4. FIRST FLOOR POWER.pdf
PDF 345 KB Posted
- Solicitation number
- 36C26125R0068
About this file
This is a power distribution first floor plan drawing for Building 22 at the VA Central California Health Care System located in Fresno, CA. The detailed electrical schematic includes multiple power system components such as motors (marked with "M"), panel boards, transformers, emergency generators, battery systems, and various electrical routing connections. The drawing uses standard electrical symbols to map out power distribution routes, including connections to multiple motor control centers (MCC-1, MCC-2, MCC-3, MCC-4), chillers, boilers, and other critical infrastructure equipment. The plan is drawn at a scale of 3/16" = 1'-0", was created by V Logic Systems Inc. on 04-05-2010, and is part of the Office of Facilities Management documentation for the Power House and Cooling Tower project.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot 6"
6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot
6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
97 8654321
Revisions Date
Professional Seal
Approved Project Director:
Drawing Title
Location:
Project Title
Checked:
Building Number:
Drawing Number:
Project Number:
Date:
BUILDING 22 FIRST FLOOR PLAN
POWER
Architects/Engineers/Consultants:
04-05-2010
Office of
Facilities
Management
Dwg. of
Scale :
"=1'-0"
Final Submission
04-05-2010
Drawn:
VL
File Name:
FR-22-01PW
V Logic Systems Inc.
2352 Main Street, Suite 207 Concord, MA 01742 Phone: 978-341-9000 www.vlogicsystems.com
POWER HOUSE AND COOLING TOWER
2615 E. Clinton
Avenue
Fresno, CA 93703
M
COP-1
COP-2
COP-3
SP-1
SP-2
H
2UH1
M
M
AC-2
AC-1
PTRV-1
TO MCC-1
M
OB-1
M
OB-2
M M
CWP-1 CWP-2
BR
EDR
M
BR-22
ER-14,16
CHP-1
CHP-2
M 2-P32-P2
ER-17
MM
2-P1
M M
2-P6
2-P7
2-P4
2-P5
M M
M
M
TO 750 KVA
TRANSFORMER
SWB10
BSB
M 2-P10
ER-20/2
ER-24
BATTERYS
ER-19
EMERGENCY
GENERATOR
130/208V OR
277/480V⌀4W
M
M
ER-21
M M
CH-1
M
TO MCC-1
BR-23
M
OB-3
M
2CF-1
TO PUMP HOUSE
M
SPR-1
TO PUMP HOUSE
PANEL FOR
TRIPLE WIDE
TRAILER
MM
M M M
LVDP
M
PTRV-2
TO MCC-1
M
SPR-2
M
CAB RAN
2-HVU-1
AH
BR-22,24
BR-30/2
M
ER-23
2PTRV-47
EXISTING 300KV
TRANSFORMER
12 KV TO
120/203V, 3⌀
ER-13,15
ER-17
CAB RAN
2-HVU-2
2-PTRV-5
ON ROOF
PULL CONNECTOR
CU
PULL BOX
ER-20
CD
TO LVDP
MCC-3
OPD
MCC-4 BUILDING-31
MCC BUILDING-24
MM
PANEL BR
TO LVPD
S
TO
TRA
BSB
PANEL ER
PANEL PR
M M M
CH-2
BOILER INSTRUMENTATION PANEL
MCC-2
MCC1
MCCB
ER-18
GENERATOR
CONTROL PANEL
2PB-8
J
WATER
SOFTNER
ER-24
CONTINUATION
DUPLEX IN THE CEILING
DISCONNECT SWITCH / FUSED OR UNFUSED SAFETY SWITCH
HOME RUN
CONDUIT DOWN
MOTOR
SYMBOLS
DESCRIPTION
LEGEND
M
120/208V., 3⌀, 4 W PANEL BOARD
HOT WIRE
DUPLEX RECEPTACLE
JUNCTION BOX (CEILING MOUNTED)
J
ELECTRIC THERMOSTAT
SINGLE POLE SWITCH
AUTOMATIC TRANSFER SWITCH
S
TO MCC-1 TO MCC-1
TO MCC-1
TO MCC-1
3" BATTERY
CABLES
CHILLER RM
CONFERENCE
PATIENT
TOILET
PATIENT
TOILET
ENGG
OFFICE
BOILER RM
STAFF
TOILET
EQUIP
STORAGEBOILER
File details come from the government source that posted it. Updated .