Hazardous-Abatement File of Building 5.xlsx

XLSX spreadsheet 26 KB Posted

Attached to
PN: 438-21-403, Renovate First Floor Kitchen (SF)
Solicitation number
36C26326B0020
Issued by

About this file

This is a Hazardous Abatement File documenting asbestos-containing materials (ACM) inventory in Building 5 across three floors (Ground Level, 1st Floor, and 2nd Floor). The spreadsheet provides a comprehensive room-by-room assessment of friable and non-friable asbestos materials requiring abatement in support of the renovation of the First Floor Kitchen (PN: 438-21-403) at a Department of Veterans Affairs facility under Veterans Integrated Service Network 23.

The inventory identifies multiple material types including Transite (non-friable, predominant material), 9" x 9" Floor Tile/Mastic (non-friable), Pipe Fittings (friable), and Pipe Insulation (friable). Quantities are specified by square footage (sf), linear feet (lf), and count (ea). Ground Level contains 260 sf of damaged floor tile with exposed cut edges in Room E-06. The 1st Floor lists extensive Transite radiator coverings across 45+ rooms plus friable pipe fittings and insulation in several locations, with many items already abated. The 2nd Floor documents similar materials with the majority marked as abated, including substantial carpeted floor tile installations (up to 703 sf in the corridor) and concentrated friable pipe systems in rooms 244-245E. All materials are categorized as AHERA Assessment Category 5, with cost and air monitoring provisions noted for both friable and non-friable abatement. The solicitation (36C26326B0020) amended the bid opening date to November 3, 2026, at 1:00 PM (CT).

View the file

Other files

File Type Posted
JA Johnson Controls_Signed_Redacted.pdf PDF
Contractor Background Investigation Request Form REV 02-04-2025.pdf PDF
Addendum 01_2026-10-09.pdf PDF
VHA ICRA-1.5 July 2 2026_fillable.pdf PDF
Questions and Answers 10.21.2026.docx DOCX document
OF 306 Fillable 2023 ver.pdf PDF
Self Certification of Continuous Service REV 02-12-2025.pdf PDF
36C26326B0020 0003.docx DOCX document
VHA PCRA 2024_1.1_Final.Template_Fillable.pdf PDF
438-21-403 Renovate First Floor Kitchen 2nd sign in.pdf PDF
438-21-403 Renovate First Floor Kitchen sign in.pdf PDF
36C26326B0020 0002.pdf PDF
36C26326B0020 0001.docx DOCX document
Plans 438-21-403 Renovate 1st Floor Kitchen_Part10.pdf PDF
Plans 438-21-403 Renovate 1st Floor Kitchen_Part6.pdf PDF
Plans 438-21-403 Renovate 1st Floor Kitchen_Part12.pdf PDF
Plans 438-21-403 Renovate 1st Floor Kitchen_Part3.pdf PDF
Plans 438-21-403 Renovate 1st Floor Kitchen_Part13.pdf PDF
Specs_Vol 2_2026-08-18.pdf PDF
Wage Determination SD20260028 05.18.2026.pdf PDF
Plans 438-21-403 Renovate 1st Floor Kitchen_Part4.pdf PDF
Plans 438-21-403 Renovate 1st Floor Kitchen_Part7.pdf PDF
36C26326B0020.docx DOCX document
Final SOW 438-21-403 Renovate First Floor for New Kitchen 5.7.26.docx DOCX document
VAAR 852.219-75 Limitations on Subcontracting Cert of Compliance.pdf PDF
Specs_Vol 1_2026-08-18.pdf PDF
Safety or Environmental Violations and EMR Information.pdf PDF
Plans 438-21-403 Renovate 1st Floor Kitchen_Part1.pdf PDF
Plans 438-21-403 Renovate 1st Floor Kitchen_Part9.pdf PDF
VHA ICRA-1.3 Jan 3 2025.pdf PDF
Plans 438-21-403 Renovate 1st Floor Kitchen_Part11.pdf PDF
Plans 438-21-403 Renovate 1st Floor Kitchen_Part8.pdf PDF
Plans 438-21-403 Renovate 1st Floor Kitchen_Part2.pdf PDF
Plans 438-21-403 Renovate 1st Floor Kitchen_Part5.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Building 5 - Ground Level

BUILDING 5 - GROUND LEVEL
BUILDINGFLOORROOMMATERIAL DESCRIPTIONQUANTITYFRIABLEAHERA ASSESSMENT CATEGORYREMARKSFriable Cost and Air MonitoringNon Friable Cost and Air Monitoring
5Ground LevelE 069” x 9” Floor Tile/Mastic260 sfNo4Damaged - Cut Edge Exposed
Total

&"Arial,Regular"&8sf = Square Feet, lf = Linear Feet, ea = Each, c= Corridor

Building 5 - 1st Floor

BUILDING 5 - FIRST FLOOR
BUILDINGFLOORROOMMATERIAL DESCRIPTIONQUANTITYFRIABLEAHERA ASSESSMENT CATEGORYREMARKSFriable Cost and Air MonitoringNon Friable Cost and Air Monitoring
51102Transite12 sfNo5RadiatorAbatedAbated
51103Transite24 sfNo5RadiatorAbatedAbated
51104Transite12 sfNo5RadiatorAbatedAbated
51110Transite24 sfNo5RadiatorAbatedAbated
511119” x 9” Floor Tile/Mastic144 sfNo5Carpeted
51111Pipe Fittings10 eaYes5Above Ceiling & Radiator Pipes
51111Pipe Insulation63 lfYes5Above Ceiling
51111Transite12 sfNo5Radiator
51112Transite72 sfNo5Radiator
51113Transite12 sfNo5Radiator
51114Transite24 sfNo5Radiator
51117Transite60 sfNo5Radiator
51120Transite48 sfNo5RadiatorAbatedAbated
51121Transite12 sfNo5RadiatorAbatedAbated
51122Transite12 sfNo5RadiatorAbatedAbated
51123Transite12 sfNo5RadiatorAbatedAbated
51126Transite24 sfNo5RadiatorAbatedAbated
511279” x 9” Floor Tile/Mastic18 sfNo5In ClosetAbatedAbated
51127Pipe Fittings10 eaYes5Above CeilingAbatedAbated
51127Pipe Insulation44 lfYes5Above CeilingAbatedAbated
51127Transite24 sfNo5Above Ceiling & Radiator Pipes
51132Transite72 sfNo5Radiator
511379” x 9” Floor Tile/MasticNo5Carpeted
51139Transite12 sfNo5Radiator
51140Transite12 sfNo5Radiator
51144Transite12 sfNo5Radiator
511489” x 9” Floor Tile/Mastic336 sfNo5Carpeted
51148Transite24 sfNo5Radiator
51149Transite12 sfNo5Radiator
51150Transite24 sfNo5Radiator
51155Transite12 sfNo5Radiator
511579” x 9” Floor Tile/Mastic204 sfNo5Carpeted
51157Pipe Fittings16 eaYes5Above Ceiling & Radiator Pipes
51157Pipe Insulation82 lfYes5Above Ceiling
51157Transite12 sfNo5Radiator
511589” x 9” Floor Tile/Mastic132 sfNo5Carpeted
51158Pipe Fittings10 eaYes5Above Ceiling
51158Pipe Insulation84 lfYes5Above Ceiling
51158Transite12 sfNo5Radiator
511599” x 9” Floor Tile/Mastic108 sfNo5Carpeted
51159Pipe Fittings8 eaYes5Above Ceiling
51159Pipe Insulation39 lfYes5Above Ceiling
51159Transite12 sfNo5Radiator
511609” x 9” Floor Tile/Mastic120 sfNo5Carpeted
51160Pipe Fittings13 eaYes5Above Ceiling & Radiator Pipes
51160Pipe Insulation78 lfYes5Above Ceiling
51160Transite12 sfNo5Radiator
51161Pipe Fittings19 eaYes5Above Ceiling & Radiator Pipes
51161Pipe Insulation90 lfYes5Above Ceiling
51161Transite36 sfNo5Radiator
511629” x 9” Floor Tile/Mastic180 sfNo5Carpeted
51162Pipe Fittings19 eaYes5Above Ceiling & Radiator Pipes
51162Pipe Insulation60 lfYes5Above Ceiling
51162Transite24 sfNo5Radiator
511639” x 9” Floor Tile/Mastic144 sfNo5Carpeted
51163Pipe Fittings10 eaYes5Above Ceiling & Radiator Pipes
51163Pipe Insulation42 lfYes5Above Ceiling
51163Transite12 sfNo5Radiator
511649” x 9” Floor Tile/Mastic100No5Carpeted
51164Pipe Fittings10 eaYes5Above Ceiling & Radiator Pipes
51164Pipe Insulation30 lfYes5Above Ceiling
51164Transite12 sfNo5Radiator
511659” x 9” Floor Tile/Mastic108 sfNo5Carpeted
51165Pipe Fittings10 eaYes5Above Ceiling & Radiator Pipes
51165Pipe Insulation40 lfYes5Above Ceiling
51165Transite12 sfNo5Radiator
511669” x 9” Floor Tile/Mastic120 sfNo5Carpeted
51166Pipe Fittings10 eaYes5Above Ceiling & Radiator Pipes
51166Pipe Insulation40 lfYes5Above Ceiling
51166Transite12 sfNo5Radiator
511679” x 9” Floor Tile/Mastic120 sfNo5Carpeted
51167Pipe Fittings8 eaYes5Above Ceiling & Radiator Pipes
51167Pipe Insulation46 lfYes5Above Ceiling
51167Transite12 sfNo5Radiator
511689” x 9” Floor Tile/Mastic108 sfNo5Carpeted
51168Pipe Fittings10 eaYes5Above Ceiling & Radiator Pipes
51168Pipe Insulation46 lfYes5Above Ceiling
51168Transite12 sfNo5Radiator
511699” x 9” Floor Tile/Mastic120 sfNo5Carpeted
51169Pipe Fittings8 eaYes5Above Ceiling
51169Pipe Insulation36 lfYes5Above Ceiling
51169Transite12 sfNo5Radiator
511709” x 9” Floor Tile/Mastic120 sfNo5Carpeted
51170Pipe Fittings6 eaYes5Above Ceiling & Radiator Pipes
51170Pipe Insulation40 lfYes5Above Ceiling
51170Transite12 sfNo5Radiator
51171Pipe Fittings6 eaYes5Above Ceiling
51171Pipe Insulation66 lfYes5Above Ceiling
51171Transite24 sfNo5Radiator
511729” x 9” Floor Tile/Mastic130 sfNo5Carpeted
51172Pipe Fittings4 eaYes5Above Ceiling & Radiator Pipes
51172Pipe Insulation30 lfYes5Above Ceiling
51172Transite36 sfNo5Radiator
511739” x 9” Floor Tile/Mastic132 sfNo5Carpeted
51173Pipe Fittings9 eaYes5Above Ceiling & Radiator Pipes
51173Pipe Insulation69 lfYes5Above Ceiling
51173Transite12 sfNo5Radiator
51174Pipe Fittings3 eaYes5Radiator Pipes
51174Transite12 sfNo5Radiator
511759” x 9” Floor Tile/Mastic192 sfNo5CarpetedAbated
51175Pipe Insulation60 lfYes5Above Ceiling
51175Transite12 sfNo5RadiatorAbated
511799” x 9” Floor Tile/Mastic192 sfNo5CarpetedAbated
51179Pipe Fittings5 eaYes5Above Ceiling & Radiator PipesAbated
51179Pipe Insulation44 lfYes5Above CeilingAbated
51179Transite12 sfNo5RadiatorAbated
51106CTransite12 sfNo5Radiator
51106DTransite12 sfNo5Radiator
51106ETransite12 sfNo5Radiator
51106FTransite12 sfNo5Radiator
51111A9” x 9” Floor Tile/Mastic120 sfNo5Carpeted
51111APipe Fittings8 eaYes5Above Ceiling
51111APipe Insulation47 lfYes5Above Ceiling
51111ATransite12 sfNo5Radiator
51142CTransite12 sfNo5Radiator
51Stairwell No. 3Transite12 sfNo5Radiator
Total$0.00$0.00

&"Arial,Regular"&8sf = Square Feet, lf = Linear Feet, ea = Each, c= Corridor

Building 5 - 2nd Floor

BUILDING 5 - SECOND FLOOR
BUILDINGFLOORROOMMATERIAL DESCRIPTIONQUANTITYFRIABLEAHERA ASSESSMENT CATEGORYREMARKSFriable Cost and Air MonitoringNon Friable cost and Air Monitoring
52201Transite12 sfNo5Radiator
52201ATransite18 sfNo5Radiator
52201BTransite18 sfNo5Radiator
52202Transite12 sfNo5Radiator
52204Pipe Fittings13 eaYes5Above CeilingAbated
52204Pipe Insulation48 lfYes5Above CeilingAbated
52204Transite24 sfNo5RadiatorAbated
522059” x 9” Floor Tile/Mastic140 sfNo5Abated
52205Pipe Fittings9 eaYes5Above CeilingAbated
52205Pipe Insulation44 lfYes5Above CeilingAbated
52205Transite12 sfNo5RadiatorAbated
522069” x 9” Floor Tile/Mastic128 sfNo5Abated
52206Pipe Fittings5 eaYes5Above CeilingAbated
52206Pipe Insulation11 lfYes5Above CeilingAbated
52206Transite12 sfNo5RadiatorAbated
52207Pipe Fittings13 eaYes5Above CeilingAbated
52207Pipe Insulation42 lfYes5Above CeilingAbated
52207Transite12 sfNo5RadiatorAbated
522089” x 9” Floor Tile/Mastic160 sfNo5Abated
52208Pipe Fittings8 eaYes5Above CeilingAbated
52208Pipe Insulation9 lfYes5Above CeilingAbated
52208Transite12 sfNo5RadiatorAbated
522099” x 9” Floor Tile/Mastic288 sfNo5Abated
52209Pipe Insulation44 lfYes5Above CeilingAbated
52209Transite24 sfNo5RadiatorAbated
52210Transite12 sf5RadiatorAbated
52215Pipe Fittings10 eaYes5Above CeilingAbated
52215Pipe Insulation33 lfYes5Above CeilingAbated
52215Transite12 sfNo5RadiatorAbated
52216Pipe Fittings8 eaYes5Above CeilingAbated
52216Pipe Insulation10 lfYes5Above CeilingAbated
52216Transite12 sfNo5RadiatorAbated
52217Pipe Fittings8 eaYes5Above CeilingAbated
52217Pipe Insulation48 lfYes5Above CeilingAbated
52217Transite12 sfNo5RadiatorAbated
52218Pipe Fittings10 eaYes5Above CeilingAbated
52218Pipe Insulation10 lfYes5Above CeilingAbated
52218Transite12 sfNo5RadiatorAbated
52219Transite12 sfNo5RadiatorAbated
52220ATransite24 sfNo5RadiatorAbated
52221Transite24 sfNo5RadiatorAbated
52222Pipe Fittings14 eaYes5Above CeilingAbated
52222Pipe Insulation82 lfYes5Above CeilingAbated
52222Transite24 sfNo5RadiatorAbated
52222ATransite12 sfNo5RadiatorAbated
52222BPipe Fittings18 eaYes5Above CeilingAbated
52222BPipe Insulation22 lfYes5Above CeilingAbated
52222BTransite12 sfNo5RadiatorAbated
52223Pipe Fittings10 eaYes5Above CeilingAbated
52223Pipe Insulation42 lfYes5Above CeilingAbated
52223Transite24 sfNo5RadiatorAbated
52224Pipe Fittings6 eaYes5Above CeilingAbated
52224Pipe Insulation8 lfYes5Above CeilingAbated
52224Transite12 sfNo5RadiatorAbated
52225Pipe Fittings9 eaYes5Above CeilingAbated
52225Pipe Insulation42 lfYes5Above CeilingAbated
52225Transite12 sfNo5RadiatorAbated
52226Pipe Fittings6 eaYes5Above CeilingAbated
52226Pipe Insulation12 lfYes5Above CeilingAbated
52226Transite12 sfNo5RadiatorAbated
52227Transite12 sfNo5RadiatorAbated
52229Transite12 sfNo5RadiatorAbated
52230Transite12 sfNo5RadiatorAbated
52234Pipe Fittings7 eaYes5Above CeilingAbated
52234Pipe Insulation5 lfYes5Above CeilingAbated
52235Pipe Fittings8 eaYes5Above CeilingAbated
52235Pipe Insulation20 lfYes5Above CeilingAbated
52236Pipe Fittings17 eaYes5Above CeilingAbated
52236Pipe Insulation99 lfYes5Above CeilingAbated
52236Transite48 sfNo5RadiatorAbated
52238Pipe Fittings6 eaYes5Above CeilingAbated
52238Pipe Insulation15 lfYes5Above CeilingAbated
52238Transite12 sfNo5RadiatorAbated
522399” x 9” Floor Tile/Mastic285 sfNo5Abated
52239Pipe Fittings6 eaYes5Abated
52239Pipe Insulation52 lfYes5Above CeilingAbated
52239Transite24 sfNo5RadiatorAbated
522409” x 9” Floor Tile/Mastic330 sfNo5CarpetedAbated
52240Pipe Fittings8 eaYes5Above CeilingAbated
52240Pipe Insulation52 lfYes5Above CeilingAbated
52240Transite24 sfNo5RadiatorAbated
52243ATransite24 sfNo5Radiator
52244Pipe Fittings84 eaYes5Above Ceiling
52244Pipe Insulation360 lfYes5Above Ceiling
52245Pipe Fittings18 eaYes5Above Ceiling
52245Pipe Insulation69 lfYes5Above Ceiling
52245Transite30 sfNo5Radiator
52245CPipe Fittings18 eaYes5Above Ceiling
52245CPipe Insulation24 lfYes5Above Ceiling
52245DPipe Fittings18 eaYes5Above Ceiling
52245DPipe Insulation24 lfYes5Above Ceiling
52245EPipe Fittings18 eaYes5Above Ceiling
52245EPipe Insulation24 lfYes5Above Ceiling
52247Transite24 sfNo5Radiator
52248Transite24 sfNo5Radiator
52271 Stair No. 2Transite24 sfNo5Radiator
52272Transite24 sfNo5Radiator
52273Transite24 sfNo5Radiator
52274Transite24 sfNo5Radiator
52276Transite12 sfNo5Radiator
52277Transite24 sfNo5Radiator
52279Transite24 sfNo5Radiator
52280Transite12 sfNo5Radiator
52281Transite24 sfNo5Radiator
52282Transite24 sfNo5Radiator
52283Transite24 sfNo5Radiator
52284Transite24 sfNo5Radiator
52286Transite48 sfNo5Radiator
52290Transite24 sfNo5Radiator
52291Transite24 sfNo5Radiator
52C-2879” x 9” Floor Tile/Mastic703 sfNo5Carpeted
52Stair No. 3Transite12 sfNo5Radiator
Total$0.00

&"Arial,Regular"&8sf = Square Feet, lf = Linear Feet, ea = Each, c = Corridor