This document includes a fire protection plan drawing and specifications for the Upgrade Emergency Department Phase II project at the Colmery-O'Neil Veterans Administration Medical Center in Topeka, Kansas. The project involves reconfiguring existing sprinkler piping and heads to provide proper coverage per NFPA 13, including matching existing sprinkler head types and coordinating head locations with lights, diffusers, and exit signs. The related solicitation is for upgrade and renovation work on the emergency department and seeks contractor proposals through the vendor portal by the January 26, 2022 due date. A mandatory site visit will also take place on January 26, 2022 at the medical center for contractors to inspect the work areas. The work is exempt from state sales tax and the selected contractor must provide its Duns number. The project NAICS code is 236220 for Commercial and Institutional Building Construction up to $39.5 million.

View the file

Other files

File Type Posted
36C25522R0042 Amendment No.0004 589A5-15-115B ED Phase II.pdf PDF
589A5-15B-115_081400 INTERIOR WOOD DOORS SPECIFICATION.pdf PDF
SPECS 100CD_VA 589A5-15-115_084113 ALUM ENTRANCES STOREFRONTS ICU SLIDING DOORS (003).pdf PDF
Final CD Single Page 589A5-15-115 Topeka VAMC ED Project FINAL .pdf PDF
1-FA104.pdf PDF
Fire Protection Legacy Drawings B1.pdf PDF
Wage Determination KS20220058 1-7-2022.pdf PDF
SPEC Section 13 05 41 Siesmic Restraint Requirements.pdf PDF
Appendix Asbestos Lead Fungal Reports.pdf PDF
1-FA101.pdf PDF
36C25522R0042 Amendment No.0003 589A5-15-115B ED Phase II.pdf PDF
589A5-15-115 Topeka VAMC ED Project FINAL CDs Full Set 66.pdf PDF
1-FA102.pdf PDF
589A5-15-115B Response II to Bidder RFI.pdf PDF
36C25522R0042 Amendment No.0003 589A5-15-115B ED Phase II.pdf PDF
REVISED 36C25522R0042 589A5-15-115B ED Phase II.pdf PDF
Government Response to RFIs 1 - ED Phase II.pdf PDF
36C25522R0042 Amendment No. 0002 ED Phase II.pdf PDF
Site Visit Attendees - 1-26-2022 - 589A5-15-115B Ed Phase II.pdf PDF
Site Visit Meeting Minutes 1-26-2022 - 589A5-15-115B ED Phase II.pdf PDF
36C25522R0042 Amendment No.0001 589A5-15-115B ED Phase II.pdf PDF
P09 Drawings 589A5-15-115B -2021 Phase II_Part1of4 (40 PGS).pdf PDF
AHU Commissioning Scope 589A5-15-115B ED Phase II.pdf PDF
P09 Drawings 589A5-15-115B - 2021 Phase II Part2of4 (34 PGS).pdf PDF
P09 Drawings 589A5-15-115B -2021 Phase II_Part3of4 (15 PGS).pdf PDF
P07 KS20210058 10-01-2021 589A5-15-115B ED Phase II (1).pdf PDF
P09 Final Specs. Vol. I 589A5-15-115 ED Phase II.pdf PDF
P09 Drawings 589A5-15-115B -2021 Phase II_Part4of4 (16 PGS).pdf PDF
Addendum-No.1 589A5-15-115B ED Phase II.pdf PDF
P09 Final Specs. Vol. II 589A5-15-115 ED Phase II.pdf PDF
Solicitation 36C25522R0042 - 589A5-15-115B ED Phase II.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CC

X3

RR

X11.9

X11.9

X11.8

X9.7X7.4X5.1

X13

U.1

S.4 S.4

Q

X3.9

B

CB/4B

B20B

A

B33E

Z.2

11.710864.73.8

B

B24.2

B

.1

B33E-A

B10A

ELEC

B21

SILVER

RECOVERY

B20

STAIR #6

B9

STAIR #3

B1N

MECHANICAL

B5B

BIOMED

EQUIPMENT

B5A

STORAGE

B6

LOCKER - M

B4

LAUNDRY

B2A

SPECIMEN CL B2B

STORAGE

B2

AUTOPSY

B3

VESTIBULE

B8A

BIOMED STORB7

LOCKER - W

B1M

MECHANICAL

B1B

STAIR #2

B

.1

B44

B43 M

B

B42A

B41 B40

B39

B

B

M .1

B37M.2

B

9 CB/6

B

B

B

.3

B

.2

CB/7

B

B

B12F B13A

B

B

B30

B

B

B

B

B

B

B

B17A

B

B18A

B

B

B

M

B8

C B

/3

CB/4A

CB/6

CORRIDOR

ZZ

B12F

LINEN

B13A

LINEN

B42A

BIOMED

SERVER

B18A

EQUIP STOR

B17A

LINEN

U C

C L1

B15

TSSB14A

EMER SHWR

E X

R G

B12

EXAM

E X

R G

B11

EXAM

CB/5C

HALL

CB/5B

CORRIDOR

CB/4A

CORRIDOR

B33E

ELEC

TR

G

S

B23

WOUND CARE

JA

N

C

B39

HSKP

B38

BREAK ROOM

B40

LOCKER - WB41

LOCKER - M

Z.3 Z.3

Z.4 Z.4

B34

ELEV. EQUIP.

P-3

ELEVATOR

B M

E R

B42

BIOMED

B44

STAIR #10

CB/3

CORRIDOR

B8

STORAGE

E X

R G

B19

EXAM

E X

R G

B18

EXAM

E X

R G

B17

EXAM

M E

D P

B16

MEDS

E X

R G

B14

EXAM

E X

R G

B13

EXAM

R E

C P

B10

REGISTRATION

E X

R G

B29

EXAM

E X

R G

B28

EXAM

E X

R G

B27

EXAM

E X

R G

B26

EXAM

B22M

MECHANICAL

B25

SOILED

HOLDING

B30

CRASH CART

B24

CARE

MANAGERS

CB/7

CORRIDOR

CB/4B

CORRIDOR

B32

TOILET - W

B33

TOILET - M B31

WAITING

B36

TELEPHONE /

DATA

B35

STORAGE

B37E

ELECTRICAL

CB/5A

CORRIDORB37M

MECHANICAL

B43M

MECHANICAL

X13.7

Q.2 Q.2

Q.7

V.5V.5

W.5

XX

YY

Y.9

X11.6

X10X8X4.7X4

X3.8

X2

X1

EE

X12 X14

X14

X15X5 X7 X9

U

X11

N.1

P.1

Q.1 Q.1

R R

O

P

S

T

V

WW

X20

X20

X18

X18

X17X15.1X12.1

X12.1

UP

UP

UP

UP

F

F

TS

30 cd

30 cd

110 cd

F

N A

C

CM

E

WFE

AHU 3

CRAC1

110 cd

110 cd

CM

SD

CM

SD

FACP

F

FNAP

WF

TS

CM

ORDINARY HAZARD GROUP I-RECONFIGURE EXISTING BASE BUILDING

SPRINKLER PIPING AND/OR HEADS WITHIN THIS AREA IN ORDER TO PROVIDE

PROPER COVERAGE PER NFPA 13 . NEW SPRINKLER HEADS TO MATCH EXISTING.

LOCATE HEADS WITHIN ±2" OF CENTER OF TILE. REFER TO REFLECTED CEILING

PLANS FOR COORDINATION WITH LIGHTS, DIFFUSERS, EXIT SIGNS, ETC.

LIGHT HAZARD-RECONFIGURE EXISTING BASE BUILDING SPRINKLER PIPING

AND/OR HEADS WITHIN THIS AREA IN ORDER TO PROVIDE PROPER COVERAGE

PER NFPA 13. NEW SPRINKLER HEADS TO MATCH EXISTING. LOCATE HEADS

WITHIN ±2" OF CENTER OF TILE. REFER TO REFLECTED CEILING PLANS FOR

COORDINATION WITH LIGHTS, DIFFUSERS, EXIT SIGNS, ETC.

ORDINARY HAZARD GROUP II-RECONFIGURE EXISTING BASE BUILDING

SPRINKLER PIPING AND/OR HEADS WITHIN THIS AREA IN ORDER TO PROVIDE

PROPER COVERAGE PER NFPA 13 . NEW SPRINKLER HEADS TO MATCH EXISTING.

LOCATE HEADS WITHIN ±2" OF CENTER OF TILE. REFER TO REFLECTED CEILING

PLANS FOR COORDINATION WITH LIGHTS, DIFFUSERS, EXIT SIGNS, ETC.

FEC

FEC

SD CM

CM

CM

SD

CM

SD

SD

SD

CM

SD CM

CM

SD

SD

MH CG

BASEMENT FLOOR FIRE

PROTECTION PLAN - AREA A

1/8" = 1'-0" Basement Floor Plan1

1-FA103

ARCHITECT:

Drawing Title:

Approved:

CONSULTANTS: Project Title:

Location:

Checked by: Drawn By:Building Number: DRAWING NO.

Revisions: Date

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9

F

E

D

C

B

A o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o h r e e e i g h t h s i n c h o n e f o o n e h a l f i n c h o n e f o o t h r e e q u a r t e r s i n c h o n e f o o t n e i n c h o n e f o o t n e a n d o n e h a l f i n c h e s o n e f o o t t h r e e i n c h e s o n e f o o t

Date:

Scale: HMN Proj. #: 10037.001

Final Construction Documents

Project No.

Misc. Proj. No.

File details come from the government source that posted it. Updated .