This file summary describes a federal contract solicitation for relocating a medical ward. The solicitation number 36c25522R0024 was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15 to procure signed drawings and specifications for relocating a medical ward at a veterans facility to improve patient privacy. The solicitation documents include specifications, drawings, and response requirements to relocate the medical ward identified as project number 589A4-21-100 by the proposal due date to improve privacy for patients.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8' - 10" 8' - 10"
8' - 10"
7'
0"
7'
0" 8' - 10"
8' - 10" 8' - 10"
8' - 10"
8' - 10"
8' - 10"
9' - 0"
7'
0"
7'
0" 7'
0"
9' - 0"
7'
0"
8' - 10"
8' - 10"
8' - 10" 8' - 10"
8' - 10"
8' - 10"
8' - 10"
7'
3"
7' - 6"
7'
0"
7' - 2" 7' - 2" 9' - 0" 7' - 2"
8' - 4"
7' - 6"
7' - 6"
8' - 4"
8' - 10"
8' - 10"
8' - 10"
8' - 10" 8' - 10"
8' - 10"
8' - 10"
8' - 10"
7' - 2"
7' - 2"
9' - 0"
9' - 0"
7' - 0"
9' - 0"
9' - 0"
7' - 2"
7'
0"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
9' - 0"
9' - 0"
7' - 0"
8' - 6"
9' - 0"
9' - 0"
7' - 0"
8' - 4"
8' - 4"
A313
A314
A315
A316
A317
A318
D319
D320
D321
D314
C3D5
C3A4
D320A
D319B
D319A
A318A
A317A
A316A
A315A
A314A
A313A
A338
A336A
A337
A336
A335
A334
A332
A333
A321
A330
A322
A305A
A305 A307 A309
A307A A309A A311A
A311
D309
D307
D305D303
D312
D312A
D310A
D310
D308
D308AD306A
D306 D304
D304A
D302
A328
A329
A324
A320
A319
A325
D342A
D342
C3D4
D343
A326
C3A2
A301A
A301B A302B
A303A
A303B
A303
A302 A301
A302A
C3A3
A346
C3A6
D321A
8' - 4"
9' - 0"
9' - 0"
7' - 6"
8' - 4"
8' - 4"
8' - 4"
D345
7' - 0"
8' - 10"
10.21
10.21
10.21
D
D313
8' - 10"
10.21 10.21
10.21
10.21
10.21
9' - 5 3/4"
8' - 10"
9' - 5 3/4"
8' - 10"
9' - 5 3/4"
8' - 10"
9' - 5 3/4"
8' - 10"
9' - 5 3/4"
7' - 3"
7' - 11"
9' - 0"
9' - 5 3/4"
9' - 5 3/4"
8' - 11"
3'-6"
7' - 11"
1'-4" 2'-1"
/8
/8
/4
9' - 5 3/4" 9' - 5 3/4"
9' - 5 3/4" 9' - 5 3/4"
9' - 5 3/4"
8' - 10" 8' - 9"
8' - 9" 8' - 9" 8' - 9"
8' - 9" 8' - 9" 8' - 10"
9' - 5 3/4" 9' - 5 3/4" 9' - 5 3/4" 9' - 5 3/4"
9' - 0"
8' - 9"
8' - 10"
8' - 9"
8' - 9"
8' - 9"
8' - 9"
8' - 9"
8' - 10"
8' - 9"
8' - 10"
9' - 5 3/4"
9' - 5 3/4"
9' - 5 3/4"
9' - 5 3/4"
9' - 5 3/4"
9' - 5 3/4"
9' - 5 3/4"
9' - 5 3/4"
9' - 5 3/4"
9' - 5 3/4"
3'-6"
3'-6"
3'-6"
3'-6"
3'-6"
3'-6"
3'-6"
3'-6"
3'-6"
3'-6"
3'-6"
AE601
AE601
________ 2
AE601
AE601
AE601
AE601
AE601
AE601
AE601
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE601
AE601
AE501
7' - 11"
2'-1"
1'-4"
8' - 6"
7' - 11"
7' - 6"
A327
7' - 4"
7' - 4"
7' - 4" 7' - 4"
7' - 4"
7' - 4" 7' - 4"
7' - 4"
7' - 4"
7' - 4"
7' - 4"
7' - 4" 7' - 4"
10.21
10.21
10.21
10.21
10.21
10.21
10.21
8' - 10" 8' - 10"
D322A D322
7' - 0"
7' - 0"
2'-2"
AE601
/4
8' - 6"
7' - 6"
8' - 4"
8' - 4"
1'-0"
2'-8 3/4"
4'-3" 7' - 4"
7' - 2"
7' - 2"
7' - 2"
7' - 2"
7' - 2"
7' - 2"
AE501
AE501
AE501
AE501
5' - 6"
5' - 6"
5' - 6"
5' - 6"
7' - 4"
7' - 4"
7' - 4"5' - 6"
5' - 6" 5' - 6"
7' - 4"
5' - 6"
7' - 4"
5' - 6" 5' - 6"
7' - 4"
5' - 6" 5' - 6"
7' - 4"
5' - 6"
5' - 6"
5' - 6"
5' - 6"
5' - 6"
5' - 6"
5' - 6"
5' - 6"
5' - 6"
9' - 0"
A331
9' - 0"
D344
4'-6 3/8"
AE501
AE501
AE501
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.TYP.TYP.
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
1' - 8 3/4" 1' - 0"
AE501
AE501
5' - 6"
7' - 4"
7' - 6"
7' - 11"
7' - 11"
8' - 10"
9' - 0"
6' - 6"
6' - 6"
P-4
P-4
P-4
P-4 P-4
P-14
P-7
P-3
P-7
P-14
P -4
P-4 P-4
P-4
P -1
P-7
P-3
P -3
P-14
P-7
P-4
P-4
P-4
P-4
P-4
P-4
P-4
P-4
P-4
P-4
P-4
P-13
P-13
P-13
P-13
P-13
P-13
P-13
P-13
P-13
P-4
P-4 P-4
P-4
P-13 P-13
P-13 P-13 P-13
P-13P-13P-13
P-13P-13
P-13 P-13P-13
P-13
P-13
P-13E
R 4' - 7"
7' - 4"
8' - 6"
9' - 0"
8'
6"
7' - 0"
7' - 0"
BID ITEM #3
(REF. GI001)
BID ITEM #3
(REF. GI001)
BID ITEM #3
(REF. GI001)
BID ITEM #3
(REF. GI001)
BID ITEM #3
(REF. GI001)
BID ITEM #3
(REF. GI001)
BID ITEM #2
(REF. GI001)
1'-8"
1'-8"
AE301
AE301
10.21
10.21 10.21 10.21
/8
1' - 4"
10.21
135°
135°2'-1 1/4"
10 3/4"
1'-1"
/8
/8
5'-9"
/2
135°
/8
18' - 3 3/8"
135°
5°
135°
135°
135°
1' - 0"
5°
/4
4' - 4 1/8"
/4
2' - 8 3/4"
1' - 4"
7' - 0"
1' - 4"
7' - 6"
10.21
9' - 0"
7' - 4"
7' - 11"
2' - 1"
AE501
7' - 0"
135°
135°
135°
5°
7' - 4" 7' - 0"
AE501
P-3 10.31F
10.31E
10.31E
10.31E
10.31E
THIRD FLOOR KEY PLAN - AREA A
A
N
A. REF. SPECIFICATION SECTION 13 05 41 "SEISMIC RESTRAINT REQUIREMENTS FOR NON-
STRUCTURAL COMPONENTS" FOR BRACING REQUIREMENTS FOR CEILINGS AND LIGHTING
FIXTURES
GENERAL RCP NOTES
CEILING ACCESS PANEL
WALL MOUNT FIXTURE
CEILING HEIGHT
SYMBOL LEGEND
RECESSED CAN FIXTURE
EX EXISTING CEILING
EXHAUST GRILLE
NOTE:
A. REFERENCE MECHANICAL & ELECTRICAL
DRAWINGS FOR SYMBOLS NOT SHOWN HERE.
B. ALL FIXTURES TO BE LED.
RETURN GRILLE
RETURN GRILLE
2X2 LED FIXTURE
EXHAUST GRILLE
SURFACE MOUNT FIXTURE
SUPPLY DIFFUSER
SUPPLY DIFFUSER
DUCT MOUNTED RETURN
DUCT MOUNTED SUPPLY
WALL WASH SLOT
SLOT DIFFUSER
RADIANT HEATER
SLOT DIFFUSER
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE110.3
REFLECTED CEILING PLAN - 3RD
FLOOR - AREA A - BID ITEM #3
(DEDUCT)
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
KEYNOTES
KEY VALUE KEYNOTE TEXT
10.21 CUBICLE CURTAIN TRACKS, REF SPEC
10.31E WALL MOUNTED HALF DOME SAFETY MIRROR
10.31F CEILING MOUNTED 360 DOME SAFETY MIRROR
1/8" = 1'-0"
REFLECTED CEILING PLAN - 3RD FLOOR - AREA A - BID ITEM #3 (DEDUCT)
N
Jesse Bell Snapshot
9' - 0" 9' - 0"
7'
0"
6'
6"
6' - 6"
9' - 0"
9' - 0" 9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
7'
0"
9' - 0"
9' - 0"
7' - 2"
7'
0"
8' - 4"
9' - 0"
7' - 0"
9' - 0"
8' - 6"
7' - 0"
9' - 0"
9' - 0"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
7' - 0"
D324
D324A
D323A
D323
D322
D322A
D321
D314
C3D5
D315
D316
D317
D317A
D318
D325
D340
D343
D343A
D343B
D341
D339
C3D4
D342
D338
C3D3
D337
D335
D333
D331
D329
D328
D327 D326
C3C4
D330
D332
D334
D336
8' - 4"
10.21
10.21
10.21
10.21
C3D3
7' - 9"9' - 0"
9' - 5 3/4"
8' - 9"
8' - 9"
9' - 5 3/4"
8' - 9"
9' - 5 3/4"
8' - 9"
9' - 5 3/4"
9' - 5 3/4"
9' - 5 3/4"
8' - 11"
8' - 11" 9' - 5 3/4"
9' - 5 3/4"
8' - 11"
9' - 5 3/4"
9' - 5 3/4"
8' - 11"
9' - 5 3/4"
7' - 0"
1'-4"
3'-6"
1'-4"
3'-6"
7' - 0"
7' - 0"
3'-6"
3'-6"
3'-6"
3'-6"
3'-6" 1'-4"
1'-4"
AE601
AE601
AE601
AE601
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE601
7' - 6"
7' - 11"2'-2"
7' - 0"
7' - 0"
2'-5"
AE501
8' - 4"
7' - 2"
3'-0"
1'-1"
AE501
8' - 4"
9' - 0"
TYP.
D321A
6' - 6"
6' - 6"
7' - 0"
P -4
P-1
P-13
P -1
P -1
P-13
P-13
P-13
P-13
P-13
P-13
P-1
P -1
P -1
P-1
P -1
P -1
P-13
P-13
P-13
P-13
P-4
P-4
P-4
P-4
P-13
P-13
P -1
P -1
1'-8"
P-13E
P-13E
P-13E
BID ITEM #3
(REF. GI001)
BID ITEM #3
(REF. GI001)
BID ITEM #2
(REF. GI001)
1'-4"
1'-4"
1'-8"
/2
7' - 4"
7' - 4"
7' - 4"
7' - 4"
11.73
11.73
11.73
11.73 11.73
1' - 4"
10.21 1' - 8"
AE410
Sim
AE410
7' - 9"
7' - 10"
8' - 11"
8' - 11"
8' - 11"
AE601
AE601
AE601
AE601
AE601
AE601
AE601
AE601
AE601
AE601
AE601
AE601
7' - 4"
9.10
9.10
9.10
9.10
9.10
9.109.10
9.10
OPEN TO
UNDERSIDE
OF DECK
CEILING ACCESS PANEL
WALL MOUNT FIXTURE
CEILING HEIGHT
SYMBOL LEGEND
RECESSED CAN FIXTURE
EX EXISTING CEILING
EXHAUST GRILLE
NOTE:
A. REFERENCE MECHANICAL & ELECTRICAL
DRAWINGS FOR SYMBOLS NOT SHOWN HERE.
B. ALL FIXTURES TO BE LED.
RETURN GRILLE
RETURN GRILLE
2X2 LED FIXTURE
EXHAUST GRILLE
SURFACE MOUNT FIXTURE
SUPPLY DIFFUSER
SUPPLY DIFFUSER
DUCT MOUNTED RETURN
DUCT MOUNTED SUPPLY
WALL WASH SLOT
SLOT DIFFUSER
RADIANT HEATER
SLOT DIFFUSER
THIRD FLOOR KEY PLAN - AREA B
BN
A. REF. SPECIFICATION SECTION 13 05 41 "SEISMIC RESTRAINT REQUIREMENTS FOR NON-
STRUCTURAL COMPONENTS" FOR BRACING REQUIREMENTS FOR CEILINGS AND LIGHTING
FIXTURES
GENERAL RCP NOTES
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE111
REFLECTED CEILING PLAN - 3RD
FLOOR - AREA B
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
KEYNOTES
KEY VALUE KEYNOTE TEXT
9.10 VERTICAL EXPANSION JOINT FOR PAINT BREAK
10.21 CUBICLE CURTAIN TRACKS, REF SPEC
11.73 CEILING MOUNTED PATIENT LIFT SYSTEM
1/8" = 1'-0"
REFLECTED CEILING PLAN - 3RD FLOOR - AREA B
N
A. REF. SPECIFICATION SECTION 13 05 41 "SEISMIC RESTRAINT REQUIREMENTS FOR NON-
STRUCTURAL COMPONENTS" FOR BRACING REQUIREMENTS FOR CEILINGS AND LIGHTING
FIXTURES
GENERAL RCP NOTES
THIRD FLOOR KEY PLAN - AREA B
BN
CEILING ACCESS PANEL
WALL MOUNT FIXTURE
CEILING HEIGHT
SYMBOL LEGEND
RECESSED CAN FIXTURE
EX EXISTING CEILING
EXHAUST GRILLE
NOTE:
A. REFERENCE MECHANICAL & ELECTRICAL
DRAWINGS FOR SYMBOLS NOT SHOWN HERE.
B. ALL FIXTURES TO BE LED.
RETURN GRILLE
RETURN GRILLE
2X2 LED FIXTURE
EXHAUST GRILLE
SURFACE MOUNT FIXTURE
SUPPLY DIFFUSER
SUPPLY DIFFUSER
DUCT MOUNTED RETURN
DUCT MOUNTED SUPPLY
WALL WASH SLOT
SLOT DIFFUSER
RADIANT HEATER
SLOT DIFFUSER
9' - 0"
9' - 0"
7'
0"
6'
6"
6' - 6"
9' - 0"
9' - 0" 9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0" 9' - 0"
9' - 0"
9' - 0"
9' - 0"
7' - 0"
9' - 0"
9' - 0"
7' - 2"
7'
0"
8' - 4"
9' - 0"
7' - 0"
9' - 0"
8' - 6"
7' - 0"
9' - 0"
9' - 0"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"
8' - 10"7' - 0"
D324
D324A
D323A
D323
D322
D322A
D321
D314
C3D5
D315
D316
D317 D317A
D318
D325
D340
D343
D343A
D343B
D341
D339
C3D4
D342
D338
C3D3
D337
D335
D333
D331
D329
D328
D327 D326
C3C4
D330
D332
D334
D336
8' - 4" 10.21
10.21
10.21
10.21
C3D3
7' - 9"
9' - 0"
9' - 5 3/4"
8' - 9"
8' - 9"
9' - 5 3/4"
8' - 9"
9' - 5 3/4"
8' - 9"
9' - 5 3/4"
9' - 0"
9' - 5 3/4"
9' - 5 3/4"
8' - 11"
8' - 11"
9' - 5 3/4"
9' - 0"
9' - 5 3/4"
8' - 11"
9' - 5 3/4"
9' - 5 3/4"
8' - 11"
9' - 5 3/4"
7' - 0"
1'-4"
3'-6"
1'-4"
3'-6"
7' - 0"
7' - 0"
3'-6"
3'-6"
3'-6"
3'-6"
3'-6"1'-4"
1'-4"
AE601
AE601
AE601
AE601
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE501
AE601
8' - 10"
7' - 6"
7' - 11"2'-2"
7' - 0"
7' - 0"
2'-5"
AE501
8' - 4"
7' - 2"
3'-0"
1'-1"
7' - 2"
AE501
5' - 6"
5' - 6"
7' - 4"
8' - 4"
9' - 0"
TYP.
TYP.
TYP.
TYP.
5' - 6"
D321A
6' - 6"
6' - 6"
7' - 0"
P -4
P-1
P-13
P -1
P -1
P-13
P-13
P-13
P-13
P-13
P-13
P-1
P -1
P -1
P-1
P -1
P -1
P-13
P-13
P-13
P-13
P-4
P-4
P-4
P-4
P-13
P-13
P -1
P -1
1'-8"
P-13E
P-13E
P-13E
BID ITEM #3
(REF. GI001)
BID ITEM #3
(REF. GI001)
BID ITEM #2
(REF. GI001)
1' - 4"
1' - 8"
1' - 4"
10.21
1' - 8"
1' - 4"
8' - 11"
7' - 10"
8' - 4"
10.2110.21
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE111.3
REFLECTED CEILING PLAN - 3RD
FLOOR - AREA B - BID ITEM #3
(DEDUCT)
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
KEYNOTES
KEY VALUE KEYNOTE TEXT
10.21 CUBICLE CURTAIN TRACKS, REF SPEC
N
1/8" = 1'-0"
REFLECTED CEILING PLAN - 3RD FLOOR - AREA B - BID ITEM #3 (DEDUCT)
ABCDEFG
2.8
3.7
7.3
8.2
9.1
10.4
4.5
Ba
4.6
6.3
8.0
1.9
5.5
1.1
F.1 E.a2 Aa
PAT. ROOM
FIRST FLOOR ROOF BELOW
M E
C H
A N
IC
A
L R
O O
M
F
IR
S T
F L O
O R
R O
O F
THIRD FLOOR ROOF
FIRST FLOOR ROOF BELOW
EX
D455A
AE120
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
AE301
AE301
23.0823.0823.0823.08
23.0823.08
7.72
7.72
7.72
5.50C
5.50C
23.03
5.51
5.51
7.51
23.02
23.02
23.01
23.03
23.01
23.01
23.01
23.02 7.72
7.72
7.72
7.72
AE501
AE501
TYP
AE501
TYP
AE501
TYP
AE501
TYP
AE501
TYP
AE501
TYP
AE120
AE501
4TH LEVEL
39' - 1 1/4"
3 EQUAL RISERS
@ ~8" EA.
2 EQUAL RISERS
@ ~9" EA.
EXISTING WINDOW SILL HEIGHT, GC
TO FIELD VERIFY DIMENSIONS
EXISTING OPENING AT EXTERIOR WALL
Level 4 39' - 1 1/4"
AE501
Sim
AE501
AE501
Sim
F
4.5
4.6
F.1 E.a2
AE120
11" 11" 4' - 7" 4' - 8" 11"
A. PROVIDE AND INSTALL 600 LINEAL FEET OF 30" WIDE 5/16" THICK COMPRESSED WHITE
RUBBER WALKWAY ROLL MATERIAL AS MANUFACTURED BY "CARLISLE" OR APPROVED
EQUAL. LOCATIONS TO BE DETERMINED AT A LATER DATE
B. REFER TO MECH. ROOF PLAN SHEET FOR ADDITIONAL INFORMATION INDICATING LOCATIONS
OF EXHAUST FANS, VENTS AND OTHER ROOF PENETRATIONS.
C. PROVIDE TAPERED INSULATION CRICKETS AT UPSLOPE SIDE OF ALL ROOF CURBS PER
ROOFING MFG'S RECOMMENDATIONS.
D. FLASH ALL ROOF CURBS, PENETRATIONS, ETC. PER ROOFING MANUFACTURER
RECOMMENDATIONS - REFER TO/COORDINATE WITH MECHANICAL AND PLUMBING PLANS
AND FLASH ALL NEW PENETRATIONS AS REQUIRED.
GENERAL ROOF PLAN NOTES
NEW TAPERED POLY ISO
MINIMUM R-49 AND SLOPED 1/4"
PER FOOT FROM DRAIN
NEW 1/2" COVER BOARD
NEW FULLY ADHERED EPDM MEMBRANE,
OVERLAPPING THE EXISTING
STAINLESS STEEL CLAMPING RING
PRE-MOLDED PRESSURE
SENSITIVE PIPE SEAL
WATER CUT-OFF MASTIC
SEAMING/TERMINATION
ADHESIVE PER MEMBRANE
SUPPLIER
STEEL FALL PROTECTION ANCHOR
REF. STRUCTURAL FOR
ANCHORAGE REQUIREMENTS
NEW VAPOR BARRIER
EXISTING CONCRETE ROOF
STRUCTURE
CDE
5.5
AE301
2' - 0"
AE501
AE501
TYP
AE501
TYP
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE120
ROOF PLAN
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
N
3/32" = 1'-0"
ROOF PLAN
1/4" = 1'-0"
NEW ROOF ACCESS STAIR
1/4" = 1'-0"
ENLARGED PLAN - ROOF ACCESS STAIRS
KEYNOTES
KEY VALUE KEYNOTE TEXT
5.50C METAL EQUIPMENT SCREENING SYSTEM, REF STRUCTURAL FOR ATTACHMENT TO
RTU SUPPORT FRAMING
5.51 METAL STAIRS
7.51 WALKWAY PAD
7.72 FALL ARREST SYSTEM, SEE STRUCTURAL FOR ANCHORING REQUIREMENTS, REF
SPEC.
23.01 MECH ELEMENT - SEE MECH DRAWINGS.
23.02 MECH DUCT - SEE MECH.
23.03 ROOFTOP UNIT - SEE MECH.
23.08 EXISTING EXUAST FAN - SEE MECH, PAINT TO MATCH NEW RTU
1 1/2" = 1'-0"
DETAIL @ FLAT ROOF - FALL PROTECTION
3/32" = 1'-0"
ROOF PLAN - RTU PENETRATIONS
ABCDEFG
2.8
3.7
7.3
8.2
9.1
10.4
4.5
Ba
4.6
6.3
8.0
1.9
5.5
1.1
F.1 E.a2 Aa
FIRST FLOOR ROOF BELOW
M E
C H
A N
IC
A
L R
O O
M
F
IR
S T
F L O
O R
R O
O F
THIRD FLOOR ROOF
FIRST FLOOR ROOF BELOW
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
7.51
2' - 6"
AE301.2
AE301.2
23.01
23.03
23.01
23.01
23.01
23.0823.0823.0823.08
23.0823.08
7.51
23.02
23.02
23.02
AE501
AE501
TYP
AE501
TYP
AE501
TYP
AE501
TYP
AE501
TYP
AE501
TYP
AE120.2
Sim
AE501
A. PROVIDE AND INSTALL 600 LINEAL FEET OF 30" WIDE 5/16" THICK COMPRESSED WHITE
RUBBER WALKWAY ROLL MATERIAL AS MANUFACTURED BY "CARLISLE" OR APPROVED
EQUAL. LOCATIONS TO BE DETERMINED AT A LATER DATE
B. REFER TO MECH. ROOF PLAN SHEET FOR ADDITIONAL INFORMATION INDICATING LOCATIONS
OF EXHAUST FANS, VENTS AND OTHER ROOF PENETRATIONS.
C. PROVIDE TAPERED INSULATION CRICKETS AT UPSLOPE SIDE OF ALL ROOF CURBS PER
ROOFING MFG'S RECOMMENDATIONS.
D. FLASH ALL ROOF CURBS, PENETRATIONS, ETC. PER ROOFING MANUFACTURER
RECOMMENDATIONS - REFER TO/COORDINATE WITH MECHANICAL AND PLUMBING PLANS
AND FLASH ALL NEW PENETRATIONS AS REQUIRED.
GENERAL ROOF PLAN NOTES
CDE
5.5
AE301.2
AE501
2' - 0"
AE501
TYP
AE501
TYP
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE120.2
ROOF PLAN - BID ITEM #2 (DEDUCT)
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
N
3/32" = 1'-0"
ROOF PLAN - BID ITEM #2 (DEDUCT)
KEYNOTES
KEY VALUE KEYNOTE TEXT
7.51 WALKWAY PAD
23.01 MECH ELEMENT - SEE MECH DRAWINGS.
23.02 MECH DUCT - SEE MECH.
23.03 ROOFTOP UNIT - SEE MECH.
23.08 EXISTING EXUAST FAN - SEE MECH, PAINT TO MATCH NEW RTU
3/32" = 1'-0"
ROOF PLAN - RTU PENETRATIONS - BID ITEM #2 (DEDUCT)
3RD LEVEL
26' - 5 1/4"
4TH LEVEL
39' - 1 1/4"
SIXTH FLOOR
64' - 5 1/4"
PENTHOUSE
77' - 1 1/4"
842-10 1/8 TOP OF COPING
106' - 10 1/8"
122.833.74577.38.299.11011 10.412
4.56.2 5.46.7 4.66.38.0 1.95.5 1.14.4
NEW ROOF ACCESS DOOR
& STAIRS
BID ITEM #2
(REF. GI001)
AE301
7.727.727.72 23.01
5.50C
23.01
7.72
23.0123.01 7.72
AE501
3RD LEVEL
26' - 5 1/4"
4TH LEVEL
39' - 1 1/4"
FIFTH FLOOR
51' - 9 1/4"
SIXTH FLOOR
64' - 5 1/4"
PENTHOUSE
77' - 1 1/4"
842-10 1/8 TOP OF COPING
106' - 10 1/8"
ABCDEFGGaHHbJ BaH.5 F.1 E.a2 Aa
NEW ROOF ACCESS STAIRS
BID ITEM #2
(REF. GI001)
AE301
5.50C
7.72 7.72
23.0123.01
5.51
23.0823.08
5.51
5.43
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE201
EXTERIOR ELEVATIONS
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
1/8" = 1'-0"
PARTIAL EAST BUILDING ELEVATION
1/8" = 1'-0"
PARTIAL SOUTH BUILDING ELEVATION
KEYNOTES
KEY VALUE KEYNOTE TEXT
5.43 METAL GUARDRAIL / HANDRAIL.
5.50C METAL EQUIPMENT SCREENING SYSTEM, REF STRUCTURAL FOR ATTACHMENT TO
RTU SUPPORT FRAMING
5.51 METAL STAIRS
7.72 FALL ARREST SYSTEM, SEE STRUCTURAL FOR ANCHORING REQUIREMENTS, REF
SPEC.
23.01 MECH ELEMENT - SEE MECH DRAWINGS.
23.08 EXISTING EXUAST FAN - SEE MECH, PAINT TO MATCH NEW RTU
3RD LEVEL
26' - 5 1/4"
4TH LEVEL
39' - 1 1/4"
SIXTH FLOOR
64' - 5 1/4"
PENTHOUSE
77' - 1 1/4"
842-10 1/8 TOP OF COPING
106' - 10 1/8"
122.833.74577.38.299.11011 10.412
4.56.2 5.46.7 4.66.38.0 1.95.5 1.14.4
BID ITEM #2
(REF. GI001)
AE301
23.03
5.03C
23.01
23.0123.01 23.0123.01
AE501
3RD LEVEL
26' - 5 1/4"
4TH LEVEL
39' - 1 1/4"
FIFTH FLOOR
51' - 9 1/4"
SIXTH FLOOR
64' - 5 1/4"
PENTHOUSE
77' - 1 1/4"
842-10 1/8 TOP OF COPING
106' - 10 1/8"
ABCDEFGGaHHbJ BaH.5 F.1 E.a2 Aa
BID ITEM #2
(REF. GI001)
AE301
23.0123.0123.03
23.08
23.08
5.03C5.43
5.51
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE201.2
EXTERIOR ELEVATIONS - BID ITEM #2
(DEDUCT)
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
1/8" = 1'-0"
PARTIAL EAST BUILDING ELEVATION - BID ITEM #2 (DEDUCT)
1/8" = 1'-0"
PARTIAL SOUTH BUILDING ELEVATION - BID ITEM #2 (DEDUCT)
KEYNOTES
KEY VALUE KEYNOTE TEXT
5.03C STRUCTURAL STEAL FRAME WORK FOR RTU SUPPORT, REF STRUCTURAL
5.43 METAL GUARDRAIL / HANDRAIL.
5.51 METAL STAIRS
23.01 MECH ELEMENT - SEE MECH DRAWINGS.
23.03 ROOFTOP UNIT - SEE MECH.
23.08 EXISTING EXUAST FAN - SEE MECH, PAINT TO MATCH NEW RTU
2ND LEVEL
13' - 9 1/4"
2ND LEVEL
13' - 9 1/4"
3RD LEVEL
26' - 5 1/4"
3RD LEVEL
26' - 5 1/4"
4TH LEVEL
39' - 1 1/4"
4TH LEVEL
39' - 1 1/4"
FIFTH FLOOR
51' - 9 1/4"
SIXTH FLOOR
64' - 5 1/4"
PENTHOUSE
77' - 1 1/4"
ABCDEF BaF.1 E.a2 Aa
CORR.
C3A3
MSA
D302
STRETCHER
D303
PAT. RM #4
D304
PAT. RM #6
D306
PAT. RM #8
D308
PAT. RM #10
D310
PAT. RM #12
D312
STRETCHER
D309
CORR.
C3A5
ANTE
D319B
ISO/BAR #19
D319
SHADED AREA NOT IN
SCOPE OF PROJECT
SHADED AREA NOT IN
SCOPE OF PROJECT
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
5.51
23.03
5.03C
AE301
5.50C
BID ITEM #2
(REF. GI001)
7.72
BID ITEM #2
(REF. GI001)
5.51
5.43
2ND LEVEL
13' - 9 1/4"
2ND LEVEL
13' - 9 1/4"
3RD LEVEL
26' - 5 1/4"
3RD LEVEL
26' - 5 1/4"
4TH LEVEL
39' - 1 1/4"
4TH LEVEL
39' - 1 1/4"
3.7 4 5 6 7 7.34.5 4.6 6.35.5
THIRD FLOOR - ACA
33' - 0 1/2"
THIRD FLOOR - ACA
33' - 0 1/2"
AE301
SHADED AREA NOT IN
SCOPE OF PROJECT
PAT. RM #9
A309 CORR.
C3A4
PAT. RM #8
D308
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
5.50C
23.03
5.03C
23.01
23.02
23.01
7.72
23.02
7.727.7215
AE501
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE301
BUILDING SECTIONS
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
1/8" = 1'-0"
E/W SECTION @ NEW RTU UNIT
1/8" = 1'-0"
N/S SECTION @ NEW RTU
KEYNOTES
KEY VALUE KEYNOTE TEXT
5.03C STRUCTURAL STEAL FRAME WORK FOR RTU SUPPORT, REF STRUCTURAL
5.43 METAL GUARDRAIL / HANDRAIL.
5.50C METAL EQUIPMENT SCREENING SYSTEM, REF STRUCTURAL FOR ATTACHMENT TO
RTU SUPPORT FRAMING
5.51 METAL STAIRS
7.72 FALL ARREST SYSTEM, SEE STRUCTURAL FOR ANCHORING REQUIREMENTS, REF
SPEC.
23.01 MECH ELEMENT - SEE MECH DRAWINGS.
23.02 MECH DUCT - SEE MECH.
23.03 ROOFTOP UNIT - SEE MECH.
2ND LEVEL
13' - 9 1/4"
2ND LEVEL
13' - 9 1/4"
3RD LEVEL
26' - 5 1/4"
3RD LEVEL
26' - 5 1/4"
4TH LEVEL
39' - 1 1/4"
4TH LEVEL
39' - 1 1/4"
FIFTH FLOOR
51' - 9 1/4"
SIXTH FLOOR
64' - 5 1/4"
PENTHOUSE
77' - 1 1/4"
ABCDEF BaF.1 E.a2 Aa
CORR.
C3A3
MSA
D302
STRETCHER
D303
PAT. RM #4
D304
PAT. RM #6
D306
PAT. RM #8
D308
PAT. RM #10
D310
PAT. RM #12
D312
STRETCHER
D309
CORR.
C3A5
ANTE
D319B
ISO/BAR #19
D319
SHADED AREA NOT IN
SCOPE OF PROJECT
SHADED AREA NOT IN
SCOPE OF PROJECT
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
AE301.2
23.03
5.03C
23.02
23.01
23.02
BID ITEM #2
(REF. GI001)
2ND LEVEL
13' - 9 1/4"
2ND LEVEL
13' - 9 1/4"
3RD LEVEL
26' - 5 1/4"
3RD LEVEL
26' - 5 1/4"
4TH LEVEL
39' - 1 1/4"
4TH LEVEL
39' - 1 1/4"
3.7 4 5 6 7 7.34.5 4.6 6.35.5
THIRD FLOOR - ACA
33' - 0 1/2"
THIRD FLOOR - ACA
33' - 0 1/2"
AE301.2
SHADED AREA NOT IN
SCOPE OF PROJECT
PAT. RM #9
A309 CORR.
C3A4
PAT. RM #8
D308
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
BID ITEM #2
(REF. GI001)
23.03
23.01
5.03C
23.02
23.02
23.01
AE501
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE301.2
BUILDING SECTIONS - BID ITEM #2
(DEDUCT)
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
KEYNOTES
KEY VALUE KEYNOTE TEXT
5.03C STRUCTURAL STEAL FRAME WORK FOR RTU SUPPORT, REF STRUCTURAL
23.01 MECH ELEMENT - SEE MECH DRAWINGS.
23.02 MECH DUCT - SEE MECH.
23.03 ROOFTOP UNIT - SEE MECH.
1/8" = 1'-0"
E/W SECTION @ NEW RTU UNIT - BID ITEM #2 (DEDUCT)
1/8" = 1'-0"
N/S SECTION @ NEW RTU - BID ITEM #2 (DEDUCT)
A. FILL SURFACE OF CONCRETE WALLS WITH AN APPROPRIATE FILLER AND MAKE SMOOTH.
SEAL OR PRIME ABSORBANT SURFACES WITH A SUITABLE DILUITED ACRYLIC PRIMER.
ALLOW PAINT/PRIMER TO DRY IN ACCORDANCE WITH THE MANUFACTURERS APPLICATION
INSTRUCTIONS. UNFILLED GROUT LINES MAY TELEGRAPH THROUGH THE SHEET; GC TO
CORDINATE WITH MAUNFACTURER PROPER THICKNESS AND INSTALLATION METHOD.
B. GYPSUM WALLS NEED TO BE PAINTED PRIOR TO INSTALLATION OF PLYWOOD.
C. CONSTRUCT NEW RATED 1-HR SHAFT WALL FROM 3RD FLOOR TO 4TH FLOOR. CONSTRUCT
1-HR RATED CHASE AROUND DUCT AND PIPING TRANSITION THROUGH 4TH FLOOR SLAB.
D. REF. SHEETS AE402 & AE403 FOR SLOPING OF PATIENT ROOM TOILET FLOORS
GENERAL PLAN NOTES
C
1'-8 3/8" 7'-7 3/8"
/8
/8
/4
9'-3 3/4"
TLT.
A338 P3
FS3
FS3
FS3
FS6 P31 A338
P31
AI7079
SIM
10SIM
SIM
12SIM
C
Ba
5.5
AI703
AI703
AI703
AI703
AI70311
AI703
AI703
AI703
AI703 10
AI703
AI703
NOUR.
A334
NURSE
WK/COPY
A333
NURSE
A332
CORR.
C3A4
CORR.
C3A6
C
A
A
F2
F2
F2
F3
F3
P3
P3
P3
F2
FS3
PS3
F3
FS3
F2
14.92
F2
F3
F3
F2
F2
F2
P31
P3
P31
/8
/4
/4
/8
CORR.
C3A5
P31
P31
5' - 4 3/4" 2' - 8 1/2"
12' - 0 3/4"
5'
7/
8"
/2
/4
/4
F3
F3
F3
AE601
MEDS
A335
STRETCHER
D309
2" RADIUS C-TOP
2" RADIUS C-TOP
2" RADIUS C-TOP
2" RADIUS C-TOP
2" RADIUS C-TOP
1" RADIUS LEDGE
C
8.0
AI703
AI70321
AI703
AI703
AI703 19
P3 P3F2
F2
F2
F2
P6
/8
9'-3 3/4"
NURSE
D314
2' - 1" 4' - 7 3/8" 2' - 8 1/2"
F3
F3
F3
2" RADIUS C-TOP
2" RADIUS C-TOP
2" RADIUS C-TOP
Ga
F.1 E.a2
AI70225
AI70213
AI702
AI702
AI702
AI702
2'-9 5/8"
NURSE
A328
NURSE
WK/COPY
A329
NOUR.
A324
A
P3
P8
F2
S21
F2
F2
F2
P3
S21
CORR.
C3A3
AI702 17
AI702 23
AI702 11
MSA
D302
CORR.
C3A2
CORR.
C3A4
P3
P3
P3
P3
P3
F2
F2
F2
P3
P6
F3
PS3
FS3
F2
P3
P3
P6
F3
F3
PS3
P3
P3
/8
2'-8 1/2" 6'-0 1/8" 2'-1"
10'-7 1/4"
10'-0 5/8"
2'-8 1/2" 5'-11 1/4"
/8
4' -7
/8
5'-5 7/8"
/8
/4
A
22.41
14.92
5.54
5.58
F2
FS3
F3
5.58
AE501
SIM
AE501
TYP
AE501
TYP
AE501
TYP
AE501
TYP
CORR.
C3A1
MEDS
A319
C L
E A
N L
IN
E
N
A
STRETCHER
D303
GaH
8.0
AI7029
AI702
AI7026
D342
C3A3
SOILED
D342A
DIALYSIS
D342
F2
F2
F2
P6
P31
P31
P31
F2
P31
FS3
F2
F2 F3
F2
F2
/8
11 5/8" 2'-9 3/8" 5'-10" 11'-4 1/8"
AE501
Sim
P3
F3
P3
/8
/8
/2
45.00°
P61
P3
10.44DIALYSIS
STOR.
D342B
C
AI707
9 11
/8
1'-8 3/8" 7'-7 3/8"
P31
FS3
FS3
P3
F2
D318TLT.
D318
/8
9'-3 3/4"
F6
FS3
F
F.1
AI707
AI701 6
AI707
AI7015
3 1
5 7
/8
/8
10.51
10.51
F2
F2 P3
F2
P31
F2
P3
P3
P3
P3
P31
/4
6'-4 1/4"
11 5/8"
3'-9 1/4"
/8
/8
D
B
D341
STAFF
LOUNGE
D343
TLT.
D341
LOCKER
D343A
CHG ROOM
D343B
F3
FS3 F3
P31
F3
F3
P3
P3
P3
8.33
AE601
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE401
ENLARGED PLANS
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
KEYNOTES
KEY VALUE KEYNOTE TEXT
5.54 FLOOR EXPANSION JOINT ASSEMBLY, REF. SPEC
5.58 WALL EXPANSION JOINT ASSEMBLY, REF. SPEC
8.33 FROSTED WINDOW FILM, APPLIED TO THE EXISTING WINDOW
10.44 FIRE EXTINGUISHER CABINET
10.51 METAL "Z" LOCKERS
14.92 PNEUMATIC TUBE SYSTEM
22.41 EYEWASH STATION - SEE PLUMBING.
1/4" = 1'-0"
ENLARGED - A338 TLT.
1/4" = 1'-0"
ENLARGED - A332 NURSE STATION & A333 NURSE WK/COPY
1/4" = 1'-0"
ENLARGED - D314 NURSE STATION
1/4" = 1'-0"
ENLARGED - A328 NURSE STATION & D302 MSA
1/4" = 1'-0"
ENLARGED - D342 DIALYSIS
1/4" = 1'-0"
ENLARGED - D318 TLT.
1/4" = 1'-0"
ENLARGED - D343A LOCKER, D343B, & D341
A. FILL SURFACE OF CONCRETE WALLS WITH AN APPROPRIATE FILLER AND MAKE SMOOTH.
SEAL OR PRIME ABSORBANT SURFACES WITH A SUITABLE DILUITED ACRYLIC PRIMER.
ALLOW PAINT/PRIMER TO DRY IN ACCORDANCE WITH THE MANUFACTURERS APPLICATION
INSTRUCTIONS. UNFILLED GROUT LINES MAY TELEGRAPH THROUGH THE SHEET; GC TO
CORDINATE WITH MAUNFACTURER PROPER THICKNESS AND INSTALLATION METHOD.
B. GYPSUM WALLS NEED TO BE PAINTED PRIOR TO INSTALLATION OF PLYWOOD.
C. CONSTRUCT NEW RATED 1-HR SHAFT WALL FROM 3RD FLOOR TO 4TH FLOOR. CONSTRUCT
1-HR RATED CHASE AROUND DUCT AND PIPING TRANSITION THROUGH 4TH FLOOR SLAB.
D. REF. SHEETS AE402 & AE403 FOR SLOPING OF PATIENT ROOM TOILET FLOORS
GENERAL PLAN NOTES
B
3.7
C
A 5 A
A
A317
/2
/8
10 5/8"
8'-6 3/4"
/8
/4
/8
1'-1 1/2" 2'-7 1/2"
FS3
F2
F3
P3
P3
P31
PS61
P31
F3
FS3
PS31
P81
PS3
TLT./SHWR
A316A
P31
F3
P3 2' - 6"
PS31
8.04A
B
4.6
/8
/8
/4
/8
1'-1 1/8" 11 1/4"
5'-6 3/8" 3'-0 5/8" A318
A
A
A317
/8
/8
2'-5" 4'-4"
7 5/8"
3'-2 3/4"
PS3
PS3
PS6
F3
F3
FS3
F0
FS3
F3
P8PS3
TLT./SHWR
A317A
AE501
AE501
13 2' - 6"
P3
/4
F1
5.12
8.04A
B
5.5
/8
/4
/8
/8
/8
/4
A318
A
A
D319A
D319B
2'-0 1/8" 4'-4" 5 1/8" 4'-2 3/4"
/8
/2
/2
/4
135°
11 5/8"
6'-7 1/8" D319
6'-5 3/8"
/4 " P8
PS3
PS3PS3
FS3
F3
F3
PS6
P3 P3
PS3
F3
FS3
PS3
P3
P3
PS3
FS6
FS3
TLT./SHWR
D319A
TLT./SHWR
A318A
AI706
AI706
AI706
29 26
4' - 0"
F3
P3
P3
8.04A
3'-5 3/8" 2'-9 1/8"
10"
/8
/4
/8
/8
/8
1'-4 1/8" 5'-8 1/4"
A311A P3
F3
PS3
FS3
F3
PS3
FS3
F2
PS6
P3
TLT./SHWR
A311A
P3
F3
F3
E
3'-5 3/8" 2'-9 1/8"
10" 9 1/8"
2'-10 1/4" 3'-5 3/8"
10 5/8" 6'-1 7/8" 6'-1 7/8" 11 3/8"
/8
/8
/8
/2
/8
/8 " 1
/4
/8
"2
/8
A307A A309A
P3
FS3FS3
F3
F2 F2
PS6
F3
F3
FS3
FS3
P8 F3
F3
PS6
P3
PS3
TLT./SHWR
A307A
TLT./SHWR
A309A
PS3
2'-9 7/8" 3'-2 1/2"
AI501
AI501
F
F.1 E.a2
/8
/8
/2
" 1
/8
/8
/2
A305A
4'-0 1/2"
PS3 F2
F3
F2
FS3
F3 F3
P6
TLT./SHWR
A305A
F2F2
P3
PS6
P6
F3
FS3
PS3
5.58
5.54
5.58
AE501
TYP
AE501
SIM
AE501
TYP
3'-0 1/8"
AI501
GGa
AI7067
/8
A303
A303A
PS3PS6
FS3
FS3
TLT./SHWR
A303A
TLT./SHWR
A302A
AI706
2' - 1 1/2" 6' - 5 3/8"
9 1/8"
4' - 9 3/8" 1' - 10 1/4"
1' - 1 1/4"
PS6
PS3F2
PS3
P3
P3
P3
PS3
PS3
FS3
F2
PS6
FS2
P3 F2
P3
F2 F2
FS3
P3
P3
P3
A302A
PS3
/8
/8
/4
/2
/8
/4
2' - 1 1/2" 7' - 0 1/8" 8 5/8" 6' - 4 1/4" 10 1/4"
F6
P6
J
AI706 1
A
A
A301
A301B
9'-0 7/8"
11 1/4"
/8
/4
/8
/4
/2
P3
P3
PS3F6
PS3
FS3
F3
P3
F2
FS3
PS6
P6
TLT./SHWR
A301A
4'-2" 5 1/8" 4'-4" 1'-9 7/8"
F3
3'-6 3/4"
AI501
J
A301A
1/8"
1/8"
1/8"
1"
1"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
GGa
A303A
A302A
7/8"
7/8"
1/8"
3/8"
1/8"
3/8"
3/8"
1/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
1/8" 1"1"
3/8"
1/8"
3/8"
3/8"
1/8"
3/8"
3/8"
F
F.1 E.a2
A305A
5/8"
1/8"
5/8"
3/8"
3/8"
3/8"
1/8"
3/8"
3/8"
3/8"
3/8"
1/8"
3/8"
E
A307A A309A
5/8"1/8"5/8"
3/8"
1/8"
3/8"
1/8"
3/8"
3/8"
3/8"3/8"
3/8"5/8"3/8"1/8"5/8"
3/8"
3/8"
1/8"
1/8"
3/8"
3/8" 3/8" 3/8" 3/8"3/8"
A311A
1/8"
1/8"
1/8"
5/8"
3/8"
5/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
B
5.5
D319A
A318A
1/8"
3/8"
3/8" 1"
1/8"
1"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
1/8"
1"
3/8"
1/8"
1"
3/8"
1/8"
3/8"
1/8"
3/8"3/8"3/8"
B
3.7
A316A
5/8"
1/8"
5/8"
3/8"
3/8"
1/8" 3/8"
3/8"
3/8"
3/8" 3/8"
1/8"
3/8"
B
4.6 A317A
1/8"
1/8"
1/8"
5/8"
5/8"
3/8" 3/8"
3/8"
3/8"
3/8" 3/8"
3/8"
3/8"
3/8"
3/8"
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE402
ENLARGED PLANS - PATIENT TOILETS
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
KEYNOTES
KEY VALUE KEYNOTE TEXT
5.12 3'-6" PARTIAL HEIGHT WALL
5.54 FLOOR EXPANSION JOINT ASSEMBLY, REF. SPEC
5.58 WALL EXPANSION JOINT ASSEMBLY, REF. SPEC
8.04A 16"X16" NON-RATED PLUMBING ACCESS PANEL
1/4" = 1'-0"
ENLARGED - A316A TLT.
1/4" = 1'-0"
ENLARGED - A317A TLT.
1/4" = 1'-0"
ENLARGED - A318A & D319A TLT.
1/4" = 1'-0"
ENLARGED - A311A TLT.
1/4" = 1'-0"
ENLARGED - A307A & A309A TLT.
1/4" = 1'-0"
ENLARGED - A305A TLT.
1/4" = 1'-0"
ENLARGED - A302A & A303A TLT.
1/4" = 1'-0"
ENLARGED - A301A TLT.
1/4" = 1'-0"
A301A TLT. - SLOPED FLOOR
1/4" = 1'-0"
A302A & A303A TLT. - SLOPED FLOOR
1/4" = 1'-0"
A305A TLT. - SLOPED FLOOR
1/4" = 1'-0"
A307A & A309A TLT. -SLOPED FLOOR
1/4" = 1'-0"
A311A TLT. - SLOPED FLOOR
1/4" = 1'-0"
A318A & D319A TLT. - SLOPED FLOOR
1/4" = 1'-0"
A316A TLT. - SLOPED FLOOR
1/4" = 1'-0"
A317A TLT. - SLOPED FLOOR
B
2.8
A
A
A315
A316
/8
/4
/2
/8
2'-3 1/8" 4'-4"
5 1/2"
2'-8 1/4" 1'-6 3/4"
/2
/8
/8
1'-1 1/8" 11 1/4"
8'-11 5/8"
TLT./SHWR
A315A
F2
F2
F3
PS3
PS3
FS3
F3
P3
P3
P8
PS6
P3
F3
P3
P3 PS3
F2
4' - 0"
8.04A
AI501
B
2.8
A315A
1/8"
1/8"
1/8"
1"
3/8"
1"
3/8" 3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
BBa
1.9
/8
/8
1'-6 1/8" 11 1/4" 5'-1 3/8" 3'-0"
2'-1" 4'-4"
11 5/8"
3'-2 1/8"8
/8
/8
/4
/8
/8
TLT./SHWR
A314A
F0
FS3
F3PS3
F3
F3
FS3
PS6
PS3
PS3
F3
P8
A314 A
A
PS3
P31
/4
2' - 6"
A313
5.12
8.04A
BBa
1.9
A314A
1/8"
1/8" 5/8"
5/8"
3/8"
3/8"3/8"
3/8"
3/8"
1/8" 3/8"
3/8"
3/8"
3/8"
B
1.1
A
A
A
/8
/8
10" 6'-5 3/8" 3'-5 1/4"
/8
/8
P3
PS3
FS6
F6
FS3
FS3
FS3
P62
P3
TLT./SHWR
A313A
AI706
17 19
P3
PS3
/8
F3
FS3
5°
135°
A. FILL SURFACE OF CONCRETE WALLS WITH AN APPROPRIATE FILLER AND MAKE SMOOTH.
SEAL OR PRIME ABSORBANT SURFACES WITH A SUITABLE DILUITED ACRYLIC PRIMER.
ALLOW PAINT/PRIMER TO DRY IN ACCORDANCE WITH THE MANUFACTURERS APPLICATION
INSTRUCTIONS. UNFILLED GROUT LINES MAY TELEGRAPH THROUGH THE SHEET; GC TO
CORDINATE WITH MAUNFACTURER PROPER THICKNESS AND INSTALLATION METHOD.
B. GYPSUM WALLS NEED TO BE PAINTED PRIOR TO INSTALLATION OF PLYWOOD.
C. CONSTRUCT NEW RATED 1-HR SHAFT WALL FROM 3RD FLOOR TO 4TH FLOOR. CONSTRUCT
1-HR RATED CHASE AROUND DUCT AND PIPING TRANSITION THROUGH 4TH FLOOR SLAB.
D. REF. SHEETS AE402 & AE403 FOR SLOPING OF PATIENT ROOM TOILET FLOORS
GENERAL PLAN NOTES
B
1.1
A313A
3/8"
3/8" 3/8"
1/8" 3/8"
3/8"
3/8"
1"
1"
3/8"
1/8"
3/8"
1/8"
3/8"
3/8"
F
F.1 E.a2
/4
/4
/4
/8
/8
/8
/2
1'-3 7/8"
2'-0 7/8"
3'-5 3/8"
P3
F3
F3
FS3
P3
PS3
F2
F2
F2 F2
F2
D304A
TLT./SHWR
D304A
AI706 16
F2
P6
FS3
P3
PS3 F2
5.58
5.54
AE501
TYP
AE501
TYP
AE501
SIM
8.04B
AI501
1'-8"
F
F.1 E.a2
D304A
3/8"
3/8"3/8"
1/8"
1/8"
3/8"
5/8" 5/8"
1/8"
3/8"
3/8"
3/8"
3/8"
E
/4
/4
/8
/2
/8
/8
/4
/8
/8
3'-5 3/8" 3'-7 1/8" 3'-7 1/8" 3'-5 3/8"
D308A D306A
10 5/8"
6'-1 7/8" 6'-1 7/8"
10 5/8"
P3
PS6F3
P8
F3
PS6
F3
FS3
FS3
F3
FS3
FS3
F3
F2
P3
F2
PS3
TLT./SHWR
D308A
TLT./SHWR
D306A P3
"PS3
P3
PS3
2'-9 7/8"
3'-2 1/4"
AI501
AI501
E
D308A D306A
1/8"
3/8" 3/8"
3/8"
3/8"
5/8"
1/8"
5/8" 3/8"
3/8"
3/8"
1/8"
3/8"
1/8"
1/8"
3/8"
3/8"
3/8"
3/8"
3/8"
5/8"3/8"1/8"5/8"
3/8"
3/8"
D310A
/8
/8
/4
/4
/4
3'-5 3/8" 2'-10 1/4" 10 1/8"
11 7/8"
6'-1 7/8"
P3
PS6 F2 P6
F3
F3
FS3
PS3
FS3
PS3
F2 F2 F2
TLT./SHWR
D310A P3
D310A
1/8"
3/8"
3/8"
3/8"
1/8"
3/8"
3/8"
3/8"
3/8"
3/8"
1/8"
5/8"
5/8"
C
3/8"
3/8"
3/8"
D312A
3/8"
1/8"
5/8"
1/8"5/8"
1/8"
3/8"
3/8"
3/8"
3/8"
C
" 3
/4 " 1
/8
/4
/8
3'-5 3/8" 2'-9 1/8" 10"
10 5/8"
6'-1 7/8"
D312A
P3
PS6
F3
P6
F3
FS3
PS3
F2 F2
TLT./SHWR
D312A
P3
PS3
FS3
AI501
2'-11 7/8"
B
7.3
/8
/8
/4
/8
/4
/4
/8
C
D
D
A
D
A
D321
1'-11 3/4" 4'-4"
4 1/4"
4'-4"
/8
/8
/8
/2
2'-5" 4'-4" 3'-9 1/2"
PS3
P8F3
PS3
FS3
F0
FS3
PS3
PS3
PS6
FS3
FS3
F3
P3
P3 P3
P3TLT./SHWR
D320A
TLT./SHWR
D321A
P3
P3
F3
F3
F3
PS6
P3
2' - 6"
4' - 0"
F3
/4
10.44 5.12
8.04A
8.04A
B
7.3
D320A
D321A
3/8"
3/8"
1"
1/8"
1"
3/8"
3/8"
1/8"
3/8"
3/8"
1/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
5/8"
1/8"
5/8"
3/8" 3/8"
1/8"
1/8"
3/8"
B
8.2
/8
/8
/8
/8
1'-3" 3 3/8"
5 1/4"
8'-6 1/4"
D321
D
A
D322
/8
/8
2'-1 1/4" 4'-4"
1'-1 1/2"
2'-11 1/8"
P8PS3
FS3
F3
PS6
P3
F2
FS3
PS3
TLT./SHWR
D322A
F2
F3
P3
P3 2' - 6" 8.04A
B
8.2
D322A
5/8"
1/8"
3/8"
5/8"
3/8"
3/8"
3/8" 1/8"
3/8"
3/8"
3/8"
3/8"
1/8"
3/8"
B
9.1
/2
/8
/4
/4
/4
/4
/8
D324
D324A
D
A
D323
/8
/8
PS3
7'-6 3/8" 3'-5 3/8"
9 1/8" 1'-9 3/8" 4'-4" 3'-4"
PS3
F2
P8
PS3
PS3
F3
P3
TLT./SHWR
D324A
PT TLT.
D323A
PS3
AI706
32 30
AI70637
F3
P3
FS3
9 1/8"
6' - 0 1/2" 3' - 10 1/2"
PS6
PS6
P3
F2
PS3
FS3
/8
B
9.1
D324A
D323A
1/8"
3/8"
3/8"
5/8"
3/8"
3/8"
5/8"
5/8"
5/8"
5/8"
5/8"
1/8"
5/8"
3/8"
3/8"
3/8"
3/8"
1/8"
1/8"
3/8"
3/8"
3/8"
3/8"
1/8"
5/8"
3/8"
5/8"
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE403
ENLARGED PLANS - PATIENT TOILETS
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
1/4" = 1'-0"
ENLARGED - A315A TLT.
1/4" = 1'-0"
A315A TLT. - SLOPED FLOOR
1/4" = 1'-0"
ENLARGED - A314A TLT.
1/4" = 1'-0"
A314A TLT. - SLOPED FLOOR
1/4" = 1'-0"
ENLARGED - A313A TLT.
KEYNOTES
KEY VALUE KEYNOTE TEXT
5.12 3'-6" PARTIAL HEIGHT WALL
5.54 FLOOR EXPANSION JOINT ASSEMBLY, REF. SPEC
5.58 WALL EXPANSION JOINT ASSEMBLY, REF. SPEC
8.04A 16"X16" NON-RATED PLUMBING ACCESS PANEL
8.04B 12"X12" NON-RATED PLUMBING ACCESS PANEL
10.44 FIRE EXTINGUISHER CABINET
1/4" = 1'-0"
A313A TLT. - SLOPED FLOOR
1/4" = 1'-0"
ENLARGED - D304A TLT.
1/4" = 1'-0"
D304A TLT. - SLOPED FLOOR
1/4" = 1'-0"
ENLARGED - D306A & A308A TLT.
1/4" = 1'-0"
D306A & A308A TLT. - SLOPED FLOOR
1/4" = 1'-0"
ENLARGED - D310A TLT.
1/4" = 1'-0"
D310A TLT. - SLOPED FLOOR
1/4" = 1'-0"
D312A TLT. - SLOPED FLOOR
1/4" = 1'-0"
ENLARGED - D312A TLT.
1/4" = 1'-0"
ENLARGED - D320A & D321A TLT.
1/4" = 1'-0"
D320A & D321A TLT. - SLOPED FLOOR
1/4" = 1'-0"
ENLARGED - D322A TLT.
1/4" = 1'-0"
D322A TLT. - SLOPED FLOOR
1/4" = 1'-0"
ENLARGED - D323A & D324A TLT.
1/4" = 1'-0"
D323A & D324A TLT. - SLOPED FLOOR
A. REF. SPECIFICATION SECTION 13 05 41 "SEISMIC RESTRAINT REQUIREMENTS FOR NON-
STRUCTURAL COMPONENTS" FOR BRACING REQUIREMENTS FOR CEILINGS AND LIGHTING
FIXTURES
GENERAL RCP NOTES
TLT./SHWR
A313A
8' - 10"
AE501
5' - 6"
11.73
8' - 10"5' - 6"7' - 2"
TLT./SHWR
A314A
AE501
AE501
11.73
TLT./SHWR
A315A
8' - 10"
5' - 6"
7'
2"
AE501
AE501
11.73
TLT./SHWR
A316A
8' - 10"
5' - 6"7' - 2"
AE501
AE501
11.73
AE501
8' - 10"
5' - 6"7' - 2"
TLT./SHWR
A317A
AE501
AE501
11.73
TLT./SHWR
D319A
TLT./SHWR
A318A
8' - 10"
5' - 6"
8' - 10"
5' - 6"
AE501
AE501
11.73
11.73
AE501
TLT./SHWR
D320A
TLT./SHWR
D321A
11.73
11.73
8' - 10" 5' - 6"
7'
2"
8' - 10"
AE501
AE501
5' - 6"
AE501
TLT./SHWR
D322A
8' - 10"
5' - 6" 7' - 2"
AE501
AE501
11.73 PT TLT.
D323A
TLT./SHWR
D324A
11.73
11.73
8' - 10"
5' - 6"
8' - 10"
5' - 6"
7' - 4"
AE501
AE501
AE501
TLT./SHWR
A311A
8' - 10"
5' - 6"
AE501
11.73
TLT./SHWR
A309A
TLT./SHWR
A307A 11.73
11.73
AE501
AE501
8' - 10"
8' - 10"
5' - 6" 5' - 6"
7' - 4"7' - 4"
AE501
TLT./SHWR
A305A
NURSE
A328
8' - 10"
5' - 6"
AE501
AE501
11.73
AE501
5.55
TLT./SHWR
D312A
11.73
8' - 10"
7' - 4"
5' - 6"
AE501
AE501
TLT./SHWR
D310A
/8
11.73
AE501
5' - 6"
8' - 10"
/4
TLT./SHWR
D306A TLT./SHWR
D308A
8' - 10"
8' - 10"
5' - 6" 5' - 6"
7' - 4" 7' - 4"
AE501
AE501
AE501
________ 11.73
11.73
TLT./SHWR
D304A
11.73
8' - 10"
5' - 6"
7' - 4"
7' - 0"
AE501
AE501
TLT./SHWR
A302A
TLT./SHWR
A303A
11.73
11.73
8' - 10"
7' - 4"
7' - 4"
7' - 4"
8' - 10"
5' - 6"
5' - 6"
AE501
AE501
AE501
AE501
AE501
TLT./SHWR
A301A
AE501
8' - 10"
5' - 6"
11.73
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE410
ENLARGED RCP - PATIENT TOILETS
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
KEYNOTES
KEY VALUE KEYNOTE TEXT
5.55 CEILING EXPANSION JOINT ASSEMBLY, REF. SPEC
11.73 CEILING MOUNTED PATIENT LIFT SYSTEM1/4" = 1'-0"
ENLARGED RCP - A313A TLT.
1/4" = 1'-0"
ENLARGED RCP - A314A TLT.
1/4" = 1'-0"
ENLARGED RCP - A315A TLT.
1/4" = 1'-0"
ENLARGED RCP - A316A TLT.
1/4" = 1'-0"
ENLARGED RCP - A317A TLT.
1/4" = 1'-0"
ENLARGED RCP - A318A & D319A TLT.
1/4" = 1'-0"
ENLARGED RCP - D320A & D321A TLT.
1/4" = 1'-0"
ENLARGED RCP - D322A TLT.
1/4" = 1'-0"
ENLARGED RCP - D323A & D324A TLT.
1/4" = 1'-0"
ENLARGED RCP - A311A TLT.
1/4" = 1'-0"
ENLARGED RCP - A307A & A309A TLT.
1/4" = 1'-0"
ENLARGED RCP - A305A TLT.
1/4" = 1'-0"
ENLARGED RCP - D312A TLT.
1/4" = 1'-0"
ENLARGED RCP - D310A TLT.
1/4" = 1'-0"
ENLARGED RCP - D306A & D308A TLT.
1/4" = 1'-0"
ENLARGED RCP - D304A TLT.
1/4" = 1'-0"
ENLARGED RCP - A302A & A303A TLT.
1/4" = 1'-0"
ENLARGED RCP - A301A TLT.
VARIES REF.
CEILING PLAN
SUSPENDED ACOUST. CLG.
SYSTEM - REF. PLANS
VARIES REF.
CEILING PLAN
VARIES REF.
CEILING PLAN
3 5/8" MTL. STUD FRAMING
@ 16" O.C. MIN. UNLESS
NOTED OTHERWISE
SUSPENDED ACOUST. CLG.
SYSTEM - REF. PLANS
5/8" GYP. BD. BULKHEAD
ON 3 5/8" MTL. STUD
FRAMING @ 16" O.C.
M
IN
VARIES REF.
CEILING PLAN
GYP. BD. ON MTL. STUDS -
REF. PART. SCHED.
GYP. BD. SOFFIT ON
3 5/8" MTL. STUD
FRAMING @ 16" O.C.
SUSPENDED ACOUST. CLG.
SYSTEM - REF. PLANS
WHEN SOFFIT OCCURS AT
MILLWORK VERIFY DEPTH WITH
MILLWORK DETAIL
REF. PLAN
3 5/8" MTL. STUD FRAMING
@ 16" O.C. MIN. UNLESS
NOTED OTHERWISE
VARIES REF.
CEILING PLAN
GYP. BD. TO CONT. UP
TO DECK @ RATED &
SOUND PARTITIONS -
REF. PART. SCHED.
5/8" GYPSUM
WALLBOARD
BATT INSULATION
SEALANT
SEALANT
MTL STUD FRAMING, SEE
PLAN FOR WALL TYPE
STEEL STUD
5/8" GYPSUM
WALLBOARD
STEEL STUD
FEC CABINET
VARIES REF.
CEILING PLAN
GYP. BD. ON MTL. STUDS -
REF. PART. SCHED.
GYP. BD. SOFFIT ON
3 5/8" MTL. STUD
FRAMING @ 16" O.C.
WHEN SOFFIT OCCURS AT
MILLWORK VERIFY DEPTH WITH
MILLWORK DETAIL
REF. PLAN
3 5/8" MTL. STUD FRAMING
@ 16" O.C. MIN. UNLESS
NOTED OTHERWISE
VARIES REF.
CEILING PLAN
GYP. BD. TO CONT. UP
TO DECK @ RATED &
SOUND PARTITIONS -
REF. PART. SCHED.
GYP. BD. SOFFIT ON
3 5/8" MTL. STUD
FRAMING @ 16" O.C.
REF. PLAN
3 5/8" MTL. STUD CROSS
BRACING @ 4'-0" O.C.
SUSP. ACOUSTICAL CLG.
SYSTEM - REF. PLANS
VARIES REF.
CEILING PLAN
VARIES REF.
CEILING PLAN
SUSP. ACOUSTICAL CLG.
SYSTEM - REF. PLANS
VARIES REF.
CEILING PLAN
VARIES REF.
CEILING PLAN
M
IN
3 5/8" MTL. STUD FRAMING @ 16" O.C.
MIN. UNLESS NOTED OTHERWISE
5/8" GYP. BD. SOFFIT ON 3
5/8" MTL. STUD FRAMING
@ 16" O.C.
3 5/8" MTL. STUD CROSS
BRACING @ 4'-0" O.C.
3 5/8" MTL. STUD FRAMING
@ 16" O.C. MIN. UNLESS
NOTED OTHERWISE
REF. PLAN
M
IN
REF. PLAN
3RD LEVEL
26' - 5 1/4"
1 1/2" SOLID SURFACE SHELF
W/ EASED EDGE
(4) 3/8" ANCHOR BOLTS
UP-SWING GRAB BAR
WALL TILE
5/8" G.W.B
3 5/8" MTL. STUD FRAMING
@ 16" O.C.
TS 6x2x1/4" WELDED TO BOT
PLATE W/ 3/16" WELD
12"x4"x1/4" STL PLATE
5/8" EXP. BOLTS FOR CONC.
REF.
CEILING PLAN
TILE, REF. INTERIOR
ELEVATIONS & FINISH PLANS
12"x4"x1/4" STL PLATE
TS 6x2x1/4" WELDED TO
BOT PLATE W/ 3/16" WELD
5/8" EXP. BOLTS FOR CONC.
WALL TILE
MOUNTING BRACKET
UP-SWING GRAB BAR
GRAB BAR
5/8" G.W.B
SUPPORT MTL STUD
FASTEN AT BOTH ENDS W/
MIN. 4 TAPPING SCREWS
A. REF. SPECIFICATION SECTION 13 05 41 "SEISMIC RESTRAINT REQUIREMENTS FOR NON-
STRUCTURAL COMPONENTS" FOR BRACING REQUIREMENTS FOR CEILINGS AND LIGHTING
FIXTURES
GENERAL RCP NOTES
VARIES REF.
CEILING PLAN
GYP. BD. ON MTL. STUDS -
REF. PART. SCHED.
GYP. BD. SOFFIT ON
3 5/8" MTL. STUD
FRAMING @ 16" O.C.
SUSPENDED ACOUST. CLG.
SYSTEM - REF. PLANS
WHEN SOFFIT OCCURS AT
MILLWORK VERIFY DEPTH WITH
MILLWORK DETAIL
REF. PLAN
3 5/8" MTL. STUD FRAMING
@ 16" O.C. MIN. UNLESS
NOTED OTHERWISE
VARIES REF.
CEILING PLAN
GYP. BD. TO CONT. UP
TO DECK @ RATED &
SOUND PARTITIONS -
REF. PART. SCHED.
ANCHOR PER
SUPPLIER TYP.
4 5/8"
3 1/8"
2"
1 5/16"
/8
2 HR FIRESTOP/
EXPANSION JOINT,
REPLACE ANY EXISTING
FLOOR EXPANSION JOINT
ASSEMBLY, REF. SPEC
FLOOR DECK. REF. STRUCT.
FINISH FLOOR, REF. INTERIOR
2"1 1/16" 1 1/16"
1 5/8"
4 1/8" TAPE/ FEATHER
IN FIELD
ANCHOR PER
SUPPLIER TYP.
5/8" GYPSUM BOARD, TYPE
"X"
5/8" GYPSUM BOARD, TYPE
"X"
SEE PLAN FOR
WALL TYPE
EXPANSION JOINT COVER,
REF. SPEC
2"1 1/16" 1 1/16"
1 5/8"
4 1/8" TAPE/ FEATHER
IN FIELD
ANCHOR PER
SUPPLIER TYP.
5/8" GYPSUM BOARD, TYPE
"X"
5/8" GYPSUM BOARD, TYPE
"X"
SEE PLAN FOR
WALL TYPE
EXPANSION JOINT COVER,
REF. SPEC
2 7/8" 2" 2 7/8"
WALL TILE, REFERENCE
COLOR SCHEDULE KEY
ANCHOR PER
SUPPLIER TYP.
SEE PLAN FOR
WALL TYPE
7 3/4"
/2
2 3/8"
MOISTURE RESISTANT
GYPSUM BOARD, REF. SPEC
EXPANSION JOINT
COVER, REF. SPEC
EXPANSION JOINT
COVER, REF. SPEC
TAPE/ FEATHER IN FIELD
4TH LEVEL
39' - 1 1/4"
M
IN8
EXISTING ROOF ASSEMBLY
EXP. BOLTS FOR CONC.
STEEL TUBE POST, REF STRUCTURAL
NEW FULLY ADHERED EPDM
MEMBRANE, OVERLAPPING EXISTING
METAL GRATE TREADS
METAL STRINGER WELDED TO
STEEL POST
NEW TAPERED POLYISO
INSULATION
NEW 1/2" COVER BOARD
NEW VAPOR BARRIER
SEAMING/TERMINATION ADHESIVE
PER MEMBRANE SUPPLIER
1/4" CAP PLATE
REF. STRUCT.
METAL PIPE GUARDRAIL
/HANDRAIL
EQ EQ
T Y
P
1/2" 1
DOOR PANEL, REF. SECHDULE
DOOR THRESHOLD SET IN SEALANT
METAL GRATE LANDING
EXISTING WALL ASSEMBLY
PREFINISHED METAL FLASHING
METAL STRINGER WELDED TO
STEEL POST, REF. STRUCT.
1/4" CAP PLATE
REF. STRUCTURAL
REF. STRUCT. REF. STRUCTURAL
NEW FULLY ADHERED EPDM
MEMBRANE, OVERLAPPING EXISTING
BATT INSULATION
NEW EQUIPMENT
EXISTING ROOF STRUCTURE
WRAP EPDM OVER CURB TOP
SEAMING/TERMINATION ADHESIVE
PER MEMBRANE SUPPLIER
A B
O V
E C
O V
E R
B O
A R
D
M
IN
NEW VAPOR BARRIER
NEW EQUIPMENT CURB
3/4" PLYWOOD
6" METAL RUNNER CHANNEL
4TH LEVEL
39' - 1 1/4"
NEW FULLY ADHERED EPDM
MEMBRANE, OVERLAPPING EXISTING
BATT INSULATION
NEW EQUIPMENT
EXISTING ROOF STRUCTURE
WRAP EPDM OVER CURB TOP
SEAMING/TERMINATION ADHESIVE
PER MEMBRANE SUPPLIER
'-8
NEW VAPOR BARRIER
NEW EQUIPMENT CURB
3/4" PLYWOOD
6" METAL RUNNER CHANNEL
4TH LEVEL
39' - 1 1/4"
EXISTING FLOOR
ASSEMBLY
EXP. BOLTS FOR
CONC. REF. STRUCT.
METAL GRATE
LANDING AND TREADS
VARIES REF.
CEILING PLAN
SUSPENDED ACOUST. CLG.
SYSTEM - REF. PLANS
VARIES REF.
CEILING PLAN
4"
LED STRIP - REF. ELEC.
LED LENS - REF. ELEC.
5/8" GYP. BD ON SUSPENDED
DRYWALL CEILING SYSTEM.
2" AXIOM TRANSITIONS TRIM OR
EQUAL
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202054
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA 51101
712.252.4014
142 N. MOSLEY ST.
WICHITA, KANSAS 67202
316.262.2500
303 S. TOPEKA
WICHITA, KANSAS 67202
316.262.2691
AE501
DETAILS
RELOCATE MEDICAL WARD
FOR PATIENT PRIVACY
800 HOSPITAL DRIVE COLUMBIA, MO 65201
07-26-2021
589A4-21-100
FINAL CONSTRUCTION DOCUMENTS
AuthorChecker
1 1/2" = 1'-0"
DETAIL @ AT/GYP/AT BULKHEAD
1 1/2" = 1'-0"
DETAIL @ GYP SOFFIT & AT
3/4" = 1'-0"
SECTION @ FE CABINET
1 1/2" = 1'-0"
TYP GYP SOFFIT @ GYP CEILING
1 1/2" = 1'-0"
SOFFIT DETAIL
1 1/2" = 1'-0"
UP-SWING GRAB BAR @ NICHE & SHELF
1 1/2" = 1'-0"
UP-SWING GRAB BAR
1 1/2" = 1'-0"
DETAIL @ GYP SOFFIT & AT OFFSET
6" = 1'-0"
EXPANSION JOINT - INT FLOOR
6" = 1'-0"
EXPANSION JOINT - INT GYP CEILING
6" = 1'-0"
EXPANSION JOINT - INT WALL
6" = 1'-0"
EXPANSION JOINT - INT WALL TILE
1 1/2" = 1'-0"
STAIRS TO ROOF ATTACHMENT
1 1/2" = 1'-0"
EXT. DOOR THRESHOLD @ ROOF ACCESS
1 1/2" = 1'-0"
DETAIL @ FLAT ROOF - MECH. CURB
1 1/2" = 1'-0"
DETAIL @ FLAT ROOF - EXTENTED MECH. CURB
1 1/2" = 1'-0"
STAIRS TO FLOOR ATTACHMENT
1 1/2" = 1'-0"
DETAIL @ CORRIDOR CEILING BUMP UPS
A C E
R E
F S
C H
E D
REF. SCHED.
DB
ALUM. SLIDING DOOR, MANUAL OPERATION TYP.
T
R E
F S
C H
E D
REF. SCHED.
R E
F S
C H
E D
REF. SCHED.
R E
F S
C H
E D
REF. SCHED.
REF. SCHED.
9"
4"
100 SQ. IN. @
FIRE RATED
OPENINGS
GLASS SHALL
BE TYPE MG #1
OR FR #1 AT
RATED DOORS -
REF. SCHED.
STAINLESS STEEL
PROTECTION
PLATE?
8' - 2"
R E
F S
C H
E D
T T
T T
C1
R E
F S
C H
E D
REF. SCHED.
T
9" 9" GLASS SHALL
BE TYPE MG #1
OR FR #1 AT
RATED DOORS -
REF. SCHED.
INTEGRAL
BLINDS
-SEE SPEC
SECTION 088000
GLAZING
R E
F S
C H
E D
REF. SCHED.
REF. SCHED.
T
9"
9"
INTEGRAL
BLINDS
-SEE SPEC
SECTION 088000
GLAZING
AS602
D1
- ALL DOOR FRAME THROAT SIZES TO BE VERIFIED BY CONTRACTOR.
- ALL DOORS TO HAVE 4 HINGES
GENERAL NOTES:
1 2
R E
F S
C H
E D
2"
SCHED.
REF. 2"
SINGLE DOOR
R E
F S
C H
E D
2"
SCHED.
REF.
SCHED.
REF. 2"
DBL. DOOR
AS602
AS602
AS602
AS602
AS602
AS602
SIM
/2
R E
F S
C H
E D
2"
SCHED.
REF. SCHED.
REF. 2"
DBL. UNEVEN
PATIENT TLT. DOOR
EQ. 3" EQ.
NOTCH FOR PATIENT LIFT
TRACK. NOTCH TO HAVE
WELDED ENCLOSURE
AROUND IT'S PERIMETER.
VERIFY SIZE AND
LOCATION W/ LIFT SYSTEM
VENDOR PRIOR TO
FABRICATION11"
LIFT…