This document provides details for a federal construction contract opportunity to prepare a site for a Nuclear Medicine Support Space project at the New Mexico VA Health Care System in Albuquerque, New Mexico. The contractor shall demolish existing site elements, furnish labor and materials, and perform work required by drawings and specifications, including modifications to HVAC, plumbing, electrical, IT, and fire suppression systems, as well as architectural renovations with built-in counters and cabinetry. The project involves work in rooms 1B-160, 1C-160G, and interstitial spaces of Building 41. The Department of Veterans Affairs will solicit fixed-price bids evaluated for low price responsiveness. The solicitation will be set aside for a Service-Disabled Veteran-Owned Small Business and released on or around July 20, 2020, with a bid acceptance period of ninety days and bid bond required. The period of performance is 272 calendar days from notice to proceed, and the project value is between $100,000 to $250,000.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NMVAHCS Albuquerque, NM #501-CSI-108 Prepare Site for Nuclear Medicine Support Space - IFC August 13, 2020

ACCESS DOORS AND FRAMES

08 31 13 - 1

SECTION 08 31 13

ACCESS DOORS AND FRAMES

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Access doors and panels installed in ceilings.

1.2 RELATED REQUIREMENTS

A. Lock Cylinders: Section 08 71 00, DOOR HARDWARE.

B. Field Painting: Section 09 91 00, PAINTING.

1.3 APPLICABLE PUBLICATIONS

A. Comply with references to extent specified in this section.

B. American Welding Society (AWS):

D1.3/D1.3M-08 Structural Welding Code - Sheet Steel.

C. ASTM International (ASTM):

A653/A653M-15 Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated

(Galvannealed) by the Hot-Sip Process.

A1008/A1008M-15 Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength

Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Baked Hardenable.

A666-15 Annealed or Cold-Worked Austenitic Stainless Steel sheet, Strip, Plate, and Flat Bar.

E119-15 Fire Test of Building Construction and Materials.

D. National Fire Protection Association (NFPA):

80-16 Fire Doors and Other Opening Protectives.

251-12 Fire Tests of Door Assemblies.

E. National Association of Architectural Metal Manufacturers (NAAMM):

AMP 500-06 Metal Finishes Manual.

F. UL LLC (UL):

Listed Online Certifications Directory.

10B-08 Standard for Fire Tests of Door Assemblies.

263-11 Fire Tests of Building Construction and Materials.

1.4 SUBMITTALS

A. Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

08 31 13 - 2

B. Submittal Drawings:

1. Show size, configuration, and fabrication and installation details.

C. Manufacturer's Literature and Data:

1. Description of each product.

2. Installation instructions.

D. Sustainable Construction Submittals:

1. Recycled Content: Identify post-consumer and pre-consumer recycled content percentage by weight.

1.5 DELIVERY

A. Deliver products in manufacturer's original sealed packaging.

B. Mark packaging, legibly. Indicate manufacturer's name or brand, type, // color, // production run number, and manufacture date.

C. Before installation, return or dispose of products within distorted, damaged, or opened packaging.

1.6 STORAGE AND HANDLING

A. Store products indoors in dry, weathertight facility.

B. Protect products from damage during handling and construction operations.

1.7 FIELD CONDITIONS

A. Field Measurements: Verify field conditions affecting access door fabrication and installation. Show field measurements on Submittal Drawings.

B. Coordinate field measurement and fabrication schedule to avoid delay.

1.8 WARRANTY

C. Construction Warranty: FAR clause 52.246-21, "Warranty of Construction."

PART 2 - PRODUCTS

2.1 MATERIALS

A. Stainless Steel: ASTM A666; Type 302 or Type 304.

2.2 PRODUCTS - GENERAL

A. Basis of Design: Best Access Doors FD2D, Acudor FW5050 Series or equivalent

B. Provide each product from one manufacturer.

2.3 ACCESS DOORS, FIRE-RATED

A. Door Construction:

08 31 13 - 3

1. Ceiling Access Door Construction: ASTM E119 or UL 263.

B. Label: Class B opening according to UL 10B or test by another nationally recognized laboratory. 1-1/2 hour fire-rated, with maximum temperature rise of 120 degrees C (216 degrees F).

C. Door Panel: Minimum 0.9 mm (0.0359 inch) thick stainless steel sheet, with mineral-fiber insulation core, insulated sandwich type construction.

D. Frame: Minimum 1.5 mm (0.0598 inch) thick steel sheet, depth and configuration to suit material and construction type where installed.

1. Frame Flange: Provide at units installed in concrete, masonry, or gypsum board.

2. Exposed Joints in Flange: Weld and grind smooth.

E. Provide automatic closing device.

F. Hinge: Continuous stainless steel hinge with stainless steel pin.

G. Lock: Self-latching, mortise type with provision for fitting flush a standard screw-in type lock cylinder.

1. Lock cylinder specified in Section 08 71 00, DOOR HARDWARE.

2. Latch release device operable from inside of door.

H. Anchors for Fire-Rated Access Doors: Comply with requirements of applicable fire test.

2.4 FABRICATION - GENERAL

A. Size: 36” x 48”

B. Component Fabrication: Straight, square, flat and in same plane where required.

1. Exposed Edges: Slightly rounded, without burrs, snags and sharp edges.

2. Exposed Welds: Continuous, ground smooth.

3. Welding: AWS D1.3/D1.3M.

C. Locks and Non-Continuous Hinges: Provide in numbers required to maintain alignment of door panel with frame. For fire-rated doors, provide hinges and locks as required by fire test.

D. Anchoring: Make provisions in frame for anchoring to adjacent construction. Provide anchors in size, number and location on four sides to secure access door to substrate. Provide anchors as required by fire test.

2.7 FINISHES

A. Stainless Steel Exposed Surfaces: NAAMM AMP 500; No. 4 polished finish.

2.8 ACCESSORIES

A. Fasteners: Type and size recommended by access door manufacturer, to suit application.

1. Stainless Steel Access Doors: Stainless steel fasteners.

PART 3 - EXECUTION

3.1 PREPARATION

A. Examine and verify substrate suitability for product installation.

08 31 13 - 4

1. Verify access door locations and sizes provide required maintenance access to installed building services components.

B. Protect existing construction and completed work from damage.

3.2 INSTALLATION - GENERAL

A. Install products according to manufacturer's instructions and approved submittal drawings.

B. When manufacturer's instructions deviate from specifications, submit proposed resolution for

Contracting Officer's Representative consideration.

C. Install access doors and panels permitting access to service valves, traps, dampers, cleanouts, and other mechanical, electrical and conveyor control items concealed in walls and partitions, and concealed above gypsum board and plaster ceilings.

D. Install fire rated access door according to NFPA 80.

E. Install fire-rated doors in fire-rated partitions and ceilings.

F. Install flush access panels in partitions and in gypsum board and plaster ceilings.

3.3 ACCESS DOOR AND FRAME INSTALLATION

A. Ceiling Installations: Install access doors parallel to ceiling deck.

B. Frames without Flanges: Install frame flush with surrounding finish surfaces.

C. Frames with Flanges: Overlap opening, with face uniformly spaced from finish surface.

D. Recessed Panel Access Doors: Install with face of surrounding materials flush with door panel installed finish.

E. Secure frames to adjacent construction with fasteners.

F. Install type, size and quantity of anchoring device suitable for material surrounding opening to maintain alignment, and resist displacement, during normal use of access door.

G. Field Painting Primed Access Doors: Comply with the requirements of Section 09 91 00, PAINTING.

3.4 ADJUSTMENT

A. Adjust hardware so door panel opens freely.

B. Adjust door when closed so door panel is centered in frame.

- - E N D - -