1. THE ELECTRICAL DRAWINGS INDICATE EXISTING ELECTRICAL ITEMS TO BE REMOVED. THE
DRAWINGS ARE INTENDED TO INDICATE THE SCOPE OF WORK REQUIRED AND DO NOT
INDICATE EVERY BOX, CONDUIT, OR WIRE THAT MUST BE REMOVED. THE CONTRACTOR
SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID AND VERIFY EXISTING CONDITIONS.
2. ELECTRICAL ITEMS (i.e., LIGHTING FIXTURES, RECEPTACLES, SWITCHES, ETC.) REMOVED AND
NOT RELOCATED REMAIN THE PROPERTY OF THE OWNER. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE DISPOSAL OF MATERIAL THE OWNER DOES NOT WANT TO REUSE OR
RETAIN (i.e., FOR MAINTENANCE PURPOSES).
3. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE OWNER BEFORE TURNING OFF
POWER TO CIRCUITS, FEEDERS, PANELS, ETC. COORDINATE ALL OUTAGES WITH OWNER.
CONDUIT CONCEALED IN WALL CONSTRUCTION MAY BE ABANDONED IN PLACE IF NOT
AFFECTED BY OTHER CONSTRUCTION.
4. WHERE LIGHTS, SWITCHES, RECEPTACLES, ETC., ARE BEING REMOVED ALL ASSOCIATED
CONDUIT AND WIRE BACK TO THE PANELBOARD OR FEEDER JUNCTION BOX SERVING THE
DEVICE SHALL ALSO BE REMOVED, UNLESS THE CONDUIT CAN BE REUSED FOR NEW
CONDUCTORS. UNLESS NOTED OTHERWISE.
5. ALL CONDUIT SHALL BE REMOVED WHERE WALLS ARE BEING REMOVED. WHERE CONDUIT IS
IN THE CONCRETE SLAB, CUT OFF FLUSH, PULL OUT WIRE, AND PLUG. WHERE CONDUIT IS
RUN EXPOSED, ALL ASSOCIATED CLAMPS, SUPPORTS, HANGERS, ETC., SHALL ALSO BE
REMOVED.
6. THIS CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER CONTRACTORS AT THE
JOB SITE BEFORE REMOVING EXISTING ELECTRICAL AND INSTALLING NEW ITEMS.
7. EXISTING CONDUIT IN GOOD CONDITION, MAY BE REUSED IN PLACE. RELOCATED EXISTING
CONDUIT SHALL NOT BE ALLOWED. BONDING CONDUCTORS SHALL BE INSTALLED IN ALL
REUSED CONDUIT TO ASSURE PROPER GROUND PATH.
8. EQUIPMENT REMOVAL IN CERTAIN LOCATIONS MAY REQUIRE THE INSTALLATION OF A
JUNCTION BOX TO RECONNECT CIRCUITS THAT REMAIN IN OPERATION. EXTEND CONDUIT
AND WIRING AS REQUIRED TO MAINTAIN POWER TO REMAINING EQUIPMENT.
9. CONTRACTOR SHALL REMOVE AND INSTALL ALL CEILING TILES AS REQUIRED FOR THE
EXECUTION OF ELECTRICAL WORK THAT IS OUTSIDE THE CONTRACT LIMITS OF
CONSTRUCTION. CONTRACTOR SHALL REPLACE CEILING TILES WITH IDENTICAL MATERIAL
WHERE DAMAGED BY THIS CONTRACTOR.
10. BALLASTS MANUFACTURED PRIOR TO 1980 CONTAIN PCBs AND SHALL BE DISPOSED OF BY A
FEDERAL OR STATE E.P.A. APPROVED METHOD AND IN ACCORDANCE WITH SPECIFICATIONS.
11. FLUORESCENT LAMPS CONTAIN MERCURY AND SHALL BE DISPOSED OF BY A FEDERAL OR
STATE E.P.A. APPROVED METHOD AND IN ACCORDANCE WITH SPECIFICATIONS.
GENERAL ELECTRICAL NOTES:
1. "1/E-11" INDICATES DETAIL NUMBER/SHEET NUMBER.
2. "MS-1" INDICATES ELECTRICAL EQUIPMENT DEFINED IN ELECTRICAL SCHEDULES. REFER TO
DRAWINGS CONTAINING ELECTRICAL SCHEDULES FOR REQUIREMENTS. PERMANENT
NAMEPLATE SHALL MATCH FINAL EQUIPMENT NOMEMCLATURE, NOT THE ELECTRICAL
EQUIPMENT TAG NAME. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION
AND IDENTIFICATION REQUIREMENTS.
3. " # " INDICATES KEYED NOTE USED TO DESCRIBE ADDITIONAL INFORMATION OF WORK
REQUIRED, SPECIFIC TO THE SHEET AND/OR DETAIL IT IS SHOWN WITH.
5. ALL ELECTRICAL CONDUCTORS SHALL BE COPPER.
6. ABBREVIATION KEY:
E.C. ELECTRICAL CONTRACTOR
M.C. MECHANICAL CONTRACTOR
G.C. GENERAL CONTRACTOR
AFF ABOVE FINISH FLOOR
C CONDUIT
TYP TYPICAL
+##" MOUNTING HEIGHT FROM FINISHED FLOOR TO CENTERLINE
7. REFER TO MATERIAL LIST AND SPECIFICATIONS FOR FULL DESCRIPTIONS AND
MANUFACTURERS OF ALL DEVICES.
8. LINE TYPE KEY:
NEW WORK BY THIS CONTRACTOR (DARK SOLID LINE)
NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR (DARK
LONG DASHED LINE)
NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN (LIGHT SOLID LINE)
EXISTING TO BE REMOVED BY THIS CONTRACTOR (DARK SHORT DASHED
LINE)
ELECTRICAL INSTALLATION NOTES:
1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADAAG (AMERICANS WITH
DISABILITIES ACT ACCESSIBILITY GUIDELINES).
2. NOT USED
3. A #12 GREEN INSULATED GROUND CONDUCTOR SHALL BE INSTALLED WITH CIRCUIT
CONDUCTORS TO ALL RECEPTACLES.
4. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS AND ABOVE CEILING,ETC. UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. CONDUIT IN MECHANICAL ROOMS, AND
STORAGE ROOMS WITHOUT CEILINGS MAY BE EXPOSED ON BUILDING STRUCTURE. INCREASE
CONDUCTOR SIZE IF POWER CONDUCTOR INCREASES DO TO VOLTAGE DROP.
5. CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS WITH EXISTING CONDITIONS. PRIOR TO
MAKING THE ACTUAL ELECTRICAL INSTALLATION THIS CONTRACTOR SHALL ADJUST
RECEPTACLES, OUTLETS OR CONNECTION LOCATIONS TO ACCOMMODATE FURNITURE AND/OR
EQUIPMENT.
6. ELECTRICAL EQUIPMENT SHALL BE MOUNTED TO AVOID IMPEDANCE OF, OPERATION OF, AND/OR
ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF ELECTRICAL AND
TELECOMMUNICATIONS EQUIPMENT, ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR,
SHALL BE APPROVED IN ADVANCE BY THE OTHER CONTRACTOR.
7. ALL FINAL ELECTRICAL CONNECTIONS TO MOTORS SHALL BE MADE WITH FLEXIBLE METAL
CONDUIT. USE LIQUIDTIGHT CONDUIT AND FITTINGS WHERE SUBJECT TO MOISTURE. ROUTE
GROUND WIRE FROM CIRCUIT GROUND TO MOTOR GROUND THROUGH FLEXIBLE CONDUIT.
FLEXIBLE CONDUIT SHALL NOT EXCEED 6' IN LENGTH.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL OPENINGS
SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE EXPENSE OF
THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR SEALED INTO
OPENINGS.
9. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL BE
TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF
THROUGH-PENETRATION FIRESTOPS.
10. CONTRACTOR SHALL REMOVE AND REINSTALL ALL CEILING TILES AS REQUIRED FOR THE
EXECUTION OF ELECTRICAL WORK THAT IS OUTSIDE THE CONTRACT LIMITS OF CONSTRUCTION.
CONTRACTOR SHALL REPLACE CEILING TILES WITH IDENTICAL MATERIAL WHERE DAMAGED BY
THIS CONTRACTOR.
GENERAL ELECTRICAL EQUIPMENT SCHEDULE
ELECTRICAL LIGHTING SYMBOL LIST
ELECTRICAL POWER SYMBOL LIST
ELECTRICAL SYSTEMS SYMBOL LIST
EX. EXISTING
ELECTRICAL DEMOLITION NOTES:
The FUTURE.
Built SMARTER.®
SUB-BASEMENT FLOOR PLAN - ELECTRICAL DEMOLITION
R T HN O
BE FLOOR PLAN - ELECTRICAL DEMOLITION
BS FLOOR PLAN - ELECTRICAL DEMOLITION
BW FLOOR PLAN - ELECTRICAL DEMOLITION
1E FLOOR PLAN - ELECTRICAL DEMOLITION
3S FLOOR PLAN - ELECTRICAL DEMOLITION
5S FLOOR PLAN - ELECTRICAL DEMOLITION
GENERAL NOTES
KEYNOTES
8W FLOOR PLAN - ELECTRICAL DEMOLITION
R T HN O
11W PENTHOUSE - ELECTRICAL DEMOLITION
8W FLOOR PLAN - LIGHTING
R T HN O
SUB-BASEMENT FLOOR PLAN - POWER & SYSTEMS
BS FLOOR PLAN - POWER & SYSTEMS
1E FLOOR PLAN - POWER & SYSTEMS
5S FLOOR PLAN - POWER & SYSTEMS
8W FLOOR PLAN - POWER & SYSTEMS
R T HN O
11W PENTHOUSE PLAN - POWER & SYSTEMS
R T HN O
PUMP CONNECTION DETAIL
NO SCALE1
DISCONNECT AND STARTER SCHEDULE
REMARKS:
STARTER TYPE: SA - STANDARD ACCESSORIES (INCLUDES * ITEMS)
FV - FULL VOLTAGE *CT - CONTROL TRANSFORMER,
FUSED 120V
PF - PHASE FAILURE RELAY
(5 HP OR GREATER) YD - WYE - DELTA
RE - REVERSING *EO - ELECTRONIC OVERLOAD TO - MELTING THERMAL OVERLOADS
TW - 2 SPEED, 2 WINDING *HA - HAND-OFF-AUTO IN DOOR TS - 2 SPEED SELECTOR SWITCH IN DOOR
SW - 2 SPEED, 1 WINDING *RP - RED (RUN) PILOT LIGHT IN
DOOR
GP - GREEN (OFF) PILOT LIGHT IN DOOR
RV - REDUCED VOLTAGE AUTOXFMR FA - 4-CONVERTIBLE AUXILIARY CONTACTS
SS - SOLID STATE *TA - TWO CONVERTIBLE
AUXILIARY CONTACTS
EI - ELECTRICAL INTERLOCK (2)-N.O.& (2)-N.C
MD - MOTOR DISCONNECT SWITCH SS - START-STOP PUSHBUTTON IN DOOR
MS - MANUAL STARTER S/N - INSULATED NEUTRAL
ASSEMBLY
HL - HANDLE PADLOCK HASP
MX - MANUAL SWITCH
FDS - FUSED SWITCH
DISCONNECT TYPE & RATING STARTER
ITEM FUSED
NON-
FUSED
CIRCUIT
BREAKER VOLTAGE POLES
NEMA
SIZE TYPE
NEMA
ENCLOSURE REMARKS APPROVED MANUFACTURERS
MS-1 120 1 MS 1 RP, TO SQUARE D 2510 FG1P
CUTLER-HAMMER TYPE MS
GENERAL ELECTRIC CR101
SIEMENS TYPE SMF
LUMINAIRE SCHEDULE
(MTG) MOUNTING: (Type) LAMP TECHNOLOGY: (L/L) LENS/LOUVER:
RE - RECESSED FL - FLUORESCENT A- .125" ACRYLIC
SP - SUSPENDED CF - COMPACT FLUORESCENT B- BLACK BAFFLE
CL - CEILING SURFACE HL - HALOGEN C- CLEAR ALZAK
WL - WALL IN - INCANDESCENT D- PARABOLIC
UC - UNDER CABINET LED - LIGHT EMITTING DIODE F- FRESNEL
CV - COVE HS - HIGH PRESSURE SODIUM G- TEMPERED GLASS
PL - POLE MH - METAL HALIDE H- WALL WASHER
FR- FLANGED RECESSED SMH - SUPER METAL HALIDE P- POLY CARBONATE
O - OTHER ( SEE DESCRIPTION) PSMH - PULSE START METAL HALIDE K- KSH12 .125" ACRYLIC
DOOR: CMH - CERAMIC METAL HALIDE K19- KSH19 .156" ACRYLIC
FA - FLAT ALUMINUM O - OTHER (SEE DESCRIPTION) L- LOW IRIDESCENT SPECULAR ALUM.
FS - FLAT STEEL XL - EXTENDED LIFE N- NONE
RA - REGRESSED ALUMINUM XLP - EXTENDED LIFE & OUTPUT R- HIGH IMPACT DR ACRYLIC
RS - REGRESSED STEEL O- OTHER (SEE DESCRIPTION)
(TYPE) BALLAST: (TYPE) BALLAST:
FINISH: DIM07- LINE DIMMING BALLAST EB- ELECTRONIC BALLAST
PAF - PAINT AFTER FABRICATION DIM10- 0-10V DIMMING BALLAST EM- EMERGENCY BATTERY/BALLAST CSA - FINISH SELECTION BY ARCHITECT HL- HIGH / LOW LEVEL BALLAST DALI- DIGITAL DIMMING BALLAST
ML- MULTI-LEVEL SWITCHING MV- MULTI-VOLTAGE ELECTRONIC 120V-277V
HP- HIGH PERFORMANCE / LBF #BF- BALLAST FACTOR
CATALOG NUMBER SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. THE COMPLETE DESCRIPTION AND THE SPECIFICATION SHALL BE COORDINATED WITH THE CATALOG NUMBER TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE FIRST MANUFACTURER LISTED IS THE
BASIS FOR DESIGN.
REFER TO SPECIFICATION SECTION LIGHTING 26 51 00 FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
ALL LAMPS FOR THIS PROJECT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED.
FLUORESCENT LAMP CORRELATED COLOR TEMPERATURE 4100°K, COLOR RENDERING INDEX (CRI) AT OR ABOVE 80, UNLESS NOTED OTHERWISE.
LED LAMP COLOR RENDERING INDEX (CRI) AT OR ABOVE 85 FOR INTERIOR APPLICATIONS.
ITEM DESCRIPTION
DIMENSIONS LAMPS BALLAST
L/LL W H DIA MTG TYPE QTY MODEL VOLTS TYPE
APPROVED
MANUFACTURER
F1 RECESSED DIRECT WITH HIGH ANGLE
ILLUMINANCE, MATTE ACRYLIC DIFFUSER, TWO
PARALLEL LAMP CHAMBERS.
24" 24" 4.5" RE LED MAX 40
WATT
MINIMUM
4000 LUMEN
MV O LITHONIA VT LED
OR EQUAL BY DAYBRITE OR
COLUMBIA
C.7C.7
EXISTING
WAREHOUSE
1C04B
LIQUID
NITROGEN
STORAGE
114H
MEETING
ROOM
RECEPTION/
WAITING/
FINGER
114G
TRAINING
ROOM 1C04A
ELECTRICAL
114E
OFFICE,
LEAD
SUPER
114D
OFFICE,
CHIEF
114C
OFFICE,
ASST.
CHIEF
114B
OFFICE,
LEAD
SPECIALIST
114A
OFFICE,
LEAD
SPECIALIST
HUMAN
RESOURCES
113A
OFFICE,
PIV
COORD
1C03
CORRIDOR
BCS04
CORRIDOR
1C02
LOBBY
Q
9A
9A
G.1
3.1 5.84.64.2 5.4
J
B
1C01
VESTIBULE
MECHANICAL
EQUIPMENT
ROOM
130A
ELECTRICAL
EQUIPMENT
ROOM
BS11
IV
STORAGE
BS12
WOMEN'S
TOILET
BS14
MEN'S
TOILET
BS13
UNIV
WASTE
HOLDING
BCS05
CORRIDOR
SAFETY
EQUIPMENT
STORAGE
IT
CLOSET
ELEV.
EQUIP.
ROOM109
ELEC
CLST
P-1
ELEVATOR
BREAKROOM
HSKPG
1ST02
EGRESS
STAIR
114F
OFFICE,
LEAD
SUPER
1C04
RECEIVING
A
A2
A4
A6
C
DD
EE
FF
GG
HH
UP
UP
DN
DN
DN
BLD. 2 FIRST FLOOR PLAN - ELECTRICAL DEMOLITION
R T HN O
C.7C.7
EXISTING
WAREHOUSE
1C04B
LIQUID
NITROGEN
STORAGE
114H
MEETING
ROOM
RECEPTION/
WAITING/
FINGER
114G
TRAINING
ROOM 1C04A
ELECTRICAL
114E
OFFICE,
LEAD
SUPER
114D
OFFICE,
CHIEF
114C
OFFICE,
ASST.
CHIEF
114B
OFFICE,
LEAD
SPECIALIST
114A
OFFICE,
LEAD
SPECIALIST
HUMAN
RESOURCES
113A
OFFICE,
PIV
COORD
1C03
CORRIDOR
BCS04
CORRIDOR
1C02
LOBBY
Q
9A
9A
G.1
3.1 5.84.64.2 5.4
J
B
1C01
VESTIBULE
MECHANICAL
EQUIPMENT
ROOM
130A
ELECTRICAL
EQUIPMENT
ROOM
BS11
IV
STORAGE
BS12
WOMEN'S
TOILET
BS14
MEN'S
TOILET
BS13
UNIV
WASTE
HOLDING
BCS05
CORRIDOR
SAFETY
EQUIPMENT
STORAGE
IT
CLOSET
ELEV.
EQUIP.
ROOM109
ELEC
CLST
P-1
ELEVATOR
BREAKROOM
HSKPG
1ST02
EGRESS
STAIR
114F
OFFICE,
LEAD
SUPER
1C04
RECEIVING
A
A2
A4
A6
C
DD
EE
FF
GG
HH
UP
UP
DN
DN
DN
BLD. 2 FIRST FLOOR PLAN - POWER & SYSTEMS
R T HN O
BLD. 7 FIRST FLOOR PLAN - ELECTRICAL DEMOLITION
| 636A8.14-006.X-001 |
| 636A8.14-006.GI001 |
| 04-636A8-14-006 Elect |
| 1-E0-00 COVER SHEET |
| 1-ED1-00 SUB-BASEMENT FLOOR PLAN - ELECTRICAL DEMOLITION |
| 1-ED1-0E BE FLOOR PLAN - ELECTRICAL DEMOLITION |
| 1-ED1-0S BS FLOOR PLAN - ELECTRICAL DEMOLITION |
| 1-ED1-0W BW FLOOR PLAN - ELECTRICAL DEMOLITION |
| 1-ED1-1E 1E FLOOR PLAN - ELECTRICAL DEMOLITION |
| 1-ED1-3S 3S FLOOR PLAN - ELECTRICAL DEMOLITION |
| 1-ED1-5S 5S FLOOR PLAN - ELECTRICAL DEMOLITION |
| 1-ED1-8W 8W FLOOR PLAN - ELECTRICAL DEMOLITION |
| 1-ED1-11W 11W PENTHOUSE - ELECTRICAL DEMOLITION |
| 1-E1-8W 8W FLOOR PLAN - LIGHTING |
| 1-E2-00 SUB-BASEMENT FLOOR PLAN - POWER & SYSTEMS |
| 1-E2-0S BS FLOOR PLAN - POWER & SYSTEMS |
| 1-E2-1E 1E FLOOR PLAN - POWER & SYSTEMS |
| 1-E2-5S 5S FLOOR PLAN - POWER & SYSTEMS |
| 1-E2-8W 8W FLOOR PLAN - POWER & SYSTEMS |
| 1-E2-11W 11W PENTHOUSE PLAN - POWER & SYSTEMS |
| 1-E3-01 ELECTRICAL DETAILS |
| 2-ED1-01 BLD. 2 FIRST FLOOR PLAN - ELECTRICAL DEMOLITION |
| 2-E1-01 BLD. 2 FIRST FLOOR PLAN - POWER & SYSTEMS |
| 7-ED1-01 BLD. 7 FIRST FLOOR PLAN - ELECTRICAL DEMOLITION |
File details come from the government source that posted it.