This document contains technical specifications for removable bollards. The specifications call out removable post barricades without concrete filling, with strap and bolt details shown. Type A barricades are specified as 4"x2' pipe sleeves or 1'6" tall posts, while Type B are 6"x3' sleeves or 2'6" tall posts. Footing dimensions and utility concrete are referenced to VA specifications 32 02 23-04 and 32 05 23-06. The related federal contract opportunity is a solicitation from the Department of Veterans Affairs seeking bids for removable bollards as part of project #520-22-122 to correct buildings at the Biloxi MATOC facility. The specifications and solicitation thus concern removable bollard installation for VA facility security upgrades.

View the file

Other files

File Type Posted
36C25622R0030 055000 Metal Fabrication.docx DOCX document
36C25622R0030 0006.docx DOCX document
36C25622R0030 262921 Enclosed Switches and Circuit Breakers.docx DOCX document
36C25622R0030 0005.docx DOCX document
36C25622R0030 Spec 013323 v2.doc DOC document
36C25622R0030 099100 PAINTING.doc DOC document
36C25622R0030 133419 Pre-Engineered Metal Bldg Systems.doc DOC document
36C25622R0030 262416 Electrical Panelboards.docx DOCX document
36C25622R0030 Main Elec Panel Schedule.pdf PDF
36C25622R0030 RFI Register 10182022.docx DOCX document
36C25622R0030 263213 Engine Generators v2.docx DOCX document
36C25622R0030 Site Utility Map.pdf PDF
36C25622R0030 211313 Wet Pipe Sprinkler System.docx DOCX document
36C25622R0030 0004.docx DOCX document
36C25622R0030 081113 Hollow Metal Doors and Frames.doc DOC document
36C25622R0030 087100 DOOR HARDWARE.doc DOC document
36C25622R0030 SD320523 04 Concrete Post Bollards.pdf PDF
36C25622R0030 34751313 Vehicle Barrier.docx DOCX document
36C25622R0030 Bldg 17 Details Section.pdf PDF
36C25622R0030 B17 Floor Plan.pdf PDF
36C25622R0030 SD320523 06 Removable Bollard 2 (Strap Detail).pdf PDF
36C25622R0030 0003.docx DOCX document
36C25622R0030 0002.docx DOCX document
36C25622R0030 FCA Corrections Bldg 17 - Full Set v2.pdf PDF
S04 Site Visit Attendance Sheet (08.30.2022).pdf PDF
36C25622R0030 0001.docx DOCX document
36C25622R0030 EXHIBIT I-Financial Disclosure.docx DOCX document
36C25622R0030 SOW FCA Corrections Bldg 17 (Revised v2).pdf PDF
36C25622R0030 Spec 013323.doc DOC document
36C25622R0030 Drawings-FCA Corrections BLDG 17 .pdf PDF
36C25622R0030 Spec 220511 .doc DOC document
36C25622R0030 EXHIBIT F-RFI Form .docx DOCX document
36C25622R0030 Spec 260511 .doc DOC document
36C25622R0030 EXHIBIT H-Contractor Information.docx DOCX document
36C25622R0030 Spec 062000 .doc DOC document
36C25622R0030 WD MS20220060 Mod 1 02252022 (Harrision Heavy) .docx DOCX document
36C25622R0030 Spec 024100 .doc DOC document
36C25622R0030 Spec 017419 .doc DOC document
36C25622R0030 EXHIBIT E-Surety Form .docx DOCX document
36C25622R0030 EXHIBIT A-Performance Relevancy Survey .docx DOCX document
36C25622R0030 EXHIBIT D-Contractor Evaluation Form Construction Safety .docx DOCX document
36C25622R0030 VHA Supplemental Contract Requirements for Combatting COVID-19.docx DOCX document
36C25622R0030 WD MS20220050 Mod 2 02252022 (Harrision Building) .docx DOCX document
36C25622R0030 EXHIBIT C-Subcontractor Information and Consent Form .docx DOCX document
36C25622R0030 Spec 078400 .doc DOC document
36C25622R0030 EXHIBIT B-Past and Present Performance Questionnaire.docx DOCX document
36C25622R0030 WD MS20220133 Mod 1 02252022 (Harrision Highway) .docx DOCX document
36C25622R0030 Spec 013526 v2 (updated 071322).docx DOCX document
36C25622R0030 Spec 262726 v2 (updated (071322).doc DOC document
36C25622R0030 Seed ICRA .pdf PDF
Show 40 more

Latest 50 of 54 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REMOVABLE POST BARRICADE

NTS

NOTES:

1. REMOVABLE POST BARRICADE SHALL NOT BE CONCRETE FILLED.

2. HAND TIGHTEN BOLT & NUT USING WASHERS EACH SIDE OF

STRAPS. CUT BOLT APPROX. 1/8" [6mm] FROM FACE OF NUT

& PEEN EXPOSED END OF BOLT.

3. REFER TO VA STANDAD DETAIL 32 02 23-04 "CONCRETE POST

BARRICADES" FOR POST DETAILS.

STANDARD PIPE SLEEVE

4"∅x2' [100x610mm] (TYPE "A") 6"∅x3' [150x915mm] (TYPE "B")

REFER TO VA STANDAD DETAIL

32 02 23-04 "CONCRETE

POST BARRICADES" FOR

FOOTING DIMENSIONS

UTILITY CONCRETE PER

VA SPECIFICATIONS

3 1/2"x1 1/2"x1/4" [90x40x6mm]

1/2"x1" HEX BOLT [13x25mm] 2 WASHERS, NUT.

VA STANDARD DETAIL

32 05 23-06 "REMOVABLE

POST BARRICADE - STRAP

DETAIL" FOR ADDITIONAL

INFORMATION

2"x1 1/2"x1/4" STRAP [50x40x6mm]

T Y P E

B m m

T Y P E

A m m

T Y P E

B m m

T Y P E

A m m

SCALE :

CAD DETAIL NO.: DATE ISSUED:

DETAIL TITLE / REMOVABLE POST BARRICADE

SD320523-05.DWGDECEMBER 2008

NONE

8.5x11

File details come from the government source that posted it. Updated .