VA Salt Lake City_Exterior Family of Signs_Footing_R1.pdf

PDF 1 MB Posted

Attached to
Z2DA--660-23- 104/660-23-112 Interior and Exterior Wayfinding
Solicitation number
36C25924R0105
Issued by

About this file

This document appears to be a set of design plans and details for the exterior signage system at the VA Salt Lake City Healthcare System. It includes detailed footing and foundation plans for various types of exterior signs, including primary site identification signs, information center signs, illuminated pylons, non-illuminated pylons, double post and panel signs, and single post and panel signs. The plans show the dimensions, materials, and construction details for each sign type. This appears to be design documentation related to a federal contract opportunity for the VA Salt Lake City Healthcare System's exterior wayfinding signage project, which is solicitation number 36C25924R0105.

View the file

Other files

File Type Posted
36C25924R0105 0005.pdf PDF
Parking Lot ID - Utility Pole Mounted.pdf PDF
101400 Interior Signage readme2.doc DOC document
329300 Landscape 2.docx DOCX document
36C25924R0105 0004.pdf PDF
101400 Exterior Signage readme2.doc DOC document
ICRA Requirements for Wayfinding Project.pdf PDF
VA Salt Lake City - Exterior Sign Qty Schedule.xls XLS spreadsheet
Site Conditions.zip ZIP file
36C25924R0105 0003.docx DOCX document
Floor Plans.zip ZIP file
VA Salt Lake City - Interior Sign Qty Schudule.xls XLS spreadsheet
101400 Exterior Signage readme.doc DOC document
Spec Package.zip ZIP file
Utah Tax Exempt Form 7.11.2023.pdf PDF
Asbestos Maps.zip ZIP file
329300 Landscape.docx DOCX document
36C25924R0105 0002.docx DOCX document
Site Visit Attendance.pdf PDF
36C25924R0105 0001.docx DOCX document
Exterior Signage Drawings Final.pdf PDF
36C25924R0105.docx DOCX document
S02 Past Performance Questionnaire.docx DOCX document
Parking Map SLCVAMC.pdf PDF
Internal Signage Drawings Final.pdf PDF
S22 LOS 852.219-75.docx DOCX document
Internal Signage Schedule Final.xls XLS spreadsheet
Exterior Signage Schedule Final.xls XLS spreadsheet
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET

DESIGNER

DRAWN BY

KH

SCALE

SIGN TYPE

DW-01

REVISIONS

VA Salt Lake City Healthcare System

Exterior Sign Footing Detail

FACILITY

PROJECT

Peter Van Allen Sr.

Exterior Signage Footing

VA Salt Lake City Healthcare System

DRAWN BY

KH

SCALE

SIGN TYPE

DW-02

REVISIONS

VA Salt Lake City Healthcare System

Exterior Sign Footing Detail

FACILITY

PROJECT

Peter Van Allen Sr.

George E. Wahlen VA Medical Center

VA Salt Lake City Health Care System

58”

24”

4”

36”

20” 24”

140”

4”

165”

20”

165”

24”

4”

20”

165”

Internal Breaker Box w/ 20 Amp Breakers w/ Hinged Door & Built in Lock

42”

146”

SOUTH ELEVATION VIEW - FRONT

58”

Poles Centers to be Checked on Site

Internal Framing is Bolted to Steel Pipe at Time of Installation

6” Diameter Steel Pipe O.D.

6” Minimum Distance Between Center of Steel Pipe & Inside Edge of Sign Cabinet

Internal White LED Illumination w/ 120v Power Pack

4”Thick Beveled Cast Limestone Cap Cap Overhang - All Four Sides

Concrete

Recommended 1-1/2” Angle-Iron Bracing-Bolt to Steel Pipe Prior to Installation

Incoming Electrical Feed to Breaker Box

Electrical Disconnect Switch

Masonry Sign Base w/ CMU Backing & Brick Faces

GRADE LEVEL

36”

WEST ELEVATION VIEW - SIDEEAST ELEVATION VIEW - SIDE

Crushed Gravel Bed

PRIMARY SITE ID

FOOTING DETAIL

3/8” =1’-0”

Weephole

Ladder - Type Anchor

NOTE:

Design Intent Footing Drawings Only. Contractor is responsible for obtaining and constructing sign foundations in accordance with stamped engineering drawings.

DRAWN BY

KH

SCALE

SIGN TYPE

DW-03

REVISIONS

VA Salt Lake City Healthcare System

Exterior Sign Footing Detail

FACILITY

PROJECT

Peter Van Allen Sr.

24"

66"

90"

INFORMATION CENTER

FOOTING DETAIL

1/2”=1'

GRADE LEVEL

24"

27"

Weephole

Ladder - Type Anchor

36"

ELEVATION - SIDE

36"

99"

ELEVATION - FRONT

Pole Centers to be Checked on Site

Concrete

Recommended 1-1/2” Angle-Iron Bracing-Bolt to Steel Pipe Prior to Installation

Incoming Electrical Feed to Breaker Box

Electrical Disconnect Switch

Crushed Gravel Bed

4”Thick Beveled Cast Limestone Cap Cap Overhang - All Four Sides

Masonry Sign Base w/ CMU Backing & Brick Faces

4” Diameter Steel Pipe O.D.

12” Minimum Distance Between Center of Steel Pipe & Inside Edge of Sign Cabinet

Internal White LED Illumination w/ 120v Power Pack

Internal Framing is Bolted to Steel Pipe at Time of Installation

PLAN VIEW

32"

104"

4"

20"

90"

NOTE:

Design Intent Footing Drawings Only. Contractor is

DRAWN BY

KH

SCALE

SIGN TYPE

DW-04

REVISIONS

VA Salt Lake City Healthcare System

Exterior Sign Footing Detail

FACILITY

PROJECT

Peter Van Allen Sr.

ELEVATION - FRONT

28"

4"

ELEVATION - SIDE

28"

94"

24" Pole Centers to be Checked on Site

54"

6” Diameter Steel Pipe O.D.

12” Minimum Distance Between Center of Steel Pipe & Inside Edge of Sign Cabinet

31"

Weephole

Ladder - Type Anchor

PLAN VIEW

36”

99"

54" LARGE ILLUMINATED PYLON

FOOTING DETAIL

3/8”=1' Concrete

Recommended 1-1/2” Angle-Iron Bracing-Bolt to Steel Pipe Prior to Installation

Incoming Electrical Feed to Breaker Box

Electrical Disconnect Switch

Crushed Gravel Bed

4”Thick Beveled Cast Limestone Cap Cap Overhang - All Four Sides

Masonry Sign Base w/ CMU Backing & Brick Faces

Internal White LED Illumination w/ 120v Power Pack

Internal Framing is Bolted to Steel Pipe at Time of Installation

GRADE LEVEL

4"

24"

172" 172"

NOTE:

Design Intent Footing Drawings Only. Contractor is

DRAWN BY

KH

SCALE

SIGN TYPE

DW-05

REVISIONS

VA Salt Lake City Healthcare System

Exterior Sign Footing Detail

FACILITY

PROJECT

Peter Van Allen Sr.

21-½” 21-½"

4"

17-½"

4” Diameter Steel Pipe O.D.

12” Minimum Distance Between Center of Steel Pipe & Inside Edge of Sign Cabinet

Pole Centers to be Checked on Site

67"

42"

27"

Weephole

Ladder - Type Anchor

PLAN VIEW

32"

72"

42"

ELEVATION - SIDE ELEVATION - FRONT

MEDIUM ILLUMINATED PYLON

FOOTING DETAIL

1/2”=1'Concrete

Recommended 1-1/2” Angle-Iron Bracing-Bolt to Steel Pipe Prior to Installation

Incoming Electrical Feed to Breaker Box

Electrical Disconnect Switch

Crushed Gravel Bed

4”Thick Beveled Cast Limestone Cap Cap Overhang - All Four Sides

Masonry Sign Base w/ CMU Backing & Brick Faces

Internal White LED Illumination w/ 120v Power Pack

Internal Framing is Bolted to Steel Pipe at Time of Installation

GRADE LEVEL

4"

17-½”

117-½" 117-½"

NOTE:

Design Intent Footing Drawings Only. Contractor is

DRAWN BY

KH

SCALE

SIGN TYPE

DW-06

REVISIONS

VA Salt Lake City Healthcare System

Exterior Sign Footing Detail

FACILITY

PROJECT

Peter Van Allen Sr.

PLAN VIEW

52"

25"

4"

17"17"

4"

47"

36"

20"

4” Diameter Steel Pipe O.D.

6” Minimum Distance Between Center of Steel Pipe & Inside Edge of Sign Cabinet

Weephole

Ladder - Type Anchor

36"

ELEVATION - SIDE

ELEVATION - FRONT

Concrete

Recommended 1-1/2” Angle-Iron Bracing-Bolt to Steel Pipe Prior to Installation

Crushed Gravel Bed

GRADE LEVEL

SMALL NON-ILLUMINATED

PYLON FOOTING DETAIL

1/2”=1'

4”Thick Beveled Cast Limestone Cap Cap Overhang - All Four Sides

Masonry Sign Base w/ CMU Backing & Brick Faces

Internal Framing is Bolted to Steel Pipe at Time of Installation

21"

93"

21"

93"

NOTE:

Design Intent Footing Drawings Only. Contractor is

DRAWN BY

KH

SCALE

SIGN TYPE

DW-07

REVISIONS

VA Salt Lake City Healthcare System

Exterior Sign Footing Detail

FACILITY

PROJECT

Peter Van Allen Sr.

Chamfer

(Exact centers to be verified prior to install)

3/4”=1’-0”

GRADE LEVEL

66”

PLAN VIEW 3 1/4”12”

4”

EQ. EQ.

48”

55 1/2”

5”

48”

72”

48”

Angled Side Faces Road

36” 36”

ELEVATION - FRONT ELEVATION - SIDE

12”

EQ. EQ.

5”

3 1/4”

76”

Concrete Pad w/ Beveled Edges Approx. 4” Above Ground

3 1/4” SQ. Black Extrude Aluminum Posts w/ Key Slot Track for Sign Cabinet

Concrete Footing

LARGE DOUBLE POST & PANEL

FOOTING DETAIL

Crushed Gravel Bed

NOTE:

Design Intent Footing Drawings Only. Contractor is

DRAWN BY

KH

SCALE

SIGN TYPE

DW-08

REVISIONS

VA Salt Lake City Healthcare System

Exterior Sign Footing Detail

FACILITY

PROJECT

Peter Van Allen Sr.

Chamfer

(Exact centers to be verified prior to install)

3/4”=1’-0”

GRADE LEVEL

PLAN VIEW

36” 36”

ELEVATION - FRONT ELEVATION - SIDE

12”

Concrete Pad w/ Beveled Edges Approx. 4” Above Ground

Concrete Footing

3 1/4”12”

54”

36”

4”

EQ.

36”

5"

76”

EQ.

36”

43 1/2”

54”

MEDIUM DOUBLE POST & PANEL

FOOTING DETAIL

EQ. EQ.

76”

5”

3 1/4”

Crushed Gravel Bed

3 1/4” SQ. Black Extrude Aluminum Posts w/ Key Slot Track for Sign Cabinet

NOTE:

Design Intent Footing Drawings Only. Contractor is

DRAWN BY

KH

SCALE

SIGN TYPE

DW-09

REVISIONS

VA Salt Lake City Healthcare System

Exterior Sign Footing Detail

FACILITY

PROJECT

Peter Van Allen Sr.

EQ. EQ.

72”

3-½”

3 1/4”

Chamfer

(Exact centers to be verified prior to install)

3/4”=1’-0”

GRADE LEVEL

30” 30”

ELEVATION - FRONT ELEVATION - SIDE

12”

Concrete Pad w/ Beveled Edges Approx. 4” Above Ground

Concrete Footing

40”

PLAN VIEW

24”

3 1/4”12”

31 1/2”

24”

31 1/2”

3-½”

24”

4”

EQ. EQ.

40”

72”

SMALL DOUBLE POST & PANEL

FOOTING DETAIL

Crushed Gravel Bed

3 1/4” SQ. Black Extrude Aluminum Posts w/ Key Slot Track for Sign Cabinet

NOTE:

Design Intent Footing Drawings Only. Contractor is

DRAWN BY

KH

SCALE

SIGN TYPE

DW-010

REVISIONS

VA Salt Lake City Healthcare System

Exterior Sign Footing Detail

FACILITY

PROJECT

Peter Van Allen Sr.

ELEVATION - SIDE ELEVATION-FRONT

18"

24"

3 1/4"

12"

30"

12"

30"

Concrete Footing

PLAN VIEW

3 1/4"

84" 84"

GRADE LEVEL

3/4”=1’-0”

SINGLE POST & PANEL

FOOTING DETAIL

Crushed Gravel Bed

3 1/4” SQ. Black Extrude Aluminum Posts w/ Key Slot Track for Sign Cabinet

NOTE:

Design Intent Footing Drawings Only. Contractor is

DRAWN BY

KH

SCALE

SIGN TYPE

DW-011

REVISIONS

VA Salt Lake City Healthcare System

Exterior Sign Footing Detail

FACILITY

PROJECT

Peter Van Allen Sr.

36"

Street Name Street Name

168"

32 1/2"

3” Dia. Round Pole, Powder Coated Black

1/2” =1’-0”

Decorative Alum. Cast Post Base Pier, Powder Coated Black

Concrete Footing GRADE LEVEL

Crushed Gravel Bed

18"

ELEVATION-FRONT

SINGLE POST & PANEL

STREET SIGN

FOOTING DETAIL

Approx. 3" Above Ground Concrete Pad w/ Beleved Edge

3"

NOTE:

Design Intent Footing Drawings Only. Contractor is

DRAWN BY

KH

SCALE

SIGN TYPE

DW-012

REVISIONS

VA Salt Lake City Healthcare System

Exterior Sign Footing Detail

FACILITY

PROJECT

Peter Van Allen Sr.

10’-0"

STOP30"

3"

30"

7’-0"

26"

3” Dia. Round Pole, Decorative Alum. Cast Post Base Pier, 36"

Concrete Footing GRADE LEVEL

Crushed Gravel Bed

18"

ELEVATION-FRONT

1/2” =1’-0”

SINGLE POST

TRAFFIC CONTROL SIGN

FOOTING DETAIL

Approx. 3" Above Ground Concrete Pad w/ Beleved Edge

3"

NOTE:

Design Intent Footing Drawings Only. Contractor is

Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Page 11
Page 12