This document includes a solicitation for construction services and related project documents. The Department of Veterans Affairs intends to solicit fixed-price bids to provide construction services for Project 501-CSI-108 to prepare the site for a Nuclear Medicine Support Space at the New Mexico VA Health Care System in Albuquerque. Scope of work includes demolition, site work, and modifications to HVAC, plumbing, electrical, IT, fire suppression and architectural buildouts. The solicitation will be set aside for Service-Disabled Veteran-Owned Small Businesses and is expected to issue on July 20, 2020 via SAM.gov. The project budget is between $100,000 to $250,000 and work must be completed within 272 calendar days of the notice to proceed. Interested vendors should monitor SAM.gov for the solicitation and any amendments. The bidding and award process will follow FAR Part 14.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F6
TYPICAL FRAME
H E
IG
H
T
2" WIDTH 2"
F5
F6
DUAL EGRESS
H E
IG
H
T
2" WIDTH 2"
F5
F6
CASED OPENING
H E
IG
H
T
2" WIDTH 2"
F5
F6
W/ (1) SIDELIGHT
H E
IG
H
T
2" WIDTH 2" VERIFY
2"
F5
1 2 3 4
F5
TERMINATED
STOPS @
INTERIOR
DOORS
TERMINATED
STOPS @
INTERIOR
DOORS
DOOR PANEL AND FRAME NOTES
1. PROVIDE RADIATION RESISTANT DOOR
PANELS AS INDICATED (SEE SPECIFICATIONS)
2. ALL INTERIOR FRAMES SHALL HAVE
TERMINATED STOPS
3. ST-1 MATCH STAIN TO CAMPUS STANDARD
WOOD DOOR STAIN. VERIFY COLOR WITH
CAMPUS INTERIOR DESIGNER.
NOTES
1. SEE DOOR SCHEDULE FOR DOOR WIDTH
AND HEIGHT
2. INSET FRAME DEPTH/THROAT IS 6" UNLESS
OTHERWISE NOTED
3. INSET FRAME'S HEAD WIDTH IS 2" UNLESS
DENOTED AS MASONRY HEAD
4. WRAPPED FRAME'S HEAD WIDTH IS 2"
1'-0" 3"
NF
T
T
G
6"6"
FLUSH NARROW VISION HALF GLASS
1'-0" 3"
U
T
UNEVEN WITH
NARROW VISION
/2
V
A R
IE
S
S E
E P
L A
N /2
4" 2"
ADJACENT WALL
WHERE OCCURS
SEALANT - EA SIDE &
ALL AROUND, TYP.
HOLLOW METAL
FRAME
WALL - SEE PLAN
FOR TYPE
1/2" 1/2"
VARIES
SEE PLAN
WALL - SEE PLAN
FOR TYPE
SEALANT - EA. SIDE &
ALL AROUND, TYP.
HOLLOW METAL FRAME
1ST FLOOR = 82'
0' - 0"
W1
T
H E
IG
H
T S
IL
L
H E
IG
H
T
WIDTH
F4 F3
F1
/8
1/2"
VARIES
1/2"
1 3/4" VARIES 1 3/4"
5/8" TYPE "X" LEAD
LINED GYPSUM BOARD
WALL - SEE FLOOR PLAN
FOR WALL TYPES
(2) 20 GAUGE METAL STUDS
3" x 2-1/2" x 3/8" x CONTINUOUS
STEEL ANGLE - INSTALL STEEL
CLIP ANGLES AT FLOOR AND
STRUCTURE ABOVE
HOLLOW METAL FRAME
SHEET LEAD W/ EQUAL
THICKNESS TO ADJACENT WALL
1/4" STEEL SPACER
-WELD TO STEEL ANGLE
AND HOLLOW METAL FRAME
LEAD LINED DOOR AS SCHEDULED
INPATIENT PETNEW VESTULE
2"
1/2" 1/2"
VARIES
SEE PLAN
WALL - SEE PLAN FOR
TYPE
SEALANT - EA. SIDE & ALL
AROUND, TYP.
HOLLOW METAL FRAME
SCREW APPLIED STOP
GLASS
1/ 2"
V A
R
IE
S S
E E
P
LA
N 1/
2"
4" 2"
ADJACENT WALL WHERE
OCCURS
SEALANT - EA SIDE & ALL
AROUND, TYP.
HOLLOW METAL FRAME
WALL - SEE PLAN FOR
TYPE
SCREW APPLIED STOP
GLASS
2"
1/2"
VARIES
SEE PLAN 1/2"
GLASS
SCREW APPLIED STOP
SEALANT, TYP.
WALL - SEE PLAN FOR
TYPE
HOLLOW METAL FRAME
1/4" = 1'-0"
WRAPPED FRAME TYPES ELEVATIONS
1/4" = 1'-0"
SIDE-HINGED DOOR TYPES
DOOR AND FRAME SCHEDULE
IDENTIFICATION DIMENSIONS PANEL FRAME
SILL
HEIGHT
FIRE
RATING
STC
RATING
HARDWARE
NOTESDOOR NO. ROOM NO. ROOM NAME W H T TYPE MATERIAL
PANEL
FINISH GLAZING TYPE MATERIAL FINISH
FRAME DETAIL
GROUP ELECTRICALHEAD JAMB SILL
1C-184 1C-184 PATIENT WAITING ROOM 4' - 0" 7' - 0" 0' - 1 3/4" F WD ST-1 T 1 HM P-1 F6/A-610 F5/A-610 - 0" 3E
103 1C-103 INPATIENT PET 4' - 0" 7' - 0" 0' - 1 3/4" F WD ST-1 T 1 HM P-1 F8/A-610 F8/A-610 -- 0" 1B 3.175MM (1/8") LEAD LINED
106 1C-106 NEW WAITING 3' - 0" 7' - 0" 0' - 1 3/4" F WD ST-1 T 1 HM P-1 F6/A-610 F5/A-610 -- 0" 2
107 1C-107 NEW WAITING 3' - 0" 7' - 0" 0' - 1 3/4" F WD ST-1 T 1 HM P-1 F6/A-610 F5/A-610 -- 0" 2
109 1C-109 NEW OFFICE 3' - 0" 7' - 0" 0' - 1 3/4" N WD ST-1 -- 1 HM P-1 F6/A-610 F5/A-610 -- 0" 3E
EXISTING C1-25 CORRIDOR 3' - 0" 7' - 0" 0' - 1 3/4" EXISTING EXISTING 0"
EXISTING 1C-112 NEW VESTIBULE 3' - 0" 7' - 0" 0' - 1 3/4" EXISTING EXISTING 0"
EXISTING 1C-160H TOILET 3' - 0" 7' - 0" 0' - 1 3/4" EXISTING EXISTING 0" 45 MIN
EXISTING 1C-108 NEW HALL 3' - 0" 7' - 0" 0' - 1 3/4" EXISTING EXISTING 0" 45 MIN 2A ADO THIS DOOR TO RECIEVE NEW ADA PUSH BUTTON; SEE ELECTRICAL DRAWINGS FOR DETAILS
3" = 1'-0" F5
JAMB 3
3" = 1'-0"
F6
HEAD 4
1/4" = 1'-0"
INTERIOR WINDOW 'W1'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Mechanical, Electrical and Plumbing:
C U s e rs
\K e v in
\D o w n lo a d s \5
-C
S I-
N u c le a r
M e d ic in e \0
W o rk in g F ile s \0
R e v it F ile s \V
A -A
B Q
-B ld g -N u k e M e d -A
R C
H .c o m d e ta c h e d .r v t
/6
/2
:0
:0
A
M
A-610
ARCHITECTURAL DOOR AND
FRAME TYPES
TRIPLE C The A/E Group
1839 S. Alma School Rd., Ste. 300
Mesa, AZ 85210
307-460-2054
Mat Perkins
PREPARE SITE FOR NUCLEAR
MEDICINE SUPPORT SPACE - B41
1501 San Pedro Dr. SE, Albuquerque, NM 87108
501-CSI-108
April 06, 2020 M. PERKINS D. YOUNG
ISSUED FOR
CONSTRUCTION
Window Schedule
Type Count Height Width Head Height Sill Height Fire Rating
Door Window Material Thickness
24" x 48" 1 4' - 0" 2' - 0" 7' - 0" 3' - 0"
3" = 1'-0" F8
LEAD LINED HOLLOW METAL DOOR JAMB
DETAIL (HEAD SIMILAR)
3" = 1'-0" F4
HM - HEAD 6
3" = 1'-0"
F3
HM - JAMB 5
3" = 1'-0" F1
HM - SILL 2
Revisions: Date:
ADDENDUM 1 08/08/2019
ADDENDUM 2 03/31/2020
Expires 6.30.16Expires: 6/30/1821
4/6 /20
REVISION 3 08/10/2020
File details come from the government source that posted it. Updated .