This solicitation package includes construction documents and specifications for the renovation of phlebotomy, pathology, histology and other lab spaces at the Tibor Rubin VA Medical Center in Long Beach, California. The scope of work calls for alteration of existing real property in accordance with plans prepared by SRD Architects. Key details include renovation of spaces in building 126 to support phlebotomy, pathology and multiple lab functions. Door schedules and hardware standards are specified. The pre-bid package also references the solicitation number 36C25821B0005 and identifies the contracting agency as the Department of Veterans Affairs Veterans Health Administration VISN 22. Construction services are solicited with responses due according to the attached solicitation IFB and associated attachments.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TYPE A TYPE C TYPE D TYPE E
TYPE F
TYPE B
4"4"
T
L T
TEMPERED GLASS
TEMPERED
GLASS, U.N.O.
TEMPERED
GLASS, U.N.O.
LEGEND
HOLLOW METALHM
AUTOMATIC DOOR OPERATORADO
6"
4"
9" 9"
CARD READER (KEY CARD ACCESS), REFER TO TY- DRAWINGSCR
TYPE G TYPE H
LAMINATED SAFETY GLASSL
TYPE J
UNDER CUT DOORUCD
1. SCHLAGE PRIMUS LARGE FORMAT I/C (INTERCHANGEABLE CORE LOCKS) IS VA
MEDICAL CENTER’S STANDARD FOR CORE/DOOR HARDWARE USED
THROUGHOUT THE FACILITY. CONFORMITY WITH EXISTING HARDWARE SYSTEM
WILL ALLOW FOR SPARE PARTS INVENTORY AND COMPLIANCE WITH EXISTING
KEY SYSTEM.
2. ALL EXIT DOORS SHALL COMPLY WITH IBC 1010.1 1
a. CLEAR WIDTH OF EACH DOOR OPENING SHALL BE MIN. 32"
b. MIN. DOOR HEIGHT OF 6'-8"
c. SHALL BE CAPABLE OF OPENING 90 DEGREES.
d. THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL BE 48” NOMINAL.
e. EXIT DOOR SHALL BE SIDE-HINGED SWINGING TYPE.
3. DOORS SERVING AN AREA THAT HAS AN OCCUPANT LOAD OF 50 OR MORE.
SWING THESE DOORS IN THE DIRECTION OF EGRESS TRAVEL. (IBC 1010.1.2.1)
4. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.50” IN HEIGHT.
5. DOOR HANDLES, LOCK AND OTHER OPERATING DEVICES SHALL BE INSTALLED
AT A MIN. 34” AND A MAX. 48” ABOVE THE FINISHED FLOOR
6. ALL EXIT DOORS FROM BUILDING SHALL HAVE A SIGN: THIS DOOR TO REMAIN
UNLOCKED WHEN BUILDING IS OCCUPIED.
7. ALL EGRESS DOOR OPERATION SHALL COMPLY WITH SECTION IBC 1010.1.9.
8. EACH PANE OF SAFETY GLAZING INSTALLED IN HAZARDOUS LOCATIONS SHALL
BE IDENTIFIED BY A MANUFACTURER’S DESIGNATION AND GLAZING SAFETY
STANDARDS .
9. THE FOLLOWING SPECIFIC HAZARDOUS LOCATIONS SHALL HAVE SAFETY
GLAZING PER IBC SECTION 2406:
a. SWINGING DOORS.
b. FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS
IN SLIDING AND FOLDING DOOR ASSEMBLIES.
c. FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST
EXPOSED EDGE OF THE GLAZING IS WITHIN 24 INCHES (610 MM) ARC OF
EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE
THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES
(1525 MM) ABOVE THE WALKING SURFACE.
10. DOORS AT PART OF ACCESSIBLE MEANS OF EGRESS: MAX FORCE TO OPERATE
DOORS IS LIMITED TO 15-LBs.
11. FLOORS OR LANDINGS ON EACH SIDE OF DOORS TO HAVE THE SAME ELEVATION
PER IBC 1010.1.5.
T
CI
T A
E
S
L
O
R
FI
AC L
HCRA
I T E
C
A N
I
T
E O
N
SE
F
SHIRISH R.DESAI
D
04/30/21
C-20141
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
F
IN
A L
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
S V
A T a s k O rd e r
R e n o v a te
P a th o lo g y H is to lo g y C y to lo g y a n d O th e r
L a b S p a c e s \C
A D
\A rc h \6
-1
-1
P a th o lo g y .r v t
/2
/2
:0
:0
P
M
AE-601
DOOR TYPES AND SCHEDULE RENOVATE PATHOLOGY, HISTOLOGY
/ CYTOLOGY, OTHER LAB SPACES
B126 / B7 SWING SPACE
TIBOR RUBIN VA MEDICAL CTR.
600-14-116
10/11/2019 S.D. W.H.
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
GENERAL NOTES
DOOR SCHEDULE
DOOR
NO. ROOM NAME
ROOM
NUMBER
DOOR FRAME
MATERIAL
DETAIL (AE-602) FIRE
RATING
DOOR
HARDWARE REMARKSTYPE WIDTH HEIGHT THICKNESS MATERIAL FINISH HEAD JAMB SILL
FIRST FLOOR
EXISTING (FUTURE USE)
W128M (E) INTERVIEW RM (E)W-128M B 3' - 0" 7' - 0" 0' - 1 3/4" HM WOOD B5 B3 - 3G
W128Q (E) EXAM RM (E)W-128C B 3' - 0" 7' - 0" 0' - 1 3/4" HM WOOD B5 B3 - 3G
PHLEBOTOMY
W123 ELECT RM W-123 B 3' - 6" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9 90 MIN 5D
W124 HAC W-124 A 3' - 6" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F7 90 MIN 5D
W127A SUPERVISOR
OFFICE
W-127A B 3' - 0" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 - 3G ACOUSTICAL DOOR
W127B STORAGE W-127B A 3' - 8" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 - 4K
W127C PROCESSING W-127C A 3' - 8" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 - SH-4 CR
W127D STORAGE W-127D A 3' - 8" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F9 4K
W127E STAFF TOILET W-127E B 3' - 6" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F5 2
W128.2 PHLEBOTOMY W-128 A 4' - 0" 7' - 0" 0' - 1 3/4" HM PT HM B7 B3 F9 90 MIN SH-4A CR, ADO
W128A BLOOD DRAW 5 W-128A E 3' - 7" 7' - 0" 0' - 1 3/4" ALUM ALUM ALUM D9 D5 D9 SEE SPEC
W128B BLOOD DRAW 4 W-128B E 3' - 7" 7' - 0" 0' - 1 3/4" ALUM ALUM ALUM D9 D5 D9 SEE SPEC
W128C BLOOD DRAW 3 W-128C E 3' - 7" 7' - 0" 0' - 1 3/4" ALUM ALUM ALUM D9 D5 D9 SEE SPEC
W128D BLOOD DRAW 2 W-128D E 3' - 7" 7' - 0" 0' - 1 3/4" ALUM ALUM ALUM D9 D5 D9 SEE SPEC
W128E BLOOD DRAW 1 W-128E E 3' - 7" 7' - 0" 0' - 1 3/4" ALUM ALUM ALUM D9 D5 D9 SEE SPEC
W128F BLOOD DRAW 6 W-128F E 3' - 7" 7' - 0" 0' - 1 3/4" ALUM ALUM ALUM D9 D5 D9 SEE SPEC
W128G BLOOD DRAW 7 W-128G E 3' - 7" 7' - 0" 0' - 1 3/4" ALUM ALUM ALUM D9 D5 D9 SEE SPEC
W128H BLOOD DRAW 8 W-128H E 3' - 7" 7' - 0" 0' - 1 3/4" ALUM ALUM ALUM D9 D5 D9 SEE SPEC
W128I BLOOD DRAW 9 W-128I E 3' - 7" 7' - 0" 0' - 1 3/4" ALUM ALUM ALUM D9 D5 D9 SEE SPEC
W128J BLOOD DRAW 10 W-128J E 3' - 7" 7' - 0" 0' - 1 3/4" ALUM ALUM ALUM D9 D5 D9 SEE SPEC
W128K HALLWAY W-128K C 3' - 6" 7' - 0" 0' - 1 3/4" ALUM WOOD HM B5 B3 - SH-4 CR
W129 FAC W-129 B 2' - 6" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9 NON
RATED
5D
W130 PATIENT TOILET W-130 B 3' - 6" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F5 2
W130A PATIENT TOILET W-130A B 3' - 6" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F5 2
W169 WAITING W-169 F 9' - 0" 8' - 0" STEEL STEEL - - - SEE SPEC POWER OPERATED ROLL-UP GATE
W169.2 PHLEBOTOMY W-128 A 4' - 0" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 - SH-4 CR
W169.3 RECEPTION W-169A H 3' - 0" 2' - 7" 0' - 1 3/4" WOOD PL - - - RECEPTION DESK SWING GATE
W169A RECEPTION W-169A G 7' - 7" 8' - 0" STEEL STEEL - - - SEE SPEC POWER OPERATED ROLL-UP GATE
SECOND FLOOR
ACCESSIONING
E222 ACCESSIONING E-222 A 3' - 8" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F9 20 MIN. SH-3H CR, HOLD OPEN
BIOMED
E219B BIOMED E-219B A 3' - 6" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F5 NON
RATED
3G 3/4" UCD
COMMON AREA
E202 PATIENT TOILET E-202 B 3' - 6" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F5 - 2
E204 DRUG TESTING
PATIENT TOILET
E-203 B 3' - 6" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F5 20 MIN. 2
E255 ADA STAFF TOILET E-255 B 3' - 0" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F5 20 MIN 2 3/4" UCD
E259 (E) ELEC E-259 B 3' - 0" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9
E260 (E) S&T E-260 B 3' - 0" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9
EC22 CORRIDOR E-C2-2 J 5' - 0" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9 90 MIN 12A HOLD OPEN
EC27 (E) CORRIDOR E-C2-5 D 5' - 6" 7' - 0" 0' - 1 3/4" HM PT HM B7 B3 F9 45 MIN. 12H CR, ADO
EC29 (E) CORRIDOR E-C2-9 D 5' - 6" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9 90 MIN 12A HOLD OPEN
EC210 CORRIDOR E-C2-10 C 3' - 8" 7' - 0" 0' - 1 3/4" HM PT HM B7 B3 F9 90 MIN SH-4A CR, ADO
EC213 FIRE RISER E-256 B 3' - 0" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9 5D 3/4" UCD
EC214 ELECTRICAL ROOM E-231 B 3' - 0" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 - 5D 3/4" UCD
HISTOLOGY/CYTOLOGY
W231 OFFICE W-231 A 3' - 0" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 - NON
RATED
3G 3/4" UCD
W231A CYTO STORAGE W-231A A 3' - 8" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F9 45 MIN 5B 3/4" UCD
W231B SUPERVISOR
OFFICE
W-231B B 3' - 0" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 - NON
RATED
3G 3/4" UCD
W231C HISTOLOGY/CYTOLO
GY
W-231C C 3' - 8" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 - NON
RATED
4K
W231D GROSS W-231D C 3' - 8" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 - NON
RATED
4K
W231E IMMUNO-HISTOLOG
Y CHEMISTRY
W-231-E C 3' - 8" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 - NON
RATED
4K
W231O RECEIVING W-231O A 3' - 8" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 - - 4K 3/4" UCD
W231P GIP STORAGE W-231P A 3' - 8" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9 90 MIN SH-3H CR
W231S1 STAFF LOUNGE W-231S A 3' - 8" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9 90 MIN SH-4 CR
W231S2 STAFF LOUNGE W-231S A 3' - 6" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 - NON
RATED
W232 WOMEN'S STAFF
TOILET
W-232 B 3' - 0" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F5 - 2 3/4" UCD
W233 MEN'S STAFF TOILET W-233 B 3' - 0" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F5 2 3/4" UCD
W233A HISTOLOGY
EQUIPMENT
STORAGE
W-233A A 3' - 8" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F9 45 MIN 5B
W233C LAB STORAGE W-233C A 3' - 8" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9 90 MIN SH-3H CR
WC210 CORRIDOR W-C2-10 C 3' - 8" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9 90 MIN SH-4 CR
WC212 CORRIDOR W-C2-12 A 3' - 8" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9 90 MIN SH-4 CR
WC213 H.A.C. W-C2-13 A 3' - 6" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F5 90 MIN 5D
MOLECULAR PATHOLOGY
E223 MOLECULAR
PATHOLOGY
E-223 A 3' - 6" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9 20 MIN. SH-3H
E223A MOLECULAR LAB - A E-223A A 3' - 6" 7' - 0" 0' - 1 3/4" HM PT HM B5 B3 F9 20 MIN. SH-3H
SPECIAL PROCEDURES
E206 REFER. / FREEZER E-206 A 3' - 6" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F5 20 MIN. SH-3H CR
E219 OFFICE E-219 B 3' - 0" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 - 3G 3/4" UCD
E222A SPECIAL
PROCEDURES
E-222A A 3' - 8" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F9 20 MIN. SH-3H CR, HOLD OPEN
E257 TECH OFFICE E-257 A 3' - 0" 7' - 0" 0' - 1 3/4" WOOD WOOD HM B5 B3 F9 20 MIN. 3G
DOOR TYPE
1/4" = 1'-0"E1
Long Beach VA Medical Center uses Allegion as bases of design for doors and door hardware.
Long Beach VA Medical Center personnel are trained in the installation and maintenance of the above material. The Maintenance Department owns considerable stock of materials for repair work. Long Beach VA Medical Center is not prepared to accommodate the adoption of an additional hardware standard.
Hollow Metal Doors Exterior: Steelcraft “L” series honeycomb core 16ga Interior: Steelcraft “L” series honeycomb core 18ga
Door Seals Zero or Pemco: 290AS finish aluminum (jamb) Zero or Pemco: 2891AS finish aluminum (head) Zero or Pemco: 3452 CP 628 finish (bottom seal)
Hinges Conventional: Ives - steel or stainless-steel with concealed bearings, finish to match door hardware...
Overhead Stops Glynn Johnson 90 series and 100 series as required. Use only where floor and wall stops are inadvisable.
Kickplate Ives 8400 series.
Door Stops Ives FS436 with riser R435 at interior
Automatic Flush Bolts Ives: FB30/FB40 Series, use LBR type when possible, finish 626
Lock Guards Ives: LG Series as required for lock application, finish 626
Automatic Operators Horton Automatics
Surface Closers LCN: 4041XP Series finish 689, provide EDA arms at high traffic doors, verify installation application in field and provide any...
Electronic Access Identive Hirsh System
Mullions Von Duprin 99 series Von Duprin 33a series on narrow stile doors
Exit Devices Von Duprin 99 series, Von Duprin 33a series on narrow stile doors
Padlocks American or Schlage with to accept Full Size Interchangeable Core
Rim Cyls Full Size Schlage Primus Full Size Interchangeable Core
Cylindrical: Schlage ND Series RHO lever, finish 626 Locks
Mortise: Schlage L9000 x 06A lever, finish 626
Key System Schlage: Primus, FSIC, verify keyway with locksmith, Tim Garcia (562) 826-8000, timothy.garcia@va.gov
NOTE: Long Beach VA Medical Center uses the following door and hardware products in new construction, in renovation and tenant improvement work.
VA DOOR HARDWARE STANDARD
Revisions: Date:
35% SCHEMATIC DESIGN SUBMISSION 08/31/2018
65% DESIGN DEVELOPMENT SUBMISSION 01/25/2019
95% CONSTRUCTION DOCUMENTS SUMISSION 05/31/2019
FINAL CONSTRUCTION DOCUMENTS SUBMISSION 10/11/2019
ADDENDUM 1 02/10/2021
| Sheets |
| AE-601 - DOOR TYPES AND SCHEDULE |