FA121 - BLDG 9 - FLOOR PLANS - AMENDMENT 0003.pdf
PDF 1012 KB Posted
- Solicitation number
- 36C25621R0012
About this file
This document includes floor plans for amendments to a federal contract opportunity to correct fire alarm deficiencies at a Veterans Health Administration facility. The contract is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses to perform work at the Veterans Health Care System of Ozarks in Fayetteville, Arkansas for an estimated cost between $500,000 and $1,000,000. The solicitation number is 36C25621R0012 and the work includes providing all labor, materials and equipment to complete the fire alarm deficiency corrections according to the project scope, drawings and specifications. The tentative request for proposals date is October 16, 2020 with proposals due on or around November 30, 2020 and contract award anticipated within 30 days thereafter. The recommended period of performance is 240 calendar days from notice to proceed.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMPRESSOR
AIR
20 HP
DRYER
REFRIG
SOFTNER
WATER
GENERAL STORAGE
EMS STORAGE
SAFETY STORAGE
MACHINE SHOP/STOR. RM.
SERVICE ROOM
006 002
LAUNDRY MACHINE
EQUIPMENT ROOM
CRAWL
ACCESS
ELECTRICAL ROOM
FENCED IN
EQUIPMENT AREA
F
F
FS
TS
F
F
F
F F F
F
JB9
RECOVERY
WITH HEAT
LINT FILTER
SYSTEM
MONORAIL
GRAVITY
LINEN
SOIL
CLASSIFIED
SYSTEM
MONORAIL
LINEN
CLEAN
SYSTEM
MONORAIL
DRYFOLD
EXTRACTOR
WASHER
DRYERDRYER
DRYER
FINISHER
GARMENT
STATION
FOLDING
SMALL PIECE FOLDER
STATION
FOLDING
CLEAN LINEN TRANSPORT CONVEYOR
IRONER
FLATWORK
3-ROLL
FEEDER
SPREADER
CONVEYOR
FEED
STORAGE
FLATWORK
CONVEYOR
BELT
SORTING
CONVEYOR
TRANSPORT
AND
STORAGE
LINEN
SOILED
C A
R T
S
TANK
MIX
TANKS
STORAGE
CHEMICAL
EXTRACTOR
WASHER
EXTRACTOR
WASHER
EXTRACTOR
WASHER
SORTING & WASHING
RECEIVING AREA
100B
DRYING & FOLDING
LOAD-OUT/CART STOR.
OFFICE
ISSUE
WOMENS' TOILET
MENS' TOILET
EMPLOYEE LOUNGE
SOILED UTILITY
100A
F
F
F
F
F F
F
F
RECOVERY
WITH HEAT
LINT FILTER
SYSTEM
MONORAIL
GRAVITY
LINEN
SOIL
CLASSIFIED
SYSTEM
MONORAIL
LINEN
CLEAN
SYSTEM
MONORAIL
DRYFOLD
EXTRACTOR
WASHER
DRYERDRYER
DRYER
FINISHER
GARMENT
STATION
FOLDING
SMALL PIECE FOLDER
STATION
FOLDING
CLEAN LINEN TRANSPORT CONVEYOR
IRONER
FLATWORK
3-ROLL
FEEDER
SPREADER
CONVEYOR
FEED
STORAGE
FLATWORK
CONVEYOR
BELT
SORTING
CONVEYOR
TRANSPORT
AND
STORAGE
LINEN
SOILED
C A
R T
S
TANK
MIX
TANKS
STORAGE
CHEMICAL
EXTRACTOR
WASHER
EXTRACTOR
WASHER
EXTRACTOR
WASHER
SORTING & WASHING
RECEIVING AREA
100B
DRYING & FOLDING
LOAD-OUT/CART STOR.
OFFICE
ISSUE
WOMENS' TOILET
MENS' TOILET
EMPLOYEE LOUNGE
SOILED UTILITY
100A
F
F
H
H
HH
H
H
H
H
H
COMPRESSOR
AIR
20 HP
DRYER
REFRIG
SOFTNER
WATER
GENERAL STORAGE
EMS STORAGE
SAFETY STORAGE
MACHINE SHOP/STOR. RM.
SERVICE ROOM
006 002
LAUNDRY MACHINE
EQUIPMENT ROOM
CRAWL
ACCESS
ELECTRICAL ROOM
FENCED IN
EQUIPMENT AREA
F
F
FS
TS
H
H H H
F
H
H
JB9
1 2 3 4 5
Drawing Title:Seal:
FULLY SPRINKLERED
ARCHITECT / ENGINEERS:
Project Title:
Date:
Project Number:
Drawing Number:
Drawn:Checked:
Building Number:
D C
B A
Revisions:
8016 TOWER POINT DRIVE
CHARLOTTE, NC 28227
P 704.814.1320
F 704.321.0833
Project Phase:
D C
B A
1 2 3 4 5 6
Location:
CONSULTANTS:
U.S. Department of Veterans Affairs t h r e e i n c h e s o n e f o o t t h r e e q u a r t e r s i n c h e f o o t o n e i n c e f o o t o n e a n d o n e h a l f i n c h e s e f o o t o n e h a l f i n c e f o o t t h r e e e i g h t h s i n c e f o o t o n e e i g h t h i n c e f o o t o n e q u a r t e r i n c e f o o t
H A R R E L L
D E S I G N G R O U P , P C formerly HARRELL, SALTRICK & HOPPER, PC
HDG PROJECT: 18022
564-17-103CORRECT FIRE ALARM
DEFICIENCIES
KEYPLAN
VETERANS HEALTHCARE
SYSTEM OF THE OZARKS
Sheet of
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
Engineering Service
RATED WALL LEGEND
BID DOCUMENTS
JULY 16, 2020 LEH GWG
BUILDING 9
FLOOR PLANS
FA121
PLAN NORTH
TRUE NORTH
SHEET KEYNOTES
GENERAL SHEET NOTES
25 39
1. EXISTING DEVICE SHALL BE REMOVED AND REPLACED WITH
DEVICE IN A NEW LOCATION WHERE INDICATED ON THE NEW
WORK PLAN.
2. REPLACE DEVICE WITH NEW DEVICE SHOWN ON NEW WORK
PLAN.
3. RELOCATE EXISTING DEVICE AS SHOWN ON THE NEW WORK
PLAN.
4. ALL SPEAKERS IN BUILDING 9 SHALL BE REPLACED WITH
HORNS OR HORN/STROBES AS INDICATED ON NEW WORK
PLANS.
5. JUNCTION BOX REFERENCED FROM SHEET ES101, KEYNOTE
6 FOR BUILDING 40 FIRE ALARM CONNECTION.
6. CONDUIT RUN ON OUTSIDE OF BUILDING 11 FOR BUILDING 40
FIRE ALARM CONNECTION.
7. EXTEND CONDUIT THROUGH BUILDING 9 AND INSTALL ON
UNDERSIDE OF CANOPY BETWEEN BUILDING 8 AND 9.
FOLLOW PATH OF EXISTING TELECOMMUNICATIONS
CONDUITS INSTALLED BETWEEN THE TWO BUILDINGS.
1. EXISTING DEVICES TO REMAIN UNLESS OTHERWISE NOTED.
2. ALL FIRE ALARM WIRING TO BE INSTALLED IN CONDUIT.
3. BUILDING 9 IS CONNECTED TO THE BUILDING 8 FIRE ALARM
SYSTEM. STROBE POWER SUPPLIES AND SPEAKER
AMPLIFIERS ARE LOCATED IN BUILDING 8 AND PROGRAMMED
TO FOR INDEPENDENT OPERATION OF THE DEVICES IN THE
BUILDING.
4. REFER TO SPECIFICATION SECTION 01 35 26 AND DRAWING
GC100 FOR INFECTION CONTROL REQUIREMENTS. WORK IN
ALL AREAS SHALL COMPLY WITH THE REQUIRED INFECTION
CONTROL MEASURES FOR THE CLASS. AREAS NOT
OTHERWISE IDENTIFIED SHALL BE TREATED AS CLASS II.
SHEET LEGEND
EXISTING PLANS
EXISTING DEVICE OR EQUIPMENT
NEW PLANS
NEW DEVICE OR EQUIPMENT
EXISTING DEVICE OR EQUIPMENT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REVISION DESCRIPTION
AutoCAD SHX Text
REVISION NO.
AutoCAD SHX Text
2 HOUR RATED FIRE/SMOKE WALL
AutoCAD SHX Text
1 HOUR FIRE RATE WALL
AutoCAD SHX Text
1 HOUR RATED FIRE/SMOKE WALL
AutoCAD SHX Text
2 HOUR RATED WALL
AutoCAD SHX Text
SMOKE-TIGHT WALL
AutoCAD SHX Text 1.
AutoCAD SHX Text
AMENDMENT 0003
AutoCAD SHX Text
DATE
AutoCAD SHX Text 2/2/2021
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
BUILDING 9 - BASEMENT PLAN - EXISTING
AutoCAD SHX Text D1
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
BUILDING 9 - 1ST FLOOR PLAN - EXISTING
AutoCAD SHX Text D3
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
BUILDING 9 - BASEMENT PLAN - NEW
AutoCAD SHX Text B1
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
BUILDING 9 - 1ST FLOOR PLAN - NEW
AutoCAD SHX Text B3
AutoCAD SHX Text
| Sheets and Views |
| FA121 |
| 2021-02-03T07:51:01-0500 | |
| John G. Ross, PE |
File details come from the government source that posted it. Updated .