FA100 - GENERAL NOTES AND LEGENDS - AMENDMENT 0003.pdf

PDF 903 KB Posted

Attached to
Y1DA--564-21-2-605-0001 Correct Fire Alarm Deficiencies (564-17-103)
Solicitation number
36C25621R0012
Issued by

About this file

This document summarizes a federal contract opportunity for corrective fire alarm work at a Veterans Health Care facility. The solicitation requests proposals from Service-Disabled Veteran-Owned Small Businesses to perform corrective fire alarm work at the Veterans Health Care System of the Ozarks in Fayetteville, Arkansas for an estimated cost between $500,000 to $1,000,000. Interested vendors must check the SAM website for proposal due dates and amendments, with the tentative proposal due date of November 16, 2020. Offerors must represent their SDVOSB status and small business size, and have a CVE verification at time of proposal submission. The anticipated period of performance is 240 calendar days from notice to proceed.

View the file

Other files

File Type Posted
AMENDMENT TO EXTEND 36C25621R0012 0004.docx DOCX document
FA119 - BLDG 7 - FLOOR PLANS - AMENDMENT 0003.pdf PDF
FA108 - BLDG 1 THIRD FLOOR PLAN - PART 2 - AMENDMENT 0003.pdf PDF
283100 - AMENDMENT 0003.pdf PDF
FA109 - BLDG 1 FOURTH FLOOR PLAN - AMENDMENT 0003.pdf PDF
FA115 - BLDG 4 BASEMENT AND FIRST FLOOR PLANS - AMENDMENT 0003.pdf PDF
FA103 - BLDG 1 FIRST FLOOR PLAN - PART 1 - AMENDMENT 0003.pdf PDF
FA118 - BLDG 6 - FLOOR PLANS - AMENDMENT 0003.pdf PDF
36C25621R0012 SOLICITATION AMENDMENT 0003.docx DOCX document
FA117 - BLDG 5 - FLOOR PLANS - AMENDMENT 0003.pdf PDF
FA107 - BLDG 1 THIRD FLOOR PLAN - PART 1 - AMENDMENT 0003.pdf PDF
FA123 - BLDG 18 - FLOOR PLANS - AMENDMENT 0003.pdf PDF
FA102 - BLDG 1 BASEMENT PLAN - PART 2 - AMENDMENT 0003.pdf PDF
S02 Attachment B RFIs.docx DOCX document
FA101 - BLDG 1 BASEMENT PLAN - PART 1 - AMENDMENT 0003.pdf PDF
FA121 - BLDG 9 - FLOOR PLANS - AMENDMENT 0003.pdf PDF
36C25621R0012 AMENDMENT 0003.docx DOCX document
FA131 - BLDG 26_27_29 - FLOOR PLANS - AMENDMENT 0003.pdf PDF
AMENDMENT TO EXTEND - 36C25621R0012 0002.docx DOCX document
564-17-103 Prebid Walk Signin (002).pdf PDF
AMENDMENT 36C25621R0012 0001.docx DOCX document
WAGE DETERMINATION AR20200035 - 1-3-2020.pdf PDF
EXHIBIT B Past and Present Performance Questionnaire.docx DOCX document
EXHIBIT A PERFORMANCE RELEVANCY SURVEY v2.docx DOCX document
Fayetteville Fire Alarm Deficiencies BD Submission Drawings 200716.pdf PDF
Fayetteville Fire Alarm Deficiencies BD Submission Specifications Revised 200727.pdf PDF
SOLICITATION - 36C25621R0012_1.docx DOCX document
EXHIBIT C CONTRACTOR EVALUATION FORM CONSTRUCTION SAFETY v2.docx DOCX document
36C25621R0012.docx DOCX document
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A AMPERE, AMMETER

AF AMPERE FRAME

AFF ABOVE FINISHED FLOOR

AIC AMPERES INTERRUPTING CAPACITY

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

C CONDUIT

CL CENTER LINE

CR CARD READER ACCESS

CU COPPER

DR DOOR

EC EMPTY CONDUIT

EMER EMERGENCY

EWC ELECTRIC WATER HEATER

EX EXISTING

G, GND GROUND

GF GROUND FAULT INTERRUPTER

HH HANDHOLE

HP HORSEPOWER

HS HOOD SUPPRESSION CONTROL

HZ HERTZ

IG ISOLATED GROUND

JB JUNCTION BOX

KVA KILOVOLT-AMPERES

KW KILOWATTS

LC LIGHTING CONTACTOR

LTG LIGHTING

PROVIDE FURNISH, INSTALL & CONNECT

RECPT RECEPTACLE

RL EXISTING ITEM TO BE RELOCATED

RM EXISTING ITEM TO REMAIN

RP EXISTING ITEM TO BE REPLACED

SC SECURITY CAMERA OUTLET

SN SOLID NEUTRAL

SW SWITCH

SWBD SWITCHBOARD

TV COMBINATION TV & RECEPT OUTLET

TYP TYPICAL

UG UNDER GROUND

UNO UNLESS NOTED OTHERWISE

V VOLT

LC LIGHTING CONTACTOR

WP WEATHERTIGHT GFI

WAP WIRELESS ACCESS POINT

XFMR TRANSFORMER

THIS SCHEDULE IS REPRESENTATIVE OF THOSE TYPICALLY FOUND ON THE PLANS BUT NOT ALL MAY BE UTILIZED

FIRE ALARM MANUAL PULL STATION, MOUNT AT 48" ABOVE FINISHED FLOOR. SUBSCRIPT

"K" INDICATES KEY OPERATED INSTITUTIONAL DEVICE.

ELECTRICAL SYMBOL LEGEND

FIRE ALARM COMBINATION CHIME AND STROBE DEVICE, SUBSCRIPT INDICATES CANDELA

RATING OTHERWISE 15 CANDELA. MOUNT AT A MINIMUM OF 80" ABOVE FINISHED FLOOR AND A

MINIMUM OF 6" BELOW FINISHED CEILING HEIGHT.

FIRE ALARM STROBE DEVICE, SUBSCRIPT INDICATES CANDELA RATING OTHERWISE 15

CANDELA. MOUNT AT A MINIMUM OF 80" ABOVE FINISHED FLOOR AND A MINIMUM OF 6" BELOW

FINISHED CEILING HEIGHT.

FIRE ALARM SMOKE DETECTOR, CEILING SURFACE MOUNTED.

FIRE ALARM SYSTEM DUCT DETECTOR WITH SAMPLING TUBES, FURNISHED AND WIRED BY

ELECTRICAL CONTRACTOR TO THE LOCAL FACP, INSTALL BY MECHANICAL CONTRACTOR

UNLESS OTHERWISE INDICATED.

FIRE ALARM SYSTEM DUCT DETECTOR REMOTE INDICATOR LIGHT.

L

FIRE ALARM SYSTEM RELAY, CONTROL OR MONITORING TYPE AS REQUIRED.

FIRE ALARM END OF LINE RESISTOR.

EOLR

RM

FIRE ALARM SPRINKLER SYSTEM FLOW SWITCH.

FIRE ALARM SPRINKLER SYSTEM TAMPER SWITCH.

FIRE ALARM SYSTEM HEAT DETECTOR.

FIRE ALARM SYSTEM SPEAKER, WALL MOUNTED.

FIRE ALARM SYSTEM SPEAKER, CEILING MOUNTED.

FIRE ALARM SYSTEM HORN/STROBE, CEILING MOUNTED.

H

FIRE ALARM SYSTEM STROBE, CEILING MOUNTED.

FIRE ALARM SYSTEM DOOR HOLD OPEN DEVICE.

FIRE ALARM VOICE NOTIFICATION AMPLIFIER AND STROBE POWER SUPPLY

FAVP

FIRE ALARM ADDRESSABLE VOICE COMMAND CONTROL PANEL

FIRE ALARM STANDARD ADDRESSABLE CONTROL PANEL

A. ALL WORK SHALL BE DONE ACCORDING TO THE NATIONAL ELECTRICAL CODE AND OTHER

APPLICABLE REFERENCED CODES. TAKE PARTICULAR CARE TO OBSERVE DURING BID

PREPARATION ANY POSSIBLE CODE DISCREPANCIES AND BRING TO THE ATTENTION OF

THE ENGINEER FOR RESOLUTION.

B. THE CONTRACTOR SHALL MAINTAIN, ON THE SITE, AN ADEQUATE ADMINISTRATIVE SPACE

WHERE ONE COMPLETE SET OF PLANS AND SPECIFICATIONS SHALL BE KEPT FOR THE

WORK OF ALL TRADES ON THE PROJECT. THESE PLANS AND SPECIFICATIONS SHALL BE IN

ADDITION TO THE SETS USED BY THE INSTALLING ELECTRICIAN IN CARRYING OUT THEIR

DAY-TO-DAY WORK ON THE PROJECT.

C. CONTRACTOR SHALL ALSO MAINTAIN AT THE SITE A COMPLETE SET OF ALL SHOP

DRAWINGS, EQUIPMENT CUTS, MANUFACTURER'S WIRING DIAGRAMS AND INSTALLATION

DATA. INSTALLING PERSONNEL SHALL STUDY THIS DATA BEFORE AND DURING

INSTALLATION AND ROUGH-IN SO AS TO PREPARE FOR THE PROPER FIT AND FUNCTION

UPON COMPLETION.

D. PENETRATIONS OF REQUIRED SMOKE TIGHT PARTITIONS SHALL BE SEALED USING U.L.

LISTED METHODS. COORDINATION WITH THE OWNER AND ENGINEER SHALL BE

MAINTAINED TO INSURE THAT THE INTEGRITY OF THE SMOKE BARRIER IN MAINTAINED.

E. WHERE PENETRATIONS ARE MADE THROUGH A REQUIRED FIRE-RESISTIVE WALL, FLOOR,

OR PARTITION FOR THE PURPOSE OF RUNNING CABLE OR RACEWAYS FIRE STOP PER

NFPA. COORDINATION WITH THE OWNER AND ENGINEER SHALL BE MAINTAINED TO

INSURE THAT THIS FIRE STOPPING IS ACCOMPLISHED. USE ONLY APPROVED ASSEMBLIES

SUCH AS THE FOLLOWING:

F. CONDUIT PENETRATIONS OF 1 & 2 HOUR GYPBOARD WALLS - U.L.#WL1001 CONDUIT

PENETRATIONS OF 1 & 2 HOUR CONCRETE OR BLOCK WALLS - U.L.#CAJ1001 CONDUIT

PENETRATIONS OF 1 & 2 HOUR CONCRETE FLOORS - U.L.#CAJ1001.

G. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE U.L.

LISTED AND LABELED.

H. NEW FLOOR AND WALL SLEEVES SHALL BE HILTI-CP653 FOUR INCH SPEED SLEEVES.

I. BEFORE STARTING WORK THE CONTRACTOR SHALL PERFORM A COMPLETE

WALK-THROUGH OF THE PROJECT TO EXAMINE EXISTING EQUIPMENT, DEVICES AND THE

WORK REQUIRED. PROVIDE A REPORT OF ANY OBSERVATIONS THAT MAY AFFECT THE

WORK.

K. ALL SMOKE DETECTORS SHALL BE LOCATED AT A MINIMUM OF 3' FROM A SUPPLY OR

RETURN GRILLE.

FIRE ALARM SYSTEM SPEAKER/STROBE, CEILING MOUNTED.

M

F

F

FS

TS

F

GENERAL NOTES

ABBREVIATIONS & ACRONYMS

FAVC

FACP

FASP

FAVA

FAAP

FIRE ALARM STROBE POWER SUPPLY

FIRE ALARM VOICE DIGITAL AMPLIFIER

FIRE ALARM ANNUNCIATION PANEL

FIRE ALARM SYSTEM HORN/STROBE, WALL MOUNTED.

H

F

FIRE ALARM SYSTEM CARBON MONOXIDE DETECTOR

C

J. WHERE NEW DEVICES ARE INDICATED TO BE ADDED TO EXISTING

SYSTEMS, THE NEW DEVICES SHALL BE FULLY COMPATIBLE WITH

THE EXISTING SYSTEMS SO AS TO MAINTAIN ALL SYSTEM

FUNCTIONS AND ALL REQUIRED FIRE ALARM CONFORMANCE

LISTINGS, INDEPENDENT TESTING LABORATORY LABELINGS, AND

ALL EXISTING FIRE ALARM SERVICE CONTRACTS.

1 2 3 4 5

Drawing Title:Seal:

FULLY SPRINKLERED

ARCHITECT / ENGINEERS:

Project Title:

Date:

Project Number:

Drawing Number:

Drawn:Checked:

Building Number:

D C

B A

Revisions:

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

P 704.814.1320

F 704.321.0833

Project Phase:

D C

B A

1 2 3 4 5 6

Location:

CONSULTANTS:

U.S. Department of Veterans Affairs

H A R R E L L

D E S I G N G R O U P , P C formerly HARRELL, SALTRICK & HOPPER, PC

HDG PROJECT: 18022

BID DOCUMENTS

JULY 16, 2020

564-17-103CORRECT FIRE ALARM

DEFICIENCIES

VETERANS HEALTHCARE

SYSTEM OF THE OZARKS

Sheet of

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

LEH GWG

GENERAL NOTES

AND LEGENDS

FA100

04 39

AutoCAD SHX Text

REVISION DESCRIPTION

AutoCAD SHX Text

REVISION NO.

AutoCAD SHX Text 1.

AutoCAD SHX Text

AMENDMENT 0003

AutoCAD SHX Text 2/2/2021

AutoCAD SHX Text

Sheets and Views
FA100
2021-02-03T07:57:00-0500
John G. Ross, PE

File details come from the government source that posted it. Updated .