3-Public Works Complex Roof Replacement and PV Design Contract 2 Plans.pdf

PDF 9 MB Posted

Attached to
Request for Proposals for Capital Lease Financing of Township Vehicles and Equipment (Contract #C-26-001)
Solicitation number
Not on record
Issued by
Delaware County, Pennsylvania

About this file

This document is a comprehensive set of electrical design drawings and specifications for a Public Works Complex Roof Replacement and Photovoltaic (PV) Design project for Radnor Township in Delaware County, Pennsylvania, prepared by Spotts, Stevens & McCoy (SSM). The project involves installing a roof replacement and a solar photovoltaic system across multiple buildings, including a Garage & Office Building and a North Shed. The proposed solar array will consist of 323 Hanwha Q Cells Q.Peak Duo XL-G11S 585W solar modules, totaling 188.96 kW DC system size and 173 kW AC system size, with 10 SolarEdge SE17.3KUS inverters. The project is currently out for bidding, with the most recent bid documents reissued on 08/21/2025.

The electrical design includes detailed single-line diagrams showing the interconnection of solar arrays, inverters, and existing electrical infrastructure, with specific focus on integrating the new PV system with the township's existing electrical distribution panels. The system will connect to the PECO utility grid, with a DC/AC ratio of 1.09 and provisions for proper grounding, disconnects, and labeling as per electrical codes. The project specifications outline rigorous requirements for installation, including conductor types, raceway specifications, grounding protocols, and equipment mounting standards. The design emphasizes coordination between trades, compliance with national electrical standards, and the provision of a complete, functional solar power generation system that meets the township's energy needs.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Copyright 2024 SPOTTS, STEVENS & MCCOY 102577.0004-G.0-00-PW

INDEX TO DRAWINGS

DWG NO. DISCIPLINE DESCRIPTION

G.0-00 GENERAL COVER SHEET

G.1-01-PW GENERAL SITE PLAN

E.0-01-PW ELECTRICAL LEGEND AND SPECIFICATIONS

E.1-01-PW ELECTRICAL - POWER GARAGE & OFFICE BUILDING AND BREAK ROOM BUILDING -

PROPOSED PLANS

E.1-02-PW ELECTRICAL - POWER NORTH SHED - PROPOSED PLANS

E.5-01-PW ELECTRICAL SINGLE LINE DIAGRAM

LOCATION MAP

1047 North Park Road Reading, PA 19610-0307 610.621.2000

701 Creekside Lane Lititz, PA 17543 717.568.2678

Engineers and Consultants

SPOTTS, STEVENS & MCCOY

ssmgroup.com

READING

LANCASTER

Roma Corporate Center, Suite 106 1605 N Cedar Crest Blvd Allentown, PA 18104 610.849.9700

LEHIGH VALLEY

101 East Evans Street West Chester, PA 19380 610.621.2000

WEST CHESTER

08/21/2025

BIDDING

REISSUED FOR

Kr om er

R oa d

Radnor Township Public Works Dept.

ELECTRICAL

ROOM

(2) 4" POWER

(2) 2" CONTROL

(2) 4" POWER

A

A

B B

APPROXIMATELY 55'

APPROXIMATELY 9'

STUB CONDUITS UP IN THE

MIDDLE BETWEEN THE

TWO DOORS

STUB CONDUITS UP AT

EXTERIOR OF WALL

STUB CONDUITS UP AT

EXTERIOR OF WALL NEXT

TO MAN DOOR

APPROXIMATELY 9'

FINISHED GRADE

" M

IN

BACKFILL

CAUTION TAPE

12" BFG

2" PVC CONDUIT

CLEAN COMPACTED

BACKFILL

3"

4" PVC CONDUIT

CONCRETE

4" COVER

NEW ASPHALT FINISHED GRADE

4"

3"

FINISHED GRADE

" M

IN

BACKFILL

CAUTION TAPE

12" BFG

2" PVC CONDUIT

CONCRETE

4" COVER

CLEAN COMPACTED

BACKFILL

3"

4" PVC CONDUIT

NEW ASPHALT FINISHED GRADE

4"

C O

PY

R

IG

H

T

S

PO

TT

S, S

TE

VE

N

S

M C

C O

Y

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

R

EL

EA

SE

D F

O R

PR

O

JE

C

T M

AN

AG

ER

D

AT

E:

N

.B

BA

SE

B Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

D

ES

C

R

IP

TI

O

N N

O

D

AT

E M

AD

E

C H

KD

AP

VD

C

H

EC

KE

D

B Y:

102577.0004

10/04/24

R

AD

N O

R T

O W

N

SH

IP

IV

EN

A

VE

N

U E, W

AY

N E, P A

R O

O F

R

EP

LA

C

EM

EN

T

AN

D P

V D

ES

IG

N

BI

D

PM

M

/2

N /A

N /A

/2 1/

IS

SU

ED

F O

R B

ID

M

LE

JM

T

JM

T

/2

3/

R

EI

SS

U

ED

F

O R

B

ID

TM

F

C M

F

JM

T

/2

1/

R

EI

SS

U

ED

F

O R

B

ID

TM

F

C M

F

JM

T N

O T

FO

R

C O

N

ST

R U

C

TI

O N

N or th P ar k

R oa d R ea di ng , P

A

-0

0.

1.

C re ek si de L an e

Li tit z, P

A

7.

8.

E ng in ee rs a nd C on su lta nt s

SP

O

TT

S, S

TE

VE

N S

M

C C

O Y ss m gr ou p.

co m

R E

A D

IN

G

L A

N C

A S

T E

R

R om a C or po ra te

C en te r, S ui te

N

C ed ar C re st

B lv d A lle nt ow n, P A

0.

9.

L E

H

IG

H V

A L

L E

Y

E as t E va ns S tre et

W es t C he st er

, P A

0.

1.

W E

S T

C H

E S

T E

R

CONTRACT 2

G.1-01-PW

102577.0004

G.1-01-PW

G

EN

ER

AL

PU

BL

IC

W

O R

KS

SI

TE

P

LA

N

SS

M

C

JC

SA

N

10' 0' 10' 20'5'

SCALE: 1"=10'

SITE PLAN

NO SCALE

TRENCH SECTION A-A

UNDERGROUND UTILITY NOTES:

1. EXISTING UTILITIES SHOWN ON THE PLAN HAVE BEEN DEVELOPED FROM RECENT SURVEY AND GPR SERVICES.

COMPLETENESS OR ACCURACY OF LOCATION AND DEPTH OF UNDERGROUND UTILITIES OR STRUCTURES CANNOT BE GUARANTEED. THE CONTRACTOR(S) IS (ARE) REPONSIBLE TO CONTACT EACH UTILITY COMPANY OR AUTHORITY AT LEAST THREE (3) DAYS BEFORE ANY EXCAVATION OF EXISTING UTILITIES. CONTRACTOR WILL BE REQUIRED TO REPAIR ALL DAMAGE UTILITY LINES. THE CONTRACTOR IS RESPONSIBLE TO OBTAIN ALL

REQUIRED MUNICIPAL PERMITS.

2. PURSUANT TO PA ACT 121 (2008), NOTIFICATION TO THE “ONE-CALL SYSTEM” IS REQUIRED AT LEAST THREE (3) WORKING DAYS PRIOR TO DISTURBING EARTH WITH ANY TYPE OF POWERED EQUIPMENT. CALL 1-800-242-1776.

REFER TO UTILITY NOTES, THIS SHEET.

NO SCALE

TRENCH SECTION B-B

REFER TO UTILITY NOTES, THIS SHEET.

WORK SCOPE SHOWN ON THIS SHEET SHALL BE

PRIORITIZED AS CRITICAL PATH AND IS TO BE COMPLETED

PRIOR TO ALL WORK INCLUDED IN THIS CONTRACT. WORK

IS OUT OF SCOPE AND SHOWN FOR REFERENCE ONLY.

WORK IS SHOWN FOR COORDINATION WITH CONTRACTOR

WORKING UNDER SEPARATE CONTRACT.

C O

PY

R

IG

H

T

S

PO

TT

S, S

TE

VE

N

S

M C

C O

Y

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

R

EL

EA

SE

D F

O R

PR

O

JE

C

T M

AN

AG

ER

D

AT

E:

N

.B

BA

SE

B Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

D

ES

C

R

IP

TI

O

N N

O

D

AT

E M

AD

E

C H

KD

AP

VD

C

H

EC

KE

D

B Y:

102577.0004

10/04/24

R

AD

N O

R T

O W

N

SH

IP

IV

EN

A

VE

N

U E, W

AY

N E, P A

R O

O F

R

EP

LA

C

EM

EN

T

AN

D P

V D

ES

IG

N

BI

D

PM

M

/2

N /A

N /A

/2 1/

IS

SU

ED

F O

R B

ID

M

LE

JM

T

JM

T

/2

3/

R

EI

SS

U

ED

F

O R

B

ID

TM

F

C M

F

JM

T

/2

1/

R

EI

SS

U

ED

F

O R

B

ID

TM

F

C M

F

JM

T N

O T

FO

R

C O

N

ST

R U

C

TI

O N

N or th P ar k

R oa d R ea di ng , P

A

-0

0.

1.

C re ek si de L an e

Li tit z, P

A

7.

8.

E ng in ee rs a nd C on su lta nt s

SP

O

TT

S, S

TE

VE

N S

M

C C

O Y ss m gr ou p.

co m

R E

A D

IN

G

L A

N C

A S

T E

R

R om a C or po ra te

C en te r, S ui te

N

C ed ar C re st

B lv d A lle nt ow n, P A

0.

9.

L E

H

IG

H V

A L

L E

Y

E as t E va ns S tre et

W es t C he st er

, P A

0.

1.

W E

S T

C H

E S

T E

R

CONTRACT 2

E.0-01-PW

102577.0004

EP.0-01-PW

EL

EC

TR

IC

AL

LE

G

EN

D A

N D

S

PE

C

IF

IC

AT

IO

N

S

TM

F

C

JC

SOLAR MODULE

SINGLE RECEPTACLE

DUPLEX RECEPTACLE

DUPLEX RECEPTACLE WITH INTEGRAL GROUND-FAULT CIRCUIT

INTERRUPTER PROTECTIONGF

I

DUPLEX RECEPTACLE WITH INTEGRAL GROUND-FAULT CIRCUIT

INTERRUPTER PROTECTION WITH COVER UL LISTED AS WEATHER-TIGHT

WHILE IN USE

W P

SPECIAL PURPOSE RECEPTACLE

TELEPHONE OUTLET

DATA OUTLET, TYPE AS INDICATED ON PLANS

COMBINATION DATA AND VOICE OUTLET, TYPE AS INDICATED ON PLANS

SURFACE MOUNTED LIGHTING AND APPLIANCE BRANCH CIRCUIT

PANELBOARD

SURFACE OR FLOOR MOUNTED DISTRIBUTION PANELBOARD

DISCONNECT SWITCH, TYPE AND SIZE AS INDICATED ON PLANS

MAGNETIC STARTER, SIZE AS INDICATED ON PLANS

WIRING CONCEALED ABOVE CEILINGS OR IN WALLS

WIRING CONCEALED UNDERGROUND

WIRING CONNECTED TO EMERGENCY POWER SOURCE

BRANCH CIRCUIT HOMERUN TO PANEL; NUMBER OF ARROWS INDICATES

NUMBER OF CIRCUITS, LETTER INDICATE PANEL DESIGNATION, NUMBERS

INDICATE CIRCUIT BREAKER POSITION

LP-5,6,7

ELECTRICAL LEGEND

DISCONNECT SWITCHES AND CIRCUIT BREAKERS: NOT MORE 6'-7" ABOVE FINISHED

FLOOR TO CENTER OF OPERATING HANDLE.

MOUNTING HEIGHTS

J PULLBOX/ JUNCTION BOX

CABLE TRAY

RACEWAY TURNING DOWN

CT

GROUND ROD

GROUND ROD/ TEST WELL

RACEWAY TURNING UP

SCOPE OF THE WORK

PROVIDE ALL WORK SHOWN ON THE DRAWINGS AND ADDENDA, INCLUDING INCIDENTAL WORK AND MATERIALS REQUIRED TO FULFILL THE INTENT OF THE DRAWINGS, INCLUDE LABOR, MATERIALS, DEVICES, CONTROLS, SUPPORTS, ANCHORS AND

METHODS PECULIAR TO THE EQUIPMENT OR SYSTEMS.

DEFINITIONS

PROVIDE: THIS CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE WITH ALL APPURTENANCE DEVICES, OPTIONS, FEATURES, AND SUPPORTS TO ASSURE A COMPLETE AND WORKING INSTALLATION IN ACCORDANCE WITH ALL APPLICABLE

CODES AND STANDARDS.

FURNISH: THIS CONTRACTOR SHALL OBTAIN AND DELIVER TO POINT OF INSTALLATION ON THE JOB FOR INSTALLATION BY

OTHER TRADES.

CODES AND STANDARDS

EQUIPMENT, SYSTEMS, MATERIALS, PRODUCTS AND INSTALLATIONS SHALL BE IN ACCORDANCE WITH PLANS, SPECIFICATIONS AND APPLICABLE REQUIREMENTS OF THE LATEST VERSIONS OF THE FOLLOWING:

1. NATIONAL ELECTRICAL CODE (NEC)

2. NATIONAL ELECTRICAL MANUFACTURERS' ASSOCIATION (NEMA)

3. INSULATED POWER CABLE ENGINEERS ASSOCIATION (IPCEA)

4. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)

5. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA)

6. AMERICANS WITH DISABILITIES ACT (ADA)

7. INTERNATIONAL BUILDING CODE (IBC)

8. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

9. NATIONAL FIRE PROTECTION ASSOCIATION; NATIONAL FIRE CODES (NFC)

10. UNDERWRITERS LABORATORIES (UL)

11. LOCAL CODES AND ORDINANCES

CONTRACTOR WARRANTS THAT HIS BID PRICE INCLUDES ALL LABOR, MATERIAL, PRODUCTS, EQUIPMENT, APPURTENANCES, DEVICES, ACCESSORIES, OPTIONS, SUPPORTS, AND METHODS TO PROVIDE A COMPLETE SYSTEM THAT COMPLIES WITH THE

CODES, ORDINANCES, LAWS AND REGULATIONS LISTED ABOVE.

PERMITS, TESTS, AND INSPECTIONS

OBTAIN PERMITS, PAY FEES, AND ISSUE NOTICES REQUIRED BY STATE AND LOCAL CODES, MUNICIPALITIES AND

AUTHORITIES HAVING JURISDICTION.

PROVIDE COPIES OF PERMITS, CERTIFICATES AND TEST REPORTS TO THE OWNER.

COORDINATION

COORDINATE WORK WITH THE VARIOUS TRADES TO ASSURE AN EFFICIENT AND ORDERLY SEQUENCE OF INSTALLATION AND

CONSTRUCTION.

UTILIZE SPACE EFFICIENTLY TO MAXIMIZE ACCESSIBILITY FOR OTHER INSTALLATIONS, FOR MAINTENANCE AND FOR REPAIRS.

IF CONTRACTOR INSTALLS WORK WITHOUT COORDINATING WITH OTHER TRADES, AND A CONFLICT OCCURS, CONTRACTOR WILL REMOVE THE WORK AND REINSTALL IT WITHOUT ADDITIONAL COSTS OR EXTENSIONS OF TIME.

EQUIPMENT

PROVIDE EQUIPMENT, ELECTRICAL COMPONENTS, DEVICES AND ACCESSORIES THAT ARE LISTED AND LABELED AS DEFINED

IN NFPA 70, ARTICLE 100, 690, AND 705.

EQUIPMENT SHALL BE INSTALLED AND START-UP PERFORMED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. THE CONTRACTOR SHALL OBTAIN INSTALLATION INSTRUCTIONS FROM THE MANUFACTURER PRIOR TO INSTALLING THE EQUIPMENT. INSTALLATION INSTRUCTIONS AND DIAGRAMS SHALL BECOME PART OF THE OPERATIONS AND

MAINTENANCE MANUALS.

PLANS AND SPECIFICATIONS

THE PLANS AND SPECIFICATIONS ARE BID DOCUMENTS, AND ARE FOR THE PURPOSE OF ILLUSTRATING THE GENERAL

CHARACTER AND SCOPE OF WORK FOR CONTRACTORS TO PREPARE A BID PROPOSAL.

THE PLANS ARE NOT SHOP DRAWINGS AND DO NOT DISMISS THE CONTRACTOR FROM THE RESPONSIBILITY OF

COORDINATING HIS WORK WITH THE WORK OF OTHER TRADES AND THE BUILDING STRUCTURE.

IN ADDITION TO THE WORK SHOWN ON THE DRAWINGS AND DESCRIBED IN SPECIFICATIONS, PROVIDE ALL INCIDENTAL WORK, LABOR, AND MATERIAL REQUIRED TO FULFILL THE INTENT OF THE PLANS AND SPECIFICATIONS.

PROTECTION OF THE WORK

PROTECT THE WORK, EQUIPMENT AND MATERIALS FROM DAMAGE, DUST, DIRT, DEBRIS, MOISTURE, CHEMICALS AND WATER.

EQUIPMENT AND CONDUIT OPENINGS SHALL BE PLUGGED, CAPPED OR COVERED DURING CONSTRUCTION.

AT CONTRACTOR'S EXPENSE, REPAIR OR REPLACE, WORK DAMAGED BY CONTRACTOR, TO THE SATISFACTION OF THE

OWNER.

WARRANTIES

UNLESS OTHERWISE NOTED, PROVIDE A ONE YEAR WARRANTY, FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER, ON

LABOR, EQUIPMENT, MATERIALS, PRODUCTS AND INSTALLATION.

MATERIALS, EQUIPMENT, AND INSTALLATION

CONDUCTORS AND CABLES

ALL CONDUCTOR RUNS SHALL BE CONTINUOUS. WRITTEN APPROVAL MUST BE OBTAINED BEFORE THE USE OF ANY

CONDUCTOR SPLICES.

COPPER CONDUCTORS: COMPLY WITH NEMA WC 70/ICEA S-95-658.

ALUMINUM CONDUCTORS: COMPLY WITH NEMA WC 70/ICEA S-95-658, ONLY AS INDICATED ON THE DRAWINGS.

CONDUCTOR INSULATION: COMPLY WITH NEMA WC 70/ICEA S-95-658 FOR TYPE THHN-2-THWN-2.

FEEDERS AND BRANCH CIRCUITS SHALL BE COPPER CONDUCTORS, STRANDED FOR NO. 8 AWG AND LARGER, STRANDED OF

SOLID FOR NO. 10 AWG AND SMALLER.

CONDUCTOR INSULATION AND MULTICONDUCTOR CABLE APPLICATIONS AND WIRING METHODS:

· EXPOSED FEEDERS: TYPE THHN-2-THWN-2, SINGLE CONDUCTORS IN RACEWAY

· EXPOSED BRANCH CIRCUITS, INCLUDING IN CRAWLSPACES: TYPE THHN-2-THWN-2, SINGLE CONDUCTORS IN RACEWAY.

COMPLETE RACEWAY INSTALLATION BETWEEN CONDUCTOR AND CABLE TERMINATION POINTS PRIOR TO PULLING CONDUCTORS AND CABLES. USE MANUFACTURER-APPROVED PULLING COMPOUND OR LUBRICANT WHERE NECESSARY;

COMPOUND USED MUST NOT DETERIORATE CONDUCTOR OR INSULATION. DO NOT EXCEED MANUFACTURER'S

RECOMMENDED MAXIMUM PULLING TENSIONS AND SIDEWALL PRESSURE VALUES.

USE PULLING MEANS, INCLUDING FISH TAPE, CABLE, ROPE, AND BASKET-WEAVE WIRE/CABLE GRIPS, THAT WILL NOT DAMAGE

CABLES OR RACEWAY.

INSTALL SPLICES AND TAPS THAT ARE COMPATIBLE WITH CONDUCTOR MATERIAL AND THAT POSSESS EQUIVALENT OR

BETTER MECHANICAL STRENGTH AND INSULATION RATINGS THAN UNSPLICED CONDUCTORS.

INSTALL WIRING AT OUTLETS WITH AT LEAST 12 INCHES OF SLACK CONDUCTOR AT EACH OUTLET.

INSTALL EXPOSED CABLES PARALLEL AND PERPENDICULAR TO SURFACES OF EXPOSED STRUCTURAL MEMBERS, AND

FOLLOW SURFACE CONTOURS WHERE POSSIBLE.

TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS ACCORDING TO MANUFACTURER'S PUBLISHED TORQUE-TIGHTENING VALUES. IF MANUFACTURER'S TORQUE VALUES ARE NOT INDICATED, USE THOSE SPECIFIED IN UL 486A-486B.

WIRING SHALL BE TORQUED PER DEVICE LISTING OR MANUFACTURER'S RECOMMENDATIONS. SUBCONTRACTOR SHALL

PROVIDE TORQUE MARKS AT ALL MECHANICAL WIRE TERMINATIONS.

MAKE SPLICES, TERMINATIONS, AND TAPS THAT ARE COMPATIBLE WITH CONDUCTOR MATERIAL AND THAT POSSESS EQUIVALENT OR BETTER MECHANICAL STRENGTH AND INSULATION RATINGS THAN UNSPLICED CONDUCTORS.

GROUNDING AND BONDING

INSULATED CONDUCTORS SHALL BE COPPER, WITH 600 VOLT GREEN INSULATION UNLESS OTHERWISE REQUIRED BY

APPLICABLE CODE OR AUTHORITY HAVING JURISDICTION.

BOLTED CONNECTORS FOR CONDUCTORS AND PIPES SHALL BE COPPER, PRESSURE TYPE WITH AT LEAST TWO BOLTS.

PROVIDE A DEDICATED, INSULATED GROUNDING CONDUCTOR IN EACH BRANCH CIRCUIT AND FEEDER, SIZED IN

ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE.

USE BOLTED CONNECTORS FOR PIPE AND EQUIPMENT GROUNDING CONDUCTOR TERMINATIONS.

BOND TOGETHER BUILDING STEEL, METALLIC WATER PIPING, METALLIC GAS PIPING, AND GROUNDING SYSTEM IN

ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE.

GROUNDING/BONDING BUSHINGS ARE REQUIRED ON ALL CONDUIT ENTERING/LEAVING BOXES.

RACEWAYS

ELECTRICAL METALLIC TUBING (EMT):ANSI C80.3, ZINC-COATED STEEL, WITH SET-SCREW OR COMPRESSION FITTINGS.

INTERMEDIATE METAL CONDUIT (IMC): ANSI C80.6, ZINC-COATED STEEL, WITH THREADED FITTINGS.

RIGID METAL CONDUIT (RMC): ANSI C80.1, ZINC-COATED STEEL WITH THREAD FITTINGS, RIGID GALVANIZED STEEL (RGS)

LIQUID-TITE FLEXIBLE METAL CONDUIT (LFMC): ZINC-COATED STEEL WITH SUNLIGHT AND OIL RESISTANT PLASTIC JACKET.

RIGID NON-METALLIC CONDUIT (RNC): NEMA TC 2, SCHEDULE 40 PVC, WITH NEMA TC3 FITTINGS.

RACEWAY FITTINGS: SPECIFICALLY DESIGNED FOR THE RACEWAY TYPE WITH WHICH USED.

USE THE FOLLOWING RACEWAYS FOR OUTDOOR INSTALLATIONS:

1. EXPOSED OUTDOOR BRANCH CIRCUITS AND FEEDERS: BUILDING WIRE IN RMC.

2. CONCEALED OUTDOOR BRANCH CIRCUITS AND FEEDERS: BUILDING WIRE IN RMC.

3. CONNECTION TO VIBRATING EQUIPMENT: BUILDING WIRE IN LFMC.

USE THE FOLLOWING RACEWAYS FOR INDOOR INSTALLATIONS:

1. EXPOSED FEEDERS AND BRANCH CIRCUITS: BUILDING WIRE IN EMT.

2. EXPOSED FEEDERS AND BRANCH CIRCUITS SUBJECT TO DAMAGE: BUILDING WIRE IN RMC.

3. CONNECTION TO VIBRATING EQUIPMENT: BUILDING WIRE IN FMC; EXCEPT IN WET OR DAMP LOCATIONS, USE LFMC.

4. FEEDERS OR BRANCH CIRCUITS IN DAMP OR WET LOCATIONS: BUILDING WIRE IN RMC.

CONCEAL RACEWAYS AND CABLES, UNLESS OTHERWISE INDICATED, WITHIN FINISHED WALLS, CEILINGS, AND FLOORS.

INSTALL RACEWAYS AND CABLES AT LEAST 6 INCHES AWAY FROM PARALLEL RUNS OF HOT WATER PIPES. LOCATE

HORIZONTAL RACEWAY RUNS ABOVE WATER PIPING.

USE TEMPORARY RACEWAY CAPS TO PREVENT FOREIGN MATTER FROM ENTERING.

MAKE CONDUIT BENDS AND OFFSETS SO ID IS NOT REDUCED. KEEP LEGS OF BENDS IN THE SAME PLANE AND STRAIGHT

LEGS OF OFFSETS PARALLEL, UNLESS OTHERWISE INDICATED.

USE RACEWAY AND CABLE FITTINGS COMPATIBLE WITH RACEWAYS AND CABLES AND SUITABLE FOR USE AND LOCATION.

INSTALL PULL WIRES IN EMPTY RACEWAYS. USE #14 AWG ZINC-COATED STEEL OR MONOFILAMENT PLASTIC LINE WITH NOT LESS THAN 200-LB TENSILE STRENGTH. LEAVE AT LEAST 12 INCHES OF SLACK AT EACH END OF THE PULL WIRE.

CONNECT MOTORS AND EQUIPMENT SUBJECT TO VIBRATION, NOISE TRANSMISSION, OR MOVEMENT WITH A MAXIMUM OF 72-INCH LFMC FLEXIBLE CONDUIT. INSTALL SEPARATE GROUND CONDUCTOR ACROSS FLEXIBLE CONNECTIONS.

MAINTAIN FIRE RATINGS OF WALLS, PARTITIONS, CEILINGS AND FLOORS AT RACEWAY AND CABLE PENETRATIONS. SEAL

WITH UL LISTED FIRESTOPPING MATERIALS

CONDUIT EXPANSION FITTINGS SHALL BE INSTALLED IN EACH CONDUIT RUN WHERE IT CROSSES A BUILDING EXPANSION

JOINT, OR WHERE A STRAIGHT RUN EXCEEDS 120'.

ALL CONDUITS SHALL ENTER ENCLOSURES FROM BELOW UNLESS SPECIFICALLY STATED OTHERWISE. WHERE TOP OR SIDE

ENTRY IS NECESSARY MYERS HUBS OR EQUIVALENT SHALL BE USED.

ZINC AND DIECAST CONDUIT FITTINGS ARE NOT PERMITTED.

CONDULET AND CONDUIT BODIES ARE APPROVED FOR DATA/COMMUNICATION RUNS ONLY.

BOXES

SHEET METAL OUTLET AND DEVICE BOXES: NEMA OS1

SUPPORTING DEVICES

MATERIAL: COLD-FORMED STEEL, WITH CORROSION-RESISTANT COATING ACCEPTABLE TO AUTHORITIES HAVING

JURISDICTION.

CHANNEL THICKNESS: SELECTED TO SUIT STRUCTURAL LOADING.

FITTINGS AND ACCESSORIES: PRODUCTS OF THE SAME MANUFACTURER AS CHANNEL SUPPORTS.

FITTINGS AND ACCESSORY MATERIALS: SAME AS CHANNELS AND ANGLES, EXCEPT METAL ITEMS MAY BE STAINLESS STEEL.

RACEWAY AND CABLE SUPPORTS: MANUFACTURED CLEVIS HANGERS, RISER CLAMPS, STRAPS, THREADED C-CLAMPS WITH RETAINERS, CEILING TRAPEZE HANGERS, WALL BRACKETS, AND SPRING-STEEL CLAMPS OR CLICK-TYPE HANGERS.

PIPE SLEEVES: ASTM A 53, TYPE E, GRADE A, SCHEDULE 40, GALVANIZED STEEL, PLAIN ENDS.

EXPANSION ANCHORS: CARBON-STEEL WEDGE OR SLEEVE TYPE.

DAMP LOCATIONS AND OUTDOORS: HOT-DIP GALVANIZED MATERIALS, U-CHANNEL SYSTEM COMPONENTS.

DRY LOCATIONS: STEEL MATERIALS.

SELECTION OF SUPPORTS: COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.

STRENGTH OF SUPPORTS: ADEQUATE TO CARRY PRESENT AND FUTURE LOADS, TIMES A SAFETY FACTOR OF AT LEAST

FOUR; MINIMUM OF 200-LB DESIGN LOAD.

INSTALL SUPPORT DEVICES TO SECURELY AND PERMANENTLY FASTEN AND SUPPORT ELECTRICAL COMPONENTS.

INSTALL INDIVIDUAL AND MULTIPLE RACEWAY HANGERS TO SUPPORT RACEWAYS. PROVIDE U-BOLTS, CLAMPS, ATTACHMENTS, AND OTHER HARDWARE NECESSARY FOR HANGER ASSEMBLIES AND FOR SECURING HANGER RODS AND

CONDUITS.

SUPPORT PARALLEL RUNS OF HORIZONTAL RACEWAYS TOGETHER ON TRAPEZE OR BRACKET-TYPE HANGERS. SIZE SUPPORTS FOR MULTIPLE RACEWAY INSTALLATIONS SO CAPACITY CAN BE INCREASED BY 25 PERCENT MINIMUM IN THE

FUTURE.

SUPPORT SHEET-METAL BOXES DIRECTLY FROM THE BUILDING STRUCTURE OR BY BAR HANGERS. IF BAR HANGERS ARE USED, ATTACH BAR TO RACEWAYS ON OPPOSITE SIDES OF THE BOX AND SUPPORT THE RACEWAY WITH AN APPROVED

FASTENER NOT MORE THAN 24 INCHES FROM THE BOX.

INSTALL METAL CHANNEL RACKS FOR MOUNTING CABINETS, PANELBOARDS, PULL AND JUNCTION BOXES, AND OTHER DEVICES UNLESS THEY ARE MOUNTED DIRECTLY TO STRUCTURAL ELEMENTS OF ADEQUATE STRENGTH.

ALL MOUNTING HARDWARE SHALL BE STAINLESS STEEL OR GALVANIZED FOR PROTECTION FROM ENVIRONMENTAL

ELEMENTS.

CUT EDGES OF GALVANIZED MATERIALS SHALL BE COLD GALVANIZED AT THE TIME OF INSTALLATION. ALL STRUT USED FOR EQUIPMENT MOUNTING SHALL BE CUT AND SANDED FLUSH WITH GEAR PRIOR TO GALV TREATMENT.

PV SOLAR MODULE

DURING INSTALLATION, MODULE ELECTRICAL CONNECTORS SHALL BE PROTECTED FROM INTRUSION OF DUST, DIRT, WATER, SNOW AND ICE.

ELECTRICAL IDENTIFICATION NOTE LABELING REQUIREMENTS FROM NEC 690

ENGRAVED-PLASTIC LABELS, SIGNS, AND INSTRUCTION PLATES: ENGRAVING STOCK, MELAMINE PLASTIC LAMINATE PUNCHED OR DRILLED FOR MECHANICAL FASTENERS 1/16-INCH MINIMUM THICKNESS FOR SIGNS UP TO 20 SQ. IN. AND 1/8-INCH MINIMUM THICKNESS FOR LARGER SIZES. ENGRAVED LEGEND SHALL BE BLACK LETTERS ON WHITE BACKGROUND.

FASTENERS FOR NAMEPLATES AND SIGNS: SELF-TAPPING, STAINLESS-STEEL SCREWS OR NO. 10/32 STAINLESS-STEEL

MACHINE SCREWS WITH NUTS AND FLAT AND LOCK WASHERS.

INSTALL AT LOCATIONS FOR MOST CONVENIENT VIEWING WITHOUT INTERFERENCE WITH OPERATION AND MAINTENANCE OF

EQUIPMENT.

COLOR CODE SECONDARY SERVICE, FEEDER, AND BRANCH-CIRCUIT CONDUCTORS THROUGHOUT THE SECONDARY

ELECTRICAL SYSTEM AS FOLLOWS:

COLOR CODING OF INDIVIDUAL FEEDER CABLES SHALL MATCH THE SOURCE PANELBOARD.

COLORS FOR 208/120-V CIRCUITS:

a. PHASE A: BLACK.

b. PHASE B: RED.

c. PHASE C: BLUE.

COLORS FOR 240-V CIRCUITS:

a. PHASE A: BLACK.

b. PHASE B: RED.

COLORS FOR 480/277-V CIRCUITS:

c. PHASE A: BROWN.

d. PHASE B: ORANGE.

e. PHASE C: YELLOW.

INSTALL ENGRAVED-LAMINATED NAMEPLATES WITH WHITE LETTERS ON BLACK BACKGROUND WITH MINIMUM 3/8-INCH HIGH

LETTERING WITH EQUIPMENT DESIGNATION AND VOLTAGE.

WIRING DEVICES

CONVENIENCE RECEPTACLES: 125V, 20 AMP. COMPLY WITH NEMA WD1, NEMA WD6, CONFIGURATION 5-20R, AND UL 498.

FINISH AS SELECTED BY THE OWNER.

GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLES: STRAIGHT BLADE, NON-FEED THROUGH TYPE. COMPLY WITH NEMA WD1, NEMA WD6, UL498, AND UL493, CLASS A, AND INCLUDE INDICATOR LIGHT THAT IS LIGHTED WHEN DEVICE IS TRIPPED.

SWITCHES: 120/277 V, 20 AMPS, ROCKER TYPE. COMPLY WITH NEMA WD1, AND UL 20. FINISH AS SELECTED BY THE OWNER.

INSTALL GROUND PIN OF VERTICALLY ORIENTATED RECEPTACLES UP, AND ON HORIZONTALLY MOUNTED RECEPTACLES TO

THE RIGHT.

INSTALL COVER PLATES ON ALL WIRING DEVICES. GROUP ADJACENT DEVICES UNDER A COMMON COVER PLATE. WALL

PLATES SHALL BE BRUSHED STAINLESS STEEL, UNLESS NOTED OTHERWISE.

REPLACE ALL DEVICES THAT HAVE BEEN IN TEMPORARY USE DURING CONSTRUCTION.

INSTALL ALL WIRING DEVICES IN FINISHED SPACES FLUSH, UNLESS OTHERWISE NOTED.

PANELBOARDS

ENCLOSURES SHALL BE SURFACE AS INDICATED ON THE PLANS, NEMA TYPE 3R, MINIMUM UNLESS OTHERWISE NOTED.

BACKBOXES SHALL BE GALVANIZED STEEL. PANELS AND TRIM SHALL BE STEEL AND GALVANIZED STEEL, FACTORY FINISHED IMMEDIATELY AFTER CLEANING AND PRE-TREATING WITH MANUFACTURER'S STANDARD TWO-COAT, BAKED ENAMEL FINISH

CONSISTING OF PRIME COAT AND THERMOSETTING TOP COAT.

PHASE, NEUTRAL, AND GROUND BUSES SHALL BE HARD DRAWN COPPER, 98% CONDUCTIVITY.

INSTALL PANELBOARDS AND ACCESSORIES ACCORDING TO NECA 407.

MOUNT PANELBOARD CABINET PLUMB AND RIGID WITHOUT DISTORTION OF BOX.

INSTALL FILLER PLATES IN UNUSED OPENINGS.

CREATE A DIRECTORY TO INDICATE INSTALLED CIRCUIT LOADS AFTER BALANCING PANELBOARD LOADS; INCORPORATE OWNER'S FINAL ROOM DESIGNATIONS. OBTAIN APPROVAL BEFORE INSTALLING. USE A COMPUTER OR TYPEWRITER TO

CREATE DIRECTORY; HAND WRITTEN DIRECTORIES ARE NOT ACCEPTABLE.

LABEL EACH PANELBOARD WITH A NAMEPLATE COMPLYING WITH REQUIREMENTS FOR IDENTIFICATION SPECIFIED UNDER

"ELECTRICAL IDENTIFICATION" ABOVE.

LABEL EACH BRANCH CIRCUIT DEVICE IN DISTRIBUTION PANELBOARDS WITH A NAMEPLATE COMPLYING WITH REQUIREMENTS FOR IDENTIFICATION SPECIFIED UNDER "ELECTRICAL IDENTIFICATION" ABOVE.

DISCONNECT SWITCHES

FUSIBLE SWITCHES

1, TYPE HD, HEAVY DUTY, SINGLE THROW 600 V AC: UL 98 AND NEMA KS1, HORSEPOWER RATED, WITH CARTRIDGE FUSE

INTERIORS TO ACCOMMODATE INDICATED FUSES, LOCKABLE HANDLE WITH CAPABILITY TO ACCEPT TWO PAD LOCKS, INTERLOCKED WITH COVER IN CLOSED POSITION, AND WINDOWS TO VIEW VISIBLE BLADE IN OPEN AND CLOSED

POSITION.

NON-FUSIBLE SWITCHES

1. TYPE HD, HEAVY DUTY, SINGLE THROW, 600 V AC, 1200 A AND SMALLER: UL 98 AND NEMA KS 1, HORSEPOWER RATED, LOCKABLE HANDLE WITH CAPABILITY TO ACCEPT THREE PADLOCKS, INTERLOCKED WITH COVER IN CLOSED POSITION, AND WINDOWS TO VIEW VISIBLE BLADE IN OPEN AND CLOSED POSITION.

ACCESSORIES:PROVIDE EQUIPMENT GROUNDING KITS FOR ALL DISCONNECT SWITCHES.

APPLICATION AND INSTALLATION

IF MOUNTING HEIGHTS OR OTHER LOCATION CRITERIA ARE NOT INDICATED, ARRANGE AND INSTALL COMPONENTS AND

EQUIPMENT TO PROVIDE THE MAXIMUM POSSIBLE HEADROOM.

MATERIALS AND COMPONENTS: INSTALL LEVEL, PLUMB, AND PARALLEL AND PERPENDICULAR TO OTHER BUILDING SYSTEMS

AND COMPONENTS, UNLESS OTHERWISE INDICATED.

EQUIPMENT: INSTALL TO FACILITATE SERVICE, MAINTENANCE, AND REPAIR OR REPLACEMENT OF COMPONENTS. CONNECT

FOR EASE OF DISCONNECTING, WITH MINIMUM INTERFERENCE WITH OTHER INSTALLATIONS.

MDP-1

INVERTER

1-122

2-122

3-122

ELEC. ROOM

WOMEN

MEN

JAN.

LOBBY

PANEL 'A'

PANEL 'MDP'

600A MAIN

DISC. SW.

METER

600A

FUSED

DISCONNECT

600A

UTILITY

ACCESSIBLE

DISCONNECT C

O

PY

R

IG

H T

S

PO

TT

S, S

TE

VE

N S

M

C C

O Y

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

R

EL

EA

SE

D F

O R

PR

O

JE

C

T M

AN

AG

ER

D

AT

E:

N

.B

BA

SE

B Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

D

ES

C

R

IP

TI

O

N N

O

D

AT

E M

AD

E

C H

KD

AP

VD

C

H

EC

KE

D

B Y:

102577.0004

10/04/24

R

AD

N O

R T

O W

N

SH

IP

IV

EN

A

VE

N

U E, W

AY

N E, P A

R O

O F

R

EP

LA

C

EM

EN

T

AN

D P

V D

ES

IG

N

BI

D

PM

M

/2

N /A

N /A

/2 1/

IS

SU

ED

F O

R B

ID

M

LE

JM

T

JM

T

/2

3/

R

EI

SS

U

ED

F

O R

B

ID

TM

F

C M

F

JM

T

/2

1/

R

EI

SS

U

ED

F

O R

B

ID

TM

F

C M

F

JM

T N

O T

FO

R

C O

N

ST

R U

C

TI

O N

N or th P ar k

R oa d R ea di ng , P

A

-0

0.

1.

C re ek si de L an e

Li tit z, P

A

7.

8.

E ng in ee rs a nd C on su lta nt s

SP

O

TT

S, S

TE

VE

N S

M

C C

O Y ss m gr ou p.

co m

R E

A D

IN

G

L A

N C

A S

T E

R

R om a C or po ra te

C en te r, S ui te

N

C ed ar C re st

B lv d A lle nt ow n, P A

0.

9.

L E

H

IG

H V

A L

L E

Y

E as t E va ns S tre et

W es t C he st er

, P A

0.

1.

W E

S T

C H

E S

T E

R

CONTRACT 2

SCALE: 18"=1'-0"

0'4' 4' 8' 12' 16' 20'

GARAGE & OFFICE BUILDING

PROPOSED ROOF PLAN

EP.1-01-PW

102577.0004

EP.1-01-PW

EL

EC

TR

IC

AL

PO

W

ER

GA

RA

GE

O

FF

IC

E

BU

IL

DI

NG

A

ND

B

RE

AK

R

OO

M B

UI

LD

IN

G

- P

RO

PO

SE

D

PL

AN

S

C

JC

C

JC

SA

N

SCALE: 14"=1'-0"

4' 8'0' 4'

BREAK ROOM BUILDING

PARTIAL FIRST FLOOR PLAN

GENERAL NOTE:

PROPOSED ROOF PLAN INDICATES BASIS OF DESIGN

LAYOUT FOR THE PV MODULES, ETC INDICATED ON THE

EQUIPMENT SPECIFICATIONS AND SCHEDULES ON

DRAWING E.5-01-PW.

SUBSTITUTIONS AND ANY CHANGE IN PANEL SIZE, RATING,

ETC FOR AN EQUIVALENT ARRAY OUTPUT SHALL INCLUDE

AN UPDATED PROPOSED ROOF PLAN INDICATING THE

REVISED ARRAY FOOTPRINT AND SETBACKS AT ROOF

EDGE, OBSTRUCTIONS, ETC.

4' -0

(M

IN

INVERTER INVERTER

INVERTER

4-122

4-222

5-122

5-222

6-122

6-222

7-122

7-222

8-120

8-220

9-120

10-121

PANEL D1

PANEL D2

NEW MDP-2

C O

PY

R

IG

H

T

S

PO

TT

S, S

TE

VE

N

S

M C

C O

Y

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

R

EL

EA

SE

D F

O R

PR

O

JE

C

T M

AN

AG

ER

D

AT

E:

N

.B

BA

SE

B Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

D

ES

C

R

IP

TI

O

N N

O

D

AT

E M

AD

E

C H

KD

AP

VD

C

H

EC

KE

D

B Y:

102577.0004

10/04/24

R

AD

N O

R T

O W

N

SH

IP

IV

EN

A

VE

N

U E, W

AY

N E, P A

R O

O F

R

EP

LA

C

EM

EN

T

AN

D P

V D

ES

IG

N

BI

D

PM

M

/2

N /A

N /A

/2 1/

IS

SU

ED

F O

R B

ID

M

LE

JM

T

JM

T

/2

3/

R

EI

SS

U

ED

F

O R

B

ID

TM

F

C M

F

JM

T

/2

1/

R

EI

SS

U

ED

F

O R

B

ID

TM

F

C M

F

JM

T N

O T

FO

R

C O

N

ST

R U

C

TI

O N

N or th P ar k

R oa d R ea di ng , P

A

-0

0.

1.

C re ek si de L an e

Li tit z, P

A

7.

8.

E ng in ee rs a nd C on su lta nt s

SP

O

TT

S, S

TE

VE

N S

M

C C

O Y ss m gr ou p.

co m

R E

A D

IN

G

L A

N C

A S

T E

R

R om a C or po ra te

C en te r, S ui te

N

C ed ar C re st

B lv d A lle nt ow n, P A

0.

9.

L E

H

IG

H V

A L

L E

Y

E as t E va ns S tre et

W es t C he st er

, P A

0.

1.

W E

S T

C H

E S

T E

R

CONTRACT 2

SCALE: 18"=1'-0"

0'4' 4' 8' 12' 16' 20'

NORTH SHED - PROPOSED ARRAY PLAN

EP.1-02-PW

102577.0004

EP.1-02-PW

AR

C

H

IT

EC

TU

R

AL

N O

R

TH

S H

ED

PR

O

PO

SE

D P

LA

N

S

C

JC

C

JC

SA

N

SCALE: 14"=1'-0"

4' 8'0' 4'

NORTH SHED

PARTIAL FIRST FLOOR PLAN

GENERAL NOTE:

PROPOSED ROOF PLAN INDICATES BASIS OF DESIGN

LAYOUT FOR THE PV MODULES, ETC INDICATED ON THE

EQUIPMENT SPECIFICATIONS AND SCHEDULES ON

DRAWING E.5-01-PW.

SUBSTITUTIONS AND ANY CHANGE IN PANEL SIZE, RATING,

ETC FOR AN EQUIVALENT ARRAY OUTPUT SHALL INCLUDE

AN UPDATED PROPOSED ROOF PLAN INDICATING THE

REVISED ARRAY FOOTPRINT AND SETBACKS AT ROOF

EDGE, OBSTRUCTIONS, ETC.

600A

600 AMP

FUSIBLE NEMA 1

DISCONNECT

LOCKABLE IN THE OPEN POSITION

UTILITY ACCESSIBLE

DISCONNECT SWITCH

600A

NEMA 3R

LOCKABLE, VISIBLE BLADE

INV.

#2

ARRAY 1

1 STRINGS

OF 11 PV

OPTIMIZERS

W/ 2

MODULES

PER STRING

INV.

#1

60A-3P

MDP-1 INVERTER COMBINER PANEL

600 AMP 208Y/120V-3Ø, 4W, - NEMA 3R

600A-3P

60A-3P 60A-3P

ARRAY 2

1 STRINGS

OF 11 PV

OPTIMIZERS

W/ 2

MODULES

PER STRING

2 #10 1000 VDC PV

WIRE - 1 #8G (TYP.)2

(TYP.)

(TYP.)

60A-3P AC DISC. (TYP.)

DC DISC. UNIT (TYP.)

INVERTER POWER

PACK (TYP.)

1-1/4" PVC SCH 40 - 3 #4, 1 #10

& 1 #10G, CU, THWN-2

(TYPICAL)

(2) 4" C - 4 #600KCMIL,

& 1 #1/0G, CU, THWN-2

INV.

#4

INV.

#3

MDP-2 INVERTER COMBINER PANEL

600 AMP 208Y/120V-3Ø, 4W, - NEMA 3R

INV.

#7

INV.

#6

INV.

#5

INV.

#10

INV.

#9

INV.

#8

600A-3P

60A-3P 60A-3P 60A-3P 60A-3P 60A-3P 60A-3P 60A-3P 60A-3P

ARRAY 3

1 STRINGS

OF 11 PV

OPTIMIZERS

W/ 1-2

MODULES

PER STRING

ARRAY 4

2 STRINGS

OF 11 PV

OPTIMIZERS

W/ 2

MODULES

PER STRING

ARRAY 5

2 STRINGS

OF 11 PV

OPTIMIZERS

W/ 2

MODULES

PER STRING

ARRAY 7

2 STRINGS

OF 11 PV

OPTIMIZERS

W/ 2

MODULES

PER STRING

ARRAY 8

2 STRINGS

OF 10 PV

OPTIMIZERS

W/ 2

MODULES

PER STRING

ARRAY 9

1 STRINGS

OF 10 PV

OPTIMIZERS

W/ 2

MODULES

PER STRING

ARRAY 10

1 STRINGS

OF 11 PV

OPTIMIZERS

W/ 1-2

MODULES

PER STRING

ARRAY 6

2 STRINGS

OF 11 PV

OPTIMIZERS

W/ 2

MODULES

PER STRING

1 2

1 2 1 2 1 2 1 2 1 2 1 2 1 2

1 2 1 2 4

3 3 3 3 3 3 3

3 3

(2) 4" C - 4 #600KCMIL,

& 1 #1/0G, CU, THWN-2

P1101

POWER OPTIMIZER

PV

MODULE

PV

MODULE

NEXT POWER OPTIMIZER AND

PAIR OF PV MODULES IN STRING

PREVIOUS POWER OPTIMIZER AND

PAIR OF PV MODULES IN STRING

1 1

M

PECO METER

SERIAL #016998901

250A-3P250A-3P250A-3P

GENERATOR

PANEL

EXISTING

CIRCUITPANEL B

600A

EXISTING DISTRIBUTION PANEL

800 AMP 208/120V-3Ø, 4W, 65KAIC

GENERAL ELECTRIC TYPE SCP P;US

JOB NO. 72617

EXISTING PAD MOUNTED

TRANSFORMER

EXISTING

UNDERGROUND

CABLE

250A-3P400A-3P

EXISTING

CIRCUITPANEL C

C O

PY

R

IG

H

T

S

PO

TT

S, S

TE

VE

N

S

M C

C O

Y

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

DIGITAL FILENAMEDATE

WORK ORDER NUMBER

DRAWING NUMBER

R

EL

EA

SE

D F

O R

PR

O

JE

C

T M

AN

AG

ER

D

AT

E:

N

.B

BA

SE

B Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

D

ES

C

R

IP

TI

O

N N

O

D

AT

E M

AD

E

C H

KD

AP

VD

C

H

EC

KE

D

B Y:

102577.0004

10/04/24

R

AD

N O

R T

O W

N

SH

IP

IV

EN

A

VE

N

U E, W

AY

N E, P A

R O

O F

R

EP

LA

C

EM

EN

T

AN

D P

V D

ES

IG

N

BI

D

PM

M

/2

N /A

N /A

/2 1/

IS

SU

ED

F O

R B

ID

M

LE

JM

T

JM

T

/2

3/

R

EI

SS

U

ED

F

O R

B

ID

TM

F

C M

F

JM

T

/2

1/

R

EI

SS

U

ED

F

O R

B

ID

TM

F

C M

F

JM

T N

O T

FO

R

C O

N

ST

R U

C

TI

O N

N or th P ar k

R oa d R ea di ng , P

A

-0

0.

1.

C re ek si de L an e

Li tit z, P

A

7.

8.

E ng in ee rs a nd C on su lta nt s

SP

O

TT

S, S

TE

VE

N S

M

C C

O Y ss m gr ou p.

co m

R E

A D

IN

G

L A

N C

A S

T E

R

R om a C or po ra te

C en te r, S ui te

N

C ed ar C re st

B lv d A lle nt ow n, P A

0.

9.

L E

H

IG

H V

A L

L E

Y

E as t E va ns S tre et

W es t C he st er

, P A

0.

1.

W E

S T

C H

E S

T E

R

CONTRACT 2

EP.5-01-PW

102577.0004

EP.5-01-PW

EL

EC

TR

IC

AL

SI

N G

LE

L

IN

E

D

IA

G R

AM

C

JC

C

JC

NO SCALE

SINGLE LINE DIAGRAM

CONNECT NUMBER OF PV STRINGS AS INDICATED TO INVERTER. EACH PV STRING CONSISTS OF 20 OR 22 PV

MODULES CONNECTED IN SERIES.

PROVIDE COPPER #10 AWG PV WIRE, TYPE PV, RATED AT 1000 VOLTS, CIRCUIT TO THE GROUP OF 20 OR 22 PV MODULES CONNECTED IN SERIES FOR THE STRING AND CIRCUIT EACH OF THE NUMBER OF STRINGS INDICATED TO THE INVERTER CONNECTION UNIT. CONNECT THE #8 AWG GROUND WIRE FROM THE INVERTER GROUND TO THE RACKING SYSTEM GROUND CONNECTION POINT FOR EACH PV ARRAY. PROVIDE #8 AWG GROUND WIRE TO

INTERCONNECT SEPARATE RACKING SYSTEMS WITHIN EACH PV ARRAY.

NOTES:

INVERTER TRIP SETTINGS TABLE

PROTECTIVE ELEMENT EVENT TYPICAL SETTINGS THRESHOLD TIME (SEC)

27 UNDER-VOLTAGE

27-1 0.50 pu V (104 VOLTS) 0.16

27-2 0.88 pu V (183 VOLTS) 2.00

59 OVER-VOLTAGE

59-1 1.20 pu V (250 VOLTS) 0.16

59-2 1.10 pu V (228.8 VOLTS) 1.00

81o OVER-FREQUENCY 81O-1 60.5 Hz 0.16

81u UNDER-FREQUENCY 81U-1 57.0 Hz 0.16

LABELS

AC SYSTEM RATING - 690.54

ALL INTERACTIVE SYSTEM(S) POINTS OF

CONNECTION WITH OTHER SOURCES -

INVERTER OUTPUT CONNECTION AT AC

DISCONNECTS AND SERVICE PANEL DOOR

WARNING THIS PANEL HAS SECONDARY

POWER SOURCE FROM PHOTOVOLTAIC

SYSTEM. TURN-OFF PHOTOVOLTAIC

SYSTEM BREAKER PRIOR TO SERVICING

PANEL. MAX AC OUTPUT CURRENT: XXX.X

AMPS OPERATING AC VOLTAGE XXXV

OPEN CIRCUIT VOLTAGE

DC DISCONNECTS - 690.17

WARNING ELECTRIC SHOCK HAZARD. DO

NOT TOUCH TERMINALS. TERMINALS ON

BOTH LINE AND LOAD SIDES MAY BE

ENERGIZED IN THE OPEN POSITION.

EQUIPMENT SCHEDULE

PART NO. NAME QUANTITY DESCRIPTION

1 PV MODULE 323 585 W MODULES 1000VDC

2 P1101 POWER OPTIMIZER 162 SOLAREDGE P1101 POWER OPTIMIZER

3 17 KW INVERTER 10 17 KW INVERTER, SOLAREDGE

4 MDP-1 INVERTER COMBINER PANEL 2 208/120 VAC, 3ɸ, 4W, 600A MCB DISTRIBUTION PANEL, NEMA 3R

5 UTILITY ACCESSIBLE DISCONNECT 1 208/120 VAC, 3ɸ, 4W, 600A, VISIBLE BLADE, LOCKABLE, VIEWING

WINDOW,

6 FUSED DISCONNECT 1 208/120 VAC, 3ɸ, 4W, 600A FUSED DISCONNECT SWITCH, VISIBLE

BLADE, LOCKABLE, VIEWING WINDOW,

PV SYSTEM SUMMARY

SYSTEM ROOF MOUNTED

PV MODULE MODEL (QUANTITY) HANWHA Q CELLS, Q.PEAK DUO

XL-G11S 585 (325)

PV MODULE STC DC RATING 585 W

PV MODULES PER SOURCE CIRCUIT

(STRING) 20-22

TOTAL PV MODULE COUNT 323

TOTAL STC DC SYSTEM SIZE 188.96 KW

TOTAL AC SYSTEM SIZE 173 KW

DC/AC RATIO 1.09

INVERTER MODEL (QUANTITY) SOLAREDGE SE17.3KUS (10)

PECO CONTACT INFORMATION:

ACCOUNT #:

METER #: 017112749

EQUIPMENT SPECIFICATIONS

PHOTOVOLTAIC SOLAR MODULE

(PANEL) - HANWHA Q CELLS, Q.PEAK

DUO XL-G11S 585 (585W)

585 W

MAXIMUM POWER P_max 585 W

MAXIMUM POWER CURRENT I_mp 12.97 A

SHORT CIRCUIT CURRENT I_sc 13.57 A

OPEN CIRCUIT VOLTAGE V_oc 53.59 V

INVERTER -

SOLAREDGE SE17.3KUS 17.3 KW

MAXIMUM POWER OUTPUT 17,300 W

PEAK POWER TRACKING (MPPT) 370-600V

DC MAXIMUM VOLTAGE 600V

OUTPUT VOLTAGE RANGE 105-229V

OUTPUT VOLTAGE 208/120 VAC

AC MAXIMUM AMPERAGE 48.25A

CEC EFFICIENCY 97.5%

GENERAL NOTE:

ELECTRICAL CONTRACTOR SHALL BE

RESPONSIBLE FOR SUBMISSION OF UTILITY

INTERCONNECTION APPLICATION.

GENERAL NOTE:

PROPOSED SINGLE LINE, EQUIPMENT SPECIFICATIONS AND

EQUIPMENT SCHEDULES INDICATE THE BASIS OF DESIGN FOR

THE PV ARRAY.

SUBSTITUTIONS SHALL BE PROVIDED AS FOR REVIEW BY THE

ENGINEER OF RECORD ACCORDING TO SPECIFICATION

SECTION

012500 - "SUBSTITUTION PROCEDURES." ANY SUBSTITUTIONS

SHALL RESULT IN AN EQUIVALENT ARRAY OUTPUT.

Sheets and Views
G.0-00-PW-contract 2
G.1-01-PW
E.0-01-PW
EP.1-01-PW
EP.1-02-PW
E.5-01-PW

File details come from the government source that posted it. Updated .