36E77618R0051 ATTACHMENT 4 - Basis of Design-No Substitution List-Post-Final Submittal.pdf

View the file

Other files

File Type Posted
36E77618C0024-000.docx DOCX document
36E77618R0051-0005001.docx DOCX document
36E77618R0051-0005000.docx DOCX document
36E77618R0051-0004001.pdf PDF
36E77618R0051-0004000.docx DOCX document
36E77618R0051-00003002.docx DOCX document
36E77618R0051-00003003.pdf PDF
36E77618R0051-00002000.docx DOCX document
36E77618R0051-00001005.pdf PDF
36E77618R0051-00001007.pdf PDF
36E77618R0051-00001008.pdf PDF
36E77618R0051-00001004.pdf PDF
36E77618R0051-00001003.pdf PDF
36E77618R0051-00001009.docx DOCX document
36E77618R0051-00001000.docx DOCX document
36E77618R0051-00001006.pdf PDF
36E77618R0051-00001002.pdf PDF
36E77618R0051-00001001.pdf PDF
36E77618R0051-012.docx DOCX document
36E77618R0051-001.docx DOCX document
36E77618R0051-002.pdf PDF
36E77618R0051-005.pdf PDF
36E77618R0051-009.pdf PDF
36E77618R0051-007.pdf PDF
36E77618R0051-004.pdf PDF
36E77618R0051-008.pdf PDF
36E77618R0051-006.pdf PDF
36E77618R0051-003.pdf PDF
36E77618R0051-011.docx DOCX document
36E77618R0051-000.docx DOCX document
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Basis-Of-Design/No Substitutions List Replace Defective Steam Traps and Correct Condensate Overpressurization

Specification

Section

Title Paragraph Item Mfgr./ Brand Name or Equal Basis-Of-Design - Product Info

(Model #/Name, Color, etc.)

Substituti ons

Accepted?

Division 1 SPECIAL SECTIONS

01 00 00 General Requirements - N/A NA NA NA

01 32 16.15 Project Schedules - N/A NA NA NA

01 33 23 Shop Drawings, Product Data, and

Samples

- N/A NA NA NA

01 35 26 Safety Requirements - N/A NA NA NA

01 42 19 Reference Standards - N/A NA NA NA

01 45 29 Laboratory Testing Services - N/A NA NA NA

01 57 19 Temp Env Controls - N/A NA NA NA

01 58 16 Temp Interior Signage - N/A NA NA NA

01 74 19 Const Waste Mgmt - N/A NA NA NA

01 81 13 Sustainable Design Req'ts. - N/A NA NA NA

Division 2 EXISTING CONDITIONS 02 41 00 Demolition - N/A NA NA NA

02 82 11 Traditional Asbestos Abatement - N/A NA NA NA

02 82 13 Glovebag Asbestos Abatement - N/A NA NA NA

Division 3 CONCRETE

03 30 54 Cast-In-Place Concrete - N/A NA NA NA

Division 4 MASONRY

04 05 15 Mantenance of Masonry 2.2.A Mortar See 09 06 00 Schedule for

Finishes

Match Existing No

04 20 00 Unit Masonry 2.2.A Face Brick See 09 06 00 Schedule for

Finishes

Match Existing No

Division 5 METALS

05 50 00 Metal Fabrications

Division 6 WOOD, PLASTICS & COMPOSITES NOT USED

Division 7 THERMAL & MOISTURE

PROTECTION

07 21 13 Thermal Insulation - N/A NA NA NA

07 72 00 Roof Accessories 090600.2.7.Q Roof Hatch Bilco D-50T, Factory Finish-Mill Aluminum NA

07 84 00 Firestopping - N/A NA NA NA

07 92 00 Joint Sealants - N/A NA NA NA

2.5.B Interior Wall Joint Cover Assemblies See 09 06 00 Schedule for

Finishes

Match Existing Yes

2.5.C Extruded Thermoplastic Rubber Joint Ass'ys See 09 06 00 Schedule for

Finishes

Match Existing Yes

2.5.D Ceiling & Soffit Joint Assemblies See 09 06 00 Schedule for

Finishes

Match Existing Yes

07 95 00 Expansion Joint Assemblies

VA Iowa City Medical Center

636A8-14-006 1 of 4 Post-Final Submittal - 1/22/2018

Basis-Of-Design/No Substitutions List Replace Defective Steam Traps and Correct Condensate Overpressurization

Section

Title Paragraph Item Mfgr./ Brand Name or Equal Basis-Of-Design - Product Info

(Model #/Name, Color, etc.)

Substituti ons

Accepted?

Division 8 OPENINGS

08 31 13 Access Doors & Frames 2.2.A Access Doors & Frames See 09 06 00 Schedule for

Finishes

Match Existing Yes

Division 9 FINISHES

09 06 00 Schedule of Finishes - See individual Specification Sections for submittal items

09 22 16 Non-Structural Metal Framing - N/A NA NA NA

09 29 00 Gypsum Board 2.3.C.1 Reveal Channel Fry-Reglet DRM-50-50 Yes

2.1.F.4.a Interior & Exterior Corners Schluter, Inc. Rondec Yes

2.1.F.4.b Wainscot Top Ceramiche Cesar Verse Sugar Yes

2.2.A.4 Backer Units National Gypsum Co. PermaBase - 5/8"T Yes

2.5.C.2 Prepkgd. Dry Mortar Mix Bostik, Inc. Big Tile & Stone Latex Modified Yes

2.5.H Waterproofing Membrane Schluter, Inc. Kerdi Yes

2.7 Grouting Mat'ls. - Premixed Urethane Grout Bostik, Inc. Tru Color - Rapid Cure Yes

2.10.A Metal Divider Strips Schluter, Inc. Deco - Anodized Aluminum Yes

2.1.4 Exposed Grid Suspension System AT-1, AT (SP) Armstrong Ceiling Solutions Prelude XL 15/16" Exposed Tee - White No

2.8.A.7.a Acoustical Ceiling Tile AT-1 Armstrong Ceiling Solutions Cirrus 584 24"x24"x1" Edge Profile 15/16"

Beveled Tegular Tile

No

2.8.B.1 Clean Room Ceiling Tile AT (SP) Armstrong Ceiling Solutions Clean Room Mylar FV 1720 24"x24"x1" Tiles No

2.2.A.3.a Resilient Base Johnsonite Tightlock-80 Fawn CB, 6" High Yes

2.2.3.b Resilient Base Johnsonite Millwork / Inflection MW-XX-G-80 Fawn, 6"

High

Yes

096000.2.9.X Paint Sherwin Williams See Sec 09 06 00.2.9.X for listing of paint color numbrs/names

No

096000.2.9.X Stains Sherwin Williams Match existing No

Division 10 SPECIALTIES NOT USED

Division 11 EQUIPMENT NOT USED

Division 12 FURNISHINGS NOT USED

Division 13 SPECIAL CONSTRUCTION NOT USED

Division 14 CONVEYING EQUIPMENT NOT USED

09 30 13 Ceramic Tiling

09 51 00 Acoustical Ceilings

09 91 00 Painting

09 56 13 Resilient Base & Accessories

636A8-14-006 2 of 4 Post-Final Submittal - 1/22/2018

Basis-Of-Design/No Substitutions List Replace Defective Steam Traps and Correct Condensate Overpressurization

Section

Title Paragraph Item Mfgr./ Brand Name or Equal Basis-Of-Design - Product Info

(Model #/Name, Color, etc.)

Substituti ons

Accepted?

Division 21 FIRE SUPPRESSION NOT USED

Division 22 PLUMBING NOT USED

Division 23 HVAC

23 05 11 Common Work Results for HVAC - N/A NA NA NA

23 05 12 General Motor Req'ts - HVAC &

Steam Generation

- N/A NA NA NA

23 05 41 Noise/Vibration Control - HVAC

Piping/Eqpt.

- N/A NA NA NA

23 05 93 Testing, Adjusting, & Balancing for

HVAC

- N/A NA NA NA

23 07 11 HVAC & Boiler Plant Insulation - N/A NA NA NA

23 09 23 Direct-Digital Control System for

HVAC

- N/A NA NA NA

23 21 13 Hydronic Piping - N/A NA NA NA

2.6.E Globe & Angle Valves Adams MAK Yes

2.9.E.7 Expansion Joint Loop MetraFlex Type ML Yes

Schedule (Dwg) Steam Pressure Reducing Valve Watson McDaniel HD Yes

Schedule (Dwg) Safety Relief Valve Watson McDaniel SV1 Yes

Schedule (Dwg) Steam Traps Watson McDaniel WFT, 1031 Yes

23 22 23 Steam Condensate Pumps Schedule (Dwg) Condensate Pumps Watson McDaniel PMP Yes

23 25 00 HVAC Water Treatment - N/A NA NA NA

23 31 00 HVAC Ducts & Casings - N/A NA NA NA

23 34 00 HVAC Fans Schedule (Dwg) Fans Trane SE1-16 Yes

23 37 00 Air Outlets & Inlets - N/A NA NA NA

23 82 00 Convection Heating & Cooling Units Schedule (Dwg) Unit Heaters Trane S Yes

23 82 16 Air Coils Schedule (Dwg) Air Coils Trane ST Yes

Division 25 INTEGRATED AUTOMATION NOT USED

23 22 13 Steam & Condensate Heating Piping

636A8-14-006 3 of 4 Post-Final Submittal - 1/22/2018

Basis-Of-Design/No Substitutions List Replace Defective Steam Traps and Correct Condensate Overpressurization

Section

Title Paragraph Item Mfgr./ Brand Name or Equal Basis-Of-Design - Product Info

(Model #/Name, Color, etc.)

Substituti ons

Accepted?

Division 26 ELECTRICAL

26 05 11 Req'ts for Electrical Installations - N/A NA NA NA

26 05 19 Low-Voltage Electrical Power

Conductors & Cables

- N/A NA NA NA

26 05 26 Grounding & Bonding for Electrical

Systems

- N/A NA NA NA

26 05 27 Supporting Devices - N/A NA NA NA

26 05 33 Raceway & Boxes for Electrical

Systems

- N/A NA NA NA

26 28 16 Disconnect Switches - N/A NA NA NA

26 51 00 Interior Lighting - N/A NA NA NA

Division 27 COMMUNICATIONS NOT USED

Division 28 ELECTRONIC SAFETY & SECURITY NOT USED

Division 31 EARTHWORK NOT USED

Division 32 EXTERIOR IMPROVEMENTS NOT USED

Division 33 UTILITIES NOT USED

Division 34 TRANSPORTATION NOT USED

Division 48 ELECTRICAL POWER GENERATION NOT USED

636A8-14-006 4 of 4 Post-Final Submittal - 1/22/2018