36C25626R0047 EXHIBIT D.docx

DOCX document 20 KB Posted

Attached to
Z1DA--667-26-111 CON Abate Central Chase & Replace Fire Main
Solicitation number
36C25626R0047
Issued by

About this file

This is a Contractor Evaluation Form for construction safety assessment as part of a solicitation for the Abate Central Chase & Replace Fire Main project at Overton Brooks VA Medical Center. The form is Exhibit D of solicitation 36C25626R0047 and is marked for official use only as source selection sensitive information.

The evaluation form requires contractors to provide three years of occupational safety and health data (2023-2025) including total man hours, number of OSHA reportable cases involving days away from work or restricted activity, calculated DART rates, and counts of serious, willful, or repeat OSHA violations. Contractors must submit supporting documentation including OSHA 300 and 300a forms, identify the individual administering their Safety and Health Program, and provide their current Experience Modification Rate (EMR) from their insurance carrier on carrier letterhead. If the EMR exceeds 1.0, contractors must attach a written explanation from the insurance carrier detailing reasons for the elevated rate and the anticipated timeline for reduction to 1.0 or below. This safety-focused evaluation component is designed to assess contractor performance and risk management capabilities for the fire main replacement project.

View the file

Other files

File Type Posted
36C25626R0047 0003.pdf PDF
36C25626R0047 0002.docx DOCX document
Attachment No. 1 Piping Asbestos Survey.pdf PDF
Attachment No. 2 Pre-bid Conference Sign-in Sheet.pdf PDF
Attachment No. 3 WD LA20260031.pdf PDF
36C25626R0047 0002.pdf PDF
36C25626R0047 0001.pdf PDF
Abate Central Chase - 13 - ICRA.pdf PDF
36C25626R0047 EXHIBIT B.docx DOCX document
36C25626R0047 EXHIBIT C.docx DOCX document
36C25626R0047.pdf PDF
Abate Central Chase - 1- SOW.pdf PDF
Abate Central Chase - 8 - CRA.pdf PDF
WD LA20260031 01022026.pdf PDF
Abate Chase - FY26 - Final Drawings.pdf PDF
Abate Chase - FY26 - IFC Specs - Updated.pdf PDF
Abate Central Chase - 14 - Class II Precautions.pdf PDF
36C25626R0047 EXHIBIT A.docx DOCX document
36C25626R0047 EXHIBIT E.docx DOCX document
36C25626R0047 EXHIBIT F.docx DOCX document
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOR OFFICIAL USE ONLY

Source Selection Sensitive Information—See FAR 2.101 & 3.104 667-26-111 Abate Central Chase & Replace Fire Main 36C25626R0047

Exhibit D Contractor Evaluation Form Construction Safety

Company Name:

Address:

Telephone: Fax:

Email:

Contact:

1. Utilizing your OSHA 300 Forms, please complete the following information:

Category
2023
2024
2025

Number of man hours (jobsite and office).

Number of cases involving days away from work, restricted activity, or both (Column H and I of OSHA 300).

Days away, restricted, or transferred rate (# of days away, restricted, or transferred cases x 200,000/# of man hours) (DART Rate).

Number of serious, willful, or repeat violations from OSHA within the last 3 years. Please attach explanations for any violations.

Please attach copies of the following documents: OSHA 300 and 300a Forms.

These forms can be accessed through the OSHA publications search page:

http://www.osha.gov/pls/publications/publication.html.

2.Who administers your company’s Safety and Health Program?
3.Company’s current Insurance Experience Modification Rate (EMR):

The above EMR rate must be obtained from offeror’s insurance carrier and furnished on insurance carrier’s letterhead. If EMR is greater than 1.0, attach a written explanation of the EMR from insurance carrier on insurance carrier’s letterhead describing the reasons for the EMR and the anticipated date the EMR may be reduced to 1.0 or below.

File details come from the government source that posted it. Updated .