This document is a Statement of Work (SOW) for a federal contract opportunity related to correcting electrical deficiencies at the Rocky Mountain Regional Veterans Affairs Medical Center (RMR VAMC) in Aurora, Colorado.

The key details are:

  • The Department of Veterans Affairs has a requirement to replace nine substation breaker units, five power quality meters, and three power relays that have reached the end of their service life. All replacements must be drop-in, matching the existing components or an approved equal.
  • There is also a requirement to monitor and record surge events on thirty-one 480A/277A V switchgear using the existing SCADA system.
  • Contractor personnel must meet specific qualifications, including OSHA certification requirements, and adhere to strict safety, quality control, and project management protocols.
  • The period of performance is 300 days from the Notice to Proceed. All work must be scheduled and coordinated with the Contracting Officer's Representative to minimize impact on the medical center's operations.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--554-24-106 Correct Electrical Deficiencies, newest first.
File Type Posted
36C25924R0099 0003.docx DOCX document
S06 - REVISED Scope Table 554-24-106 - REATTACHED.pdf PDF
36C25924R0099 0002.docx DOCX document
S04 - Site Visit Attendance.pdf PDF
S06 - REVISED Scope Table 554-24-106.pdf PDF
S05 - RFI ANSWERS 554-24-106 Correct Electrical Deficiencies.pdf PDF
36C25924R0099 0001.docx DOCX document
S22- 852.219-75 LOS Certificate - GC.docx DOCX document
36C25924R0099_1.docx DOCX document
S02 - Past Performance Questionnaire.docx DOCX document
S02 - SOW Attachment 4 DRAFT ICRA - PCRA Electrical Closet Substations.pdf PDF
S02 - SOW Attachment 3 Specifications 554-24-106.pdf PDF
S02 - SOW Attachment 2 Deficiency reports 554-24-106.pdf PDF
S02 - SOW Attachment 1 Scope Table 554-24-106.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project: 554-24-106 Correct Electrical Deficiencies

Additional RFI and Response

1. How many electrical rooms are there?

A: Please refer to the scope table provided on June 27, 2024, in amendment 0001.