4-SLVSWMF - New Flare - LDF24052 - Plans.pdf
PDF 10 MB Posted
- Attached to
- LDF24052 - SLVSWMF - NEW FLARE
- Solicitation number
- LDF24052
- Issued by
- Salt Lake County, Salt Lake City, Utah
About this file
This is a Plans document for the Salt Lake Valley Solid Waste Management Facility (SLVSWMF) related to a new landfill gas blower/flare system installation project in Salt Lake City, Utah. The project scope encompasses complete design, manufacture, supply/delivery, installation, start-up, and initial operational testing of the landfill gas blower/flare system at the facility located at 6030 West California Avenue. The work involves furnishing and installing all equipment, facilities, services, and appurtenances as indicated in the contract documents. The plans document provides the technical specifications and design requirements necessary for bidders to understand the physical layout, equipment specifications, and installation requirements for this infrastructure improvement at the solid waste management facility.
The document serves as a critical reference for contractors bidding on this project, detailing the engineering plans and technical requirements that must be adhered to during the equipment design, manufacturing, and installation phases. This plans document would be used in conjunction with other contract documents, including the scope of work and specifications, to provide bidders with comprehensive information needed to prepare accurate proposals and execute the project successfully.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALT LAKE CITY
CORPORATION
ENGINEERING DIVISION
SALT LAKE CITY
CORPORATION
COMMUNITY AND
NEIGHBORHOODS
I C
T Y
S A L
T L A K E
SLVSWMF
FLARE DESIGN
BASIS 40%
GENERAL
INFORMATION
SITE
ORIENTATION
MAP
GI 001
DRAFT
BLUE STAKES OF UTAH
Utility Notification Center, Inc.
1-800-662-4111 www.bluestakes.org
Dig Safely. Know what'sbelow.
Callbefore you dig.
CALL BEFORE YOU DIG.
SURVEY-BENCHMARK
SURVEY-STREET MONUMENT
BID ITEM
KEY NOTE
EXISTING STORM DRAIN
sd sd sd
AVERY HOLYOAK S.L.C. PROJECT ENGINEER
EMAIL: AVERY.HOLYOAK@SLC.GOV
PHONE: (801) 913-4946
LEON FORD S.L.V.S.W.M.F. OPERATIONS MANAGER
EMAIL: LFORD@SALTLAKECOUNTY.GOV
PHONE: (801) 381-8670
RELOCATION OF ANY UTILITY BOXES, MANHOLES, OR OTHER SURFACE UTILITIES, OTHER THAN RAISING THEM TO THE NEW GRADE, REQUIRES APPROVAL, OF THE NEW LOCATION, BY THE PROJECT INSPECTOR PRIOR TO REMOVING IT FROM ITS ORIGINAL LOCATION. COORDINATE WITH THE PROJECT INSPECTOR A MINIMUM OF 48
HOURS PRIOR TO DISTURBING FACILITIES IN ANY WAY.
GRAVEL
CONCRETE
EXISTING GAS CONTROL VALVE
PROPOSED GAS CONTROL VALVE
EXISTING GAS PIPELINE
G
PROPOSED POWER
P
PROPOSED CHAIN-LINK FENCE
EXISTING UNDERGROUND POWER
P-UG
EXISTING OVERHEAD POWER
P-OH
PROPOSED COMPRESSED AIRLINE
AIR
PROPOSED GAS PIPELINE
G
PROPOSED FLARE DRAIN LINE
FD
PROPOSED 24" STORM DRAIN
24-SD
PROPOSED CONTOUR LINES
EXISTING CONTOUR LINES
SALT LAKE CITY
CORPORATION
ENGINEERING DIVISION
SALT LAKE CITY
CORPORATION
COMMUNITY AND
NEIGHBORHOODS
I C
T Y
S A
L
T L A K
E
SLVSWMF
FLARE DESIGN
BASIS 40%
GENERAL
INFORMATION
LEGEND AND
GENERAL NOTES
GI 002
ENGINEERING DIVISION
SALT LAKE CITY
CORPORATION
COMMUNITY AND
NEIGHBORHOODS
I C
T Y
S A L
T L A K E
SLVSWMF
FLARE DESIGN
BASIS 40%
SITE
PLAN
EXISTING
CONDITIONS
SP 101
ENGINEERING DIVISION
SALT LAKE CITY
CORPORATION
COMMUNITY AND
NEIGHBORHOODS
I C
T Y
S A L
T L A K E
SLVSWMF
FLARE DESIGN
BASIS 40%
PROPOSED
PLAN
SP 102
ENGINEERING DIVISION
SALT LAKE CITY
CORPORATION
COMMUNITY AND
NEIGHBORHOODS
I C
T Y
S A L
T L A K E
SLVSWMF
FLARE DESIGN
BASIS 40%
GRADING
PROPOSED
GRADING
PLAN
GR 101
FD
P P
P
SALT LAKE CITY
CORPORATION
ENGINEERING DIVISION
SALT LAKE CITY
CORPORATION
COMMUNITY AND
NEIGHBORHOODS
I C
T Y
S A L
T L A K E
SLVSWMF
FLARE DESIGN
BASIS 40%
DETAILS
FLARE /
BLOWER STATION
DETAILS
DT 101
P
G
AIR
| SLVSWMF Design Basis 40% SLC Plan Set.pdf |
| Sheets and Views |
| Design Basis 40% SLC Plan Set - SE-COVER |
| Design Basis 40% SLC Plan Set - SE-GI 001 |
| Design Basis 40% SLC Plan Set - SE-GI 002 |
| Design Basis 40% SLC Plan Set - SE-SP 101 |
| Design Basis 40% SLC Plan Set - SE-SP 102 |
| Design Basis 40% SLC Plan Set - SE-GR 101 |
| Design Basis 40% SLC Plan Set - SE-DT 101 |
File details come from the government source that posted it. Updated .