S02 ATTACHMENT 22--DRAWINGS 4 ARCHITECTURAL A106-A301
Drawings
ARCHITECTURAL
PAGES A106-A301
691-17-104WL
RETROFIT SEWER SYSTEM B500 1ST 5TH 6TH
FLOOR
A A
B B
C C
D D
E E
F F
G G
H H
J J
K K
L L
M M
N N
O O
P P
Q Q
R R
S S
'-0
'-6
'-0
'-0
'-0
'-0
'-6
'-0
'-0
'-0
'-6
'-0
'-0
'-0
'-0
'-6
'-0
19'-0" 11'-6" 18'-0" 52'-0" 70'-0" 23'-6" 12'-0" 80'-0" 12'-0" 23'-6" 18'-0" 52'-0" 48'-6" 18'-0" 15'-0" 19'-0"
'-0
'-6
'-0
'-0
'-0
'-0
'-6
'-0
'-0
'-0
'-6
'-0
'-0
'-0
'-0
'-6
'-0
19'-0" 11'-6" 18'-0" 52'-0" 52'-0" 18'-0" 23'-6" 12'-0" 80'-0" 12'-0" 23'-6" 18'-0" 52'-0" 48'-6" 18'-0" 15'-0" 19'-0"
MATCHLINE
FOR CONTINUATION SEE: 1/A-106B
MATCHLINE
FOR CONTINUATION SEE: 1/A-106D
MATCHLINE
FOR CONTINUATION SEE: 1/A-106A
MATCHLINE
FOR CONTINUATION SEE: 1/A-106A
MATCHLINE
FOR CONTINUATION SEE: 1/A-106C
MATCHLINE
FOR CONTINUATION SEE: 1/A-106C
MATCHLINE
FOR CONTINUATION SEE: 1/A-106B
MATCHLINE
FOR CONTINUATION SEE: 1/A-106D
M A
T C
H L
IN
E F
O R
C O
N T
IN
U
A T
IO
N
S E
E
/A
-1 B
M A
T C
H L
IN
E F
O R
C O
N T
IN
U
A T
IO
N
S E
-1 D
2 2
1 2 2
CHAPLAIN
SURGICAL ADMIN
DIRECTORS SUITE PHARMACY ADMIN
NURSING SERVICE ADMIN
NURSING SERVICE ADMIN
NURSING SERVICE ADMIN
MEDICAL REHAB BEDS - DIALYSIS
EDUCATION / TRAINING
SOCIAL WORK
DIRECTORS SUITE
PSYCHIATRY / NURSING ADMIN
2 2
= CHAPLAIN
DEPARTMENT NAMEPATTERN
LEGEND
= NURSING SERVICE ADMIN
= EDUCATION / TRAINING
= AREA OF WORK, REPLACE WASTE PIPE IN INTERSTITIAL
SPACE BELOW (SEE PLUMBING SHEETS).
= SURGICAL ADMIN
= MEDICAL REHAB BEDS -
DIALYSIS
= SOCIAL WORK
= DIRECTORS SUITE
= PHARMACY ADMINISTRATION
= PSYCHIATRY / NURSING
ADMIN
= COMMON SPACE, LOBBY, ETC.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION DOCUMENTS
SUBMISSION - ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Mechanical:
AREA D
B500 KEY PLAN
AREA B
AREA A
AREA C
35% SCHEMATIC DESIGN SUBMISSION 09/14/2017
65% DESIGN DEVELOPMENT SUBMISSION 10/11/2017
100% CONSTRUCTION DOCUMENTS SUBMISSION - ISSUED FOR CONSTRUCTION
11/01/2017
95% CONSTRUCTION DOCUMENTS - OWNER REVIEW
11/20/2017
B
IM
/6
-1
-1
W
L R e tr o fi t S e w e r
S y s te m B s t, th th
F L /6
-1
-1
W
L V
A G
L A
H C
S -R e tr o fi tS e w e r-
B .r v t
/2
/2
:4 :0
P
M
A-106
ARCHITECTURAL PLAN - SIXTH FLOOR -
COMPOSITE
TRIPLE C The A/E Group
4401 Atlantic Avenue, Suite 200
Long Beach, CA 90807
(562) 452-7175
Mat Perkins
P2S Engineering
5000 East Spring Street, 8th Floor
Long Beach, CA 90815
(562) 497-2999
Mikhail Fuks, P.E.
RETROFIT SEWER SYSTEM B500
FIRST, FIFTH & SIXTH FLOORS
11301 Wilshire Blvd., Los Angeles, CA 90073
691-17-104WL
B500
NOVEMBER 20, 2017 M. PERKINS K. LUKE
3/64" = 1'-0"
ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE
A. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR
SMOKE RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN
WORK AREA. PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE
AND FULL HEIGHT WALLS SHALL BE CAULKED AIRTIGHT TO THE
ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED FIRE PROOF
CAULKING MATERIAL. SEE PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
B. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND
CONDUIT PIPING WITH STRUCTURAL, MECHANICAL, AND
ELECTRICAL SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS
TO AVOID CONFLICTS AND TO MAINTAIN REQUIRED EQUIPMENT
ACCESS AND SERVICEABILITY.
C. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD
VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER
FROM THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN
ADVANCE THE LOCATION AND CONDITION OF THOSE EXISTING
SYSTEMS SHOWN TO BE MODIFIED OR REMOVED. CONTRACTOR TO
NOTIFY ARCHITECT SHOULD CONDITIONS BE FOUND TO DIFFER
SIGNIFICANTLY FROM CONSTRUCTION DOCUMENTS.
D. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED
AT CONNECTIONS BETWEEN ALL DISSIMILAR METALS.
E. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS
REQUIRED TO COMPLETE THIS PROJECT, THE CONTRACTOR SHALL
PATCH AND PAINT AND RETURN TO MATCH EXISTING CONDITIONS
AND FINISHES.
F. CONTRACTOR TO PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED
EXTERIOR PIPE PENETRATIONS AND SEAL COMPLETELY.
G. PHASING SCHEDULE SHALL BE BASED UPON MINIMIZING
DISRUPTIONS TO EXISTING BUILDING OPERATION.
H. CONTRACTOR SHALL PROVIDE BARRIERS AS REQUIRED TO
PREVENT CONTAMINATION FROM SEWAGE SPILLS AND WASTE
MATTER. STATIC-FREE DUST BARRIERS FORMED WITH PLASTIC
SHEETS SHALL BE PROVIDED (USING FACILE OR GRIFFOLYN WITH
FIRE RATING) WITH THE APPROVAL OF THE COR.
I. UNLESS OTHERWISE NOTED, WASTE AND VENT PIPING IS SLOPED
AT 1/4" PER 100' (2%).
J. IN THE EVENT THE CONTRACTOR ENCOUNTERS ASBESTOS
CONTAINING MATERIAL, ALL WORK WITHIN THE AFFECTED AREA
SHALL IMMEDIATELY STOP AND THE CONTRACTOR SHALL NOTIFY
THE COR. NO WORK MAY RESUME WITHOUT COR'S WRITTEN
PERMISSION.
K. ABANDON OR REMOVE DISCONNECTED PORTIONS OF EXISTING
PIPING AS NECESSARY TO MAKE NEW CONSTRUCTION POSSIBLE.
L. THE SEISMIC BRACING AND ANCHORAGE OF PIPING SHALL BE IN
ACCORDANCE WITH GUIDLINES FOR SEISMIC RESTRAINTS OF
PLUMBING SYSTEMS PUBLISHED BY SMACNA.
M. SEISMIC DESIGN REQUIREMENTS OF THE PROJECT SHALL
CONFORM TO VA PLUMBING AND SEISMIC DESIGN MANUALS, H-18-8.
N. FOR THE PROJECT PHASES AND STAGES, ALL NEW REPLACEMENT
PIPING SHALL BE INSTALLED WITH THE MOST CURRENT
REQUIREMENT FOR SEISMIC RESTRAINTS.
O. ALL WORK ON SANITARY SEWER AND CHEMICAL WASTE AND VENT
PIPING SHALL BE IN ACCORDANCE WITH VA SPECIFICATIONS: 22 05
11, 22 08 00, 22 13 00 AND 22 66 00 AND THE VA PLUMBING DESIGN
MANUAL, 2014 OR MOST CURRENT VERSION.
GENERAL SHEET NOTES
1 REFER TO AREA PLANS FOR EXISTING PLUMBING FIXTURE TYPES
2 WASTE AND VENT PIPING TO BE REPLACED, BELOW. SEE PLUMBING PLANS.
KEYNOTES
Revisions: Date: Expires 6.30.16Expires: 6/30/18
/20
/17
A
B
C
D
E
F
7891112 10
P-92WCF
P-2
P-2 P-66D P-66D
P-7
P-7
P-7
P-7
P-69A
P-92WCF
P-7
P-66 WCL
P-2 WCF
P-66D
P-66D
P-66D
P-2
P-2
P-7
P-7
B.1
7.1
9.1
9.29.259.39.411.1
D.1
D.2
E.1
E.2
X.1X.2X.3X.4X.5X.7 X.6X.10 X.9 X.8
'-0
9'
-0
2' -6
'-0
'-0
5'
-6
'-6
'-0
5' -0
'-0
MATCHLINE
FOR CONTINUATION SEE: 1/A-106B
MATCHLINE
FOR CONTINUATION SEE: 1/A-106D
6'-6" 3'-6" 10'-0" 3'-6" 8'-8" 2'-0"1'-4" 22'-6" 8'-6" 6'-6" 2'-6" 7'-0" 6'-4" 9'-8" 17'-0" 1'-4"2'-0" 8'-8" 3'-6" 10'-0" 3'-6" 6'-6"
DIRECTORS SUITE
PHARMACY ADMIN
MEDICAL REHAB BEDS - DIALYSIS
6034G6034G
6034F6034F
6034B6034B
6034A6034A
6034C6034C
6034D6034D 6034E6034E
60346034
6034H6034H6034J6034J
60036003
60046004
60056005
60066006
6007600760086008
60096009 60106010
60116011
60126012
6013601360146014
60156015
60166016
60176017
60186018
60196019
60206020
60216021
60226022 60236023 60246024 60256025 60266026
60296029 60306030 60316031 60326032
60336033
6034K6034K60356035
60366036
60376037
60386038 60396039
60406040
60416041
60426042
6005A6005A
6005B6005B6006A6006A
6006D6006D
6006F6006F
6005D6005D
6023A6023A
6037A6037A
6042A6042A 6042B6042B 6042C6042C 6042D6042D
6042E6042E
60286028
ELEV.ELEV.
6006G6006G
6042F6042F6042G6042G
CN 6-6CN 6-6
CN 6-3CN 6-3
CN 6-1ACN 6-1A
1615A1615A1615B1615B
6006B6006B
6006E6006E
6005C6005C
6005E6005E
CN 6-4CN 6-4
13131414
P-91
P-7 P-7
P-7
P-7
P-7
= CHAPLAIN
DEPARTMENT NAMEPATTERN
LEGEND
= NURSING SERVICE ADMIN
= EDUCATION / TRAINING
= AREA OF WORK, REPLACE WASTE PIPE IN INTERSTITIAL
SPACE BELOW (SEE PLUMBING SHEETS).
= SURGICAL ADMIN
= MEDICAL REHAB BEDS -
DIALYSIS
= SOCIAL WORK
= DIRECTORS SUITE
= PHARMACY ADMINISTRATION
= PSYCHIATRY / NURSING
ADMIN
= COMMON SPACE, LOBBY, ETC.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION DOCUMENTS
SUBMISSION - ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Mechanical:
B500 KEY PLAN
AREA A
35% SCHEMATIC DESIGN SUBMISSION 09/14/2017
65% DESIGN DEVELOPMENT SUBMISSION 10/11/2017
100% CONSTRUCTION DOCUMENTS SUBMISSION - ISSUED FOR CONSTRUCTION
11/01/2017
95% CONSTRUCTION DOCUMENTS - OWNER REVIEW
11/20/2017
B
IM
/6
-1
-1
W
L R e tr o fi t S e w e r
S y s te m B s t, th th
F L /6
-1
-1
W
L V
A G
L A
H C
S -R e tr o fi tS e w e r-
B .r v t
/2
/2
:4 :0
P
M
A-106A
ARCHITECTURAL PLAN - SIXTH FLOOR - AREA
A
TRIPLE C The A/E Group
4401 Atlantic Avenue, Suite 200
Long Beach, CA 90807
(562) 452-7175
Mat Perkins
P2S Engineering
5000 East Spring Street, 8th Floor
Long Beach, CA 90815
(562) 497-2999
Mikhail Fuks, P.E.
RETROFIT SEWER SYSTEM B500
FIRST, FIFTH & SIXTH FLOORS
11301 Wilshire Blvd., Los Angeles, CA 90073
691-17-104WL
B500
NOVEMBER 20, 2017 M. PERKINS K. LUKE
1/8" = 1'-0"
ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A
A. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR
SMOKE RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN
WORK AREA. PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE
AND FULL HEIGHT WALLS SHALL BE CAULKED AIRTIGHT TO THE
ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED FIRE PROOF
CAULKING MATERIAL. SEE PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
B. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND
CONDUIT PIPING WITH STRUCTURAL, MECHANICAL, AND
ELECTRICAL SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS
TO AVOID CONFLICTS AND TO MAINTAIN REQUIRED EQUIPMENT
ACCESS AND SERVICEABILITY.
C. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD
VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER
FROM THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN
ADVANCE THE LOCATION AND CONDITION OF THOSE EXISTING
SYSTEMS SHOWN TO BE MODIFIED OR REMOVED. CONTRACTOR TO
NOTIFY ARCHITECT SHOULD CONDITIONS BE FOUND TO DIFFER
SIGNIFICANTLY FROM CONSTRUCTION DOCUMENTS.
D. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED
AT CONNECTIONS BETWEEN ALL DISSIMILAR METALS.
E. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS
REQUIRED TO COMPLETE THIS PROJECT, THE CONTRACTOR SHALL
PATCH AND PAINT AND RETURN TO MATCH EXISTING CONDITIONS
AND FINISHES.
F. CONTRACTOR TO PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED
EXTERIOR PIPE PENETRATIONS AND SEAL COMPLETELY.
G. PHASING SCHEDULE SHALL BE BASED UPON MINIMIZING
DISRUPTIONS TO EXISTING BUILDING OPERATION.
H. CONTRACTOR SHALL PROVIDE BARRIERS AS REQUIRED TO
PREVENT CONTAMINATION FROM SEWAGE SPILLS AND WASTE
MATTER. STATIC-FREE DUST BARRIERS FORMED WITH PLASTIC
SHEETS SHALL BE PROVIDED (USING FACILE OR GRIFFOLYN WITH
FIRE RATING) WITH THE APPROVAL OF THE COR.
I. UNLESS OTHERWISE NOTED, WASTE AND VENT PIPING IS SLOPED
AT 1/4" PER 100' (2%).
J. IN THE EVENT THE CONTRACTOR ENCOUNTERS ASBESTOS
CONTAINING MATERIAL, ALL WORK WITHIN THE AFFECTED AREA
SHALL IMMEDIATELY STOP AND THE CONTRACTOR SHALL NOTIFY
THE COR. NO WORK MAY RESUME WITHOUT COR'S WRITTEN
PERMISSION.
K. ABANDON OR REMOVE DISCONNECTED PORTIONS OF EXISTING
PIPING AS NECESSARY TO MAKE NEW CONSTRUCTION POSSIBLE.
L. THE SEISMIC BRACING AND ANCHORAGE OF PIPING SHALL BE IN
ACCORDANCE WITH GUIDLINES FOR SEISMIC RESTRAINTS OF
PLUMBING SYSTEMS PUBLISHED BY SMACNA.
M. SEISMIC DESIGN REQUIREMENTS OF THE PROJECT SHALL
CONFORM TO VA PLUMBING AND SEISMIC DESIGN MANUALS, H-18-8.
N. FOR THE PROJECT PHASES AND STAGES, ALL NEW REPLACEMENT
PIPING SHALL BE INSTALLED WITH THE MOST CURRENT
REQUIREMENT FOR SEISMIC RESTRAINTS.
O. ALL WORK ON SANITARY SEWER AND CHEMICAL WASTE AND VENT
PIPING SHALL BE IN ACCORDANCE WITH VA SPECIFICATIONS: 22 05
11, 22 08 00, 22 13 00 AND 22 66 00 AND THE VA PLUMBING DESIGN
MANUAL, 2014 OR MOST CURRENT VERSION.
GENERAL SHEET NOTES
1 REFER TO PLUMBING FIXTURE SHEDULE ON P - 600 SERIES SHEETS FOR
EXISTING PLUMBING FIXTURE TYPES
2 WASTE AND VENT PIPING TO BE REPLACED, BELOW. SEE PLUMBING PLANS.
KEYNOTES
Revisions: Date: Expires 6.30.16Expires: 6/30/18
G
23456789
H
J
K
L
M
P-66D
P-66DP-91
P-2
P-2
P-66 WCL P-66 WCL
P-2 WCF P-2 WCF
P-14C
P-66D
P-66D
P-66D
P-66D
P-66D
P-66D
P-91
P-91
P-2
P-2
P-2
P-7
P-92WR
P-66D
P-66D
P-2
P-2
P-7
P-7
2.13.13.24.25.17.19.19.29.25
G.1
J.1
J.2
J.3
J.4
L.1
4.1X.1X.2X.3X.4X.5
X.A
X.B
X.C
X.D
X.E
X.F
X.G
X.H
X.J
X.K
J.2.1
X.6
6' -6
3'
-6
'-0
3'
-6
8' -8
2'
-0
1' -4
'-0
2' -0
3'
-8
2"
'-2
8' -4
5'
-8
'-0
1'
-4
2' -0
8'
-8
3' -6
'-0
3' -6
6'
-6
MATCHLINE
FOR CONTINUATION SEE: 1/A-106A
M A
T C
H L
IN
E F
O R
C O
N T
IN
U
A T
IO
N
S E
-1 D
2'-6" 7'-0" 6'-4" 9'-8" 17'-0" 1'-4"2'-0" 8'-8" 3'-6" 10'-0" 3'-6" 6'-6" 18'-0" 25'-0" 27'-0" 22'-6" 3'-6" 22'-6" 6'-7" 9'-8" 1'-9" 6'-0" 9'-0" 19'-0"
T-S4
P-92WCF
T-22C
P-92WCF
MATCHLINE
FOR CONTINUATION SEE: 1/A-106C
NURSING SERVICE ADMIN
NURSING SERVICE ADMIN
EDUCATION / TRAINING
SOCIAL WORK
64006400
62026202 62036203
6204A6204A
62056205
62066206
62076207
62086208 62096209 62116211
6212621262136213
6214B6214B
62156215
62166216 62176217
62186218
62196219
62206220
62216221
62226222
62236223
62246224
62256225 62266226 62276227 62286228 62296229 62306230
62316231
62326232
62336233
62346234
62356235
62366236
62376237
62386238
62396239624062406241624162426242
62436243
62456245
62466246
62476247
62496249
62506250
6251B6251B
62526252
6251M6251M
6249B6249B
62536253
60436043
6045604562006200
6251D6251D
CE 6-8CE 6-8
CE 6-7ACE 6-7A
CE 6-7CE 6-7CE 6-5CE 6-5
CE 6-6CE 6-6
62486248
6251A6251A
6251C6251C
6251E6251E 6251F6251F 6251G6251G 6251H6251H 6251I6251I
6251J6251J6251K6251K6251L6251L62516251
6215D6215D
ELEV.ELEV.
62046204
621062106210B6210B
6214A6214A
6214C6214C 6215B6215B
6215C6215C
ELEV.ELEV.
6VSH76VSH7
6251C6251C
CE 6-2ACE 6-2A
CE 6-2BCE 6-2B
6VSH136VSH13
11111111
= CHAPLAIN
DEPARTMENT NAMEPATTERN
LEGEND
= NURSING SERVICE ADMIN
= EDUCATION / TRAINING
= AREA OF WORK, REPLACE WASTE PIPE IN INTERSTITIAL
SPACE BELOW (SEE PLUMBING SHEETS).
= SURGICAL ADMIN
= MEDICAL REHAB BEDS -
DIALYSIS
= SOCIAL WORK
= DIRECTORS SUITE
= PHARMACY ADMINISTRATION
= PSYCHIATRY / NURSING
ADMIN
= COMMON SPACE, LOBBY, ETC.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION DOCUMENTS
SUBMISSION - ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Mechanical:
B500 KEY PLAN
AREA B
35% SCHEMATIC DESIGN SUBMISSION 09/14/2017
65% DESIGN DEVELOPMENT SUBMISSION 10/11/2017
100% CONSTRUCTION DOCUMENTS SUBMISSION - ISSUED FOR CONSTRUCTION
11/01/2017
95% CONSTRUCTION DOCUMENTS - OWNER REVIEW
11/20/2017
B
IM
/6
-1
-1
W
L R e tr o fi t S e w e r
S y s te m B s t, th th
F L /6
-1
-1
W
L V
A G
L A
H C
S -R e tr o fi tS e w e r-
B .r v t
/2
/2
:4 :1
P
M
A-106B
ARCHITECTURAL PLAN - SIXTH FLOOR - AREA
B
TRIPLE C The A/E Group
4401 Atlantic Avenue, Suite 200
Long Beach, CA 90807
(562) 452-7175
Mat Perkins
P2S Engineering
5000 East Spring Street, 8th Floor
Long Beach, CA 90815
(562) 497-2999
Mikhail Fuks, P.E.
RETROFIT SEWER SYSTEM B500
FIRST, FIFTH & SIXTH FLOORS
11301 Wilshire Blvd., Los Angeles, CA 90073
691-17-104WL
B500
NOVEMBER 20, 2017 M. PERKINS K. LUKE
1/8" = 1'-0"
ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B
A. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR
SMOKE RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN
WORK AREA. PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE
AND FULL HEIGHT WALLS SHALL BE CAULKED AIRTIGHT TO THE
ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED FIRE PROOF
CAULKING MATERIAL. SEE PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
B. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND
CONDUIT PIPING WITH STRUCTURAL, MECHANICAL, AND
ELECTRICAL SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS
TO AVOID CONFLICTS AND TO MAINTAIN REQUIRED EQUIPMENT
ACCESS AND SERVICEABILITY.
C. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD
VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER
FROM THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN
ADVANCE THE LOCATION AND CONDITION OF THOSE EXISTING
SYSTEMS SHOWN TO BE MODIFIED OR REMOVED. CONTRACTOR TO
NOTIFY ARCHITECT SHOULD CONDITIONS BE FOUND TO DIFFER
SIGNIFICANTLY FROM CONSTRUCTION DOCUMENTS.
D. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED
AT CONNECTIONS BETWEEN ALL DISSIMILAR METALS.
E. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS
REQUIRED TO COMPLETE THIS PROJECT, THE CONTRACTOR SHALL
PATCH AND PAINT AND RETURN TO MATCH EXISTING CONDITIONS
AND FINISHES.
F. CONTRACTOR TO PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED
EXTERIOR PIPE PENETRATIONS AND SEAL COMPLETELY.
G. PHASING SCHEDULE SHALL BE BASED UPON MINIMIZING
DISRUPTIONS TO EXISTING BUILDING OPERATION.
H. CONTRACTOR SHALL PROVIDE BARRIERS AS REQUIRED TO
PREVENT CONTAMINATION FROM SEWAGE SPILLS AND WASTE
MATTER. STATIC-FREE DUST BARRIERS FORMED WITH PLASTIC
SHEETS SHALL BE PROVIDED (USING FACILE OR GRIFFOLYN WITH
FIRE RATING) WITH THE APPROVAL OF THE COR.
I. UNLESS OTHERWISE NOTED, WASTE AND VENT PIPING IS SLOPED
AT 1/4" PER 100' (2%).
J. IN THE EVENT THE CONTRACTOR ENCOUNTERS ASBESTOS
CONTAINING MATERIAL, ALL WORK WITHIN THE AFFECTED AREA
SHALL IMMEDIATELY STOP AND THE CONTRACTOR SHALL NOTIFY
THE COR. NO WORK MAY RESUME WITHOUT COR'S WRITTEN
PERMISSION.
K. ABANDON OR REMOVE DISCONNECTED PORTIONS OF EXISTING
PIPING AS NECESSARY TO MAKE NEW CONSTRUCTION POSSIBLE.
L. THE SEISMIC BRACING AND ANCHORAGE OF PIPING SHALL BE IN
ACCORDANCE WITH GUIDLINES FOR SEISMIC RESTRAINTS OF
PLUMBING SYSTEMS PUBLISHED BY SMACNA.
M. SEISMIC DESIGN REQUIREMENTS OF THE PROJECT SHALL
CONFORM TO VA PLUMBING AND SEISMIC DESIGN MANUALS, H-18-8.
N. FOR THE PROJECT PHASES AND STAGES, ALL NEW REPLACEMENT
PIPING SHALL BE INSTALLED WITH THE MOST CURRENT
REQUIREMENT FOR SEISMIC RESTRAINTS.
O. ALL WORK ON SANITARY SEWER AND CHEMICAL WASTE AND VENT
PIPING SHALL BE IN ACCORDANCE WITH VA SPECIFICATIONS: 22 05
11, 22 08 00, 22 13 00 AND 22 66 00 AND THE VA PLUMBING DESIGN
MANUAL, 2014 OR MOST CURRENT VERSION.
GENERAL SHEET NOTES
1 REFER TO PLUMBING FIXTURE SHEDULE ON P - 600 SERIES SHEETS FOR
EXISTING PLUMBING FIXTURE TYPES
2 WASTE AND VENT PIPING TO BE REPLACED, BELOW. SEE PLUMBING PLANS.
KEYNOTES
Revisions: Date: Expires 6.30.16Expires: 6/30/18
7891112 10
N
O
P
Q
R
S
P-66
P-2
P-2 WCF
P-2 WCF
P-2 P-91
P-91
P-66D
P-66 WCL
P-66 WCL
P-66D
7.19.19.29.259.39.411.1
N.2
N.4
N.7
O.1
Q.1
X.1X.2X.3X.4X.5X.7 X.6
O.2
N.3
X.10 X.9 X.8
6'-6" 3'-6" 10'-0" 3'-6" 8'-8" 2'-0"1'-4" 22'-6" 8'-6" 6'-6" 2'-6" 7'-0" 6'-4" 9'-8" 17'-0" 1'-4"2'-0" 8'-8" 3'-6" 10'-0" 3'-6" 6'-6"
'-6
1'
-6
4' -0
'-5
3' -7
'-6
'-9
'-9
'-0
2'
-6
9' -0
'-0
MATCHLINE
FOR CONTINUATION SEE: 1/A-106B
MATCHLINE
FOR CONTINUATION SEE: 1/A-106D
P-92WCF
NURSING SERVICE ADMIN
PSYCHIATRY / NURSING ADMIN
6404J6404J
64056405
64066406
64076407
64086408
64096409
64106410
64116411
64126412
64136413
64146414
CS 6-5CS 6-5
6417641764186418
64196419
6420A6420A
6421642164226422
6423642364246424
64256425 64266426
64286428
64036403 6404H6404H
6404C6404C6404B6404B6404A6404A
64016401
64026402
6429B6429B
6426A6426A
6427B6427B
6429F6429F
6429G6429G
6429H6429H S606S606
6429M6429M
6429J6429J
6429K6429K 6429L6429L
6416A6416A
6416B6416B6416C6416C
6423A6423A
6424A6424A
CS 6-12CS 6-12
CS 6-14CS 6-14
64206420
6416D6416D
6416E6416E
CS 6-7CS 6-7
CS 6-8CS 6-8
CS 6-9CS 6-9
CS 6-3CS 6-3
CS 6-1CS 6-1
6404D6404D 6404E6404E 6404F6404F
64046404
6404I6404I
ELEV.ELEV.
6404G6404G
64276427
6429A6429A6429C6429C6429D6429D6429E6429E
CS 6-4CS 6-4CS 6-13CS 6-13
99 1010
DIRECTORS SUITE
= CHAPLAIN
DEPARTMENT NAMEPATTERN
LEGEND
= NURSING SERVICE ADMIN
= EDUCATION / TRAINING
= AREA OF WORK, REPLACE WASTE PIPE IN INTERSTITIAL
SPACE BELOW (SEE PLUMBING SHEETS).
= SURGICAL ADMIN
= MEDICAL REHAB BEDS -
DIALYSIS
= SOCIAL WORK
= DIRECTORS SUITE
= PHARMACY ADMINISTRATION
= PSYCHIATRY / NURSING
ADMIN
= COMMON SPACE, LOBBY, ETC.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION DOCUMENTS
SUBMISSION - ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Mechanical:
B500 KEY PLAN
AREA C
35% SCHEMATIC DESIGN SUBMISSION 09/14/2017
65% DESIGN DEVELOPMENT SUBMISSION 10/11/2017
100% CONSTRUCTION DOCUMENTS SUBMISSION - ISSUED FOR CONSTRUCTION
11/01/2017
95% CONSTRUCTION DOCUMENTS - OWNER REVIEW
11/20/2017
B
IM
/6
-1
-1
W
L R e tr o fi t S e w e r
S y s te m B s t, th th
F L /6
-1
-1
W
L V
A G
L A
H C
S -R e tr o fi tS e w e r-
B .r v t
/2
/2
:4 :1
P
M
A-106C
ARCHITECTURAL PLAN - SIXTH FLOOR - AREA
C
TRIPLE C The A/E Group
4401 Atlantic Avenue, Suite 200
Long Beach, CA 90807
(562) 452-7175
Mat Perkins
P2S Engineering
5000 East Spring Street, 8th Floor
Long Beach, CA 90815
(562) 497-2999
Mikhail Fuks, P.E.
RETROFIT SEWER SYSTEM B500
FIRST, FIFTH & SIXTH FLOORS
11301 Wilshire Blvd., Los Angeles, CA 90073
691-17-104WL
B500
NOVEMBER 20, 2017 M. PERKINS K. LUKE
1/8" = 1'-0"
ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C
A. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR
SMOKE RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN
WORK AREA. PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE
AND FULL HEIGHT WALLS SHALL BE CAULKED AIRTIGHT TO THE
ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED FIRE PROOF
CAULKING MATERIAL. SEE PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
B. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND
CONDUIT PIPING WITH STRUCTURAL, MECHANICAL, AND
ELECTRICAL SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS
TO AVOID CONFLICTS AND TO MAINTAIN REQUIRED EQUIPMENT
ACCESS AND SERVICEABILITY.
C. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD
VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER
FROM THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN
ADVANCE THE LOCATION AND CONDITION OF THOSE EXISTING
SYSTEMS SHOWN TO BE MODIFIED OR REMOVED. CONTRACTOR TO
NOTIFY ARCHITECT SHOULD CONDITIONS BE FOUND TO DIFFER
SIGNIFICANTLY FROM CONSTRUCTION DOCUMENTS.
D. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED
AT CONNECTIONS BETWEEN ALL DISSIMILAR METALS.
E. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS
REQUIRED TO COMPLETE THIS PROJECT, THE CONTRACTOR SHALL
PATCH AND PAINT AND RETURN TO MATCH EXISTING CONDITIONS
AND FINISHES.
F. CONTRACTOR TO PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED
EXTERIOR PIPE PENETRATIONS AND SEAL COMPLETELY.
G. PHASING SCHEDULE SHALL BE BASED UPON MINIMIZING
DISRUPTIONS TO EXISTING BUILDING OPERATION.
H. CONTRACTOR SHALL PROVIDE BARRIERS AS REQUIRED TO
PREVENT CONTAMINATION FROM SEWAGE SPILLS AND WASTE
MATTER. STATIC-FREE DUST BARRIERS FORMED WITH PLASTIC
SHEETS SHALL BE PROVIDED (USING FACILE OR GRIFFOLYN WITH
FIRE RATING) WITH THE APPROVAL OF THE COR.
I. UNLESS OTHERWISE NOTED, WASTE AND VENT PIPING IS SLOPED
AT 1/4" PER 100' (2%).
J. IN THE EVENT THE CONTRACTOR ENCOUNTERS ASBESTOS
CONTAINING MATERIAL, ALL WORK WITHIN THE AFFECTED AREA
SHALL IMMEDIATELY STOP AND THE CONTRACTOR SHALL NOTIFY
THE COR. NO WORK MAY RESUME WITHOUT COR'S WRITTEN
PERMISSION.
K. ABANDON OR REMOVE DISCONNECTED PORTIONS OF EXISTING
PIPING AS NECESSARY TO MAKE NEW CONSTRUCTION POSSIBLE.
L. THE SEISMIC BRACING AND ANCHORAGE OF PIPING SHALL BE IN
ACCORDANCE WITH GUIDLINES FOR SEISMIC RESTRAINTS OF
PLUMBING SYSTEMS PUBLISHED BY SMACNA.
M. SEISMIC DESIGN REQUIREMENTS OF THE PROJECT SHALL
CONFORM TO VA PLUMBING AND SEISMIC DESIGN MANUALS, H-18-8.
N. FOR THE PROJECT PHASES AND STAGES, ALL NEW REPLACEMENT
PIPING SHALL BE INSTALLED WITH THE MOST CURRENT
REQUIREMENT FOR SEISMIC RESTRAINTS.
O. ALL WORK ON SANITARY SEWER AND CHEMICAL WASTE AND VENT
PIPING SHALL BE IN ACCORDANCE WITH VA SPECIFICATIONS: 22 05
11, 22 08 00, 22 13 00 AND 22 66 00 AND THE VA PLUMBING DESIGN
MANUAL, 2014 OR MOST CURRENT VERSION.
GENERAL SHEET NOTES
1 REFER TO PLUMBING FIXTURE SHEDULE ON P - 600 SERIES SHEETS FOR
EXISTING PLUMBING FIXTURE TYPES
2 WASTE AND VENT PIPING TO BE REPLACED, BELOW. SEE PLUMBING PLANS.
KEYNOTES
Revisions: Date: Expires 6.30.16Expires: 6/30/18
G
1112 10
H
J
K
L
M
131415161718
P-66D
P-66D
P-2
P-2
P-2 WCF
P-66 WCL
P-2
P-2P-66D
P-2
P-66D
P-14C
P-2 P-2
P-7
9.39.411.113.314.116.1
G.1
J.1
J.2
J.3
J.4
L.1
X.A
X.B
X.C
X.D
X.E
X.F
X.G
X.H
X.J
X.K
J.2.1
X.7 X.613.113.213.414.2 X.10 X.9 X.8
19'-0" 9'-0" 2'-6" 18'-0" 10'-2" 19'-4" 22'-6" 9'-9" 17'-3" 4'-0" 11'-0" 10'-0" 18'-0" 6'-6" 3'-6" 10'-0" 3'-6" 8'-8" 2'-0"1'-4" 22'-6" 8'-6" 6'-6"
6' -6
3'
-6
'-0
3'
-6
8' -8
2'
-0
1' -4
'-0
2' -0
3'
-8
2"
'-2
8' -4
5'
-8
'-0
1'
-4
2' -0
8'
-8
3' -6
'-0
3' -6
6'
-6
MATCHLINE
FOR CONTINUATION SEE: 1/A-106C
M A
T C
H L
IN
E F
O R
C O
N T
IN
U
A T
IO
N
S E
-1 B
P-92WCF
P-92WCF
MATCHLINE
FOR CONTINUATION SEE: 1/A-106A
CHAPLAIN
SURGICAL ADMIN
CS 6-1CS 6-1
60026002
CS 6-13CS 6-13
64306430
6VSH216VSH21
6001A6001A
6657B6657B
6VSH236VSH23
66026602
6603A6603A
66046604
66056605
66076607
66086608
6609660966106610661166116612A6612A
6612B6612B
66146614
6616B6616B
6617661766186618661966196620662066216621
66226622
66236623 66246624
66256625
66266626
66276627
6628B6628B
66296629663066306631663166326632
6633663366346634663566356636663666376637
66386638 66396639 66406640 66416641 66426642 66436643
66446644 66456645
66466646 66476647 66486648
66496649
66506650
66516651
66526652 66546654 66556655 66566656
66576657
CW 6-8CW 6-8
66596659
66606660
66616661
66626662
6663A6663A
66656665
66666666
6601A6601A
CW-6-2BCW-6-2B
6429K6429K 6429L6429L
60006000
60026002
60016001
66126612 6608C6608C
66066606
6606B6606B
ELEV.ELEV.
66136613
66006600
66016601
66166616
CW 6-16CW 6-16
CW 6-9CW 6-9
CW 6-14CW 6-14 CW 6-3ACW 6-3A
CW -6-3CW -6-3CW -6-4CW -6-4
CW -6-5CW -6-5
CW -6-6CW -6-6
66636663
CW 6-12CW 6-12
CW 6-10CW 6-10
6628A6628A
66286628
CW 6-18CW 6-18
P-14C
ELEVATOR ELEVATOR ELEVATOR ELEVATOR
ELEVATOR ELEVATOR ELEVATOR
ELEVATOR ELEVATOR ELEVATOR
= CHAPLAIN
DEPARTMENT NAMEPATTERN
LEGEND
= NURSING SERVICE ADMIN
= EDUCATION / TRAINING
= AREA OF WORK, REPLACE WASTE PIPE IN INTERSTITIAL
SPACE BELOW (SEE PLUMBING SHEETS).
= SURGICAL ADMIN
= MEDICAL REHAB BEDS -
DIALYSIS
= SOCIAL WORK
= DIRECTORS SUITE
= PHARMACY ADMINISTRATION
= PSYCHIATRY / NURSING
ADMIN
= COMMON SPACE, LOBBY, ETC.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION DOCUMENTS
SUBMISSION - ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Mechanical:
AREA D
B500 KEY PLAN
35% SCHEMATIC DESIGN SUBMISSION 09/14/2017
65% DESIGN DEVELOPMENT SUBMISSION 10/11/2017
100% CONSTRUCTION DOCUMENTS SUBMISSION - ISSUED FOR CONSTRUCTION
11/01/2017
95% CONSTRUCTION DOCUMENTS - OWNER REVIEW
11/20/2017
B
IM
/6
-1
-1
W
L R e tr o fi t S e w e r
S y s te m B s t, th th
F L /6
-1
-1
W
L V
A G
L A
H C
S -R e tr o fi tS e w e r-
B .r v t
/2
/2
:4 :2
P
M
A-106D
ARCHITECTURAL PLAN - SIXTH FLOOR - AREA
D
TRIPLE C The A/E Group
4401 Atlantic Avenue, Suite 200
Long Beach, CA 90807
(562) 452-7175
Mat Perkins
P2S Engineering
5000 East Spring Street, 8th Floor
Long Beach, CA 90815
(562) 497-2999
Mikhail Fuks, P.E.
RETROFIT SEWER SYSTEM B500
FIRST, FIFTH & SIXTH FLOORS
11301 Wilshire Blvd., Los Angeles, CA 90073
691-17-104WL
B500
NOVEMBER 20, 2017 M. PERKINS K. LUKE
1/8" = 1'-0"
ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D
A. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR
SMOKE RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN
WORK AREA. PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE
AND FULL HEIGHT WALLS SHALL BE CAULKED AIRTIGHT TO THE
ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED FIRE PROOF
CAULKING MATERIAL. SEE PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
B. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND
CONDUIT PIPING WITH STRUCTURAL, MECHANICAL, AND
ELECTRICAL SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS
TO AVOID CONFLICTS AND TO MAINTAIN REQUIRED EQUIPMENT
ACCESS AND SERVICEABILITY.
C. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD
VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER
FROM THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN
ADVANCE THE LOCATION AND CONDITION OF THOSE EXISTING
SYSTEMS SHOWN TO BE MODIFIED OR REMOVED. CONTRACTOR TO
NOTIFY ARCHITECT SHOULD CONDITIONS BE FOUND TO DIFFER
SIGNIFICANTLY FROM CONSTRUCTION DOCUMENTS.
D. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED
AT CONNECTIONS BETWEEN ALL DISSIMILAR METALS.
E. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS
REQUIRED TO COMPLETE THIS PROJECT, THE CONTRACTOR SHALL
PATCH AND PAINT AND RETURN TO MATCH EXISTING CONDITIONS
AND FINISHES.
F. CONTRACTOR TO PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED
EXTERIOR PIPE PENETRATIONS AND SEAL COMPLETELY.
G. PHASING SCHEDULE SHALL BE BASED UPON MINIMIZING
DISRUPTIONS TO EXISTING BUILDING OPERATION.
H. CONTRACTOR SHALL PROVIDE BARRIERS AS REQUIRED TO
PREVENT CONTAMINATION FROM SEWAGE SPILLS AND WASTE
MATTER. STATIC-FREE DUST BARRIERS FORMED WITH PLASTIC
SHEETS SHALL BE PROVIDED (USING FACILE OR GRIFFOLYN WITH
FIRE RATING) WITH THE APPROVAL OF THE COR.
I. UNLESS OTHERWISE NOTED, WASTE AND VENT PIPING IS SLOPED
AT 1/4" PER 100' (2%).
J. IN THE EVENT THE CONTRACTOR ENCOUNTERS ASBESTOS
CONTAINING MATERIAL, ALL WORK WITHIN THE AFFECTED AREA
SHALL IMMEDIATELY STOP AND THE CONTRACTOR SHALL NOTIFY
THE COR. NO WORK MAY RESUME WITHOUT COR'S WRITTEN
PERMISSION.
K. ABANDON OR REMOVE DISCONNECTED PORTIONS OF EXISTING
PIPING AS NECESSARY TO MAKE NEW CONSTRUCTION POSSIBLE.
L. THE SEISMIC BRACING AND ANCHORAGE OF PIPING SHALL BE IN
ACCORDANCE WITH GUIDLINES FOR SEISMIC RESTRAINTS OF
PLUMBING SYSTEMS PUBLISHED BY SMACNA.
M. SEISMIC DESIGN REQUIREMENTS OF THE PROJECT SHALL
CONFORM TO VA PLUMBING AND SEISMIC DESIGN MANUALS, H-18-8.
N. FOR THE PROJECT PHASES AND STAGES, ALL NEW REPLACEMENT
PIPING SHALL BE INSTALLED WITH THE MOST CURRENT
REQUIREMENT FOR SEISMIC RESTRAINTS.
O. ALL WORK ON SANITARY SEWER AND CHEMICAL WASTE AND VENT
PIPING SHALL BE IN ACCORDANCE WITH VA SPECIFICATIONS: 22 05
11, 22 08 00, 22 13 00 AND 22 66 00 AND THE VA PLUMBING DESIGN
MANUAL, 2014 OR MOST CURRENT VERSION.
GENERAL SHEET NOTES
1 REFER TO PLUMBING FIXTURE SHEDULE ON P - 600 SERIES SHEETS FOR
EXISTING PLUMBING FIXTURE TYPES
2 WASTE AND VENT PIPING TO BE REPLACED, BELOW. SEE PLUMBING PLANS.
KEYNOTES
Revisions: Date: Expires 6.30.16Expires: 6/30/18
01_FIRST FLOOR
100' - 0"
02_SECOND FLOOR
117' - 3"
A
03_THIRD FLOOR
134' - 6"
04_FOURTH FLOOR
151' - 9"
05_FIFTH FLOOR
169' - 0"
00_GROUND FLOOR
79' - 4 1/4"
06_SIXTH FLOOR
186' - 3"
07_ROOF
204' - 0"
BCDEFGHJKLMNOPQ
PB_PIPE BASEMENT
69' - 4 1/4"
RS
01_FIRST FLOOR
100' - 0"
02_SECOND FLOOR
117' - 3"
03_THIRD FLOOR
134' - 6"
04_FOURTH FLOOR
151' - 9"
05_FIFTH FLOOR
169' - 0"
00_GROUND FLOOR
79' - 4 1/4"
06_SIXTH FLOOR
186' - 3"
07_ROOF
204' - 0"
2 3 4 5 6 7 8 9 11 1210 13 14 15 16 17 18
40'-8"39'-4"
PB_PIPE BASEMENT
69' - 4 1/4"
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION DOCUMENTS
SUBMISSION - ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Mechanical:
AREA D
B500 KEY PLAN
AREA B
AREA A
AREA C
A1A2
C1C2
35% SCHEMATIC DESIGN SUBMISSION 09/14/2017
65% DESIGN DEVELOPMENT SUBMISSION 10/11/2017
100% CONSTRUCTION DOCUMENTS SUBMISSION - ISSUED FOR CONSTRUCTION
11/01/2017
95% CONSTRUCTION DOCUMENTS - OWNER REVIEW
11/20/2017
B
IM
/6
-1
-1
W
L R e tr o fi t S e w e r
S y s te m B s t, th th
F L /6
-1
-1
W
L V
A G
L A
H C
S -R e tr o fi tS e w e r-
B .r v t
/2
/2
:4 :2
P
M
A-201
ARCHITECTURAL EXTERIOR ELEVATIONS
TRIPLE C The A/E Group
4401 Atlantic Avenue, Suite 200
Long Beach, CA 90807
(562) 452-7175
Mat Perkins
P2S Engineering
5000 East Spring Street, 8th Floor
Long Beach, CA 90815
(562) 497-2999
Mikhail Fuks, P.E.
RETROFIT SEWER SYSTEM B500
FIRST, FIFTH & SIXTH FLOORS
11301 Wilshire Blvd., Los Angeles, CA 90073
691-17-104WL
B500
NOVEMBER 20, 2017 M. PERKINS K. LUKE
3/64" = 1'-0"
EXTERIOR ELEVATION - EAST
3/64" = 1'-0"
NORTH
Revisions: Date: Expires 6.30.16Expires: 6/30/18
1 2 3 4 5 6 7 8 9 11 1210 13 14 15 16 17 18
00_GROUND
FLOOR
79' - 4 1/4"
01_FIRST FLOOR
100' - 0"
02_SECOND
FLOOR
117' - 3"
03_THIRD FLOOR
134' - 6"
04_FOURTH
FLOOR
151' - 9"
05_FIFTH FLOOR
169' - 0"
06_SIXTH FLOOR
186' - 3"
07_ROOF
204' - 0"
PB_PIPE
BASEMENT
69' - 4 1/4"
6th Floor
5th Floor
1st Floor
Ground Floor
Pipe Basement
AREA OF WORK AREA OF WORK
Penthouse
ABCDEFGHJKLMNOPQRS
00_GROUND
FLOOR
79' - 4 1/4"
01_FIRST FLOOR
100' - 0"
02_SECOND
FLOOR
117' - 3"
03_THIRD FLOOR
134' - 6"
04_FOURTH
FLOOR
151' - 9"
05_FIFTH FLOOR
169' - 0"
06_SIXTH FLOOR
186' - 3"
07_ROOF
204' - 0"
PB_PIPE
BASEMENT
69' - 4 1/4"
6th Floor
5th Floor
1st Floor
Ground Floor
Pipe Basement
AREA OF WORK AREA OF WORK
Penthouse
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION DOCUMENTS
SUBMISSION - ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Mechanical:
AREA D
B500 KEY PLAN
AREA B
AREA A
AREA C
A1A2
C1C2
35% SCHEMATIC DESIGN SUBMISSION 09/14/2017
65% DESIGN DEVELOPMENT SUBMISSION 10/11/2017
100% CONSTRUCTION DOCUMENTS SUBMISSION - ISSUED FOR CONSTRUCTION
11/01/2017
95% CONSTRUCTION DOCUMENTS - OWNER REVIEW
11/20/2017
B
IM
/6
-1
-1
W
L R e tr o fi t S e w e r
S y s te m B s t, th th
F L /6
-1
-1
W
L V
A G
L A
H C
S -R e tr o fi tS e w e r-
B .r v t
/2
/2
:4 :3
P
M
A-301
ARCHITECTURAL SECTIONS - BUILDING
TRIPLE C The A/E Group
4401 Atlantic Avenue, Suite 200
Long Beach, CA 90807
(562) 452-7175
Mat Perkins
P2S Engineering
5000 East Spring Street, 8th Floor
Long Beach, CA 90815
(562) 497-2999
Mikhail Fuks, P.E.
RETROFIT SEWER SYSTEM B500
FIRST, FIFTH & SIXTH FLOORS
11301 Wilshire Blvd., Los Angeles, CA 90073
691-17-104WL
B500
NOVEMBER 20, 2017 M. PERKINS K. LUKE
1" = 20'-0"
BUILDING SECTION - EAST/WEST
1" = 20'-0"
BUILDING SECTION - NORTH/SOUTH
Revisions: Date: Expires 6.30.16Expires: 6/30/18
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| A-105C - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA C |
| A-105D - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA D |
| A-106 - ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE |
| A-106A - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A |
| A-106B - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B |
| A-106C - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C |
| A-106D - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D |
| A-201 - ARCHITECTURAL EXTERIOR ELEVATIONS |
| A-301 - ARCHITECTURAL SECTIONS - BUILDING |
| AS100 - ARCHITECTURAL SITE PLAN |
| G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| P-600 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-601 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-602 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-603 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-604 - PLUMBING FIXTURE SCHEDULES - SIXTH FLOOR AND SUMMARY |
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| A-105C - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA C |
| A-105D - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA D |
| A-106 - ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE |
| A-106A - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A |
| A-106B - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B |
| A-106C - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C |
| A-106D - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D |
| A-201 - ARCHITECTURAL EXTERIOR ELEVATIONS |
| A-301 - ARCHITECTURAL SECTIONS - BUILDING |
| AS100 - ARCHITECTURAL SITE PLAN |
| G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| P-600 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-601 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-602 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-603 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-604 - PLUMBING FIXTURE SCHEDULES - SIXTH FLOOR AND SUMMARY |
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - AS100 - Architectural Site Plan |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| A-105C - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA C |
| A-105D - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA D |
| A-106 - ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE |
| A-106A - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A |
| A-106B - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B |
| A-106C - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C |
| A-106D - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D |
| A-201 - ARCHITECTURAL EXTERIOR ELEVATIONS |
| A-301 - ARCHITECTURAL SECTIONS - BUILDING |
| AS100 - ARCHITECTURAL SITE PLAN |
| G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| P-600 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-601 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-602 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-603 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-604 - PLUMBING FIXTURE SCHEDULES - SIXTH FLOOR AND SUMMARY |
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| A-105C - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA C |
| A-105D - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA D |
| A-106 - ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE |
| A-106A - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A |
| A-106B - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B |
| A-106C - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C |
| A-106D - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D |
| A-201 - ARCHITECTURAL EXTERIOR ELEVATIONS |
| A-301 - ARCHITECTURAL SECTIONS - BUILDING |
| AS100 - ARCHITECTURAL SITE PLAN |
| G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| P-600 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-601 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-602 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-603 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-604 - PLUMBING FIXTURE SCHEDULES - SIXTH FLOOR AND SUMMARY |
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| A-105C - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA C |
| A-105D - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA D |
| A-106 - ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE |
| A-106A - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A |
| A-106B - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B |
| A-106C - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C |
| A-106D - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D |
| A-201 - ARCHITECTURAL EXTERIOR ELEVATIONS |
| A-301 - ARCHITECTURAL SECTIONS - BUILDING |
| AS100 - ARCHITECTURAL SITE PLAN |
| G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| P-600 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-601 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-602 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-603 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-604 - PLUMBING FIXTURE SCHEDULES - SIXTH FLOOR AND SUMMARY |
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| A-105C - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA C |
| A-105D - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA D |
| A-106 - ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE |
| A-106A - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A |
| A-106B - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B |
| A-106C - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C |
| A-106D - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D |
| A-201 - ARCHITECTURAL EXTERIOR ELEVATIONS |
| A-301 - ARCHITECTURAL SECTIONS - BUILDING |
| AS100 - ARCHITECTURAL SITE PLAN |
| G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| P-600 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-601 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-602 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-603 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-604 - PLUMBING FIXTURE SCHEDULES - SIXTH FLOOR AND SUMMARY |
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| A-105C - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA C |
| A-105D - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA D |
| A-106 - ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE |
| A-106A - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A |
| A-106B - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B |
| A-106C - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C |
| A-106D - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D |
| A-201 - ARCHITECTURAL EXTERIOR ELEVATIONS |
| A-301 - ARCHITECTURAL SECTIONS - BUILDING |
| AS100 - ARCHITECTURAL SITE PLAN |
| G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| P-600 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-601 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-602 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-603 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-604 - PLUMBING FIXTURE SCHEDULES - SIXTH FLOOR AND SUMMARY |
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| A-105C - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA C |
| A-105D - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA D |
| A-106 - ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE |
| A-106A - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A |
| A-106B - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B |
| A-106C - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C |
| A-106D - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D |
| A-201 - ARCHITECTURAL EXTERIOR ELEVATIONS |
| A-301 - ARCHITECTURAL SECTIONS - BUILDING |
| AS100 - ARCHITECTURAL SITE PLAN |
| G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| P-600 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-601 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-602 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-603 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-604 - PLUMBING FIXTURE SCHEDULES - SIXTH FLOOR AND SUMMARY |
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| A-105C - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA C |
| A-105D - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA D |
| A-106 - ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE |
| A-106A - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A |
| A-106B - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B |
| A-106C - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C |
| A-106D - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D |
| A-201 - ARCHITECTURAL EXTERIOR ELEVATIONS |
| A-301 - ARCHITECTURAL SECTIONS - BUILDING |
| AS100 - ARCHITECTURAL SITE PLAN |
| G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| P-600 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-601 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-602 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-603 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-604 - PLUMBING FIXTURE SCHEDULES - SIXTH FLOOR AND SUMMARY |
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| A-105C - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA C |
| A-105D - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA D |
| A-106 - ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE |
| A-106A - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A |
| A-106B - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B |
| A-106C - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C |
| A-106D - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D |
| A-201 - ARCHITECTURAL EXTERIOR ELEVATIONS |
| A-301 - ARCHITECTURAL SECTIONS - BUILDING |
| AS100 - ARCHITECTURAL SITE PLAN |
| G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| P-600 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-601 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-602 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-603 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-604 - PLUMBING FIXTURE SCHEDULES - SIXTH FLOOR AND SUMMARY |
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| A-105C - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA C |
| A-105D - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA D |
| A-106 - ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE |
| A-106A - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A |
| A-106B - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B |
| A-106C - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C |
| A-106D - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D |
| A-201 - ARCHITECTURAL EXTERIOR ELEVATIONS |
| A-301 - ARCHITECTURAL SECTIONS - BUILDING |
| AS100 - ARCHITECTURAL SITE PLAN |
| G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| P-600 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-601 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-602 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-603 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-604 - PLUMBING FIXTURE SCHEDULES - SIXTH FLOOR AND SUMMARY |
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |
| A-101C1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C1 |
| A-101C2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA C2 |
| A-101D - ARCHITECTURAL PLAN - FIRST FLOOR - AREA D |
| A-105 - ARCHITECTURAL PLAN - FIFTH FLOOR - COMPOSITE |
| A-105A - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA A |
| A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| A-105C - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA C |
| A-105D - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA D |
| A-106 - ARCHITECTURAL PLAN - SIXTH FLOOR - COMPOSITE |
| A-106A - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA A |
| A-106B - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA B |
| A-106C - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA C |
| A-106D - ARCHITECTURAL PLAN - SIXTH FLOOR - AREA D |
| A-201 - ARCHITECTURAL EXTERIOR ELEVATIONS |
| A-301 - ARCHITECTURAL SECTIONS - BUILDING |
| AS100 - ARCHITECTURAL SITE PLAN |
| G-000 - GENERAL COVER SHEET AND DRAWING INDEX |
| G-001 - GENERAL NOTES, SYMBOLS AND SCHEDULES |
| P-600 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-601 - PLUMBING FIXTURE SCHEDULES - FIRST FLOOR |
| P-602 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-603 - PLUMBING FIXTURE SCHEDULES - FIFTH FLOOR |
| P-604 - PLUMBING FIXTURE SCHEDULES - SIXTH FLOOR AND SUMMARY |
| 691-17-104WL_VAGLAHCS-RetrofitSewer-B500 - Sheet - A-105B - ARCHITECTURAL PLAN - FIFTH FLOOR - AREA B |
| Sheets |
| A-101 - ARCHITECTURAL PLAN - FIRST FLOOR COMPOSITE |
| A-101A1 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A1 |
| A-101A2 - ARCHITECTURAL PLAN - FIRST FLOOR - AREA A2 |
| A-101B - ARCHITECTURAL PLAN - FIRST FLOOR - AREA B |