PG601_amended_signed.pdf
PDF 3 MB Posted
- Attached to
- Y1LZ--573-339 BB Expand Vertical Parking Garage #2 (Independence) Minor Construction - Gainesville VAMC
- Solicitation number
- 36C77625B0001
About this file
This is a sign schedule drawing showing specifications for parking garage vehicular signage at what appears to be a VA medical facility. The document details various types of signs including directional, level indicators, stair/elevator markers, and safety signage, with specific information about mounting heights, colors, and installation details for each sign type.
The schedule includes specifications for over 25 different signs (S6 through S41) with details such as sign type codes (PS and IN prefixes), text/messaging requirements, mounting specifications, and size requirements. Key specifications include the use of Helvetica Medium font for most signs and Helvetica Condensed Medium for overhead signs, mounting heights ranging from 2'-0" to 7'-8", and color coding by level for certain signs. The document includes general notes about installation requirements, such as coordination with lighting systems, level/plumb mounting requirements, and maximum bolt insert embedment lengths of 1-1/4" into concrete structures.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SIGN SCHEDULE
REMARKSMARK SIGN TYPE
SIZE
TEXT/MESSAGE
MOUNTING
DETAIL HT.COLOR
BACKGROUND TEXT
COLOR
B12StairPS-01.04A 7'-8"S6 PS INSTALLATION DETAIL 1T2 4'-6" AT LONG SIGN
B12Elevator / StairPS-01.04B 7'-8"S7 PS INSTALLATION DETAIL 1T2 4'-6" AT LONG SIGN
*Elevator / Stair / Level 5PS-03.01B 5'-0"S8 PS INSTALLATION DETAIL 4* * COLOR BY LEVEL
*Stair / Level 5PS-03.01B 5'-0"S9 PS INSTALLATION DETAIL 4* * COLOR BY LEVEL
-In Case of Fire .......IN-01.04 5'-0"S10 PS INSTALLATION DETAIL 4-
B3Fire EquipmentIN-01.31 7'-0"S11 LS INSTALLATION DETAIL 13T1 TYP. ALL FIRE EXTINGUISHERS
B8Watch for PedestriansPS-04.01 2'-0"S12 PS INSTALLATION DETAIL 4T4
*1, 2, 3, 4, 5PS-07.02 4'-0"S13 SURFACE APPLIED VINYLT2 * COLOR BY LEVEL
*Level 1, 2, 3, 4, 5PS-05.01 5'-0"S14 PS INSTALLATION DETAIL 4* * COLOR BY LEVEL
*Level 5PS-05.05 8'-0"S15 * * COLOR BY LEVEL
* TOP @ 4'-0" @ TOP LEVEL
B19ParkPS-01.04A 7'-8"S18B T2 PS INSTALLATION DETAIL 1
B19OutPS-01.04A 7'-8"S19A T2 PS INSTALLATION DETAIL 1
B19OutPS-01.04A 7'-8"S19B T2 PS INSTALLATION DETAIL 1
*Stair No 3 Exit Down........IN-01.11A 5'-0"S26 T1 LS INSTALLATION DETAIL 7
*IN-01.11C 5'-0"S26A T1 LS INSTALLATION DETAIL 7Stair No 3 Exit Level
* COLOR BY LEVEL
* COLOR BY LEVEL
Exit to Freedom Parking Garage S39A
S39B Exit to Freedom Parking Garage
B19 7'-8"T2 PS INSTALLATION DETAIL 1
B19 7'-8"T2 PS INSTALLATION DETAIL 1
Exit to Independence Parking Garage S40A
S40B Exit to Independence Parking Garage
B19 7'-8"T2 PS INSTALLATION DETAIL 1
B19 7'-8"T2 PS INSTALLATION DETAIL 1
PS-01.04B
PS-01.04B
PS-01.04B
PS-01.04B
B19ParkPS-01.04A 7'-8"S18A T2 PS INSTALLATION DETAIL 1
B19ParkPS-01.04A 7'-8"S18C T2 PS INSTALLATION DETAIL 1
B19OutPS-01.04A 7'-8"S19C T2 PS INSTALLATION DETAIL 1
S39C Exit to Freedom Parking Garage B19 7'-8"T2 PS INSTALLATION DETAIL 1PS-01.04B
S40C Exit to Independence Parking Garage B19 7'-8"T2 PS INSTALLATION DETAIL 1PS-01.04B
B7/B3PS-04.01 7'-8"S41 T4 SEE DETAIL 1/PG610Do Not Enter
B19OutPS-01.04A 7'-8"S19D T2 PS INSTALLATION DETAIL 1
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 10
A
B
C
D
E
F
AKEA Design, Inc.
3603 NW 98th Street, Suite B Gainesville, FL 32606 Phone: (352) 474-6124
COA: FL #29758
AKEA Project No. AD217-23
Design, Inc.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseARCHITECT / ENGINEER OF RECORDCONSULTANT EXPAND VERTICAL
PARKING GARAGE II
(INDEPENDENCE GARAGE)
573-339
VAMC GAINESVILLE, FLORIDAThis item has been electronically signed and sealed by the individual named at right.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
ENGINEER - OF - RECORD FL. P.E. NO.
WALKER CONSULTANTS SEAL
OF
GARAGE 2
FINAL
CONSTRUCTION DOCUMENTS
MALCOM RANDALL VAMC
1601 SW ARCHER ROAD
GAINESVILLE, FLORIDA 32608
Walker Consultants 4925 Independence Pkwy, Suite 425 Tampa, FL 33634 Phone: (813) 888-5800
FINAL CONSTRUCTION DOCUMENTS
APPROVED FOR CONSTRUCTION
DAG Architects 40 S. Palafox, Suite 201 Pensacola, FL 32502 Phone: (850) 429-9004
1/ /2 9:
:2
AM
Au to de sk D oc s:
//A D 7- -0 5.
V
AM
C
IN
D
EP
EN
D
EN
C E
PA
R
KI
N G G
AR
AG
E
VE
R
TI
C
AL
E
XP
AN
SI
O N /V
AM
C _I nd ep en de nc e_
PG
_V er tic al _E xp an si on _R .rv t
MLC GFT03/22/2024
PG601
SIGN SCHEDULE AND
COMPONENTS
MATTHEW L. CONLEY 86467
53 123
GARAGE VEHICULAR SIGNAGE GENERAL NOTES:
1. LETTER FORMS SHALL BE HELVETICA MEDIUM, PER VA ADMINISTRATION STANDARDS. UPPER AND LOWER CASE SHALL BE USED ON ALL DIRECTIONAL TRAFFIC AND PEDESTRIAN SIGNS, UNLESS NOTED. HELVETICA CONDENSED MEDIUM FOR ALL OVERHEAD SIGNS.
2. SIGN CONTRACTOR SHALL REVIEW SIGN LOCATIONS PRIOR TO INSTALLATION WITH ENGINEER TO COORDINATE WITH LIGHTING SYSTEM, SIGN AND LIGHT LOCATIONS PER SPECIFICATIONS.
3. SIGNS SHALL BE MOUNTED LEVEL AND PLUMB, UNLESS NOTED.
4. WHERE TWO (2) SIGNS ARE MOUNTED BACK TO BACK, SMALLEST L DIMENSION SHALL INCREASE TO MATCH LARGEST L DIMENSION.
5. MAXIMUM BOLT INSERT EMBEDMENT LENGTH 1-1/4" INTO CONCRETE STRUCTURE, UNLESS NOTED.
6. DO NOT SCALE DRAWINGS.
7. BACKS AND EDGES OF ALL ALUMINUM SIGNS MOUNTED DIRECTLY TO STRUCTURE SHALL BE PAINTED WHITE TO PREVENT CATHODIC REACTION.
8. SEE PG101 THRU PG103 PLANS FOR PARKING LAYOUT AND SIGN LOCATIONS.
9. ILLUMINATED SIGNS TO BE U.L. LISTED OR APPROVED EQUIVALENT.
10. REFLECTIVE GRAPHICS AND COPY COLORS ARE 3M. ALL NON-REFLECTIVE COLORS ARE PANTONE OR EQUAL TO SHERWIN WILLIAM.
11. SEE DEPARTMENT OF VETERANS AFFAIRS SIGNAGE DESIGN GUIDE, PG-18-12 FOR ADDITIONAL INFORMATION INCLUDING SIGN TYPE, SIZE, COLORS AND MOUNTING DETAILS NOTED IN
SCHEDULE ABOVE.
12. HANG SIGN FROM OUTSIDE FACE OF BEAM.
13. HEIGHT OF SIGNS AS INDICATED IS TO THE BOTTOM OF THE SIGN.
Revisions: Date:
ADDENDUM #1 01.20.25
| 2025-01-24T07:00:39-0500 | |
| Matthew L Conley | |
| I have reviewed this document |
File details come from the government source that posted it. Updated .