589A4-21-100 SIGNED DRAWINGS R1_Part1.pdf
PDF 18 MB Posted
- Solicitation number
- 36c25522R0024
About this file
This solicitation is for a federal contract opportunity to relocate a medical ward for patient privacy at a Veterans Affairs medical center. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15 is seeking proposals to provide specifications and drawings as outlined in solicitation number 36c25522R0024 and product number 589A4-21-100. Offerors should submit responses by the deadline specified to relocate the existing medical ward and ensure patient privacy through architectural drawings and updated building specifications. The selected contractor will be responsible for designing and documenting the new layout and construction requirements to improve privacy for patients at the facility.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MEDICAL CENTER DIRECTOR
DOCUMENT SIGNATURE BLOCK
PRINT NAME SIGNATURE
ASSOCIATE DIRECTOR
PRINT NAME SIGNATURE
ASSOCIATE DIRECTOR OF PATIENT SERVICES
PRINT NAME SIGNATURE
ASSISTANT DIRECTOR
PRINT NAME SIGNATURE
CHIEF ENGINEER
PRINT NAME SIGNATURE
INFECTION CONTROL PRACTITIONER
PRINT NAME SIGNATURE
SAFETY OFFICER
PRINT NAME SIGNATURE
CHIEF OF STAFF
PRINT NAME SIGNATURE
HRO DIRECTOR
PRINT NAME SIGNATURE
ABBREVIATIONS
PROJ(D)
PLBG
PLYWD
PREFIN
RAD(R)
RESIL
REINF
REQ'D
SECT
SHWR
SPECS
REFRIG
GALVANIZEDGALVBMRK BENCHMARK
CONCRETE
MASONRY UNIT
CEILINGCLG
CLR
CMU
COL
CLO
CLEAR/CLEARANCE
COLUMN
CLOSET
CAB
CJ
CC
CB
BW
CL
BOC
BRZ
BRK
BO
BRG
BUR
BTM
BS
BUILT-UP ROOF
CENTER TO CENTER
CHALKBOARD
BOTTOM OF WALL
CENTER LINE
CONTROL JOINT/
CONSTRUCTION JOINT
CABINET
BACK OF CURB
BOTH SIDES
BOTTOM OF
BRONZE
BRICK
BEARING
BOTTOM
FOUNDATION
FLOOR DRAIN
FIRE EXTINGUISHER
FIRE
EXTINGUISHER
CABINET
FE
FEC
FDN
FD
EAST
EACH
EQUIPMENT
EXPOSED
EACH WAY
EXISTING
ELECTRICAL
EXTERIOR INSULATION
FINISH SYSTEM
ELEVATION/ELEVATOR
EXPANSION JOINT
EXISTING GRADE
ELECTRICAL CONTRACTOR
EXTERIOR
ETHYLENE PROPYLENE
DIENE TERPOLYMER
ELEV
EQUIP
EW
EPDM
EXP
EXIST
EXT
E
EA
EC
EG
EIFS
EJ
ELEC
INSULATION
INTERIOR
INSIDE DIAMETER
INSUL
IN(")
INT
ID
INCH
GRAB BAR
GENERAL CONTRACTOR
GYPSUM
GLASS/GLAZING
HOLLOW METAL
HIGH PRESSURE
DECORATIVE LAMINATE
HORIZONTAL
HARDWARE
HARDWOOD
HOSE BIB
HOT WATER
HEATING, VENTILATING
& AIR CONDITIONING
HDWR
HM
HORZ
HT
HPDL
HVAC
HW
HEIGHT
GB
GL
GRD
GYP
GC
HDWD
HB
GRADE
PART
PLAS
OVHD
PARTITION
PLASTER
OVERHEAD
SRT
SS
SQ
MISCELANEOUS
MASONRY OPENING
NOT IN CONTRACT
NOT APPLICABLE
OUTSIDE DIAMETER
NUMBERNO(#)
NTS
OC
OA
NOM
OFF
OPNG
OD
ON CENTER
OVERALL
NOMINAL
NOT TO SCALE
OFFICE
OPENING
MISC
N
MO
MULL
MTL
NIC
NA
NORTH
MULLION
METAL
SHT
SF
SB
SND
SIM
S
RM
ROW
RO
SAT
SAN
ARCHITECT/
ARCHITECTURAL
AB ANCHOR BOLT
APPROX
BLDG
BD
ARCH
BM
BLK
ADJ
AFF
AC
ACCU
ALUM
ANOD
ALT
APPROXIMATE
BLOCK/BLOCKING
AT
BOARD
BEAM
BUILDING
AIR COOLED
CONDENSING UNIT
ABOVE FINISHED FLOOR
ADJUSTABLE
ALTERNATE
ANODIZED
ACOUSTICAL
ALUMINUM
A/C AIR CONDITIONING
PLUS OR MINUS
CONSTRUCTIONCONST
COURSE
CERAMIC TILE
CONTINUOUS
CARPET
CORRIDOR
DIAMETER
DOOR
DOWN
DITTO
DIMENSION
DOUBLE
DRINKING FOUNTAIN
DETAIL
DRAWING
DOWNSPOUT
DIA
DR
DS
DN
DO
DIM
DTL
DWG
CRS
CT
CONT
CORR
CPT
DBL
DF
CONFERENCE
CONCRETE
CONF
CONC
FINISHFIN
FLUORESENT
FLOW LINE
FOLDING
FIELD VERIFY
FURNACE
FOOTING
FIRE RETARDANT
FOOT SCRAPER
FIBERGLASS
REINFORCED PLASTIC
FV
FT(')
FURR
FURN
FTG
G
GA
FOOT
FURRING
GAS
GUAGE
FRP
FLR
FLDG
FL
FRT
FS
FLUOR
FLOOR
FINISH GRADE
FINISH FLOOR
FG
FF
JOISTJST
LOW VOLUMN CHANGE
MASONRYMAS
MANUF
MATL
MAX
MECH
MEMB
MH
MIN
MIRR
MANUFACTURER
MATERIAL
MECHANICAL
MEMBRANE
MAXIMUM
MINIMUM
MANHOLE
MIRROR
LDR
LF
LAV
LAM
LVC
LOCN
LINEAL FEET
LADDER
LAVATORY
LAMINATE
LOCATION
REF
R
RAG
RD
PT
PR
QT
PTD
JT
JAN JANITOR
JOINT
PL
UNDER CABINET LIGHTREQUIRED
PHYSICAL THERAPY
RESPIRATORY CARE
SURGICAL INTENSIVE CARE UNIT
STUDDED RUBBER TILE
STAINLESS STEEL
SQUARE
SPECIFICATIONS
YD
SUSPENDED
ACOUSTICAL TILE
SIMILAR
SANITARY NAPKIN
DISPENSER
SECTION
SHOWER
SHEET
SQUARE FEET
SPLASH BLOCK
RESILIENT
SOUTH
SANITARY
RIGHT OF WAY
ROUGH OPENING
ROOM
WD
WNDW
WH
WNSCT
WC
WT
WWF
WP
VCT
VWC
VEST
VERT
W
W/
W/O
YARD
WATERPROOFING
/WATERPROOF
WELDED WIRE FABRIC
WATER HEATER
WATER CLOSET
WINDOW
WOOD
WAINSCOT
WEIGHT
VINYL COMPOSITION TILE
VINYL WALL COVERING
VERTICAL
VESTIBULE
WEST
WITH
WITH OUT
RC
SICU
CENTRAL STERILE
LONG TERM CARE
INTENSIVE CARE UNIT
OCCUPATIONAL THERAPY
MAGNETIC RESONANCE IMAGING
POST ANESTHETIC CARE UNIT
MEDICAL INTENSIVE CARE UNIT
LABOR-DELIVERY-RECOVERY-POST PARTUM
OPERATING ROOM
FOR MEDICAL
FACILITIES ONLY
EMERGENCY ROOM
COMPUTED TOMOGRAPHY
STORPLUMBING
PROJECT/(PROJECTED)
REFER/REFERENCE
ROOF DRAIN
RADIUS
RETURN AIR GRILLE
REINFORCING
REFRIGERATOR
RISER
PRESSURE TREATED
PAINTED
QUARRY TILE
PLYWOOD
PREFINISHED
PAIR
TLT
TV
TW
TOC
TPH
TO
TYP
UCL
T&B
T
SUSP
STRUCT
TEL
TB
T&G
PLATE/PLASTIC/
PROPERTY LINE STL
STD
STORAGE
TOILET PAPER HOLDER
TOP OF CURB
TOILET
TELEVISION
TOP OF
TYPICAL
TOP OF WALL
TONGUE & GROOVE
TOP & BOTTOM
STRUCTURE/STRUCTURAL
TREAD
TELEPHONE
TACKBOARD
SUSPENDED
ICU
OR
LDRP
MRI
MICU
LTC
PT
PACU
OT
CS
CT
ER
STEEL
STANDARD
CUT STONE
STEEL
PLYWOOD
FINISH WOOD
CONT WD FRAMING
WOOD BLOCKING
MATERIAL SYMBOLS
LVC FILL
GRANULAR FILL
CONCRETE MASONRY
FACE BRICK
CONCRETE
EARTH
EXISTING CONSTRUCTION
ASPHALT
GLASS
RIGID OR TAPERED
INSULATION, EIFS
BATT INSULATION
GYPSUM BOARD
DRAWING SYMBOLS
95.00
TOC
98.5
TOC
98.5 E
B
NEW ELEVATION
EXISTING ELEVATION
EXISTING CONTOUR
NEW CONTOUR
TEST BORING (SITE PLANS ONLY)
EXISTING ELEVATION
EXISTING ELEVATION
PROPERTY LINE
/1 A101
/1 A101
MATCHLINE
SHT. REFERENCE
ELEVATION DATUM
(SECTIONS, ELEVATIONS ONLY)
BUILDING SECTION
WALL SECTION
DETAIL DRAWING
AS-201
BUILDING ELEVATION
AI-201 INTERIOR ELEVATION
A100
WINDOW ID TAG
DOOR NUMBER
ROOM NAME
ROOM NAME & NUMBER
PARTITION SYMBOL
1 REVISION TAG
COLUMN LINE GRID
ME100E EQUIPMENT NUMBER
? SITE PLAN NOTES
DEMOLITION PLAN NOTES
VICINITY MAP
NO SCALE
PRECAST CONCRETE
WALL PANEL TAG
XXX
AS-101
A-4 ALTERNATE TAG
PT-XX PAINT COLOR TAG
# PLAN NOTES &
ROOF PLAN NOTES
PROJECT
LOCATION
REFERENCE SECTION 010000 GENERAL REQUIREMENTS ITEM 1.3 STATEMENT OF BID ITEMS.
BID ITEM 1 (BASE BID) INCLUDES ALL SCOPE COMMUNICATED IN THE DRAWINGS AND SPECIFICATIONS.
BID ITEMS
BID ITEM 2 (DEDUCT): INCLUDES ALL WORK IN BID ITEM 1 WITH THE FOLLOWING EXCEPTIONS (ALL ITEMS BELOW TO BE BID AS ONE DEDUCT):
2A. OMIT ALL SCOPE OF WORK RELATED TO THE ROOF FALL PROTECTION SYSTEM.
BID ITEM 3 (DEDUCT): INCLUDES ALL WORK IN BID ITEM 2 WITH THE FOLLOWING EXCEPTIONS:
3. OMIT ALL SCOPE OF WORK RELATED TO THE PATIENT LIFT, REF. SPEC AND RCP (DEDUCT W/ BID DEDUCT #3) SYSTEM IN ALL
PATIENT ROOMS AND TOILETS, CORRIDOR C3A6, AND DIALYSIS D334
2B. OMIT ALL SCOPE OF WORK RELATED TO CREATING THE NEW ROOF ACCESS.
2C. OMIT ALL SCOPE OF WORK RELATED TO NEW RTU SCREEN WALL.
2D. OMIT ALL SCOPE OF WORK RELATED TO DEMOLITION OF 3RD FLOOR PATIO AND CANOPY, WITH THE EXCEPTION OF
PATIO ACCESS DOOR TO BE DEMOLISHED AND INFILL WITH WINDOW TYPE W1.
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
GI001
TITLE SHEET
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
RELOCATE MEDICAL WARD FOR PATIENT PRIVACY
HARRY S. TRUMAN MEMORIAL VETERANS' HOSPITAL
DEPT OF VETERANS AFFAIRS
800 HOSPITAL DRIVE COLUMBIA, MO 65201
FINAL CONSTRUCTION DOCUMENTS
FINAL CONSTRUCTION DOCUMENTS
589A4-21-100
SHEET INDEX
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES AND SYMBOLS
ED121 ELECTRICAL DEMOLITION PLAN - 2ND FLOOR - AREA A
ED131 ELECTRICAL DEMOLITION PLAN - 3RD FLOOR - AREA A
ED132 ELECTRICAL DEMOLITION PLAN - 3RD FLOOR - AREA B
EL131 ELECTRICAL LIGHTING PLAN - 3RD FLOOR - AREA A
EL132 ELECTRICAL LIGHTING PLAN - 3RD FLOOR - AREA B
EL141 ELECTRICAL LIGHTING PLAN - 4TH FLOOR - AREA A
EL141.2 ELECTRICAL LIGHTING PLAN - 4TH FLOOR - AREA A - BID ITEM #2 (DEDUCT)
EL431 ELECTRICAL ENLARGED LIGHTING PLANS
EL432 ELECTRICAL ENLARGED LIGHTING PLANS
EL501 ELECTRICAL LIGHTING DETAILS AND SCHEDULES
EP101 ELECTRICAL POWER PLAN - BASEMENT
EP131 ELECTRICAL POWER PLAN - 3RD FLOOR - AREA A
EP132 ELECTRICAL POWER PLAN - 3RD FLOOR - AREA B
EP141 ELECTRICAL POWER PLAN - ROOF
EP431 ELECTRICAL ENLARGED POWER PLANS
EP432 ELECTRICAL ENLARGED POWER PLANS
EP501 ELECTRICAL POWER DETAILS
EP601 ELECTRICAL PARTIAL ONE-LINE DIAGRAM
EP602 ELECTRICAL POWER SCHEDULES
EP603 ELECTRICAL POWER SCHEDULES
EY131 ELECTRICAL SYSTEMS PLAN - 3RD FLOOR - AREA A
EY132 ELECTRICAL SYSTEMS PLAN - 3RD FLOOR - AREA B
EY431 ELECTRICAL ENLARGED SYSTEMS PLANS
EY432 ELECTRICAL ENLARGED SYSTEMS PLANS
EY501 ELECTRICAL SYSTEMS DETAILS AND SCHEDULES
SHEET INDEX
STRUCTURAL
S-001 GENERAL NOTES
S-101 FRAMING PLAN - 3RD FLOOR
S101.2 FRAMING PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)
S-201 FRAMING PLAN - 4TH FLOOR & ROOF
S201.2 FRAMING PLAN - 4TH FLOOR & ROOF - BID ITEM #2 (DEDUCT)
S-510 TYPICAL FRAMING DETAILS
S-511 TYPICAL FRAMING DETAILS
FIRE SUPPRESION AND ALARM
F-001 FIRE SUPPRESSION GENERAL NOTES & DETAILS
F-002 FIRE ALARM SYMBOLS, GENERAL NOTES & DETAILS
FD101 DEMOLITION PLAN - 2ND FLOOR FIRE SUPPRESSION - AREA A
FD102 DEMOLITION PLAN - 2ND FLOOR FIRE SUPPRESSION - AREA B
FD110 DEMOLITION PLAN - 3RD FLOOR FIRE SUPPRESSION - OVERALL
FD111 DEMOLITION PLAN - 3RD FLOOR FIRE SUPPRESSION - AREA A
FD112 DEMOLITION PLAN - 3RD FLOOR FIRE SUPPRESSION - AREA B
FD211 DEMOLITION PLAN - 3RD FLOOR FIRE ALARM - AREA A
FD212 DEMOLITION PLAN - 3RD FLOOR FIRE ALARM - AREA B
FX101 FLOOR PLAN - 2ND FLOOR FIRE SUPPRESSION - AREA A
FX102 FLOOR PLAN - 2ND FLOOR FIRE SUPPRESSION - AREA B
FX110 FLOOR PLAN - 3RD FLOOR FIRE SUPPRESSION - OVERALL
FX111 FLOOR PLAN - 3RD FLOOR FIRE SUPPRESSION - AREA A
FX112 FLOOR PLAN - 3RD FLOOR FIRE SUPPRESSION - AREA B
FA111 FLOOR PLAN - 3RD FLOOR FIRE ALARM - AREA A
FA112 FLOOR PLAN - 3RD FLOOR FIRE ALARM - AREA B
F-300 FIRE PROTECTION SECTIONS
PLUMBING
P-001 PLUMBING COVER SHEET
PD101 PLUMBING DEMOLITION PLAN - 2ND FLOOR- AREA A
PD102 PLUMBING DEMOLITION PLAN - 2ND FLOOR - AREA B
PD103 PLUMBING DEMOLITION PLAN - 3RD FLOOR - AREA A
PD104 PLUMBING DEMOLITION PLAN - 3RD FLOOR - AREA B
PD201 MEDICAL GAS DEMOLITION PLAN - 3RD FLOOR - AREA A
PD202 MEDICAL GAS DEMOLITION PLAN - 3RD FLOOR - AREA B
PL101 PLUMBING PLAN - 2ND FLOOR - AREA A
PL102 PLUMBING PLAN - 2ND FLOOR - AREA B
PL103 PLUMBING PLAN - 3RD FLOOR - AREA A
PL104 PLUMBING PLAN - 3RD FLOOR - AREA B
PL105 PLUMBING ROOF PLAN
PL201 MEDICAL GAS PLAN - 3RD FLOOR - AREA A
PL202 MEDICAL GAS PLAN - 3RD FLOOR - AREA B
PL401 ENLARGED PLUMBING PLAN - 3RD FLOOR
PL402 ENLARGED PLUMBING PLAN - 3RD FLOOR
PL403 ENLARGED PLUMBING PLAN - 3RD FLOOR
PL404 ENLARGED PLUMBING PLAN - 3RD FLOOR
PL405 ENLARGED PLUMBING PLANS AND RISERS
PL406 ENLARGED PLUMBING PLANS AND RISERS
PL407 ENLARGED PLUMBING PLANS AND RISERS
P-601 PLUMBING SCHEDULES AND DETAILS
MECHANICAL
M-001 MECHANICAL COVER SHEET
MD101 HVAC DEMOLITION PLAN - 2ND FLOOR - AREA A
MD111 HVAC DEMOLITION PLAN - 3RD FLOOR - AREA A
MD112 HVAC DEMOLITION PLAN - 3RD FLOOR - AREA B
MD121 HVAC DEMOLITION PLAN - 4TH FLOOR
MD121.2 HVAC DEMOLITION PLAN - 4TH FLOOR - BID ITEM #2 (DEDUCT)
MD211 HYDRONIC DEMOLITION PLAN - 3RD FLOOR - AREA A
MD212 HYDRONIC DEMOLITION PLAN - 3RD FLOOR - AREA B
MH101 HVAC PLAN - 3RD FLOOR - RATING COORDINATION
MH111 HVAC PLAN - 3RD FLOOR - AREA A
MH111.2 HVAC PLAN - 3RD FLOOR - AREA A - BID ITEM #2 (DEDUCT)
MH112 HVAC PLAN - 3RD FLOOR - AREA B
MH121 HVAC PLAN - ROOF
MP101 HYDRONIC PLAN - BASEMENT, 1ST & 2ND FLOOR
MP111 HYDRONIC PLAN - 3RD FLOOR - AREA A
MP112 HYDRONIC PLAN - 3RD FLOOR - AREA B
MJ101 AHU SERVICE AREAS AND AIRFLOW DIAGRAM
M-501 STEAM DETAILS
M-502 STEAM AND HYDRONIC DETAILS
M-503 MECHANICAL DETAILS
M-504 MECHANICAL DETAILS
M-511 AHU CONTROL DETAIL
M-512 CONTROL DETAILS
M-513 CONTROL DETAILS
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
SHEET INDEX
GENERAL
GI001 TITLE SHEET
GI002 ABA SHEET
GI003 LIFE SAFETY PLANS
GI004 PHASING PLAN - 2ND & 4TH FLOORS
GI005 PHASING PLAN - 3RD FLOOR
HA101 HAZARDOUS MATERIAL PLAN
ARCHITECTURAL
AD101 DEMOLITION - PATIO
AD102 DEMOLITION PLAN - 2ND FLOOR - ABOVE CEILING
AD103 DEMOLITION PLAN - 3RD FLOOR - PENETRATIONS
AD104 DEMOLITION PLAN - 3RD FLOOR - OVERALL
AD104.2 DEMOLITION PLAN - 3RD FLOOR - OVERALL - BID ITEM #2 (DEDUCT)
AD105 DEMOLITION PLAN - 3RD FLOOR - AREA A
AD105.2 DEMOLITION PLAN - 3RD FLOOR - AREA A - BID ITEM #2 (DEDUCT)
AD106 DEMOLITION PLAN - 3RD FLOOR - AREA B
AD106.2 DEMOLITION PLAN - 3RD FLOOR - AREA B - BID ITEM #2 (DEDUCT)
AD107 DEMOLITION PLAN - 3RD FLOOR CEILING - AREA A
AD107.2 DEMOLITION PLAN - 3RD FLOOR CEILING - AREA A - BID ITEM #2 (DEDUCT)
AD108 DEMOLITION PLAN - 3RD FLOOR CEILING - AREA B
AD109 DEMOLITION PLAN - ROOF - AREA A
AE101 FLOOR PLAN - 3RD FLOOR - OVERALL
AE102 FLOOR PLAN - 3RD FLOOR - AREA A
AE103 FLOOR PLAN - 3RD FLOOR - AREA B
AE104 FLOOR PLAN - DIMENSIONS - 3RD FLOOR - AREA A
AE105 FLOOR PLAN - DIMENSIONS - 3RD FLOOR - AREA B
AE110 REFLECTED CEILING PLAN - 3RD FLOOR - AREA A
AE110.3 REFLECTED CEILING PLAN - 3RD FLOOR - AREA A - BID ITEM #3 (DEDUCT)
AE111 REFLECTED CEILING PLAN - 3RD FLOOR - AREA B
AE111.3 REFLECTED CEILING PLAN - 3RD FLOOR - AREA B - BID ITEM #3 (DEDUCT)
AE120 ROOF PLAN
AE120.2 ROOF PLAN - BID ITEM #2 (DEDUCT)
AE201 EXTERIOR ELEVATIONS
AE201.2 EXTERIOR ELEVATIONS - BID ITEM #2 (DEDUCT)
AE301 BUILDING SECTIONS
AE301.2 BUILDING SECTIONS - BID ITEM #2 (DEDUCT)
AE401 ENLARGED PLANS
AE402 ENLARGED PLANS - PATIENT TOILETS
AE403 ENLARGED PLANS - PATIENT TOILETS
AE410 ENLARGED RCP - PATIENT TOILETS
AE501 DETAILS
AE601 SCHEDULES
ARCHITECTURAL INTERIORS
AI101 FINISH SCHEDULE
AI102 FINISH PLAN - 3RD FLOOR - AREA A
AI103 FINISH PLAN - 3RD FLOOR - AREA B
AI201 EQUIPMENT SCHEDULE - 3RD FLOOR
AI202 EQUIPMENT PLAN - 3RD FLOOR - AREA A
AI203 EQUIPMENT PLAN - 3RD FLOOR - AREA B
AI204 ENLARGED EQUIPMENT PLAN - 3RD FLOOR - AREA A
AI301 WALL PROTECTION PLAN - 3RD FLOOR - AREA A
AI302 WALL PROTECTION PLAN - 3RD FLOOR - AREA B
AI401 SIGNAGE PLAN - 3RD FLOOR - AREA A
AI402 SIGNAGE PLAN - 3RD FLOOR - AREA B
AI501 MILLWORK SECTION DETAILS
AI502 MILLWORK SECTION DETAILS
AI701 INTERIOR ELEVATIONS
AI702 INTERIOR ELEVATIONS
AI703 INTERIOR ELEVATIONS
AI704 INTERIOR ELEVATIONS
AI705 INTERIOR ELEVATIONS
AI706 INTERIOR ELEVATIONS
AI707 INTERIOR ELEVATIONS & TILE DETAILS
N
Jesse Bell Snapshot
Jesse Bell Snapshot
WHEELCHAIR MANEUVERING
TURNING - PER VA GUIDELINES
CLEAR
2' - 6"
5' - 0"
1' - 0" 3' - 0"
1' - 0"
T-SHAPED
90 TURN 180 TURNS
60"
X < 48"
60"
48" 48"
60"
X < 48"
GENERAL NOTES
1. ALL CONSTRUCTION & RENOVATION SHALL MEET THE ARCHITECTURAL BARRIERS ACT
ACCESSIBILITY STANDARD (ABAAS).
2. SUPPLEMENTAL TO THE (ABAAS), CONSTRUCTION & RENOVATION IN HEALTH FACILITIES OF THE
DEPARTMENT OF VETERAN AFFAIRS (VA) SHALL COMPLY WITH THE BARRIER FREE DESIGN
GUIDE: A SUPPLEMENT TO THE ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS
(PG-18-13).
5' - 6"
NO SCALE
NO SCALENO SCALE
MANEUVERING CLEARANCES AT DOORS
LATCH SIDE APPROACHLATCH SIDE APPROACH
HINGE SIDE APPROACH
HINGE SIDE APPROACH
FRONT APPROACHFRONT APPROACH
Y
M
IN
.X
24" MIN.
X
Y
Y
M
IN
X
24" MIN.
X
M
IN
M
IN
18" MIN.
24" PREF.
54" MIN.
Y
M
IN
NOTE: Y=48" MIN. IF DOOR
HAD BOTH A LATCH AND
CLOSER
PATIENT BEDROOM MIN. DOOR WIDTH: 3'-10"
NOTE: X=12" IF
DOOR HAS BOTH A
CLOSER AND LATCH
NOTE: X=36" MIN. IF Y=60",
X=42" MIN. IF Y=54"
NOTE: Y=48" MIN. IF
DOOR HAS CLOSER
NOTE: Y=54" MIN. IF
DOOR HAS CLOSER
PULL SIDE
PUSH SIDE
PULL SIDE PUSH SIDEPUSH SIDE
NO SCALE
MEDICAL EQUIPMENT MOUNTING HEIGHTS
MEDICAL GAS
ZONE VALVE
NURSE CALL -
PATIENT TOILET
(DO NOT MOUNT
BEHIND TOILET)
CORD
ROBE HOOK
CALL STATION/
FLUSH-MOUNTED
STATION
RETURN AIR
REGISTER
O
R
FILM
ILLUMINATOR
RECEPTACLE
& GROUND
GROUND
FAULT
INDICATOR
REMOTE
GROUND
INDICATOR
VARIABLE
INTENSITY O.R.
LIGHT CONTROL
NITROGEN
SHUT-OFF
VALVE
O.R. RECEPTACLE
CODE BLUE
SWITCH
CLOCK
NO SCALE
SHARPS
CONTAINER
54" AFF TO
SLOT
GENERAL REACH DIMENSIONS
MOUNTING HEIGHT DIMENSIONS
MIRROR URINAL
TELEPHONE
CLOCK
LIGHT SWITCH
M A
X
M
A X
"6
M
A X
M
A X
M
A X
1'-2"
(TO HIGHEST
OPERABLE PART)
TOILET PAPER
DISPENSER
SANITARY NAPKIN
DISPOSAL
PAPER TOWEL
DISPENSER
OCCUPANCY SIGN
LATCH SIDE PREFERRED
THERMOSTAT
OR OTHER
CONTROL
48"
M
IN
Z
48"
Y
X 30" 24"
M
A X
30"
10" MAX
21" MAX
M
IN
M
A X
36" MIN
M
IN
M
A X
NOTE: X SHALL BE < 25";
Z SHALL BE > X, WHEN X < 20",
THEN Y SHALL BE 48" MAX
WHEN X IS 20"-25",
THEN Y SHALL BE 44" MAX.
NO SCALE
NO SCALE
M A
X
COUNTER OR
LAVATORY
T O
R A
IS
E
D L
T R
F
O R
R M
PLAN: ROLL-IN TYPE ELEVATION: ROLL-IN
ACCESSIBLE SHOWER
NO SCALE
60" MIN
M
IN
M
IN
CLEAR FLOOR SPACE
27" MAX
GRAB BAR
1/2 " MAX TRANSITION
16"-27"
GRAB BAR
SHOWER CONTROLS
FOLDING SEAT
FOLDING SEAT
LAVATORY DIMENSIONS
17" MIN
M
IN
M
A X
M
A X
M
IN
6" MAX
8" MIN
NO SCALE
FRONT APPROACHSIDE APPROACH
DRINKING FOUNTAINS
17" MIN.
19" MAX.
48" MIN.
M
IN
NOT TO EXCEED
FOUNTAIN DEPTH
30" MIN.
M
IN
TO BUBBLER
M
IN
M
A X
HIGH
FOUNTAIN
LOW
FOUNTAIN
17-19"
6" MAX
8" MIN
M
IN
M
A X
M
IN
L O
W F
O U
N T
A
IN
NO SCALE
CL
CL
H.C. LAVATORYH.C. URINAL
H.C. FLOOR MTD. TOILET H.C. WALL MTD. TOILET
LAV FLOOR SPACE
BATHROOM FIXTURES & ACCESSORIES
16"-18"
36" MIN
M
A X
-1
7-9"
SANITARY NAPKIN DISPOSAL
TOILET PAPER DISPENSER
24"-42"6" MAX
12" MAX
-1
7"-9"
12" MAX
24"-42"
42" MIN
TOILET PAPER DISPENSER
SANITARY NAPKIN DISPOSAL
-3
36" MIN
6" MAX
M
A X
M
IN
M
IN
1'-7"
MIN
8" MIN6" MAX
CLEARANCE PROFILE
INSULATE DRAIN
& SUPPLY LINES 4
M A
X T
O
V
IE
W A
B L
E S
U R
F A
C E
MIRROR
PAPER TOWEL DISPENSER
"SOAP DISPENSER 3
M
IN
19" MAX
48" MIN
17"
MIN
"12"
MIN
16"-18"
54" MIN
42" MIN
NO SCALE
M
A X
13 1/2" MIN
M
A X
TO FLUSH CONTROL
-1
18" MIN GRAB BAR PER
ANSI A117.1-2009
39"-41"
18" MIN GRAB BAR PER
ANSI A117.1-2009
CL
ACCESSIBLE
SINGLE TOILET
16"-18"
LAVATORY
60" MIN
NO SCALE
M
IN
SOAP DISPENSER
M
IN
M
IN
C E
N T
E R
M
IX
IN
G
V A
L V
E
S H
O W
E R
S P
R A
Y
H A
N D
L E
SHOWER CONTROLS
S H
O W
E R
H E
A D
R O
U G
H -I
N
SHOWER HEAD
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
GI002
ABA SHEET
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
CODE NOTES
1. DRAWING PURPOSE: RENOVATION
2. FACILITY REVIEWED FOR COMPLIANCE WITH THE FOLLOWING
CODES:
2018 NFPA 101 LIFE SAFETY CODE
2015 INTERNATIONAL BUILDING CODE
2017 NATIONAL ELECTRICAL CODE
2015 INTERNATIONAL MECHANICAL CODE
2015 INTERNATIONAL PLUMBING CODE
2015 INTERNATIONAL FIRE CODE
2010 ARCHITECTURAL BARRIERS ACT (ABA)
3. OWNER:
HARRY S TRUMAN MEMORIAL HOSPITAL
800 HOSPITAL DR
COLUMBIA, MO 65201
PH (573) 814-6000
4. DATE DEVELOPED: SEE DATE IN TITLEBLOCK
6. ARCHITECTS SEAL: SEE STAMP IN TITLEBLOCK
7. FIRE SERVICE: CITY OF COLUMBIA FIRE DEPARTMENT
8. INSPECTION: VISN 15 SAFETY OFFICER
9. OCCUPANCY GROUP TYPE:
5. ARCHITECT:
M+HFG
142 N MOSELY ST STE 300
WICHITA, KS 67212
PH (316) 262-2500
NEW HEALTHCARE (NFPA); I-2 (IBC)
10. CONSTRUCTION TYPE: NFPA TYPE II (222)
11. HEIGHT & AREA LIMITATIONS:
ALLOWABLE AREA: UNLIMITED
HEALTH CARE OCCUPANCY
ALLOWABLE HEIGHT /
STORIES
4 OR MORE
ACTUAL HEIGHT / STORIES 7 OCCUPIABLE STORIES
(UNCHANGED)
BUSINESS OCCUPANCY
ALLOWABLE HEIGHT /
STORIES
N/R
12. MINIMUM CONSTRUCTION REQUIREMENTS (A.8.2.1.2):
CONSTRUCTION
HEALTH CARE OCCUPANCY
BEARING WALLS:
A. EXTERIOR
B. INTERIOR
C. INT/EXT (ROOF ONLY)
TYPE II
(222)
2 HR
2 HR
1 HR
NON-BEARING WALLS:
A. EXTERIOR
B. INTERIOR
0 HR
NON-
COMBUSTIBLE
COLUMNS:
A. SUPPORT FLOORS
B. SUPPORT ROOF ONLY
2 HR
1 HR
BEAMS/GIRDERS/TRUSSES:
A. EXTERIOR:
B. INTERIOR:
2 HR
1 HR
FLOOR CONSTRUCTION: 2 HR
ROOF CONSTRUCTION: 1 HR
NOTE: ENTIRE FACILITY IS FULLY SPRINKLED
13. ACTIVE FIRE SAFETY FEATURES:
(A) AUTOMATIC SUPPRESSION SYSTEMS:
- SPRINKLER SYSTEM (FULLY SPRINKLED)
- EXHAUST HOOD IN KITCHEN - U.L. 300 COMPLIANT
- AUTOMATIC AIR-HANDLING SHUT-DOWN
(B) FIRE ALARM SYSTEM - SIMPLEX, ADDRESSABLE, AUTO DIAL-UP
(C) GENERATOR POWERED EMERGENCY LIGHTING, GENERATOR
POWERED EXIT LIGHTING.
(D) SMOKE DETECTORS AT ALL CORRIDORS, ALL SMOKE DOORS AND
MISC AREAS AS REQ'D (ALSO IN SOME DUCTS)
(E) PORTABLE EXTINGUISHERS
14. WATER SUPPLY: CITY OF COLUMBIA, MO/UMC (SECONDARY)
TYPE II
(000)
0 HR
0 HR
0 HR
0 HR
NON-
COMBUSTIBLE
0 HR
0 HR
0 HR
0 HR
0 HR
0 HR
14. SEWAGE TREATMENT: CITY OF COLUMBIA, MO
14. HANDICAP PROVISIONS: ACCESSIBLE ROUTE, TOILETS,
LAVATORIES, SIGNAGE AND PARKING
17. STORM SEWER: UMC/CITY OF COLUMBIA, MO
LEGEND
BUILDING & LIFE SAFETY REQUIREMENTS
DESCRIPTION
WALL
RATING
NEW
PARTITION KEY NFPA 101-2018
OPENINGS DAMPERS
RATING RFRNC. TYPE RFRNC.
BUILDING SEPARATION:
FIRE BARRIER
2 HR
90 MIN
OCCUPANCY/AREA SEPARATION
FIRE BARRIER
2 HR
90 MIN
HORIZONTAL EXIT (& REFUGE AREA)
FIRE BARRIER
2 HR
90 MIN
VERT. OPG. (EXIT ENCLSR/SHAFT)
FIRE BARRIER
(2 HR = 4 OR MORE STORIES)
(1 HR = LESS THAN 4 STORIES)
(1/2 HR = EXIST. ENCL. IN EXIST BLD'G)
1 HR
2 HR
60 MIN
90 MIN
HAZ./INCIDENTAL USE
FIRE BARRIER
1 HR 45 MIN
HAZ./INCIDENTAL USE
SMOKE PARTITIONS
(SPRINKLERED)
NR-
RESIST
SMK
NR
SELF OR AUTO
CLOSING
SUBDIVIDING SPACES
SMOKE BARRIER (I-2 OCCUPANCY)
20 MIN
1/2
HR
1 HR
SUITE SEPARATION
SMOKE PARTITION
NR
*NR
SELF OR AUTO
CLOSING
EXIT ACCESS CORRIDORS (I-2)
SMOKE PARTITIONS (SPRINKLERED)
NR-
RESIST
SMK
NR
EXIT ACCESS CORRIDORS (B & AHC)
NON-RATED PARTITIONS
NR
NR
1 HR
VERT. OPG. (SHAFT)
FIRE BARRIER 60 MIN
1 HR
2 HR
60 MIN
90 MINEXIT PASSAGEWAY (HORIZ.)
FIRE BARRIER
6.1.14.4.1 18.1.3.5.1 19.1.3.5.1
7.2.4.1.3 (1)
18.1.3.8 /19.1.3.8
18.2.2.5 /19.2.2.5 7.1.3.2.1
18.3.1.1-8 19.3.1.1-8 8.6
8.7.1 18.3.2.1 19.3.2.1
8.4.2 18.2.5.7.1.4 19.2.5.7.1.2
8.4.2 18.3.6.2 19.3.6.2
21.3.6 35.3.6
18.3.1.1 19.3.1.1 8.6
8.2.1.3
7.2.6 18.2.2.7 19.2.2.7
18.3.2.1.2 19.3.2.1.2
8.5 18.3.7.3 19.3.7.3
7.2.1.4.1 7.2.4.3.7 8.3.4 18.2.2.5, 1-4 19.2.2.5, 1-4
8.3.3.2.2 TBL
18.2.2.2 19.2.2.2
7.1.3.2 (9)
8.3.3.2.2 TBL
18.3.2.1.3 19.3.2.1.3
8.3.3.2.2 TBL
8.5.4 18.3.7.8 19.3.7.8
8.3.3.2.2 TBL
18.2.2.2 19.2.2.2
8.3.3.2.2 TBL
8.3.3.2.2 TBL
8.3.3.2.2. TBL
8.7.1.3 8.4.3 18.3.2.1.3 19.3.2.1.3
18.3.6.3.2 19.3.6.3.2 8.4.3
18.3.6.3 19.3.6.3 8.4.3
N/A
FIRE
90 MIN
FIRE
90 MIN
FIRE
90 MIN
NOT
ALLOWED
UNLESS
SERVING
STAIR
ONLY
N/A
VARIES
SMOKE
90 MIN
VARIES
VARIES
NONE
N/A
NOT
ALLOWED
8.3.4.8 9.2.1
8.3.4.8 9.2.1
8.3.4.8 9.2.1 7.2.4.3.5
N/A
8.5.5.3 19.3.7.3(2)
8.6.4.5
N/A
N/A
8.4.4
8.4.4 8.4.6.2
8.4.4.1 8.4.6.2 18.3.6.4.2 19.3.6.4.2
N/A
SYMBOLS
NO. OCC. EXITING
(SMALLER ROOMS)
MAXIMUM OCCUPANCY
AREA
OCC. LOAD
FACTOR
FIRE ALARM CONTROL PANEL
FIRE SYSTEM ANNUNCIATOR ALARM
ANNUNCIATOR PANEL
FACP
FSA
FAA
REQ'D. EXIT WIDTH
NO. OF OCC. EXITING
ACTUAL EXIT
WIDTH
NO. OF OCC./
NO. OF EXITS
1:50
10/1
2"
34"
FEC
FP
PROPERTY LINE
STARTING
LOCATION
TRAVEL DISTANCE
TRAVEL PATH
FE
FIRE EXTINGUISHER CABINET
FIRE PULL STATION
FIRE EXTINGUISHER
NOTES
[A] DAMPERS ARE NOT REQUIRED IN DUCT PENETRATIONS OF
SMOKE BARRIERS WHERE HVAC SYSTEMS ARE FULLY DUCTED
(18.3.7.3x2)
[B] AIR TRANSFER OPENINGS IN SMOKE PARTITIONS SHALL
HAVE DAMPERS (NFPA 8.2.4.4.3) (IBC 710.7)
[C] SMOKE DAMPERS ARE NOT REQUIRED WHERE OPENINGS IN
DUCT ARE LIMITED TO A SINGLE SMOKE COMPARTMENT &
DUCTS ARE MADE OF STEEL (IBC 716.5.5)
[D] TRANSFER GRILLES REGARDLESS OF WHETHER THEY ARE
PROTECTED
ARE NOT ALLOWED IN THESE DOORS OR WALLS (NFPA 18.3.6.4)
TD = XX
633/9
21"
46"
633/9
21"
46"
STAIR #2
STAIR #1
633/9
21.3"
46"
633/9
21.3"
46"
633/9
21"
46"
633/9
21"
46"
633/9
21.3"
46"
633/9
21"
46"
STAIR #6
STAIR #7
STAIR #8
STAIR #3
STAIR #4
STAIR #5
COMPLIANCE NOTE
COMPLIANCE NOTE
PER NFPA
8.2.5.6
STAIR #1 SHALL BE PERMITTED
TO DISCHARGE THROUGH AREA
OF LEVEL OF EXIT DISCHARGE.
STAIR #2 SHALL BE PERMITTED
TO DISCHARGE THROUGH AREA
OF LEVEL OF EXIT DISCHARGE.
COMPLIANCE NOTE
DELAYED EGRESS ALARMED
DOOR
COMPLIANCE NOTE
DELAYED EGRESS / ACCESS
CONTROL DOOR
TD = 100'-0"(TEMP)
T D
T D
T D
T D
TD = 159'-8"
T D
TD = 102'-4"
633/9
21"
46"
STAIR #12
STAFF
LOUNGE
D343
DIALYSIS
D342
SOCIAL
D337
WAD
D339 CHG ROOM
D343B
SHARED
OFFICE
D335
OFFICE
D333
SWAMP #1
D331
SWAMP #4
D329
HOSPITALIST
D328
HSKPG
D326
CORR.
C3C4
SWAMP #3
D330
SWAMP #2
D332
CODER/REVIEW
D334
CORR.
C3D3
CORR.
C3D4
SOILED
D342A
NURSE MGR/
ASST MGR.
A325 NURSE
A328
MEDS
A319
ISO/BAR #1
A301
ISO/BAR #2
A302
ISO/BAR #3
A303
TLT./SHWR
A303A
ANTE
A302B
ANTE
A301B
ANTE
A303B
TLT./SHWR
A301A
TLT./SHWR
A302A
TLT./SHWR
A305A
PAT. RM #5
A305
CLEAN LINEN
A322
NOUR.
A324
SOILED
A320
GEN. STOR.
A326
CORR.
C3A3
MSA
D302
TLT./SHWR
D304A
PAT. RM #4
D304
PAT. RM #6
D306
PAT. RM #8
D308
PAT. RM #10
D310
PAT. RM #12
D312
PAT. RM #7
A307
PAT. RM #9
A309
PAT. RM #11
A311
TLT./SHWR
A307A
TLT./SHWR
A309A
TLT./SHWR
A311A
NURSE
WK/COPY
A333
NURSE
A332
CLEAN
A321 ELEC./SYSTEMS
A330
STRETCHER
D303
EQUIP.
D305
MED. GAS
D307
STRETCHER
D309
NOUR.
A334
MEDS
A335
CLEAN
A336
SOILED
A337
CLEAN LINEN
A336A
TLT.
A338
STAIR #4
A346 BARIATRIC
#13
A313
PAT. RM #14
A314
BARIATRIC
#15
A315
PAT. RM #16
A316
PAT. RM #17
A317
BARIATRIC
#18
A318
ISO/BAR #19
D319
BARIATRIC
#20
D320
PAT. RM #21
D321
PAT. RM #22
D322
PAT. RM #23
D323
PAT. RM #24
D324
CORR.
C3D5
TLT./SHWR
D324A
PT TLT.
D323A
TLT./SHWR
D322A
TLT./SHWR
D321A
TLT./SHWR
D320A
TLT./SHWR
D319A
TLT./SHWR
A318A
TLT./SHWR
A317A
TLT./SHWR
A316A
TLT./SHWR
A315A
TLT./SHWR
A314A
CORR.
C3A6
CORR.
C3A4
TLT./SHWR
D306A
TLT./SHWR
D308A
TLT./SHWR
D310A
TLT./SHWR
D312A
TLT.
D318
CLEAN LINEN
D317A
CLEAN
D317
SOILED
D316
MEDS
D315
NURSE
D314
NOUR.
D313
EQUIP
D311
TLT./SHWR
A313A
NURSE
WK/COPY
A329
COPY
D336
CORR.
C3A2
ELEC
D338
STAIR #5
D325
STAIR #6
D327
STAIR #2
D340
CONSULT RM.
D344
STORAGE
D345
STORAGE
A327
HSKPG
A331
T D
T E
M P
TD = 84'-0"
T D
T D
DIALYSIS
STOR.
D342B
T D
TD = 113'-0"
T D
THIRD FLOOR KEY PLAN
A
B
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
GI003
LIFE SAFETY PLANS
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
1" = 20'-0"
3 - THIRD FLOOR - MEDICAL WARD
N
ABCDEFGGaHJ
2.8
3.7
7.3
8.2
9.1
10.4
Ba
4.6
6.3
1.6
3.2
2.7
8.0
1.9
5.5
1.1
F.1 E.a2 Aa
13.6
S H
A D
E D
A R
E A
N O
T I N
S C
O P
E O
F P
R O
J E
C T
SHADED AREA NOT IN
SCOPE OF PROJECT
PHASE 1.1
PHASE 1.1
PHASE 1.1 ABOVE CEILING:
PLUMBING AND MECHANICAL WORK AS PER MEP DRAWINGS. ANY
WORK THAT DISRUPTS NORMAL OPERATIONS IN THESE AREAS SHALL
BE COMPLETED AFTER NORMAL BUSINESS HOURS. ALL CEILINGS MUST
BE REINSTALLED DAILY TO MAINTAIN SPRIKLER COVERAGE.
PHASE 1.1 ABOVE CEILING:
PLUMBING AND MECHANICAL WORK AS PER MEP DRAWINGS. ANY
WORK THAT DISRUPTS NORMAL OPERATIONS IN THESE AREAS SHALL
BE COMPLETED AFTER NORMAL BUSINESS HOURS. ALL CEILINGS MUST
BE REINSTALLED DAILY TO MAINTAIN SPRIKLER COVERAGE.
PHASE 1.1 ABOVE CEILING:
PLUMBING AND MECHANICAL WORK AS PER MEP DRAWINGS. ANY
WORK THAT DISRUPTS NORMAL OPERATIONS IN THESE AREAS SHALL
BE COMPLETED AFTER NORMAL BUSINESS HOURS. (NOTE SLEEP LAB
HOURS ABOVE) ALL CEILINGS MUST
BE REINSTALLED DAILY TO MAINTAIN SPRIKLER COVERAGE.
SLEEP LAB NORMAL WORKING HOURS:
MON-FRI 7P-7A & SAT & SUN 7P-7A
COORDINATE AFTER HOURS WORK
SCHEDULE W/COR
PHASE 1 (CONSTRUCT)
PHASE 2.1 (REMOVAL)
TEMPORARY ROOF ACCESS,
DO NOT BLOCK BASEMENT
LEVEL DOORS
ABCDEFG
2.8
3.7
7.3
8.2
9.1
10.4
4.5
Ba
4.6
6.3
8.0
1.9
5.5
1.1
F.1 E.a2 Aa
THIRD FLOOR ROOF
FIRST FLOOR ROOF BELOW
NEW RTU, REF MECHANICAL
PHASE 1 (CONSTRUCT)
PHASE 2.1 (REMOVAL)
TEMPORARY ROOF ACCESS,
DO NOT BLOCK BASEMENT
LEVEL DOORS
FIRST FLOOR ROOF BELOW
PHASE 2.1
PHASE 2
PHASING LEGEND
PHASE 1: THIRD FLOOR - DEMOLITION OF EXISTING AREA INCLUDING THIRD
FLOOR BALCONY, CONSTRUCTION OF TEMPORARY ACCESS TO THIRD
FLOOR ROOF, CONSTRUCTION OF NEW ADMINISTRATIVE AREA INCLUDING
NEW DIALYSIS SUITE WITH ALL NEW MEP SYSTEMS AS NEEDED
PHASE 2: THIRD FLOOR - DEMOLITION OF EXISTING CLC AREA,
CONSTRUCTION OF NEW PATIENT PRIVACY SUITE WITH ALL NEW MEP
SYSTEMS AS NEEDED.
PHASE 1.1: SECOND FLOOR CEILING - SPECIAL COORDINATION OF MEP
WORK RELATED TO PHASE 1, SHALL BE ACCOMPLISHED AFTER HOURS,
NIGHTS & WEEKENDS. SEE DRAWING FOR SLEEP LAB HOURS AND
COORDINATE WORK TIMES WITH COR
NOTES:
1. TEMPORARY CONSTRUCTION BARRIERS SHALL BE MIN. 1 HOUR RATED ASSEMBLY.
2. DOORS IN TEMPORARY CONSTRUCTION BARRIERS TO BE 45 MIN. RATED
3. ALL CEILINGS DISTURBED DURING OVER CEILING WORK SHALL BE RE-INSTALLED
PRIOR TO END OF EACH WORK SHIFT.
4. ALL OPENINGS THROUGH CONCRETE FLOORS (RATED), MUST BE FIRSTOPPED OR
INFILLLED PRIOR TO END OF EACH WORK SHIFT.
PHASE 2.1: REMOVAL/SALVAGE OF FOURTH FLOOR WINDOW FOR
CONSTRUCTION OF NEW THIRD FLOOR ROOF ACCESS. REMOVAL OF
TEMPORARY ROOF ACCESS.
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
GI004
PHASING PLAN - 2ND & 4TH FLOORS
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
1/16" = 1'-0"
PHASING PLAN - 2ND FLOOR
1/16" = 1'-0"
PHASING PLAN - 4TH FLOOR
N
N
2.8
3.7
7.3
8.2
9.1
10.4
BaH.5
4.6
6.3
8.0
1.9
5.5
1.1
F.1 E.a2 Aa
13.6
SHADED AREA NOT IN
SCOPE OF PROJECT
S H
A D
E D
A R
E A
N O
T I N
S C
O P
E O
F P
R O
J E
C T
SHADED AREA NOT IN
SCOPE OF PROJECT
IT BELOW
S P
L
IT
L O
C K
E R
S
T T
L
PHASE 1
PHASE 2
PHASE 1 (CONSTRUCT)
PHASE 2.1 (REMOVAL)
TEMPORARY ROOF ACCESS,
DO NOT BLOCK BASEMENT
LEVEL DOORS
CONSTRUCT TEMPORARY
CONSTRUCTION BOUNDARY
AT BEGINNING OF PHASE 2
REMOVE TEMPORARY CONSTRUCTION BOUNDARY
AT END OF PHASE 2, REPLACE DOOR AND
PROVIDE NEW FINISHES PER PLANS
CONSTRUCT TEMPORARY
CONSTRUCTION BOUNDARY
AT BEGINNING OF PHASE 1
CONSTRUCT TEMPORARY
CONSTRUCTION BOUNDARY
AT BEGINNING OF PHASE 1
CONSTRUCT TEMPORARY
CONSTRUCTION BOUNDARY
AT BEGINNING OF PHASE 1
CONSTRUCT TEMPORARY
CONSTRUCTION BOUNDARY
AT BEGINNING OF PHASE 1
CONSTRUCT TEMPORARY
CONSTRUCTION BOUNDARY
AT BEGINNING OF PHASE 2
PHASING LEGEND
PHASE 1: THIRD FLOOR - DEMOLITION OF EXISTING AREA INCLUDING THIRD
FLOOR BALCONY, CONSTRUCTION OF TEMPORARY ACCESS TO THIRD
FLOOR ROOF, CONSTRUCTION OF NEW ADMINISTRATIVE AREA INCLUDING
NEW DIALYSIS SUITE WITH ALL NEW MEP SYSTEMS AS NEEDED
PHASE 2: THIRD FLOOR - DEMOLITION OF EXISTING CLC AREA,
CONSTRUCTION OF NEW PATIENT PRIVACY SUITE WITH ALL NEW MEP
SYSTEMS AS NEEDED.
PHASE 1.1: SECOND FLOOR CEILING - SPECIAL COORDINATION OF MEP
WORK RELATED TO PHASE 1, SHALL BE ACCOMPLISHED AFTER HOURS,
NIGHTS & WEEKENDS. SEE DRAWING FOR SLEEP LAB HOURS AND
COORDINATE WORK TIMES WITH COR
NOTES:
1. TEMPORARY CONSTRUCTION BARRIERS SHALL BE MIN. 1 HOUR RATED ASSEMBLY.
2. DOORS IN TEMPORARY CONSTRUCTION BARRIERS TO BE 45 MIN. RATED
3. ALL CEILINGS DISTURBED DURING OVER CEILING WORK SHALL BE RE-INSTALLED
PRIOR TO END OF EACH WORK SHIFT.
4. ALL OPENINGS THROUGH CONCRETE FLOORS (RATED), MUST BE FIRSTOPPED OR
INFILLLED PRIOR TO END OF EACH WORK SHIFT.
PHASE 2.1: REMOVAL/SALVAGE OF FOURTH FLOOR WINDOW FOR
CONSTRUCTION OF NEW THIRD FLOOR ROOF ACCESS. REMOVAL OF
TEMPORARY ROOF ACCESS.
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
GI005
PHASING PLAN - 3RD FLOOR
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
1/16" = 1'-0"
PHASING PLAN - 3RD FLOOR
N
ASBESTOS CONTAINING
FLOORING MASTIC
DEMO LEGEND
*ASBESTOS CONTAINING
PIPING WRAPS
2ND FLOOR: 0 S.F.
3RD FLOOR: 8170 S.F.
2ND FLOOR: 0 L.F.
3RD FLOOR: 2958 L.F.
APPROXIMATE QUANTITIES
*ABATE ASBESTOS AND REINSULATE ALL EXISTING INDUCTION AND REHEAT MAIN
LINES THAT ARE TO REMAIN. REF. MECHANICAL PLANS FOR MORE INFORMATION
GENERAL HAZARDOUS MATERIALS NOTES
A. REMOVE ALL ASBESTOS PIPE FITTING INSULATION WITHIN THE ASBESTOS ABATEMENT WORK SPACE, ABOVE AND BELOW CEILINGS AND IN THOSE CHASES SCHEDULED FOR DEMOLITION. REMOVE ALL DEBRIS FOUND IN THE WORK AREA. USE TRADITIONAL ASBESTOS ABATEMENT METHODS IN THOSE AREAS WHERE INSULATION MAY BE DAMAGED AND SIGNIFICANT PORTIONS OF DEBRIS MAY EXIST. CHASE WALLS SHALL BE REMOVED USING TRADITIONAL ASBESTOS ABATEMENT TO PRECLUDE ANY POSSIBLE RELEASE OF MATERIAL INTO THE
AREA DUE TO DEMOLITION ACTIVITIES.
B. REMOVE ALL FLOOR TILE AND FLOOR TILE MASTIC WITHIN THE ASBESTOS ABATEMENT WORK AREA.
C. REMOVE AND REPLACE WITH NEW ANY PLUMBING/MECHANICAL SYSTEM THAT IS TO REMAIN IN USE. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS. PLUMBING/MECHANICAL SYSTEMS TO BE PERMANENTLY REMOVED, MAY BE CUT AND WRAPPED AND REMOVED IN SECTIONS WITH THE INSULATION STILL ATTACHED.
D. ENCAPSULATE THE EXPOSED ENDS OF ANY PIPE INSULATION THAT ARE NOT REMOVED AT ADJOINING FLOOR
LEVELS.
E. SEE SPECIFICATIONS SECTIONS 028211 & 028213-19 FOR ASBESTOS ABATEMENT AND ASBESTOS SURVEY.
FLOORING MASTIC
APPROX. 560 S.F.
FLOORING MASTIC
APPROX. 160 S.F.
FLOORING MASTIC
APPROX. 700 S.F.
FLOORING MASTIC
APPROX. 300 S.F.
FLOORING MASTIC
APPROX. 700 S.F.
FLOORING MASTIC
APPROX. 400 S.F.
FLOORING MASTIC
APPROX. 1000 S.F.
FLOORING MASTIC
APPROX. 1400 S.F.
FLOORING MASTIC
APPROX. 1400 S.F.
FLOORING MASTIC
APPROX. 1000 S.F.
FLOORING MASTIC
APPROX. 150 S.F.
FLOORING MASTIC
APPROX. 260 S.F.
FLOORING MASTIC
APPROX. 140 S.F.
18' - 5"
C357
D320
D321
D322
D323
D324
D325
D326
D327
D328
D329
D301A
D316
D353 D353A
D332D
D332A
D332B
D333
D333A D333B D334 D335 D336
D337 D338
D339 D341 D342
D343
D344 D345
D346
D347
D348
D349 D350
D351
A335 A347
A316
A358
A317
A357
A319
A356
A321
A353A354
A321A
A325
A352 A351 A350
A332 A348
A328 A331
A337 A338
A339
A340
A341
A342
A343
A344 A345
A346
A330
A329A327A326
A323A322
A318
A318A
A320
B344
B318
A313
A314
A306A
D330D331
C3D4
D316C
C3D4
C3A6
C3A5
C3D5
C3A4
D352
D330A
D301B
D301
C3C7
#3 #2 #1
C3D1
#4
C3A2
C3D3
C357A
C356A
C343
C338
C359
C341
C360A
C345
C360
C346
C356
C339
C358
C340
D316A
C358C
#6
C3A4
C358A
A312
A300
C3A3
THIRD FLOOR KEY PLAN
A
B
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
HA101
HAZARDOUS MATERIAL PLAN
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
1/16" = 1'-0"
3RD FLOOR - HAZARDOUS MATERIALS
N
CDEF
7.3
8.2
9.1
10.4
8.0
F.1 E.a2
FIRST FLOOR
ROOF
AD101
AD101
2.14
2.14
AD101
2.13
THIRD FLOOR
PATIO ABOVE
AD101
AD101
2.12
2.13
2.132.13
2.13
2.13
GENERAL DEMOLITION NOTES
A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING. THE
CONTRACTOR IS RESPONSIBLE FOR INFORMING THE ARCHITECT OF ANY CONDITIONS THAT
DIFFER FROM THE INFORMATION INDICATED IN THE DRAWINGS.
B. PROTECT ALL EXISTING BUILDING COMPONENTS WHICH ARE TO REMAIN. REPAIR ANY
DAMAGED AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.
C. VERIFY EXTENT OF DEMOLITION WORK WITH INFORMATION SHOWN IN THE DRAWINGS AND
WORK THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE THE INTENDED WORK.
D. ALL WORK SHALL COMPLY WITH REQUIRED LOCAL CODES. CONTRACTOR IS RESPONSIBLE
FOR OBTAINING REQUIRED PERMITS AND INSPECTIONS FOR ALL WORK ASSOCIATED WITH
THIS CONTRACT.
E. CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH
SURROUNDING EXISTING FINISHES NOT DISTURBED.
F. TYPES OF FLOOR, WALL, AND CEILING FINISHES INDICATED FOR REMOVAL BY DEMOLITION
NOTES ARE FOR GENERAL INFORMATION ONLY FROM INFORMATION OBTAINED FROM
EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY MATERIAL TYPES
ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS BID.
G. ALL APPLIANCES, FURNITURE, AND EQUIPMENT TO REMAIN THE PROPERTY OF THE
OWNER - CONTRACTOR TO COORDINATE REMOVAL, RELOCATION AND STORAGE OF
EQUIPMENT FROM DEMO AREAS WITH OWNER.
H. MISCELLANEOUS FLOOR PENETRATIONS AND DEMO FOR NEW MECHANICAL AND
ELECTRICAL WORK SHALL BE COORDINATED FROM ARCHITECTURAL, MECHANICAL, AND
ELECTRICAL PLANS.
I. REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DEMO PLANS FOR DEMOLITION,
SALVAGE AND RE-USE OF EXISTING ITEMS.
J. PATCH FLOOR AT REMOVED WALLS AND CASEWORK, PREPARE FLOOR TO RECEIVE NEW
FLOORING AS REQUIRED.
K. ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES TO RECEIVE INFILL PER
STRUCTURAL DETAIL.
L. REMOVE ALL STAINLESS STEEL CORNER GUARDS CAREFULLY AND GIVE TO OWNER.
M. ELEMENTS INDICATED WITH A DASHED LINE ARE TO BE DEMOLISHED AND DISPOSED OF AS
A PART OF THIS PROJECT, UNLESS NOTED OTHERWISE.
N. IN EXISTING AREAS, RENOVATION AND DEMOLITION WORK SHALL BE ACCOMPLISHED WITH
MINIMAL DISRUPTION TO OPERATIONS. IF REQUIRED, THE OWNER RESERVES THE RIGHT TO
TEMPORARILY STOP WORK OF SPECIFIC CONSTRUCTION OPERATIONS SHOULD THE
OWNER IDENTIFY AN EMERGENCY OR DANGER EXISTS TO THE WELFARE OF THE
OCCUPANTS ON ACCOUNT OF SUCH WORK OR OPERATIONS.
O. CONTRACTOR SHALL REMOVE AND DISPOSE OF IN A LEGAL MANNER ALL MATERIAL NOT
SCHEDULED FOR REUSE UNDER THIS PROJECT .
P. IN ALL WALLS AND CEILINGS THAT ARE TO BE REMOVED THE CONTRACTOR SHALL BE
RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAPPING ELECTRICAL,
PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT ARE NOT SCHEDULED FOR
REUSE. CONTRACTOR SHALL REROUTE AND CONTINUE ANY SYSTEM THAT MUST BE
RETAINED FOR NEW CONSTRUCTION. CONTRACTOR SHALL REROUTE AND KEEP
OPERATIONAL ALL SYSTEMS SERVING SPACES IN THE SURROUNDING AREAS TO THE
PROJECT.
Q. ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT ARE TO BE REMOVED SHALL BE
DISCONNECTED AT SOURCE AND REMOVED BACK TO PANEL.
R. ALL PIPING GAS, WATER SUPPLY, VENT, DRAIN LINES, ETC. SUPPLYING EQUIPMENT THAT
ARE TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED ABOVE CEILING
OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AS NECESSARY, TO BE BEHIND NEW
CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING.)
S. ALL MED GASES AND PLUMBING TO BE REMOVED AT WALLS SCHEDULED FOR DEMOLITION.
T. REMOVE ALL PLUMBING FIXTURES AND EQUIPMENT WITHIN ROOMS SCHEDULED TO BE
DEMOLISHED. SEE MEP PIPING DRAWINGS.
U. RETURN ALL SIGNAGE AFFECTED BY CONSTRUCTION TO OWNER.
2ND LEVEL
13' - 9 1/4"
3RD LEVEL
26' - 5 1/4"
4TH LEVEL
39' - 1 1/4"
FIFTH FLOOR
51' - 9 1/4"
SIXTH FLOOR
64' - 5 1/4"
PENTHOUSE
77' - 1 1/4"
77.38.2
8.0
2.10
2.142.11
2.10
2ND LEVEL
13' - 9 1/4"
3RD LEVEL
26' - 5 1/4"
4TH LEVEL
39' - 1 1/4"
DEF E.a2
2.10
2.112.11
2.15
AE301
E
EXISTING ROOF STRUCTURE
AND ROOF MEMBRANE
REMOVE EXISTING CONCRETE
CURB AND STEEL POST.
REMOVE STEEL POST ANCHORING
SYSTEM DOWN TO CONCRETE ROOF
SLAB. GRIND ANY ANCHORS FLUSH
WITH SLAB AND PREPARE SURFACE
FOR NEW ROOF MEMBRANE.
REMOVE EXISTING ROOF MEMBRANE
ASE REQUIRED TO DEMO CONCRETE
CURB AND POST ANCHORS.
REMOVE EXISTING ROOF MEMBRANE
ASE REQUIRED TO DEMO CONCRETE
CURB AND POST ANCHORS.
E
EXISTING ROOF STRUCTURE
AND ROOF MEMBRANE
PREP EXISTING SURFACE FOR NEW
ROOF MEMBRANE
NEW ROOF MEMBRANE, OVERLAP
EXISTING MIN 6" ALL DIRECTIONS.
MIN
6"
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AD101
DEMOLITION - PATIO
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
1/8" = 1'-0"
DEMOLITION PLAN - 1ST FLOOR ROOF
1/8" = 1'-0"
DEMOLITION PLAN - 2ND FLOOR CEILING - PATIO
N
N
KEYNOTES
KEY VALUE KEYNOTE TEXT
2.10 REMOVE BALCONY ROOF SYSTEM & ROOF SUPPORTS INCLUDING ANGLE IRONS
ATTACHED TO BRICK, REF. STRUCT. DEMO PLANS FOR MORE INFORMATION
2.11 REMOVE METAL RAILING AND BALCONY FLOOR, REF. STRUCT. DEMO PLANS FOR
MORE INFORMATION
2.12 REROUTE ROOF TOP MECHANICAL UNIT PIPING/POWER FROM UNDERSIDE OF
BALCONY TO ROOF MOUNTED SUPPORTS & RECONNECT ALL POWER AND PIPING
LINES. COORDINATE ANY MECHANICAL UNIT SHUT DOWN WITH COR
2.13 REMOVE BALCONY FRAMING INCLUDING BRICK AS REQUIRED TO REMOVE BEAMS
AND KNIFE BLADES FROM COLUMNS. PATCH SHEATHING AND MOISTURE BARRIER
WITH LIKE CONSTRUCTION AND TOOTH-IN MATCHING BRICK
2.14 REMOVE ROOF MEMBRANE AS REQUIRED TO REMOVE BALCONY STEEL COLUMNS
AND CONCRETE CURBS TO DECK. REPAIR ROOF STRUCTURE WITH LIKE
CONSTRUCTION AND PATCH ROOF MEMBRANE, REF DETAILS
2.15 REMOVE BRICK AS REQUIRED TO DEMO DOOR. TOOTH-IN & REPAIR BRICK AS
REQUIRED FOR NEW WINDOW RO, NEW BRICK TO MATCH EXISTING
1/8" = 1'-0"
PARTIAL EAST ELEVATION @ DEMOLISHED PATIO
1/8" = 1'-0"
PARTIAL SOUTH ELEVATION @ DEMOLISHED PATIO
3/4" = 1'-0"
DEMO @ PATIO COLUMNS
3/4" = 1'-0"
DETAIL @ PATIO ROOF MEMBRANE REPAIR
SCOPE OF WORK LEGEND
SHADED AREA NOT IN SCOPE OF WORK
DIAGONAL HATCH AREA INDICATES WORK IN EXISTING SPACES NOT VACATED
AND THAT NEED TO REMAIN OPERATIONAL. COORDINATION WITH COR IS
NEEDED TO ACCOMPLISH WORK AFTER HOURS, NIGHTS AND WEEKENDS.
GENERAL DEMOLITION NOTES
A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING. THE
CONTRACTOR IS RESPONSIBLE FOR INFORMING THE ARCHITECT OF ANY CONDITIONS THAT
DIFFER FROM THE INFORMATION INDICATED IN THE DRAWINGS.
B. PROTECT ALL EXISTING BUILDING COMPONENTS WHICH ARE TO REMAIN. REPAIR ANY
DAMAGED AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.
C. VERIFY EXTENT OF DEMOLITION WORK WITH INFORMATION SHOWN IN THE DRAWINGS AND
WORK THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE THE INTENDED WORK.
D. ALL WORK SHALL COMPLY WITH REQUIRED LOCAL CODES. CONTRACTOR IS RESPONSIBLE
FOR OBTAINING REQUIRED PERMITS AND INSPECTIONS FOR ALL WORK ASSOCIATED WITH
THIS CONTRACT.
E. CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH
SURROUNDING EXISTING FINISHES NOT DISTURBED.
F. TYPES OF FLOOR, WALL, AND CEILING FINISHES INDICATED FOR REMOVAL BY DEMOLITION
NOTES ARE FOR GENERAL INFORMATION ONLY FROM INFORMATION OBTAINED FROM
EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY MATERIAL TYPES
ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS BID.
G. ALL APPLIANCES, FURNITURE, AND EQUIPMENT TO REMAIN THE PROPERTY OF THE
OWNER - CONTRACTOR TO COORDINATE REMOVAL, RELOCATION AND STORAGE OF
EQUIPMENT FROM DEMO AREAS WITH OWNER.
H. MISCELLANEOUS FLOOR PENETRATIONS AND DEMO FOR NEW MECHANICAL AND
ELECTRICAL WORK SHALL BE COORDINATED FROM ARCHITECTURAL, MECHANICAL, AND
ELECTRICAL PLANS.
I. REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DEMO PLANS FOR DEMOLITION,
SALVAGE AND RE-USE OF EXISTING ITEMS.
J. PATCH FLOOR AT REMOVED WALLS AND CASEWORK, PREPARE FLOOR TO RECEIVE NEW
FLOORING AS REQUIRED.
K. ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES TO RECEIVE INFILL PER
STRUCTURAL DETAIL.
L. REMOVE ALL STAINLESS STEEL CORNER GUARDS CAREFULLY AND GIVE TO OWNER.
M. ELEMENTS INDICATED WITH A DASHED LINE ARE TO BE DEMOLISHED AND DISPOSED OF AS
A PART OF THIS PROJECT, UNLESS NOTED OTHERWISE.
N. IN EXISTING AREAS, RENOVATION AND DEMOLITION WORK SHALL BE ACCOMPLISHED WITH
MINIMAL DISRUPTION TO OPERATIONS. IF REQUIRED, THE OWNER RESERVES THE RIGHT TO
TEMPORARILY STOP WORK OF SPECIFIC CONSTRUCTION OPERATIONS SHOULD THE
OWNER IDENTIFY AN EMERGENCY OR DANGER EXISTS TO THE WELFARE OF THE
OCCUPANTS ON ACCOUNT OF SUCH WORK OR OPERATIONS.
O. CONTRACTOR SHALL REMOVE AND DISPOSE OF IN A LEGAL MANNER ALL MATERIAL NOT
SCHEDULED FOR REUSE UNDER THIS PROJECT .
P. IN ALL WALLS AND CEILINGS THAT ARE TO BE REMOVED THE CONTRACTOR SHALL BE
RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAPPING ELECTRICAL,
PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT ARE NOT SCHEDULED FOR
REUSE. CONTRACTOR SHALL REROUTE AND CONTINUE ANY SYSTEM THAT MUST BE
RETAINED FOR NEW CONSTRUCTION. CONTRACTOR SHALL REROUTE AND KEEP
OPERATIONAL ALL SYSTEMS SERVING SPACES IN THE SURROUNDING AREAS TO THE
PROJECT.
Q. ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT ARE TO BE REMOVED SHALL BE
DISCONNECTED AT SOURCE AND REMOVED BACK TO PANEL.
R. ALL PIPING GAS, WATER SUPPLY, VENT, DRAIN LINES, ETC. SUPPLYING EQUIPMENT THAT
ARE TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED ABOVE CEILING
OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AS NECESSARY, TO BE BEHIND NEW
CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING.)
S. ALL MED GASES AND PLUMBING TO BE REMOVED AT WALLS SCHEDULED FOR DEMOLITION.
T. REMOVE ALL PLUMBING FIXTURES AND EQUIPMENT WITHIN ROOMS SCHEDULED TO BE
DEMOLISHED. SEE MEP PIPING DRAWINGS.
U. RETURN ALL SIGNAGE AFFECTED BY CONSTRUCTION TO OWNER.
ABCDEFGGaHJ
2.8
3.7
7.3
8.2
9.1
10.4
Ba
6.2
5.4
6.7
4.6
6.3
1.6
3.2
2.7
8.0
1.9
5.5
1.1
F.1 E.a2 Aa
13.6
4.4
S H
A D
E D
A R
E A
N O
T I N
S C
O P
E O
F P
R O
J E
C T
SHADED AREA NOT IN
SCOPE OF PROJECT
2.17
2.17
2.17 2.17 2.17
2.17
2.17 2.17
2.17
2.18
2.17 2.17 2.17
A235
A222
A222A
A223
A225
A227
A228
A229
A230 A232
A251A
A246
A249A249A
STAIR #4
A244
A244A
A241
A251
A252A
A252
D229
D231A D229A
D232
D230
D228
D227D227A
D233
D234
D236
D240
STAIR #5
D241
D239
D237
D235A
D235
D231
A233
A236A234
A246A
A253A254A255A256A257A258
D222 D223 D224
D226 D221
C2A6BC2A6A
A262
A259A260
A220
A221
A214
A204
A205A206
A204A
D205
D205A
D200A
D205B
D205C
D212D
D212E
D212F
C235A C235B
C235
C236
C237
C238
C239
C240
C241
C242
C243
C237A
D218
D218A
D218BD218C
STAIR #6
D216
D210
D214 D215
D208
D209
D220
D219B
D204 D219C D219D
D219F
D219HD219G
D219E
STAIR #2
D219A
D219
D203
D207BD207C
A216A215
A213
A219
A211
A213
STAIR #1
C2A1
C2A5
C2A4
A200
D201A
D206A
D201
A200A
C2A3
C2A6
C2D6
C2E8
C2D1
C2D3
D225
#3 #1
C2A2
#4
#5
D217
D218
D213F
D213E
D213G
D213D
D213B
C2D4
D213A
D213C
D213L
DD213J
D213K
#6
D221A
D209A
#2
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AD102
DEMOLITION PLAN - 2ND FLOOR -
ABOVE CEILING
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
N
1/16" = 1'-0"
DEMOLITION PLAN - 2ND FLOOR - ABOVE CEILING
KEYNOTES
KEY VALUE KEYNOTE TEXT
2.17 TEMPORARILY REMOVE EXISTING CEILING GRID AND TILES AS NECESSARY FOR
DEMO/INSTALL OF MECHANICAL(SEE MECH PLANS); REINSTALL GRID AND TILE AND
REPARE ANY DAMAGES THAT OCCURED DURING CONSTRUCTION.
2.18 REMOVE EXISTING GYP CEILING AS NECESSARY FOR DEMO/INSTALL OF
MECHANICAL(SEE MECH PLANS); REPLACE, PATCH AND PAINT CEILING WHERE
AFFFECTED BY CONSTRUCTION. ADD ACCESS PANELS AS REQUIRED TO SERVICE
NEW MECHANICAL.
2.8
3.7
7.3
8.2
9.1
10.4
BaH.5
4.6
6.3
8.0
1.9
5.5
1.1
F.1 E.a2 Aa
13.6
SHADED AREA NOT IN
SCOPE OF PROJECT
S H
A D
E D
A R
E A
N O
T I N
S C
O P
E O
F P
R O
J E
C T
SHADED AREA NOT IN
SCOPE OF PROJECT
SHADED AREA NOT IN
SCOPE OF PROJECT
ISO/BAR #1
A301 ISO/BAR #2
A302
ISO/BAR #3
A303
MEDS
A319
NOUR.
A324
NURSE MGR/
ASST MGR.
A325
PAT. RM #24
D324
PAT. RM #23
D323
PAT. RM #22
D322
PAT. RM #21
D321
BARIATRIC
#20
D320
ISO/BAR #19
D319
BARIATRIC
#18
A318
PAT. RM #17
A317
PAT. RM #16
A316
BARIATRIC
#15
A315
PAT. RM #14
A314
BARIATRIC
#13
A313
GEN. STOR.
A326
DIALYSIS
D342
MEDS
A335
SOILED
A337
CLEAN LINEN
A336A
NURSE
D314
MEDS
D315
SOILED
D316
CLEAN
D317
CLEAN LINEN
D317A
ANTE
D319B
NURSE
A328
ANTE
A301B
ANTE
A302B
ANTE
A303B
CLEAN
A336
HSKPG
D326
NURSE
WK/COPY
A329
TLT.
D318
TLT.
A338
STAFF
LOUNGE
D343
CHG ROOM
D343B
L O
C K
E R
D A
WAD
D339
SOCIAL
D337
SHARED
OFFICE
D335
OFFICE
D333
SWAMP #1
D331
SWAMP #4
D329
HOSPITALIST
D328
SWAMP #3
D330
SWAMP #2
D332
CODER/REVIEW
D334
COPY
D336
ELEC
D338
NURSE
A332
PAT. RM #11
A311
PAT. RM #9
A309
PAT. RM #7
A307
PAT. RM #5
A305
CLEAN LINEN
A322SOILED
A320
ELEC./SYSTEMS
A330
CLEAN
A321
MED. GAS
D307
EQUIP.
D305
STRETCHER
D303
STRETCHER
D309
NURSE
WK/COPY
A333
PAT. RM #10
D310
PAT. RM #8
D308
PAT. RM #6
D306
PAT. RM #4
D304
E Q
U
IP
D
NOUR.
D313
MSA
D302
NOUR.
A334
SOILED
D342A
A301A
A302A
A303A
A305A A307A A309A A311A
STAIR #4
A346 A313A
A314A
A315A
A316A
A317A
A318A
D319A
D320A
STAIR #5
D325
STAIR #6
D327
STAIR #2
D340
TLT.
D341
D321A
D322A
D323A
D324A
CORR.
C3A2
CORR.
C3A3
CORR.
C3D4
CORR.
C3D3
CORR.
C3C4
CORR.
C3A4
CORR.
C3A6
CORR.
C3D5
D304A D306A D308A D310A D312A
STORAGE
D345
STORAGE
A327
PAT. RM #12
D312
HSKPG
A331
CONSULT RM.
D344
NEW PIPING/PENETRATION
LOCATION
DEMO LEGEND - FLOOR PENETRATIONS
COLUMN STRIP
EXISTING PIPING TO BE
REMOVED AND
PENETRATION INFILLED
INTERSECTING COLUMN
STRIPS
MIDDLE STRIP
OR
- REF. MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION
- REF. STRUCTURAL DRAWINGS FOR EXISTING OPENING INFILL AND NEW OPENING CFRP PLACEMENT
DETAILS
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .