Text version
Basis-Of-Design/No Substitutions List Replace Defective Steam Traps and Correct Condensate Overpressurization
Specification
Section
Title Paragraph Item Mfgr./ Brand Name or Equal Basis-Of-Design - Product Info
(Model #/Name, Color, etc.)
Substituti ons
Accepted?
Division 1 SPECIAL SECTIONS
01 00 00 General Requirements - N/A NA NA NA
01 32 16.15 Project Schedules - N/A NA NA NA
01 33 23 Shop Drawings, Product Data, and
Samples
- N/A NA NA NA
01 35 26 Safety Requirements - N/A NA NA NA
01 42 19 Reference Standards - N/A NA NA NA
01 45 29 Laboratory Testing Services - N/A NA NA NA
01 57 19 Temp Env Controls - N/A NA NA NA
01 58 16 Temp Interior Signage - N/A NA NA NA
01 74 19 Const Waste Mgmt - N/A NA NA NA
01 81 13 Sustainable Design Req'ts. - N/A NA NA NA
Division 2 EXISTING CONDITIONS 02 41 00 Demolition - N/A NA NA NA
02 82 11 Traditional Asbestos Abatement - N/A NA NA NA
02 82 13 Glovebag Asbestos Abatement - N/A NA NA NA
Division 3 CONCRETE
03 30 54 Cast-In-Place Concrete - N/A NA NA NA
Division 4 MASONRY
04 05 15 Mantenance of Masonry 2.2.A Mortar See 09 06 00 Schedule for
Finishes
Match Existing No
04 20 00 Unit Masonry 2.2.A Face Brick See 09 06 00 Schedule for
Finishes
Match Existing No
Division 5 METALS
05 50 00 Metal Fabrications
Division 6 WOOD, PLASTICS & COMPOSITES NOT USED
Division 7 THERMAL & MOISTURE
PROTECTION
07 21 13 Thermal Insulation - N/A NA NA NA
07 72 00 Roof Accessories 090600.2.7.Q Roof Hatch Bilco D-50T, Factory Finish-Mill Aluminum NA
07 84 00 Firestopping - N/A NA NA NA
07 92 00 Joint Sealants - N/A NA NA NA
2.5.B Interior Wall Joint Cover Assemblies See 09 06 00 Schedule for
Finishes
Match Existing Yes
2.5.C Extruded Thermoplastic Rubber Joint Ass'ys See 09 06 00 Schedule for
Finishes
Match Existing Yes
2.5.D Ceiling & Soffit Joint Assemblies See 09 06 00 Schedule for
Finishes
Match Existing Yes
07 95 00 Expansion Joint Assemblies
VA Iowa City Medical Center
636A8-14-006 1 of 4 Post-Final Submittal - 1/22/2018
Basis-Of-Design/No Substitutions List Replace Defective Steam Traps and Correct Condensate Overpressurization
Section
Title Paragraph Item Mfgr./ Brand Name or Equal Basis-Of-Design - Product Info
(Model #/Name, Color, etc.)
Substituti ons
Accepted?
Division 8 OPENINGS
08 31 13 Access Doors & Frames 2.2.A Access Doors & Frames See 09 06 00 Schedule for
Finishes
Match Existing Yes
Division 9 FINISHES
09 06 00 Schedule of Finishes - See individual Specification Sections for submittal items
09 22 16 Non-Structural Metal Framing - N/A NA NA NA
09 29 00 Gypsum Board 2.3.C.1 Reveal Channel Fry-Reglet DRM-50-50 Yes
2.1.F.4.a Interior & Exterior Corners Schluter, Inc. Rondec Yes
2.1.F.4.b Wainscot Top Ceramiche Cesar Verse Sugar Yes
2.2.A.4 Backer Units National Gypsum Co. PermaBase - 5/8"T Yes
2.5.C.2 Prepkgd. Dry Mortar Mix Bostik, Inc. Big Tile & Stone Latex Modified Yes
2.5.H Waterproofing Membrane Schluter, Inc. Kerdi Yes
2.7 Grouting Mat'ls. - Premixed Urethane Grout Bostik, Inc. Tru Color - Rapid Cure Yes
2.10.A Metal Divider Strips Schluter, Inc. Deco - Anodized Aluminum Yes
2.1.4 Exposed Grid Suspension System AT-1, AT (SP) Armstrong Ceiling Solutions Prelude XL 15/16" Exposed Tee - White No
2.8.A.7.a Acoustical Ceiling Tile AT-1 Armstrong Ceiling Solutions Cirrus 584 24"x24"x1" Edge Profile 15/16"
Beveled Tegular Tile
No
2.8.B.1 Clean Room Ceiling Tile AT (SP) Armstrong Ceiling Solutions Clean Room Mylar FV 1720 24"x24"x1" Tiles No
2.2.A.3.a Resilient Base Johnsonite Tightlock-80 Fawn CB, 6" High Yes
2.2.3.b Resilient Base Johnsonite Millwork / Inflection MW-XX-G-80 Fawn, 6"
High
Yes
096000.2.9.X Paint Sherwin Williams See Sec 09 06 00.2.9.X for listing of paint color numbrs/names
No
096000.2.9.X Stains Sherwin Williams Match existing No
Division 10 SPECIALTIES NOT USED
Division 11 EQUIPMENT NOT USED
Division 12 FURNISHINGS NOT USED
Division 13 SPECIAL CONSTRUCTION NOT USED
Division 14 CONVEYING EQUIPMENT NOT USED
09 30 13 Ceramic Tiling
09 51 00 Acoustical Ceilings
09 91 00 Painting
09 56 13 Resilient Base & Accessories
636A8-14-006 2 of 4 Post-Final Submittal - 1/22/2018
Basis-Of-Design/No Substitutions List Replace Defective Steam Traps and Correct Condensate Overpressurization
Section
Title Paragraph Item Mfgr./ Brand Name or Equal Basis-Of-Design - Product Info
(Model #/Name, Color, etc.)
Substituti ons
Accepted?
Division 21 FIRE SUPPRESSION NOT USED
Division 22 PLUMBING NOT USED
Division 23 HVAC
23 05 11 Common Work Results for HVAC - N/A NA NA NA
23 05 12 General Motor Req'ts - HVAC &
Steam Generation
- N/A NA NA NA
23 05 41 Noise/Vibration Control - HVAC
Piping/Eqpt.
- N/A NA NA NA
23 05 93 Testing, Adjusting, & Balancing for
HVAC
- N/A NA NA NA
23 07 11 HVAC & Boiler Plant Insulation - N/A NA NA NA
23 09 23 Direct-Digital Control System for
HVAC
- N/A NA NA NA
23 21 13 Hydronic Piping - N/A NA NA NA
2.6.E Globe & Angle Valves Adams MAK Yes
2.9.E.7 Expansion Joint Loop MetraFlex Type ML Yes
Schedule (Dwg) Steam Pressure Reducing Valve Watson McDaniel HD Yes
Schedule (Dwg) Safety Relief Valve Watson McDaniel SV1 Yes
Schedule (Dwg) Steam Traps Watson McDaniel WFT, 1031 Yes
23 22 23 Steam Condensate Pumps Schedule (Dwg) Condensate Pumps Watson McDaniel PMP Yes
23 25 00 HVAC Water Treatment - N/A NA NA NA
23 31 00 HVAC Ducts & Casings - N/A NA NA NA
23 34 00 HVAC Fans Schedule (Dwg) Fans Trane SE1-16 Yes
23 37 00 Air Outlets & Inlets - N/A NA NA NA
23 82 00 Convection Heating & Cooling Units Schedule (Dwg) Unit Heaters Trane S Yes
23 82 16 Air Coils Schedule (Dwg) Air Coils Trane ST Yes
Division 25 INTEGRATED AUTOMATION NOT USED
23 22 13 Steam & Condensate Heating Piping
636A8-14-006 3 of 4 Post-Final Submittal - 1/22/2018
Basis-Of-Design/No Substitutions List Replace Defective Steam Traps and Correct Condensate Overpressurization
Section
Title Paragraph Item Mfgr./ Brand Name or Equal Basis-Of-Design - Product Info
(Model #/Name, Color, etc.)
Substituti ons
Accepted?
Division 26 ELECTRICAL
26 05 11 Req'ts for Electrical Installations - N/A NA NA NA
26 05 19 Low-Voltage Electrical Power
Conductors & Cables
- N/A NA NA NA
26 05 26 Grounding & Bonding for Electrical
Systems
- N/A NA NA NA
26 05 27 Supporting Devices - N/A NA NA NA
26 05 33 Raceway & Boxes for Electrical
Systems
- N/A NA NA NA
26 28 16 Disconnect Switches - N/A NA NA NA
26 51 00 Interior Lighting - N/A NA NA NA
Division 27 COMMUNICATIONS NOT USED
Division 28 ELECTRONIC SAFETY & SECURITY NOT USED
Division 31 EARTHWORK NOT USED
Division 32 EXTERIOR IMPROVEMENTS NOT USED
Division 33 UTILITIES NOT USED
Division 34 TRANSPORTATION NOT USED
Division 48 ELECTRICAL POWER GENERATION NOT USED
636A8-14-006 4 of 4 Post-Final Submittal - 1/22/2018