORTH
1. DRAWING IS SCHEMATIC AND SAMPLE LOCATIONS ARE
APPROXIMATE.
2. REFER TO REPORT FOR MORE INFORMATION ABOUT THE SAMPLED
MATERIALS.
3. BACKGROUND DRAWING WAS PREPARED BASED ON SKETCHES
PREPARED IN THE FIELD.
ROOM IDENTIFIER
KEY PLAN
AREA E
NOT TO SCALE
AREA B
NOT TO SCALE
11527-156 11527-157 11527-158
11527-162
11527-163
11527-81
11527-79
11527-190
Limited Hazardous Materials Survey – AKS Architecture NOAA Hangar 32 i
EXECUTIVE SUMMARY
AKS Architecture has contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene consulting firm, to conduct a Limited Hazardous Materials Survey of AKS NOAA Hangar 32 located at 7600 Sand Point Way NE, Seattle, Washington (Site). EHSI understands that the survey will be used in project planning for upcoming renovation of the Site.
The limited hazardous materials survey included asbestos-containing materials (ACM); regulated-metals-containing paint (RCRA-8); polychlorinated biphenyl (PCB)-containing paint, light ballasts, and bulk materials; mercury-containing fluorescent light tubes, freezers/fridges, and thermostats; and other regulated materials. This survey was performed in accordance with federal, state, and local regulatory requirements. Each regulated material included in the survey is summarized below.
Previous Reports
EHSI reviewed the following reports in preparation for this survey:
• Raven Services Corporation – Asbestos Management Report, 1/20/98
• Unknown – NOAA WRC ACBM Location CAD Interior 2/24/20
• Ahtna Global, LLC – Good Faith Survey, Hangar 32 Reroofing, 3/17/21
Asbestos-Containing Building Materials
EHSI collected one hundred eighty-nine (189) bulk samples of suspect ACM at the Site along with an additional ten (10) quality assurance samples. Many of those samples were found to contain asbestos, while other materials that could not be sampled were assumed to contain asbestos. Several of the materials sampled that do not contain asbestos are adhered to ACM and must also be assumed to be contaminated with asbestos in the event those materials are removed or disturbed during demolition.
Specific sample locations of the suspect materials can be referenced in sample location figures SL-1 through SL-6.
The following summary of ACMs and assumed ACMs were identified by EHSI sampling.
• 2,500 Square Feet (SF) – ACM Vinyl asbestos tile (VAT) (multiple sizes/colors) on ACM mastic (black) on concrete throughout
• 3,700 SF – ACM VAT (tan/gray/green) with ACM mastic (black) beneath various non-ACM carpet flooring and non-ACM mastic on concrete throughout
• 3,725 SF – ACM Black Mastic beneath various non-ACM carpets/tiles, on concrete throughout
• 8,750 SF – Flat Transite Panels on walls interior of hangar
• 7,500 SF – Corrugated Transite Panels on exterior of hangar (quantity not given in cost estimate)
• 11,200 SF – Joint Compound on Gypsum Wallboard (GWB), with white paint (<1%)
• 1,650 SF – White Skim Coat on corner joints of door/window frames
• 16,000 Lineal Feet (LF) – White/brown window frame glazing around edges of windowpanes on exterior
• 3,000 LF – White window edge frame caulking, between windows/doors and transite on exterior
• 1,500 LF – ACM Thermal System Insulation (TSI) on piping 8” or less
• 150 SF – ACM black countertops, resting atop tan metals shelves
• 1 EA - 12” Diameter– ACM black steam tank gasket ii
• 54 LF – ACM brown window frame caulking, inside windows in two locations
• 20 EA – ACM white window glazing, interior in one room
• 68 LF – ACM yellow toilet caulking, present in restrooms
• 4 EA – ACM electrical panels with Cement Asbestos Board (CAB) backer and interior components
• 20 EA – ACM electrical junction boxes with Cement Asbestos Board (CAB) backer and interior components (multiple sizes throughout)
Hazardous Metals-Containing Paint
EHSI completed a limited HMCP assessment of the proposed work area and specific materials expected to be impacted through the collection and analysis of eleven (11) paint chip samples. Detectable levels of
Arsenic (As), Barium (Ba), Cadmium (Cd), Chromium (Cr), Mercury (Hg), and Lead (Pb) were found in the paint chip samples analyzed as a part of this limited hazardous building material survey.
The US Occupational Safety and Health Administration (OSHA) requires employers to conduct a hazard assessment and take appropriate worker protection precautions whenever building materials are disturbed that have detectable quantities of hazardous metals. EHSI recommends that the provided paint chip sample results be used in conjunction with other applicable (e.g., air monitoring) data to evaluate the potential for elevated occupation lead and RCRA 8 metal exposures during demolition activities.
Polychlorinated Biphenyl Light Ballasts, Mercury, and Other Regulated Materials
As part of our survey for regulated materials, EHSI quantified the number of light ballasts and prepared an inventory of other installed regulated materials that may classify as universal hazardous wastes or other regulated wastes. These materials included PCB-containing paint, mercury-containing items such as fluorescent light tubes, high-intensity discharge lighting, thermostats, and switches. All identified magnetic ballasts are assumed to contain PCBs. A similar assumption applies to mercury potentially present within fluorescent lamps and fluorescent light fixtures. Generally, it is not necessary to sample these materials because their presence within the building represents a future cost for disposal of the facility’s installed contents.
The following regulated materials were identified at throughout Site described below:
• Potential mercury-containing fluorescent light tubes: 110 EA
• Potential PCB-containing light ballasts: 45 EA
• Stand-Alone refrigerator freezer or chest freezer with CFC units: 3 EA
• Walk-In freezers/coolers with CFC units: 2 EA
• Mercury-containing Thermostats: 10 EA
• PCB-containing paint: Throughout (see tables for exact paint colors) iii
TABLE OF CONTENTS
EXECUTIVE SUMMARY
INTRODUCTION
1.1 SCOPE OF WORK
1.2 BUILDING DESCRIPTION
1.3 LIMITATIONS
METHODOLOGY
2.1 ASBESTOS SURVEY METHODOLOGY
2.1.1 Previous Reports
2.1.2 Sample Documentation
2.1.3 Laboratory Analysis
2.2 LEAD SURVEY
2.2.1 Sample Documentation
2.2.2 Laboratory Analysis
2.3 Arsenic Survey
2.3.1 Sample Documentation
2.3.2 Laboratory Analysis
2.4 VISUAL SURVEY OF PCBS, MERCURY, AND OTHER REGULATED MATERIALS
RESULTS
3.1 ASBESTOS
3.2 METALS
3.3 PCBS, MERCURY, AND OTHER REGULATED MATERIALS
CONCLUSIONS AND RECOMMENDATIONS
4.1 ASBESTOS-CONTAINING MATERIALS
4.2 LEAD PAINT
4.3 Arsenic
4.4 PCBS, MERCURY, AND OTHER REGULATED MATERIALS
4.4.1 Polychlorinated Biphenyl Light Ballasts
4.4.2 Mercury
APPENDICES
Appendix A, Inspector Certifications Appendix B, Laboratory Analytical Reports and Chain-of-Custody Forms Appendix C, Laboratory Certifications Appendix D, Photo Log
INTRODUCTION
AKS Architecture has contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene consulting firm, to conduct a Limited Hazardous Materials Survey of AKS NOAA Hangar 32 located at 7600 Sand Point Way NE, Seattle, Washington (Site). EHSI understands that the survey will be used in project planning for upcoming renovation of the Site.
The limited hazardous materials survey included asbestos-containing materials (ACM); regulated-metals-containing paint (RCRA-8); polychlorinated biphenyl (PCB)-containing paint, light ballasts, and bulk materials; mercury-containing fluorescent light tubes, freezers/fridges, and thermostats; and other regulated materials. This survey was performed in accordance with federal, state, and local regulatory requirements. Each regulated material included in the survey is summarized below.
1.1 Scope of Work
The scope of services for the limited hazardous materials survey included the following tasks:
• Collect bulk suspect ACM samples as necessary to identify ACM within the Site building. Where bulk sampling or access is not possible, review available historical drawings and make inventory assumptions to the likely quantities of ACM that can be assumed.
• Collect limited LCP chip samples of common color paints on representative building components and have them analyzed for lead.
• Inventory universal wastes such as potential PCB-containing lighting ballasts; mercury-containing fluorescent light tubes; high pressure sodium lamps; mercury-containing fluorescent light tubes, switches, and thermostats.
• Prepare a summary report documenting the findings of the survey and provide tables summarizing hazardous materials, analytical data, comments and recommendations for handling and control.
1.2 Building Description
The following is a listing of the areas (units) that are found at the Site and are further shown on Figure SL, overall site plan.
• North Lean-To
• Center Hangar
• South Lean-To
Both Lean-To’s are four (4) stories high, with the third and fourth floors being primarily comprised of a stairwell and a single room at each corner of the building. The South Lean-To has a gross square footage of approximately 11,200 square feet. The North Lean-To is nearly identical in structure except for an additional interior, for a gross total of 17,600 square feet. Between both Lean-To’s is the Center Hangar, a mostly open area containing several storage structures and various operational machinery, with a gross square footage of 73,600 square feet.
1.3 Limitations
The conclusions of the report are professional opinions based solely upon visual site observations, and interpretations of sample analyses as described in this report. The opinions presented herein apply to conditions existing at the time of the investigation, and interpretation of current regulations pertaining to
ACMs. Therefore, opinions and recommendations provided herein might not apply to future conditions that may exist at the Site. Current applicable regulations should always be verified prior to any work involving asbestos or other regulated materials. This survey is not intended to be used as an abatement design document. All existing conditions, quantities, and locations should be verified prior to abatement.
ACM may be located within areas that were not accessible during this survey. The survey did not include an investigation of potentially buried piping within or in the vicinity of the structures.
The purpose of the limited hazardous material survey is to reasonably test for evidence of asbestos and other hazardous materials in suspect or randomly selected materials at a facility. It should be noted that no survey can be comprehensive or exhaustive enough to eliminate the possibility that ACM present at the Site may not be detected during the survey. Therefore, the completion of this or any survey for ACM or other hazardous materials should not be considered a warranty or guarantee that these materials do not exist, even if they are not detected through a survey.
The survey did not include sampling of the following materials or locations at the Site due to limited access:
• Materials associated with energized electrical equipment (e.g., wiring and panel boards) and transformers
• Buried piping
• Gaskets or packing materials in closed equipment
• Built-up roofing system
Due to the age of the buildings on the Site, it is possible that materials associated with the above-noted structures/systems may be asbestos-containing. If suspect materials are determined to be present within the above-noted systems, the materials should be considered as presumed ACMs until proven otherwise by sampling and laboratory analysis.
METHODOLOGY
Information concerning the Site was obtained from site inspections conducted by EHSI employees including Mr. Sunny Joshi and Mr. Matt Macfarlane. Copies of their AHERA building inspector certifications are included in Appendix A. This section describes the sampling methodology and applicable asbestos regulations.
2.1 Asbestos Survey Methodology
A visual inspection of accessible areas was conducted to identify suspect ACM and assumed ACM. The asbestos survey was performed by AHERA-certified building inspectors in accordance with a sampling protocol appropriate for the demolition of the Site building. The sampling protocol was developed in accordance with the following:
• U. S. Environmental Protection Agency (EPA) Asbestos Regulation within the Toxic Substances Control Act (40 Code of Federal Regulation [CFR] 763)
• Puget Sound Clean Air Agency (PSCAA) Asbestos Control Standards (Regulation III, Article 4), and
• Washington State Department of Labor and Industries Asbestos, Tremolite, Anthophyllite, and Actinolite Regulation (WAC 296-62-077).
The sampling plan included, at a minimum, the collection and analysis of samples as follows:
• Thermal system insulation (TSI): EHSI collected a minimum of three samples in a distributive manner from each homogeneous sampling area not presumed to contain asbestos. At least one bulk sample of patched TSI was collected from each homogenous area, if the patch was less than 6 square feet in area.
• Surfacing material: EHSI collected a minimum of three samples in a distributive manner from each homogenous area that was 1,000 square feet or less in area. A minimum of five samples were collected from each homogenous area that was more than 1,000 square feet but less than or equal to 5,000 square feet in area. A minimum of seven samples were collected from each homogenous area that was more than 5,000 square feet in area.
• Miscellaneous material: EHSI collected bulk samples of suspect ACM in a distributive manner as deemed sufficient by the AHERA-certified building inspector. At least one sample was collected of each suspect miscellaneous material not presumed to contain asbestos.
• Non-suspect materials: According to 40 CFR 763-86(4), where the accredited inspector has deemed the material to be fiberglass, foam glass, rubber, or other recognized non-ACM, sampling is not required.
Samples were collected by carefully removing small portions of the suspect material with a sharp knife or other hand tool suitable for the material being sampled. The sampling instrument was wiped with a clean moist cloth to decontaminate the tool and minimize the potential release of asbestos fibers or cross-contamination of subsequent samples. Once collected, each bulk sample was sealed in a new clean plastic bag to eliminate the possibility of cross-contamination, labeled with the sample name, and shipped to the analytical laboratory under standard chain-of-custody protocols. Bulk ACM sample locations are illustrated in Figures SL-1 through SL-22.
2.1.1 Sample Documentation
A unique sample identification system was employed for bulk samples of suspect ACMs collected during the survey that includes the project number, and sample sequence number.
Example: 11527-A - 001QA
Data pertinent to each sample (e.g., date, sample name, material description, and material category) was recorded on a field data sheet. The material determination of friability was made by the AHERA-certified building inspector in the field. Details regarding the bulk samples of suspect ACMs and their friability are summarized in Table 1.
2.1.2 Laboratory Analysis
As specified in 40 CFR 763.87, each sample was analyzed using polarized light microscopy (PLM) with dispersion staining in accordance with EPA Method 600/R-93/116. Samples were analyzed for asbestos
EHSI Project Number Sample Sequence Number
“QA” added on designated quality assurance samples only
Unit Name content by Seattle Asbestos Test, LLC (SAT) in Seattle, Washington. SAT participates in the National
Institute for Standards and Technology National Voluntary Laboratory Accreditation Plan (NVLAP). Only materials containing greater than 1% total asbestos were classified as “asbestos-containing” based on
EPA, state, and local regulations.
Split samples were collected from some same locations for the purposes of quality assurance (QA) and sent to a separate laboratory for analysis. QA samples were submitted to NVL Laboratories, Inc. (NVL) in
Seattle, Washington. NVL is also a NVLAP-accredited laboratory.
Laboratory analytical reports and chain-of-custody forms are provided in Appendix B. Laboratory certifications are provided in Appendix C.
2.2 RCRA Metals Survey
EHSI collected bulk samples to determine the RCRA Metals content of interior and exterior painted coatings. Once collected, each bulk sample was sealed in an unadulterated plastic bag to eliminate the possibility of cross-contamination. “Chain-of-Custody” tracking was followed to maintain sample integrity during handling and data reporting at EHSI and the analytical laboratory. The bulk samples were taken for a representative number of LBP and LCM and were sent to NVL located in Seattle, Washington, an accredited laboratory.
2.2.1 Sample Documentation
A unique sample identification system was employed for paint chip samples that included the project number, chemical abbreviation for lead, and sample sequence number.
Example:
11527-M01
2.2.2 Laboratory Analysis
The paint chip samples were analyzed in accordance with EPA Method 3051/7000B by NVL. NVL participates in the National Environmental Laboratory Accreditation Program and employs American
Industrial Hygiene Association quality control procedures.
A summary of bulk lead paint results is provided in Table 10. Laboratory analytical reports and chain-of-custody forms are provided in Appendix B. Laboratory certifications are provided in Appendix C.
2.3 PCB Survey
The PCB survey consisted of EHSI collecting a minimal number of representative suspect samples. EHSI collected twelve (11) samples during the limited hazardous building material survey. Mortar samples were obtained by using a chisel to break off a corner of BMU or CMU with mortar. Approximately ½ cubic inch of mortar was removed for each sample. Samples were then placed into 2-ounce, puncture-proof, polyethylene bags, labeled with sample name, and placed in a box for shipping to the analytical laboratory
EHSI Project Number RCRA Paint Identifier
Sample Sequence Number under standard chain-of-custody protocols. The sampling chisel was cleaned to reduce the possibility of cross-contamination between sample locations.
2.3.1 Sample Documentation
A unique sample identification system was employed for mortar samples that included the project number, chemical abbreviation for lead, and sample sequence number.
Example:
11527-MS01
2.3.2 Laboratory Analysis
The mortar samples were analyzed in accordance with EPA Method 3051/6010D by NVL. NVL participates in the National Environmental Laboratory Accreditation Program and employs American Industrial
Hygiene Association quality control procedures.
A summary of bulk arsenic results is provided in Table 11. Laboratory analytical reports and chain-of-custody forms are provided in Appendix B. Laboratory certifications are provided in Appendix C.
2.4 Visual Survey of PCBs, Mercury, and Other Regulated Materials
Verifying the presence or absence of PCBs, mercury, or other regulated materials by laboratory analysis, was beyond the scope of this survey. The survey did include visual identification and determination of quantities of potentially PCB-containing fluorescent light ballasts or transformers. All the ballasts were assumed to contain PCBs. A similar assumption applies to mercury potentially present within fluorescent lamps in fluorescent light fixtures, high intensity discharge (HID) lamps, and thermostats.
RESULTS
This section summarizes the results of the limited hazardous building material survey conducted at the
Site.
3.1 Asbestos
The following ACMs or assumed ACMs were identified at the Site, described below. All quantities are approximate.
North Lean-To
• 1,500 Lineal Feet (LF) – ACM White window edge frame caulking (between window frames/door frames & transite)
• 3000/8000 SF/LF – ACM White/brown window frame glazing (around edges of windowpanes)
• 1,350 SF – ACM 9”x9” VAT (black) with ACM mastic (black) on concrete throughout
• 500 SF – ACM mastic (black) on ACM 12”x12” VCT (black) w/ ACM mastic (black) under non-ACM carpet squares (green) on concrete, Room 101
EHSI Project Number
Sample Sequence Number
PCB Sample Identifier
• 120 SF – ACM joint compound (white) on gypsum wallboard (GWB), Room 101
• 34 LF – ACM toilet caulking (yellow), Rooms 200 & 230
South Lean-To
• 1,500 LF – ACM White window edge frame caulking (between window frames/door frames & transite), Exterior
• 3000/8000 SF/LF – ACM White/brown window frame glazing (around edges of windowpanes), Exterior
• 12” OD (1 EA) – ACM steam tank gasket w/ paint (black), Basement Trench
• 60 SF – ACM countertop (black) w/ non-ACM mastic (brown) on tan metal shelf, Rooms 133-134
• 34 LF – ACM toilet caulking (yellow), Rooms 132, 149, 266, & 288
A detailed summary of ACMs including the sample number, homogenous material description, material classification, analytical results, and quantity (for ACMs only) is provided in Table 1 through Table 8.
Copies of the analytical laboratory reports and chain-of-custody forms for bulk samples of suspect ACM are included in Appendix B. Bulk suspect ACM sample locations are illustrated on Figures SL-1 through
SL-6.
3.2 RCRA-8 (Total Metals and TCLP)
EHSI collected eleven (11) paint chip samples from the Site. Analysis of the paint chip samples shows detectable levels of Arsenic, Barium, Cadmium, Chromium, Mercury, and Lead. The paint chip analytical results are included in Tables 2 and 4. A copy of the laboratory analytical report and chain-of-custody form for RCRA/TCLP bulk samples are included in Appendix B.
3.3 PCB’s
EHSI collected twelve (11) paint chip samples from the Site. Analysis of the paint samples shows results below the limit of detection to detectable levels of 15.4 mg/Kg. The summary of PCB analytical results is included in Table 3.
A copy of the laboratory analytical report and chain-of-custody form for PCB samples are included in
Appendix B.
3.4 PCBs, Mercury, and Other Regulated Materials
A tabulated summary of fluorescent light ballasts, mercury-containing light tubes, HID lamps, fire alarm control panels with Lead-acid batteries, and thermostats are provided in Table 5.
CONCLUSIONS AND RECOMMENDATIONS
A copy of this report must be provided to any contractor bidding and/or conducting work at the Site. The contractor must also have a copy of this report during demolition activities at the Site. Conclusions and recommendations for each regulated material category are summarized below.
4.1 Asbestos-Containing Materials
ACMs were identified at AKS NOAA Hangar 32. An asbestos abatement contractor licensed in accordance with WAC 296-62-077 and PSCAA Regulation III, Article 4 must remove all asbestos-containing and asbestos contaminated building materials prior to demolition.
The contractor should also use caution when performing demolition activities within the project areas even after asbestos abatement activities have been conducted. Concealed materials may be encountered during a renovation or demolition project. ACM may be located between walls, in pipe chases, between pipe flanges or other inaccessible areas.
If additional suspect building materials not identified specifically in this report as either ACM or non-
ACM are identified during demolition activities, they should be treated as ACM until sampled by an
AHERA-certified building inspector and proven to not contain asbestos through laboratory analysis.
4.2 Lead Paint
Based on sampling results, EHSI recommends treating all painted surfaces as having paint with detectable concentrations of lead. The Washington State Department of Commerce defines LCP as coatings with a concentration of lead greater than or equal to 0.5 percent by weight. However, the U.S.
Department of Labor and the Washington State Department of Labor and Industries require that the
Washington State Construction Standards for Lead (WAC 296-155-176) be followed during “new construction, alteration, repair, or renovation of structures, substrates, or portions thereof that contain lead, or materials containing lead.” These standards consider any detectable concentration of lead to be a potential hazard during construction activities.
The Washington State Department of Labor and Industries considers any detectable concentration of lead to be a potential hazard during construction activities. Based on the limited testing of painted surfaces completed by EHSI, EHSI recommends assuming all painted surfaces in the project area contain at least detectable levels of lead. Most of the paint coatings were found to be in good condition. EHSI recommends that the contractor use precautions and follow applicable health and safety guidelines when removing materials during asbestos abatement activities, building renovation, or demolition.
For work on building components containing lead or other heavy metals, which may result in personnel exposures, the contractor must assess the hazard. Based on the assessment, and previous similar work and exposure monitoring results, the contractor may have to provide any or all the following for employees per WAC 296-155-176:
• Respiratory protection.
• Protective clothing.
• Clean change areas.
• Clean handwashing facilities.
• Biological monitoring to consist of blood sampling and analysis for lead and zinc protoporphyrin levels; and
• Hazard communication training.
Initial employee exposure monitoring must be conducted for each separate task involving the handling of LCP-coated building materials. If 8-hour time-weighted average exposures exceed the action level of
30 micrograms per cubic meter, the contractor must continue to conduct periodic air monitoring at specified intervals, and institute medical surveillance and comprehensive training programs. If the OSHA
8-hour time-weighted average permissible exposure limit of 50 micrograms per cubic meter of lead is exceeded, more stringent and additional requirements become effective, such as engineering controls, respiratory protection, regulated work areas and warning signs in lead work areas.
The general contractor performing demolition work should be informed of the presence of lead in the project area. All personnel impacting LCP (or other lead-containing materials) should be provided additional training concerning the health effects of lead, proper work methods, appropriate use of personal protective equipment, and regulations governing lead exposures. Air monitoring to assess lead exposures should be performed for all personnel involved in the demolition process where LCP may be removed.
4.3 PCBs, Mercury, and Other Regulated Materials
4.3.1 Polychlorinated Biphenyl Light Ballasts
The Washington State Dangerous Waste Regulation, WAC 173-303, designates that discarded transformers, capacitors, or bushings containing PCBs at concentrations of 2 parts per million or greater be treated as a PCB-containing material. Light ballasts fall under this regulation. Previous regulations dictated that any material with less than 50 parts per million of PCBs could be labeled as a non-PCB-containing material. Because of this regulatory change, EHSI recommends that all light ballasts be tracked, removed, handled, and disposed of in an appropriate manner. Ballasts with a label stating, “NO
PCB” (or something similar) shall be packaged for recycling by an approved recycling facility.
4.3.2 Mercury
Many fluorescent light tubes, HID lamps, thermostats, and switches contain mercury that is harmful to the environment and human health. The EPA and Washington State Department of Ecology have placed these materials in a special category of dangerous waste known as universal waste. Some of the requirements included within the Standards for Universal Waste Management (WAC 173-303-573) include:
• Immediately place lamps showing evidence of leakage, damage, etc. into a container following removal.
• Containerize in closed, structurally sound, compatible containers. Cardboard containers may be used for inside storage only.
• Labeling container as follows: “Waste Lamps,” or “Universal Waste Lamps”.
• Track the length of time since waste lamp generation. Acceptable methods of proof include date on label, inventory system, etc.
• Respond immediately to potential releases. If determined to be a release, contain, and determine if it designates as a dangerous waste.
• Disposal of universal waste as general or construction debris is not permitted.
• The crushing of fluorescent light tubes on-site is not allowed. In addition, measures should be taken to prevent breakage of fluorescent light tubes while the light tubes are in transit to their destination.
• Provide training to employees on the proper handling and emergency procedures for universal waste lamps.
• Track shipments of universal waste lamps with records (invoice, manifest, etc.) kept for a minimum of 3 years.
Figures
PROJECT INFO:
HAZARDOUS MATERIALS SURVEY
HANGAR 32 SHELL & CORE NOAA WESTERN REGIONAL CENTER
7600 SAND POINT WAY NE
SEATTLE, WA
AKS PS, INC
SEATTLE, WA
SURVEY DATES:
S. JOSHI
PROJECT MANAGER:
F. DIMALANTA
DRAWN BY:
INSPECTORS: ISSUE DATE: EHSI PROJECT #
11527-01
SCALE: SHEET
1011 SW Klickitat Way, Suite 104 Seattle, Washington 98134 Ph: 206.381.1128 Fax: 206.254.4279
LEGEND: DRAWING TITLE:
10/25/21-10/29/21 11/01/21-11/05/21 12/06/21
S. JOSHI
M. MACFARLANE
11/10/21
SL-6
NTSFOURTH FLOOR PLAN
11527-XX BULK ASBESTOS SAMPLE LOCATIONS
NORTH
1. DRAWING IS SCHEMATIC AND SAMPLE LOCATIONS ARE
APPROXIMATE.
2. REFER TO REPORT FOR MORE INFORMATION ABOUT THE SAMPLED
MATERIALS.
3. BACKGROUND DRAWING WAS PREPARED BASED ON SKETCHES
PREPARED IN THE FIELD.
ROOM IDENTIFIER
KEY PLAN
AREA E
NOT TO SCALE
AREA B
NOT TO SCALE
11527-156 11527-157 11527-158
11527-162
11527-163
11527-81
11527-79
11527-190
Tables
Table 1
Summary of Asbestos Bulk Sampling and Analytical Results
WRC Building 32
National Oceanic and Atmospheric Administration (NOAA)
7600 Sand Point Way NE
Seattle, WA 98115
EHSI Project Number: 11527
Sample Number Floor HSA Location Sample Description Result Quantity Units Material
Type
Friable/
Non-Friable
11527-01
11527-02 1 Room 101 Green carpet square on 12"x12" tan VCT w/ black mastic on 12"x12" black VCT w/black mastic on concrete
2-3% Chrysotile -black mastic
5-6% Chrysotile -black VAT
3% Chrysotile -black mastic
500 SF Misc. NF
11527-07
11527-08 1 Room 101 White JC on GWB with paint
3% Chrysotile - JC
ND - GWB w/ paint
Note: GWB as a system is <1% by composite anlsysis.
120 SF Misc. F
11527-05
11527-06 1 Room 101 White joint compound on plaster with brown backing
ND
(all layers) -- -- Misc. F
11527-21
11527-22 1 Room 101/112 Green board on plaster
ND
(all layers) -- -- Misc. F
11527-38
11527-39 1 Room 104 Tan/beige/black carpet w/ clear mastic on concrete ND -- -- Misc. NF
11527-24
11527-25 1 + 2 Room 104/210 2'x4' SACT w/ pinhole (PH) and wormtrack (WT) pattern w/ paint ND -- -- Misc. F
11527-11
11527-12 1 Room 108
White paint on 9"x9" black VCT w/ black mastic on concrete
6-7% Chrysotile -black VAT
2-3% Chrysotile -black mastic
150 SF Misc. NF
NORTH LEAN-TO
WRC Building 32
National Oceanic and Atmospheric Administration (NOAA)
7600 Sand Point Way NE
Seattle, WA 98115
EHSI Project Number: 11527
Sample Number Floor HSA Location Sample Description Result Quantity Units Material
Type
Friable/
Non-Friable
11527-09
11527-10
11527-10QA
1 Room 108 9"x9" Tan VCT w/ black mastic on 9"x9" black VCT w/ black mastic on concrete
11-12% Chrysotile -tan VAT
5-7 % Chrysotile -black VAT
1,200 SF Misc. NF
11527-58
11527-58QA
11527-63
1 Room 110 White fire stop (around copper pipe on refrigerators F2+F3) ND -- -- Misc. NF
11527-59
11527-60 1 Room 110 Silver seam caulking (around/in seams of refrigerators F2+F3) ND -- -- Misc. NF
11527-61
11527-62 1 Room 110 Clear/tan seam caulking (at base of refrigerator F2) ND -- -- Misc. NF
11527-64 1 Room 110 Clear silicone patch (on refrigerator F3) ND -- -- Misc. NF
11527-13
11527-14 1 Room 111
9"x9" Brown VCT w/ clear mastic on 9"x9" Gray VCT w/ clear mastic on concrete
ND
(all layers) -- -- Misc. NF
11527-15
11527-16 1 Room 111 4" Black cove base w/ black mastic on plaster wall
ND
(all layers) -- -- Misc. NF
11527-23 1 Room 112 Brown tac board w/ yellow mastic on plaster
ND
(all layers) -- -- Misc. NF
11527-40
11527-41 1 Room 112 White joint compound on plaster wall on GWB
ND
(all layers) -- -- Misc. F
11527-44
11527-45 1 Room 113 Beige/tan ceramic wall tile w/ grout on plaster walls
ND
(all layers) -- -- Misc. NF
11527-17
11527-18 1 Room 113 9"x9" Red ceramic tile w/ gray grout on concrete
ND
(all layers) -- -- Misc. NF
11527-172
11527-173 1 Room 200, 230 Yellow toilet caulking (around base of toilets) 4% Chrysotile 34 LF Misc. NF
11527-30
11527-33 2 Hallway 202 /220 Yellow carpet on black rubber pad w/ yellow mastic on wood
ND
(all layers) -- -- Misc. NF
WRC Building 32
National Oceanic and Atmospheric Administration (NOAA)
7600 Sand Point Way NE
Seattle, WA 98115
EHSI Project Number: 11527
Sample Number Floor HSA Location Sample Description Result Quantity Units Material
Type
Friable/
Non-Friable
11527-31
11527-32
11527-32QA
2 Hallway 210 / 207 4" Brown cove base w/ tan & brown mastic (on JC on wall) 2% Chrysotile1 Misc. NF
11527-34
11527-35 2 Room 224 4" Gray cove base w/ yellow mastic (on JC on wall) 2% Chrysotile1 Misc. NF
11527-70
11527-71 2 Room 212 Duct tape w/ white paint (around 12" OD return vent above SACT) ND -- -- Misc. NF
11527-36
11527-37 2 Hallway 212 / 220 Black vapor barrier w/ fiberglass insulation (above SACT)
ND
(all layers) -- -- Misc. NF
11527-48
11527-49 2 Room 213/208 Black window gasket on metal window frame ND -- -- Misc. NF
11527-28
11527-29 2 Room 219/208 Tan & beige carpet w/ black rubber back w/ yellow mastic on wood
ND
(all layers) -- -- Misc. NF
11527-26
11527-27 2 Room 223
Brown/tan rolldown carpet w/ brown mastic on black tile w/ black mastic on wood
7-8% Chrysotile -black VAT 710 SF Misc. NF
11527-46
11527-47 2 Room 224 1'8"x3'7" window gasket (on inside of wood frame) ND -- -- Misc. NF
11527-50
11527-51 2 Room 224 Black foam insulation barrier (on MFW 6'7"x3'18") ND -- -- Misc. NF
11527-52
11527-53 2 Room 224
6'7"x3'10" white window glazing putty (newer window) (between frame and outer wall frame) ND -- -- Misc. NF
11527-54
11527-55
11527-56
11527-56QA
11527-194
11527-195
Room C201 / 223
/ 224 / 225 / 227 /
228 / 300 / 400 /
Exit Stair 01
White skim coat on corner joints of wood windows/door frames 3-4% Chrysotile -skim coat 3,500 SF Surfacing F
11527-68
11527-69 2 Room 228 White fibrous material on tac board (on 4'x9')
ND
(all layers) -- -- Misc. NF
11527-57
11527-74 2 Room 228 / 301 Plaster w/ paint ND -- -- Misc. NF
WRC Building 32
National Oceanic and Atmospheric Administration (NOAA)
7600 Sand Point Way NE
Seattle, WA 98115
EHSI Project Number: 11527
Sample Number Floor HSA Location Sample Description Result Quantity Units Material
Type
Friable/
Non-Friable
11527-65
11527-66
11527-67
2 + 3 Exit Stair 01/02 1/3" white skim coat w/ tan paint on concrete stairwell ceilings
ND
(all layers) 600 SF Surfacing F
11527-72
11527-73 2 + 3 Exit Stair 01 Poured concrete w/ red paint (poured on floor of stairwell joints) ND -- -- Misc. NF
11527-75
11527-80 3 Room 301 Yellow/brown carpet w/ yellow mastic on concrete
ND
(all layers) -- -- Misc. NF
11527-76 3 Room 301 White paint (on decomissioned pipe) ND -- -- Misc. NF
11527-77 3 Room 301 Yellow window glazing putty (on inner panels of window) ND -- -- Misc. NF
11527-78 3 Room 301 White/brown window glazing patch (on exterior of window) ND -- -- Misc. NF
11527-79
11527-81 4 Room 401 Brown carpet w/ yellow mastic on concrete
ND
(all layers) -- -- Misc. NF
11527-82
11527-88 1 Exterior Brown window frame foam insulation w/ paint (on window) ND -- -- Misc. NF
11527-87 Ext Exterior White window edge frame caulking (between window frames/door frames & transite) 4% Chrysotile 1,500 LF Misc. NF
11527-86 Ext Exterior White/brown window frame glazing (around edges of window panes)
7'x12' wooden window frames 3% Chrysotile
3,000
8,000
SF
LF
EA
Misc. NF
11527-83 1 Exterior Clear silicone patch (on exterior window) ND -- -- Misc. NF
11527-84 1 Exterior White window edge frame caulking (between door & transite) ND -- -- Misc. NF
11527-85 1 Exterior Brown door frame caulking (between door & transite) ND -- -- Misc. NF
11527-192 1 Ext. Door N. Lean Brown door caulking ND -- -- Misc. NF
11527-19
11527-20 1 Outside Black slip pad w/ black mastic on concrete
ND
(all layers) -- -- Misc. NF
11527-90 1 Exterior NE Silver/gray door frame putty (ground NE door entrance to Bldg 8'x4') ND -- -- Misc. NF
11527-42
11527-43 1 Interior columns Silver paint (on columns & beams) ND -- -- Misc. F
11527-128
11527-129 1 Center Bldg. Black asphaltic seam sealant (in seams on center bldg. w/ copper wire) ND -- -- Misc. NF
CENTER BLDG. AREA BETWEEN GRID LINES B & D
WRC Building 32
National Oceanic and Atmospheric Administration (NOAA)
7600 Sand Point Way NE
Seattle, WA 98115
EHSI Project Number: 11527
Sample Number Floor HSA Location Sample Description Result Quantity Units Material
Type
Friable/
Non-Friable
11527-183
11527-188
11527-189
1 Center Bldg. S Wall White mesh paper w/ yellow fiberglass insulation on silver tape (on copper pipe)
ND
(all layers)
-- -- TSI F
11527-184 1 Center Bldg. S Wall Yellow padding w/ yellow mastic (on galvanized pipe)
ND
(all layers) -- -- Misc. NF
11527-185 1 Center Bldg. S Wall Clear silicone pipe dope (on 8" OD black pipe) ND -- -- Misc. NF
11527-186
11527-187 1 Center Bldg. S Wall Black asphaltic mastic (on inside of pipe galvanized cover) ND -- -- Misc. NF
11527-132 1 Room 133 Joint compound on GWB w/ paint (corner)
ND
(all layers) -- -- Misc. F
11527-133 1 Room 133 Skim coat on plaster w/ orange paint)
ND
(all layers) -- -- Surfacing F
11527-135 1 Room 133 / 134 Black countertop w/ brown mastic (on tan metal shelf) 14% Chrysotile 150 SF Misc. NF
11527-126
11527-127
11527-149
Room 133 / 145 /
Exit Stair 04
White window frame caulking (WFW between frame & wall
6'10"x4'11") ND -- -- Misc. NF
11527-136
11527-142 1 Room 134 White plumbers' putty (on 2" OD copper pipe) ND -- -- Misc. NF
11527-137 1 Room 134 Black sink gasket (on drain in sink 5" OD) ND -- -- Misc. NF
11527-138
11527-139
11527-140
1 Room 134 White mesh paper w/ yellow mastic on yellow fiberglass insulation on silver mesh paper (on copper pipe)
ND
(all layers)
-- -- TSI F
11527-141 1 Room 134 Gray sink drain gasket (5" OD) ND -- -- Misc. NF
11527-114 1 Room 135 Brown glue dots (on plaster ceiling above SACT) ND -- -- Misc. NF
11527-115 1 Room 135 4" Gray cove base w/ clear mastic on GWB
ND
(all layers) -- -- Misc. NF
11527-122
11527-123 1 Room 133/134 4" Cove base w/ tan mastic on GWB on plaster
ND
(all layers) -- -- Misc. NF
SOUTH LEAN-TO
WRC Building 32
National Oceanic and Atmospheric Administration (NOAA)
7600 Sand Point Way NE
Seattle, WA 98115
EHSI Project Number: 11527
Sample Number Floor HSA Location Sample Description Result Quantity Units Material
Type
Friable/
Non-Friable
11527-91
11527-92 1 Room 135/138 12"x12" Beige tile w/ black mastic on concrete
ND
(all layers) -- -- Misc. NF
11527-101 1 Room 135 Joint compound w/ GWB
ND
(all layers) -- -- Misc. F
11527-105
11527-106 1 Room 135/137 White interior door frame caulking (around frame & wall) ND -- -- Misc. NF
11527-99
11527-100 1 Room 137 White backsplash w/ yellow mastic on GWB
ND
(all layers) -- -- Misc. NF
11527-103
11527-104 1 Room 137 White formica countertop w/ clear mastic on wood
ND
(all layers) -- -- Misc. NF
11527-109
11527-109QA
11527-110
1 Room 137/138 Gray sink undercoating (beneath sink) ND -- -- Misc. NF
11527-111 1 Room 137 Black stainless steel large sink drain gasket (12'x4'3") mid room drain ND -- -- Misc. NF
11527-107 1 Room 137 Brown sink drain gasket (under sink) ND -- -- Misc. NF
11527-108
11527-113
11527-113QA
1 Room 137 Tan sink drain putty (around drain) 5" OD ND -- -- Misc. NF
11527-112 1 Room 138 Black sink drain gasket ND -- -- Misc. NF
11527-118 1 Room 139 Silver duct tape w/ brown paper backing
ND
(all layers) -- -- Misc. F
11527-116 1 Room 139 / 140 2'x4' suspended acoustic ceiling tile w/ paint w/ wormtrack pattern (20 ND -- -- Misc. F
11527-117 1 Room 139 / 140 Formica countertop w/ pink mastic
ND
(all layers) -- -- Misc. NF
11527-120
11527-121 1 Room 145A 2'x4' White SACT w/ flat pattern w/ silver backing ND -- -- Misc. F
11527-130
11527-131 1 Room 145A Silver duct tape on FG insulation (return vent)
ND
(all layers) -- -- Misc. NF
11527-143
11527-144 1 Room 146 White formica countertop w/ clear yellow mastic
ND
(all layers) -- -- Misc. NF
WRC Building 32
National Oceanic and Atmospheric Administration (NOAA)
7600 Sand Point Way NE
Seattle, WA 98115
EHSI Project Number: 11527
Sample Number Floor HSA Location Sample Description Result Quantity Units Material
Type
Friable/
Non-Friable
11527-145
11527-146 1 Room 146 Black sink drain gasket (right side 12# OD, left side 6" OD) ND -- -- Misc. NF
11527-124
11527-125
11527-134
11527-193
11527-196
11527-197
11527-147
11527-147QA
11527-148
1 Room 145 / 146 White/yellow skim coat GWB (on corner joints of walls/door frames) ND 1,650 SF Surfacing F
11527-152 1 Room 149 Yellow sink drain putty (4" OD) ND -- -- Misc. NF
11527-153
11527-154 1 Room 149 White plumbers' putty (3" OD around copper pipe) ND -- -- Misc. NF
11527-155 1 Room 149 Black sink drain gasket (6" OD) ND -- -- Misc. NF
11527-168 1 Room 149 3" EA hexagonal ceramic tile w/ gray grout on black grout on concrete
ND
(all layers) -- -- Misc. NF
11527-172
11527-173
Room 132, 149, 266, 288 Yellow toilet caulking (around base of toilets) 4% Chrysotile 34 LF Misc. NF
11527-169
11527-170 1 Room 149 4'8"x2'8" Mirror w/ black mastic on ceramic tile
ND
(all layers) -- -- Misc. NF
11527-171 1 Room 149 Gray shower grout (outside on shower ceramic wall) ND -- -- Misc. NF
11527-93 1 Exit Stair 03 Blue/green carpet squares w/ black mastic on concrete
ND
(all layers) -- -- Misc. NF
11527-102 2 Exit Stair 04 Black/purple rolled down carpet on tan tile w/ black mastic on concrete
ND
(all layers) -- -- Misc. NF
11527-176
11527-177 2 Room 266 Black sink drain gasket (6" OD) ND -- -- Misc. NF
11527-166
11527-167 2 Room 270
White window glazing (between glass window pane and metal window frame) 3% Chrysotile 100 LF Misc. NF
WRC Building 32
National Oceanic and Atmospheric Administration (NOAA)
7600 Sand Point Way NE
Seattle, WA 98115
EHSI Project Number: 11527
Sample Number Floor HSA Location Sample Description Result Quantity Units Material
Type
Friable/
Non-Friable
11527-94
11527-95 2 Room 273 / 274 Brown rolled down carpet on tan tile w/ black mastic on concrete
5% Chrysotile -black mastic 1,200 SF Misc. NF
11527-164
11527-165 2 Hallway 273 / 270 2"x1" yellow foam w/ yellow mastic on plaster
ND
(all layers) -- -- Misc. NF
11527-178
11527-179 2 Room 274/282 Joint compound on GWB w/ paint (corner)
ND
(all layers) -- -- Misc. F
11527-96 2 Room 276 Yellow/brown rolled down carpet on 12'x12' light beige tile w/ black mastic on concrete
4% Chrysotile -black mastic 150 SF Misc. NF
11527-97
11527-98 2 Room 277 / 279
Red rolled down carpet on beige 12'x12' VCT w/ black mastic on concrete
3% Chrysotile -black mastic 500 SF Misc. NF
11527-180 2 Room 277 White wall patch (patch on flaking paint) ND -- -- Misc. F
11527-175
11527-181
11527-182
3 Exit Stair 04 Yellow mud (on 5" OD black steam pipe on opening in stairwell) ND -- -- Surfacing F
11527-159 3 Room 302 Brown mastic (on east wall pipe run) ND -- -- Misc. NF
11527-160
11527-161
11527-174
4 Room 402 Maroon carpet squares w/ black mastic on tan tile w/ black mastic on concrete
5% Chrysotile -black mastic 300 SF Misc. NF
11527-156
11527-156QA
11527-190
11527-191
3 + 4 Room 403 / 303 Brown window frame caulking (with paint on MFW between window frame & wood frame interior) 5% Chrysotile 54 LF Misc. NF
11527-157 4 Room 403 Black window seam sealant (inner window) ND -- -- Misc. NF
11527-158 4 Room 403 White window seam caulking (inner window) ND -- -- Misc. NF
11527-162
11527-163 4 Exit Stair 04 Joint compound on GWB w/ paint (corner)
ND
(all layers) -- -- Misc. F
11527-150
11527-150QA
1 Exit Stair 04 Black steam tank gasket w/ paint (12" OD) (basement trench) 45% Chrysotile 1 EA Misc. F
11527-151 1 Exit Stair 04 Black steam tank gasket w/ paint (10" OD) (basement trench) ND -- -- Misc. F
11527-82
11527-88 1 Exterior Brown window frame foam insulation w/ paint (on window) ND -- -- Misc. NF
WRC Building 32
National Oceanic and Atmospheric Administration (NOAA)
7600 Sand Point Way NE
Seattle, WA 98115
EHSI Project…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .