About this file
This is a ceiling repair specification document prepared by Schoonover & Architects, LLC for the Housing Authority of Monroe County (HAMC) covering three residential properties: Barnum Street, Kistler Street, and Lenox Avenue. The project involves refastening and finishing gypsum board ceilings across 44 total residential units—17 units at Barnum Street, 15 units at Kistler Street, and 12 units at Lenox Avenue. The scope of work includes assessment of existing gypsum board conditions, removal and replacement of popped fasteners, installation of Type S bugle-head drywall screws at 8-inch on-center spacing per GA-216 and ASTM C840 standards, re-taping of joints with paper or fiberglass mesh tape, application of two additional coats of joint compound, and provision of Level 4 gypsum and paint finishes. At Barnum Street, all second floor ceilings and stairs in two-story units and all first floor ceilings in one-story units are included; Unit 126C is excluded from the contract. At Kistler Street, all 15 units are two-story structures with second floor ceiling repairs specified. At Lenox Avenue, all 12 units are two-story structures with second floor ceiling repairs required; Unit 171 (garage) is excluded from the contract. The contractor must coordinate scheduling with HAMC to inform tenants, provide appropriate staging areas at each location, and protect all surfaces below ceilings from damage during repair operations.
The specification requires paint to be Sherwin Williams Snowbound White with eggshell finish and manufacturer-specified primer applied to entire ceiling surfaces. For sagging ceilings exceeding 1/8 inch from framing, replacement of gypsum board panels with Type X or sag-resistant board is recommended instead of refastening. All fixtures such as lights and fans must be removed and replaced as necessary to accommodate ceiling repairs. Fire-rated assemblies must maintain fastener spacing, board orientation, and joint treatment per UL design specifications. The contractor is responsible for all costs associated with replacing any properties or surfaces damaged during ceiling repair work. Unit pricing is requested for materials and labor costs of reinstalling gypsum board at all required locations as specified in the refastening ceiling gypsum board notes. The document is marked as a review set dated November 3, 2025 and noted as "NOT FOR CONSTRUCTION," indicating this is preliminary design documentation prepared in conjunction with Invitation for Bids (IFB) 2025-04.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B A R N U M S T R E E T
1 STORY 1 STORY
1 STORY
1 STORY
2 STORY
2 STORY
2 STORY
2 STORY
PARKING
1 STORY
1 STORY 1 STORY 1 STORY
1 STORY 1 STORY
2 STORY
2 STORY
2 STORY
2 STORY
A
B
C
D
124 122 A B
C D A B C
A B C
A
B
C
D
UNIT 126C - NOT
IN CONTRACT
Verify existing gypsum board thickness (typically ½" or ⅝").
Locate areas of looseness by tapping or gently pressing.
Identify existing framing layout (joists, furring channels, trusses).
Remove fasteners that have popped or lost grip.
Cut back any loose tape or cracked joint compound.
If significant sagging exists (>½" from framing), replacement of gypsum board panel is recommended instead of refastening.
Screws: Use Type S bugle-head drywall screws (coarse thread for wood framing, fine thread for metal framing).
For ½" board: #6 screws, min. 1¼" length into wood framing
For ⅝" board: #6 screws, min. 1⅝" length into wood framing
Fastener spacing (per GA-216 & ASTM C840):
Ceilings, wood framing: max. 8" o.c.
Edge distance: ⅜" from tapered edges, ½" from cut ends.
REFASTENING CEILING GYPSUM BOARD NOTES:
1. ASSESSMENT
2. PREPARATION
3. FASTENING REQUIREMENTS
4. PROCEDURE
N. K I S T L E R S T R E E T
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
S
T O R
Y
S
T O R
Y
S
T O R
Y
S
T O R
Y
S
T O R
Y
S
T O R
Y
S
T O R
Y
PARKING
L E N O X A V E N U E
A
GARAGE
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
PARKING
B
C
D
E
F
A
B
C
D
E
F
GARAGE 171 - NOT
IN CONTRACT
Drive screws so that heads are slightly dimpled below surface without breaking paper face.
Add supplemental screws between original fasteners, maintaining required spacing.
Where board edges are not supported by framing, install backing
(wood blocking or drywall repair clips) @ REPLACEMENT LOCATIONS
PROVIDE adhesive AND screws @ REPLACEMENT LOCATIONS - USE adhesive approved for gypsum board.
REMOVE AND REPLACE FIXTURES SUCH AS LIGHTS, FANS, ETC. AS REQUIRED TO
ACCOMMODATE CEILING REPAIR
Re-tape joints with paper or fiberglass mesh tape and setting-type joint compound.
Apply two additional coats of joint compound, feathering each coat wider.
Sand smooth and prepare surface for paint or finish.
PROVIDE LEVEL 4 GYPSUM FINISH
PROVIDE LEVEL 4 PAINT FINISH - PAINT SHALL BE SHERWIN WILLIAMS -
SNOWBOUND WHITE WITH EGGSHELL FINISH AND PRIMER SPECIFIED BY THE
MANUFACTURER - ENTIRE CEILING SURFACE IN ALL LOCATIONS CALLED OUT IN
DRAWINGS SHALL RECEIVE A NEW FINISH.
For fire-rated assemblies: maintain fastener spacing, board orientation, and joint treatment per UL design.
For sagging ceilings in humid areas: use ⅝" Type X or sag-resistant gypsum board @ replacement LOCATIONS
4. PROCEDURE
5. FINISHING
6. SPECIAL CONSIDERATIONS
CONTRACTOR SHALL PROVIDE A UNIT PRICE TO PROVIDE MATERIALS AND
LABOR COSTS OF REINSTALLING GYPSUM BOARD AT REQUIRED LOCATIONS AS
SPECIFIED IN REFASTENING "CEILING GYPSUM BOARD NOTES, 2. PREPARATION, If significant sagging exists (>½" from framing), replacement of gypsum board panel is recommended instead of refastening."
UNIT COST REQUEST:
STAGING AREAS AT EACH LOCATION SHALL BE DETERMINED
STAGING:
CONTRACTOR SHALL COORDINATE WITH HOUSING AUTHORITY OF MONROE COUNTY
AS TO SCHEDULING AND INFORMING TENANTS WHEN WORK WILL TAKE PLACE.
SCHEDULING ACCESS TO EACH UNIT:
CONTRACTOR SHALL PROTECT ALL SURFACES BELOW CEILINGS FROM BEING
DAMAGED DURING CEILING REPAIR. CONTRACTOR SHALL BE RESPONSIBLE FOR
ALL COSTS AND REPLACING DAMAGE PROPERTIES IN WHICH WAS CAUSED BY
THE CONTRACTOR DURING CEILING REPAIR.
PROTECTION OF ADJACENT SURFACES AND PROPERTIES:
CEILING REPAIR LOCATIONS INCLUDE ALL SECOND FLOOR SPACES AND STAIRS
AT TWO STORY UNITS AND ALL FIRST FLOOR SPACES AT ONE STORY UNITS
CONTRACTED CEILING LOCATIONS:
(5
4-
S V
N
OR
TH
C
OU
RT
LA
ND
S
TR
EE
T, EA
ST
S
TR
OU
DS
BU
RG
, P
A
SC
H
O O
N O
VE
R
AR
C
H
IT
EC
TS
LL
C
FA
X:
(5
4-
VA
N
D
ER
H O
O F
25-07-05
AS NOTED
11/3/2025REVIEW SET: 11/3/2025 - NOT FOR CONSTRUCTION
HOUSING AUTHORITY of MONROE COUNTY
CEILING REPAIR @
for the
BARNUM - KISTLER - LENOX UNITS
C100
COVER SHEET
IFB : 2025-04
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SEAL:
AutoCAD SHX Text
LIC. # - NJ= #7960
AutoCAD SHX Text
%%UWAYNE W. VANDERHOOF
AutoCAD SHX Text
LIC. # - PA= #RA-009145-B
AutoCAD SHX Text
LIC. # - NJ= #10102
AutoCAD SHX Text
LIC. # - NC= #5587
AutoCAD SHX Text
LIC. # - NY= #020142
AutoCAD SHX Text
LIC. # - PA= #RA-010286-X
AutoCAD SHX Text
LIC. # - MD= #6547
AutoCAD SHX Text %%uJOHN S. SCHOONOVER JR.
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
JOB NO.
AutoCAD SHX Text
SCALE
B A R N U M S T R E E T
1 STORY 1 STORY
1 STORY
1 STORY
2 STORY
2 STORY
2 STORY
2 STORY
PARKING
1 STORY
1 STORY 1 STORY 1 STORY
1 STORY 1 STORY
2 STORY
2 STORY
2 STORY
2 STORY
A
B
C
D
124 122 A B
C D A B C
A B C
A
B
C
D
UNIT 126C - NOT
IN CONTRACT
BEDROOM
LIVING ROOM
BATH
DININGKITCHEN
MECH.
LAUNDRY
STORAGE
A A
A
A
A
A
A
A
A
1. PROVIDE LEVEL 4 GYPSUM FINISH
TYPICAL CEILING REPAIR NOTES:
2. PROVIDE LEVEL 4 PAINT FINISH
3. INSTALL 1 1
4"- 1
8" TYPE 'S' SCREWS
BUGLE HEAD @ 8" O.C. THROUGHOUT
A
CEILING REPAIR LOCATIONS INCLUDE ALL
SECOND FLOOR SPACES AND STAIRS AT
TWO STORY UNITS AND ALL FIRST FLOOR
SPACES AT ONE STORY UNITS
CONTRACTED CEILING LOCATIONS:
BEDROOM
BATHRM.
BEDROOM
HALL
STAIR STAIR
BEDROOM
BEDROOM
HALL
BATHRM.
AA
A A
AA
A A
A A
AA
AA
TENANTTENANT
UNIT NUMBER CEILING LOCATION
120A SECOND FLOOR CEILING
120B SECOND FLOOR CEILING
120C SECOND FLOOR CEILING
120D SECOND FLOOR CEILING
122A FIRST FLOOR CEILING
SECOND FLOOR CEILING
SECOND FLOOR CEILING
NOT IN CONTRACT
SECOND FLOOR CEILING
FIRST FLOOR CEILING
FIRST FLOOR CEILING
122B
122C
124A
124B
124C
124D
126A
FIRST FLOOR CEILING
FIRST FLOOR CEILING
FIRST FLOOR CEILING
FIRST FLOOR CEILING
126B
126C
126D
FIRST FLOOR CEILING
FIRST FLOOR CEILING
FIRST FLOOR CEILING
128A
128B
128C
BARNUM STREET UNITS
(17) SEVENTEEN UNITS IN CONTRACT @ BARNUM
Verify existing gypsum board thickness (typically ½" or ⅝").
Locate areas of looseness by tapping or gently pressing.
Identify existing framing layout (joists, furring channels, trusses).
Remove fasteners that have popped or lost grip.
Cut back any loose tape or cracked joint compound.
If significant sagging exists (>½" from framing), replacement of gypsum board panel is recommended instead of refastening.
Screws: Use Type S bugle-head drywall screws (coarse thread for wood framing, fine thread for metal framing).
For ½" board: #6 screws, min. 1¼" length into wood framing
For ⅝" board: #6 screws, min. 1⅝" length into wood framing
Fastener spacing (per GA-216 & ASTM C840):
Ceilings, wood framing: max. 8" o.c.
Edge distance: ⅜" from tapered edges, ½" from cut ends.
Drive screws so that heads are slightly dimpled below surface without breaking paper face.
Add supplemental screws between original fasteners, maintaining required spacing.
Where board edges are not supported by framing, install backing
(wood blocking or drywall repair clips) @ REPLACEMENT LOCATIONS
PROVIDE adhesive AND screws @ REPLACEMENT LOCATIONS - USE adhesive approved for gypsum board.
REMOVE AND REPLACE FIXTURES SUCH AS LIGHTS, FANS, ETC. AS REQUIRED TO
ACCOMMODATE CEILING REPAIR
Re-tape joints with paper or fiberglass mesh tape and setting-type joint compound.
Apply two additional coats of joint compound, feathering each coat wider.
Sand smooth and prepare surface for paint or finish.
PROVIDE LEVEL 4 GYPSUM FINISH
PROVIDE LEVEL 4 PAINT FINISH - PAINT SHALL BE SHERWIN WILLIAMS -
SNOWBOUND WHITE WITH EGGSHELL FINISH AND PRIMER SPECIFIED BY THE
MANUFACTURER - ENTIRE CEILING SURFACE IN ALL LOCATIONS CALLED OUT IN
DRAWINGS SHALL RECEIVE A NEW FINISH.
For fire-rated assemblies: maintain fastener spacing, board orientation, and joint treatment per UL design.
For sagging ceilings in humid areas: use ⅝" Type X or sag-resistant gypsum board @ replacement LOCATIONS
REFASTENING CEILING GYPSUM BOARD NOTES:
1. ASSESSMENT
2. PREPARATION
3. FASTENING REQUIREMENTS
4. PROCEDURE
5. FINISHING
6. SPECIAL CONSIDERATIONS
ITEM
REVISIONS
NO. DATE
SEAL:
LIC. # - NJ= #7960
WAYNE W. VANDERHOOF
LIC. # - PA= #RA-009145-B
LIC. # - NJ= #10102
LIC. # - NC= #5587
LIC. # - NY= #020142
LIC. # - PA= #RA-010286-X
LIC. # - MD= #6547
JOHN S. SCHOONOVER JR.
(5
4-
S
DRAWN
DATE
SHEET
JOB NO.
SCALE
V
N
OR
TH
C
OU
RT
LA
ND
S
TR
EE
T, EA
ST
S
TR
OU
DS
BU
RG
, P A
SC
H
O O
N O
VE
H
IT
EC
TS
LL
C
FA
X:
(5
4-
VA
N
D
ER
H O
O F
25-07-05
AS NOTED
11/3/2025REVIEW SET: 11/3/2025 - NOT FOR CONSTRUCTION
H O
U
SI
N G
A U
TH
O
R
IT
Y of
M O
N R
O E
C O
U N
TY
CE
ILI
NG
R
EP
AI
R fo r t he
BA
R N
U M
KI
ST
LE
R
LE
N
O X
U N
IT
S
SCALE: 1/4"= 1'-0"
TYPICAL FIRST FLOOR REFLECTED CEILING PLAN
SCALE: 1/4"= 1'-0"
TYPICAL SECOND FLOOR REFLECTED CEILING PLAN
@ ONE STORY UNITS / SOME UNITS MAY HAVE PLAN VARIATIONS OR MIRRORED LAYOUTS @ TWO STORY UNITS / SOME UNITS MAY HAVE PLAN VARIATIONS OR MIRRORED LAYOUTS
A100
BARNUM
STREET UNITS
SCALE: NOT TO SCALE
LOCATION MAP
N. K I S T L E R S T R E E T
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
S
T O R
Y
S
T O R
Y
S
T O R
Y
S
T O R
Y
S
T O R
Y
S
T O R
Y
S
T O R
Y
PARKING
BEDROOM
BATHRM.
BEDROOM
HALL
STAIR STAIR
BEDROOM
BEDROOM
HALL
BATHRM.
AA
A A
AA
A A
A A
AA
AA
TENANTTENANT
UNIT NUMBER CEILING LOCATION
312 SECOND FLOOR CEILING
KISTLER STREET UNITS
SECOND FLOOR CEILING
SECOND FLOOR CEILING
SECOND FLOOR CEILING
320 SECOND FLOOR CEILING
322 SECOND FLOOR CEILING
324 SECOND FLOOR CEILING
326 SECOND FLOOR CEILING
328 SECOND FLOOR CEILING
330 SECOND FLOOR CEILING
332 SECOND FLOOR CEILING
334 SECOND FLOOR CEILING
336 SECOND FLOOR CEILING
338 SECOND FLOOR CEILING
340 SECOND FLOOR CEILING
(15) FIFTEEN UNITS IN CONTRACT @ KISTLER
1. PROVIDE LEVEL 4 GYPSUM FINISH
TYPICAL CEILING REPAIR NOTES:
2. PROVIDE LEVEL 4 PAINT FINISH
3. INSTALL 1 1
4"- 1
8" TYPE 'S' SCREWS
BUGLE HEAD @ 8" O.C. THROUGHOUT
A
CEILING REPAIR LOCATIONS INCLUDE ALL
SECOND FLOOR SPACES AND STAIRS AT
TWO STORY UNITS AND ALL FIRST FLOOR
SPACES AT ONE STORY UNITS
CONTRACTED CEILING LOCATIONS:
Verify existing gypsum board thickness (typically ½" or ⅝").
Locate areas of looseness by tapping or gently pressing.
Identify existing framing layout (joists, furring channels, trusses).
Remove fasteners that have popped or lost grip.
Cut back any loose tape or cracked joint compound.
If significant sagging exists (>½" from framing), replacement of gypsum board panel is recommended instead of refastening.
Screws: Use Type S bugle-head drywall screws (coarse thread for wood framing, fine thread for metal framing).
For ½" board: #6 screws, min. 1¼" length into wood framing
For ⅝" board: #6 screws, min. 1⅝" length into wood framing
Fastener spacing (per GA-216 & ASTM C840):
Ceilings, wood framing: max. 8" o.c.
Edge distance: ⅜" from tapered edges, ½" from cut ends.
Drive screws so that heads are slightly dimpled below surface without breaking paper face.
Add supplemental screws between original fasteners, maintaining required spacing.
Where board edges are not supported by framing, install backing
(wood blocking or drywall repair clips) @ REPLACEMENT LOCATIONS
PROVIDE adhesive AND screws @ REPLACEMENT LOCATIONS - USE adhesive approved for gypsum board.
REMOVE AND REPLACE FIXTURES SUCH AS LIGHTS, FANS, ETC. AS REQUIRED TO
ACCOMMODATE CEILING REPAIR
Re-tape joints with paper or fiberglass mesh tape and setting-type joint compound.
Apply two additional coats of joint compound, feathering each coat wider.
Sand smooth and prepare surface for paint or finish.
PROVIDE LEVEL 4 GYPSUM FINISH
PROVIDE LEVEL 4 PAINT FINISH - PAINT SHALL BE SHERWIN WILLIAMS -
SNOWBOUND WHITE WITH EGGSHELL FINISH AND PRIMER SPECIFIED BY THE
MANUFACTURER - ENTIRE CEILING SURFACE IN ALL LOCATIONS CALLED OUT IN
DRAWINGS SHALL RECEIVE A NEW FINISH.
For fire-rated assemblies: maintain fastener spacing, board orientation, and joint treatment per UL design.
For sagging ceilings in humid areas: use ⅝" Type X or sag-resistant gypsum board @ replacement LOCATIONS
REFASTENING CEILING GYPSUM BOARD NOTES:
1. ASSESSMENT
2. PREPARATION
3. FASTENING REQUIREMENTS
4. PROCEDURE
5. FINISHING
6. SPECIAL CONSIDERATIONS
ITEM
REVISIONS
NO. DATE
SEAL:
LIC. # - NJ= #7960
WAYNE W. VANDERHOOF
LIC. # - PA= #RA-009145-B
LIC. # - NJ= #10102
LIC. # - NC= #5587
LIC. # - NY= #020142
LIC. # - PA= #RA-010286-X
LIC. # - MD= #6547
JOHN S. SCHOONOVER JR.
(5
4-
S
DRAWN
DATE
SHEET
JOB NO.
SCALE
V
N
OR
TH
C
OU
RT
LA
ND
S
TR
EE
T, EA
ST
S
TR
OU
DS
BU
RG
, P A
SC
H
O O
N O
VE
H
IT
EC
TS
LL
C
FA
X:
(5
4-
VA
N
D
ER
H O
O F
25-07-05
AS NOTED
11/3/2025REVIEW SET: 11/3/2025 - NOT FOR CONSTRUCTION
H O
U
SI
N G
A U
TH
O
R
IT
Y of
M O
N R
O E
C O
U N
TY
CE
ILI
NG
R
EP
AI
R fo r t he
BA
R N
U M
KI
ST
LE
R
LE
N
O X
U N
IT
S
SCALE: 1/4"= 1'-0"
TYPICAL SECOND FLOOR REFLECTED CEILING PLAN
@ TWO STORY UNITS / SOME UNITS MAY HAVE PLAN VARIATIONS OR MIRRORED LAYOUTS
A101
KISTLER
STREET UNITS
L E N O X A V E N U E
A
GARAGE
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
2 STORY
PARKING
B
C
D
E
F
A
B
C
D
E
F
GARAGE 171 - NOT
IN CONTRACT
BEDROOM
BATHRM.
BEDROOM
HALL
STAIR STAIR
BEDROOM
BEDROOM
HALL
BATHRM.
AA
A A
AA
A A
A A
AA
AA
TENANTTENANT
UNIT NUMBER CEILING LOCATION
163A SECOND FLOOR CEILING
LENOX AVE. UNITS
SECOND FLOOR CEILING
SECOND FLOOR CEILING
SECOND FLOOR CEILING
SECOND FLOOR CEILING
SECOND FLOOR CEILING
SECOND FLOOR CEILING
SECOND FLOOR CEILING
SECOND FLOOR CEILING
SECOND FLOOR CEILING
SECOND FLOOR CEILING
SECOND FLOOR CEILING
163B
163C
163D
163E
163F
179A
179B
179C
179D
179E
179F
(12) TWELVE UNITS IN CONTRACT @ LENOX
NOT IN CONTRACT171 (GARAGE)
1. PROVIDE LEVEL 4 GYPSUM FINISH
TYPICAL CEILING REPAIR NOTES:
2. PROVIDE LEVEL 4 PAINT FINISH
3. INSTALL 1 1
4"- 1
8" TYPE 'S' SCREWS
BUGLE HEAD @ 8" O.C. THROUGHOUT
A
CEILING REPAIR LOCATIONS INCLUDE ALL
SECOND FLOOR SPACES AND STAIRS AT
TWO STORY UNITS AND ALL FIRST FLOOR
SPACES AT ONE STORY UNITS
CONTRACTED CEILING LOCATIONS:
Verify existing gypsum board thickness (typically ½" or ⅝").
Locate areas of looseness by tapping or gently pressing.
Identify existing framing layout (joists, furring channels, trusses).
Remove fasteners that have popped or lost grip.
Cut back any loose tape or cracked joint compound.
If significant sagging exists (>½" from framing), replacement of gypsum board panel is recommended instead of refastening.
Screws: Use Type S bugle-head drywall screws (coarse thread for wood framing, fine thread for metal framing).
For ½" board: #6 screws, min. 1¼" length into wood framing
For ⅝" board: #6 screws, min. 1⅝" length into wood framing
Fastener spacing (per GA-216 & ASTM C840):
Ceilings, wood framing: max. 8" o.c.
Edge distance: ⅜" from tapered edges, ½" from cut ends.
Drive screws so that heads are slightly dimpled below surface without breaking paper face.
Add supplemental screws between original fasteners, maintaining required spacing.
Where board edges are not supported by framing, install backing
(wood blocking or drywall repair clips) @ REPLACEMENT LOCATIONS
PROVIDE adhesive AND screws @ REPLACEMENT LOCATIONS - USE adhesive approved for gypsum board.
REMOVE AND REPLACE FIXTURES SUCH AS LIGHTS, FANS, ETC. AS REQUIRED TO
ACCOMMODATE CEILING REPAIR
Re-tape joints with paper or fiberglass mesh tape and setting-type joint compound.
Apply two additional coats of joint compound, feathering each coat wider.
Sand smooth and prepare surface for paint or finish.
PROVIDE LEVEL 4 GYPSUM FINISH
PROVIDE LEVEL 4 PAINT FINISH - PAINT SHALL BE SHERWIN WILLIAMS -
SNOWBOUND WHITE WITH EGGSHELL FINISH AND PRIMER SPECIFIED BY THE
MANUFACTURER - ENTIRE CEILING SURFACE IN ALL LOCATIONS CALLED OUT IN
DRAWINGS SHALL RECEIVE A NEW FINISH.
For fire-rated assemblies: maintain fastener spacing, board orientation, and joint treatment per UL design.
For sagging ceilings in humid areas: use ⅝" Type X or sag-resistant gypsum board @ replacement LOCATIONS
REFASTENING CEILING GYPSUM BOARD NOTES:
1. ASSESSMENT
2. PREPARATION
3. FASTENING REQUIREMENTS
4. PROCEDURE
5. FINISHING
6. SPECIAL CONSIDERATIONS
ITEM
REVISIONS
NO. DATE
SEAL:
LIC. # - NJ= #7960
WAYNE W. VANDERHOOF
LIC. # - PA= #RA-009145-B
LIC. # - NJ= #10102
LIC. # - NC= #5587
LIC. # - NY= #020142
LIC. # - PA= #RA-010286-X
LIC. # - MD= #6547
JOHN S. SCHOONOVER JR.
(5
4-
S
DRAWN
DATE
SHEET
JOB NO.
SCALE
V
N
OR
TH
C
OU
RT
LA
ND
S
TR
EE
T, EA
ST
S
TR
OU
DS
BU
RG
, P A
SC
H
O O
N O
VE
H
IT
EC
TS
LL
C
FA
X:
(5
4-
VA
N
D
ER
H O
O F
25-07-05
AS NOTED
11/3/2025REVIEW SET: 11/3/2025 - NOT FOR CONSTRUCTION
H O
U
SI
N G
A U
TH
O
R
IT
Y of
M O
N R
O E
C O
U N
TY
CE
ILI
NG
R
EP
AI
R fo r t he
BA
R N
U M
KI
ST
LE
R
LE
N
O X
U N
IT
S
SCALE: 1/4"= 1'-0"
TYPICAL SECOND FLOOR REFLECTED CEILING PLAN
@ TWO STORY UNITS / SOME UNITS MAY HAVE PLAN VARIATIONS OR MIRRORED LAYOUTS
A102
LENOX
AVENUE UNITS
| Sheets and Views |
| Barnum - Kistler - Lenox - Ceiling Security-C100 Cover Sheet |
| Barnum - Kistler - Lenox - Ceiling Security-A100 Barnum Street |
| Barnum - Kistler - Lenox - Ceiling Security-A101 Kistler Street |
| Barnum - Kistler - Lenox - Ceiling Security-A102 Lenox Ave |
File details come from the government source that posted it. Updated .