Text version
R
J J
J
J J
J
NOT IN SCOPE OF WORK
NOT IN SCOPE OF WORK
E-101
E E E
EEE
E E E
E
E
E E E
E
E
E E E E
EE
E E
E
E
E E
E
E
E
E
E
E E
E
D
D DD
D D
D
D
EEE
E E E E
E E E
EEEE
E
EE
DD
D D
E E E E
E E E
E
E
E
E
EEE
E E
E
E
E E E
EE
P-1-1 P-1-2
CH-1
(TYPICAL ALL 'E'
LIGHT FIXTURES)
(TYPICAL ALL 'D'
LIGHT FIXTURES)
EE
E
PHY. RSCH.
A009A
RSCH. WK. RM.
A010
ENDOCRINE/HYPERTENSION
RSCH.
A019 ENDOCRINE/HYPERTENSION
RSCH.
A020
RSCH. OFFICE
A020A
OFFICE
A022
STAIR #4
A024A
Room A025B
JAN.
A025
ANIMAL WARD
A027A
PATHOGEN FREE SUITE
A026
STAIR CORR.
A024B
CORR.
CBA4
ANIMAL WARD
A027
ANIMAL WARD
A028
ANIMAL WARD
A030
ANIMAL WARD
A032
ANIMAL WARD
A034
ANIMAL WARD
A029
ANIMAL WARD
A031
ANIMAL WARD
A033
ANIMAL WARD
A035
NEURO. SLEEP RSCH.
A023
OFFICE
A023A
STG.
A042A
STG.
A042
SURG. SUITE
A021
VMU OFFICE
A043
NEURO. SLEEP RSCH.
A018
ANIMAL SURG.
A045A
ANIMAL WARD
A045
SHR./LNGE.
A011
COLD. RM.
A014
ANIMAL X-RAY RM.
A015
RADIOPHARMACEUTICAL
SCIENCES RSCH.
A017
DARK ROOM
A015A
ENDOCRINE/HYPERTENSION
RSCH.
A012
RSCH. INVESTIGATOR
A013
RADIOPHARMACEUTICAL
SCIENCES RSCH.
A016
CORR.
CBA6
CORR.
CBA15
CORR.
CBA5
CORR
CBA7
STG. RSCH.
A033A
MECH RM.
A038
CORR
CBA8*
ANIMAL WARD
A039
ANIMAL WARD
A040
CAGE WASH
A041
CART WASH (DIRTY)
A046
CORR.
CBA18
RADIOPHARMACEUTICAL
SCIENCES RSCH.
A047
ELEC. CLOSET
A047A
CORR.
CBA8
M. LKR. RM.
A062B
P.M.I. SHOP
A061
SHR. RM.
A062D
M. ST. LNGE.
A062
F. ST. LNGE.
A063A
M. TLT.
A062C
F. TLT.
A063C
SHR. RM.
A063D
SHR. RM.
A063E
F. LKR. RM.
A063B
SAFETY/EMERGENCY
D005A
CORR.
CBA17
CORR.
CBA11
OFFICE
D005
LAUNDRY & MENDING
D004C
OFFICE
DOO4D
PAINT SHOP
D006
LAUNDRY STORAGE
D055
RADIOPHARMACEUTICAL
SCIENCES RSCH.
A016A
HV-S2
CH-1
E
E E
E
E-101
DEMOLITION PLAN NOTES:
1. DEMOLITION PLANS SHOW THE GENERAL EXTENT OF THE
ELECTRICAL DEMOLITION WORK. THE ELECTRICAL CONTRACTOR
SHALL DISCONNECT ELECTRICAL SERVICES TO ALL EQUIPMENT BEING
REMOVED, SEE MECHANICAL PLANS. OWNER SHALL HAVE THE OPTION
TO RETAIN REUSABLE ITEMS, SUCH AS COVERPLATES, RECEPTACLES,
LIGHTS, PANELS, ETC. NOT BEING USED IN THE FINISHED WORK.
COORDINATE WITH OWNER PRIOR TO STARTING DEMOLITION.
PROPERLY AND LEGALLY DISPOSE OF ALL EQUIPMENT AND MATERIALS
BEING REMOVED.
2. REMOVE ALL CONDUIT LEFT EXPOSED BY REMOVAL OF WALLS AND
CEILINGS IN REMODELED AREAS. PLUG BOTH ENDS OF REMAINING
CONDUIT IN WALL OR FLOOR WHERE CUT.
3. ELECTRICAL OUTLETS, ETC. POSSIBLY CONCEALED BY STORAGE
SHELVING, CASEWORK, FURNITURE, ETC. ARE NOT SHOWN AND
MAY REQUIRE REMOVAL.
4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING
ALL OPENINGS IN EXISTING CONSTRUCTION AFTER REMOVAL OF
EQUIPMENT AND ELECTRICAL DEVICES, ETC.
5. WHERE EQUIPMENT AND OTHER DEVICES ARE BEING REMOVED,
THE CIRCUITING SHALL BE REMOVED, IF POSSIBLE, BACK TO POINT
OF SUPPLY. WHERE REQUIRED, CIRCUITING SHALL BE EXTENDED
TO MAINTAIN CONTINUITY OF THE CIRCUIT OR OPERATION OF THE
SYSTEM.
6. ALL DEVICES SHOWN DASHED ON THE DEMOLITION PLAN(S) SHALL
BE REMOVED, UNLESS NOTED OTHERWISE.
7. PROVIDE MATCHING BLANK COVERPLATES WHERE DEVICES ARE
BEING REMOVED FROM EXISTING WALLS TO REMAIN.
8. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR
TO BEGINNING WORK.
LPB-E4-277VELPB-E4-277VC
LPB-E4-120VC1&2
XFMR
LPB-E4-120VC3
E-101
NOT IN SCOPE OF WORK
NOT IN SCOPE OF WORK
N4N4
N4 N4
E
EE
EE
EE
E
E
E E E E E E
E
E E
EE
E
E
E
E E
E
E
E E E E
EE E
E
EE E
E
EE
E E
EE
E
E
E
E
E E E E
EE
EE
E
EEE
E
E
E
E
E
E E E
EEE
E E E
E
AHU-30
PHY. RSCH.
A009A
RSCH. WK. RM.
A010
ENDOCRINE/HYPERTENSION
RSCH.
A019 ENDOCRINE/HYPERTENSION
RSCH.
A020
RSCH. OFFICE
A020A
OFFICE
A022
STAIR #4
A024A
JAN.
A025
ANIMAL WARD
A027A
PATHOGEN FREE SUITE
A026
STAIR CORR.
A024B
ANIMAL WARD
A027
ANIMAL WARD
A028
ANIMAL WARD
A030
ANIMAL WARD
A032
ANIMAL WARD
A034
ANIMAL WARD
A029
ANIMAL WARD
A031
ANIMAL WARD
A033
ANIMAL WARD
A035
NEURO. SLEEP RSCH.
A023
OFFICE
A023A
STG.
A042A
STG.
A042
SURG. SUITE
A021
VMU OFFICE
A043
NEURO. SLEEP RSCH.
A018
ANIMAL SURG.
A045A
ANIMAL WARD
A045
SHR./LNGE.
A011
COLD. RM.
A014
ANIMAL X-RAY RM.
A015
RADIOPHARMACEUTICAL
SCIENCES RSCH.
A017
DARK ROOM
A015A
ENDOCRINE/HYPERTENSION
RSCH.
A012
RSCH. INVESTIGATOR
A013
RADIOPHARMACEUTICAL
SCIENCES RSCH.
A016
CORR.
CBA6
CORR.
CBA15
CORR.
CBA5
CORR
CBA7
CORR
CBA8*
ANIMAL WARD
A039
ANIMAL WARD
A040CAGE WASH
A041
CART WASH (DIRTY)
A046
CORR.
CBA18
RADIOPHARMACEUTICAL
SCIENCES RSCH.
A047
ELEC. CLOSET
A047A
CORR.
CBA8
P.M.I. SHOP
A061
SHR. RM.
A062D
M. ST. LNGE.
A062
F. ST. LNGE.
A063A
M. TLT.
A062C
F. TLT.
A063C
SHR. RM.
A063D
SHR. RM.
A063E
F. LKR. RM.
A063B
SAFETY/EMERGENCY
D005A
CORR.
CBA17
CORR.
CBA11
OFFICE
D005
LAUNDRY & MENDING
D004C
OFFICE
DOO4D
PAINT SHOP
D006
LAUNDRY STORAGE
D055
RADIOPHARMACEUTICAL
SCIENCES RSCH.
A016A
N4
N4
N4
Room A025B
CORR.
CBA4
MECH RM.
A038
M. LKR. RM.
A062B
CH-1P-1-1
P-1-2
LPB-E4-120VC3:41
LPB-E4-120VC3:39
E E
E
E
E
E
E
E-101
CU-30
(LOCATED ON
LOW ROOF)
ELECTRICAL PLAN NOTES:
1. BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS WITH
INDIVIDUAL NEUTRALS. A MAXIMUM OF THREE CIRCUITS (MAXIMUM OF
THREE PHASE CONDUCTORS) MAY BE GROUPED IN A SINGLE CONDUIT.
WHERE MULTIPLE CIRCUITS ARE LOCATED IN THE SAME RACEWAY,
JUNCTION BOX OR ENCLOSURE, NEUTRALS SHALL BE MARKED OR
LABELED TO INDICATE WHICH CIRCUIT THEY ARE ASSOCIATED WITH.
SEE SPECIFICATION SECTION "LOW VOLTAGE ELECTRICAL POWER
CONDUCTORS AND CABLES" FOR ADDITIONAL INFORMATION.
2. A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN
ALL CONDUITS.
3. FOR CONNECTION REQUIREMENTS TO MECHANICAL UNITS, SEE
MECHANICAL EQUIPMENT CONNECTION SCHEDULE.
4. ALL PENETRATIONS IN THE RATED WALLS AND CEILINGS SHALL BE
SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE
OF FLAMES AND HOT GASSES. THE SEALANT SHALL HAVE A T-RATING
OF ONE HOUR.
5. ALL PIPING, CONDUIT, AND OUTLET BOXES (ELECTRIC, TELEPHONE,
COMPUTER, ETC.) IN THE RATED WALLS OR CEILING SHALL BE
CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL.
6. OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ETC.) SHALL BE
LIMITED TO TWO OUTLET BOXES PER STUD SPACE. OUTLET BOXES ON
OPPOSITE SIDES OF THE RATED WALLS SHALL BE SEPARATED BY A
HORIZONTAL DISTANCE OF 24 INCHES.
7. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT
LIGHT FIXTURE LOCATIONS. VERIFY ALL DISCREPANCIES WITH
ARCHITECT PRIOR TO ROUGH-IN.
EXISTING NORMAL POWER FEEDER: 3 #3/0,
#6 GRD IN 2" CONDUIT SHALL BE CUT,
SPLICED, AND RE-ROUTED AS REQUIRED
IN ORDER TO AVOID CONFLICT WITH
MECHANICAL DUCTWORK.
EXISTING EMERGENCY POWER FEEDER: 3 #1/0,
#6 GRD IN 2" CONDUIT SHALL BE CUT, SPLICED,
AND RE-ROUTED AS REQUIRED IN ORDER TO
AVOID CONFLICT WITH MECHANICAL
DUCTWORK.
AHU-30
PROVIDE AND INSTALL J-BOX WITH DISTRIBUTION
BLOCKS FOR SPLICING AND RE-ROUTING OF EXISTING
FEEDER. RE-ROUTE FEEDER AND CONDUIT AROUND
MECHANICAL DUCTWORK ABOVE OTHER EXISTING
FEEDERS IN THE SPACE AS REQUIRED. (TYPICAL OF 4)
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
E-101
PARTIAL ELECTRICAL FLOOR PLANS
INSTALL ANIMAL RESEARCH AIR HANDLER # 589A4-17-181
06/22/2018 BMW JLW
N.T.S.
BASEMENT KEY PLAN
N
4' 8' 16'
1/8" = 1'-0"
0'
N
1/8" = 1'-0" A
ELECTRICAL LOWER LEVEL DEMOLITION PLAN - PHASE 1A
1/4" = 1'-0"
ENLARGED BASEMENT ELECTRICAL ROOM
N
2' 4' 8'0'
1/4" = 1'-0"
ALL CEILING MOUNTED DEVICES INCLUDING LIGHT
FIXTURES, SPEAKERS, FIRE ALARM DEVICES,
SECURITY DEVICES, WIRELESS ACCESS DEVICES,
ETC. SHALL BE REMOVED AND PROTECTED DURING
CEILING DEMOLITION. ALL DEVICES SHALL BE
INSTALLED BACK INTO CEILING IN THE SAME PLACE.
VERIFY EXTENT OF CEILING DEMOLITION WITH
ARCHITECTURAL PLANS PRIOR TO BID.
N
4' 8' 16'
1/8" = 1'-0"
0'
1/8" = 1'-0" B
ELECTRICAL LOWER LEVEL FLOOR PLAN - PHASE 1A
1/4" = 1'-0"
EXISTING CONDUIT RELOCATION PLAN
KEYED NOTES:
1 REMOVE CONNECTION TO EXISTING MECHANICAL EQUIPMENT AND
ASSOCIATED DISCONNECTING MEANS, CONDUIT, AND CABLING. MAINTAIN
CONTINUITY OF EXISTING CIRCUITING WHICH SERVES MECHANICAL
EQUIPMENT NOT BEING REMOVED AS REQUIRED.
2 ALL EXISTING LIGHT FIXTURES LOCATED IN A CEILING BEING REMOVED ARE
TO BE REMOVED DURING CEILING DEMOLITION. STORE/PROTECT LIGHT
FIXTURES DURING CONSTRUCTION, AND RE-INSTALL FIXTURES IN NEW
CEILING IN EXACT SAME PLACE. ALL EXISTING CONDUIT AND CIRCUITING TO
REMAIN.
3 EXISTING LIGHT FIXTURE AND ASSOCIATED CONDUIT AND CIRCUITING TO BE
REMOVED.
4 CONNECT TO EXISTING 277V LIGHTING CIRCUIT WHICH SERVES EXISTING
SPACE.
6 VFD AND FIRE ALARM SHUT DOWN RELAY LOCATION FOR MECHANICAL
EQUIPMENT 'AHU-30'. REFERENCE MECHANICAL EQUIPMENT CONNECTION
SCHEDULE FOR ADDITIONAL INFORMATION.
7 J-BOX MOUNTED ABOVE ACCESSIBLE CEILING FOR CONNECTION TO
MECHANICAL EQUIPMENT LOW VOLTAGE TRANSFORMERS PROVIDED AND
INSTALLED BY TEMPERATURE CONTROLS CONTRACTOR. COORDINATE
LOCATION AND NUMBER OF LOW VOLTAGE TRANSFORMERS WITH TCC.
8 1.5 KVA, 120V. SINGLE PHASE UPS MOUNTED ON THE WALL IMMEDIATELY
BELOW THE CONTROLS CABINET. INTERCEPT EXISTING 120V. CIRCUIT
WHICH POWERS THE CONTROLS CABINET AND ROUTE CIRCUIT THROUGH
UPS PRIOR TO RE-CONNECTING TO THE CONTROLS CABINET. VERIFY ALL
REQUIREMENTS PRIOR TO INSTALLATION.
9 INTERLOCK OCCUPANCY SENSORS AS REQUIRED.
N
2' 4' 8'0'
1/4" = 1'-0"
N
2' 4' 8'0'
1/4" = 1'-0" 1/4" = 1'-0"
CONDUIT RELOCATION PLAN
ADDENDUM 1 8/22/2018
| Sheets |
| E-001 - ELECTRICAL SYMBOLS AND SCHEDULES |
| E-101 - PARTIAL ELECTRICAL FLOOR PLANS |
File details come from the government source that posted it.