ASBESTOS GENERAL NOTES
ASB1
ASBESTOS GENERAL NOTES
SUB-BASEMENT ABATEMENT PLAN
R
T
H
N
O
1-ASB1-00
SUB-BASEMENT ABATEMENT PLAN
TAG AH1-B1
PH Coil 150 LB/HR RH Coil N/A
Humd 45 LB/HR
TAG AH1-B4
PH Coil NONE RH Coil NONE
Humd NONE
TAG AH1-B2
PH Coil 130 LB/HR RH Coil N/A
Humd 50 LB/HR
BASEMENT EAST ABATEMENT PLAN
SCALE: 1/8"=1'-0"
1-ASB1-0E
BASEMENT EAST ABATEMENT PLAN
R
T
H
N
O
TAG AH1-B7
PH Coil 171 RH Coil N/A
Humd N/A
R T
H
N
O
1-ASB1-0S
BASEMENT SOUTH ABATEMENT PLAN
BASEMENT SOUTH ABATEMENT PLAN
SCALE: 1/8"=1'-0"
BASEMENT SOUTHWEST
ABATEMENT PLAN
BASEMENT SOUTHWEST ABATEMENT PLAN
SCALE: 1/8"=1'-0"
R
T
H
N
O
1-ASB1-0SW
TAG AH1-B5
PH Coil 550 LB/HR RH Coil N/A
Humd N/A
TAG AH1-B6
PH Coil 719 LB/HR RH Coil 315 LB/HR
Humd 195 LB/HR
BASEMENT WEST ABATEMENT PLAN
SCALE: 1/8"=1'-0"
R
T
H
N
O
1-ASB1-0W
BASEMENT WEST ABATEMENT PLAN
1-ASB1-1E
1E ABATEMENT PLAN
1E ABATEMENT PLAN
SCALE: 1/8"=1'-0"
R
T
H
N
TAG AH1-12
PH Coil 960 lb/h
RH Coil WATER
Humd N/A
1-ASB1-1S
1S ABATEMENT PLAN
1S ABATEMENT PLAN
SCALE: 1/8"=1'-0"
R
T
H
N
1-ASB1-1SW
1SW ABATEMENT PLAN
1SW ABATEMENT PLAN
SCALE: 1/8"=1'-0"
R
T
H
N
1-ASB1-1W
1W ABATEMENT PLAN
1W ABATEMENT PLAN
SCALE: 1/8"=1'-0"
R
T
H
N
1-ASB1-2E
2E ABATEMENT PLAN
2E ABATEMENT PLAN
SCALE: 1/8"=1'-0"
R
T
H
N
1-ASB1-2S
2S ABATEMENT PLAN
2S ABATEMENT PLAN
SCALE: 1/8"=1'-0"
R
T
H
N
1-ASB1-2SW
2SW ABATEMENT PLAN
2SW ABATEMENT PLAN
SCALE: 1/8"=1'-0"
R
T
H
N
1-ASB1-2W
2W ABATEMENT PLAN
2W ABATEMENT PLAN
SCALE: 1/8"=1'-0"
R T
H
N
1-ASB1-3E
3E ABATEMENT PLAN
3E ABATEMENT PLAN
SCALE: 1/8"=1'-0"
R
T
H
N
TAG AH1-32
PH Coil 393 lb/h
RH Coil 492 lb/h
Humd 281 lb/h
TAG AH1-33
PH Coil 615 lb/h
RH Coil N/A
Humd 81 lb/h
TOTAL
R
T
H
N
O
3S ABATEMENT PLAN
SCALE: 1/8"=1'-0"
1-ASB1-3S
3S ABATEMENT PLAN
TAG AH1-39
PH Coil N/A
RH Coil N/A
Humd 85 lb/h
TAG AH1-36
PH Coil 810 lb/h RH Coil N/A (Water)
Humd 245 lb/h
TAG AH1-38
PH Coil 1520 LB/H
RH Coil WATER
Humd 435 LB/H
TAG AH1-37
PH Coil 3800 LB/H
RH Coil WATER
Humd 1150 LB/H
R
T
H
N
O
3SW ABATEMENT PLAN
SCALE: 1/8"=1'-0"
1-ASB1-3SW
3SW ABATEMENT PLAN
TAG AH1-35
PH Coil 284 lb/h
RH Coil 203 lb/h
Humd 116 lb/h
TAG AH1-34
PH Coil 48 lb/h
RH Coil 24 lb/h
HX 90 lb/h
3W ABATEMENT PLAN
SCALE: 1/8"=1'-0"
R T
H
N
O
1-ASB1-3W
3W ABATEMENT PLAN
| 636A8.14-006.X-001 |
| 636A8.14-006.GI001 |
| 01-636A8-14-006 Env |
| 1-ASB1 |
| 1-ASB1-00 |
| 1-ASB1-0E |
| 1-ASB1-0S |
| 1-ASB1-0SW |
| 1-ASB1-0W |
| 1-ASB1-1E |
| 1-ASB1-1S |
| 1-ASB1-1SW |
| 1-ASB1-1W |
| 1-ASB1-2E |
| 1-ASB1-2S |
| 1-ASB1-2SW |
| 1-ASB1-2W |
| 1-ASB1-3E |
| 1-ASB1-3S |
| 1-ASB1-3SW |
| 1-ASB1-3W |
| 1-ASB1-4E |
| 1-ASB1-4S |
| 1-ASB1-4SW |
| 1-ASB1-4W |
| 1-ASB1-5E |
| 1-ASB1-5S |
| 1-ASB1-5W |
| 1-ASB1-6E |
| 1-ASB1-6S |
| 1-ASB1-6W |
| 1-ASB1-7E |
| 1-ASB1-7W |
| 1-ASB1-8E |
| 1-ASB1-8W |
| 1-ASB1-9E |
| 1-ASB1-9W |
| 1-ASB1-10E |
| 1-ASB1-10W |
| 1-ASB1-11E |
| 1-ASB1-11W |
| 1-ASB1-12 |
| 2-ASB1-01 |
| 7-ASB1-01 |
File details come from the government source that posted it.