S06_A101 R3 Sheet Updated 08102020.pdf

PDF 892 KB Posted

Attached to
Z1DA--501-CSI-108 Prepare Site for Nuclear Medicine Support Space (VA-19-00084767)
Solicitation number
36C25820B0017
Issued by

About this file

This document describes a federal solicitation for construction services. The Department of Veterans Affairs intends to solicit bids to provide construction services for project 501-CSI-108 to prepare a site for nuclear medicine support space at the New Mexico VA Health Care System in Albuquerque. The services include demolition, HVAC, plumbing, electrical, and architectural renovations. Bids will be evaluated based on price using the Low Price Technically Acceptable process. The award will be made to the responsible bidder providing the lowest price. The solicitation is designated as a 100% small business set-aside for Service-Disabled Veteran-Owned Small Businesses. The delivery schedule is 272 calendar days from notice to proceed, and the project magnitude is estimated between $100,000 to $250,000. The NAICS code is 236220.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T

T

T

T

T

E

7 8 9 10 11

NUCLEAR

MEDICINE

1B-105

415 SF

OFFICE/

MEETING

1B-1391B-139

MEDICAL

OFFICE

1B-1441B-144

LOCKER

1B-1581B-158

TOILET

1B-158A1B-158A

TOILET

1B-1571B-157

NUC

MED

READING

1B-1611B-161

NUC

MED

PHARMACY

1B-1621B-162

EQUIP

STORAGE

1B-1631B-163

RADIO

WASTE

1B-162A1B-162A

PHYSCIAN

ON

DUTY

1B-1681B-168

STAFF

ONLY

1B-1671B-167

NURSE

1B-1691B-169

UTILITY

1B-169A1B-169A

EQUIP

RM

1C-160K1C-160K

SCANNER

RM

1C-1601C-160

UP

TAKER

1C-160D1C-160D

BATH

RM

1C-160C1C-160C

CONTROL

RM

1C-160E1C-160E

PATIENT

WAITING

ROOM

1C-184

100 SF

READING

ROOM

1C-160A1C-160A

RECEPTION

1C-100A1C-100A

READING

RM

1C-1261C-126

BUILDING

MAIN

CLOSET

1B-1041B-104

FEMALE

TOILET

1B-1021B-102

CORRIDOR

C1-25C1-25

CORRIDOR

XX

CORRIDOR

C1-19C1-19

CORRIDOR

C1-22C1-22

CORRIDOR

C1-21C1-21

TOILET

1C-160H1C-160H

INPATIENT

PET

1C-103

111 SF

NEW

WAITING

1C-106

40 SF

NEW

WAITING

1C-107

38 SF

NEW

HALL

1C-108

127 SF

NEW

OFFICE

1C-109

49 SF

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

NEW

VESTIBULE

1C-1121C-112

EXISTING

CONTROL

ROOM#2

1C-131

97 SF

CONTROL

ROOM#1

1C-132

131 SF

ROOM

#2

1B-120

326 SF

ROOM

#1

1B-113

330 SF

ROOM

#3

1B-130

310 SF

ROOM

#4

1B-123

282 SF

3294 3295

10'-8"

A-401

B1

U4

U

U4 L2

U4 L2

U4 L1

U

W1

A-401

C1

WORK

AREA

1B-140

24 SF

NUCLEAR

MEDICINE

1B-105

415 SF

A-401

E1

A5180

CC / CC

U

L2

EXISTING EXISTING

U4

8'-4" 3'-5 1/2" 2'-6 3/4" 1'-10 1/4"

1'-0"

3'-7"

CORRIDOR

C1-25C1-25

DRESSING

RM

1C-123D1C-123D

MAMMOGRAPHY

OFFICE

1C-1241C-124

MULT-VIEW

1C-123A1C-123A

HAC

1C-1271C-127 8'-4" 1'-9 1/2"

/4

/4

/2

U

L2 N L2

N L

EXISTING

2'-7 1/4"

A L

IG

N

N L

A5077

VA / CC

A5077

VA / CC

A5077

VA / CC

1C-184

A5180

CC / CC

GENERAL NOTES

REFERENCE KEYNOTES

KEY PLAN

A. REFER TO A-101 FOR TYPICAL ENLARGED PLANS.

B. ALL DIMENSIONS ARE TO FACE GYP BD UNLESS NOTED OTHERWISE.

C. REFER TO A-501 FOR PARTITION TYPES.

D. ALL DOORS ARE 4" FROM THE CORNER OF THE ADJACENT WALL TO THE

INSIDE OF THE FACE OF THE FRAME UNLESS NOTED OTHERWISE.

E. DOORS AND WINDOWS ARE DIMENSIONED TO CENTERLINE UNLESS NOTED

OTHERWISE.

LEGEND

PROJECT BOUNDARY

NOT IN SCOPE/ NO WORK THIS AREA

LEAD LINED PARTITION. SEE PLAN AND WALL TYPES

NON-RATED PARTITION. SEE PLAN AND WALL TYPES

A. ALL INTERIOR WALLS TO BE 3-5/8" METAL STUDS UNLESS NOTED OR DIMENSIONED

OTHERWISE. ALL "CLEAR" OR "MIN." DIMENSIONS ARE DIMENSIONED FROM FACE OF

FINISH. TYPICALLY, ALL DIMENSIONS ARE FACE OF STUD OR CMU.

THE TYPICAL PARTITION TAG SYMBOL DESIGNATION HAS TWO CHARACTERS. THE

FIRST CHARACTER IS A LETTER INDICATING THE PARTITION TYPE, THE SECOND

CHARACTER IS A NUMERIC INDICATION OF THE STUD OR CMU WIDTH. IF A "≠"

SYMBOL IS SHOWN AS THE FIRST CHARACTER, THIS INDICATES THE PARTITION DOES

NOT HAVE SOUND ATTENUATION. IN SOME INSTANCES, AN ADDITIONAL CHARACTER

OR "MODIFIER" MAY BE ADDED TO THE END AND/OR THE LINE BELOW TO INDICATE

ADDITIONAL CHARACTERISTICS WITHIN THE WALL. REFER TO CHART BELOW FOR

MODIFIER DEFINITIONS.

IF NO PARTITION TAG OR NUMERIC SECOND CHARACTER EXISTS, THE STUD SIZE

WILL BE 3 5/8" TYPICAL, UNO

PARTITION TAGGING LEGEND:

PARTITION

MODIFIER MODIFIER DESCRIPTION

PARTITION

MODIFIER II

≠ X# X

SYMBOL INDICATES PARTITION TYPE

NO SOUND

ATTENUATION STUD/CMU WIDTH

PARTITION MODIFIER II PARTITION MODIFIER

(SEE CHART BELOW) (SEE CHART BELOW)

NUMERIC STUD CMU

CHARACTER WIDTH WIDTH

1 1 5/8" 2 2 1/2"

3 5/8" 4 4" 3 5/8" 6 6" 5 5/8" 8 8" 7 5/8" 12 11 5/8"

X

L1 PROVIDE LEAD 12.700MM SHIELDING ON RADIOGRAPHIC SIDE OF ROOM

SEE DETAIL C1/A-521. HEIGHT OF SHIELDING 7' AFF

L2 PROVIDE LEAD 3.175MM SHIELDING ON RADIOGRAPHIC SIDE OF ROOM

SEE DETAIL C1/A-521. HEIGHT OF SHIELDING 7' AFF

2 HR FIRE & SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE BARRIER/SHAFT

1 HR FIRE & SMOKE BARRIER

1 HR FIRE BARRIER

1 HR FIRE BARRIER/SHAFT

SMOKE PARTITION (NON RATED)

NON RATED

PRIORITY

1 HIGHEST

4 LOWEST

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Mechanical, Electrical and Plumbing:

C U s e rs

\K e v in

\D o w n lo a d s \5

-C

S I-

N u c le a r

M e d ic in e \0

W o rk in g F ile s \0

R e v it F ile s \V

A -A

B Q

-B ld g -N u k e M e d -A

R C

H .c o m d e ta c h e d .r v t

/6

/2

:0

:4

A

M

A-101

ARCHITECTURAL ENLARGED PLAN

TRIPLE C The A/E Group

1839 S. Alma School Rd., Ste. 300

Mesa, AZ 85210

307-460-2054

Mat Perkins

PREPARE SITE FOR NUCLEAR

MEDICINE SUPPORT SPACE - B41

1501 San Pedro Dr. SE, Albuquerque, NM 87108

501-CSI-108

April 06, 2020 M. PERKINS D. YOUNG

ISSUED FOR

CONSTRUCTION

1/4" = 1'-0" F1

ARCHITECTURAL ENLARGED FLOOR PLAN

1 NEW NON-RATED 48"X84" DOOR WITH HOLD OPEN, NO PUSH BUTTON REQUIRED

2 NOT USED

3 NEW CCTV, SEE ELECTRICAL PLANS

4 NEW PRIVACY CURTAIN, RENAL TYPE

5 NEW 4 ADDITIONAL 20 AMP CIRCUITS. PROVIDE AT LEAST ONE EMERGENCY CIRCUIT IN EMERGENCY

AREA INCLUDINGD EMERGENCY LIGHTING. PROVIDE FIRE-RATED ACCESS DOOR PANEL., SEE

ELECTRICAL PLANS

6 NEW OXYGEN, VAC, MED AIR, AND NURSE CALL (GOES BACK TO PET CONTROL ROOM), SEE

MECHANICAL DRAWINGS

7 EXISTING FIRE RATED CORRIDOR TO REMAIN OPERATIONAL

8 EXISTING FIRE-RATED 36" DOOR TO REMAIN, PROVIDE NEW ADA PUSH BUTTON DOOR, SEE

ELECTRICAL DRAWINGS

9 NEW NURSE CALL MONITOR

AREA B B42

B41 - LEVEL 1

AREA C

AREA

OF

WORK

Revisions: Date:

ADDENDUM 1 08/08/2019

ADDENDUM 2 03/31/2020

Expires 6.30.16Expires: 6/30/1821

4/6 /20

REVISION 3 08/10/2020