47PF5327Q0001 Questions and Answers.pdf

PDF 96 KB Posted

Attached to
Elevator Maintenance & Related Services (Columbus, OH & Dayton, OH)
Solicitation number
47PF5327Q0001
Issued by
Not on record

About this file

This is a Questions and Answers document for federal contract 47PF5327Q0001 for Elevator Maintenance & Related Services at four locations: Bricker Federal Building, Bricker Garage, Kinneary USCH, and Rice Federal Building & USCH.

The Q&A clarifies key requirements for the solicitation. The Rice Federal Building contains five elevators total—four passenger elevators and one freight elevator—and an amendment will be issued to remove the sixth elevator listed in the bid documents. Contractors must complete preventative maintenance monthly while on-premise in accordance with Section C.10, with services complying with ASME A17.1 and A18.1 standards, including fire service recall and operation testing. Regarding overtime service calls at nights and weekends, contractors should review Sections C.11, C.12, and C.13 to determine which services are billable; not all overtime calls are automatically reimbursable. On Attachment B, bidders must provide monthly base pricing for all elevators in cells E7-EJ and hourly rates in cells E13, E14, E15 through J13, J14, J15. The contractor is responsible for coordinating and paying for third-party inspection company services for bi-annual and annual/five-year testing; the government has historically used Stuards and Associates. Appendix A requests the number of mechanics assigned to provide services for each specific building based on the performance-based scope of work, not the total mechanics employed by a branch.

View the file

Other files

File Type Posted
Amendment 47PF5327Q0001_0001.pdf PDF
Appendix A - CCW Rice.xlsx XLSX spreadsheet
Attachment A - PWS.pdf PDF
Appendix C - Attendance Form.pdf PDF
Attachment C - 2022-2027-NEBA-Agreement.pdf PDF
Appendix B - Past Performance Form.pdf PDF
Attachment B - Electronic Offer Sheet.xlsx XLSX spreadsheet
Appendix A - CCW Bricker Garage.xlsx XLSX spreadsheet
Attachment C - IUEC -2026 Wage Rates Local 11 for Dayton.pdf PDF
SF 1449 47PF5327Q0001.pdf PDF
Appendix A - CCW Bricker FB.xlsx XLSX spreadsheet
Appendix A - CCW Kinneary.xlsx XLSX spreadsheet
RFQ 47PF5327Q0001.pdf PDF
Attachment C - IUEC -2026 Wage Rates Local 37 Columbus.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

# Question Answer

Does the Rice Building have 5 or 6 elevators? Is there two #1 Cars? When we surveyed the building last week, we were only shown 5 elevators ( Bank of 4 and then a Service Car). This listing below has 6 units shown on the Bid.

The Rice facility has five elevators in total: four passenger elevators and one freight elevator. An amendment will be issued to remove the last row shown in the provided screenshot.

2 Is the expectation that we complete preventative maintenance monthly, along with the monthly fire service testing?

Yes, the expectation is that you complete preventative maintenance monthly and be on-premise in accordance with Section C.10.

Maintenance services must comply with ASME A17.1 and A18.1, which include fire service recall and operation, as well as rules for testing and maintenance.

3 I am reading the Scope of Work as being that service calls we respond to at nights and weekends (Overtime), will be billable at the overtime hourly rate that we submit. Will all overtime calls be billable?

Please ensure you read Sections C.11, C.12, and C.13, as they specify whether the contractor will be reimbursed for services. Please note that references to Section B in these sections refer to Attachment B.

4 On Attachment B you want the monthly base price for all elevators in Cell E7-EJ and the hourly rates for E13,14,15 thru J13,14,15? Yes, that is correct.

47PF5327Q0001 Elevator Maintenance & Related Services Bricker Federal Building, Bricker Garage, Kinneary USCH, Rice Federal Building & USCH

Q&A

# Question Answer

47PF5327Q0001 Elevator Maintenance & Related Services Bricker Federal Building, Bricker Garage, Kinneary USCH, Rice Federal Building & USCH

Q&A

5 Is the Elevator Contractor responsible for the cost and coordination to have the 3rd party inspection company come out for the bi-annual and annual/5year testing? What company do you typically use for this in the past? Yes, Stuards and Associates.

6 The Appendix A file attached ask for # of Employees. Is that asking for the number of mechanic employees assigned to this building or that our Branch has?

Appendix A asks for the number of mechanics that will provide services for that specific building based on the performance based scope of work.