Amendment0003 - Attachment 28 - 550-319 Drawings Set_Part 7 Full Size.pdf

PDF 13 MB Posted

Attached to
Y1DZ--Minor Construction - Danville VAMC - 550-319 Construct Two New Homes 7 & 8
Solicitation number
36C77624B0020
Issued by

About this file

This document is Amendment 0003 to the Solicitation for the construction of two new homes at the Danville VA Medical Center. The solicitation number is 36C77624B0020 and the project is named "Y1DZ--Minor Construction - Danville VAMC - 550-319 Construct Two New Homes 7 & 8".

The key details are:

  • This is a solicitation for minor construction to build two new homes at the Danville VAMC.
  • All questions must be submitted via email to the specified points of contact by July 26, 2024 at 2:00pm EDT.
  • Bids must be submitted via email to the three points of contact on August 13, 2024 at 2:00pm EDT.
  • The Department of Veterans Affairs Technology Acquisition Center Austin is the federal agency managing this contract opportunity.

View the file

Other files

File Type Posted
Amendment0005 - Attachment 34 - SF102.pdf PDF
Amendment0005 - Attachment 33 - Structural Bidding Addendum Set.pdf PDF
Amendment0005 - Attachment 35 - WD - IL - IL20240002 - 8-09-2024.pdf PDF
36C77624B002_Amendment0005.pdf PDF
36C77624B0020_Amendment0004.pdf PDF
Amendment0003 - Attachment 24 - 550-319 Drawings Set_Part 3 Full Size.pdf PDF
Amendment0003 - Attachment 26 - 550-319 Drawings Set_Part 5 Full Size.pdf PDF
Amendment0003 - Attachment 31 - 60 Master.pdf PDF
Amendment0003 - Attachment 22 - 550-319 Drawings Set_Part 1 Full Size.pdf PDF
36C77624B0020_Amendment0003.pdf PDF
Amendment0003 - Attachment 21 - Danville Technical Questions and VA Responses.pdf PDF
Amendment0003 - Attachment 27 - 550-319 Drawings Set_Part 6 Full Size.pdf PDF
Amendment0003 - Attachment 32 - Facility Map.pdf PDF
Amendment0003 - Attachment 23 - 550-319 Drawings Set_Part 2 Full Size.pdf PDF
Amendment0003 - Attachment 29 - 550-319 Drawings Set_Part 8 Full Size.pdf PDF
Amendment0003 - Attachment 30 - Section 01 45 00 - Quality Control.pdf PDF
Amendment0003 - Attachment 25 - 550-319 Drawings Set_Part 4 Full Size.pdf PDF
Amendment0002_Attachment 20 - WD - IL - IL20240002 - 08-02-2024.pdf PDF
36C77624B0020 _Amendment0002.pdf PDF
Amendment0001_ Attachment 19 - 550-319 - Site Visit Sign-in Sheet.pdf PDF
36C77624B0020_Amendment 0001.pdf PDF
Attachment 12 - 550-319 Geotechnical Report_Part2.pdf PDF
Attachment 16 - WD - IL - IL20230002 - 07-05-2024.pdf PDF
Attachment 7 - 550-319 Construction Drawings Set_Part5.pdf PDF
Attachment 1 - 550-319 100pct Specifications Vol 1_rev.pdf PDF
Attachment 11 - 550-319 Geotechnical Report_Part1.pdf PDF
Attachment 4 - 550-319 Construction Drawings Set_Part2.pdf PDF
Attachment 10 - 550-319 Construction Drawings Set_Part8.pdf PDF
Attachment 5 - 550-319 Construction Drawings Set_Part3.pdf PDF
Attachment 3 - 550-319 Construction Drawings Set_Part1.pdf PDF
Attachment 2 - 550-319 100pct Specifications Vol 2_rev.pdf PDF
Attachment 15 - Brand Name JA - Danville - signed.pdf PDF
36C77624B0020.pdf PDF
Attachment 8 - 550-319 Construction Drawings Set_Part6.pdf PDF
Attachment 14 - 019100-General-Commissioning-Reqt.pdf PDF
Attachment 17 - Limitations on Subcontracting - Construction.pdf PDF
Attachment 18 - Previous RFIs - VA Responses.pdf PDF
Attachment 13 - 550-319 Geotechnical Report_Part3.pdf PDF
Attachment 9 - 550-319 Construction Drawings Set_Part 7.pdf PDF
Attachment 6 - 550-319 Construction Drawings Set_Part4.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OVEN

DW

DN

UP

BASIS OF DESIGN

MOUNT AT 5'-1" AFF TO BOTTOM OF SIGN

1' - 8"

1'

3'

2' - 0"

BASIS OF DESIGN.

MOUNT AT 6'-6" AFF TO TOP OF SIGN.

2'

1' - 6"

BASIS OF DESIGN.

MOUNT AT 6'-6" AFF TO TOP OF SIGN.

BASIS OF DESIGN.

MOUNT CENTERED ABOVE FIRE

EXTINGUISHER CABINET AT 7'-0" AFF TO

BOTTOM OF SIGN

9"

9"

9"

9"

BASIS OF DESIGN.

MOUNT CENTERED ON DOOR

AT 5'-3" AFF TO TOP OF SIGN

9"

9"

BASIS OF DESIGN.

MOUNT CENTERED ON DOOR

AT 5'-3" AFF TO TOP OF SIGN

9"

9"

BASIS OF DESIGN.

MOUNT AT 5'-0" AFF

TO TOP OF SIGN

BASIS OF DESIGN.

MOUNT AT 5'-0" AFF

TO TOP OF SIGN

3"

9"

/4

9"

BASIS OF DESIGN.

MOUNT AT 5'-0" AFF

TO TOP OF SIGN

108 SF

VESTIBULE

(BSVT5)

452 SF

GARAGE

(BSGR1)

134 SF

STORAGE

(STGN2)

18 SF

O2 STORAGE

474 SF

SCREENED PORCH

(PSPH1)

864 SF

DINING

(PSDR3)

398 SF

KITCHEN

(RHKN4)80 SF

PANTRY

(CSPY1)

194 SF

DEN

(PSDN2)

69 SF

VESTIBULE

(BSVT5)

107 SF

BATH

19A

(TPG01)

167 SF

SPA

19B

(BTSH1)

51 SF

TOILET

(TNPG1)

52 SF

TOILET

27B

(TNPG1) 175 SF

STAFF LOUNGE

(LGST2)

71 SF

SOILED HOLDING

(CSUS3)

48 SF

JANITOR

(HAC)

90 SF

CLEAN SUPPLY

(CSUC1)

61 SF

MEDICATION

(CSMR1)

60 SF

CLEAN LINEN

(STCL1)

60 SF

HOUSEKEEPING

(BSHC1)

100 SF

EQUIP. STORAGE

(STMQ2)

88 SF

LAUNDRY

(LAU05)

94 SF

OFFICE

(OFF02)

5 SF

CHARTING

188 SF

CORRIDOR / STORM

SHELTER

FIREPLACE

FIREPLACE

95 SF

BATHROOM

23B

(TSPB1)

253 SF

BEDROOM

(BSHM1)

10 SF

CLOSET

23A

(CASC1)

119 SF

BATHROOM

22B

(TSPB1)

265 SF

BARIATRIC

(BSHM1)

9 SF

CLOSET

22A

(CASC1)

98 SF

BATHROOM

21B

(TSPB1)

298 SF

BEDROOM

(BSHM1)

9 SF

CLOSET

21A

(CASC1)

231 SF

BEDROOM

(BSHM1)

94 SF

BATHROOM

20B

(TSPB1)

9 SF

CLOSET

20A

(CASC1)

238 SF

BEDROOM

(BSHM1)

95 SF

BATHROOM

11B

(TSPB1)

8 SF

CLOSET

11A

(PSCL1)

9 SF

CLOSET

12A

(PSCL1)

95 SF

BATHROOM

12B

(TSPB1)

238 SF

BEDROOM

(BSHM1)

238 SF

BEDROOM

(BSHM1)

95 SF

BATHROOM

13B

(TSPB1)

95 SF

BATHROOM

14B

(TSPB1)

238 SF

BEDROOM

(BSHM1)

9 SF

CLOSET

13A

(PSCL1)

9 SF

CLOSET

14A

(PSCL1)

400 SF

CORRIDOR

69 SF

VESTIBULE

(BSVT5)

93 SF

BATH

17B

(TSPB1)

237 SF

BEDROOM

(BSHM1)

237 SF

BEDROOM

(BSHM1)

94 SF

BATH

16B

(TSPB1)

53 SF

STORAGE

M8

35 SF

MECHANICAL

CLOSET

M12

47 SF

MECHANICAL

CLOSET

M11

FD

FD

FD

FD

FD FD

FD

FD

FD

FD

FD

IN-04.03 IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-08.02

IN-08.02

IN-03.01

IN-09.03

IN-09.03

IN-04.03 IN-04.03 IN-04.03

IN-04.03IN-04.03IN-04.03

IN-04.03 IN-04.03

IN-08.02

IN-04.03

IN-03.01

IN-04.03

IN-04.03

IN-08.02

IN-08.02 IN-08.02

IN-01.22

IN-04.03

IN-04.03

IN-02.08

IN-02.01

IN-02.07

A. THE SIGNAGE VENDOR SHALL PROVIDE SHOP DRAWINGS FOR ALL NEW

SIGNS TO BE REVIEWED AND APPROVED BY THE VA PRIOR TO FABRICATION.

B. ALL SIGNAGE INDICATED IS A BASIS OF DESIGN. ALL CONTENT,

MODIFICATIONS, AND VERBIAGE ARE TO BE DETERMINED BY THE VA PRIOR

TO FABRICATION.

C. WHEN EXISTING SIGNAGE IS REMOVED CONTRACTOR SHALL REPAIR ANY

DAMAGE TO SUBSTRATE AND MATCH FINISHES PRIOR TO THE INSTALLATION

OF NEW OR SALVAGED SIGNAGE.

D. SIGNAGE SHOULD BE INSTALLED TO COMPLY WITH ALL APPLICABLE CODES.

ALL TACTILE ROOM NUMBER SIGNS OR OTHER TACTILE ROOM

IDENTIFICATION SIGNS ARE REQUIRED TO MEET ABA/ADA REQUIREMENT

FOR HEIGHT AND BRAILLE TEXT.

SIGNAGE GENERAL NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.5

G re e n

H o m e s v d c h ri s te n s e n M

N F

X

.r v t

/1

/2

:4

:2

A

M

AI901

SIGNAGE PLAN

GUIDON DESIGN, INC.

1221 N. Pennsylvania Street

Indianapolis, Indiana 46202

317.800.6388

CMTA

10411 Meeting Street

Prospect, Kentucky 40059

502.326.3085

CONSTRUCT TWO NEW GREEN

HOMES 7 & 8

1900 E. MAIN ST., DANVILLE, IL 61832

550-319

7 & 8

04/09/2020 JF LC

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

SCALE: 3" = 1'-0"AI901

1 IN-02.01

SCALE: 3" = 1'-0"AI901

2 IN-02.07

SCALE: 3" = 1'-0"AI901

3 IN-02.08

SCALE: 3" = 1'-0"AI901

4 IN-01.02

SCALE: 3" = 1'-0"AI901

5 IN-08.02

SCALE: 3" = 1'-0"AI901

6 IN-01.22

SCALE: 3" = 1'-0"AI901

7 IN-04.03

SCALE: 3" = 1'-0"AI901

9 IN-03.01

SCALE: 3" = 1'-0"AI901

12 IN-09.03

SCALE: 1/8" = 1'-0"AI901

15 SIGNAGE PLAN

Revisions: Date:

R E

F

OVEN

R E

F

DW

UP

DN

EQUIPMENT GENERAL NOTES

A. PROVIDE BLOCKING IN WALLS TO ACCOMMODATE EQUIPMENT,

FURNISHINGS, TECHNOLOGY AND WALL MOUNTED ACCESSORIES.

B. REFER TO SHEET QH101 FOR EQUIPMENT SCHEDULE.

C. REFER TO SHEET AI601 FOR FINISH SCHEDULE.

D. REFER TO SHEET AI201 FOR TOILET ACCESSORY INFORMATION AND FOR

TOILETS AND SINK LOCATIONS.

E. REFER TO SHEET QH101 FOR EQUIPMENT PLAN.

F. REFER TO SHEET AE200 SERIES FOR ENLARGED TOILET PLANS & INTERIOR

ELEVATION.

G. COORDINATE EQUIPMENT LOCATION, WATER REQUIREMENTS, POWER AND

DATA EQUIPMENTS WITH EQUIPMENT AND ENGINEERING DRAWINGS.

VESTIBULE

(BSVT5)

GARAGE

(BSGR1)

STORAGE

(STGN2)

O2 STORAGE

SCREENED PORCH

(PSPH1)

LIVING ROOM

(PSLR3)

DINING

(PSDR3)

KITCHEN

(RHKN4)

PANTRY

(CSPY1)

DEN

(PSDN2)

VESTIBULE

(BSVT5)

BATH

19A

(TPG01)

SPA

19B

(BTSH1)

TOILET

(TNPG1)

TOILET

27B

(TNPG1)

STAFF LOUNGE

(LGST2)

SOILED HOLDING

(CSUS3)

JANITOR

(HAC)

CLEAN SUPPLY

(CSUC1)

MEDICATION

(CSMR1)

CLEAN LINEN

(STCL1)

HOUSEKEEPING

(BSHC1) EQUIP. STORAGE

(STMQ2)

LAUNDRY

(LAU05)

OFFICE

(OFF02)

CHARTING

CORRIDOR / STORM

SHELTER

FIREPLACE

FIREPLACE

BATHROOM

23B

(TSPB1)

BEDROOM

(BSHM1)

CLOSET

23A

(CASC1)

BATHROOM

22B

(TSPB1)

BARIATRIC

(BSHM1)

CLOSET

22A

(CASC1)

BATHROOM

21B

(TSPB1)

BEDROOM

(BSHM1)

CLOSET

21A

(CASC1)

BEDROOM

(BSHM1)

BATHROOM

20B

(TSPB1)

CLOSET

20A

(CASC1)

BEDROOM

(BSHM1)

BATHROOM

11B

(TSPB1)

CLOSET

11A

(PSCL1)

CLOSET

12A

(PSCL1)

BATHROOM

12B

(TSPB1)

BEDROOM

(BSHM1)

BEDROOM

(BSHM1)

BATHROOM

13B

(TSPB1)

BATHROOM

14B

(TSPB1)

BEDROOM

(BSHM1)

CLOSET

13A

(PSCL1)

CLOSET

14A

(PSCL1)

CORRIDOR

VESTIBULE

(BSVT5)

STORAGE

M8

BATH

16B

(TSPB1)

BATH

17B

(TSPB1)

BEDROOM

(BSHM1)

BEDROOM

(BSHM1)

QH201

QH202

F0255

F0740 F0375

F0736

F2000

QH202

F0225

F0600

QH202

QH201

QH201

QH201

QH202

F1000

QH201

QH201

QH202

QH201

QH201

QH201

QH201

MECHANICAL

CLOSET

M11

MECHANICAL

CLOSET

M12

M2050

M2050

M2050

FD

FD

FD

FD

F D

F D

FD

FD

FD

FD

M3000

F2300 F2400

F4100

F2401

F2200

AI204

AI202

1 2

AI202

AI203

AI203

AI204

AE501

AE501

AE204

AE204

AE202

AE202

AE205

F2200

QH202

F4100

RESPONSIBLE PARTY LEGEND

FFE

CC CONTRACTOR FURNISHED / CONTRACTOR INSTALLED

VC VA FURNISHED / CONTRACTOR INSTALLED

VV VA FURNISHED / VA INSTALLED

VC(CF) VA FURNISHED WITH CONSTRUCTION FUNDS / CONTRACTOR INSTALLED

VV(CF) VA FURNISHED WITH CONSTRUCTION FUNDS / VA INSTALLED

R RELOCATE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.5

G re e n

H o m e s v d c h ri s te n s e n M

N F

X

.r v t

/1

/2

:4

:5

A

M

QH101

EQUIPMENT FLOOR PLAN &

SCHEDULEGUIDON DESIGN, INC.

1221 N. Pennsylvania Street

Indianapolis, Indiana 46202

317.800.6388

CMTA

10411 Meeting Street

Prospect, Kentucky 40059

502.326.3085

CONSTRUCT TWO NEW GREEN

HOMES 7 & 8

1900 E. MAIN ST., DANVILLE, IL 61832

550-319

7 & 8

04/09/2020 JF DMC

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/8" = 1'-0"QH101

1 FIRST FLOOR EQUIPMENT PLAN

N

EQUIPMENT SCHEUDLE

Mark Description

FFE

FURNISHED Comments

A1015 TELEPHONE, DESK VV

A1030 LOCKER, STAFF VV

A1085 MIRROR, FLOAT CC

A1205 LIFT SYSTEM, OVERHEAD CC

A5048 CABINET, MEDICATION CC

A5075 DISPENSER, SOAP VC

A5076 DISPENSER, HAND SANITIZER VC

A5080 DISPENSER, PAPER TOWEL VC

A5106 SHARPS, w/GLOVES VV

A5107 DISPENSER, GLOVES VV

A5109 GRAB BAR, 1.25" DIA., SHOWER CC

A5115 GRAB BAR, FLIP-UP CC

A5135 SHELF w/ROD, UTILITY CC

A5145 HOOK, GARMENT CC

A5161 SHELF, UTILITY CC

A5170 ROD, SHOWER CURTAIN CC

A5200 DISPENSER, TOILET TISSUE CC

A5205 BAR, TOWEL CC

A5212 BRACKET, WALL MOUNTED VV

A6046 ARTWORK, DECORATIVE VV

CB061 CABINET, PERSONAL ITEMS VV

E0210 WORKSPACE w/OVERHEAD CABINET VV

F0210 SIDE CHAIR w/o ARMS VV

F0225 CHAIR, DINING VV

F0255 CHAIR, EASY VV

F0275 CHAIR, SWIVEL VV

F0280 CHAIR, SWIVEL VV

F0321 CHAIR, SALON VV

F0370 SOFA, SLEEPER, UPHOLSTERED VV

F0375 SOFA VV

F0400 CABINET, BEDSIDE VV

F0420 CABINET, FILING VV

F0600 CREDENZA VV

F0710 TABLE, COMPUTER VV

F0736 TABLE, COFFEE VV

F0740 TABLE, LAMP VV

F1000 TABLE, DINING VV

F2000 WASTEPAPER VV

F2010 WASTEPAPER, STEP-ON VV

F2015 BASKET, WASTEAPER VV

F2020 TRASH CAN, 44 GALLON VV

F2200 PATIO CHAIR VV

F2300 PATIO SOFA VV

F2400 PATIO TABLE, 36" VV

F2401 PATIO TABLE, 60" VV

F2420 LAMP, TABLE VV

F3010 MARKER BOARD, 4'x6' VV

F3200 CLOCK VV

F4100 TABLE w/CHAIRS, OUTDOOR VV

K1552 COFFEE BREWER, 3 BURNER VV

K4000 HOOD, EXHAUST CC

K4500 STOVETOP, 4 BURNER CC

K4502 OVEN, DOUBLE, RECESSED CC

K4665 MICROWAVE VV

K8250 TOASTER VV

M0430 DVD PLAYER VV

M0506 TELEVISION, FLAT VV

M0755 FLOWMETER, OXYGEN VV

M1200 WARMER, BLANKET VV

M1801 COMPUTER, FLAT VV

M1825 PRINTER, WRISTBAND VV

M1840 PRINTER/COPIER/FAX VV

M2050 SHELVING, STORAGE, WIRE VV

M2055 SHELVING, STORAGE, WIRE VV

M2300 WASHER, FRONT LOAD VV

M2400 DRYER, ELECTRIC, FRONT LOAD VV

M3000 ELECTRIC HOIST, 1 TON, 20' LIFT, 1 HP

MIN., 16' PER MINUTE SPEED

CC 1 1/4" HOOK OPENING w/ 3000#

CAPACITY TROLLEY

M3070 HAMPER, LINEN, MOBILE VV

M3072 FRAME, INFECTIOUS WAST BAG w/LID VV

M3150 DISTRIBUTION, MEDICATION VV

M4208 CHAIR, SHOWER, BARIATRIC VV

M4802 CHAIR, SHOWER, BARIATRIC VV

M7011 BED VV

M7012 BARIATRIC BED VV

P2000 EYE WASH STATION CC

P2450 VALVE, MIXING CC

P4700 SINK, MOP CC

P5040 SHOWER, HAND-HELD CC

P6505 SINK, LAUNDRY CC

R1000 REFRIDGERATOR, PANTRY VV

R3000 REFRIGERATOR, FRENCH DOOR VV

R3100 DISHWASHER CC

R4650 DISPENSER, ICE VV

R6200 REFRIDGERATOR, UNDER COUNTER VV

U002 GRAB BAR, 1.25" DIA., 42" CC

QH201

F0370

SOFA, SLEEPER,

UPHOLSTERED

F2000

WASTEPAPER

F0400

CABINET, BEDSIDE

M7011

BED

F2420

LAMP, TABLE

F0400

CABINET, BEDSIDE

M3070

HAMPER, LINEN,

MOBILE

F0210

SIDE CHAIR w/o ARMS

BEDROOM

(BSHM1)

BATHROOM

11B

(TSPB1)

CLOSET

11A

(PSCL1)

U002

A5109

GRAB BAR, 1.25" DIA.,

SHOWER

A5205

BAR, TOWEL

P5040

SHOWER, HAND-HELD

A5109

GRAB BAR, 1.25" DIA.,

SHOWER

F2000

WASTEPAPER

A5200

DISPENSER, TOILET

TISSUE

A5170

ROD, SHOWER

CURTAIN

LINEAR DRAIN

A5115

GRAB BAR, FLIP-UP

B

A

AI201

M4802

CHAIR, SHOWER,

BARIATRIC

CB061

CABINET, PERSONAL

ITEMS

M0755

FLOWMETER, OXYGEN

A5048

CABINET, MEDICATION

SECONDARY SHOWER

WAND RECEPTACLE

FD

11A

F3200

CLOCK

M0506

TELEVISION, FLAT

DRESSER / DESK COMBOF0210

SIDE CHAIR w/o ARMS

BUILT-IN LINEN CABINET

RESILIENT BASE

ALIGN

3' - 6"

T1

F0370

SOFA, SLEEPER,

UPHOLSTERED

F2000

WASTEPAPER

RESILIENT BASE

A5048

CABINET, MEDICATION

M3070

HAMPER, LINEN,

MOBILE

F2420

LAMP, TABLE

F0400

CABINET, BEDSIDE

M7011

BED

F0400

CABINET, BEDSIDE

A6046

ARTWORK,

DECORATIVE

NURSE CALL

A1205

LIFT SYSTEM,

OVERHEAD

RESILIENT BASE

11 11B

A1205

LIFT SYSTEM,

OVERHEAD

A5048

CABINET, MEDICATION

RESILIENT BASE

A5145

HOOK, GARMENT

STORAGE

M8

BATH

19A

(TPG01)

SPA

19B

(BTSH1)

QH201

FD

A5205

BAR, TOWEL

F0321

CHAIR, SALON

A5145

HOOK, GARMENT

3'

- 0

M1200

WARMER, BLANKET

M3070

HAMPER, LINEN,

MOBILE

F2015

BASKET, WASTEAPER

19A

A5080

F0321

CHAIR, SALON

A6046

ARTWORK,

DECORATIVE

LIGHTING

2' - 6" 6' - 8 1/2" 3' - 6"

A1085

MIRROR, FLOAT

A5075 A5115

A5200

DISPENSER, TOILET

TISSUE

F2000

WASTEPAPER

LIGHTING

A5080

A5075

2'

0"

S-2

P-1

P-2

RWC-3

RB-1

PT-1

7'

/2

AI502

S1 T1

OPEN TO

BEYOND

A5205

BAR, TOWEL

RESILIENT BASE

GERIATRIC

BATHTUB

NURSE CALL

DEN

(PSDN2)

F0370

SOFA, SLEEPER,

UPHOLSTERED

F2420

LAMP, TABLE

F0740

TABLE, LAMP

F0255

CHAIR, EASY

F2000

WASTEPAPER

F2200

PATIO CHAIR

F0710

TABLE, COMPUTER

M1801

COMPUTER, FLAT

F0280

CHAIR, SWIVEL

ELECTRIC FIREPLACE

2'

1'

" K4665

A5080 R1000

A5075

3'

2' - 6" 2' - 0" 2' - 6"

2' - 5 1/2" 2' - 0" 2' - 6" 2' - 8 3/4"

1'

W1 W1W2

W3

B2B2 B3

JANITOR

(HAC)

P4700

SINK, MOP

A5161

SHELF, UTILITY

SOILED HOLDING

(CSUS3)

A5107

DISPENSER, GLOVES

M3072

FRAME, INFECTIOUS

WAST BAG w/LID

F2020

TRASH CAN, 44 GALLON

M3070

HAMPER, LINEN,

MOBILE

A5075

DISPENSER, SOAP

A5080

DISPENSER, PAPER

TOWEL

P2000

EYE WASH STATION

A5076

DISPENSER, HAND

SANITIZER

P2450

VALVE, MIXING

HOUSEKEEPING

(BSHC1)

M2050

SHELVING, STORAGE,

WIRE

CLEAN LINEN

(STCL1)

M2050

SHELVING, STORAGE,

WIRE

30 QH201

EQUIP. STORAGE

(STMQ2)

WHEELCHAIR

STORAGE

EQUIPMENT GENERAL NOTES

A. PROVIDE BLOCKING IN WALLS TO ACCOMMODATE EQUIPMENT,

FURNISHINGS, TECHNOLOGY AND WALL MOUNTED ACCESSORIES.

B. REFER TO SHEET QH101 FOR EQUIPMENT SCHEDULE.

C. REFER TO SHEET AI601 FOR FINISH SCHEDULE.

D. REFER TO SHEET AI201 FOR TOILET ACCESSORY INFORMATION AND FOR

TOILETS AND SINK LOCATIONS.

E. REFER TO SHEET QH101 FOR EQUIPMENT PLAN.

F. REFER TO SHEET AE200 SERIES FOR ENLARGED TOILET PLANS & INTERIOR

ELEVATION.

G. COORDINATE EQUIPMENT LOCATION, WATER REQUIREMENTS, POWER AND

DATA EQUIPMENTS WITH EQUIPMENT AND ENGINEERING DRAWINGS.

M3070

HAMPER, LINEN,

MOBILE

F2015

BASKET, WASTEAPER

QH201

LAUNDRY

(LAU05)

P6505

SINK, LAUNDRY

M2400

DRYER, ELECTRIC,

FRONT LOAD

M3070

HAMPER, LINEN,

MOBILE

M2300

WASHER, FRONT LOAD

A5080

A5075

A5135

SHELF w/ROD, UTILITY

M2400

DRYER, ELECTRIC,

FRONT LOAD

F2015

BASKET, WASTEAPER

A5080

DISPENSER, PAPER

TOWEL

A5075

DISPENSER, SOAP

P6505

SINK, LAUNDRY

RESILIENT BASE

M2300

WASHER, FRONT LOAD

W1 W1 W1 W1

3' - 0"2' - 0"2' - 0"3' - 0"

10' - 0"

3' - 0" 4' - 0" 3' - 0"

2'

1'

0"

2'

0"

7'

PL-1

PL-1

S-2

PT-3

RB-1

B1 B1B1

F3010

MARKER BOARD, 4'x6'

F3010

MARKER BOARD, 4'x6'

A1030

LOCKER, STAFF

3'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.5

G re e n

H o m e s v d c h ri s te n s e n M

N F

X

.r v t

/1

/2

:4

:0

A

M

QH201

ENLARGED EQUIPMENT PLANS

AND ELEVATIONSGUIDON DESIGN, INC.

1221 N. Pennsylvania Street

Indianapolis, Indiana 46202

317.800.6388

CMTA

10411 Meeting Street

Prospect, Kentucky 40059

502.326.3085

CONSTRUCT TWO NEW GREEN

HOMES 7 & 8

1900 E. MAIN ST., DANVILLE, IL 61832

550-319

7 & 8

04/09/2020 MPJ DMC

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"QH201

1 BEDROOM (11) - BSHM1

SCALE: 1/4" = 1'-0"QH201

3 BEDROOM (11) - SOUTH

SCALE: 1/4" = 1'-0"QH201

4 BEDROOM (11) - EAST

SCALE: 1/4" = 1'-0"QH201

5 BEDROOM (11) - NORTH

SCALE: 1/4" = 1'-0"QH201

2 BEDROOM (11) - WEST

SCALE: 1/4" = 1'-0"QH201

11 SPA (19) - BTSH1

SCALE: 1/4" = 1'-0"QH201

12 SPA (19) & BATH (19B) - SOUTH

SCALE: 1/4" = 1'-0"QH201

13 SPA (19) - EAST

SCALE: 1/4" = 1'-0"QH201

16 DEN (10) - PSDN2

SCALE: 1/4" = 1'-0"QH201

14 STAFF LOUNGE (LGST2) - WEST

SCALE: 1/4" = 1'-0"QH201

10 JANITOR (HAC)

SCALE: 1/4" = 1'-0"QH201

8 SOILED UTILITY (CSUS3)

SCALE: 1/4" = 1'-0"QH201

9 HOUSEKEEPING (BSHC1)

SCALE: 1/4" = 1'-0"QH201

7 CLEAN LINEN

SCALE: 1/4" = 1'-0"QH201

6 EQUIPMENT STORAGE (STMQ2)

SCALE: 1/4" = 1'-0"QH201

17 LAUNDRY (33) - LAU05

SCALE: 1/4" = 1'-0"QH201

18 LAUNDRY (33) - EAST

SCALE: 1/4" = 1'-0"QH201

19 CLEAN LINEN (STLC1) - NORTH

SCALE: 1/4" = 1'-0"QH201

15 STAFF LOUNGE (LGST2) - EAST

OVEN

E

F

DW

QH202

QH202

KITCHEN

(RHKN4)

PANTRY

(CSPY1)

QH202CHARTING

CHARTING

38 5

M2055

SHELVING, STORAGE,

WIRE

R E

F

4'

/2

8B

8A

OPEN TO BEYONDOPEN TO BEYOND

FIREPLACE

F3200

CLOCK

A6046

ARTWORK,

DECORATIVE

OPEN TO BEYOND

OPEN TO BEYOND

A6046

ARTWORK,

DECORATIVE

M0506

TELEVISION, FLAT

F0255

CHAIR, EASY

M0430

DVD PLAYER

A5212

BRACKET, WALL

MOUNTED

FIREPLACE

SOLID SURFACE

SHELF

F3200

CLOCK

INSET WALL

SHELVING

1' - 6"

3 1/4"

6' - 2"

10 3/4"

10 1/4"

SUPPORT BRACKET

4'-0" O.C. MAXRESILIENT BASE

OPEN TO BEYOND

6" 2'

AI502

SHUTTER PASS

THRU DOOR - FLUSH

w/COUNTERTOP

F3200

CLOCK

2' - 0"3' - 7"3' - 0"2"

2' - 0"3' - 6"1' - 9"3/4"

2 1/4"3' - 0"3' - 3"3' - 0"

K4000

HOOD, EXHAUST

K8250

TOASTER

K4502

OVEN, DOUBLE,

RECESSED

2' - 6" 3' - 0" 2' - 9" 2 1/2"

2'

1'

0"

PL-1PL-1

W1W1W1W1W1

B4B4B5B5B4B5

OPEN TO BEYOND

LOCKABLE SNACK

STORAGE CABINET

SWINGING DOOR

w/LATCH

A1015

TELEPHONE, DESK

R4650

DISPENSER, ICE

K4665

MICROWAVE

K1552

COFFEE BREWER, 3

BURNER

F2010

WASTEPAPER,

STEP-ON

R6200

REFRIDGERATOR,

UNDER COUNTER

ALIGN

3' - 0"

2'

0"

1'

0"

2'

/2

2'

1/ 2"

3' - 1 1/2"2' - 9"2' - 4 1/4"

S3P.G S3P.G

S3P.G

AI502 PL-1 PL-1

W1

B1

B1B3

S2

AI502

AI502

R3100

DISHWASHER

TRASH AND

RECYCLING CABINET

SWINGING DOOR

w/LATCH

OPEN TO

BEYOND

3" 2' - 9" 3' - 0"

2'

0"

1'

0"

2'

2 1/4" 3' - 6" 3' - 9"

1' - 5"

1'

/2

PL-1

B5

W1W1

B6

SWINGING DOORS w/LATCH

ALIGN

R4650

DISPENSER, ICE

R3000

REFRIGERATOR,

FRENCH DOOR

A5080

2" 3' - 0" 1 3/4"

1'

0"

2'

1 1/2" 3' - 0" 2' - 3"

SHUTTER PASS THRU

DOORS - FLUSH w/

COUNTERTOP

SH

PL-1

B4

W1W1W3

OFFICE

(OFF02)

F2420

LAMP, TABLE

F0420

CABINET, FILING

F0210

SIDE CHAIR w/o ARMS

E0210

WORKSPACE

w/OVERHEAD CABINET

M1801

COMPUTER, FLAT

A1015

TELEPHONE, DESK M1840

PRINTER/COPIER/FAX

F0275

CHAIR, SWIVEL

F2000

WASTEPAPER

QH202

L

M1840

PRINTER/COPIER/FAX

F2000

WASTEPAPER

M1801

COMPUTER, FLAT

F3200

CLOCK

A1015

TELEPHONE, DESK

SUPPORT BRACKET

4'-0" O.C. MAX

RESILIENT BASE

M1825

PRINTER, WRISTBAND

AI502

E0210

WORKSPACE

w/OVERHEAD CABINET

F2420

LAMP, TABLE

F0420

CABINET, FILING

RESILIENT BASE

F2420

LAMP, TABLE

F0420

CABINET, FILING

A5145

HOOK, GARMENT

L

F0210

SIDE CHAIR w/o ARMS

RESILIENT BASE

EQUIPMENT GENERAL NOTES

A. PROVIDE BLOCKING IN WALLS TO ACCOMMODATE EQUIPMENT,

FURNISHINGS, TECHNOLOGY AND WALL MOUNTED ACCESSORIES.

B. REFER TO SHEET QH101 FOR EQUIPMENT SCHEDULE.

C. REFER TO SHEET AI601 FOR FINISH SCHEDULE.

D. REFER TO SHEET AI201 FOR TOILET ACCESSORY INFORMATION AND FOR

TOILETS AND SINK LOCATIONS.

E. REFER TO SHEET QH101 FOR EQUIPMENT PLAN.

F. REFER TO SHEET AE200 SERIES FOR ENLARGED TOILET PLANS & INTERIOR

ELEVATION.

G. COORDINATE EQUIPMENT LOCATION, WATER REQUIREMENTS, POWER AND

DATA EQUIPMENTS WITH EQUIPMENT AND ENGINEERING DRAWINGS.

7'

"M1801

COMPUTER, FLAT

A5076A5106

SHARPS, w/GLOVES

A5080

F2010

WASTEPAPER,

STEP-ON

A5075

2'

6'

FILLER

1"3' - 0"2' - 6"3' - 0"

FILLER

3/4"

IRWP-2

P-1

PL-1

RB-1

W1 W1 W1

M3150

DISTRIBUTION,

MEDICATION

R6200

REFRIDGERATOR,

UNDER COUNTER

MEDICATION

(CSMR1)

A5075

A5080

F2010

WASTEPAPER,

STEP-ON

A5106

SHARPS, w/GLOVES A5076

QH202

AE501

FD

265 SF

BARIATRIC

(BSHM1)

9 SF

CLOSET

22A

(CASC1)

119 SF

BATHROOM

22B

(TSPB1)

F0210

SIDE CHAIR w/o ARMS

F0370

SOFA, SLEEPER,

UPHOLSTERED

F2000

WASTEPAPER

F0400

CABINET, BEDSIDE

F2420

LAMP, TABLE

F2000

WASTEPAPER

A5200

DISPENSER, TOILET

TISSUE

A5170

ROD, SHOWER

CURTAIN

P5040

SHOWER, HAND-HELD

M4802

CHAIR, SHOWER,

BARIATRIC

A5205

BAR, TOWEL

F0400

CABINET, BEDSIDE

M7012

BARIATRIC BED

U002

GRAB BAR, 1.25" DIA.,

42"

A5110

GRAB BAR, SHOWER

LINEAR DRAIN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.5

G re e n

H o m e s v d c h ri s te n s e n M

N F

X

.r v t

/1

/2

:4

:1

A

M

QH202

ENLARGED EQUIPMENT PLANS

AND ELEVATIONSGUIDON DESIGN, INC.

1221 N. Pennsylvania Street

Indianapolis, Indiana 46202

317.800.6388

CMTA

10411 Meeting Street

Prospect, Kentucky 40059

502.326.3085

CONSTRUCT TWO NEW GREEN

HOMES 7 & 8

1900 E. MAIN ST., DANVILLE, IL 61832

550-319

7 & 8

04/09/2020 MPJ DMC

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/4" = 1'-0"QH202

6 KITCHEN (8) - RHKN4

SCALE: 1/4" = 1'-0"QH202

12 DINING ROOM (7) - SOUTH

SCALE: 1/4" = 1'-0"QH202

13 LIVING ROOM (6) - NORTH

SCALE: 1/4" = 1'-0"QH202

7 KITCHEN (8) - NORTH EXTERIOR

SCALE: 1/4" = 1'-0"QH202

11 KITCHEN (8) - NORTH

SCALE: 1/4" = 1'-0"QH202

9 KITCHEN (8) - SOUTH

SCALE: 1/4" = 1'-0"QH202

10 KITCHEN (8) - EAST

SCALE: 1/4" = 1'-0"QH202

8 KITCHEN (8) - WEST

SCALE: 1/4" = 1'-0"QH202

1 OFFICE (34) - OFF02

SCALE: 1/4" = 1'-0"QH202

2 OFFICE (34) - SOUTH

SCALE: 1/4" = 1'-0"QH202

3 OFFICE (34) - WEST

SCALE: 1/4" = 1'-0"QH202

4 OFFICE (34) - NORTH

SCALE: 1/4" = 1'-0"QH202

5 TYPICAL CHARTING STATION

SCALE: 3/8" = 1'-0"QH202

15 MEDICATION (CSMR1) - NORTH

SCALE: 1/4" = 1'-0"QH202

14 MEDICATION (CSMR1)

SCALE: 1/4" = 1'-0"QH202

16 BARIATRIC BEDROOM

F

OVEN

R E

F

DW

DN

AA.2

B B.2 D E F G H J

C

2.5

C.6

9.6

C.7C.5

7.1

9.1

H.6E.5D.5

HATCHED AREA INDICATES AREA TO BE PROVIDED WITH A FULLY AUTOMATIC WET

SPRINKLER SYSTEM. ALL SPRINKLER RELATED WORK SHALL BE DONE IN

ACCORDANCE WITH NFPA 13 AND ALL STATE AND LOCAL CODES.

ORDINARY HAZARD,

GROUP 1

LIGHT HAZARD

I LL IN O IS

R

.E

SS

E J

FARBE

LICENSED

PROFESSIONAL

OF

ENGINEER

062.069980

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C U s e rs

\I R a p p \D o c u m e n ts \V

IG

H

-M -R ir a p p

X

W

.r v t

/1

/2

:0

:0

A

M

FP101

FIRE PROTECTION PLAN

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA ST.

SUITE 200

317.800.6388

CMTA

10411 Meeting Street

Prospect, Kentucky 40059

502.326.3085

CONSTRUCT TWO NEW GREEN

HOMES 7 & 8

1900 E. MAIN ST., DANVILLE, IL 61832

550-319

7 & 8

04/09/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

1/8" = 1'-0"

FIRST FLOOR PLAN - FIRE PROTECTION

FIRE PROTECTION GENERAL NOTES:

GENERAL NOTES -FIRE PROTECTION

A. ALL AREAS SHALL BE PROTECTED BY A 100% WET PIPE FIRE SUPPRESSION

SYSTEM INSTALLED IN STRICT ACCORDANCE WITH NFPA-13, THE STATE

BUILDING CODES AND THE PROJECT SPECIFICATIONS.

B. ALL AREAS ARE PRESENTLY PROTECTED BY A 100% WET PIPE FIRE

SUPPRESSION SYSTEM. CONTRACTOR SHALL MODIFY THE SYSTEM AS

REQUIRED TO MAINTAIN 100% PROTECTION, IN ACCORDANCE WITH NFPA 13,

STATE BUILDING CODE AND SPECIFICATIONS.

C. THE SUCCESSFUL FIRE PROTECTION CONTRACTOR SHALL OBTAIN AND

UTILIZE THE ARCHITECTURAL REFLECTED CEILING PLAN FOR LAYING OUT

THE SPRINKLER HEADS. THE REFLECTED CEILING PLANS SHOWN ARE TO

COORDINATE CEILING TYPES AND LOCATIONS. REFER TO THE MECHANICAL

AND ELECTRICAL DRAWINGS FOR CEILING DEVICE LOCATIONS. REFER TO

THE SPECIFICATIONS FOR COORDINATION DRAWING REQUIREMENTS.

D. INSTALL HEADS IN CENTER OF 2'X2' TILES. INSTALL HEADS ON 1/4 POINTS

OF THE 4' DIMENSION AND CENTER OF THE 2' DIMENSION IN 2'X4' TILES.

DO NOT MOUNT HEADS IN CENTER OF 2'X4' TILE IF IT IS SCORED TO LOOK

LIKE TWO 2'X2' TILES.

E. ALL SPRINKLER HEADS SHALL BE "SEMI-RECESSED", QUICK RESPONSE

SPRINKLER HEADS (UNLESS OTHERWISE NOTED ON THE PLANS.) HEADS

SHALL BE FED FROM A RETURN BEND ARRANGEMENT.

F. UTILIZE UPRIGHT AND/OR WALL-MOUNTED TYPE SPRINKLER HEADS IN

AREAS WITHOUT CEILINGS.

G. THE FIRE PROTECTION CONTRACTOR SHALL PERFORM HIS OWN FLOW

TEST

PRIOR TO SUBMITTING SHOP DRAWINGS.

H. REFER TO A COMPLETE SET OF DOCUMENTS (ARCHITECTURAL,

STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICAITONS)

FOR COORDINATION OF TRADES, ROOMS, STRUCTURE AND EQUIPMENT.

HVAC DUCTWORK MAINS SHALL BE INSTALLED PRIOR TO FIRE PROTECTION

PIPING. PROVIDE DRAIN VALVES IN THE FIRE PROTECTION SYSTEM WHERE

REQUIRED TO COMPLETELY DRAIN THE SYSTEM.

I. REFER TO THE SPECIFICATIONS FOR SPRINKLER HEAD TYPES.

J. PROVIDE ALL REQUIRED DRAIN PIPING TO TEST FLOW SWITCHES.

DISCHARGE DRAIN PIPING TO OUTDOORS OR A FLOOR DRAIN.

K. SIZE ALL FIRE PROTECTION PIPING IN ACCORDANCE WITH NFPA 13. PIPE

SIZING SHALL BE ACCOMPLISHED USING HYDRAULIC CALCULATIONS.

L. SUBMIT HYDRAULIC CALCULATIONS AND SYSTEMS DESIGN FOR REVIEW TO

THE M/E ENGINEER.

M. THE CONTRACTOR SHALL EXERCISE EXTREME CARE IN THE COURSE OF

THEIR WORK SO AS TO ENSURE THAT THEY DO NOT INTERRUPT ANY

EXISTING SERVICE. FOR SAFETY PURPOSES, PAY PARTICULAR ATTENTION

TO THIS PRECAUTION RELATIVE TO NATURAL GAS AND ELECTRICAL LINES.

VERIFY THE LOCATION, SIZE, TYPE, ETC., OF EACH UNDERGROUND OR

OVERHEAD UTILITY. ALL WORK SHALL BE PERFORMED IN ACCORD WITH

ALL FEDERAL, STATE AND/OR LOCAL RULES, REGULATIONS, STANDARD AND

SAFETY REQUIREMENTS.

N. WHERE WORK IS REQUIRED ABOVE EXISTING LAY-IN, PLASTER OR

GYPSUM BOARD CEILINGS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR

REMOVAL AND REINSTALLATION (OR REPLACEMENT, IF DAMAGED) OF ALL

CEILING OR TILE AND GRID MEMBERS NECESSARY TO PERFORM HIS WORK.

NEW TILE AND GRID SHALL MATCH THE SURROUNDING AREAS. ALL

PATCHING WORK SHALL MATCH ADJACENT SURFACES.

O. ALL NEW WORK SHALL BE HUNG FROM STRUCTURE, NOT FROM THE

WORK OF OTHER TRADES, WHETHER EXISTING OR NEW.

P. COORDINATE ALL WORK WITH PROJECT PHASING REQUIREMENTS.

Q. PATCH, REPAIR AND PAINT OR PROVIDE WALL COVERING FOR (TO

OWNER'S STANDARDS) EXISTING WALLS, CEILINGS, ETC., THAT ARE TO

REMAIN IF

DAMAGED DURING CONSTRUCTION. REPAIRS SHALL MATCH ADJACENT

SURFACES TO THE SATISFACTION OF THE ARCHITECT AND OWNER.

R. OBSERVE ALL APPLICABLE CODES, RULES AND REGULATIONS THAT MAY

APPLY TO THE WORK UNDER THIS CONTRACT. (CITY, COUNTY, LOCAL,

FEDERAL, MUNICIPALITY, UTILITY COMPANY, STATE, ETC.)

S. CONTRACTOR SHALL BE AWARE OF UNSEEN PLUMBING, HVAC AND

ELECTRICAL WORK DURING DEMOLITION. IF ITEMS ARE UNCOVERED

DURING DEMOLITION THEN FIELD VERIFY THE USE OF THE ITEMS AND PLAN

AN ALTERNATE ROUTE TO RUN THESE ITEMS. THEN CONTACT THE

ENGINEERS TO REVIEW THE ROUTING.

T. ALL PENETRATIONS OF FIRE AND SMOKE RATED ASSEMBLIES SHALL BE

APPROPRIATELY FIRE STOPPED PER AN APPROVED U.L. LISTED STANDARD.

CONTRACTOR SHALL PAY PARTICULAR ATTENTION TO INSULATED PIPING

PENETRATIONS.

U. ALL WORK REQUIRING DOWNTIME OF ANY AREA IN THE BUILDING SHALL

BE SCHEDULED 2 WEEKS IN ADVANCE, AND SHALL COMPLY WITH INTERIM

LIFE SAFETY MEASURES.

V. WHERE CEILINGS ARE INDICATED ALL SPRINKLER PIPING MUST BE

INSTALLED ABOVE CEILINGS. SPRINKLER PIPING MUST BE COORDINATED

WITH OTHER TRADES. PIPING MUST BE OFFSET TO AVOID CONFLICTS WITH

DUCTWORK, CONDUIT, ALL EQUIPMENT, ETC.

W. LOCATIONS OF PIPING, DUCTS AND EQUIPMENT ARE APPROXIMATE AND

SUBJECT TO MINOR ADJUSTMENTS IN THE FIELD. DO NOT SCALE THE

DRAWINGS.

X. ALL OFFSETS IN DUCTS AND PIPING ARE NOT NECESSARILY SHOWN.

PROVIDE ADDITIONAL OFFSETS WHERE NECESSARY.

Y. COORDINATE ALL HVAC WORK WITH ELECTRICAL, PLUMBING AND OTHER

TRADES TO AVOID INTERFERENCE WITH PIPING, DUCTS, CONDUIT AND

OTHER EQUIPMENT.

Z. SEAL AIRTIGHT AROUND ALL DUCTS AND PIPING PENETRATIONS THROUGH

WALLS, FLOORS AND ROOF. PROVIDE FIRE STOPPING IN FIRE PARTITION.

AA. THE CONTRACTOR SHALL RELOCATE OR AVOID ANY EXISTING

EQUIPMENT APPURTENANCES, ETC., THAT CONFLICT WITH NEW WORK.

BB. VALVES, BALANCING DAMPERS OR ANY MECHANICAL/ELECTRICAL ITEM

REQUIRING ACCESS SHALL NOT BE LOCATED ABOVE A HARD CEILING. IF

THIS IS NOT POSSIBLE, THEN AN APPROPRIATELY SIZED ACCESS DOOR

SHALL BE PLACED UNDER THE ITEM TO ALLOW EASY MAINTENANCE AND

ADJUSTMENT. ADDITIONALLY ALL SUCH ITEMS SHALL NOT BE LOCATED AN

UNREASONABLE DISTANCE ABOVE THE CEILINGS. IN GENERAL ALL SUCH

ITEMS UNLESS INDICATED OTHERWISE SHALL BE MOUNTED SIX TO TWELVE

INCHES ABOVE THE CEILING. IF IN DOUBT, CONTACT ENGINEER PRIOR TO

INSTALLING.

2-HOUR RATING

G

CA

FP

ORL

RL

GW

FM

SAN

SS

VT

E(NAME)

ABAN(NAME)

O

A

V

FD-#

RD-#

P-#

TS

FS

PS

BALANCING VALVE

BALL VALVE

CHECK VALVE

FLOW SWITCH

PRESSURE SWTICH

TAMPER SWITCH

THERMOMETER

DOUBLE CHECK VALVE ASSEMBLY

PIPING UNION

COMPRESSED AIR

FIRE PROTECTION LINE

SANITARY WASTE PIPING TO GREASE TRAP

OVERFLOW ROOF LEADER PIPING

ROOF LEADER PIPING

FORCED MAIN

GAS LINE

PETE'S PLUG

POINT OF CONNECTION

LIMIT OF DEMOLITION

OS&Y (GATE) VALVE

PIPE ELBOW TURNING UP/TURNING DOWN

PIPE TEE TURNING UP/TURNING DOWN

MEDICAL AIR

ABOVE FINISHED FLOOR

ABOVE FINISHED ROOFAFR

AFF

A, AIR

CARBON DIOXIDECO2

DOMESTIC COLD WATERCW

EVACUATION (WASTE ANESTHETIC GAS DISPOSAL)EV

FIRE HOSE VALVE WITH CABINETFHV

FREEZE PROOF WALL HYDRANTFPWH

HOSE BIBBHB

DOMESTIC HOT WATERHW

INSIDE DIMENSIONID

IN ACCORDANCE WITHIAW

INVERT ELEVATIONIE

LINE PRESSURE ALARM (MEDICAL GAS AREA ALARM)LPA

MANHOLEMH

MULTI-SINGLE ALARM (MEDICAL GAS MASTER ALARM)MSA

NOT TO SCALENTS

NOT IN CONTRACTNIC

NORMALLY OPENNO

NORMALLY CLOSEDNC

OXYGENO, OX

OUTSIDE DIMENSIONOD

OPEN RECEPTACLEOR

TOP ELEVATIONTE

TYPICALTYP

UNLESS OTHERWISE NOTEDUON

SANITARY WASTE PIPING

STORM SEWER PIPING

VENT PIPING

EXISTING PIPING (THIN LINE)

ABANDONED EXISTING PIPING (THIN LINE)

DOMESTIC COLD WATER PIPING

DOMESTIC HOT WATER SUPPLY

DOMESTIC RECIRCULATING HOT WATER

CLEANOUT IN CEILING SPACE

FLOOR CLEANOUT

EXTERIOR CLEANOUT

SYMBOLS & ABBREVIATIONS

CAST IRONC.I.

DOWNDN

OVERFLOW ROOF LEADERORL

PRESSURE REDUCING VALVE (STEAM, WATER, OR GAS)PRV

POUNDS PER SQUARE INCHPSI

DOMESTIC RECIRCULATING HOT WATERRHW

ROOF LEADERRL

SOFT DOMESTIC COLD WATERSCW

SANITARY RISERSR

THRUST BLOCKTB

TRAP PRIMERTP

VACUUMV, VAC

VENT THRU ROOFVTR

OWNER FURNISHED, CONTRACTOR INSTALLEDOFCI

OWNER FURNISHED, OWNER INSTALLEDOFOI

CONTRACTOR FURNISHED, CONTRACTOR INSTALLEDCFCI

CO

CO

ECO

OXYGEN PIPING

MEDICAL AIR

VACUUM PIPING

FLOOR DRAIN DESIGNATOR

ROOF DRAIN DESIGNATOR

PLUMBING FIXTURE DESIGNATOR

XXX

X

EQUIPMENT TAG DESIGNATOR

PRESSURE REDUCING VALVE (STEAM, GAS, WATER, ETC.)

STRAINER

X TAGGED NOTE DESIGNATOR

X REVISION DESIGNATOR

SAFETY RELIEF VALVE

SAFETY RELIEF VALVE

LIMITED AREA SPRINKLER HEAD

VACUUM BREAKERV

T S

TEMPERATURE SENSOR

HOSE BIB

I LL IN O IS

R

.E

SS

E J

FARBE

LICENSED

PROFESSIONAL

OF

ENGINEER

062.069980

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C U s e rs

\I R a p p \D o c u m e n ts \V

IG

H

-M -R ir a p p

X

W

.r v t

/1

/2

:0

:0

A

M

PL000

PLUMBING LEGEND

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA ST.

SUITE 200

317.800.6388

CMTA

10411 Meeting Street

Prospect, Kentucky 40059

502.326.3085

CONSTRUCT TWO NEW GREEN

HOMES 7 & 8

1900 E. MAIN ST., DANVILLE, IL 61832

550-319

7 & 8

04/09/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

PLUMBING GENERAL NOTES:

A. COORDINATE THE LOCATION OF DRAINS, THERMOSTATS, GAS

OUTLETS, ETC., WITH ALL CASEWORK EQUIPMENT,

MECHANICAL ROOM EQUIPMENT, ETC., PRIOR TO COMMENCING

INSTALLATION. WORK NOT SO COORDINATED SHALL BE

REMOVED AND PROPERLY INSTALLED AT THE EXPENSE OF THE

CONTRACTOR.

B. THE CONTRACTOR SHALL EXERCISE EXTREME CARE IN THE

COURSE OF THEIR WORK SO AS TO INSURE THAT THEY DO NOT

INTERRUPT ANY EXISTING SERVICE. FOR SAFETY PURPOSES,

PAY PARTICULAR ATTENTION TO THIS PRECAUTION RELATIVE

TO NATURAL GAS AND ELECTRICAL LINES. VERIFY THE

LOCATION, SIZE, TYPE, ETC., OF EACH UNDERGROUND OR

OVERHEAD UTILITY. ALL WORK SHALL BE PERFORMED IN

ACCORD WITH ALL FEDERAL, STATE AND/OR LOCAL RULES,

REGULATIONS, STANDARD AND SAFETY REQUIREMENTS.

UTILITIES SHALL BE INSTALLED IN ACCORD WITH THE

APPLICABLE MUNICIPALITY OR UTILITY COMPANY STANDARDS.

IN ALL CASES, THE MOST STRINGENT REQUIREMENT SHALL

APPLY.

C. WHERE WORK IS REQUIRED ABOVE EXISTING LAY-IN, PLASTER

OR GYPSUM BOARD CEILINGS, THE CONTRACTOR SHALL BE

RESPONSIBLE FOR REMOVAL AND REINSTALLATION (OR

REPLACEMENT, IF DAMAGED) OF ALL CEILING OR TILE AND

GRID MEMBERS NECESSARY TO PERFORM HIS WORK. NEW

TILE AND GRID SHALL MATCH THE SURROUNDING AREAS. ALL

PATCHING WORK SHALL MATCH ADJACENT SURFACES.

D. ALL NEW WORK SHALL BE HUNG FROM STRUCTURE, NOT FROM

THE WORK OF OTHER TRADES, WHETHER EXISTING OR NEW.

E. COORDINATE ALL WORK WITH PROJECT PHASING

REQUIREMENTS.

F. PATCH, REPAIR AND PAINT OR PROVIDE WALL COVERING FOR

(TO OWNER'S STANDARDS) EXISTING WALLS, CEILINGS, ETC.,

THAT ARE TO REMAIN IF DAMAGED DURING CONSTRUCTION.

REPAIRS SHALL MATCH ADJACENT SURFACES TO THE

SATISFACTION OF THE ARCHITECT AND OWNER.

G. OBSERVE ALL APPLICABLE CODES, RULES AND REGULATIONS

THAT MAY APPLY TO THE WORK UNDER THIS CONTRACT.

(CITY, COUNTY, LOCAL, FEDERAL, MUNICIPALITY, UTILITY

COMPANY, COMMONWEALTH OF KENTUCKY, ETC.)

H. CONTRACTOR SHALL BE AWARE OF UNSEEN PLUMBING WORK

DURING DEMOLITION. IF ITEMS ARE UNCOVERED DURING

DEMOLITION THEN FIELD VERIFY THE USE OF THE ITEMS AND

PLAN AN ALTERNATE ROUTE TO RUN THESE ITEMS. THEN

CONTACT THE ENGINEERS TO REVIEW THE ROUTING.

I. IF AREA OF CONSTRUCTION HAS A POST TENSION FLOOR SLAB.

CONTRACTOR SHALL USE ULTRA SOUND OR OTHER APPROVED

METHODS TO SURVEY THE EXISTING FLOOR STRUCTURE

BEFORE MAKING ANY AND ALL FLOOR PENETRATIONS.

J. WHERE FIRE PROOFING IS SPRAYED ON EXISTING STRUCTURE

ALL EXISTING CONDUITS, WATER, HYDRONIC, STEAM, CHILLED

WATER, FIRE PROTECTION LINES, MED GAS, ETC. SHALL BE

LOWERED TO BE BELOW FULL THICKNESS OF FIRE PROOFING

WITH NO INTERFERENCE.

K. ALL PENETRATIONS OF FIRE AND SMOKE RATED ASSEMBLIES

SHALL BE APPROPRIATELY FIRE STOPPED PER AN APPROVED

U.L. LISTED STANDARD. CONTRACTOR SHALL PAY PARTICULAR

ATTENTION TO INSULATED PIPING PENETRATIONS.

L. ALL WORK REQUIRING DOWNTIME OF ANY AREA IN THE

BUILDING SHALL BE SCHEDULED 2 WEEKS IN ADVANCE, AND

SHALL COMPLY WITH INTERIM LIFE SAFETY MEASURES.

M. ALL PIPING IN ROOMS WITH CEILINGS SHALL BE ABOVE CEILING

EXCEPT AS NOTED.

N. LOCATIONS OF PIPING AND EQUIPMENT ARE APPROXIMATE AND

SUBJECT TO MINOR ADJUSTMENTS IN THE FIELD. DO NOT

SCALE THE DRAWINGS.

O. ALL OFFSETS IN PIPING ARE NOT NECESSARILY SHOWN.

PROVIDE ADDITIONAL OFFSETS WHERE NECESSARY.

P. THE CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY COMPANY

FEES OR OTHER COSTS THAT ANY UTILITY COMPANY MAY

REQUIRE TO COMPLETE THEIR WORK. (GAS, SEWER, WATER,

ETC.).

Q. WHERE MOUNTING HEIGHTS ARE NOT INDICATED OR ARE IN

CONFLICT WITH ANY OTHER BUILDING SYSTEM, CONTACT THE

ENGINEERS BEFORE INSTALLATION. REFER ALSO TO

ARCHITECTURAL WALL INTERIOR AND EXTERIOR WALL

ELEVATIONS, CEILING HEIGHTS AND OTHER DETAIL OF THESE

DOCUMENTS.

R. ANY VIBRATING, OSCILLATING OR OTHER NOISE OR MOTION

PRODUCING EQUIPMENT SHALL BE ISOLATED FROM

SURROUNDING SYSTEMS IN AN APPROVED MANNER. NOISY OR

STRUCTURALLY DAMAGING INSTALLATIONS SHALL BE

SATISFACTORILY REPLACED OR REPAIRED AT THE INSTALLING

CONTRACTOR'S EXPENSE. THE FINAL DECISION ON THE

SUITABILITY OF A PARTICULAR INSTALLATION'S ACCEPTABILITY

SHALL BE THAT OF THE ENGINEER.

S. DEVIATIONS IN SIZE, CAPACITIES, FIT, FINISH, ETC. FOR

EQUIPMENT FROM THAT USED AS BASIS OF DESIGN SHALL BE

THE RESPONSIBILITY OF THE PURCHASER OF THAT

EQUIPMENT. ANY PROVISIONS REQUIRED TO ACCOMMODATE A

DEVIATION, WHETHER APPROVED BY THE ENGINEERS OR NOT,

SHALL BE THE RESPONSIBILITY OF THE PURCHASER.

T. VALVES, BALANCING DAMPERS OR ANY

MECHANICAL/ELECTRICAL ITEM REQUIRING ACCESS SHALL NOT

BE LOCATED ABOVE A HARD CEILING. IF THIS IS NOT POSSIBLE,

THEN AN APPROPRIATELY SIZED ACCESS DOOR SHALL BE

PLACED UNDER THE ITEM TO ALLOW EASY MAINTENANCE AND

ADJUSTMENT. ADDITIONALLY ALL SUCH ITEMS SHALL NOT BE

LOCATED AN UNREASONABLE DISTANCE ABOVE THE CEILINGS.

IN GENERAL ALL SUCH ITEMS UNLESS INDICATED OTHERWISE

SHALL BE MOUNTED SIX TO TWELVE INCHES ABOVE THE

CEILING. IF IN DOUBT, CONTACT ENGINEER PRIOR TO

INSTALLING.

U. ALL MANHOLES, VAULTS AND SIMILAR UNDERGROUND

STRUCTURES SHALL HAVE THE TOP ELEVATION SET FLUSH

WITH FINISHED GRADE UNLESS SPECIFICALLY NOTED

OTHERWISE.

V. WHEN RUNNING ANY TYPE OF PIPING BELOW A FOOTER, OR IN

THE ZONE OF INFLUENCE THE PIPING SHALL BE BACKFILLED

WITH CEMENTITIOUS FLOWABLE FILL PER SPECIFICATIONS.

WHENEVER POSSIBLE, LOCATE PIPING OUTSIDE OF THE ZONE

OF INFLUENCE. THE ZONE OF INFLUENCE IS THE AREA UNDER

THE FOOTER WITHIN A 45 DEGREE ANGLE PROJECTING DOWN

FROM THE BOTTOM EDGE OF THE FOOTER OF ALL SIDES OF

THE FOOTER. ADDITIONALLY, GREASE TRAPS, MANHOLES,

VAULTS AND OTHER UNDERGROUND STRUCTURES SHALL BE

HELD AWAY FROM BUILDING WALLS FAR ENOUGH TO BE

OUTSIDE OF THE ZONE OF INFLUENCE.

W. WORK IN CONFINED AREAS SHALL BE IN ACCORDANCE WITH

THE OWNER'S SAFETY POLICY REQUIREMENTS.

TMV

PLUMBING FIXTURE SCHEDULE

TAG FIXTURE CW HW VENT WASTE

FD-B SHOWER - - 1-1/2 3

GT-1 GREASE TRAP - - - 3

P-101 FLOOR SET FLUSH VALVE WATER CLOSET 1 - 2 4

P-301 BATHTUB 3/4 3/4 1-1/2 2

P-400 WALL HUNG HAND SINK 1/2 1/2 1-1/2 2

P-401 WALL HUNG HAND SINK 1/2 1/2 1-1/2 2

P-402 SALON SINK 1/2 1/2 1-1/2 2

P-413 LAVATORY 1/2 1/2 1-1/2 2

P-501 MOP SINK 3/4 3/4 1-1/2 3

P-503 KITCHEN SINK 1/2 1/2 1-1/2 2

P-528 DROP IN HAND SINK 1/2 1/2 1-1/2 2

P-701 SHOWER - - 1-1/2 3

P-708 EMERGENCY EYE WASH 1/2 1/2 1-1/2 2

P-801 FREEZE PROOF WALL HYDRANT 1/2 - - -

P-802 FLOOR SINK - - 2 4

P-812 OUTLET BOX 1/2 1/2 1-1/2 3

RD ROOF DRAIN - - - -

GAS FIRED WATER HEATER SCHEDULE

MARK VOLUME GAS INPUT BASIS OF DESIGN ALTERNATE MANUFACTURERS

WH-1 100 GAL 150,000 BTU AO SMITH BTH-150 LOCHINVAR, RHEEM

WATER HEATER IN BOTH BUILDINGS.

F

R E

F

DW

DN

AA.2

B B.2 D E F G H J

C

2.5

C.6

9.6

C.7C.5

7.1

9.1

H.6E.5D.5

CO

CO

CO CO

CO

GT-1

S A

N

4" SAN

S A

N

G W

S A

N

G W

S A

N

2" G

1 1/2" CW

S A

N

2" SAN

FPWH

FPWH

P-101 P-101 P-101

P-101

P-101

P-101

P-101

P-101

P-101

P-101

P-701

P-401

P-101P-101

P-708

P-101

P-701

P-701

P-701

P-701

P-701

P-701

P-701

P-701

P-413

P-413

P-413

P-413

P-402

P-301

P-413

P-413 P-413

P-413

P-413

P-400

P-413

P-413

P-528

P-413P-413

P-528

P-528

P-802

2" VT

3" GW

P-501

P1

P1

P1

P2

P3

GARAGE

STORAGE

SCREENED PORCH

LIVING ROOM

PATIO

DINING

PATIO

CORRIDOR

KITCHEN

DEN

PANTRY

CORRIDOR

BEDROOM

BATHROOM

23B

BATHROOM

22B

BARIATRIC

BEDROOM

BATHROOM

21B

BEDROOM

BATHROOM

20B

BATH

19A

SPA

19B

CORRIDOR

VESTIBULE

BEDROOM

BEDROOM

BATH

17B

CORRIDOR

MECHANICAL CLOSET

M12

HOUSEKEEPING

EQUIP. STORAGE

CLEAN LINEN

LAUNDRY

OFFICE

MEDICATION

BATH

16B

VESTIBULE

CORRIDOR

BEDROOM

BATHROOM

14B

BATHROOM

13B

BEDROOM

BEDROOM

BATHROOM

12B

BATHROOM

11B

BEDROOM

CORRIDOR

P7

P-701

R W

L

FD-B (TYP

IN P701)

P8

I LL IN O IS

R

.E

SS

E J

FARBE

LICENSED

PROFESSIONAL

OF

ENGINEER

062.069980

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C U s e rs

\I R a p p \D o c u m e n ts \V

IG

H

-M -R ir a p p

X

W

.r v t

/1

/2

:0

:1

A

M

PL100

PLUMBING UNDERGROUND PLAN

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA ST.

SUITE 200

317.800.6388

CMTA

10411 Meeting Street

Prospect, Kentucky 40059

502.326.3085

CONSTRUCT TWO NEW GREEN

HOMES 7 & 8

1900 E. MAIN ST., DANVILLE, IL 61832

550-319

7 & 8

04/09/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

1/8" = 1'-0"

UNDERGROUND PLAN - PLUMBING

TAGGED NOTES

P1 REFER TO CIVIL DRAWINGS FOR CONTINUATION.

P2 UNDERSLAB VENT FOR FLOOR SINK.

P3 VENT UP IN WALL.

P7 GREASE TRAP SHALL BE STAINLESS STEEL, 30 GPM MODEL

JAY R SMITH 8015.

P8 DISHWASHER TO DRAIN TO FLOOR SINK.

F

OVEN

R E

F

DW

DN

AA.2

B B.2 D E F G H J

C

2.5

C.6

9.6

C.7C.5

7.1

9.1

H.6E.5D.5

PL101

V T

/2

H W

/2

C W

/2

C W

H W

V T

1 1/2" CW

1" HW

/2

H W

2" VT2" VT

FPWH

SCREENED PORCH

3/4" CW

FPWH

3/4" CW

P-413

P-413

P-413

P-413

P-413

P-413

P-413

P-413P-413

P-528

P-413P-413

P-528

P-413P-301 P-101

P-101 P-101

P-101

P-101

P-101

P-101

P-101

P-101

P-101

P-402

P-528

P-701

P-801

P-503

P-401

P-101P-101

P-708

P-413 P-101

1/2" CW

3/4" HW

1 1/2" VT

P-400

P-501

/2

C W

FPWH

/4

H

W R

/4

C

W R

/4

C

W R

/4

H

W R

/4

H

W R

/4

C

W R

/2

C W

H W

P-701 P-701P-701

P-701

P-701

P-701

P-701

P-701

P5

1/2" CWR

1/2" CWR

1/2" CWR

1/2" CWR

SPA

19B

VESTIBULE

BEDROOM

BEDROOM

BATH

16B

BATH

17B

VESTIBULE

CORRIDOR

LAUNDRY

MECHANICAL CLOSET

M12

EQUIP. STORAGE

31HOUSEKEEPING

32 CLEAN LINEN

CORRIDOR / STORM SHELTER

MEDICATION

BATHROOM

13B

BATHROOM

14B

BEDROOM

BEDROOM

BEDROOM

BATHROOM

12B

BEDROOM

BATHROOM

11B

DEN

GARDEN STORAGE

PATIO

DINING

LIVING ROOM

STORAGE

GARAGE

CORRIDOR

BEDROOM

BATHROOM

23B

BATHROOM

22B

BARIATRIC

BEDROOM

BATHROOM

21B

BEDROOM

BATHROOM

20B

P6

R W

L

3/4" CW

4" SAN

P-701

P-812

D E

C.6

9.6

D.5

1 1/2" CW

BFP

WH-1

CP

/2

C W

/2

H W

CP

/4

C

W R

/4

H

W R

P4

FD-B

FD-B

VENT UP

VENT UP

G

2" G

/2

G

I LL IN O IS

R

.E

SS

E J

FARBE

LICENSED

PROFESSIONAL

OF

ENGINEER

062.069980

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C U s e rs

\I R a p p \D o c u m e n ts \V

IG

H

-M -R ir a p p

X

W

.r v t

/1

/2

:0

:1

A

M

PL101

PLUMBING FIRST FLOOR PLAN

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA ST.

SUITE 200

317.800.6388

CMTA

10411 Meeting Street

Prospect, Kentucky 40059

502.326.3085

CONSTRUCT TWO NEW GREEN

HOMES 7 & 8

1900 E. MAIN ST., DANVILLE, IL 61832

550-319

7 & 8

04/09/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

1/8" = 1'-0"

FIRST FLOOR PLAN - PLUMBING

1/4" = 1'-0"

MEZZANINE - PLUMBING

TAGGED NOTES

P4 DOMESTIC COLD WATER RETURN TO TERMINATE WITH CHECK

VALVE INTO WATER SERVICE AFTER CONNECTION TO

BACKFLOW PREVENTER.

P5 CWR AND HWR PIPING BACK IN WALLS TO RETURN MAINS.

SHOWN OUT OF WALLS FOR CLARITY. (TYP)

P6 SHUTOFF VALVES FOR DOMESTIC PIPING IN CORRIDOR

BEFORE ENTERING BATHROOM. (TYP)

ALL SINKS AND SHOWERS SHALL HAVE THERMOSTATIC MIXING VALVES.

RWL UP

TO RD

BALANCING

VALVE FOR

RHW (TYP)

4" S

AN

3" G W

4" SAN

CO

CO

CO

CO

CO

CO

4" SAN

4" SAN

2" SAN

2" VT

2" VT

2" VT

1 1/2" VT

1 1/2" VT

2" VT

2" VT2" VT

2" VT

4" SAN

2" SAN

2" VT

2" VT

4" SAN

2" SAN

3" SAN

2" SAN

3" GW

2" SAN

2" VT

4" SAN

4" SAN

4" SAN

4" SAN

2" SAN

4" SAN

2" VT

1 1/2" VT

2" VT

2" VT

2" VT

2" SAN

P-101

P-528

P-101

P-101

P-101

P-101

P-101

P-101

P-101

P-101

P-413

P-413

P-413 P-528

P-528

P-413

P-413

P-413

P-413

P-413

P-402

P-413

P-413

P-101

P-413

P-413

P-301

P-101

P-101

P-503

P-401 P-708

P-413

P-101

1 1/2" VT

P-501

P-400

2" SAN

2" VT

2" SAN

4" SAN

P-802

4" SAN

/2

V T

V T

2" SAN

4" SAN

2" VT

2" VT 1 1/2" VT

1 1/2" VT

2" VT

2" VT

2" VT1 1/2" VT

1 1/2" VT

2" SAN

2" SAN

/2

V T

2" SAN

4" SAN

2" SAN

P-701

FD-B

FD-B

FD-B

FD-B

FD-B

FD-B

FD-B

FD-B

FD-B

FD-B

S A

N

V

T

V T

FD-B

FD-B

GT-1

1 1/2" H W

1" HW

1 1/2" CW

1 1/2" CW 1" HW

1 1/2" CW

3/4" CW

3/4" HW

1 1/2" HW

1 1/2" CW

1 1/2" CW

3/4" HW

3/4" HW

1 1/2" CW

3/4" HW

1/2" CW

1 1/2" HW

1 1/2" CW

1 1/2" CW

1" HW

1 1/2" CW

3/4" HW

1/2" CW

1" HW

1/2" CW

3/4" CW

3/4" CW

1/2" CW

3/4" HW

/2

C W

3/4" CW

R 3/4" H

W R

3/4" C W

R

1/2" CW

1/2" HWR

1/2" CW

3/4" CW

3/4" HWR

1 1/2" CW

1/2" CW

R

1/2" HW

R

1/2" CWR

1/2" HWR

1/2" CW

1/2" HW

1 1/2" CW

1 1/2" HW

1 1/2" H W

1 1/2" C W

3/4" C W

R

1" CW

1" CW

3/4" HW

1/2" HWR

1/2" CW

3/4" HW

R

3/4" CW

1 1/2" CW

3/4" CWR

1/2" CW

1" HW

3/4" HWR

3/4" CWR

1/2" CWR

3/4" HWR

/4

C

W

3/4" HWR

3/4" HW

3/4" CW

3/4" HWR

1 1/2" CW

1 1/2" C W

P-413

P-101 P-701

P-413 P-101

P-701

P-701

P-101

P-413

P-413 P-101

P-701

P-701

P-101

P-413

P-503

P-413 P-413

P-101

P-101

P-413

P-403

P-708

P-401

P-402

P-413 P-101

P-701

P-701

P-101

P-413

P-413

P-101

P-701

P-701

P-101 P-413

P-402

P-301

P-101

P-413

P-413

P-101

P-701

1 1/2" HW

3/4" HW

3/4" CW

1/2" HW

1/2" CW

3/4" HW

3/4" HWR

P-812

P-400

DW

3/4" CW

I LL IN O IS

R

.E

SS

E J

FARBE

LICENSED

PROFESSIONAL

OF

ENGINEER

062.069980

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C U s e rs

\I R a p p \D o c u m e n ts \V

IG

H

-M -R ir a p p

X

W

.r v t

/1

/2

:0

:2

A

M

PL102

PLUMBING ISOMETRICS

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA ST.

SUITE 200

317.800.6388

CMTA

10411 Meeting Street

Prospect, Kentucky 40059

502.326.3085

CONSTRUCT TWO NEW GREEN

HOMES 7 & 8

1900 E. MAIN ST., DANVILLE, IL 61832

550-319

7 & 8

04/09/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

PLUMBING WASTE AND VENT

ISOMETRIC

PLUMBING UTILITY ISOMETRIC

FPHB

N0T TO SCALE

FINISH GRADE

CLEAN OUT PLUG

INDEPENT OF PIPE

CLEAN OUT BOX TO BE

18" X 18" X 4" CONCRETE PAD

CLEAN OUT BOX (STAMPED "CO" )

1" CROWN

EXTERIOR 2-WAY CLEANOUT DETAIL

PROVIDE CHECK VALVES

ABOVE THE CEILING

BALL

3/4" HW AND CW

MOP BASIN DETAL

NOT TO SCALE

VALVES

MOP BASIN

RVD

140° F

140° F

140° F

DOMESTIC WATER HEATER PIPING DIAGRAM

NOT TO

SCALE

SPILL TO

FLOOR

DRAIN

UNION

(TYPICAL)

1"

2"

REFER TO PLANS

FOR CONTINUATION

1"

FURNISH AND INSTALL NEOPRENE

PAD UNDER WATER HEATER (TYPICAL).

SET TO

140° F

120° F

(HEAT TRAP)

A

AQUASTATCHECK VALVE

(TYPICAL)

120° F

BRADLEY HIGH-LOW RECIRCULATION STATION MODEL NRS-13-RP5-R1-AQ-H,

4.0 GPM MINIMUM FLOW, RATED AT 58 GPM AT 10 PSI PRESSURE DROP

PROVIDE WITH DIAL THERMOMETER. CONTRACTOR SHALL PIPE PER

THE MANUFACTURER'S RECOMMENDATIONS. SET TO 120° F

T

TEMPERATURE SENSOR

s

TMV

ET

DWH

DP

VALVE

STATION DETAIL (HWBS1)

BALL

CHECK VALVE

NOT TO SCALE

SUPPLY LINE

HOT WATER

RETURN LINE

HOT WATER

ALL HOT WATER RETURN LOOPS

HWBS1

HOT WATER BALANCING

WATTS 909 REDUCED PRESSURE BACKFLOW

PREVENTER WITH STRAINER.

PRESSURE

GAUGE

(TYP.)

P

PIPE AIR GAP

FITTINGS FULL

P

SIZE TO FLOOR DRAIN

DOMESTIC WATER

OUT TO SITE.

REFERENCE SHEET P2.1

FOR CONTINUATION.

MAIN SHUT-OFF

VALVE AT ENTRY.

MEZZANINE

DOMESTIC WATER SERVICE ENTRY DETAILNOT TO

SCALE

DIRT

LEG

PLUG

COCK

UNION

PIPING

TO

EQUIPMENT

REDUCE FROM

SIZELISTED ON

DRAWINGS

DIRT LEG DETAILNOT TO

SCALE

NATURAL GAS -

BELL & GOSSETT TEMP

SETTER MODEL # TSB-3/4(C)

4"

1"

1"

4"3

4"

1"

NO GATE VALVES ALLOWED

1"

2"

1"

2"

1"

1"

2"

4"

FAUCET WITH

INTEGRAL VACUUM

BREAKER

WATER HAMMER

ARRESTOR

(TYPICAL)

VALVE

STATION DETAIL

BALL

CHECK VALVE

NOT TO SCALE

SUPPLY LINE

COLD WATER

RETURN LINE

COLD WATER

COLD WATER BALANCING

I LL IN O IS

R

.E

SS

E J

FARBE

LICENSED

PROFESSIONAL

OF

ENGINEER

062.069980

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C U s e rs

\I R a p p \D o c u m e n ts \V

IG

H

-M -R ir a p p

X

W

.r v t

/1

/2

:0

:2

A

M

PL103

PLUMBING DETAILS

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA ST.

SUITE 200

317.800.6388

CMTA

10411 Meeting Street

Prospect, Kentucky 40059

502.326.3085

CONSTRUCT TWO NEW GREEN

HOMES 7 & 8

1900 E. MAIN ST., DANVILLE, IL 61832

550-319

7 & 8

04/09/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

File details come from the government source that posted it. Updated .