5-SLCI27036 Attachment 5 Flare Design.pdf
PDF 10 MB Posted
- Solicitation number
- SLCI27036
- Issued by
- Salt Lake County, Salt Lake City, Utah
About this file
This is a flare design attachment document for a Salt Lake City Corporation request for bid (SLCI27036) regarding a landfill gas blower/flare system equipment procurement in Utah. The document provides technical specifications and design parameters for the flare component of the proposed landfill gas management system. The flare system is a critical element of the overall blower/flare system that Salt Lake City is seeking from qualified manufacturers through competitive sealed bidding. This attachment establishes the technical requirements and performance standards that bidders must meet when designing and manufacturing the flare equipment as part of their comprehensive system proposals.
The flare design specifications detailed in this attachment serve as binding technical criteria that all qualified bidders must incorporate into their equipment offerings. Bidders are required to demonstrate compliance with these design standards to be considered responsive to Salt Lake City's request for bid. The specifications establish operational parameters, safety requirements, emissions controls, and material specifications necessary for the flare system to function effectively within the overall landfill gas management infrastructure at Salt Lake City's facility.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALT LAKE CITY
CORPORATION
ENGINEERING DIVISION
SALT LAKE CITY
CORPORATION
COMMUNITY AND
NEIGHBORHOODS
I C
T Y
S A L
T L A K E
SLVSWMF
FLARE DESIGN
BASIS 40%
GENERAL
INFORMATION
SITE
ORIENTATION
MAP
GI 001
DRAFT
BLUE STAKES OF UTAH
Utility Notification Center, Inc.
1-800-662-4111 www.bluestakes.org
Dig Safely. Know what'sbelow.
Callbefore you dig.
CALL BEFORE YOU DIG.
SURVEY-BENCHMARK
SURVEY-STREET MONUMENT
BID ITEM
KEY NOTE
EXISTING STORM DRAIN
sd sd sd
AVERY HOLYOAK S.L.C. PROJECT ENGINEER
EMAIL: AVERY.HOLYOAK@SLC.GOV
PHONE: (801) 913-4946
LEON FORD S.L.V.S.W.M.F. OPERATIONS MANAGER
EMAIL: LFORD@SALTLAKECOUNTY.GOV
PHONE: (801) 381-8670
RELOCATION OF ANY UTILITY BOXES, MANHOLES, OR OTHER SURFACE UTILITIES, OTHER THAN RAISING THEM TO THE NEW GRADE, REQUIRES APPROVAL, OF THE NEW LOCATION, BY THE PROJECT INSPECTOR PRIOR TO REMOVING IT FROM ITS ORIGINAL LOCATION. COORDINATE WITH THE PROJECT INSPECTOR A MINIMUM OF 48
HOURS PRIOR TO DISTURBING FACILITIES IN ANY WAY.
GRAVEL
CONCRETE
EXISTING GAS CONTROL VALVE
PROPOSED GAS CONTROL VALVE
EXISTING GAS PIPELINE
G
PROPOSED POWER
P
PROPOSED CHAIN-LINK FENCE
EXISTING UNDERGROUND POWER
P-UG
EXISTING OVERHEAD POWER
P-OH
PROPOSED COMPRESSED AIRLINE
AIR
PROPOSED GAS PIPELINE
G
PROPOSED FLARE DRAIN LINE
FD
PROPOSED 24" STORM DRAIN
24-SD
PROPOSED CONTOUR LINES
EXISTING CONTOUR LINES
SALT LAKE CITY
CORPORATION
ENGINEERING DIVISION
SALT LAKE CITY
CORPORATION
COMMUNITY AND
NEIGHBORHOODS
I C
T Y
S A
L
T L A K
E
SLVSWMF
FLARE DESIGN
BASIS 40%
GENERAL
INFORMATION
LEGEND AND
GENERAL NOTES
GI 002
ENGINEERING DIVISION
SALT LAKE CITY
CORPORATION
COMMUNITY AND
NEIGHBORHOODS
I C
T Y
S A L
T L A K E
SLVSWMF
FLARE DESIGN
BASIS 40%
SITE
PLAN
EXISTING
CONDITIONS
SP 101
ENGINEERING DIVISION
SALT LAKE CITY
CORPORATION
COMMUNITY AND
NEIGHBORHOODS
I C
T Y
S A L
T L A K E
SLVSWMF
FLARE DESIGN
BASIS 40%
PROPOSED
PLAN
SP 102
ENGINEERING DIVISION
SALT LAKE CITY
CORPORATION
COMMUNITY AND
NEIGHBORHOODS
I C
T Y
S A L
T L A K E
SLVSWMF
FLARE DESIGN
BASIS 40%
GRADING
PROPOSED
GRADING
PLAN
GR 101
FD
P P
P
SALT LAKE CITY
CORPORATION
ENGINEERING DIVISION
SALT LAKE CITY
CORPORATION
COMMUNITY AND
NEIGHBORHOODS
I C
T Y
S A L
T L A K E
SLVSWMF
FLARE DESIGN
BASIS 40%
DETAILS
FLARE /
BLOWER STATION
DETAILS
DT 101
P
G
AIR
| SLVSWMF Design Basis 40% SLC Plan Set.pdf |
| Sheets and Views |
| Design Basis 40% SLC Plan Set - SE-COVER |
| Design Basis 40% SLC Plan Set - SE-GI 001 |
| Design Basis 40% SLC Plan Set - SE-GI 002 |
| Design Basis 40% SLC Plan Set - SE-SP 101 |
| Design Basis 40% SLC Plan Set - SE-SP 102 |
| Design Basis 40% SLC Plan Set - SE-GR 101 |
| Design Basis 40% SLC Plan Set - SE-DT 101 |
File details come from the government source that posted it. Updated .