This specification covers painting requirements for a federal project. It requires field painting of various surfaces including wood, ferrous metals, galvanized metal, masonry, concrete, and gypsum board. Specific paints are identified by their Master Painters Institute numbers to be applied in a multi-coat system with prime, body, and finish coats. Requirements include surface preparation, application methods, colors, protection during work, and cleanup. Health, safety and environmental regulations for paint materials are also outlined.
View the file
Other files
Show 40 more
Latest 50 of 54 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 09 91 00
PAINTING
PART 1-GENERAL
1.1 DESCRIPTION
A.
Section specifies field painting.
B.
Section specifies prime coats which may be applied in shop under other sections.
C.
Painting includes shellacs, stains, varnishes, coatings specified, and striping or markers and identity markings.
1.2 RELATED WORK
A.
Shop prime painting of steel and ferrous metals: Division 08 - OPENINGS, Division 22 - PLUMBING, Division 23 – HVAC, Division 26 - ELECTRICAL B.
Type of Finish, Color, and Gloss Level of Finish Coat: To be selected by COR.
1.3 SUBMITTALS
A.
Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.
B.
Manufacturer's Literature and Data:
Before work is started, or sample panels are prepared, submit manufacturer's literature, the current Master Painters Institute (MPI) "Approved Product List" indicating brand label, product name and product code as of the date of contract award, will be used to determine compliance with the submittal requirements of this specification. The Contractor may choose to use subsequent MPI "Approved Product List", however, only one list may be used for the entire contract and each coating system is to be from a single manufacturer. All coats on a particular substrate must be from a single manufacturer. No variation from the MPI "Approved Product List" where applicable is acceptable.
C.
Manufacturers' Certificates indicating compliance with specified requirements:
1.
Manufacturer's paint substituted for Federal Specification paints meets or exceeds performance of paint specified.
2.
High temperature aluminum paint.
3.
Epoxy coating.
4.
Intumescent clear coating or fire retardant paint.
5.
Plastic floor coating.
1.4 DELIVERY AND STORAGE
A.
Deliver materials to site in manufacturer's sealed container marked to show following:
1.
Name of manufacturer.
2.
Product type.
3.
Batch number.
4.
Instructions for use.
5.
Safety precautions.
B.
Maintain space for storage, and handling of painting materials and equipment in a neat and orderly condition to prevent spontaneous combustion from occurring or igniting adjacent items.
C.
Store materials at site at least 24 hours before using, at a temperature between 18 and 30 degrees C (65 and 85 degrees F).
1.5 APPLICABLE PUBLICATIONS
A.
Publications listed below form a part of this specification to the extent referenced. Publications are referenced in the text by basic designation only.
B.
American Conference of Governmental Industrial Hygienists (ACGIH):
ACGIH TLV-BKLT-1992
Threshold Limit Values (TLV) for Chemical Substances and Physical Agents and Biological Exposure Indices (BEIs)
ACGIH TLV-DOC
Documentation of Threshold Limit Values and Biological Exposure Indices, (Sixth Edition)
C.
American National Standards Institute (ANSI):
A13.1-96 Scheme for the Identification of Piping Systems
D.
American Society for Testing and Materials (ASTM):
D260-86..........Boiled Linseed Oil
E.
Commercial Item Description (CID):
A-A-1555 Water Paint, Powder (Cementitious, White and Colors) (WPC) (cancelled)
A-A-3120 Paint, For Swimming Pools (RF) (cancelled)
F.
Federal Specifications (Fed Spec):
TT-P-1411A
Paint, Copolymer-Resin, Cementitious (For Waterproofing Concrete and Masonry Walls) (CEP)
G.
Master Painters Institute (MPI):
No. 1-06 Aluminum Paint (AP)
No. 4-06 Interior/ Exterior Latex Block Filler
No. 5-06 Exterior Alkyd Wood Primer
No. 7-06 Exterior Oil Wood Primer
No. 8-06 Exterior Alkyd, Flat MPI Gloss Level 1 (EO)
No. 9-06 Exterior Alkyd Enamel MPI Gloss Level 6 (EO)
No. 10-06 Exterior Latex, Flat (AE)
No. 11-06 Exterior Latex, Semi-Gloss (AE)
No. 18-06 Organic Zinc Rich Primer No. 22-06 Aluminum Paint, High Heat (up to 590% - 1100F) (HR)
No. 26-06 Cementitious Galvanized Metal Primer
No. 27-06 Exterior / Interior Alkyd Floor Enamel, Gloss (FE)
No. 31-06 Polyurethane, Moisture Cured, Clear Gloss (PV)
No. 36-06 Knot Sealer
No. 43-06 Interior Satin Latex, MPI Gloss Level 4 No. 44-06 Interior Low Sheen Latex, MPI Gloss Level 2 No. 45-06 Interior Primer Sealer
No. 46-06 Interior Enamel Undercoat
No. 47-06 Interior Alkyd, Semi-Gloss, MPI Gloss Level 5 (AK)
No. 48-06 Interior Alkyd, Gloss, MPI Gloss Level 6 (AK)
No. 49-06 Interior Alkyd, Flat, MPI Gloss Level 1 (AK)
No. 50-06 Interior Latex Primer Sealer
No. 51-06 Interior Alkyd, Eggshell, MPI Gloss Level 3 No. 52-06 Interior Latex, MPI Gloss Level 3 (LE)
No. 53-06 Interior Latex, Flat, MPI Gloss Level 1 (LE)
No. 54-06 Interior Latex, Semi-Gloss, MPI Gloss Level 5 (LE)
No. 59-06 Interior/Exterior Alkyd Porch & Floor Enamel, Low Gloss (FE)
No. 60-06 Interior/Exterior Latex Porch & Floor Paint, Low Gloss
No. 66-06 Interior Alkyd Fire Retardant, Clear Top-Coat (ULC Approved) (FC)
No. 67-06 Interior Latex Fire Retardant, Top-Coat (ULC Approved) (FR)
No. 68-06 Interior/ Exterior Latex Porch & Floor Paint, Gloss
No. 71-06 Polyurethane, Moisture Cured, Clear, Flat (PV) No. 74-06 Interior Alkyd Varnish, Semi-Gloss
No. 77-06 Epoxy Cold Cured, Gloss (EC)
No. 79-06 Marine Alkyd Metal Primer
No. 90-06 Interior Wood Stain, Semi-Transparent (WS)
No. 91-06 Wood Filler Paste
No. 94-06 Exterior Alkyd, Semi-Gloss (EO)
No. 95-06 Fast Drying Metal Primer
No. 98-06 High Build Epoxy Coating
No. 101-06 Epoxy Anti-Corrosive Metal Primer No. 108-06 High Build Epoxy Coating, Low Gloss (EC) No. 114-06 Interior Latex, Gloss (LE) and (LG)
No. 119-06 Exterior Latex, High Gloss (acrylic) (AE)
No. 135-06 Non-Cementitious Galvanized Primer
No. 138-06 Interior High Performance Latex, MPI Gloss Level 2 (LF)
No. 139-06 Interior High Performance Latex, MPI Gloss Level 3 (LL)
No. 140-06 Interior High Performance Latex, MPI Gloss Level 4
No. 141-06 Interior High Performance Latex (SG) MPI Gloss Level 5
H.
Steel Structures Painting Council (SSPC):
SSPC SP 1-00 (R2004)
Solvent Cleaning
SSPC SP 2-00 (R2004)
Hand Tool Cleaning
SSPC SP 3-00 (R2004)
Power Tool Cleaning
PART 2 - PRODUCTS
2.1 MATERIALS
A.
Cementitious Paint (CEP): TT-P-1411A [Paint, Copolymer-Resin, Cementitious (CEP)], Type 1 for exterior use, Type II for interior use.
B.
Plastic Tape:
1.
Pigmented vinyl plastic film in colors as specified in Section 09 06 00, SCHEDULE FOR FINISHES or specified.
2.
Pressure sensitive adhesive back.
3.
Widths as shown.
C.
Identity markers options:
1.
Pressure sensitive vinyl markers.
2.
Snap-on coil plastic markers.
D.
Interior/Exterior Latex Block Filler: MPI 4.
E.
Interior Satin Latex: MPI 43.
F.
Interior Low Sheen Latex: MPI 44.
G.
Interior Primer Sealer: MPI 45.
H.
Interior Latex, MPI Gloss Level 3 (LE): MPI 52.
I.
Interior Latex, Flat, MPI Gloss Level 1 (LE): MPI 53.
J.
Interior Latex, Semi-Gloss, MPI Gloss Level 5 (LE): MPI 54.
K.
Interior High Performance Latex, MPI Gloss Level 2(LF): MPI 138.
L.
Interior High Performance Latex, MPI Gloss Level 3 (LL): MPI 139.
M.
Interior High Performance Latex, MPI Gloss Level 4: MPI 140.
N.
Interior High Performance Latex (SG), MPI Gloss Level 5: MPI 141.
2.2 PAINT PROPERTIES
A.
Use ready-mixed (including colors), except two component epoxies, polyurethanes, polyesters, paints having metallic powders packaged separately and paints requiring specified additives.
B.
Where no requirements are given in the referenced specifications for primers, use primers with pigment and vehicle, compatible with substrate and finish coats specified.
2.3 REGULATORY REQUIREMENTS/quality assurance
A.
Paint materials shall conform to the restrictions of the local Environmental and Toxic Control jurisdiction.
1.
Volatile Organic Compounds (VOC): VOC content of paint materials shall not exceed 10g/l for interior latex paints/primers and 50g/l for exterior latex paints and primers.
2.
Lead-Base Paint:
a.
Comply with Section 410 of the Lead-Based Paint Poisoning Prevention Act, as amended, and with implementing regulations promulgated by Secretary of Housing and Urban Development.
b.
Regulations concerning prohibition against use of lead-based paint in federal and federally assisted construction, or rehabilitation of residential structures are set forth in Subpart F, Title 24, Code of Federal Regulations, Department of Housing and Urban Development.
c.
For lead-paint removal, see Section 02 83 33.13, LEAD-BASED PAINT REMOVAL AND DISPOSAL.
3.
Asbestos: Materials shall not contain asbestos.
4.
Chromate, Cadmium, Mercury, and Silica: Materials shall not contain zinc-chromate, strontium-chromate, Cadmium, mercury or mercury compounds or free crystalline silica.
5.
Human Carcinogens: Materials shall not contain any of the ACGIH-BKLT and ACGHI-DOC confirmed or suspected human carcinogens.
6.
Use high performance acrylic paints in place of alkyd paints, where possible.
7.
VOC content for solvent-based paints shall not exceed 250g/l and shall not be formulated with more than one percent aromatic hydro carbons by weight.
PART 3 - EXECUTION
3.1 JOB CONDITIONS
A.
Safety: Observe required safety regulations and manufacturer's warning and instructions for storage, handling and application of painting materials.
1.
Take necessary precautions to protect personnel and property from hazards due to falls, injuries, toxic fumes, fire, explosion, or other harm.
2.
Deposit soiled cleaning rags and waste materials in metal containers approved for that purpose. Dispose of such items off the site at end of each days work.
B.
Atmospheric and Surface Conditions:
1.
Do not apply coating when air or substrate conditions are:
a.
Less than 3 degrees C (5 degrees F) above dew point.
b.
Below 10 degrees C (50 degrees F) or over 35 degrees C (95 degrees F), unless specifically pre-approved by the Contracting Officer and the product manufacturer. Under no circumstances shall application conditions exceed manufacturer recommendations.
2.
Maintain interior temperatures until paint dries hard.
3.
Do no exterior painting when it is windy and dusty.
4.
Do not paint in direct sunlight or on surfaces that the sun will soon warm.
5.
Apply only on clean, dry and frost free surfaces except as follows:
a.
Apply water thinned acrylic and cementitious paints to damp (not wet) surfaces where allowed by manufacturer's printed instructions.
b.
Dampened with a fine mist of water on hot dry days concrete and masonry surfaces to which water thinned acrylic and cementitious paints are applied to prevent excessive suction and to cool surface.
6.
Varnishing:
a.
Apply in clean areas and in still air.
b.
Before varnishing vacuum and dust area.
c.
Immediately before varnishing wipe down surfaces with a tack rag.
3.2 inspection:
A. Examine the areas and conditions where painting and finishing are to be applied and correct any conditions detrimental to the proper and timely completion of the work. Do not proceed with the work until unsatisfactory conditions are corrected to permit proper installation of the work.
3.3 general workmanship requirements:
B. Application may be by brush or roller. Spray application only upon acceptance from the COR in writing.
C. Furnish to the COR a painting schedule indicating when the respective coats of paint for the various areas and surfaces will be completed. This schedule is to be kept current as the job progresses.
D. Protect work at all times. Protect all adjacent work and materials by suitable covering or other method during progress of work. Upon completion of the work, remove all paint and varnish spots from floors, glass and other surfaces. Remove from the premises all rubbish and accumulated materials of whatever nature not caused by others and leave work in a clean condition.
E. Remove and protect hardware, accessories, device plates, lighting fixtures, and factory finished work, and similar items, or provide in place protection. Upon completion of each space, carefully replace all removed items by workmen skilled in the trades involved.
F. When indicated to be painted, remove electrical panel box covers and doors before painting walls. Paint separately and re-install after all paint is dry.
G. Materials are to be applied under adequate illumination, evenly spread and flowed on smoothly to avoid runs, sags, holidays, brush marks, air bubbles and excessive roller stipple.
H. Apply materials with a coverage to hide substrate completely. When color, stain, dirt or undercoats show through final coat of paint, the surface is to be covered by additional coats until the paint film is of uniform finish, color, appearance and coverage, at no additional cost to the Government.
I. All coats are to be dry to manufacturer’s recommendations before applying succeeding coats.
J. All suction spots or “hot spots” in plaster after the application of the first coat are to be touched up before applying the second coat.
K. Do not apply paint behind frameless mirrors that use mastic for adhering to wall surface.
3.4 SURFACE PREPARATION
L. General:
1. The Contractor shall be held wholly responsible for the finished appearance and satisfactory completion of painting work. Properly prepare all surfaces to receive paint, which includes cleaning, sanding, and touching-up of all prime coats applied under other Sections of the work. Broom clean all spaces before painting is started. All surfaces to be painted or finished are to be completely dry, clean and smooth.
2. See other sections of specifications for specified surface conditions and prime coat.
3. Perform preparation and cleaning procedures in strict accordance with the paint manufacturer’s instructions and as herein specified, for each particular substrate condition.
4. Clean surfaces before applying paint or surface treatments with materials and methods compatible with substrate and specified finish. Remove any residue remaining from cleaning agents used. Do not use solvents, acid, or steam on concrete and masonry. Schedule the cleaning and painting so that dust and other contaminants from the cleaning process will not fall in wet, newly painted surfaces.
5. Maximum Moisture Content of Substrates: When measured with an electronic moisture meter as follows:
a. Concrete: 12 percent.
b. Fiber-Cement Board: 12 percent.
c. Masonry (Clay and CMU’s): 12 percent.
d. Wood: 15 percent.
e. Gypsum Board: 12 percent.
f. Plaster: 12 percent.
M. Wood:
1. Sand to a smooth even surface and then dust off.
2. Sand surfaces showing raised grain smooth between each coat.
3. Wipe surface with a tack rag prior to applying finish.
4. Surface painted with an opaque finish:
a. Coat knots, sap and pitch streaks with MPI 36 (Knot Sealer) before applying paint.
b. Apply two coats of MPI 36 (Knot Sealer) over large knots.
5. After application of prime or first coat of stain, fill cracks, nail and screw holes, depressions and similar defects with wood filler paste. Sand the surface to make smooth and finish flush with adjacent surface.
6. Before applying finish coat, reapply wood filler paste if required, and sand surface to remove surface blemishes. Finish flush with adjacent surfaces.
7. Fill open grained wood such as oak, walnut, ash and mahogany with MPI 91 (Wood Filler Paste), colored to match wood color.
a. Thin filler in accordance with manufacturer's instructions for application.
b. Remove excess filler, wipe as clean as possible, dry, and sand as specified.
N. Ferrous Metals:
1. Remove oil, grease, soil, drawing and cutting compounds, flux and other detrimental foreign matter in accordance with SSPC-SP 1 (Solvent Cleaning).
2. Remove loose mill scale, rust, and paint, by hand or power tool cleaning, as defined in SSPC-SP 2 (Hand Tool Cleaning) and SSPC-SP 3 (Power Tool Cleaning). Where high temperature aluminum paint is used, prepare surface in accordance with paint manufacturer's instructions.
3. Fill dents, holes and similar voids and depressions in flat exposed surfaces of hollow steel doors and frames, access panels, roll-up steel doors and similar items specified to have semi-gloss or gloss finish with TT-F-322D (Filler, Two-Component Type, For Dents, Small Holes and Blow-Holes). Finish flush with adjacent surfaces.
a. Fill flat head countersunk screws used for permanent anchors.
b. Do not fill screws of item intended for removal such as glazing beads.
4. Spot prime abraded and damaged areas in shop prime coat which expose bare metal with same type of paint used for prime coat. Feather edge of spot prime to produce smooth finish coat.
5. Spot prime abraded and damaged areas which expose bare metal of factory finished items with paint as recommended by manufacturer of item.
O. Zinc-Coated (Galvanized) Metal, Aluminum, Copper and Copper Alloys Surfaces Specified Painted:
1. Clean surfaces to remove grease, oil and other deterrents to paint adhesion in accordance with SSPC-SP 1 (Solvent Cleaning).
2. Spot coat abraded and damaged areas of zinc-coating which expose base metal on hot-dip zinc-coated items with MPI 18 (Organic Zinc Rich Coating). Prime or spot prime with MPI 134 (Waterborne Galvanized Primer) or MPI 135 (Non-Cementitious Galvanized Primer) depending on finish coat compatibility.
P. Masonry, Concrete, Cement Board, Cement Plaster and Stucco:
1. Clean and remove dust, dirt, oil, grease efflorescence, form release agents, laitance, and other deterrents to paint adhesion.
2. Use emulsion type cleaning agents to remove oil, grease, paint and similar products. Use of solvents, acid, or steam is not permitted.
3. Remove loose mortar in masonry work.
4. Replace mortar and fill open joints, holes, cracks and depressions with new mortar specified in Section 04 05 13, MASONRY MORTARING Section 04 05 16, MASONRY GROUTING. Do not fill weep holes. Finish to match adjacent surfaces.
5. Neutralize Concrete floors to be painted by washing with a solution of 1.4 Kg (3 pounds) of zinc sulfate crystals to 3.8 L (1 gallon) of water, allow to dry three (3) days and brush thoroughly free of crystals.
6. Repair broken and spalled concrete edges with concrete patching compound to match adjacent surfaces as specified in Division 03, CONCRETE Sections. Remove projections to level of adjacent surface by grinding or similar methods.
Q. Gypsum Plaster and Gypsum Board:
1. Remove efflorescence, loose and chalking plaster or finishing materials.
2. Remove dust, dirt, and other deterrents to paint adhesion.
3. Fill holes, cracks, and other depressions with CID-A-A-1272A finished flush with adjacent surface, with texture to match texture of adjacent surface. Patch holes over 25 mm (1-inch) in diameter as specified in Section for plaster or gypsum board.
3.5 PAINT PREPARATION
A.
Thoroughly mix painting materials to ensure uniformity of color, complete dispersion of pigment and uniform composition.
B.
Do not thin unless necessary for application and when finish paint is used for body and prime coats. Use materials and quantities for thinning as specified in manufacturer's printed instructions.
C.
Remove paint skins, then strain paint through commercial paint strainer to remove lumps and other particles.
D.
Mix two component and two part paint and those requiring additives in such a manner as to uniformly blend as specified in manufacturer's printed instructions unless specified otherwise.
E.
For tinting required to produce exact shades specified, use color pigment recommended by the paint manufacturer.
3.6 APPLICATION
A.
Start of surface preparation or painting will be construed as acceptance of the surface as satisfactory for the application of materials.
B.
Unless otherwise specified, apply paint in three coats; prime, body, and finish. When two coats applied to prime coat are the same, first coat applied over primer is body coat and second coat is finish coat.
C.
Apply each coat evenly and cover substrate completely.
D.
Allow not less than 48 hours between applications of succeeding coats, except as allowed by manufacturer's printed instructions, and approved by Project Engineer.
E.
Finish surfaces to show solid even color, free from runs, lumps, brushmarks, laps, holidays, or other defects.
F.
Apply by brush, roller or spray, except as otherwise specified.
G.
Do not spray paint in existing occupied spaces unless approved by Project Engineer, except in spaces sealed from existing occupied spaces.
1.
Apply painting materials specifically required by manufacturer to be applied by spraying.
2.
In areas, where paint is applied by spray, mask or enclose with polyethylene, or similar air tight material with edges and seams continuously sealed including items specified in WORK NOT PAINTED, motors, controls, telephone, and electrical equipment, fronts of sterilizes and other recessed equipment and similar prefinished items.
I.
Do not paint in closed position operable items such as access doors and panels, window sashes, overhead doors, and similar items except overhead roll-up doors and shutters.
3.7 PRIME PAINTING
A.
After surface preparation prime surfaces before application of body and finish coats, except as otherwise specified.
B.
Spot prime and apply body coat to damaged and abraded painted surfaces before applying succeeding coats.
C.
Additional field applied prime coats over shop or factory applied prime coats are not required except for exterior exposed steel apply an additional prime coat.
D.
Prime rebates for stop and face glazing of wood, and for face glazing of steel.
E.
Gypsum Board and Hardboard:
1.
Surfaces scheduled to have Interior Latex, Flat), MPI Gloss Level 1 LE)) MPI 52 (Interior Latex, MPI Gloss Level 3 (LE)) MPI 54 (Interior Latex, Semi-Gloss, MPI Gloss Level 5 (LE)) MPI 114 (Interior Latex, Gloss (LE) and (LG)) finish: Use MPI 10 Interior Latex, MPI Gloss Level 3 (LE)) MPI 52 (Interior Latex, MPI Gloss Level 3 (LE)) MPI 54 (Interior Latex, Semi-Gloss, MPI Gloss Level 5 (LE)) MPI 114 (Interior Latex, Gloss (LE) and (LG)) respectively.
2.
Primer: MPI 50(Interior Latex Primer Sealer) except use MPI 45 (Interior Primer Sealer) MPI 46 (Interior Enamel Undercoat) in shower and bathrooms.
3.
Surfaces scheduled to receive vinyl coated fabric wallcovering:
Use MPI 45 (Interior Primer Sealer) MPI 46 (Interior Enamel Undercoat).
4.
Use MPI 101 (Cold Curing Epoxy Primer) for surfaces scheduled to receive MPI 77 (Epoxy Cold Cured, Gloss (EC)) MPI 98 (High Build Epoxy Coating) MPI 108 (High Build Epoxy Marine Coating (EC)) finish.
3.8 EXTERIOR FINISHES
R. Apply following finish coats where specified in section 09 06 00, schedule for finishes.
S. Wood:
1. Do not apply finish coats on surfaces concealed after installation, top and bottom edges of wood doors and sash, or on edges of wood framed insect screens.
2. Two (2) coats of // MPI 10 Exterior Latex, Flat) // // MPI 11 (Exterior Latex, Semi-Gloss) // // MPI 119 (Exterior Latex, High Gloss (acrylic)) // on exposed surfaces, except where transparent finish is specified.
3. Two (2) coats of // MPI 31 (Polyurethane, Moisture Cured, Clear Gloss) // // MPI 71 (Polyurethane, Moisture Cured, Clear Flat) // for transparent finish.
T. Steel and Ferrous Metal //, Including Tern //:
1. Two (2) coats of // MPI 8 (Exterior Alkyd, Flat) // // MPI 9 (Exterior Alkyd Enamel) // // MPI 94 (Exterior Alkyd, Semi-Gloss) // on exposed surfaces, except on surfaces over 94 degrees C (201 degrees F).
2. One (1) coat of MPI 22 (High Heat Resistant Coating) on surfaces over 94 degrees K (290 degrees F) and on surfaces of // boiler // //, incinerator // //, stacks // engine exhaust pipes.
U. Machinery without factory finish except for primer: One (1) coat // MPI 8 (Exterior Alkyd, Flat) // // MPI 9 (Exterior Alkyd Enamel) // // MPI 94 (Exterior Alkyd, Semi-Gloss) //.
V. Concrete Masonry Units // Brick // // Cement Plaster // // Concrete //:
1. General:
a. Where specified in Section 09 06 00, SCHEDULE FOR FINISHES or shown.
b. Mix as specified in manufacturer's printed directions.
c. Do not mix more paint than can be used within four (4) hours after mixing. Discard paint that has started to set.
d. Dampen warm surfaces above 24 degrees C (75 degrees F) with fine mist of water before application of paint. Do not leave free water on surface.
e. Cure paint with a fine mist of water as specified in manufacturer's printed instructions.
2. Use two (2) coats of TT-P-1411 (Paint, Co-polymer-Resin, Cementitious), unless specified otherwise.
3.9 INTERIOR FINISHES
A.
Apply following finish coats over prime coats in spaces or on surfaces specified in Section 09 06 00, SCHEDULE FOR FINISHES.
B.
Gypsum Board:
1.
One coat of MPI 45 (Interior Primer Sealer) MPI 46 (Interior Enamel Undercoat) plus one coat of MPI 139 (Interior High Performance Latex, MPI Gloss level 3 (LL)).
2.
Two coats of MPI 138 (Interior High Performance Latex, MPI Gloss Level 2 (LF)).
3.
One coat of MPI 45 (Interior Primer Sealer) MPI 46 (Interior Enamel Undercoat) plus one coat of MPI 54 (Interior Latex, Semi-Gloss, MPI Gloss Level 5 (LE)) or MPI 114 (Interior Latex, Gloss (LE) and (LG)).
4.
One coat of MPI 45 (Interior Primer Sealer) MPI 46 (Interior Enamel Undercoat) plus one coat of MPI 48 (Interior Alkyd Gloss (AK)).
C.
Sealers:
a.
Apply sealers specified except sealer may be omitted where pigmented, penetrating, or wiping stains containing resins are used.
b.
Allow manufacturer's recommended drying time before sanding, but not less than 24 hours or 36 hours in damp or muggy weather.
c.
Sand as specified.
D.
Paint Finish:
a.
One coat of MPI 45 (Interior Primer Sealer) MPI 46 (Interior Enamel Undercoat) plus one coat of MPI 47 (Interior Alkyd, Semi-Gloss (AK)) (SG).
b.
One coat MPI 66 (Interior Alkyd Fire retardant, Clear Top-Coat (ULC Approved) (FC) MPI 67 (Interior Latex Fire Retardant, Top-Coat (ULC Approved) (FR), intumescent type (FR), on exposed wood in attics with floors used for mechanical equipment and above ceilings where shown.
c.
One coat of MPI 45 Interior Primer Sealer) MPI 46 (Interior Enamel Undercoat) plus one coat of MPI 48 (Interior Alkyd Gloss (AK)).
d.
Two coats of MPI 51 (Interior Alkyd, Eggshell) (AK)).
3.10 REFINISHING EXISTING PAINTED SURFACES
A.
Clean, patch and repair existing surfaces as specified under “Surface Preparation”. No “telegraphing” of lines, ridges, flakes, etc., through new surfacing is permitted. Where this occurs, sand smooth and re-finish until surface meets with COR’s approval.
B.
Remove and reinstall items as specified under surface preparation.
C.
Remove existing finishes or apply separation coats to prevent non compatible coatings from having contact.
D.
Patched or Replaced Areas in Surfaces and Components: Apply spot prime and body coats as specified for new work to repaired areas or replaced components.
E.
Except where scheduled for complete painting apply finish coat over plane surface to nearest break in plane, such as corner, reveal, or frame.
F.
In existing rooms and areas where alterations occur, clean existing stained and natural finished wood retouch abraded surfaces and then give entire surface one coat of MPI 31 (Polyurethane, Moisture Cured, Clear Gloss) MPI 71 (Polyurethane, Moisture Cured, Clear Flat (PV)).
G.
Refinish areas as specified for new work to match adjoining work unless specified or scheduled otherwise.
H.
Coat knots and pitch streaks showing through old finish with MPI 36 (Knot Sealer) before refinishing.
I.
Sand or dull glossy surfaces prior to painting.
J.
Sand existing coatings to a feather edge so that transition between new and existing finish will not show in finished work.
3.11 PAINT COLOR
A.
Color and gloss of finish coats is specified by COR.
B.
For additional requirements regarding color see Articles, REFINISHING EXISTING PAINTED SURFACE and MECHANICAL AND ELECTRICAL FIELD PAINTING SCHEDULE.
C.
Coat Colors:
1.
Color of priming coat: Lighter than body coat.
2.
Color of body coat: Lighter than finish coat.
3.
Color prime and body coats to not show through the finish coat and to mask surface imperfections or contrasts.
D.
Painting, Caulking, Closures, and Fillers Adjacent to Casework:
1.
Paint to match color of casework where casework has a paint finish.
2.
Paint to match color of wall where casework is stainless steel, plastic laminate, or varnished wood.
3.12 MECHANICAL AND ELECTRICAL WORK FIELD PAINTING SCHEDULE
Not Applicable.
3.13 BUILDING AND STRUCTURAL WORK FIELD PAINTING
W. Painting and finishing of interior and exterior work except as specified here-in-after.
1. Painting and finishing of new // and existing // work including colors and gloss of finish selected is specified in Finish Schedule, Section 09 06 00, SCHEDULE FOR FINISHES.
2. Painting of disturbed, damaged and repaired or patched surfaces when entire space is not scheduled for complete repainting or refinishing.
3. Painting of ferrous metal and galvanized metal.
4. Painting of wood with fire retardant paint exposed in attics, when used as mechanical equipment space (except shingles).
5. Identity painting and safety painting.
X. Building and Structural Work not Painted:
1. Prefinished items:
a. Casework, doors, elevator entrances and cabs, metal panels, wall covering, and similar items specified factory finished under other sections.
b. Factory finished equipment and pre-engineered metal building components such as metal roof and wall panels.
2. Finished surfaces:
a. Hardware except ferrous metal.
b. Anodized aluminum, stainless steel, chromium plating, copper, and brass, except as otherwise specified.
c. Signs, fixtures, and other similar items integrally finished.
3. Concealed surfaces:
a. Inside dumbwaiter, elevator and duct shafts, interstitial spaces, pipe basements, crawl spaces, pipe tunnels, above ceilings, attics, except as otherwise specified.
b. Inside walls or other spaces behind access doors or panels.
c. Surfaces concealed behind permanently installed casework and equipment.
4. Moving and operating parts:
a. Shafts, chains, gears, mechanical and electrical operators, linkages, and sprinkler heads, and sensing devices.
b. Tracks for overhead or coiling doors, shutters, and grilles.
5. Labels:
a. Code required label, such as Underwriters Laboratories Inc., Intertek Testing Service or Factory Mutual Research Corporation.
b. Identification plates, instruction plates, performance rating, and nomenclature.
6. Galvanized metal:
a. Exterior chain link fence and gates, corrugated metal areaways, and gratings.
b. Gas Storage Racks.
c. Except where specifically specified to be painted.
7. Metal safety treads and nosings.
8. Gaskets.
9. Concrete curbs, gutters, pavements, retaining walls, exterior exposed foundations walls and interior walls in pipe basements.
10. Face brick.
11. Structural steel encased in concrete, masonry, or other enclosure.
12. Structural steel to receive sprayed-on fire proofing.
13. Ceilings, walls, columns in interstitial spaces.
14. Ceilings, walls, and columns in pipe basements.
15. Wood Shingles.
3.14 IDENTITY PAINTING SCHEDULE
Not Applicable.
3.15 PROTECTION CLEAN UP, AND TOUCH-UP
A.
Protect work from paint droppings and spattering by use of masking, drop cloths, removal of items or by other approved methods.
B.
Upon completion, clean paint from hardware, glass and other surfaces and items not required to be painted of paint drops or smears.
C.
Before final inspection, touch-up or refinished in a manner to produce solid even color and finish texture, free from defects in work which was damaged or discolored.
- - - E N D - - -