FA123 - BLDG 18 - FLOOR PLANS - AMENDMENT 0003.pdf

PDF 978 KB Posted

Attached to
Y1DA--564-21-2-605-0001 Correct Fire Alarm Deficiencies (564-17-103)
Solicitation number
36C25621R0012
Issued by

About this file

This document outlines a federal contract opportunity to correct fire alarm deficiencies at the Veterans Health Care System of the Ozarks. The solicitation will be issued as a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses through request for proposal procedures. The tentative date for issuing the RFP is October 16, 2020, with proposals due around November 16, 2020. The anticipated contract award date is approximately 30 days after receipt of proposals. The recommended contract performance period is 240 calendar days after issuance of the notice to proceed. The location of work is at 1100 N. College Ave., Fayetteville, AR 72703. Offerors must be registered and verified in the Vendor Information Pages and System for Award Management databases. The construction cost range is between $500,000 to $1 million, and the NAICS code applicable is 236220.

View the file

Other files

File Type Posted
AMENDMENT TO EXTEND 36C25621R0012 0004.docx DOCX document
FA119 - BLDG 7 - FLOOR PLANS - AMENDMENT 0003.pdf PDF
FA100 - GENERAL NOTES AND LEGENDS - AMENDMENT 0003.pdf PDF
FA108 - BLDG 1 THIRD FLOOR PLAN - PART 2 - AMENDMENT 0003.pdf PDF
283100 - AMENDMENT 0003.pdf PDF
FA109 - BLDG 1 FOURTH FLOOR PLAN - AMENDMENT 0003.pdf PDF
FA115 - BLDG 4 BASEMENT AND FIRST FLOOR PLANS - AMENDMENT 0003.pdf PDF
FA103 - BLDG 1 FIRST FLOOR PLAN - PART 1 - AMENDMENT 0003.pdf PDF
FA118 - BLDG 6 - FLOOR PLANS - AMENDMENT 0003.pdf PDF
36C25621R0012 SOLICITATION AMENDMENT 0003.docx DOCX document
FA117 - BLDG 5 - FLOOR PLANS - AMENDMENT 0003.pdf PDF
FA107 - BLDG 1 THIRD FLOOR PLAN - PART 1 - AMENDMENT 0003.pdf PDF
FA102 - BLDG 1 BASEMENT PLAN - PART 2 - AMENDMENT 0003.pdf PDF
S02 Attachment B RFIs.docx DOCX document
FA101 - BLDG 1 BASEMENT PLAN - PART 1 - AMENDMENT 0003.pdf PDF
FA121 - BLDG 9 - FLOOR PLANS - AMENDMENT 0003.pdf PDF
36C25621R0012 AMENDMENT 0003.docx DOCX document
FA131 - BLDG 26_27_29 - FLOOR PLANS - AMENDMENT 0003.pdf PDF
AMENDMENT TO EXTEND - 36C25621R0012 0002.docx DOCX document
564-17-103 Prebid Walk Signin (002).pdf PDF
AMENDMENT 36C25621R0012 0001.docx DOCX document
WAGE DETERMINATION AR20200035 - 1-3-2020.pdf PDF
EXHIBIT B Past and Present Performance Questionnaire.docx DOCX document
EXHIBIT A PERFORMANCE RELEVANCY SURVEY v2.docx DOCX document
Fayetteville Fire Alarm Deficiencies BD Submission Drawings 200716.pdf PDF
Fayetteville Fire Alarm Deficiencies BD Submission Specifications Revised 200727.pdf PDF
SOLICITATION - 36C25621R0012_1.docx DOCX document
EXHIBIT C CONTRACTOR EVALUATION FORM CONSTRUCTION SAFETY v2.docx DOCX document
36C25621R0012.docx DOCX document
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0.1

K

WATER SERVICE

104-18

ELECTRICAL SERVICE

103-18

J

403-18

P-1

ELEVATOR EQUIPMENT

102-18

402-18

P-2

101-18

LOBBY

S1-01-18

STAIR 1

H

G

1.3 2 3 4

F

E

D.3

D

C

B.8

B

A

FACP

J

G

H

K

0.1

1 1.3 2 3 4

A

B

B.8

C

D.3

D

E

F

FACPF

FACP

LOBBY

1 2 3 4 5

Drawing Title:Seal:

FULLY SPRINKLERED

ARCHITECT / ENGINEERS:

Project Title:

Date:

Project Number:

Drawing Number:

Drawn:Checked:

Building Number:

D C

B A

Revisions:

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

P 704.814.1320

F 704.321.0833

Project Phase:

D C

B A

1 2 3 4 5 6

Location:

CONSULTANTS:

U.S. Department of Veterans Affairs t h r e e i n c h e s o n e f o o t t h r e e q u a r t e r s i n c h e f o o t o n e i n c e f o o t o n e a n d o n e h a l f i n c h e s e f o o t o n e h a l f i n c e f o o t t h r e e e i g h t h s i n c e f o o t o n e e i g h t h i n c e f o o t o n e q u a r t e r i n c e f o o t

H A R R E L L

D E S I G N G R O U P , P C formerly HARRELL, SALTRICK & HOPPER, PC

HDG PROJECT: 18022

564-17-103CORRECT FIRE ALARM

DEFICIENCIES

KEYPLAN

VETERANS HEALTHCARE

SYSTEM OF THE OZARKS

Sheet of

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

RATED WALL LEGEND

BID DOCUMENTS

JULY 16, 2020 LEH GWG

BUILDING 18

FLOOR PLANS

FA123

PLAN NORTH

TRUE NORTH

SHEET KEYNOTES

GENERAL SHEET NOTES

1. NFS-320 FIRE ALARM PANEL .

2. NEW NFS-320 FIRE ALARM PANEL.

3. EXISTING STROBE POWER SUPPLY.

4. CAGE BUILT IN THE ELECTRICAL ROOM FOR

TELECOMMUNICATIONS EQUIPMENT.

SHEET LEGEND

1. THE BUILDING 18 FIRE ALARM PANEL SHALL BE REPLACED

WITH A NEW PANEL AT A NEW LOCATION. THE EXISTING

PANEL IS A NOTIFIER NFS-320 WTH VOICE COMMAND

OPTION. INSTALL THE NEW PANEL, INSTALL CONDUIT AND

WIRING TO POINTS WHERE EXISTING CIRCUITS CAN BE

INTERCEPTED AND AND ALL OTHER POSSIBLE PREPARATION

TO LIMIT THE TRANSITION FROM THE EXISTING TO THE NEW

PANEL. PLAN TO MAKE THESE CONNECTIONS AT THE

EXISTING PANEL LOCATION.

2. TURN OVER THE EXISTING PANEL AND ALL OTHER REMOVED

DEVICES TO THE VA FOR USE OR DISPOSAL.

3. IN ADDITION TO CONNECTING NAC PANEL, THE CAMPUS FIRE

ALARM FIBER SHALL BE ROUTED AND CONNECTED TO THE

NEW PANEL. FIBER ENTERS BUILDING IN LEVEL 1

ELECTRICAL ROOM 103-18.

4. REFER TO SPECIFICATION SECTION 01 35 26 AND DRAWING

GC100 FOR INFECTION CONTROL REQUIREMENTS. WORK IN

ALL AREAS SHALL COMPLY WITH THE REQUIRED INFECTION

CONTROL MEASURES FOR THE CLASS. AREAS NOT

OTHERWISE IDENTIFIED SHALL BE TREATED AS CLASS II.

27 39

ALL WORK ON THIS SHEET SHALL BE

DEDUCTIVE ALTERNATE NO. 2.

SEE SCHEDULE OF DEDUCTIVE BID

ITEMS ON SHEET GI001.

AutoCAD SHX Text

REVISION DESCRIPTION

AutoCAD SHX Text

REVISION NO.

AutoCAD SHX Text

2 HOUR RATED FIRE/SMOKE WALL

AutoCAD SHX Text

1 HOUR FIRE RATE WALL

AutoCAD SHX Text

1 HOUR RATED FIRE/SMOKE WALL

AutoCAD SHX Text

2 HOUR RATED WALL

AutoCAD SHX Text

SMOKE-TIGHT WALL

AutoCAD SHX Text 1.

AutoCAD SHX Text

AMENDMENT 0003

AutoCAD SHX Text

DATE

AutoCAD SHX Text 2/2/2021

AutoCAD SHX Text

AutoCAD SHX Text 1/16" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text 32'

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

BUILDING 18 - LEVEL 1 PLAN

AutoCAD SHX Text D1

AutoCAD SHX Text

AutoCAD SHX Text 1/16" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text 32'

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

BUILDING 18 - LEVEL 3 FLOOR PLAN

AutoCAD SHX Text D3

AutoCAD SHX Text

EXISTING PLANS

AutoCAD SHX Text

EXISTING DEVICE OR EQUIPMENT

AutoCAD SHX Text

NEW PLANS

AutoCAD SHX Text

NEW DEVICE OR EQUIPMENT

AutoCAD SHX Text

EXISTING DEVICE OR EQUIPMENT

AutoCAD SHX Text

AutoCAD SHX Text

Sheets and Views
FA123
2021-02-03T07:50:17-0500
John G. Ross, PE

File details come from the government source that posted it. Updated .