589A4-21-100- SIGNED DRAWINGS R1_Part6.pdf

PDF 18 MB Posted

Attached to
Z2DA--Relocate Medical Ward for Patient Privacy PN:589A4-21-100
Solicitation number
36c25522R0024
Issued by

About this file

This solicitation is for the relocation of a medical ward to ensure patient privacy at a Veterans Affairs medical center. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15 and includes specifications and drawings for the project. Key details include a solicitation number of 36c25522R0024 for the project named Z2DA--Relocate Medical Ward for Patient Privacy PN:589A4-21-100. The solicitation is for construction services to move the existing medical ward and ensure compliance with privacy requirements. The response due date and anticipated award date are not provided.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ABDEFGHJKLMNPQRST

ACA A

WXYZ

8.0

ZONE 18

ZONE 19

ZONE 20

ZONE 23

D301A

D353

D353A

D332DD332A

D332B

D333 D333A D333B D334 D335 D336 D337

D338 D339

D340

D341

D339A

D338AD334A

D342D343

D344 D345

A335

A347

A316

A358

A317

A357

A319

A356

A321

A353A354

A321A A325

A352 A351

A350 A332 A348

C3A4A

A328 A331

A337 A338

A339

A340

A341

A342

A343

A344

A345

A346

A339AA330

A330A

A330B

A329A327A326A323A322

A318

A318A

A327AA323A

A320

B344

B318

A313

A314

A306A

A346A

D330

C3A6

C3A5

C3D5

C3A4

D330A

C3C9

D308C D301B

D301

C3C7

#3 #2 #1

B347

C3D1

C3B8

#4

#5

C3A2

B345

C3B5

C3A4

A312

A300

C3A3

D330A

C3C9

C3D1

C3B8

C3B5

C357

D320

D321

D322

D323

D319

D324

D325

D326

D327

D328

D329

D316

D347

D348

D349 D350

D351

D351A

C3D4

D316C

C3D4

C3D5

D352

C3D3

C361

C357A

C356A

C343

C338

C359

C3C5

C341

C360A

C3C4

C345

C360

C346

C356

C339

C358

C361A

C340

D316A

C358C

#6

C358A

C344

B328

C302

C308

C304

C303

G320 G320A

B309

C330

D346

B348

C3B4

B317

B343

B341

B322B323

B301

B303A

B325B305

B305AB307AB309A

B306 B304 B302

B#?

B336 B310 B308

B315

B315B B330

B312A

B311

B312

B313

B314

B335

B322

B316

D331

B316B

B351

G347

G300

G305

G317 G321

G357

G356

G355 #13 #12

C320 C319

G322G323

B331

C318

C3B2

C3C1

C325

D302

#7

G346

G344

G342

G338

G336

G334

G332 G330

G329

G327 G325 G324

G313

G311

G309

G307 G303

G304

G315

G302

G370

G371

G372

G373 1844

G374

G363

G359

G364

G301

G301A

C307

C306

B332B333

C313A

C314A

B311A

B329

B337 B310A

B327

B307

B308A B306A

B324

B303

B301A

B304A B302A

B315A

B316A

B317A B318A

B338

B321

B300 B320

C3B9

B326

C3B1

B340

B339 B342

C364

C350

C363AC364A

C365A

C363 C362

C350A

C349A

C354

C333

C347

C353

C355

C352

C332

C336

C365

C351

C349

C335

C321 C322

C3C3

C334

C327

C328

C328A

C337

C348

C348A

C324

C329

C362A

C337A

C323

C368 C369

C353B

C351A

C316

G344A

G342A

G340

G340A

G338A

G336A

G334A

G332A G330A G327A G325A

G313A

G311A

G309A

G307A

G1

G361 G362

G361A

C305

G375

THIRD FLOOR KEY PLAN

A

B

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

FD110

DEMOLITION PLAN - 3RD FLOOR FIRE

SUPPRESSION - OVERALL

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

DGKDGK

1/16" = 1'-0"

DEMOLITION PLAN - 3RD FLOOR FIRE SUPPRESSION - OVERALL

N

KEYNOTES

1 BOLD DASHED LINE DEFINES PROJECT RENOVATION AREA. SPRINKLERS AND CORRESPONDING

SPRINKLER ZONES SHOWN ARE TAKEN FROM CONTRACTOR’S SHOP DRAWING SUBMITTAL WITH

FIELD SPRINKLER LOCATION REVISIONS BASED ON SITE OBSERVATION. FLOOR PLANS IN SOME

AREAS HAVE BEEN MODIFIED FROM PLANS THAT SHOP DRAWINGS ARE BASED FROM AND

SPRINKLER ZONES OUTSIDE THE PROJECT AREA AND NEAR THE PROJECT BORDER ARE LIKELY

MODIFIED; HOWEVER, NO PLANS WERE AVAILABLE FOR ANY MODIFICATIONS. CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS PRIOR TO CREATION OF SHOP DRAWING SUBMITTAL.

2 RISER WITH SPRINKLER ZONE CONTROL FOR ZONE 19. REMOTE DESIGN PLACARD AT ZONE

CONTROL VALVE NOT FILLED IN.

3 RISER WITH SPRINKLER ZONE CONTROL FOR ZONE 20.

4 RISER WITH SPRINKLER ZONE CONTROL FOR ZONE 23. REMOTE DESIGN AREA FOR THIS ZONE IS STAFF BEDROOMS. NUMBER OF SPRINKLERS FLOWING IS 18. REMOTE AREA DESIGNED FOR LIGHT

HAZARD WITH A DESIGN DENSITY OF 0.10 GPM PER SQUARE FOOT OVER 1670 SQUARE FEET.

SYSTEM DEMAND IS 601.6 GPM AT 110.08 PSI. SUPPLY INFORMATION TAKEN FOR CURRENT REMOTE

AREA DESIGN PLACARD. REVISE PLACARD WITH NEW REMOTE DESIGN REQUIREMENTS UPON

COMPLETION OF PROJECT.

5 EXISTING STANDPIPE RISER ABANDONED IN PLACE.

6 RISER WITH SPRINKLER ZONE CONTROL FOR ZONE 18. REMOTE DESIGN AREA FOR THIS ZONE IS STAFF BEDROOMS. NUMBER OF SPRINKLERS FLOWING IS 19. REMOTE AREA DESIGNED FOR LIGHT

HAZARD WITH A DESIGN DENSITY OF 0.10 GPM PER SQUARE FOOT OVER 1500 SQUARE FEET.

SYSTEM DEMAND IS 571.7 GPM AT 71.02 PSI. SUPPLY INFORMATION TAKEN FOR CURRENT REMOTE

AREA DESIGN PLACARD. REVISE PLACARD WITH NEW REMOTE DESIGN REQUIREMENTS UPON

COMPLETION OF PROJECT.

F-300

1___

F-300

3___

ABDEFGHJJb

8.0

F-300

1___

F-300

3___

D329

D301A

D353

D353A

D332DD332A

D332B

D333

D333A D333B

D334 D335 D336 D337 D338 D339

D340

D341

D339A

D338A D334A

D335A D338B

D342

D343

D344 D345

D346 D347

A335

A347

A316

A358

A317

A357

A319

A356

A321

A353A354

A321A

A325

A352

A351

A350

A332 A348

C3A4A

A328

A331

A337

A338

A339

A340

A341

A342

A343

A344

A345

A346

A339A

A330

A330A

A330B

A329A327A326A323A322

A318

A318A

A329AA327AA326AA323A

A320

B344

B318

A313

A314

A306A

A346A

D330

D331

C3D4

D331BD331C

C3A6

C3A5

C3D5

C3A4

D330A

D308C D301B

D301

C3C7

#3 #2 #1

C3D1

#4

#5

C3A2

C338 C339

C3A4

A312

A300

C3A3

PATIO

D347

THIRD FLOOR KEY PLAN - AREA A

A

N

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

FD111

DEMOLITION PLAN - 3RD FLOOR FIRE

SUPPRESSION - AREA A

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

DGKDGK

N

KEYNOTES

1 REMOVE ALL SPRINKLERS AND CORRESPONDING SPRINKLER PIPING LOCATED WITHIN BOLD

DASHED LINE WHICH DEFINES THE PROJECT RENOVATION SPACE. RENOVATION SHALL INCLUDE

EXTENSIVE BACKGROUND CHANGES THAT WILL REQUIRE HIGHER SPRINKLER DEMAND THAN THE

CURRENT INSTALLATION. RENOVATION WILL ALSO INCLUDE SIGNIFICANT HVAC AND PLUMBING

UPGRADES THAT WILL REQUIRE EXISTING MAINS TO BE RELOCATED. SMOKE ZONES SHALL BE

MODIFIED WITH THIS PROJECT AS WELL. SEE SHEET FD110 FOR THE CURRENT SPRINKLER ZONE

MAP AND SHEET FX110 FOR THE NEW ZONE MAP. ALL CONSTRUCTION TO BE DONE IN PHASES.

KEEP EXISTING SYSTEM IN SERVICE AS LONG AS POSSIBLE. SYSTEM SHALL BE MAINTAINED

THROUGHOUT CONSTRUCTION. PROVIDE UPRIGHT STYLE PROTECTION DURING CONSTRUCTION

REPLACE WITH FINAL SPRINKLERS MEETING PROJECT REQUIREMENTS WHEN CEILINGS HAVE BEEN

PROVIDED.

1/8" = 1'-0"

DEMOLITION PLAN - 3RD FLOOR FIRE SUPPRESSION - AREA A

F-300

4___

D329

D348

C3D4

C3D4

C3D1 C338

C339

C357

D320

D321

D322

D323

D318

D319

D324

D325

D326

D327

D328

D316

D349

D350

D351

D351A

D316C

D352

C3D3

C361

C357A

C356A

C343

C359

C341

C360A

C345

C360

C346

C356

C358

C361A

C340

D316A

C358C

#6

C358A

C344

D347

C3D5

ABDEFGHJJb

F-300

4___

THIRD FLOOR KEY PLAN - AREA B

BN

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

FD112

DEMOLITION PLAN - 3RD FLOOR FIRE

SUPPRESSION - AREA B

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

DGKDGK

N

KEYNOTES

1 REMOVE ALL SPRINKLERS AND CORRESPONDING SPRINKLER PIPING LOCATED WITHIN BOLD

DASHED LINE WHICH DEFINES THE PROJECT RENOVATION SPACE. RENOVATION SHALL INCLUDE

EXTENSIVE BACKGROUND CHANGES THAT WILL REQUIRE HIGHER SPRINKLER DEMAND THAN THE

CURRENT INSTALLATION. RENOVATION WILL ALSO INCLUDE SIGNIFICANT HVAC AND PLUMBING

UPGRADES THAT WILL REQUIRE EXISTING MAINS TO BE RELOCATED. SMOKE ZONES SHALL BE

MODIFIED WITH THIS PROJECT AS WELL. SEE SHEET FD110 FOR THE CURRENT SPRINKLER ZONE

MAP AND SHEET FX110 FOR THE NEW ZONE MAP. ALL CONSTRUCTION TO BE DONE IN PHASES.

KEEP EXISTING SYSTEM IN SERVICE AS LONG AS POSSIBLE. SYSTEM SHALL BE MAINTAINED

THROUGHOUT CONSTRUCTION. PROVIDE UPRIGHT STYLE PROTECTION DURING CONSTRUCTION

REPLACE WITH FINAL SPRINKLERS MEETING PROJECT REQUIREMENTS WHEN CEILINGS HAVE BEEN

PROVIDED.

1/8" = 1'-0"

DEMOLITION PLAN - 3RD FLOOR FIRE SUPPRESSION - AREA B

F

FF

SD

SD

SD

SD

SD

SD

SDSDSDSD

SDSDSD

SD

SD

SD

SD

SD

F

SD

SD

SD

SD

SD

SD

SD

D301A

D353 D353A

D332D

D332A

D332B

D333 D333A

D333B

D334 D335 D336 D337 D338 D339

D340

D341

D339A

D338A D334A

D335A D338B

D342

D343

D344

D345

A335

A347

A316

A358

A317

A357

A319

A356

A321

A353A354

A321A A325

A352

A351 A350

A332 A348

A328 A331

A337

A338

A339

A340

A341

A342 A343

A344

A345

A346

A339A

A330

A330A

A329A327A326A323A322

A318

A318A

A326A A323A

A320

B344

B318

A313

A314

A306A

A346A

D330

C3A6

C3A5

C3D5

C3A4

D308C D301B

D301

C3C7

#3 #2 #1

B347

#4

#5

C3A2

B345

C3A4

A312

A300

C3A3

C3D1

D329

D347D348 C3D4

CORR.

PATIO

C338

C339

ABDEFGGaHJJb

8.2

BaBbH.5

ACA A

Ja

8.3

8.0

Aa

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

THIRD FLOOR KEY PLAN - AREA A

A

N

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

FD211

DEMOLITION PLAN - 3RD FLOOR FIRE

ALARM - AREA A

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

SCTEMN

N

KEYNOTES

1 EXISTING FIRE ALARM TRANSPONDER PANEL (FATC) AND NAC EXTENDER PANEL LOCATION. FATC

AND NAC PANELS SHALL REMAIN.

2 EXISTING FIRE ALARM SMOKE DETECTOR SHALL REMAIN.

3 EXISTING TAMPER AND FLOW SWITCHES SHALL REMAIN. COORDINATE RECONNECTING SWITCHES

AS REQUIRED FOR CONSTRUCTION WORK.

4 WHERE EXISTING CEILING WORK IS BEING COMPLETED ON SECOND FLOOR FOR ABOVE CEILING PLUMBING WORK, COORDINATE REMOVAL AND REINSTALLING/RECONNECTING ANY EXISTING FIRE

ALARM DEVICES THAT ARE CEILING MOUNTED AND ARE IMPACTED BY CEILING WORK.

5 EXISTING MAG HOLD OPENS PANEL LOCATED IN ROOM WITH TRANSFORMER AND POWER SUPPLY SERVING THEM. ALL EXISTING NON ADDRESSABLE MAG HOLD OPENS, SERVED BY PANEL, ARE TO

BE REMOVED IN ENTIRETY ON FLOOR. REMOVE PANEL, TRANSFORMER, AND POWER SUPPLY

AFTER REMOVAL OF ALL EXISTING HOLD OPENS. COORDINATION SHALL BE DONE TO COORDINATE

EXISTING HOLD OPENS BEING REMOVED ON FLOOR BY SEPARATE PROJECT TO CORRECT FIRE &

LIFE SAFETY DEFICIENCIES.

1/8" = 1'-0"

DEMOLITION PLAN - 3RD FLOOR FIRE ALARM - AREA A

SEE SHEET FD112 FOR EXISTING

SMOKE ZONE BOUNDARIES AND

IDENTIFICATION.

SD

F

SD

SD

SD

SD

SD

SD

SD

FE

F E

C

FEC

FEC

FE

F E

FE

F E

F E

FE

FE

F E

FEC

F E

C

FEC

DNUP

FD FD

F D

F D

FD

FD

FD FD FD FD

FD

FD

FD

FD

FD

FD

FD

FD

C3D1

C3D1

C357

D320

D321

D322

D323

D318

D319

D324

D325

D326

D327

D328

D316

D347D348

D349 D350

D351

D351A

C3D4

D316C

C3D4

D352

C3D3

C361

C357A

C356A

C343

C359

C341

C360A

C345

C360

C346

C356

C339

C358

C361A

C340

D316A

C358C

#6

C358A

C344

ABDEFGHJJb

(TYP)

THIRD FLOOR KEY PLAN - AREA B

BN

S C

-4

S C

-3

SC

3-2

SC

3-1

SC3-3

SC3-5

SC3-2

SC3-5

S C

-3

S C

-2

S C

3- 1S C

3-

SC

3-4

SC

3-3

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

FD212

DEMOLITION PLAN - 3RD FLOOR FIRE

ALARM - AREA B

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

SCTEMN

N

KEYNOTES

1 EXISTING TAMPER AND FLOW SWITCHES SHALL BE REMOVED. COORDINATE REMOVING

CONNECTION WITH FIRE SPRINKLER CONTRACTOR.

2 WHERE EXISTING CEILING WORK IS BEING COMPLETED ON SECOND FLOOR FOR ABOVE CEILING PLUMBING WORK, COORDINATE REMOVAL AND REINSTALLING/RECONNECTING ANY EXISTING FIRE

ALARM DEVICES THAT ARE CEILING MOUNTED AND ARE IMPACTED BY CEILING WORK.

1/8" = 1'-0"

DEMOLITION PLAN - 3RD FLOOR FIRE ALARM - AREA B

1" = 40'-0"

FLOOR PLAN - EXISTING 3RD FLOOR SMOKE ZONES - OVERALL

E

C

F E

FE

FE

A235

A222

A222A

A223

A225 A227

A228

A229

A230

A232

A251A

A246

A249

A249A

A250

A244

A244A

A241

A251

A252A

A252

D229

D231A D229A

D230

D228

D227D227A

D231

A233

A236

A234

A246A

A253A254

A255A256A257

A258

D222 D223

D224 D226D221

C2A6BC2A6A

C2A4BC2A4A

A262

A259A260

A220

A221

A214

A204

A205

A204A

D220

D219B

D219F

D219HD219G

D219A

D219

D203

A216A215

A213

A219

A211

A213

A212

C2A5

C2A4

A200

D201A D201

A200A

C2A3

C2A6

C2E8

D225

#3 #1

D221A

#2

D232

D205A D204 D219C D219D

D219E D206

D232 D231

ABDEFGHJJb

3.2

8.0

F-300

2___

SECOND FLOOR KEY PLAN - AREA A

A

N

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

FX101

FLOOR PLAN - 2ND FLOOR FIRE

SUPPRESSION - AREA A

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

MKMDGK

N

KEYNOTES

1 REPLACE ALL SPRINKLERS REQUIRED TO BE REMOVED TO ACCOMMODATE PLUMBING UPGRADES

TO THE THIRD FLOOR WITH NEW SPRINKLERS ON FLEXIBLE DROPS. NEW SPRINKLERS SHALL

MATCH REMOVED SPRINKLERS IN STYLE, TEMPERATURE RATING AND FINISH. INSTALL NEW

SPRINKLERS AT THE ORIGINAL SPRINKLER LOCATION. ITEMS KNOWN TO BE IN CONFLICT ON THE DEMOLITION SHEET ARE SHOWN HERE BOLD. THIS IS THE MINIMUM REQUIRED TO BE REPLACED.

COORDINATE CLOSELY WITH MECHANICAL CONTRACTOR FOR ANY OTHER SPRINKLERS THAT MAY

NEED REPLACEMENT TO ACCOMMODATE THIRD FLOOR UPGRADES. ALL NEW CEILINGS SHALL BE

INSTALLED ON FM APPROVED FLEXIBLE DROPS.

1/8" = 1'-0"

FLOOR PLAN - 2ND FLOOR FIRE SUPPRESSION - AREA A

CONTRACTOR SHALL PATCH AND

REAPPLY ANY SPRAYED-ON

FIREPROOFING THAT IS REMOVED TO

FACILITATE THE INSTALLATION OF

FIRE SPRINKLER HANGERS.

C

F E

C

F E

FE

FE

C2D6

D205A D204 D219C D219D

D219E D206

D233

D234

D236

D240

D238

D241

D239

D237

D235AD235

D238A

D205

D200A

D205B

D205C

C235B

C235

C236

C237

C238

C239

C240

C241

C242 C243

C237A

D218

D218A

D218BD218C

D216D

D216

D210

D214 D215

D208

D209

D207

D207BD207C

C2D1

C2D3

D217

D218

D213F

D213E D213G

D213D

D213B

C2D4

D213A

D213C

D213L D213H

DD213J

D213K

#6

D209A

D207A

D232 D231

ABDEFGHJJb

8.2

9.1

10.4

10.2

9.8

8.9

8.3

8.0

F-300

6___

F-300

5___

SECOND FLOOR KEY PLAN - AREA B

BN

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

FX102

FLOOR PLAN - 2ND FLOOR FIRE

SUPPRESSION - AREA B

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

AuthorChecker

N

KEYNOTES

1 REPLACE ALL SPRINKLERS REQUIRED TO BE REMOVED TO ACCOMMODATE PLUMBING UPGRADES

TO THE THIRD FLOOR WITH NEW SPRINKLERS ON FLEXIBLE DROPS. NEW SPRINKLERS SHALL

MATCH REMOVED SPRINKLERS IN STYLE, TEMPERATURE RATING AND FINISH. INSTALL NEW

SPRINKLERS AT THE ORIGINAL SPRINKLER LOCATION. ITEMS KNOWN TO BE IN CONFLICT ON THE DEMOLITION SHEET ARE SHOWN HERE BOLD. THIS IS THE MINIMUM REQUIRED TO BE REPLACED.

COORDINATE CLOSELY WITH MECHANICAL CONTRACTOR FOR ANY OTHER SPRINKLERS THAT MAY

NEED REPLACEMENT TO ACCOMMODATE THIRD FLOOR UPGRADES. ALL NEW CEILINGS SHALL BE

INSTALLED ON FM APPROVED FLEXIBLE DROPS.

1/8" = 1'-0"

FLOOR PLAN - 2ND FLOOR FIRE SUPPRESSION - AREA B

CONTRACTOR SHALL PATCH AND

REAPPLY ANY SPRAYED-ON

FIREPROOFING THAT IS REMOVED TO

FE

E

FE

F E

F E

F E

FEC

F E

C

FEC

FEC

F E

C

F E

C

FEC

FEC

F E

C F

E C

FD FD

F D

F D

FD

FD

FD FD FD FD

FD

FD

FD

FD

FD

FD

FD

FD

ZONE 18

ZONE 19

ZONE 20

ZONE 23

ZONE 18

ZONE 19

ZONE 20

ZONE 23

THIRD FLOOR KEY PLAN

A

B

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

FX110

FLOOR PLAN - 3RD FLOOR FIRE

SUPPRESSION - OVERALL

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

DGKDGK

1/16" = 1'-0"

FLOOR PLAN - 3RD FLOOR FIRE SUPPRESSION - OVERALL

N

KEYNOTES

1 BOLD DASHED LINE REPRESENTS PROJECT RENOVATION AREA. REVISE EXISTING SPRINKLER

ZONES TO MEET NEW ZONE REQUIREMENTS.

2 RISER WITH SPRINKLER ZONE CONTROL FOR ZONE 20.

3 RISER WITH SPRINKLER ZONE CONTROL FOR ZONE 23. REMOTE DESIGN AREA FOR THIS ZONE IS STAFF BEDROOMS. NUMBER OF SPRINKLERS FLOWING IS 18. REMOTE AREA DESIGNED FOR LIGHT

HAZARD WITH A DESIGN DENSITY OF 0.10 GPM PER SQUARE FOOT OVER 1670 SQUARE FEET.

SYSTEM DEMAND IS 601.6 GPM AT 110.08 PSI. SUPPLY INFORMATION TAKEN FOR CURRENT REMOTE

AREA DESIGN PLACARD. REVISE PLACARD WITH NEW REMOTE DESIGN REQUIREMENTS UPON

COMPLETION OF PROJECT.

4 RISER WITH SPRINKLER ZONE CONTROL FOR ZONE 18. REMOTE DESIGN AREA FOR THIS ZONE IS STAFF BEDROOMS. NUMBER OF SPRINKLERS FLOWING IS 19. REMOTE AREA DESIGNED FOR LIGHT

HAZARD WITH A DESIGN DENSITY OF 0.10 GPM PER SQUARE FOOT OVER 1500 SQUARE FEET.

SYSTEM DEMAND IS 571.7 GPM AT 71.02 PSI. SUPPLY INFORMATION TAKEN FOR CURRENT REMOTE

AREA DESIGN PLACARD. REVISE PLACARD WITH NEW REMOTE DESIGN REQUIREMENTS UPON

COMPLETION OF PROJECT.

5 RISER WITH SPRINKLER ZONE CONTROL FOR ZONE 19. REMOTE DESIGN PLACARD AT ZONE

CONTROL VALVE NOT FILLED IN.

CONTRACTOR SHALL PATCH AND

REAPPLY ANY SPRAYED-ON

FIREPROOFING THAT IS REMOVED TO

J

J

J J J

SD

SD

SD

SD

SD

SD

SD

SD

F E

C

FEC

FEC

F E

C F

E C

DN UP

ABDEFGHJJb

8.0

CORR.

C3A4

MEDS

A335

GEN. STOR.

A326

CLEAN

A336

SOILED

A337

CLEAN LINEN

A336A

NURSE

D314

MEDS

D315

SOILED

D316

ISO/BAR #1

A301

ISO/BAR #2

A302

ISO/BAR #3

A303

MEDS

A319

NOUR.

A324

NURSE MGR/

ASST MGR.

A325

PAT. RM #21

D321

BARIATRIC

#20

D320

ISO/BAR #19

D319

BARIATRIC

#18

A318

PAT. RM #17

A317

PAT. RM #16

A316

BARIATRIC

#15

A315

PAT. RM #14

A314

BARIATRIC

#13

A313

DIALYSIS

D342

TLT./SHWR

A313A

TLT./SHWR

A314A

TLT./SHWR

A315A

TLT./SHWR

A316A

TLT./SHWR

A317A

TLT./SHWR

A318A

TLT./SHWR

D319A

TLT./SHWR

D320A

TLT./SHWR

D321A

NURSE

A328

TLT./SHWR

A302A

TLT./SHWR

A301A

ANTE

D319B

ANTE

A301B

ANTE

A302B

ANTE

A303B

CORR.

C3A6

NURSE

WK/COPY

A329

TLT.

A338

SOILED

D342A

ELEC

D338

STAFF

LOUNGE

D343

LOCKER

D343A

TLT./SHWR

A303A

PAT. RM #6

D306

TLT./SHWR

D306A

PAT. RM #8

D308

PAT. RM #10

D310

PAT. RM #12

D312

TLT./SHWR

D312A

TLT./SHWR

D310A

TLT./SHWR

D308A

EQUIP

D311

TLT./SHWR

D304A

PAT. RM #4

D304

STRETCHER

D303

EQUIP.

D305

STRETCHER

D309

MED. GAS

D307

NOUR.

D313

MSA

D302

NURSE

A332

PAT. RM #11

A311

PAT. RM #9

A309

PAT. RM #7

A307

TLT./SHWR

A311A

TLT./SHWR

A309ATLT./SHWR

A307A

ELEC./SYSTEMS

A330

CLEAN

A321

PAT. RM #5

A305

TLT./SHWR

A305A

CLEAN LINEN

A322

SOILED

A320

NURSE

WK/COPY

A333

NOUR.

A334

CORR.

C3A2

CORR.

C3A3

CORR.

C3D4

STAIR #4

A346

STAIR #2

D340

F-300

6___

CONSULT

RM.

D344

STORAGE

D345

CORR.

C3D5

6 6

PAT. RM #22

D322

TLT./SHWR

D322A

F-300

2___

HSKPG

A331

(TYP)18

CORR.

C3A1

FX111

2___

FX111

3___

CORR.

C3A5

SM-19

SM-19

(TYP)

STORAGE

A327

THIRD FLOOR KEY PLAN - AREA A

A

N

Bb

ZONE 19

SPRINKLER MAIN

BOTTOM OF DECK

CORRIDOR CEILING

Bb

ZONE 19

SPRINKLER MAIN

BOTTOM OF DECK

CORRIDOR CEILING

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

FX111

FLOOR PLAN - 3RD FLOOR FIRE

SUPPRESSION - AREA A

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

MKMDGK

N

KEYNOTES

1 PROVIDE NEW SPRINKLER LAYOUT TO MEET THE NEW FLOOR PLAN REQUIREMENTS. SPRINKLERS SHALL BE DESIGNED FOR A LIGHT HAZARD OCCUPANCY WITH A DESIGN DENSITY OF 0.10 GPM PER SQUARE FOOT OVER 1500 SQUARE FEET UNLESS OTHERWISE NOTED. SEE SHEET FX400 FOR NEW

SPRINKLER ZONE REQUIREMENTS.

2 OVERHEAD STRUCTURALLY MOUNTED PATIENT LIFT RAIL AND TRACK SYSTEM. COORDINATE

SPRINKLER SYSTEM SPRINKLERS AND SPRINKLER PIPING WITH LIFT. DO NOT INSTALL PIPING IN A FASHION THAT WILL PREVENT PROPER OPERATION OF TRACK AND DO NOT INSTALL SPRINKLERS IN

A FASHION THAT WILL BE DAMAGED WITH EXPECTED OPERATION OF TRACK. DO NOT INSTALL

SPRINKLERS IN SPACE BETWEEN RAILS WHERE CROSS BAR OF LIFT TRAVELS. PROVIDE

ADDITIONAL SPRINKLERS IF NEEDED TO MEET THIS REQUIREMENT.

3 CEILING 5-3/4" TO 7-3/4” (VARIES BY PATIENT ROOM) HIGHER THAN ADJACENT CEILING GRID TO

ACCOMMODATE EXISTING WINDOW. PROTECT SPACE WITH SIDEWALL STYLE SPRINKLERS WHEN

SPACE PERMITS. OTHERWISE, PROTECT WITH RECESSED PENDENT. AT A MINIMUM, SPRINKLERS

IN THIS SPACE SHALL BE INTERMEDIATE TEMPERATURE RATED. PROVIDE HIGH TEMPERATURE

RATED SPRINKLERS IF INSTALLED WITHIN 7’OF RADIANT HEATER.

4 CEILING BULKHEAD EXTENDS 10” BELOW ADJACENT CEILING GRID.

5 ALL KEYNOTES WITHIN BOLD DASHED LINE ARE TYPICAL FOR ALL PATIENT ROOM AREAS.

6 ROOM SHALL BE DESIGNED FOR AN ORDINARY HAZARD GROUP 2 OCCUPANCY WITH A DESIGN

DENSITY OF 0.20 GPM PER SQUARE FOOT OVER 1500 SQUARE FEET.

7 ELECTRICAL ROOM SHALL BE DESIGNED FOR AN ORDINARY HAZARD GROUP 1 OCCUPANCY WITH A

DESIGN DENSITY OF 0.15 GPM PER SQUARE FOOT OVER 1500 SQUARE FEET. DO NOT ROUTE

THROUGH THIS ROOM TO SERVE OTHER AREAS OF THE BUILDING. SPRINKLERS SERVING THIS

SPACE SHALL BE INTERMEDIATE TEMPERATURE (200 – 225 DEG. F) RATED. COORDINATE WITH

ELECTRICAL CONTRACTOR TO ENSURE PIPES DO NOT ROUTE OVER THE TOP OF ELECTRICAL

PANELS OR EQUIPMENT.

8 NOOK OFF OF CORRIDOR USED FOR STORAGE ON MOBILE CARTS. PROVIDE SPRINKLER WITHIN

NOOK AND COORDINATE WITH ADJACENT CORRIDOR SPRINKLERS TO ENSURE SPACING PREVENT

COLD SOLDERING.

9 MED GAS STORAGE WILL HAVE GAS TANKS CHAINED IN THE UPRIGHT POSITION. ROOM SHALL BE DESIGNED FOR AN ORDINARY HAZARD GROUP 2 OCCUPANCY WITH A DESIGN DENSITY OF 0.20 GPM

PER SQUARE FOOT OVER 1500 SQUARE FEET.

10 CEILING FEATURE IS 3” HIGHER THAT SURROUNDING CEILING GRID. SPACE ABOVE THIS AREA WILL

BE TIGHT. PROVIDE LAYOUT THAT DOES NOT ROUTE PIPING OVER THIS SPACE EXCEPT THAT

REQUIRED FOR SPRINKLERS SERVING THIS SPACE. COORDINATE PIPE ROUTING WITH ALL OTHER

DISCIPLINES, ESPECIALLY WITH NEW HVAC DUCTWORK.

11 STORAGE ROOM SHALL BE DESIGNED FOR AN ORDINARY HAZARD GROUP 2 OCCUPANCY WITH A DESIGN DENSITY OF 0.20 GPM PER SQUARE FOOT OVER 1500 SQUARE FEET. COORDINATE WITH PLANNED STORAGE SHELVING. DO NOT INSTALL SPRINKLERS DIRECTLY OVER THE FOOTPRINT OF

SHELVING. SPRINKLERS SHALL HAVE PROTECTIVE WIRE GUARDS.

12 CEILING 5-3/4" HIGHER THAN ADJACENT CEILING GRID TO ACCOMMODATE EXISTING WINDOW.

13 RECONNECT EXISTING TO REMAIN SPRINKLER BRANCH PIPING. FIELD VERIFY SIZE.

14 CAP EXISTING 1” SPRINKLER BRANCH MAIN.

15 CAP EXISTING MAIN. FIELD VERIFY EXISTING PIPE SIZE.

16 CONNECT EXISTING 1” SPRINKLER BRANCH PIPE TO NEW FIRE MAIN PROVIDED TO SERVE ZONE 18.

FIELD VERIFY EXISTING PIPE SIZE AND LOCATION PRIOR TO CREATION OF SHOP DRAWING

SUBMITTAL.

17 FACE OF UPPER-LEVEL CABINETS ARE FLUSH WITH WALL. SEE ARCHITECTURAL PLANS FOR

FURTHER DETAILS.

18 CEILING MOUNTED RADIANT HEATER.

19 CEILING 5-3/4" HIGHER THAN ADJACENT CEILING GRID TO ACCOMMODATE EXISTING WINDOW.

SURROUNDING BULKHEAD WALLS EXTEND 1’-9” BELOW ADJACENT ACT CEILING.

20 PATIENT PRIVACY CURTAIN TO BE PROVIDED BY THE VA. IT IS EXPECTED THAT THE TOP FOOT OF THE CURTAIN WILL HAVE OPEN MESH; HOWEVER, CONTRACTOR SHALL VERIFY PRIOR TO CREATION OF SHOP DRAWING SUBMITTAL. PROVIDE LAYOUT THAT WORKS WHETHER THE CURTAIN IS IN THE

OPEN POSITION OR IN THE CLOSED POSITION.

21 STORAGE SHALL INCLUDE MOVABLE ROLLING SHELVING. LIMIT SPRINKLER DESIGN TO 100 SQUARE

FOOT PER SPRINKLER.

1/8" = 1'-0"

FLOOR PLAN - 3RD FLOOR FIRE SUPPRESSION - AREA A

1/2" = 1'-0"

ZONE 19 MAIN - CORR C3D5

1/2" = 1'-0"

ZONE 19 MAIN - CORR C3A5

CONTRACTOR SHALL PATCH AND

REAPPLY ANY SPRAYED-ON

FIREPROOFING THAT IS REMOVED TO

SD

SD

F E

F E

C

FEC

FEC

F E

C

ABDEFGHJJb

H.5Ja

CLEAN

D317

CLEAN LINEN

D317A

PAT. RM #24

D324

PAT. RM #23

D323

PT TLT.

D323A

TLT./SHWR

D324A

CORR.

C3D5

HSKPG

D326

TLT.

D318

CODER/REVIEW

D334

SWAMP #2

D332

SWAMP #3

D330

COPY

D336

TLT.

D341

CHG ROOM

D343B

SHARED

OFFICE

D335

WAD

D339

OFFICE

D333

HOSPITALIST

D328

SWAMP #1

D331

SWAMP #4

D329

CORR.

C3D3

SOCIAL

D337

STAIR #5

D325

STAIR #6

D327

CORR.

C3C4

EX STOR. RM

C359

CORR.

C3D4

ELEC

D338

F-300

5___

CORR.

C3D3

LOCKER

D343A

SM-19

THIRD FLOOR KEY PLAN - AREA B

BN

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

FX112

FLOOR PLAN - 3RD FLOOR FIRE

SUPPRESSION - AREA B

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

DGKDGK

N

KEYNOTES

1 PROVIDE NEW SPRINKLER LAYOUT TO MEET THE NEW FLOOR PLAN REQUIREMENTS. SPRINKLERS SHALL BE DESIGNED FOR A LIGHT HAZARD OCCUPANCY WITH A DESIGN DENSITY OF 0.10 GPM PER SQUARE FOOT OVER 1500 SQUARE FEET UNLESS OTHERWISE NOTED. SEE SHEET FX400 FOR NEW

SPRINKLER ZONE REQUIREMENTS.

2 ROOM SHALL BE DESIGNED FOR AN ORDINARY HAZARD GROUP 2 OCCUPANCY WITH A DESIGN

DENSITY OF 0.20 GPM PER SQUARE FOOT OVER 1500 SQUARE FEET.

3 CEILING 5-3/4" HIGHER THAN ADJACENT CEILING GRID TO ACCOMMODATE EXISTING WINDOW.

4 OVERHEAD STRUCTURALLY MOUNTED PATIENT LIFT RAIL AND TRACK SYSTEM. COORDINATE

SPRINKLER SYSTEM SPRINKLERS AND SPRINKLER PIPING WITH LIFT. DO NOT INSTALL PIPING IN A FASHION THAT WILL PREVENT PROPER OPERATION OF TRACK AND DO NOT INSTALL SPRINKLERS IN

A FASHION THAT WILL BE DAMAGED WITH EXPECTED OPERATION OF TRACK. DO NOT INSTALL

SPRINKLERS IN SPACE BETWEEN RAILS WHERE CROSS BAR OF LIFT TRAVELS. PROVIDE

ADDITIONAL SPRINKLERS IF NEEDED TO MEET THIS REQUIREMENT.

5 CEILING 7-3/4” HIGHER THAN ADJACENT CEILING GRID TO ACCOMMODATE EXISTING WINDOW.

PROTECT SPACE WITH SIDEWALL STYLE SPRINKLERS.

6 CEILING BULKHEAD EXTENDS 10” BELOW ADJACENT CEILING GRID.

7 CAP EXISTING 1” SPRINKLER BRANCH MAIN.

8 RECONNECT EXISTING TO REMAIN SPRINKLER BRANCH PIPING. FIELD VERIFY SIZE.

9 CEILING MOUNTED RADIANT HEATER.

1/8" = 1'-0"

FLOOR PLAN - 3RD FLOOR FIRE SUPPRESSION - AREA B

CONTRACTOR SHALL PATCH AND

REAPPLY ANY SPRAYED-ON

FIREPROOFING THAT IS REMOVED TO

C

FEC

FEC

F E

C F

E C

DN UP

SD

F

F

F

F

SD

SD

SD

SD

SD

SD

SD

F

F

F

SD

ABDEFGHJ

H.5

8.0

CORR.

C3A4

MEDS

A335

GEN. STOR.

A326

CLEAN

A336

SOILED

A337

CLEAN LINEN

A336A

NURSE

D314

MEDS

D315

SOILED

D316

ISO/BAR #1

A301

ISO/BAR #2

A302

ISO/BAR #3

A303

MEDS

A319

NOUR.

A324

NURSE MGR/

ASST MGR.

A325

PAT. RM #23

D323

PAT. RM #22

D322

PAT. RM #21

D321

BARIATRIC

#20

D320

ISO/BAR #19

D319

BARIATRIC

#18

A318

PAT. RM #17

A317

PAT. RM #16

A316

BARIATRIC

#15

A315

PAT. RM #14

A314

BARIATRIC

#13

A313

DIALYSIS

D342

TLT./SHWR

A313A

TLT./SHWR

A314A

TLT./SHWR

A315A

TLT./SHWR

A316A

TLT./SHWR

A317A

TLT./SHWR

A318A

TLT./SHWR

D319A

TLT./SHWR

D320A

TLT./SHWR

D321A

TLT./SHWR

D322A

NURSE

A328

TLT./SHWR

A302A

TLT./SHWR

A301A

ANTE

D319B

ANTE

A301B

ANTE

A302B ANTE

A303B

CORR.

C3A6

CORR.

C3D5

NURSE

WK/COPY

A329

TLT.

A338

SOILED

D342A

ELEC

D338

STAFF

LOUNGE

D343

LOCKER

D343A

TLT./SHWR

A303A

PAT. RM #6

D306

TLT./SHWR

D306A

PAT. RM #8

D308

PAT. RM #10

D310

PAT. RM #12

D312

TLT./SHWR

D312A

TLT./SHWR

D310A

TLT./SHWR

D308A

EQUIP

D311

TLT./SHWR

D304A

PAT. RM #4

D304

STRETCHER

D303

EQUIP.

D305

STRETCHER

D309

MED. GAS

D307

NOUR.

D313

MSA

D302

NURSE

A332

PAT. RM #11

A311

PAT. RM #9

A309

PAT. RM #7

A307

TLT./SHWR

A311A

TLT./SHWR

A309A

TLT./SHWR

A307A

ELEC./SYSTEMS

A330

CLEAN

A321

PAT. RM #5

A305

TLT./SHWR

A305A

CLEAN LINEN

A322SOILED

A320

NURSE

WK/COPY

A333

NOUR.

A334

CORR.

C3A2

CORR.

C3A3

CORR.

C3D4

STAIR #4

A346

STAIR #2

D340

STORAGE

A327

HSKPG

A331

CONSULT

RM.

D344

STORAGE

D345

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

S D

S D

S D

SD SD

S D

SD SD

S D

RTU-1 (LOCATED ON ROOF ABOVE)

DM

SD

DM

SD

R R

(SUPPLY)

(SUPPLY )

THIRD FLOOR KEY PLAN - AREA A

A

N

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

FA111

FLOOR PLAN - 3RD FLOOR FIRE

ALARM - AREA A

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

SCTEMN

N

KEYNOTES

1 EXISTING FIRE ALARM TRANSPONDER PANEL (FATC) AND NAC EXTENDER PANEL LOCATION. FATC

AND NAC PANELS SHALL REMAIN.

2 EXISTING FIRE ALARM SMOKE DETECTOR SHALL REMAIN.

3 EXISTING TAMPER AND FLOW SWITCHES SHALL REMAIN. COORDINATE RECONNECTING SWITCHES

AS REQUIRED FOR CONSTRUCTION WORK.

4 DOORS SHALL BE HELD OPEN BY INTEGRAL CLOSER FIRE ALARM HOLD OPEN AND SHALL BE

CONNECTED TO FIRE ALARM SYSTEM TO CLOSE UPON ACTIVATION OF DOOR RELEASE SMOKE

DETECTORS.

5 WHERE EXISTING CEILING WORK IS BEING COMPLETED ON SECOND FLOOR FOR ABOVE CEILING PLUMBING WORK, COORDINATE REMOVAL AND REINSTALLING/RECONNECTING ANY EXISTING FIRE

ALARM DEVICES THAT ARE CEILING MOUNTED AND ARE IMPACTED BY CEILING WORK.

6 APPROXIMATE LOCATION OF ROOM D019D, BASEMENT, LOCATION OF EXISTING SIEMENS MODEL

XLS FACP.

7 EXISTING SMOKE WALL BARRIER HAS BEEN RELOCATED. PROVIDE CONNECTIONS AS NECESSARY

TO SMOKE DAMPERS AT NEW SMOKE WALL BARRIER.

1/8" = 1'-0"

FLOOR PLAN - 3RD FLOOR FIRE ALARM - AREA A

CONTRACTOR SHALL PATCH AND

REAPPLY ANY SPRAYED-ON

FIREPROOFING THAT IS REMOVED TO

FACILITATE THE INSTALLATION OF

FIRE ALARM SYSTEM.

SEE SHEET FA112 FOR NEW SMOKE

ZONE BOUNDARIES AND

IDENTIFICATION REQUIREMENTS.

F E

C

FEC

FEC

F E

C F

F

F

SD

SD

FE

F E

FE

F E

F E

F E

FEC

F E

C

FEC

FEC

F E

C

F E

C

FEC

FEC

F E

C F

E C

DNUP

FD FD

F D

F D

FD

FD

FD FD FD FD

FD

FD

FD

FD

FD

FD

FD

FD

ABDEFGHJJb

H.5

SOILED

D316

CLEAN

D317

CLEAN LINEN

D317A

PAT. RM #24

D324

PAT. RM #23

D323

PT TLT.

D323A

TLT./SHWR

D324A

CORR.

C3D5

HSKPG

D326

TLT.

D318

ELEC

D338

CODER/REVIEW

D334

SWAMP #2

D332

SWAMP #3

D330

COPY

D336

TLT.

D341

CHG ROOM

D343B

SHARED

OFFICE

D335

WAD

D339

OFFICE

D333

HOSPITALIST

D328

SWAMP #1

D331

SWAMP #4

D329

CORR.

C3D3

SOCIAL

D337

LOCKER

D343A

STAIR #5

D325

STAIR #6

D327

CORR.

C3C4

(TYP)

SD SDSD

THIRD FLOOR KEY PLAN - AREA B

BN

S C

-4

S C

-3

SC3-2

SC3-1

SC3-3

SC3-5

SC3-2

SC3-5

S C

-3

S C

-2

SC

3-4

SC

3-3

SC

3-2

SC

3-1

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

FA112

FLOOR PLAN - 3RD FLOOR FIRE

ALARM - AREA B

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

SCTEMN

N

KEYNOTES

1 WHERE EXISTING CEILING WORK IS BEING COMPLETED ON SECOND FLOOR FOR ABOVE CEILING PLUMBING WORK, COORDINATE REMOVAL AND REINSTALLING/RECONNECTING ANY EXISTING FIRE

ALARM DEVICES THAT ARE CEILING MOUNTED AND ARE IMPACTED BY CEILING WORK.

2 APPROXIMATE LOCATION OF ROOM D019D, BASEMENT, LOCATION OF EXISTING SIEMENS MODEL

XLS FACP.

3 DOORS SHALL BE HELD OPEN BY INTEGRAL CLOSER FIRE ALARM HOLD OPEN AND SHALL BE

CONNECTED TO FIRE ALARM SYSTEM TO CLOSE UPON ACTIVATION OF DOOR RELEASE SMOKE

DETECTORS.

4 PROVIDE CONNECTIONS TO NEW TAMPER AND FLOW SWITCHES. REFER TO FIRE SUPPRESSION

PLANS AND SECTIONS FOR ADDITIONAL INFORMATION. COORDINATE CONNECTIONS WITH FIRE

SPRINKLER CONTRACTOR.

1/8" = 1'-0"

FLOOR PLAN - 3RD FLOOR FIRE ALARM - AREA A

CONTRACTOR SHALL PATCH AND

REAPPLY ANY SPRAYED-ON

FIREPROOFING THAT IS REMOVED TO

FACILITATE THE INSTALLATION OF

FIRE ALARM SYSTEM.

1" = 40'-0"

FLOOR PLAN - 3RD FLOOR SMOKE ZONES - OVERALL

3RD LEVEL

762' - 5 1/4"

3RD LEVEL

762' - 5 1/4"

THIRD FLOOR - ACA

769' - 0 1/2"

THIRD FLOOR - ACA

769' - 0 1/2"

1.1

3RD LEVEL

26' - 5 1/4"

3RD LEVEL

26' - 5 1/4"

4TH LEVEL

39' - 1 1/4"

4TH LEVEL

39' - 1 1/4"

1.1

3RD LEVEL

26' - 5 1/4"

3RD LEVEL

26' - 5 1/4"

4TH LEVEL

39' - 1 1/4"

4TH LEVEL

39' - 1 1/4"

B

2ND LEVEL

13' - 9 1/4"

2ND LEVEL

13' - 9 1/4"

3RD LEVEL

26' - 5 1/4"

3RD LEVEL

26' - 5 1/4"

4TH LEVEL

39' - 1 1/4"

4TH LEVEL

39' - 1 1/4"

B

TO ZONE 19

SPRINKLERS

3RD LEVEL

26' - 5 1/4"

3RD LEVEL

26' - 5 1/4"

4TH LEVEL

39' - 1 1/4"

4TH LEVEL

39' - 1 1/4"

THIRD FLOOR - ACA

33' - 0 1/2"

THIRD FLOOR - ACA

33' - 0 1/2"

THIRD FLOOR - ACA

769' - 0 1/2"

THIRD FLOOR - ACA

769' - 0 1/2"

8.2 8.38.0

3RD LEVEL

26' - 5 1/4"

3RD LEVEL

26' - 5 1/4"

4TH LEVEL

39' - 1 1/4"

4TH LEVEL

39' - 1 1/4"

THIRD FLOOR - ACA

33' - 0 1/2"

THIRD FLOOR - ACA

33' - 0 1/2"

THIRD FLOOR - ACA

769' - 0 1/2"

THIRD FLOOR - ACA

769' - 0 1/2"

8.2 8.3

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:202054

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

07/26/2021

F-300

FIRE PROTECTION SECTIONS

RELOCATE MEDICAL WARD

FOR PATIENT PRIVACY

800 HOSPITAL DRIVE COLUMBIA, MO 65201

07-26-2021

589A4-21-100

100% CONSTRUCTION DOCUMENTS

MKMDGK

1/2" = 1'-0"

ZONE 18 - 3RD FLOOR RISER DEMOLITION

1/2" = 1'-0"

ZONE 18 RISER - 3RD FLOOR STAIR #4

1/2" = 1'-0"

ZONE 19 RISER - DEMOLITION

1/2" = 1'-0"

ZONE 19 RISER - 3RD FLOOR STAIR #5

1/2" = 1'-0"

ZONE 23 - 3RD FLOOR RISER DEMOLITION

1/2" = 1'-0"

ZONE 23 - 3RD FLOOR RISER STAIR #2

KEYNOTES

1 EXISTING 4” SPRINKLER MAIN TO REMAIN.

2 EXISTING 1-1/2” MAIN DRAIN TO REMAIN.

3 EXISTING ZONE 18 CONTROL ASSEMBLY. SEE SHEET FD110 FOR AREA SERVED BY THIS ZONE OF

SPRINKLERS.

4 REMOVE ALL ZONE 18 FIRE SPRINKLER SYSTEM FROM POINT OF CONNECTION TO THE EXTENT OF THE SYSTEM WITH THE EXCEPTION OF THE PIPING AND SPRINKLERS SERVING STAIR TOWER #4 AS

SHOWN ON SHEET FD111. SEE NEW RISER SECTION 2 ON THIS SHEET AND SHEETS FX110 AND

FX111 FOR NEW SYSTEM REQUIREMENTS FOR ZONE 18.

5 PROVIDE NEW ZONE 18 FIRE SPRINKLER SYSTEM STARTING AT POINT OF CONNECTION SHOWN.

SEE SHEET FX110 FOR AREA TO BE SERVED BY THIS ZONE OF SPRINKLERS. SEE SHEET FX111 FOR ADDITIONAL DESIGN REQUIREMENTS FOR THIS ZONE OF SPRINKLERS. RECONNECT EXISTING 1”

BRANCH SERVING STAIR #4 SPRINKLERS TO NEW ZONE 18 PIPING. FIELD VERIFY EXISTING

CONDITIONS PRIOR TO CREATION OF SHOP DRAWING SUBMITTAL.

6 REMOVE ALL ZONE 19 FIRE SPRINKLER SYSTEM FROM POINT OF CONNECTION TO THE EXTENT OF THE SYSTEM WITH THE EXCEPTION OF THE PIPING AND SPRINKLERS SERVING STAIR TOWER #5 AS

SHOWN ON SHEET FD112. SEE NEW RISER SECTION 4 ON THIS SHEET AND SHEETS FX110 AND

FX112 FOR NEW SYSTEM REQUIREMENTS FOR ZONE 19.

7 REMOVE ALL EXISTING DRAIN FROM POINT OF CONNECTION TO ZONE CONTROL ASSEMBLY TO

POINT OF DISCONNECT SHOWN.

8 DISCONNECT 1” BRANCH MAIN AT POINT OF DISCONNECT SHOWN FOR SPRINKLERS SERVING STAIR

#5. RECONNECT TO NEW ZONE 19 PIPING. FIELD VERIFY EXISTING CONDITIONS.

9 CONNECT TO EXISTING 4” SPRINKLER MAIN TO SERVE NEW ZONE 19 SPRINKLER SYSTEM. SEE

SHEET FX110 FOR NEW ZONE 19 AREA TO BE SERVED AND SEE SHEETS FX111 AND FX112 FOR

ADDITIONAL DESIGN REQUIREMENTS FOR THIS ZONE OF SPRINKLERS.

10 PROVIDE NEW ZONE CONTROL ASSEMBLY PER DETAIL 2 ON SHEET F-001. COORDINATE FIRE

ALARM REQUIREMENTS WITH FIRE ALARM INSTALLING CONTRACTOR.

11 RECONNECT NEW ZONE CONTROL DRAIN PIPING TO EXISTING AT POINT OF CONNECTION SHOWN.

12 RECONNECT EXISTING 1” BRANCH MAIN SERVING STAIR #5 SPRINKLERS TO NEW ZONE 19 SYSTEM.

FIELD VERIFY EXISTING CONDITIONS PRIOR TO CREATION OF SHOP DRAWING SUBMITTAL.

13 EXISTING 6” COMBINATION STANDPIPE AND SPRINKLER MAIN TO REMAIN.

14 EXISTING 2” DRAIN PIPE TO REMAIN.

15 EXISTING 2-1/2” HOSE VALVE TO REMAIN.

16 EXISTING ZONE 23 CONTROL VALVE ASSEMBLY TO REMAIN. SEE SHEET FD110 FOR AREA SERVED

BY THIS ZONE OF SPRINKLERS.

17 REMOVE ALL EXISTING ZONE 23 ZONE OF SPRINKLERS FROM THE POINT OF DISCONNECT SHOWN

THROUGH THE RENOVATION AREA. SEE SHEETS FD111 AND FD112 FOR EXTENT OF REMOVAL.

18 PROVIDE NEW ZONE 23 SPRINKLER PIPING FOR AREAS LOCATED WITHIN RENOVATION SPACE.

RECONNECT ALL EXISTING PIPING TO NEW SYSTEM AS SHOWN ON DRAWING SHEETS FX111 AND

FX112. SEE SHEET FX110 FOR NEW AREA SERVED BY THIS ZONE OF SPRINKLERS.

201704 Relocate Medical Ward - Sheet - AE601 - SCHEDULES.pdf
Sheets
AE601 - SCHEDULES