4-Municipal Building Roof Replacement and PV Design Contract 2 Plans.pdf
PDF 9 MB Posted
- Attached to
- Request for Proposals for Capital Lease Financing of Township Vehicles and Equipment (Contract #C-26-001)
- Solicitation number
- Not on record
- Issued by
- Delaware County, Pennsylvania
About this file
This document is a comprehensive electrical design and specification set prepared by Spotts, Stevens & McCoy for a Municipal Building Roof Replacement and Photovoltaic (PV) Design Contract for Radnor Township in Delaware County, Pennsylvania. The project involves a complete roof replacement and solar photovoltaic system installation, with bid documents reissued multiple times (most recently on 08/21/25). The proposed solar system includes 186 Hanwha Q Cells Q.PEAK DUO XL-G11S 585W solar modules, six 17.3 kW SolarEdge inverters, and will generate a total DC system size of 108.81 kW with a total AC system size of 103.8 kW. The project also includes replacing existing lightning protection systems and making electrical infrastructure modifications.
The electrical design includes detailed specifications for mounting arrays across multiple roof sections, with six separate arrays utilizing power optimizers and interconnected strings of 20-22 modules. The system will connect to the existing 2000A main switchboard with a utility-accessible 400A disconnect switch. The project includes comprehensive labeling requirements, inverter trip settings, and adherence to multiple electrical codes and standards including NEC, NEMA, and IEEE regulations. The design incorporates specific requirements for conductor types, grounding methods, raceway installations, and equipment identification, with careful attention to mounting heights, support structures, and electrical safety protocols.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Copyright 2024 SPOTTS, STEVENS & MCCOY 102577.0004-G.0-00-M
INDEX TO DRAWINGS
DWG NO. DISCIPLINE DESCRIPTION
G.0-00 GENERAL COVER SHEET
E.0-01-M ELECTRICAL LEGEND AND SPECIFICATIONS
EP.D-01-M ELECTRICAL - POWER EXISTING ROOF PLAN
EP.D-02-M ELECTRICAL - POWER LIGHTNING PROTECTION
EXISTING ROOF PLAN
EP.1-01-M ELECTRICAL - POWER PROPOSED ROOF PLAN
EP.1-02-M ELECTRICAL - POWER LIGHTNING PROTECTION
PROPOSED ROOF PLAN
E.5-01-M ELECTRICAL SINGLE LINE DIAGRAM
LOCATION MAP
1047 North Park Road Reading, PA 19610-0307 610.621.2000
701 Creekside Lane Lititz, PA 17543 717.568.2678
Engineers and Consultants
SPOTTS, STEVENS & MCCOY
ssmgroup.com
READING
LANCASTER
Roma Corporate Center, Suite 106 1605 N Cedar Crest Blvd Allentown, PA 18104 610.849.9700
LEHIGH VALLEY
101 East Evans Street West Chester, PA 19380 610.621.2000
WEST CHESTER
08/21/25
BIDDING
REISSUED FOR
C O
PY
R
IG
H
T
S
PO
TT
S, S
TE
VE
N
S
M C
C O
Y
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
R
EL
EA
SE
D F
O R
PR
O
JE
C
T M
AN
AG
ER
D
AT
E:
N
.B
BA
SE
B Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
D
ES
C
R
IP
TI
O
N N
O
D
AT
E M
AD
E
C H
KD
AP
VD
C
H
EC
KE
D
B Y:
102577.0004
10/04/24
R
AD
N O
R T
O W
N
SH
IP
IV
EN
A
VE
N
U E, W
AY
N E, P A
R O
O F
R
EP
LA
C
EM
EN
T
AN
D P
V D
ES
IG
N
BI
D
PM
M
/2
N /A
N /A
/2 1/
IS
SU
ED
F O
R B
ID
M
LE
JM
T
JM
T
/2
3/
R
EI
SS
U
ED
F
O R
B
ID
TM
F
C M
F
JM
T
/2
1/
R
EI
SS
U
ED
F
O R
B
ID
TM
F
C M
F
JM
T N
O T
FO
R
C O
N
ST
R U
C
TI
O N
N or th P ar k
R oa d R ea di ng , P
A
-0
0.
1.
C re ek si de L an e
Li tit z, P
A
7.
8.
E ng in ee rs a nd C on su lta nt s
SP
O
TT
S, S
TE
VE
N S
M
C C
O Y ss m gr ou p.
co m
R E
A D
IN
G
L A
N C
A S
T E
R
R om a C or po ra te
C en te r, S ui te
N
C ed ar C re st
B lv d A lle nt ow n, P A
0.
9.
L E
H
IG
H V
A L
L E
Y
E as t E va ns S tre et
W es t C he st er
, P A
0.
1.
W E
S T
C H
E S
T E
R
CONTRACT 2
E.0-01-M
102577.0004
EP.0-01-M
EL
EC
TR
IC
AL
LE
G
EN
D A
N D
S
PE
C
IF
IC
AT
IO
N
S
TM
F
C
JC
SOLAR MODULE
SINGLE RECEPTACLE
DUPLEX RECEPTACLE
DUPLEX RECEPTACLE WITH INTEGRAL GROUND-FAULT CIRCUIT
INTERRUPTER PROTECTIONGF
I
DUPLEX RECEPTACLE WITH INTEGRAL GROUND-FAULT CIRCUIT
INTERRUPTER PROTECTION WITH COVER UL LISTED AS WEATHER-TIGHT
WHILE IN USE
W P
SPECIAL PURPOSE RECEPTACLE
TELEPHONE OUTLET
DATA OUTLET, TYPE AS INDICATED ON PLANS
COMBINATION DATA AND VOICE OUTLET, TYPE AS INDICATED ON PLANS
SURFACE MOUNTED LIGHTING AND APPLIANCE BRANCH CIRCUIT
PANELBOARD
SURFACE OR FLOOR MOUNTED DISTRIBUTION PANELBOARD
DISCONNECT SWITCH, TYPE AND SIZE AS INDICATED ON PLANS
MAGNETIC STARTER, SIZE AS INDICATED ON PLANS
WIRING CONCEALED ABOVE CEILINGS OR IN WALLS
WIRING CONCEALED UNDERGROUND
WIRING CONNECTED TO EMERGENCY POWER SOURCE
BRANCH CIRCUIT HOMERUN TO PANEL; NUMBER OF ARROWS INDICATES
NUMBER OF CIRCUITS, LETTER INDICATE PANEL DESIGNATION, NUMBERS
INDICATE CIRCUIT BREAKER POSITION
LP-5,6,7
ELECTRICAL LEGEND
DISCONNECT SWITCHES AND CIRCUIT BREAKERS: NOT MORE 6'-7" ABOVE FINISHED
FLOOR TO CENTER OF OPERATING HANDLE.
MOUNTING HEIGHTS
J PULLBOX/ JUNCTION BOX
CABLE TRAY
RACEWAY TURNING DOWN
CT
GROUND ROD
GROUND ROD/ TEST WELL
RACEWAY TURNING UP
SCOPE OF THE WORK
PROVIDE ALL WORK SHOWN ON THE DRAWINGS AND ADDENDA, INCLUDING INCIDENTAL WORK AND MATERIALS REQUIRED TO FULFILL THE INTENT OF THE DRAWINGS, INCLUDE LABOR, MATERIALS, DEVICES, CONTROLS, SUPPORTS, ANCHORS AND
METHODS PECULIAR TO THE EQUIPMENT OR SYSTEMS.
DEFINITIONS
PROVIDE: THIS CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE WITH ALL APPURTENANCE DEVICES, OPTIONS, FEATURES, AND SUPPORTS TO ASSURE A COMPLETE AND WORKING INSTALLATION IN ACCORDANCE WITH ALL APPLICABLE
CODES AND STANDARDS.
FURNISH: THIS CONTRACTOR SHALL OBTAIN AND DELIVER TO POINT OF INSTALLATION ON THE JOB FOR INSTALLATION BY
OTHER TRADES.
CODES AND STANDARDS
EQUIPMENT, SYSTEMS, MATERIALS, PRODUCTS AND INSTALLATIONS SHALL BE IN ACCORDANCE WITH PLANS, SPECIFICATIONS AND APPLICABLE REQUIREMENTS OF THE LATEST VERSIONS OF THE FOLLOWING:
1. NATIONAL ELECTRICAL CODE (NEC)
2. NATIONAL ELECTRICAL MANUFACTURERS' ASSOCIATION (NEMA)
3. INSULATED POWER CABLE ENGINEERS ASSOCIATION (IPCEA)
4. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)
5. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA)
6. AMERICANS WITH DISABILITIES ACT (ADA)
7. INTERNATIONAL BUILDING CODE (IBC)
8. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
9. NATIONAL FIRE PROTECTION ASSOCIATION; NATIONAL FIRE CODES (NFC)
10. UNDERWRITERS LABORATORIES (UL)
11. LOCAL CODES AND ORDINANCES
CONTRACTOR WARRANTS THAT HIS BID PRICE INCLUDES ALL LABOR, MATERIAL, PRODUCTS, EQUIPMENT, APPURTENANCES, DEVICES, ACCESSORIES, OPTIONS, SUPPORTS, AND METHODS TO PROVIDE A COMPLETE SYSTEM THAT COMPLIES WITH THE
CODES, ORDINANCES, LAWS AND REGULATIONS LISTED ABOVE.
PERMITS, TESTS, AND INSPECTIONS
OBTAIN PERMITS, PAY FEES, AND ISSUE NOTICES REQUIRED BY STATE AND LOCAL CODES, MUNICIPALITIES AND
AUTHORITIES HAVING JURISDICTION.
PROVIDE COPIES OF PERMITS, CERTIFICATES AND TEST REPORTS TO THE OWNER.
COORDINATION
COORDINATE WORK WITH THE VARIOUS TRADES TO ASSURE AN EFFICIENT AND ORDERLY SEQUENCE OF INSTALLATION AND
CONSTRUCTION.
UTILIZE SPACE EFFICIENTLY TO MAXIMIZE ACCESSIBILITY FOR OTHER INSTALLATIONS, FOR MAINTENANCE AND FOR REPAIRS.
IF CONTRACTOR INSTALLS WORK WITHOUT COORDINATING WITH OTHER TRADES, AND A CONFLICT OCCURS, CONTRACTOR WILL REMOVE THE WORK AND REINSTALL IT WITHOUT ADDITIONAL COSTS OR EXTENSIONS OF TIME.
EQUIPMENT
PROVIDE EQUIPMENT, ELECTRICAL COMPONENTS, DEVICES AND ACCESSORIES THAT ARE LISTED AND LABELED AS DEFINED
IN NFPA 70, ARTICLE 100, 690, AND 705.
EQUIPMENT SHALL BE INSTALLED AND START-UP PERFORMED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. THE CONTRACTOR SHALL OBTAIN INSTALLATION INSTRUCTIONS FROM THE MANUFACTURER PRIOR TO INSTALLING THE EQUIPMENT. INSTALLATION INSTRUCTIONS AND DIAGRAMS SHALL BECOME PART OF THE OPERATIONS AND
MAINTENANCE MANUALS.
PLANS AND SPECIFICATIONS
THE PLANS AND SPECIFICATIONS ARE BID DOCUMENTS, AND ARE FOR THE PURPOSE OF ILLUSTRATING THE GENERAL
CHARACTER AND SCOPE OF WORK FOR CONTRACTORS TO PREPARE A BID PROPOSAL.
THE PLANS ARE NOT SHOP DRAWINGS AND DO NOT DISMISS THE CONTRACTOR FROM THE RESPONSIBILITY OF
COORDINATING HIS WORK WITH THE WORK OF OTHER TRADES AND THE BUILDING STRUCTURE.
IN ADDITION TO THE WORK SHOWN ON THE DRAWINGS AND DESCRIBED IN SPECIFICATIONS, PROVIDE ALL INCIDENTAL WORK, LABOR, AND MATERIAL REQUIRED TO FULFILL THE INTENT OF THE PLANS AND SPECIFICATIONS.
PROTECTION OF THE WORK
PROTECT THE WORK, EQUIPMENT AND MATERIALS FROM DAMAGE, DUST, DIRT, DEBRIS, MOISTURE, CHEMICALS AND WATER.
EQUIPMENT AND CONDUIT OPENINGS SHALL BE PLUGGED, CAPPED OR COVERED DURING CONSTRUCTION.
AT CONTRACTOR'S EXPENSE, REPAIR OR REPLACE, WORK DAMAGED BY CONTRACTOR, TO THE SATISFACTION OF THE
OWNER.
WARRANTIES
UNLESS OTHERWISE NOTED, PROVIDE A ONE YEAR WARRANTY, FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER, ON
LABOR, EQUIPMENT, MATERIALS, PRODUCTS AND INSTALLATION.
MATERIALS, EQUIPMENT, AND INSTALLATION
CONDUCTORS AND CABLES
ALL CONDUCTOR RUNS SHALL BE CONTINUOUS. WRITTEN APPROVAL MUST BE OBTAINED BEFORE THE USE OF ANY
CONDUCTOR SPLICES.
COPPER CONDUCTORS: COMPLY WITH NEMA WC 70/ICEA S-95-658.
ALUMINUM CONDUCTORS: COMPLY WITH NEMA WC 70/ICEA S-95-658, ONLY AS INDICATED ON THE DRAWINGS.
CONDUCTOR INSULATION: COMPLY WITH NEMA WC 70/ICEA S-95-658 FOR TYPE THHN-2-THWN-2.
FEEDERS AND BRANCH CIRCUITS SHALL BE COPPER CONDUCTORS, STRANDED FOR NO. 8 AWG AND LARGER, STRANDED OF
SOLID FOR NO. 10 AWG AND SMALLER.
CONDUCTOR INSULATION AND MULTICONDUCTOR CABLE APPLICATIONS AND WIRING METHODS:
· EXPOSED FEEDERS: TYPE THHN-2-THWN-2, SINGLE CONDUCTORS IN RACEWAY
· EXPOSED BRANCH CIRCUITS, INCLUDING IN CRAWLSPACES: TYPE THHN-2-THWN-2, SINGLE CONDUCTORS IN RACEWAY.
COMPLETE RACEWAY INSTALLATION BETWEEN CONDUCTOR AND CABLE TERMINATION POINTS PRIOR TO PULLING CONDUCTORS AND CABLES. USE MANUFACTURER-APPROVED PULLING COMPOUND OR LUBRICANT WHERE NECESSARY;
COMPOUND USED MUST NOT DETERIORATE CONDUCTOR OR INSULATION. DO NOT EXCEED MANUFACTURER'S
RECOMMENDED MAXIMUM PULLING TENSIONS AND SIDEWALL PRESSURE VALUES.
USE PULLING MEANS, INCLUDING FISH TAPE, CABLE, ROPE, AND BASKET-WEAVE WIRE/CABLE GRIPS, THAT WILL NOT DAMAGE
CABLES OR RACEWAY.
INSTALL SPLICES AND TAPS THAT ARE COMPATIBLE WITH CONDUCTOR MATERIAL AND THAT POSSESS EQUIVALENT OR
BETTER MECHANICAL STRENGTH AND INSULATION RATINGS THAN UNSPLICED CONDUCTORS.
INSTALL WIRING AT OUTLETS WITH AT LEAST 12 INCHES OF SLACK CONDUCTOR AT EACH OUTLET.
INSTALL EXPOSED CABLES PARALLEL AND PERPENDICULAR TO SURFACES OF EXPOSED STRUCTURAL MEMBERS, AND
FOLLOW SURFACE CONTOURS WHERE POSSIBLE.
TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS ACCORDING TO MANUFACTURER'S PUBLISHED TORQUE-TIGHTENING VALUES. IF MANUFACTURER'S TORQUE VALUES ARE NOT INDICATED, USE THOSE SPECIFIED IN UL 486A-486B.
WIRING SHALL BE TORQUED PER DEVICE LISTING OR MANUFACTURER'S RECOMMENDATIONS. SUBCONTRACTOR SHALL
PROVIDE TORQUE MARKS AT ALL MECHANICAL WIRE TERMINATIONS.
MAKE SPLICES, TERMINATIONS, AND TAPS THAT ARE COMPATIBLE WITH CONDUCTOR MATERIAL AND THAT POSSESS EQUIVALENT OR BETTER MECHANICAL STRENGTH AND INSULATION RATINGS THAN UNSPLICED CONDUCTORS.
GROUNDING AND BONDING
INSULATED CONDUCTORS SHALL BE COPPER, WITH 600 VOLT GREEN INSULATION UNLESS OTHERWISE REQUIRED BY
APPLICABLE CODE OR AUTHORITY HAVING JURISDICTION.
BOLTED CONNECTORS FOR CONDUCTORS AND PIPES SHALL BE COPPER, PRESSURE TYPE WITH AT LEAST TWO BOLTS.
PROVIDE A DEDICATED, INSULATED GROUNDING CONDUCTOR IN EACH BRANCH CIRCUIT AND FEEDER, SIZED IN
ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE.
USE BOLTED CONNECTORS FOR PIPE AND EQUIPMENT GROUNDING CONDUCTOR TERMINATIONS.
BOND TOGETHER BUILDING STEEL, METALLIC WATER PIPING, METALLIC GAS PIPING, AND GROUNDING SYSTEM IN
ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE.
GROUNDING/BONDING BUSHINGS ARE REQUIRED ON ALL CONDUIT ENTERING/LEAVING BOXES.
RACEWAYS
ELECTRICAL METALLIC TUBING (EMT):ANSI C80.3, ZINC-COATED STEEL, WITH SET-SCREW OR COMPRESSION FITTINGS.
INTERMEDIATE METAL CONDUIT (IMC): ANSI C80.6, ZINC-COATED STEEL, WITH THREADED FITTINGS.
RIGID METAL CONDUIT (RMC): ANSI C80.1, ZINC-COATED STEEL WITH THREAD FITTINGS, RIGID GALVANIZED STEEL (RGS)
LIQUID-TITE FLEXIBLE METAL CONDUIT (LFMC): ZINC-COATED STEEL WITH SUNLIGHT AND OIL RESISTANT PLASTIC JACKET.
RIGID NON-METALLIC CONDUIT (RNC): NEMA TC 2, SCHEDULE 40 PVC, WITH NEMA TC3 FITTINGS.
RACEWAY FITTINGS: SPECIFICALLY DESIGNED FOR THE RACEWAY TYPE WITH WHICH USED.
USE THE FOLLOWING RACEWAYS FOR OUTDOOR INSTALLATIONS:
1. EXPOSED OUTDOOR BRANCH CIRCUITS AND FEEDERS: BUILDING WIRE IN RMC.
2. CONCEALED OUTDOOR BRANCH CIRCUITS AND FEEDERS: BUILDING WIRE IN RMC.
3. CONNECTION TO VIBRATING EQUIPMENT: BUILDING WIRE IN LFMC.
USE THE FOLLOWING RACEWAYS FOR INDOOR INSTALLATIONS:
1. EXPOSED FEEDERS AND BRANCH CIRCUITS: BUILDING WIRE IN EMT.
2. EXPOSED FEEDERS AND BRANCH CIRCUITS SUBJECT TO DAMAGE: BUILDING WIRE IN RMC.
3. CONNECTION TO VIBRATING EQUIPMENT: BUILDING WIRE IN FMC; EXCEPT IN WET OR DAMP LOCATIONS, USE LFMC.
4. FEEDERS OR BRANCH CIRCUITS IN DAMP OR WET LOCATIONS: BUILDING WIRE IN RMC.
CONCEAL RACEWAYS AND CABLES, UNLESS OTHERWISE INDICATED, WITHIN FINISHED WALLS, CEILINGS, AND FLOORS.
INSTALL RACEWAYS AND CABLES AT LEAST 6 INCHES AWAY FROM PARALLEL RUNS OF HOT WATER PIPES. LOCATE
HORIZONTAL RACEWAY RUNS ABOVE WATER PIPING.
USE TEMPORARY RACEWAY CAPS TO PREVENT FOREIGN MATTER FROM ENTERING.
MAKE CONDUIT BENDS AND OFFSETS SO ID IS NOT REDUCED. KEEP LEGS OF BENDS IN THE SAME PLANE AND STRAIGHT
LEGS OF OFFSETS PARALLEL, UNLESS OTHERWISE INDICATED.
USE RACEWAY AND CABLE FITTINGS COMPATIBLE WITH RACEWAYS AND CABLES AND SUITABLE FOR USE AND LOCATION.
INSTALL PULL WIRES IN EMPTY RACEWAYS. USE #14 AWG ZINC-COATED STEEL OR MONOFILAMENT PLASTIC LINE WITH NOT LESS THAN 200-LB TENSILE STRENGTH. LEAVE AT LEAST 12 INCHES OF SLACK AT EACH END OF THE PULL WIRE.
CONNECT MOTORS AND EQUIPMENT SUBJECT TO VIBRATION, NOISE TRANSMISSION, OR MOVEMENT WITH A MAXIMUM OF 72-INCH LFMC FLEXIBLE CONDUIT. INSTALL SEPARATE GROUND CONDUCTOR ACROSS FLEXIBLE CONNECTIONS.
MAINTAIN FIRE RATINGS OF WALLS, PARTITIONS, CEILINGS AND FLOORS AT RACEWAY AND CABLE PENETRATIONS. SEAL
WITH UL LISTED FIRESTOPPING MATERIALS
CONDUIT EXPANSION FITTINGS SHALL BE INSTALLED IN EACH CONDUIT RUN WHERE IT CROSSES A BUILDING EXPANSION
JOINT, OR WHERE A STRAIGHT RUN EXCEEDS 120'.
ALL CONDUITS SHALL ENTER ENCLOSURES FROM BELOW UNLESS SPECIFICALLY STATED OTHERWISE. WHERE TOP OR SIDE
ENTRY IS NECESSARY MYERS HUBS OR EQUIVALENT SHALL BE USED.
ZINC AND DIECAST CONDUIT FITTINGS ARE NOT PERMITTED.
CONDULET AND CONDUIT BODIES ARE APPROVED FOR DATA/COMMUNICATION RUNS ONLY.
BOXES
SHEET METAL OUTLET AND DEVICE BOXES: NEMA OS1
SUPPORTING DEVICES
MATERIAL: COLD-FORMED STEEL, WITH CORROSION-RESISTANT COATING ACCEPTABLE TO AUTHORITIES HAVING
JURISDICTION.
CHANNEL THICKNESS: SELECTED TO SUIT STRUCTURAL LOADING.
FITTINGS AND ACCESSORIES: PRODUCTS OF THE SAME MANUFACTURER AS CHANNEL SUPPORTS.
FITTINGS AND ACCESSORY MATERIALS: SAME AS CHANNELS AND ANGLES, EXCEPT METAL ITEMS MAY BE STAINLESS STEEL.
RACEWAY AND CABLE SUPPORTS: MANUFACTURED CLEVIS HANGERS, RISER CLAMPS, STRAPS, THREADED C-CLAMPS WITH RETAINERS, CEILING TRAPEZE HANGERS, WALL BRACKETS, AND SPRING-STEEL CLAMPS OR CLICK-TYPE HANGERS.
PIPE SLEEVES: ASTM A 53, TYPE E, GRADE A, SCHEDULE 40, GALVANIZED STEEL, PLAIN ENDS.
EXPANSION ANCHORS: CARBON-STEEL WEDGE OR SLEEVE TYPE.
DAMP LOCATIONS AND OUTDOORS: HOT-DIP GALVANIZED MATERIALS, U-CHANNEL SYSTEM COMPONENTS.
DRY LOCATIONS: STEEL MATERIALS.
SELECTION OF SUPPORTS: COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
STRENGTH OF SUPPORTS: ADEQUATE TO CARRY PRESENT AND FUTURE LOADS, TIMES A SAFETY FACTOR OF AT LEAST
FOUR; MINIMUM OF 200-LB DESIGN LOAD.
INSTALL SUPPORT DEVICES TO SECURELY AND PERMANENTLY FASTEN AND SUPPORT ELECTRICAL COMPONENTS.
INSTALL INDIVIDUAL AND MULTIPLE RACEWAY HANGERS TO SUPPORT RACEWAYS. PROVIDE U-BOLTS, CLAMPS, ATTACHMENTS, AND OTHER HARDWARE NECESSARY FOR HANGER ASSEMBLIES AND FOR SECURING HANGER RODS AND
CONDUITS.
SUPPORT PARALLEL RUNS OF HORIZONTAL RACEWAYS TOGETHER ON TRAPEZE OR BRACKET-TYPE HANGERS. SIZE SUPPORTS FOR MULTIPLE RACEWAY INSTALLATIONS SO CAPACITY CAN BE INCREASED BY 25 PERCENT MINIMUM IN THE
FUTURE.
SUPPORT SHEET-METAL BOXES DIRECTLY FROM THE BUILDING STRUCTURE OR BY BAR HANGERS. IF BAR HANGERS ARE USED, ATTACH BAR TO RACEWAYS ON OPPOSITE SIDES OF THE BOX AND SUPPORT THE RACEWAY WITH AN APPROVED
FASTENER NOT MORE THAN 24 INCHES FROM THE BOX.
INSTALL METAL CHANNEL RACKS FOR MOUNTING CABINETS, PANELBOARDS, PULL AND JUNCTION BOXES, AND OTHER DEVICES UNLESS THEY ARE MOUNTED DIRECTLY TO STRUCTURAL ELEMENTS OF ADEQUATE STRENGTH.
ALL MOUNTING HARDWARE SHALL BE STAINLESS STEEL OR GALVANIZED FOR PROTECTION FROM ENVIRONMENTAL
ELEMENTS.
CUT EDGES OF GALVANIZED MATERIALS SHALL BE COLD GALVANIZED AT THE TIME OF INSTALLATION. ALL STRUT USED FOR EQUIPMENT MOUNTING SHALL BE CUT AND SANDED FLUSH WITH GEAR PRIOR TO GALV TREATMENT.
PV SOLAR MODULE
DURING INSTALLATION, MODULE ELECTRICAL CONNECTORS SHALL BE PROTECTED FROM INTRUSION OF DUST, DIRT, WATER, SNOW AND ICE.
ELECTRICAL IDENTIFICATION NOTE LABELING REQUIREMENTS FROM NEC 690
ENGRAVED-PLASTIC LABELS, SIGNS, AND INSTRUCTION PLATES: ENGRAVING STOCK, MELAMINE PLASTIC LAMINATE PUNCHED OR DRILLED FOR MECHANICAL FASTENERS 1/16-INCH MINIMUM THICKNESS FOR SIGNS UP TO 20 SQ. IN. AND 1/8-INCH MINIMUM THICKNESS FOR LARGER SIZES. ENGRAVED LEGEND SHALL BE BLACK LETTERS ON WHITE BACKGROUND.
FASTENERS FOR NAMEPLATES AND SIGNS: SELF-TAPPING, STAINLESS-STEEL SCREWS OR NO. 10/32 STAINLESS-STEEL
MACHINE SCREWS WITH NUTS AND FLAT AND LOCK WASHERS.
INSTALL AT LOCATIONS FOR MOST CONVENIENT VIEWING WITHOUT INTERFERENCE WITH OPERATION AND MAINTENANCE OF
EQUIPMENT.
COLOR CODE SECONDARY SERVICE, FEEDER, AND BRANCH-CIRCUIT CONDUCTORS THROUGHOUT THE SECONDARY
ELECTRICAL SYSTEM AS FOLLOWS:
COLOR CODING OF INDIVIDUAL FEEDER CABLES SHALL MATCH THE SOURCE PANELBOARD.
COLORS FOR 208/120-V CIRCUITS:
a. PHASE A: BLACK.
b. PHASE B: RED.
c. PHASE C: BLUE.
COLORS FOR 240-V CIRCUITS:
a. PHASE A: BLACK.
b. PHASE B: RED.
COLORS FOR 480/277-V CIRCUITS:
c. PHASE A: BROWN.
d. PHASE B: ORANGE.
e. PHASE C: YELLOW.
INSTALL ENGRAVED-LAMINATED NAMEPLATES WITH WHITE LETTERS ON BLACK BACKGROUND WITH MINIMUM 3/8-INCH HIGH
LETTERING WITH EQUIPMENT DESIGNATION AND VOLTAGE.
WIRING DEVICES
CONVENIENCE RECEPTACLES: 125V, 20 AMP. COMPLY WITH NEMA WD1, NEMA WD6, CONFIGURATION 5-20R, AND UL 498.
FINISH AS SELECTED BY THE OWNER.
GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLES: STRAIGHT BLADE, NON-FEED THROUGH TYPE. COMPLY WITH NEMA WD1, NEMA WD6, UL498, AND UL493, CLASS A, AND INCLUDE INDICATOR LIGHT THAT IS LIGHTED WHEN DEVICE IS TRIPPED.
SWITCHES: 120/277 V, 20 AMPS, ROCKER TYPE. COMPLY WITH NEMA WD1, AND UL 20. FINISH AS SELECTED BY THE OWNER.
INSTALL GROUND PIN OF VERTICALLY ORIENTATED RECEPTACLES UP, AND ON HORIZONTALLY MOUNTED RECEPTACLES TO
THE RIGHT.
INSTALL COVER PLATES ON ALL WIRING DEVICES. GROUP ADJACENT DEVICES UNDER A COMMON COVER PLATE. WALL
PLATES SHALL BE BRUSHED STAINLESS STEEL, UNLESS NOTED OTHERWISE.
REPLACE ALL DEVICES THAT HAVE BEEN IN TEMPORARY USE DURING CONSTRUCTION.
INSTALL ALL WIRING DEVICES IN FINISHED SPACES FLUSH, UNLESS OTHERWISE NOTED.
PANELBOARDS
ENCLOSURES SHALL BE SURFACE AS INDICATED ON THE PLANS, NEMA TYPE 3R, MINIMUM UNLESS OTHERWISE NOTED.
BACKBOXES SHALL BE GALVANIZED STEEL. PANELS AND TRIM SHALL BE STEEL AND GALVANIZED STEEL, FACTORY FINISHED IMMEDIATELY AFTER CLEANING AND PRE-TREATING WITH MANUFACTURER'S STANDARD TWO-COAT, BAKED ENAMEL FINISH
CONSISTING OF PRIME COAT AND THERMOSETTING TOP COAT.
PHASE, NEUTRAL, AND GROUND BUSES SHALL BE HARD DRAWN COPPER, 98% CONDUCTIVITY.
INSTALL PANELBOARDS AND ACCESSORIES ACCORDING TO NECA 407.
MOUNT PANELBOARD CABINET PLUMB AND RIGID WITHOUT DISTORTION OF BOX.
INSTALL FILLER PLATES IN UNUSED OPENINGS.
CREATE A DIRECTORY TO INDICATE INSTALLED CIRCUIT LOADS AFTER BALANCING PANELBOARD LOADS; INCORPORATE OWNER'S FINAL ROOM DESIGNATIONS. OBTAIN APPROVAL BEFORE INSTALLING. USE A COMPUTER OR TYPEWRITER TO
CREATE DIRECTORY; HAND WRITTEN DIRECTORIES ARE NOT ACCEPTABLE.
LABEL EACH PANELBOARD WITH A NAMEPLATE COMPLYING WITH REQUIREMENTS FOR IDENTIFICATION SPECIFIED UNDER
"ELECTRICAL IDENTIFICATION" ABOVE.
LABEL EACH BRANCH CIRCUIT DEVICE IN DISTRIBUTION PANELBOARDS WITH A NAMEPLATE COMPLYING WITH REQUIREMENTS FOR IDENTIFICATION SPECIFIED UNDER "ELECTRICAL IDENTIFICATION" ABOVE.
DISCONNECT SWITCHES
FUSIBLE SWITCHES
1, TYPE HD, HEAVY DUTY, SINGLE THROW 600 V AC: UL 98 AND NEMA KS1, HORSEPOWER RATED, WITH CARTRIDGE FUSE
INTERIORS TO ACCOMMODATE INDICATED FUSES, LOCKABLE HANDLE WITH CAPABILITY TO ACCEPT TWO PAD LOCKS, INTERLOCKED WITH COVER IN CLOSED POSITION, AND WINDOWS TO VIEW VISIBLE BLADE IN OPEN AND CLOSED
POSITION.
NON-FUSIBLE SWITCHES
1. TYPE HD, HEAVY DUTY, SINGLE THROW, 600 V AC, 1200 A AND SMALLER: UL 98 AND NEMA KS 1, HORSEPOWER RATED, LOCKABLE HANDLE WITH CAPABILITY TO ACCEPT THREE PADLOCKS, INTERLOCKED WITH COVER IN CLOSED POSITION, AND WINDOWS TO VIEW VISIBLE BLADE IN OPEN AND CLOSED POSITION.
ACCESSORIES:PROVIDE EQUIPMENT GROUNDING KITS FOR ALL DISCONNECT SWITCHES.
APPLICATION AND INSTALLATION
IF MOUNTING HEIGHTS OR OTHER LOCATION CRITERIA ARE NOT INDICATED, ARRANGE AND INSTALL COMPONENTS AND
EQUIPMENT TO PROVIDE THE MAXIMUM POSSIBLE HEADROOM.
MATERIALS AND COMPONENTS: INSTALL LEVEL, PLUMB, AND PARALLEL AND PERPENDICULAR TO OTHER BUILDING SYSTEMS
AND COMPONENTS, UNLESS OTHERWISE INDICATED.
EQUIPMENT: INSTALL TO FACILITATE SERVICE, MAINTENANCE, AND REPAIR OR REPLACEMENT OF COMPONENTS. CONNECT
FOR EASE OF DISCONNECTING, WITH MINIMUM INTERFERENCE WITH OTHER INSTALLATIONS.
SECURITY
CAMERA (TYP.)
LOUVER (TYP. FOR 4)
2 1
C O
PY
R
IG
H
T
S
PO
TT
S, S
TE
VE
N
S
M C
C O
Y
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
R
EL
EA
SE
D F
O R
PR
O
JE
C
T M
AN
AG
ER
D
AT
E:
N
.B
BA
SE
B Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
D
ES
C
R
IP
TI
O
N N
O
D
AT
E M
AD
E
C H
KD
AP
VD
C
H
EC
KE
D
B Y:
102577.0004
10/04/24
R
AD
N O
R T
O W
N
SH
IP
IV
EN
A
VE
N
U E, W
AY
N E, P A
R O
O F
R
EP
LA
C
EM
EN
T
AN
D P
V D
ES
IG
N
BI
D
PM
M
/2
N /A
N /A
/2 1/
IS
SU
ED
F O
R B
ID
M
LE
JM
T
JM
T
/2
3/
R
EI
SS
U
ED
F
O R
B
ID
TM
F
C M
F
JM
T
/2
1/
R
EI
SS
U
ED
F
O R
B
ID
TM
F
C M
F
JM
T N
O T
FO
R
C O
N
ST
R U
C
TI
O N
N or th P ar k
R oa d R ea di ng , P
A
-0
0.
1.
C re ek si de L an e
Li tit z, P
A
7.
8.
E ng in ee rs a nd C on su lta nt s
SP
O
TT
S, S
TE
VE
N S
M
C C
O Y ss m gr ou p.
co m
R E
A D
IN
G
L A
N C
A S
T E
R
R om a C or po ra te
C en te r, S ui te
N
C ed ar C re st
B lv d A lle nt ow n, P A
0.
9.
L E
H
IG
H V
A L
L E
Y
E as t E va ns S tre et
W es t C he st er
, P A
0.
1.
W E
S T
C H
E S
T E
R
CONTRACT 2
SCALE: 18"=1'-0"
0'4' 4' 8' 12' 16' 20'
MUNICIPAL BUILDING - EXISTING ROOF PLAN
EP.D-01-M
102577.0004
EP.D-01-M
EL
EC
TR
IC
AL
PO
W
ER
M
U N
IC
IP
AL
B
U
IL
D
IN
G
EX
IS
TI
N
G R
O O
F
PL
AN
TM
F
C
JC
KEYED NOTES
REMOVE EXISTING WIRE AND CONDUIT TO NEW JUNCTION BOX TO BE MOUNTED WITHIN
CEILING SPACE BELOW AND SAFE-OFF FOR REUSE. EXTEND WIRE AND CONDUIT AS REQUIRED
TO NEW RTU. ELECTRICAL CONTRACTOR SHALL CONFIRM NEW RTU ELECTRICAL MATCHES
EXISTING ONE. IF IT DOES NOT ELECTRICAL CONTRACTOR SHALL INFORM THE ENGINEERS.
REMOVE EXISTING WIRE AND CONDUIT TO NEW JUNCTION BOX TO BE MOUNTED WITHIN
CEILING SPACE BELOW AND SAFE-OFF FOR REUSE. EXTEND WIRE AND CONDUIT AS REQUIRED
TO NEW ERU. ELECTRICAL CONTRACTOR SHALL CONFIRM NEW ERU ELECTRICAL MATCHES
EXISTING ONE. IF IT DOES NOT ELECTRICAL CONTRACTOR SHALL INFORM THE ENGINEERS.
LIGHTENING
ARRESTOR (TYP.)
LIGHTENING
ARRESTOR (TYP.)
C O
PY
R
IG
H
T
S
PO
TT
S, S
TE
VE
N
S
M C
C O
Y
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
R
EL
EA
SE
D F
O R
PR
O
JE
C
T M
AN
AG
ER
D
AT
E:
N
.B
BA
SE
B Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
D
ES
C
R
IP
TI
O
N N
O
D
AT
E M
AD
E
C H
KD
AP
VD
C
H
EC
KE
D
B Y:
102577.0004
10/04/24
R
AD
N O
R T
O W
N
SH
IP
IV
EN
A
VE
N
U E, W
AY
N E, P A
R O
O F
R
EP
LA
C
EM
EN
T
AN
D P
V D
ES
IG
N
BI
D
PM
M
/2
N /A
N /A
/2 1/
IS
SU
ED
F O
R B
ID
M
LE
JM
T
JM
T
/2
3/
R
EI
SS
U
ED
F
O R
B
ID
TM
F
C M
F
JM
T
/2
1/
R
EI
SS
U
ED
F
O R
B
ID
TM
F
C M
F
JM
T N
O T
FO
R
C O
N
ST
R U
C
TI
O N
N or th P ar k
R oa d R ea di ng , P
A
-0
0.
1.
C re ek si de L an e
Li tit z, P
A
7.
8.
E ng in ee rs a nd C on su lta nt s
SP
O
TT
S, S
TE
VE
N S
M
C C
O Y ss m gr ou p.
co m
R E
A D
IN
G
L A
N C
A S
T E
R
R om a C or po ra te
C en te r, S ui te
N
C ed ar C re st
B lv d A lle nt ow n, P A
0.
9.
L E
H
IG
H V
A L
L E
Y
E as t E va ns S tre et
W es t C he st er
, P A
0.
1.
W E
S T
C H
E S
T E
R
CONTRACT 2
SCALE: 18"=1'-0"
0'4' 4' 8' 12' 16' 20'
LIGHTNING PROTECTION
MUNICIPAL BUILDING - EXISTING ROOF PLAN
EP.D-02-M
102577.0004
EP.D-02-M
EL
EC
TR
IC
AL
PO
W
ER
LI
G H
TN
IN
G P
R O
TE
C
TI
O
N
M U
N
IC
IP
AL
B U
IL
D
IN
G
EX
IS
TI
N G
R O
O F
PL
AN
TM
F
C
JC
REMOVAL NOTES
REMOVE EXISTING LIGHTNING CONDUCTORS, ARRESTORS,
AND APPURTENANCES ON ROOF TO BE REPLACED.
MDP-1
INVERTER
UTILITY ACCESSIBLE
DISCONNECT SWITCH
1-120
1-220 2-120
2-220
3-120
3-220
4-122
5-122
6-122
SECURITY
CAMERA (TYP.)
LOUVER (TYP. FOR 4)
2 1
PANEL 'MDP'
PANEL 'MDA'
PANEL 'RPB'
(SECT. 2)
UPS
2000A
DIST.
'MDP'
MAIN
CIRCUIT
BREAKER
UTILITY
COMP.ATS
#1
ATS
#2
ATS
#3
PANEL 'EDP'
PANEL 'EPM'
PANEL 'RPG'
GENERATOR
PANEL 'RPB'
(SECT. 1)
EF 3.1
ELEC. ROOM
GENERATOR
ROOM
CORRIDOR
C O
PY
R
IG
H
T
S
PO
TT
S, S
TE
VE
N
S
M C
C O
Y
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
R
EL
EA
SE
D F
O R
PR
O
JE
C
T M
AN
AG
ER
D
AT
E:
N
.B
BA
SE
B Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
D
ES
C
R
IP
TI
O
N N
O
D
AT
E M
AD
E
C H
KD
AP
VD
C
H
EC
KE
D
B Y:
102577.0004
10/04/24
R
AD
N O
R T
O W
N
SH
IP
IV
EN
A
VE
N
U E, W
AY
N E, P A
R O
O F
R
EP
LA
C
EM
EN
T
AN
D P
V D
ES
IG
N
BI
D
PM
M
/2
N /A
N /A
/2 1/
IS
SU
ED
F O
R B
ID
M
LE
JM
T
JM
T
/2
3/
R
EI
SS
U
ED
F
O R
B
ID
TM
F
C M
F
JM
T
/2
1/
R
EI
SS
U
ED
F
O R
B
ID
TM
F
C M
F
JM
T N
O T
FO
R
C O
N
ST
R U
C
TI
O N
N or th P ar k
R oa d R ea di ng , P
A
-0
0.
1.
C re ek si de L an e
Li tit z, P
A
7.
8.
E ng in ee rs a nd C on su lta nt s
SP
O
TT
S, S
TE
VE
N S
M
C C
O Y ss m gr ou p.
co m
R E
A D
IN
G
L A
N C
A S
T E
R
R om a C or po ra te
C en te r, S ui te
N
C ed ar C re st
B lv d A lle nt ow n, P A
0.
9.
L E
H
IG
H V
A L
L E
Y
E as t E va ns S tre et
W es t C he st er
, P A
0.
1.
W E
S T
C H
E S
T E
R
CONTRACT 2
SCALE: 18"=1'-0"
0'4' 4' 8' 12' 16' 20'
MUNICIPAL BUILDING - PROPOSED ROOF PLAN
EP.1-01-M
102577.0004
EP.1-01-M
EL
EC
TR
IC
L
- P
O W
ER
M
U N
IC
IP
AL
B
U
IL
D
IN
G
PR
O
PO
SE
D P
LA
N
S
SCALE: 14"=1'-0"
4' 8'0' 4'
MUNICIPAL BUILIDNG
PARTIAL GROUND FLOOR PLANGENERAL NOTE:
PROPOSED ROOF PLAN INDICATES BASIS OF DESIGN
LAYOUT FOR THE PV MODULES, ETC INDICATED ON THE
EQUIPMENT SPECIFICATIONS AND SCHEDULES ON
DRAWING E.5-01-M.
SUBSTITUTIONS AND ANY CHANGE IN PANEL SIZE, RATING,
ETC FOR AN EQUIVALENT ARRAY OUTPUT SHALL INCLUDE
AN UPDATED PROPOSED ROOF PLAN INDICATING THE
REVISED ARRAY FOOTPRINT AND SETBACKS AT ROOF
EDGE, OBSTRUCTIONS, ETC.
LIGHTENING
ARRESTOR (TYP.)
LIGHTENING
ARRESTOR (TYP.)
C O
PY
R
IG
H
T
S
PO
TT
S, S
TE
VE
N
S
M C
C O
Y
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
R
EL
EA
SE
D F
O R
PR
O
JE
C
T M
AN
AG
ER
D
AT
E:
N
.B
BA
SE
B Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
D
ES
C
R
IP
TI
O
N N
O
D
AT
E M
AD
E
C H
KD
AP
VD
C
H
EC
KE
D
B Y:
102577.0004
10/04/24
R
AD
N O
R T
O W
N
SH
IP
IV
EN
A
VE
N
U E, W
AY
N E, P A
R O
O F
R
EP
LA
C
EM
EN
T
AN
D P
V D
ES
IG
N
BI
D
PM
M
/2
N /A
N /A
/2 1/
IS
SU
ED
F O
R B
ID
M
LE
JM
T
JM
T
/2
3/
R
EI
SS
U
ED
F
O R
B
ID
TM
F
C M
F
JM
T
/2
1/
R
EI
SS
U
ED
F
O R
B
ID
TM
F
C M
F
JM
T N
O T
FO
R
C O
N
ST
R U
C
TI
O N
N or th P ar k
R oa d R ea di ng , P
A
-0
0.
1.
C re ek si de L an e
Li tit z, P
A
7.
8.
E ng in ee rs a nd C on su lta nt s
SP
O
TT
S, S
TE
VE
N S
M
C C
O Y ss m gr ou p.
co m
R E
A D
IN
G
L A
N C
A S
T E
R
R om a C or po ra te
C en te r, S ui te
N
C ed ar C re st
B lv d A lle nt ow n, P A
0.
9.
L E
H
IG
H V
A L
L E
Y
E as t E va ns S tre et
W es t C he st er
, P A
0.
1.
W E
S T
C H
E S
T E
R
CONTRACT 2
SCALE: 18"=1'-0"
0'4' 4' 8' 12' 16' 20'
LIGHTNING PROTECTION
MUNICIPAL BUILDING - PROPOSED ROOF PLAN
EP.1-02-M
102577.0004
EP.1-02-M
EL
EC
TR
IC
L
- P
O W
ER
LI
G H
TN
IN
G P
R O
TE
C
TI
O
N
M U
N
IC
IP
AL
B U
IL
D
IN
G
PR
O
PO
SE
D
P
LA
N S
INSTALLATION NOTES
PROVIDE NEW LIGHTNING PROTECTION SYSTEM INCLUDING CONDUCTORS,
ARRESTORS, AND ALL APPURTENANCES. PROVIDE ADDITIONAL LIGHTNING
PROTECTION SYSTEM DEVICES AS NECESSARY IN ORDER TO OBTAIN A UL
MASTER LABEL CERTIFICATE UPON COMPLETION.
UTILITY ACCESSIBLE
DISCONNECT SWITCH
400A
NEMA 3R
LOCKABLE, VISIBLE BLADE
INV.
#4
INV.
#3
INV.
#2
ARRAY 1
2 STRINGS
OF 10 PV
OPTIMIZERS
W/ 2
MODULES
PER STRING
INV.
#1
60A-3P
MDP-1 INVERTER COMBINER PANEL
400 AMP 208Y/120V-3Ø, 4W, - NEMA 3R
ARRAY 6
1 STRING
OF 11 PV
OPTIMIZERS
W/ 2
MODULES
PER STRING
INV.
#6
INV.
#5
400A-3P
60A-3P 60A-3P 60A-3P 60A-3P 60A-3P
ARRAY 2
2 STRINGS
OF 10 PV
OPTIMIZERS
W/ 2
MODULES
PER STRING
ARRAY 3
2 STRINGS
OF 10 PV
OPTIMIZERS
W/ 2
MODULES
PER STRING
ARRAY 4
1 STRINGS
OF 11 PV
OPTIMIZERS
W/ 2
MODULES
PER STRING
ARRAY 5
1 STRINGS
OF 11 PV
OPTIMIZERS
W/ 2
MODULES
PER STRING
400A-3P
2 #10 1000 VDC PV
WIRE - 1 #8G (TYP.)2
(TYP.)
(TYP.)
60A-3P AC DISC. (TYP.)
DC DISC. UNIT (TYP.)
INVERTER POWER
PACK (TYP.)
1-1/4" PVC SCH 40 - 3 #4, 1 #10
& 1 #10G, CU, THWN-2
(TYPICAL)
(2) 4" C - 4 #500KCMIL,
& 1 #1/0G, CU, THWN-2
M
PECO METER
SERIAL #017112749
2000A
90A-3P30A-3P
FOUNTAIN
PUMPTVSS
EXISTING MAIN SWITCHBOARD
2000 AMP 208/120V-3Ø, 4W, 65KAIC
POW-R-LINE SWITCHBOARD
G.O. NO. SPH83255
EXISTING PAD MOUNTED
TRANSFORMER
EXISTING
UNDERGROUND
CABLE
600A-3P
PANEL
MPA
60A-3P600A-3P
ATS #1PANEL
MPC
200A-3P125A-3P125A-3P175A-3P
ELEVATORPANEL
RPG
PANEL
RPBATS #2
125A-3P
PANEL
MDP
400A-3P
PANEL
MP8
150A-3P
PANEL
RPE
200A-3P
ATS #3
175A-3P
PANEL
RPC
175A-3P
UPS
125A-3P
PANEL
RPA
SPACE SPACE SPACE
1 2 1 2 1 2 1 2 1 2 1 2
3 3 3 3 3 3
P1101
POWER OPTIMIZER
PV
MODULE
PV
MODULE
NEXT POWER OPTIMIZER AND
PAIR OF PV MODULES IN STRING
PREVIOUS POWER OPTIMIZER AND
PAIR OF PV MODULES IN STRING
1 1
M
PECO METER
SERIAL #017112749
2000A
90A-3P30A-3P
FOUNTAIN
PUMPTVSS
EXISTING MAIN SWITCHBOARD
2000 AMP 208/120V-3Ø, 4W, 65KAIC
POW-R-LINE SWITCHBOARD
G.O. NO. SPH83255
EXISTING PAD MOUNTED
TRANSFORMER
EXISTING
UNDERGROUND
CABLE
600A-3P
PANEL
MPA
60A-3P600A-3P
ATS #1PANEL
MPC
200A-3P125A-3P125A-3P175A-3P
ELEVATORPANEL
RPG
PANEL
RPBATS #2
125A-3P
PANEL
MDP
400A-3P
PANEL
MP8
150A-3P
PANEL
RPE
200A-3P
ATS #3
175A-3P
PANEL
RPC
175A-3P
UPS
125A-3P
PANEL
RPA
SPACE SPACE SPACE
C O
PY
R
IG
H
T
S
PO
TT
S, S
TE
VE
N
S
M C
C O
Y
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
DIGITAL FILENAMEDATE
WORK ORDER NUMBER
DRAWING NUMBER
R
EL
EA
SE
D F
O R
PR
O
JE
C
T M
AN
AG
ER
D
AT
E:
N
.B
BA
SE
B Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
D
ES
C
R
IP
TI
O
N N
O
D
AT
E M
AD
E
C H
KD
AP
VD
C
H
EC
KE
D
B Y:
102577.0004
10/04/24
R
AD
N O
R T
O W
N
SH
IP
IV
EN
A
VE
N
U E, W
AY
N E, P A
R O
O F
R
EP
LA
C
EM
EN
T
AN
D P
V D
ES
IG
N
BI
D
PM
M
/2
N /A
N /A
/2 1/
IS
SU
ED
F O
R B
ID
M
LE
JM
T
JM
T
/2
3/
R
EI
SS
U
ED
F
O R
B
ID
TM
F
C M
F
JM
T
/2
1/
R
EI
SS
U
ED
F
O R
B
ID
TM
F
C M
F
JM
T N
O T
FO
R
C O
N
ST
R U
C
TI
O N
N or th P ar k
R oa d R ea di ng , P
A
-0
0.
1.
C re ek si de L an e
Li tit z, P
A
7.
8.
E ng in ee rs a nd C on su lta nt s
SP
O
TT
S, S
TE
VE
N S
M
C C
O Y ss m gr ou p.
co m
R E
A D
IN
G
L A
N C
A S
T E
R
R om a C or po ra te
C en te r, S ui te
N
C ed ar C re st
B lv d A lle nt ow n, P A
0.
9.
L E
H
IG
H V
A L
L E
Y
E as t E va ns S tre et
W es t C he st er
, P A
0.
1.
W E
S T
C H
E S
T E
R
CONTRACT 2
EP.5-01-M
102577.0004
EP.5-01-M
EL
EC
TR
IC
AL
SI
N G
LE
L
IN
E
D
IA
G R
AM
C
JC
C
JC
NO SCALE
SINGLE LINE DIAGRAM
CONNECT NUMBER OF PV STRINGS AS INDICATED TO INVERTER. EACH PV STRING CONSISTS OF 20 OR 22 PV
MODULES CONNECTED IN SERIES.
PROVIDE COPPER #10 AWG PV WIRE, TYPE PV, RATED AT 1000 VOLTS, CIRCUIT TO THE GROUP OF 20 OR 22 PV MODULES CONNECTED IN SERIES FOR THE STRING AND CIRCUIT EACH OF THE NUMBER OF STRINGS INDICATED TO THE INVERTER CONNECTION UNIT. CONNECT THE #8 AWG GROUND WIRE FROM THE INVERTER GROUND TO THE RACKING SYSTEM GROUND CONNECTION POINT FOR EACH PV ARRAY. PROVIDE #8 AWG GROUND WIRE TO
INTERCONNECT SEPARATE RACKING SYSTEMS WITHIN EACH PV ARRAY.
PROVIDE NEW 400A/3P BREAKER IN EXISTING 4X FILLER SPACE LOCATED BELOW EXISTING BREAKERS.
NOTES:
INVERTER TRIP SETTINGS TABLE
PROTECTIVE ELEMENT EVENT TYPICAL SETTINGS THRESHOLD TIME (SEC)
27 UNDER-VOLTAGE
27-1 0.50 pu V (104 VOLTS) 0.16
27-2 0.88 pu V (183 VOLTS) 2.00
59 OVER-VOLTAGE
59-1 1.20 pu V (250 VOLTS) 0.16
59-2 1.10 pu V (228.8 VOLTS) 1.00
81o OVER-FREQUENCY 81O-1 60.5 Hz 0.16
81u UNDER-FREQUENCY 81U-1 57.0 Hz 0.16
LABELS
AC SYSTEM RATING - 690.54
ALL INTERACTIVE SYSTEM(S) POINTS OF
CONNECTION WITH OTHER SOURCES -
INVERTER OUTPUT CONNECTION AT AC
DISCONNECTS AND SERVICE PANEL DOOR
WARNING THIS PANEL HAS SECONDARY
POWER SOURCE FROM PHOTOVOLTAIC
SYSTEM. TURN-OFF PHOTOVOLTAIC
SYSTEM BREAKER PRIOR TO SERVICING
PANEL. MAX AC OUTPUT CURRENT: XXX.X
AMPS OPERATING AC VOLTAGE XXXV
OPEN CIRCUIT VOLTAGE
DC DISCONNECTS - 690.17
WARNING ELECTRIC SHOCK HAZARD. DO
NOT TOUCH TERMINALS. TERMINALS ON
BOTH LINE AND LOAD SIDES MAY BE
ENERGIZED IN THE OPEN POSITION.
EQUIPMENT SCHEDULE
PART NO. NAME QUANTITY DESCRIPTION
1 PV MODULE 186 585 W MODULES 1000VDC
2 P1101 POWER OPTIMIZER 93 SOLAREDGE P1101 POWER OPTIMIZER
3 17 KW INVERTER 6 17 KW INVERTER, SOLAREDGE
4 MDP-1 INVERTER COMBINER PANEL 1 208/120 VAC, 3ɸ, 4W, 400A MCB DISTRIBUTION PANEL, NEMA 3R
5 UTILITY ACCESSIBLE DISCONNECT 1 208/120 VAC, 3ɸ, 4W, 400A, VISIBLE BLADE, LOCKABLE, VIEWING
WINDOW,
PV SYSTEM SUMMARY
SYSTEM ROOF MOUNTED
PV MODULE MODEL (QUANTITY) HANWHA Q CELLS, Q.PEAK DUO
XL-G11S 585 (183)
PV MODULE STC DC RATING 585 W
PV MODULES PER SOURCE CIRCUIT
(STRING) 20-22
TOTAL PV MODULE COUNT 186
TOTAL STC DC SYSTEM SIZE 108.81 KW
TOTAL AC SYSTEM SIZE 103.8 KW
DC/AC RATIO 1.05
INVERTER MODEL (QUANTITY) SOLAREDGE SE17.3KUS (6)
PECO CONTACT INFORMATION:
ACCOUNT #:
METER #: 017112749
EQUIPMENT SPECIFICATIONS
PHOTOVOLTAIC SOLAR MODULE
(PANEL) - HANWHA Q CELLS, Q.PEAK
DUO XL-G11S 585 (585W)
585 W
MAXIMUM POWER P_max 585 W
MAXIMUM POWER CURRENT I_mp 12.97 A
SHORT CIRCUIT CURRENT I_sc 13.57 A
OPEN CIRCUIT VOLTAGE V_oc 53.59 V
INVERTER -
SOLAREDGE SE17.3KUS 17.3 KW
MAXIMUM POWER OUTPUT 17,300 W
PEAK POWER TRACKING (MPPT) 370-600V
DC MAXIMUM VOLTAGE 600V
OUTPUT VOLTAGE RANGE 105-229V
OUTPUT VOLTAGE 208/120 VAC
AC MAXIMUM AMPERAGE 48.25A
CEC EFFICIENCY 97.5%
GENERAL NOTE:
ELECTRICAL CONTRACTOR SHALL BE
RESPONSIBLE FOR SUBMISSION OF UTILITY
INTERCONNECTION APPLICATION.
GENERAL NOTE:
PROPOSED SINGLE LINE, EQUIPMENT SPECIFICATIONS AND
EQUIPMENT SCHEDULES INDICATE THE BASIS OF DESIGN FOR
THE PV ARRAY.
SUBSTITUTIONS SHALL BE PROVIDED AS FOR REVIEW BY THE
ENGINEER OF RECORD ACCORDING TO SPECIFICATION
SECTION
012500 - "SUBSTITUTION PROCEDURES." ANY SUBSTITUTIONS
SHALL RESULT IN AN EQUIVALENT ARRAY OUTPUT.
| Sheets and Views |
| G.0-00-M-contract 2 |
| E.0-01-M |
| EP.D-01-M |
| EP.D-02-M |
| EP.1-01-M |
| EP.1-02-M |
| E.5-01-M |
File details come from the government source that posted it. Updated .