36C25218B0066-005.pdf
PDF 2 MB Posted
- Solicitation number
- 36C25218B0066
About this file
36C25218B0066 S02 171004_MILVA_RTU102_100Drawings_1of7.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25218C0056-000.docx | DOCX document | |
| 36C25218B0066-00003001.pdf | ||
| 36C25218B0066-00003000.docx | DOCX document | |
| 36C25218B0066-00002001.pdf | ||
| 36C25218B0066-00002000.docx | DOCX document | |
| 36C25218B0066-012.docx | DOCX document | |
| 36C25218B0066-00001002.pdf | ||
| 36C25218B0066-00001001.pdf | ||
| 36C25218B0066-00001004.pdf | ||
| 36C25218B0066-00001003.pdf | ||
| 36C25218B0066-00001000.docx | DOCX document | |
| 36C25218B0066-006.pdf | ||
| 36C25218B0066-004.pdf | ||
| 36C25218B0066-010.pdf | ||
| 36C25218B0066-002.pdf | ||
| 36C25218B0066-011.pdf | ||
| 36C25218B0066-003.pdf | ||
| 36C25218B0066-001.docx | DOCX document | |
| 36C25218B0066-007.pdf | ||
| 36C25218B0066-009.pdf | ||
| 36C25218B0066-008.pdf | ||
| 36C25218B0066-000.docx | DOCX document |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON DESIGN INC.
905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204
317.800.6388 | WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
NON-SPRINKLERED
BLDG 102
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
AE
In st al l E M
S\ 2.
D ra w in gs \2
-1 _A rc hi te ct ur e\
1- 1_
R ev it\
.1
6.
M ilV
A R
TU
R ep la ce m en t B ui ld in g v1 6.
rv t
9/
/2
:5 9:
P
M
GI000
COVER SHEET
RING & DuCHATEAU LLP
17400 W. CAPITOL DRIVE
BROOKFIELD, WI 53045
(414) 778-1700
INSTALL EMS BUILDING 102
MILWAUKEE VAMC
695-17-108
24 JULY 2017 ETA JP
100% CONSTRUCTION
DOCUMENTS
MILWAUKEE VA
CLEMENT J. ZABLOCKI VA MEDICAL CENTER
INSTALL ENVIRONMENTAL MONITORING SYSTEMS
IN STERILE AND CLEAN SUPPLY ROOMS
(REPLACE RTU BUILDING 102)
100% CONSTRUCTION DOCUMENTS
SHEET LIST
SHEET NUMBER SHEET NAME
GENERAL
GI000 COVER SHEET
GI101 LIFE SAFETY PLAN
GI102 LIFE SAFETY PLAN
GI103 INFECTION CONTROL/PHASING PLAN
ARCHITECTURAL
AS001 ARCHITECTURAL SYMBOLS AND ABBREVIATIONS
AS101 FLOOR PLANS
AS102 REFLECTED CEILING PLANS
AS501 DETAILS
MECHANICAL
MI000 MECHANICAL GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
MH100 SECOND FLOOR AND HIGH ROOF PLANS - MECHANICAL
MM500 MECHANICAL DETAILS AND SCHEDULES
MM501 CONTROLS DIAGRAMS
ELECTRICAL
ES000 ELECTRICAL SYMBOLS, ABBREVIATIONS AND SHEET INDEX
ES010 SITE ELECTRICAL PLAN
ED100 BASEMENT FLOOR PLAN - ELECTRICAL DEMOLITION
ED103 HIGH ROOF PLAN - ELECTRICAL DEMOLITION
ES100 BASEMENT FLOOR PLAN - ELECTRICAL
ES101 FIRST FLOOR PLAN - ELECTRICAL
ES102 SECOND FLOOR PLAN - ELECTRICAL
ES103 HIGH ROOF PLAN - ELECTRICAL
ES400 ONE-LINE SYMBOLS AND ABBREVIATIONS
ES401 ONE-LINE DIAGRAM
ES402 ONE-LINE DIAGRAM
ES500 ELECTRICAL DETAILS
ES600 ELECTRICAL SCHEDULES
Contact:
RING & DUCHATEAU, LLP
Michael Jushka Professional Engineer
MECHANICAL,
ELECTRICAL &
PLUMBING
OWNER ARCHITECT
17400 West Capitol Drive Brookfield, WI 53045 p: 414.778.7414 e: mjushka@ringdu.com
LOCATION MAP
LOCATION MAP
N
N
SPS BUILDING 102
BUILDING 102
Contact: Contact:
CLEMENT J. ZABLOCKI
VA MEDICAL CENTER
Milwaukee VAMC
5000 West National Ave.
Milwaukee, WI 53295 p: 414.384.2000
GUIDON DESIGN INC.
Evan Anderson-Decina, AIA Project Manager | Architect
905 North Capitol Avenue Suite 100 Indianapolis, IN 46204 p: 317.800.6388 x 116 e: edecina@guidondesign.com
PROJECT NO: 695-17-108
NOTE:
IN THE CASE OF CONFLICTS OR DISCREPANCIES
WITHIN OR AMONG THE CONTRACT DRAWINGS, THE
BETTER QUALITY, MORE STRINGENT REQUIREMENTS
OR GREATER QUANTITY OF WORK, AS DETERMINED
BY THE GOVERNMENT, SHALL BE PROVIDED.
THE PROJECT SCOPE INCLUDES THE REMOVAL OF THE EXISTING ROOFTOP UNIT FROM THE HIGH ROOF OF BUILDING 102 THAT CURRENTLY SERVES THE SECOND FLOOR RECEIVING AREA. A NEW DX COOLING ROOFTOP UNIT (AHU-135-2) WILL BE INSTALLED ON THE HIGH ROOF THAT WILL PROVIDE BOTH COOLING TO THE SECOND FLOOR RECEIVING AREA, AND ALSO SUPPLEMENT EXISTING UNIT AHU-135-1. THE PROJECT WILL
INCLUDE REPLACEMENT OF THE EXISTING BUILDING TRANSFORMER TO ACCOMMODATE THE NEW
ELECTRICAL LOADING REQUIREMENTS OF THE NEW ROOF TOP UNIT. THE PROJECT SCOPE INCLUDES ALL ASSOCIATED REPAIR WORK, ROOF TOP UNIT CONTROLS, CONNECTING DUCTWORK, UTILITY CONNECTIONS
AND SYSTEM TIE-INS TO ACTIVATE THE NEW AHU-135-2.
PROJECT DESCRIPTION
Revisions: Date:
8"
88'-0"
45'-10"
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A
B
C
D
A
B
C
D
E E
IT
ROOM
CHILLER
MECHANICAL
CORRIDOR
ELECTRIC
MECH.
SPRINKLER
SERV. ROOM
B100FC
B100
B110
B115
B120
B125
B100FP
T.T.
T.
T.
T.
T.
C .U .H . H .W
PI
PI
NG
REQ'D
FLOOR CLR.
REQ'D
FLOOR CLR.
REQ'D
FLOOR CLR.
REQ'D
FLOOR CLR.
RAMP DOWN
ST
AI
R
DO
W N
STAIR UP
ST
AI
R
DO
W N
RAMP DOWN
SLOPE 1:12
SLOPE 1:12
STAIR DOWN
ST
AI
R
DO
W N
ST
AI
R
DO
W N
STAIR UP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A
B
C
D
A
B
C
D
E E
161'-6"
175'-6"
132'-8"
197'-6"
178'-6"
156'-6"
220'-0"
221'-6"
110'-0"
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
SHARED
OFFICE
CART
WASH
ANTE
PPE
LOCKER
LOCKER
TLT &
SHOWER
TLT &
SHOWER
STAFF
CONF
ANTE
PPE
TLT &
SHOWER
LOCKER
TLT &
SHOWER
LOCKER
HAC
WATER &
DETERGENT
ENDOSCOPE
PROCESSING
HIGH LEVEL
DISINFECTION
SCOPE
STORAGE
CLEAN RECEIVING
& BREAK OUT
DISPATCH
BULK
STORAGE
PREP, ASSEMBLY
& STERILIZATION
SOILED RECEIVING
& DECONTAMINATION
SOILED
RECEIVING
STERILE / NON-STERILE
STORAGE
ANTE
CLEAN CART
HOLDING
OFFICE
OFFICE
EQUP STORAGE
& TESTING
HAC
PA
SS
AG
E
OFFICE
PASSAGE
STEAM
STERILIZERS
AERATOR
ETO
PASSAGE
CLEAN
DELIVERIES
UNASSIGNED
TRAINING
ROOM
HAC
EMS
PACKING
SHIPPING
TRAINING
ROOM
LINEN
STORAGE
LINEN
STORAGE
IT
ROOM
SERVICE
166A
165A
171 174
176A
175A
102HC
112 116114 116A
121HC
M1
161A
M102 M102A
151HC
100A
150A
100FC
M101
CODE ANALYSIS LEGEND
TOTAL OCCUPANCY
FEC
EXIT
OCCUPANCY LOAD FACTOR
EXITS REQUIRED
SQUARE FOOTAGE
OCCUPANCY TYPE
EGRESS EXIT SIGNAGE
FIRE EXTINGUISHER CABINET
DIAGONAL DISTANCE
EXIT SEPARATION DISTANCE
EGRESS PATH
B
1500 SF
100 1
REFER TO VA MANUAL PG-18-3 FOR ADDITIONAL CODES, STANDARDS, GUIDELINES AND
REGULATIONS, BELOW LISTING IS NOT COMPREHENSIVE.
ICC, INTERNATIONAL BUILDING CODES, 2015 EDITION (IBC)
ASCE-07-10
ACI 318-11
ACI 530-11
AISC 341-10
AISC 360-10
PCI MNL 120-10, DESIGN HANDBOOK
NFPA 70, NATIONAL ELECTRICAL CODE, 2017 EDITION
NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2016 EDITION
NFPA 80, STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2016 EDITION
NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING
SYSTEMS, 2015 EDITION.
NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS, 2015 EDITION
NFPA 99, HEALTH CARE FACILITIES, 2015 EDITION
NFPA 101, LIFE SAFETY CODE, 2015 EDITION
NFPA 110, STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS, 2016 EDITION
NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION, 2015 EDITION
NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION AND DEMOLITION
OPERATIONS, 2013 EDITION
MOST RECENT EDITION OF NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000
AND NFPA 900
ASHRAE 90.1-2016 HVAC SYSTEMS
ASHRAE 62.1 - 2016 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY
ASHRAE 1.1 - 2007 HVAC & R TECHNICAL REQUIREMENTS FOR COMMISSIONING PROCESS
ASHRAE 55- 2013 THERMAL ENVIRONMENTAL CONDITIONS FOR HUMAN OCCUPANCY
ANSI A117.1-2009 STANDARD ON ACCESSIBLE & USABLE BUILDINGS AND FACILITIES
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS
ENERGY POLICY ACT OF 2005 (EPACT)
EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY, AND
TRANSPORTATION MANAGEMENT.
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD
STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
VA BARRIER FREE DESIGN GUIDE PG-18-13, ABAAS
ARCHITECTURAL, AUGUST 1, 2014
ASBESTOS ABATEMENT, JULY 2011
CMP SCHEDULE AND RISK MANAGEMENT, VOL. 1 & 2, DECEMBER 2012
ELECTRICAL, DECEMBER 2015
ENERGY SUSTAINABILITY, MAY 2014
EQUIPMENT, JANUARY 2006
ESTIMATING, MARCH 8, 2011
NFPA INTERIM GUIDANCE FOR PROJECTS, PG-18-17, SEPTEMBER 30, 2010
FIRE PROTECTION, SEVENTH EDITION REVISED DECEMBER 2015
HVAC FOR NEW, REPLACEMENT, ADD. AND REN. OF EXIST. CA FACILITIES, MARCH 2011
PHYSICAL SECURITY DESIGN MANUAL, JANUARY 2015
PLUMBING, NOVEMBER 2014
STRUCTURAL, FEBRUARY 1, 2014
ENVIRONMENTAL PLANNING GUIDANCE PG-18-17 NEPA INTERIM GUIDELINES FOR
PROJECTS SEPTEMBER 30, 2010
EPA GUIDELINES CHECKLIST
VA DESIGN MANUALS PG-18-10:
GOVERNING CODES:
EXISTING BUILDING 102 SUMMARY
CODE CRITERIA
GENERAL: THIS SUMMARY OF CODE REQUIREMENTS IS BASED PRIMARILY ON NFPA 101
(LSC). DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED
THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC
OR AS OTHERWISE IDENTIFIED. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH
THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE
REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE
USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO
LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS,
BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY
HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC
HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES.
NOTES:
CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA
REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA
ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE
BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE
MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY
SYSTEM WIDE.
CODE REVIEW
THE 2015 EDITION OF THE LIFE SAFETY CODE, NFPA 101, HAS BEEN USED TO REVIEW THIS
PROJECT FOR COMPLIANCE WITH THE FIRE AND LIFE SAFETY REQUIREMENTS. FOR
FEATURES NOT ADDRESSED BY NFPA 101 AND THE REFERENCED NATIONAL FIRE CODES,
THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE HAS BEEN USED.
PROJECT SCOPE
THE PROJECT SCOPE INCLUDES REPACING AN EXISTING ROOF TOP UNIT WITH A NEW,
LARGER ROOF TOP UNIT TO BETTER PROVIDE HEATING AND COOLING TO THE BUILDING.
NO ELEMENTS OF THE BUILDING'S EGRESS, STRUCTURE OR RATINGS ARE BEING
ALTERED AS PART OF THIS SCOPE.
EXISTING BUILDING 102
BASEMENT FLOOR: 4,000 GSF
FIRST FLOOR: 21,040 GSF
SECOND FLOOR: 4,000 GSF
TOTAL EXISTING BUILDING: 29,040 GSF
TOTAL ALLOWABLE AREA PER FLOOR: 23,000 GSF (LSC Table 7.4.1)
EXISTING BUILDING:
TYPE II (000) STEEL FRAME PROTECTED
STRUCTURAL FRAME (0) HOURS
BEARING WALLS (0) HOURS
NON-BEARING WALLS (0) HOURS
FLOOR (0) HOURS
BEAMS (0) HOURS
COLUMNS (0) HOURS
ROOF (0) HOURS
EXISTING OCCUPANCY: BUSINESS
EQUIPPED THROUGHOUT WITH A COMPLIANT AUTOMATIC SPRINKLER PER NFPA 13
NOT IN SCOPE
2HR RATED WALL
NOTE: NO CHANGE IN EGRESS ELEMENTS
NOTE: NO CHANGE IN EGRESS ELEMENTS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON DESIGN INC.
905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204
317.800.6388 | WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
NON-SPRINKLERED
BLDG 102
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
AE
In st al l E M
S\ 2.
D ra w in gs \2
-1 _A rc hi te ct ur e\
1- 1_
R ev it\
.1
6.
M ilV
A R
TU
R ep la ce m en t B ui ld in g v1 6.
rv t
9/
/2
:5 6:
P
M
GI101
LIFE SAFETY PLAN
RING & DuCHATEAU LLP
17400 W. CAPITOL DRIVE
BROOKFIELD, WI 53045
(414) 778-1700
INSTALL EMS BUILDING 102
MILWAUKEE VAMC
695-17-108
24 JULY 2017 ETA JP
100% CONSTRUCTION
DOCUMENTS
MILWAUKEE VA
N
0' 4' 8' 20'
SCALE: 3/32" = 1'-0"GI101
1 BASEMENT LIFE SAFETY PLAN
SCALE: 3/32" = 1'-0"GI101
2 FIRST FLOOR LIFE SAFETY PLAN
0' 4' 8' 20'
N
ROOF PITCH
ROOF PITCH
ROOF PITCH
ROOF PITCH
D.S.
D.S.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A
B
C
D
A
B
C
D
E E
DN
UP
CODE ANALYSIS LEGEND
TOTAL OCCUPANCY
FEC
EXIT
OCCUPANCY LOAD FACTOR
EXITS REQUIRED
SQUARE FOOTAGE
OCCUPANCY TYPE
EGRESS EXIT SIGNAGE
FIRE EXTINGUISHER CABINET
DIAGONAL DISTANCE
EXIT SEPARATION DISTANCE
EGRESS PATH
B
1500 SF
100 1
REFER TO VA MANUAL PG-18-3 FOR ADDITIONAL CODES, STANDARDS, GUIDELINES AND
REGULATIONS, BELOW LISTING IS NOT COMPREHENSIVE.
ICC, INTERNATIONAL BUILDING CODES, 2015 EDITION (IBC)
ASCE-07-10
ACI 318-11
ACI 530-11
AISC 341-10
AISC 360-10
PCI MNL 120-10, DESIGN HANDBOOK
NFPA 70, NATIONAL ELECTRICAL CODE, 2017 EDITION
NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2016 EDITION
NFPA 80, STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2016 EDITION
NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING
SYSTEMS, 2015 EDITION.
NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS, 2015 EDITION
NFPA 99, HEALTH CARE FACILITIES, 2015 EDITION
NFPA 101, LIFE SAFETY CODE, 2015 EDITION
NFPA 110, STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS, 2016 EDITION
NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION, 2015 EDITION
NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION AND DEMOLITION
OPERATIONS, 2013 EDITION
MOST RECENT EDITION OF NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000
AND NFPA 900
ASHRAE 90.1-2016 HVAC SYSTEMS
ASHRAE 62.1 - 2016 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY
ASHRAE 1.1 - 2007 HVAC & R TECHNICAL REQUIREMENTS FOR COMMISSIONING PROCESS
ASHRAE 55- 2013 THERMAL ENVIRONMENTAL CONDITIONS FOR HUMAN OCCUPANCY
ANSI A117.1-2009 STANDARD ON ACCESSIBLE & USABLE BUILDINGS AND FACILITIES
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS
ENERGY POLICY ACT OF 2005 (EPACT)
EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY, AND
TRANSPORTATION MANAGEMENT.
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD
STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
VA BARRIER FREE DESIGN GUIDE PG-18-13, ABAAS
ARCHITECTURAL, AUGUST 1, 2014
ASBESTOS ABATEMENT, JULY 2011
CMP SCHEDULE AND RISK MANAGEMENT, VOL. 1 & 2, DECEMBER 2012
ELECTRICAL, DECEMBER 2015
ENERGY SUSTAINABILITY, MAY 2014
EQUIPMENT, JANUARY 2006
ESTIMATING, MARCH 8, 2011
NFPA INTERIM GUIDANCE FOR PROJECTS, PG-18-17, SEPTEMBER 30, 2010
FIRE PROTECTION, SEVENTH EDITION REVISED DECEMBER 2015
HVAC FOR NEW, REPLACEMENT, ADD. AND REN. OF EXIST. CA FACILITIES, MARCH 2011
PHYSICAL SECURITY DESIGN MANUAL, JANUARY 2015
PLUMBING, NOVEMBER 2014
STRUCTURAL, FEBRUARY 1, 2014
ENVIRONMENTAL PLANNING GUIDANCE PG-18-17 NEPA INTERIM GUIDELINES FOR
PROJECTS SEPTEMBER 30, 2010
EPA GUIDELINES CHECKLIST
VA DESIGN MANUALS PG-18-10:
GOVERNING CODES:
EXISTING BUILDING 102 SUMMARY
CODE CRITERIA
GENERAL: THIS SUMMARY OF CODE REQUIREMENTS IS BASED PRIMARILY ON NFPA 101
(LSC). DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED
THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC
OR AS OTHERWISE IDENTIFIED. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH
THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE
REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE
USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO
LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS,
BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY
HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC
HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES.
NOTES:
CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA
REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA
ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE
BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE
MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY
SYSTEM WIDE.
CODE REVIEW
THE 2015 EDITION OF THE LIFE SAFETY CODE, NFPA 101, HAS BEEN USED TO REVIEW THIS
PROJECT FOR COMPLIANCE WITH THE FIRE AND LIFE SAFETY REQUIREMENTS. FOR
FEATURES NOT ADDRESSED BY NFPA 101 AND THE REFERENCED NATIONAL FIRE CODES,
THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE HAS BEEN USED.
PROJECT SCOPE
THE PROJECT SCOPE INCLUDES REPACING AN EXISTING ROOF TOP UNIT WITH A NEW,
LARGER ROOF TOP UNIT TO BETTER PROVIDE HEATING AND COOLING TO THE BUILDING.
NO ELEMENTS OF THE BUILDING'S EGRESS, STRUCTURE OR RATINGS ARE BEING
ALTERED AS PART OF THIS SCOPE.
EXISTING BUILDING 102
BASEMENT FLOOR: 4,000 GSF
FIRST FLOOR: 21,040 GSF
SECOND FLOOR: 4,000 GSF
TOTAL EXISTING BUILDING: 29,040 GSF
TOTAL ALLOWABLE AREA PER FLOOR: 23,000 GSF (LSC Table 7.4.1)
EXISTING BUILDING:
TYPE II (000) STEEL FRAME PROTECTED
STRUCTURAL FRAME (0) HOURS
BEARING WALLS (0) HOURS
NON-BEARING WALLS (0) HOURS
FLOOR (0) HOURS
BEAMS (0) HOURS
COLUMNS (0) HOURS
ROOF (0) HOURS
EXISTING OCCUPANCY: BUSINESS
EQUIPPED THROUGHOUT WITH A COMPLIANT AUTOMATIC SPRINKLER PER NFPA 13
NOT IN SCOPE
2HR RATED WALL
DIAGONAL DISTANCE: 92' - 0"
MA
X
TR
AV
EL
D
IS
TA
NC
E:
9"
EXIT
MAX TRAVEL DISTANCE: 43' - 0"
3068 SF
10031 B
565 SF
B
STAIR
S1
ELEV
E1
EXISTING RECEIVING
EXISTING RECEIVING
NOTE: NO CHANGE IN EGRESS ELEMENTS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON DESIGN INC.
905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204
317.800.6388 | WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
NON-SPRINKLERED
BLDG 102
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
AE
In st al l E M
S\ 2.
D ra w in gs \2
-1 _A rc hi te ct ur e\
1- 1_
R ev it\
.1
6.
M ilV
A R
TU
R ep la ce m en t B ui ld in g v1 6.
rv t
/3
/2
:4 6:
P
M
GI102
LIFE SAFETY PLAN
RING & DuCHATEAU LLP
17400 W. CAPITOL DRIVE
BROOKFIELD, WI 53045
(414) 778-1700
INSTALL EMS BUILDING 102
MILWAUKEE VAMC
695-17-108
24 JULY 2017 ETA JP
100% CONSTRUCTION
DOCUMENTS
MILWAUKEE VA
N
0' 4' 8' 16'
SCALE: 1/8" = 1'-0"GI102
1 SECOND FLOOR LIFE SAFETY PLAN
DN
DN
C .U .H . H .W
PI
PI
NG
STAIR UP
ST
AI
R
DO
W N
STAIR DOWN
ST
AI
R
DO
W N
STAIR UP
FD
ANTE
PPE
CLEAN RECEIVING
& BREAK OUT
DISPATCH
BULK
STORAGE
ANTE
CLEAN CART
HOLDING
PASSAGE
CLEAN
DELIVERIES
UNASSIGNED
HAC
EMS
PACKING
SHIPPING
LINEN
STORAGE
151HC
150A
C .U .H . H .W
PI
PI
NG
STAIR UP
ST
AI
R
DO
W N
STAIR DOWN
ST
AI
R
DO
W N
STAIR UP
175'-6"
132'-8"
FD
ANTE
PPE
CLEAN RECEIVING
& BREAK OUT
DISPATCH
BULK
STORAGE
ANTE
CLEAN CART
HOLDING
PASSAGE
CLEAN
DELIVERIES
UNASSIGNED
HAC
EMS
PACKING
SHIPPING
LINEN
STORAGE
151HC
150A
AREA
WELL
ELEV
EQUIP
UNEXCAVATED
SPACE
AREA
WELL
ELEV
STAIR
B130
S1
IT
ROOM
CHILLER
MECHANICAL
CORRIDOR
ELECTRIC
MECH.
SPRINKLER
SERV. ROOM
B100FC
B100
B110
B115
B120
B125
B100FP
IT
ROOM
CHILLER
MECHANICAL
CORRIDOR
ELECTRIC
MECH.
SPRINKLER
SERV. ROOM
B100FC
B100
B110
B115
B120
B125
B100FP
INFECTION CONTROL PLAN NOTES #
INFECTION CONTROL PROJECT INFORMATION
CONSTRUCTION ACTIVITY - FIRE RISK: TYPE C
PATIENT RISK GROUP: LOW
CLASS OF PRECAUTION MATRIX: II
PROVIDE TEMPORARY POLYETHYLENE CONSTRUCTION BARRIER. REFER TO
SPECIFICATION FOR ADDITIONAL INFORMATION.
PROVIDE TEMPORARY POLYETHYLENE BARRIER OVER DOOR AND SEAL WITH TAPE.
WORK IN THIS AREA TO OCCUR IN 2 DAYS PERIOD OVER ONE WEEKEND AS THIS
WORK CREATES DEAD END CORRIDORS.
1.
2.
3.
REFER TO LIST OF REQUIRED INFECTION CONTROL PRECAUTIONS OUTLINED
BY CLASS IN SPECIFICATION 010110.
REFER TO DRAWINGS, SPECIFICATIONS AND DOOR HARDWARE SCHEDULE
FOR ADDITIONAL INFORMATION.
COORDINATE FULL SCOPE OF WORK WITH ENGINEERING DRAWINGS AND
FIELD VERIFICATION. CONTRACTOR IS RESPONSIBLE FOR SCOPE OF ABOVE
CEILING WORK REQUIRED ABOVE AND BELOW THE FLOOR PLATE OF THE
PROJECT BOUNDARY.
COORDINATE LOCATION OF TEMPORARY INFECTION CONTROL (IC) BARRIER
WALL CONSTRUCTION AND INFECTION CONTROL (IC) MEASURES WITH COR
AND PATIENT SAFETY/ INFECTION CONTROL REPRESENTATIVE. TEMPORARY
IC BARRIER WALL CONSTRUCTION LOCATIONS IN DRAWINGS ARE
APPROXIMATE. CONTRACTOR SHALL PROVIDE DRAWING TO COR AND
PATIENT SAFETY/ INFECTION CONTROL REPRESENTATIVE ONCE ICRA
PROTOCOLS AND PLAN IS APPROVED.
SCHEDULE AND TIME OF CONSTRUCTION WORK TO BE APPROVED BY COR
BEFORE CONSTRUCTION MAY BEGIN. PROVIDE PHASING INFORMATION FOR
ABOVE CEILING WORK IN THE CONTRACTOR PROVIDED CMP SCHEDULE FOR
WORK ALSO REQUIRED ABOVE AND BELOW THE FLOOR PLATE OF THE
PROJECT BOUNDARY.
EXIT/ACCESS FOR ADJACENT OPERATIONAL AREAS SHALL BE MAINTAINED
DURING NORMAL BUSINESS HOURS. SEE SPECIFICATION FOR HOURS OF
OPERATION.
PROVIDE THE FOLLOWING INFECTION CONTROL MEASURES, A 24"X36" STICKY
WALK OFF MAT AND HAND SANITIZER AT EACH TEMPORARY DOOR LOCATION.
MAT SHALL BE REPLACED OR CLEANED AS NECESSARY
PROVIDE THE VA AND OSHA REQUIRED TEMPORARY SIGNAGE AT EACH
TEMPORARY DOOR LOCATION.
CONTRACTOR SHALL SUPPLY SPILL KIT. SPILL KIT TO INCLUDE SHOP VAC,
MULTI-PURPOSE SPILL CONTROL SORBENTS TO ABSORB NON AGGRESSIVE
LIQUIDS UP TO 30 GALLONS.
ALL NEW MATERIAL MOVED THROUGH THE FACILITY SHALL BE COVERED
WITH 4 MIL. POLY SHEET.
ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE PROJECT
BOUNDARY THROUGH THE FACILITY TO DUMPSTER ALONG VA APPROVED
ROUTE IN ENCLOSED DUMPSTER CART DESIGNED FOR SUCH PURPOSED
WITH A LID.
ALL MATERIAL, DEBRIS AND HAZARDOUS MATERIALS SHALL BE PROPERLY
STORED IN DESIGNATED AREAS AND APPROVED CONTAINERS. FLAMMABLE
MATERIALS SHALL NOT BE STORED IN THE FACILITY.
PROVIDE CONTAINMENT CART FOR ABOVE CEILING ACCESS OUTSIDE
PROJECT BOUNDARY.
PROVIDE FILTER MEDIA OVER THE AIR INTAKE OF AHU-135-1 DURING
CONSTRUCTION ACTIVITIES AS TO LIMIT CONTAMINENT INFILTIRATION WHILE
MAINTAINING OPTIMUM PERFORMANCE OF SYSTEM. WHEN CONSTRUCTION
ACTIVITIES ARE AT A MINIMUM, REMOVE FILTER MEDIA AS DIRECTED BY COR.
FILTER MEDIA TO BE MERV 7 OR 8.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
INFECTION CONTROL GENERAL NOTES
PHASING GENERAL NOTES #
A REFER TO SPECIFICATION 01 00 00 FOR INFORMATION ON WORK DURATION FOR
EACH PHASE AND AREA OF WORK.
ELECTRICAL SEQUENCE: REFER TO SPECIFICATION 26 05 05 FOR MORE DETAILED
REQUIREMENTS
PERFORM TRANSFORMER REPLACEMENT ON A SATURDAY. WORK OCCURING
FOR REPLACEMENT TO OCCUR WITHIN 18 HOURS TO REDUCE REQUIRED
SHUTDOWN. WHILE THIS WORK IS OCCURING, EXISTING BUILDING GENERATOR
WILL SERVICE BUILDING.
CONTRACTOR TO COORDINATE WITH COR SCHEDULE OF THIS WEEKEND SO
GENERATOR CAN BE TESTED PRIOR TO WORK.
EXISTING CONCRETE PAD FOR TRANSFORMER IS TO BE EXTENDED. THIS WORK
SHOULD OCCUR IN ADVANCE TO ENSURE NEW PAD IS READY FOR NEW
TRANSFORMER PLACEMENT AND HAS ADEQUATE TIME TO CURE.
TEST NEW TRANSFORMER.
INSTALL CONDUIT FOR AHU-135-2 FEEDER AND INSTALL MOTOR STARTER AND
WIRE.
ENSURE TEMPORARY GENERATOR IS FULL AND HAS BEEN TESTED. SWITCH
BUILDING TO TEMPORARY GENERATOR.
INSTALL NEW TRANSFORMER, CONDUCTORS, LUGS, NEW BREAKERS,
SWITCHBOARD SECTIONS, BUS EXTENSIONS.
RESTORE BUILDING TO NORMAL POWER FROM TEMPROARY POWER.
DISCONNECT LUGS AND CONDUCTORS. REMOVE TRANSOFRMER FROM PAD AND
RETURN TO VA.
HVAC SEQUENCE:
PERFORM ALL HVAC WORK AS INDICATED IN DRAWINGS AND SPECIFICATIONS.
INSTALL NEW INTAKE DUCTWORK FOR EXISTING AHU-135-1 BY REMOVING
EXISTING OUTSIDE AIR INTAKE HOOD AND INSTALLING NEW INTAKE DUCT
ARRANGEMENT WITH DAMPERS.
REMOVE EXISTING ROOF EXHAUST FAN.
INSTALL ALL NEW DUCTWORK ON ROOF.
INSTALL CURBING AND PERFORM ROOF REPAIRS FOR INSTALLATION OF NEW
AHU-135-2 AND RELIEF FAN RLF-135.
LIFT NEW AHU-135-2 ONTO ROOF, SET AND TEST.
REMOVE EXISTING ROOFTOP AC UNIT AS INDICATED ON DRAWINGS AND
COMPLETE INSTALLATION OF SUPPLY AND RETURN AIR TO STORAGE AREA.
CONTRACTOR TO COORDINATE THIS WORK TO MINIMIZE INSTALLATION TIME
AFTER EXISTING RTU IS REMOVE. CONTRACTOR TO PERFORM WORK SO THAT
SECOND FLOOR AREA IS UNCONDITIONED FOR NO MORE THAN 24 HOURS.
CONTRACTOR TO COORDINATE WITH COR SCHEDULE OF THIS EVENT TO ENSURE
MINIMIAL SHUTDOWN TIME IS REQUIRED.
TESTING OF NEW AHU-135-2 HAS TO OCCUR AFTER NEW TRANSFORMER HAS
BEEN INSTALLED. SEE ELECTRICAL SEQUENCING.
PROJECT PHASING AND SEQUENCING
1.
2.
3.
4.
5.
6.
7.
1.
2.
3.
4.
5.
6.
7.
IC/PHASING LEGEND
TEMPORARY WALLS. SEE PLAN AND
PLAN NOTES
TEMPORARY CONSTRUCTION ACCESS
DOORS
REFERENCE AREA FOR ABOVE
CEILING WORK ON FLOOR BELOW.
REFER TO ENGINEERING DRAWINGS
FOR FULL SCOPE OF WORK
BEYOND PROJECT BOUNDARY
PROJECT BOUNDARY
EXISTING RECEIVING
ELEV
E1
STAIR
S1
EXISTING RECEIVING
ELECTRICAL WORK IN THIS AREA
SEE: ELECTRICAL DRAWINGS
C
B
A
D
E
12 13 14 15
1 13
ELECTRICAL WORK
IN THIS AREA
SEE: ELECTRICAL
DRAWINGS
ELECTRICAL WORK IN
THIS AREA
SEE: ELECTRICAL
DRAWINGS
ELECTRICAL WORK IN THIS AREA
SEE: ELECTRICAL DRAWINGS
C
B
A
D
E
12 13 14 15
ELECTRICAL WORK IN THIS AREA
SEE: ELECTRICAL DRAWINGS
C
B
A
D
E
12 13 14 15
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON DESIGN INC.
905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204
317.800.6388 | WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
NON-SPRINKLERED
BLDG 102
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
AE
In st al l E M
S\ 2.
D ra w in gs \2
-1 _A rc hi te ct ur e\
1- 1_
R ev it\
.1
6.
M ilV
A R
TU
R ep la ce m en t B ui ld in g v1 6.
rv t
9/
/2
:5 6:
P
M
GI103
INFECTION CONTROL/PHASING
PLANRING & DuCHATEAU LLP
17400 W. CAPITOL DRIVE
BROOKFIELD, WI 53045
(414) 778-1700
INSTALL EMS BUILDING 102
MILWAUKEE VAMC
695-17-108
24 JULY 2017 ETA JP
100% CONSTRUCTION
DOCUMENTS
MILWAUKEE VA
SCALE: 1/8" = 1'-0"GI103
3 SECOND FLOOR INFECTION CONTROL PLAN
N
0' 4' 8' 16'
N
0' 4' 8' 16'
SCALE: 1/8" = 1'-0"GI103
2 FIRST FLOOR INFECTION CONTROL PLAN
SCALE: 1/8" = 1'-0"GI103
1 BASEMENT INFECTION CONTROL PLAN
N
0' 4' 8' 16'
GENERAL CONSTRUCTION NOTES
THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING THE
CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM AND THE
NATIONAL CAD STANDARD AS GUIDES.
DISCREPANCIES IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY BROUGHT
TO THE ATTENTION OF THE ARCHITECT AND OWNER’S REPRESENTATIVE/COR.
CONTRACTOR SHALL PROVIDE THE HIGHER GRADE OF QUALITY AND/OR GREATER
QUANTITY OF WORK WHEN BIDDING IF A CLARIFICATION CAN NOT BE OBTAINED BY
THE BID DUE DATE.
CONTRACTOR IS RESPONSIBLE FOR COORDINATING SCOPE OF WORK WITH COR AND
VARIOUS FACILITY PERSONNEL INVOLVED WITH UTILITY SHUT DOWN, INFECTION
CONTROLS, OCCUPANT/EMPLOYEE SAFETY, ACCESS CONTROL, ETC.
ANY INDICATION OF PROJECT LIMITS OR BOUNDARY OF DEMARCATION ARE SHOWN
FOR THE CONVENIENCE OF THE CONTRACTOR, THE FULL SCOPE OF THE PROJECT
LIMIT OF BOUNDARY REQUIRES COORDINATION WITH THE DESIGN SCOPE OF WORK
AND ACCESS TO EXISTING UTILITIES FOR TIE IN.
DRAWINGS ARE PREPARED FROM FIELD VERIFICATION, EXISTING FACILITY DRAWING
BASE FILES, AND USING DIMENSIONS, CONFIGURATIONS AND DETAILS OF SPECIFIC
MANUFACTURERS AS A BASIS OF DESIGN. CONTRACTOR IS RESPONSIBLE FOR
VERIFICATION OF ACTUAL DIMENSIONS, THE COORDINATION OF THE DETAILS WITH THE
PRODUCTS WHICH ARE PROVIDED PER THE SCOPE OF THE SPECIFICATIONS AND THE
SURROUNDING CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS, ROUGH-IN
DIMENSIONS, CONNECTIONS, AND OVERALL INSTALLATION REQUIREMENTS.
CONTRACTOR IS RESPONSIBLE FOR THE COMPLETION OF THE ENTIRE SCOPE OF
WORK OUTLINED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR
THE COORDINATION OF ALL SUB-CONTRACTORS AND THE SCOPE OF WORK THEY
PROVIDE. SUB-CONTRACTORS ARE RESPONSIBLE FOR THEIR FULL SCOPE OF WORK
WITHIN THE CONTRACT DOCUMENTS, TRADES ARE NOT SEGMENTED TO ONLY CERTAIN
SHEETS AND SPECIFICATIONS, CROSS COORDINATION IS REQUIRED.
CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR
UNDERSTANDING INFORMATION OUTLINED IN THE SPECIFICATIONS, KEY NOTES,
GENERAL NOTES, LEGEND, CODES, ETC., PROVIDED IN THE CONTRACT DOCUMENTS.
CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR PROVIDING AND
MAINTAINING SMOKE/FIRE RATINGS OF NEW CONSTRUCTION AND EXISTING
CONSTRUCTION AS INDICATED ON DRAWINGS. THIS INCLUDES PATCHING
PENETRATIONS IN SHAFTS, WALLS, SLABS AND ROOF. ONLY U.L. APPROVED METHODS,
MATERIALS AND INSTALLATION ARE ACCEPTABLE.
MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL DRAWINGS SHOW
INFORMATION IN A DIAGRAMMATIC FASHION WITHOUT DIMENSIONING. THE GENERAL
CONTRACTOR IS TO COORDINATE THE LOCATIONS OF ALL MECHANICAL, PLUMBING AND
ELECTRICAL EQUIPMENT WITH RESPECT TO THE ARCHITECTURAL AND STRUCTURAL
DETAILING OF SHAFTS, CHASES, CEILING CONSTRUCTION, ETC.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING DIMENSIONS IDENTIFIED AND NOT
IDENTIFIED IN THE CONTRACT DOCUMENTS WITH THE EXISTING AND NEW
CONSTRUCTION ELEMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION
BETWEEN THE CONTRACT DOCUMENTS, INSTALLED AND UNINSTALLED
CONSTRUCTION BEFORE THE ORDERING OF MATERIALS AND EQUIPMENT. NOTIFY
ARCHITECT AND OWNER’S REPRESENTATIVE/COR OF ANY DISCREPANCIES OR MISSING
DIMENSIONS.
DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR GENERAL
ORIENTATION AND CONTEXT ONLY.
ALL DIMENSIONS INDICATED ARE TO FACE OF EXISTING MEMBERS, FACE OF NEW
STRUCTURAL MEMBERS, FACE OF NEW MASONRY, FACE OF NEW STUDS OR COLUMN
GRID LINES UNLESS NOTED OTHERWISE.
ROUGH OPENINGS SHALL ALLOW FOR SHIM SPACE.
CONTRACTOR TO PROVIDE WORK WHERE DETAILS AND NOTES ARE IDENTIFIED AS
“TYPICAL” OR “SIMILAR” EACH INSTANCE THAT IS THE SAME IN NATURE TO THE DETAIL,
AREA, OR ITEM REFERENCED.
"PROVIDED" WORK SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR.
CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DELIVERY, MOUNTING,
INSTALLATION, NECESSARY BLOCKING AND ROUGH-IN.
"INSTALLED" WORK IS THE CONTRACTOR INSTALLING OWNER FURNISHED MATERIALS
AND EQUIPMENT. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF MATERIAL
DELIVERY, MOUNTING, INSTALLATION AND ROUGH IN.
"FURNISHED" WORK IS THE CONTRACTOR FURNISHING THE MATERIALS AND EQUIPMENT
TO THE OWNER. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DELIVERY AND
ROUGH-IN.
ALL PROVIDED WORK SHALL BE WITH NEW MATERIALS UNLESS SPECIFICALLY CALLED
OUT AS SALVAGED OR RELOCATED WITHIN THE CONTRACT DOCUMENTS.
ALL PERSONS DIRECTLY OR INDIRECTLY ASSOCIATED WITH THE PROJECT SHALL BE
FAMILIAR WITH THE RULES AND REGULATIONS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT, AND IMPLEMENT THOSE RULES AS THEY APPLY TO THIS PROJECT.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL
UTILITY LINES. LOCATIONS SHOWN ARE APPROXIMATE. REPAIR ALL DAMAGE TO UTILITY
LINES CAUSED BY CONSTRUCTION OPERATIONS AT NO COST TO THE OWNER.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING
REQUIRED DURING CONSTRUCTION.
CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ADJACENT CONSTRUCTION,
FINISHES, EQUIPMENT, AND TRAVEL ROUTE TO AND FROM THE CONSTRUCTION SITE.
ANY DAMAGE OR UNACCEPTABLE WEAR BY THE CONSTRUCTION TEAM SHALL BE
REPAIRED/REPLACED BY THE CONTRACTOR AT NO COST TO THE OWNER.
A/C AIR CONDITIONING
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
A&E ARCHITECT AND ENGINEERS
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITIES HAVING JURISDICTION
AHU AIR HANDLING UNIT
ALT ALTERNATIVE
ALT TRANS ALTERNATIVE TRANSPORTATION
ALUM ALUMINUM
ANOD ANODIZED
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AVG AVERAGE
BB BULLETIN BOARD
BD BOARD
BG BUMPER GUARD
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BO BOTTOM OF
BRG BEARING
CB CATCH BASIN
CBB CEMENTITIOUS BACKER BOARD
CER CERAMIC
CF CUBIC FEET
CFCI CONTRACTOR FURNISH CONTRACTOR INSTALL
CFM CUBIC FEET PER MINUTE
CG CORNER GUARD, CEILING GRILLE
C & G CURB & GUTTER
CI CAST IRON
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNITS
CO CLEANOUT(S)
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
CP CONCRETE PIPE
CPT CARPET
CRS COLD ROLLED STEEL
CS CAST STONE
CSB CONCRETE SPLASH BLOCK
CSI CONSTRUCTION SPECIFICATIONS INSTITUTE
CT CERAMIC TILE
CTR CENTER
CU FT CUBIC FEET
CUH CABINET UNIT HEATER
CY CUBIC YARD
D DRYER
DEG DEGREE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DISP DISPENSER
DIV DIVISION
DN DOWN
DR DOOR
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
E EAST
(E) EXISTING
EA EACH
EF EXHAUST FAN
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATED
ETS EXPOSED TO STRUCTURE
ETR EXISTING TO REMAIN
ARCHITECTURAL ABBREVIATIONS
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FF & E FURNITURE FIXTURES & EQUIPMENT
FIN FINISH
FIXT FIXTURE
FL FLOW LINE
FLR FLOOR
FLUOR FLUORESCENT
FO FINISH OPENING
FOS FACE OF STUD
FR FIRE RATED
FSP FIRE STANDPIPE
FT FOOT / FEET
FTG FOOTING
FURR FURRING
FV FIELD VERIFY
FVC FIRE VALVE CABINET
FWC FABRIC WALLCOVERING
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GARBAGE DISPOSAL
GF CMU GROUND FACE CMU
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GI GALVANIZED IRON
GL GLASS
GL BLK GLASS BLACK
GLU LAM GLUE LAMINATED WOOD
GND GROUND
GT GROUT
GYP BD GYPSUM BOARD
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIB
HC HOLLOW CORE
HCP HANDICAPPED
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR, HANDRAIL
HT HEIGHT
HVAC HEATING, VENTILATING & AIR CONDITIONING
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IG INSULATING GLASS
IN INCH
INCAN INCANDESCENT
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INV INVERT
ITG INSULATED TEMPERED GLASS
JAN JANITOR
J-BOX JUNCTION BOX
JT JOINT
L LONG
LAV LAVATORY
LB(S) # POUND(S)
LF LINEAL FEET
LLV LONG LEG VERTICAL
LT LIGHT
LVR LOUVER
M & BH MOP AND BROOM HOLDER
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MECH MECHANICAL
MEPF MECHANICAL, ELECTRICAL, PLUMBING,
FIRE PROTECTION (CONDUIT)
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MSB MOP SERVICE BASIN
MTD MOUNTED
MTL METAL
N NORTH
NA NOT APPLICABLE
NECY NECESSARY
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER,
OVERFLOW DRAIN
OFCI OWNER FURNISHED
CONTRACTOR INSTALLED
OFOI OWNER FURNISHED
OWNER INSTALLED
OH OPPOSITE HAND
OPN OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
P PLASTIC
PARTN PARTITION
PBD PARTICLE BOARD
PCC PRECAST CONCRETE
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATED
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
PT CONC POST-TENSIONED CONCRETE
PTD PAPER TOWEL DISPENSER
PTL PORCELAIN TILE
PVC POLYVINYL CHLORIDE
QA QUALITY ASSURANCE
QT QUARRY TILE
R R-VALUE (INSULATION),
RADIUS, RISER
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE: REFERENCE
REBAR REINFORCING BAR
REC RECESSED
RECPT RECEPTACLE
REF REFRIGERATOR
REG REGISTER
REINF REINFORCE
REQD REQUIRED
RESIL RESILIENT
REV REVISION
RH ROOF HATCH
RM ROOM
RO ROUGH OPENING
RT RUBBER STAIR TREAD
S SOUTH
SAF SEAMLESS ACRYLIC FLOORING
SAP SUSPENDED ACOUSTICAL PANELS
SAT SUSPENDED ACOUSTICAL TILE
SB SPLASHBLOCK
SC SEALED CONCRETE, SOLID CORE
SCHED SCHEDULE
SCP SCUPPER
SD SOAP DISPENSER
SEAL SEALER
SECT SECTION
SECT SECTION
SF SQUARE FOOT
SF CMU SPLIT-FACE CMU
SHR SHOWER
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SL SLOPE
SLV SHORT LEG VERTICAL
SND SANITARY NAPKIN DISPOSER
SNV SANITARY NAPKIN VENDOR
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUC STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
SYM SYMMETRICAL
SYS SYSTEM
T TREAD
TA TOILET ACCESSORIES
TB TACKBOARD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TBD TO BE DETERMINED
TD TUBULAR DAYLIGHTING DEVICE
TEL TELEPHONE
TEMP TEMPERATURE
TG TEMPERED GLASS,
TONGUE & GROOVE,
TRANSFER GRILLE
THRU THROUGH
TO TOP OF
TOC TOP OF CONCRETE
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TTD TOILET TISSUE DISPENSER
TV TELEVISION
TYP TYPICAL
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
URN URINAL
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDP WOOD PANELING
WDW WINDOW
WF WIDE FLANGE
WGL WIRED GLASS
WH WATER HEATER
WR WASTE RECEPTACLE,
WATER RESISTANT
WS WATER STOP
WSCT WAINSCOTT
WT WEIGHT
WWF WELDED WIRE FABRIC
ARCHITECTURAL SYMBOLS
X X
XXXX
SHEET LOCATION
VIEW NUMBER
X X
X
SHEET LOCATION
VIEW NUMBER
XXXX
BUILDING SECTION REFERENCE
SECTION REFERENCE
DRAWING NUMBER
SHEET LOCATION
DRAWING NUMBER
SHEET LOCATION
DRAWING NUMBER
SHEET LOCATION
DETAIL REFERENCE
BUILDING
OBJECT
REFERENCED
OBJECT
REFERENCED
X
XXXX
X
XXXX
ELEVATION REFERENCES
X
XXXX
X
XXXX
SCALE: ??
VIEW TITLE
HANDICAP SYMBOL
N
TRUE NORTH ARROW
ROOM
NEW WALL
WALL TO BE REMOVED
NEW WALL TAG
S3.A2
INDICATES STRUCTURAL MATERIAL
INDICATES NOMINAL STUD / BLOCK SIZE
INDICATES CONSTRUCTION
INDICATES TOP OF WALL CONDITION
REFER TO WALL LEGEND
FOR MORE INFORMATION
NEW DOOR101
DOOR TAG
EXISTING DOOR
101 ROOM TAG
1 PLAN NOTE
ROOF PLAN NOTE
A DEMO PLAN NOTE
ITEMS TO BE DEMOLISHED
DEMOLISHED DOOR
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
EXISTING WALL TO REMAIN
INCANDESCENT WALL MOUNTED LIGHTING
INCANDESCENT SURFACE MOUNT LIGHTING
SURFACE MOUNTED FLUORESCENT
RECESSED FLUORESCENT
HVAC RETURN AIR GRILLE
HVAC SUPPLY DIFFUSER
PENDANT LIGHT
ACCESS PANEL
EXIT LIGHTING
S
D
SPEAKER
SMOKE DETECTOR
INCANDESCENT RECESSED LIGHTING
A 9'-0"
CEILING TAG CEILING TYPE
FINISHED CEILING HEIGHT
REFER TO CEILING LEGEND
FOR MORE INFORMATION
EXTENT OF REVISION
REVISION SET
MECH/ELEC ITEMS: REFER TO MEP SHEETS AS APPLICABLE
101 EQUIPMENT/FURNITURE TAG
TEMPORARY IC BARRIER WALL
CONSTRUCTION (DUST WALL)
PROJECT BOUNDARY
BEYOND PROJECT BOUNDARY
REFLECTED CEILING PLAN SYMBOLS
DETAIL/DRAWING SCALE
TITLE OF DETAIL/DRAWING
DETAIL/DRAWING NUMBER
SHEET NUMBER
OTHER KEYNOTE TAG
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON DESIGN INC.
905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204
317.800.6388 | WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
NON-SPRINKLERED
BLDG 102
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
AE
In st al l E M
S\ 2.
D ra w in gs \2
-1 _A rc hi te ct ur e\
1- 1_
R ev it\
.1
6.
M ilV
A R
TU
R ep la ce m en t B ui ld in g v1 6.
rv t
9/
/2
:5 5:
P
M
AS001
ARCHITECTURAL SYMBOLS AND
ABBREVIATIONSRING & DuCHATEAU LLP
17400 W. CAPITOL DRIVE
BROOKFIELD, WI 53045
(414) 778-1700
INSTALL EMS BUILDING 102
MILWAUKEE VAMC
695-17-108
24 JULY 2017 ETA JP
100% CONSTRUCTION
DOCUMENTS
MILWAUKEE VA
D.S.
D.S.
DN
DN
M SDM
/1
SA
46/30 SA
/1
R
A
/36
SA
30/36 SA
EXISTING RECEIVING
ELEV
E1
EXISTING RECEIVING
STAIR
S1
F1
C
B
A
D
E
12 13 14 15
CONTRACTOR ROOF ACCESS
VIA SECOND FLOOR
CONTRACTOR HIGH ROOF
ACCESS VIA LOW ROOF
25' - 0" MINIMUM
27' - 4" VIF
0" V
IF
8"
V
IF
8' - 1" VIF
9" V
IF
50' - 4 1/2" VIF
4'
- 1
0" V
IF
7' - 4" VIF
4'
- 9
" V
IF
4' - 9" VIF
TYP.
4' - 0"
TY
P.
4'
- 0
PROPOSED NEW
ROOF TOP UNIT
LOCATION ABOVE
SLOPE
SLOPE
C
B
A
D
E
12 13 14 15
W
AL
KW
AY
4'
- 6
WALKWAY
4' - 6"
W
AL
KW
AY
4'
- 6
WALKWAY / VIF
5' - 2"
CONTRACTOR HIGH ROOF
ACCESS VIA LOW ROOF
AS501
FLOOR AND ROOF PLAN GENERAL NOTES
ROOF PLAN NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
A
B
C
REFERENCE STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR
COORDINATION ITEMS. COORDINATE AS REQUIRED INCLUDING NECESSARY
FRAMING, BLOCKING, ETC.
VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND
REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
THE CONTRACTOR IS RESPONSIBLE TO PROTECT THE EXISTING ROOF FROM
ANY RIPS OR TEARS AND MAINTAINING THE INTEGRITY OF THE ROOFING
SYSTEM.
PROVIDE ROOF CRICKET SLOPED MINIMUM 1/2" - 1' - 0" (1 : 24) ALONG THE EAST
SIDE OF THE NEW ROOF TOP UNIT. COORDINATE WITH MEP DRAWINGS.
PROVIDE ROOF CURB TO RECEIVE NEW ROOF TOP UNIT AS INDICATED ON
4/AS101 AND DETAIL 4 & 5/AS501. COORDINATE WITH MEP DRAWINGS FOR MORE
INFORMATION.
PROVIDE A 30" X 30" ACCESS DOOR AS INDICATED ON 3/AS101 AND DETAIL
5/AS501.
PROVIDE ROOF OPENING COVER AS INDICATED ON 3/AS101 AND DETAIL 1/AS501.
EXISTING VENT TO REMAIN. NOT IN SCOPE. REFER TO MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION.
PROVIDE PRECAST CONCRETE ROOF PAVERS.
PAINT ROOF WHITE TO EXTEND 4' - 0" OUTWARD FROM NEW ROOF TOP UNIT, AS
INDICATED ON PLAN 3/AS101.
PROVIDE ELEVATED ROOF WALKWAY SYSTEM AROUND NEW ROOF TOP UNIT.
ELEVATED HEIGHT OF ROOF WALKWAY SYSTEM TO ALIGN WITH HEIGHT OF
ROOF TOP UNIT AT TOP OF CURB TO ALLOW MAINTENANCE ACCESS TO UNIT.
PROVIDE ALL SUPPORTS AND CONNECTIONS FOR COMPLETE SYSTEM. PROVIDE
NEOPRENE RUBBER PADS UNDER EACH SUPPORT TO BEAR ON ROOF
ASSEMBLY. COORDINATE LOCATION AND SUPPORTS OF WALKWAY SYSTEM
WITH LOCATIONS AND SIZES OF DUCTWORK AND LOCATION AND SIZE OF ROOF
TOP UNITS. COORDINATE WIDTH OF WALKWAY SYSTEM WITH ACCESS DOORS OF
ROOF TOP UNIT TO ENSURE ACCESSIBILITY TO ROOF TOP UNIT AND
MAINTENANCE.
PROVIDE ROOF WALKWAY SYSTEM STAIRWAY TO CONNECT ROOF LEVEL UP TO
ROOF WALKWAY SYSTEM. COORDINATE NUMBER OF REQUIRED TREADS AND
RISERS BASED ON INSTALLED HEIGHT OF ROOF WALKWAY SYSTEM. STAIRS
DESIGNED AND ENGINEERED BY ROOF WALKWAY SYSTEM MANUFACTURER.
FLOOR PLAN NOTES
F1
PROVIDE A 12" X 12" TRANSFER GRILL IN EACH EXISTING DOOR. MODIFY EXISTING
DOOR AS REQUIRED TO ACCOMODATE TRANSFER GRILL.
25' - 0" MINIMUM
27' - 4" VIF 12
0"
V
IF
8" V
IF
8' - 1" VIF
9" V
IF
50' - 4 1/2" VIF
D1
D2
D3
PROPOSED NEW
ROOF TOP UNIT
LOCATION
C
B
A
D
E
12 13 14 15
DEMOLITION GENERAL NOTES
COORDINATE DEMOLITION WITH NEW CONSTRUCTION. ALL DEMOLITION AND
REPAIR NECESSARY TO COMPLETE NEW AND REMODEL CONSTRUCTION SHALL
BE PROVIDED. CONTRACTOR SHALL REMOVE EXISTING IMPROVEMENTS
WHETHER OR NOT SPECIFICALLY INDICATED ON THE DRAWINGS TO FACILITATE
THE COMPLETION OF ALL REQUIRED WORK. CONTRACTOR SHALL VISIT THE SITE
AND VERIFY ALL QUANTITIES AND ITEMS REQUIRED TO BE REMOVED.
REFER TO ARCHITECTURAL SYMBOLS ON SHEET AS001 FOR DEMOLITION
SYSTEMS AND DRAWING NOMENCLATURE.
EXISTING STRUCTURE WITHIN THE PROJECT BOUNDARY SHALL REMAIN UNLESS
NOTED OTHERWISE.
SURFACES TO BE CUT AND CONDITIONS UNDER WHICH CUTTING IS TO BE
PREFORMED SHALL BE REVIEWED BY CONTRACTOR PRIOR TO CUTTING TO
VERIFY NO UNSAFE OF UNSATISFACTORY CONDITIONS EXIST. SUCH CONDITIONS
SHALL BE RECTIFIED BEFORE WORK MAY PROCEED.
EXTENTS OF DEMOLITION SHALL BE COORDINATE WITH THE CONSTRUCTION
FLOOR PLAN AS101 AND ENGINEERING DRAWINGS FOR ADDITIONAL
INFORMATION.
DIMENSIONS SHOWN FOR EXISTING CONSTRUCTION TO BE DEMOLISHED ARE
APPROXIMATE AND ARE INTENDED TO GIVE A GENERAL SCOPE OF WORK TO BE
REMOVED OR TEMPORARILY REMOVED TO ACCOMMODATE NEW
CONSTRUCTION. COORDINATE DEMOLITION WORK WITH DESIGN INTENT OF NEW
CONSTRUCTION TO PROVIDE ADEQUATE AREA FOR THIS WORK.
CONTRACTORS SHALL REMOVE INDICATED DEMOLITION OF CONSTRUCTION
ASSEMBLIES IN THEIR ENTIRETY, UNLESS OTHER WISE NOTED, TO
ACCOMMODATE NEW CONSTRUCTION.
MAKE ALL DEMOLITION CLEAN AND COMPLETE IN A MANNER TO RECEIVE NEW
FINISHES. DEMOLITION SHOULD BE PERFORMED IN A MANNER SUCH THAT THE
CONTRACTOR CAN SEAMLESSLY PATCH NEW WORK TO BE SMOOTH AND
UNDETECABLE.
THE CONTRACTOR IS RESPONSIBLE TO PROTECT THE EXISTING ROOF FROM ANY
RIPS OR TEARS AND MAINTAINING THE INTEGRITY OF THE ROOFING SYSTEM.
A.
B.
C.
D.
E.
F.
G.
H.
I.
DEMOLITION PLAN NOTES
D1.
D2.
D3.
CUT AND PREPARE ROOF FOR NEW ROOF CURB AS INDICATED ON PLAN.
COORDINATE WITH MEP DRAWINGS AND WITH MANUFACTURER SIZE OF
EQUIPMENT AND REQUIREMENTS.
COORDINATE WITH MEP DRAWINGS FOR EXISTING ROOF TOP UNIT REMOVAL.
COORDINATE WITH MEP DRAWINGS FOR EXISTING DAMPER REMOVAL.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON DESIGN INC.
905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204
317.800.6388 | WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
NON-SPRINKLERED
BLDG 102
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
AE
In st al l E M
S\ 2.
D ra w in gs \2
-1 _A rc hi te ct ur e\
1- 1_
R ev it\
.1
6.
M ilV
A R
TU
R ep la ce m en t B ui ld in g v1 6.
rv t
9/
/2
:5 5:
P
M
AS101
FLOOR PLANS
RING & DuCHATEAU LLP
17400 W. CAPITOL DRIVE
BROOKFIELD, WI 53045
(414) 778-1700
INSTALL EMS BUILDING 102
MILWAUKEE VAMC
695-17-108
24 JULY 2017 ETA JP
100% CONSTRUCTION
DOCUMENTS
MILWAUKEE VA
SCALE: 1/8" = 1'-0"AS101
2 SECOND FLOOR PLAN
SCALE: 1/8" = 1'-0"AS101
3 HIGH ROOF PLAN
SCALE: 1/8" = 1'-0"AS101
1 HIGH ROOF DEMO PLAN
N
0' 4' 8' 16'
N
0' 4' 8' 16'
N
IT
ROOM
CHILLER
MECHANICAL
CORRIDOR
ELECTRIC
MECH.
SPRINKLER
SERV. ROOM
B100FC
B100
B110
B115
B120
B125
B100FP
STAIR UP
ST
AI
R
DO
W N
STAIR DOWN
STAIR UP
ANTE
PPE
KER
KER
CLEAN RECEIVING
& BREAK OUT
DISPATCH
BULK
STORAGE
ANTE
CLEAN CART
HOLDING
UNASSIGNED
HAC
EMS
PACKING
SHIPPING
151HC
C
B
A
D
E
12 13 14 15
PAINTED CONCRETE
CEILING
EXISTING TO
REMAIN
PAINTED CONCRETE
CEILING
EXISTING TO
REMAIN
C
B
A
D
E
12 13 14 15
PAINTED CONCRETE
CEILING
EXISTING TO
REMAIN
ACOUSTICAL CEILING TILE
EXISTING TO REMAIN
PAINTED CONCRETE
CEILING
EXISTING TO
REMAIN
ACOUSTICAL CEILING TILE
EXISTING TO REMAIN
4' - 10" 1' - 4"
1' - 2 1/2" 1' - 9"
4'
- 3
2'
- 0
PROPOSED NEW
ROOF TOP UNIT
LOCATION ABOVE
4' - 1" 4' - 1"
6'
- 8
6'
- 8
8' - 2"
AS501
AS501
4"
AS501
AS501
Sim
AS501
Sim
AS501
Sim
W 8X
W
8X
W 8X
W
8X
C
B
A
D
E
12 13 14 15
PLASTER CEILING
EXISTING TO REMAIN
EXISTING RECEIVING
STAIR
S1ELEV
E1
EXISTING RECEIVING
EXPOSED CEILING
EXISTING TO REMAIN
AS501
REFLECTED CEILING GENERAL NOTES
REFLECTED CEILING PLAN NOTES
1.
2.
3.
4.
5.
A
B
REFERENCE STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR
COORDINATION ITEMS. COORDINATE AS REQUIRED INCLUDING NECESSARY
FRAMING, BLOCKING, ETC.
VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND
REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
PROVIDE ROOF DUCT PENETRATION COVER. REFER TO DETAIL 2 & 4/AS501 AND
MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
PROVIDE NEW STRUCTURAL MEMBERS TO BE BOLTED TO THE EXISTING
STRUCTURE. REFER TO DETAIL 3/AS501.
EXISTING CEILING TO REMAIN. PATCH, REPAIR AND REFINISH CEILING WHERE
WORK OCCURS TO RETURN TO LIKE NEW CONDITION. PAINT CEILING IN AREA TO
MATCH EXISTING PAINT COLOR. PAINT ENTIRE CEILING FOR SEEMLESS COLOR IF
COLOR MATCH IS NOT AVAILABLE.
EXISTING CEILING TO REMAIN. REMOVE AND PROTECT CEILING TILES DURING
CONSTRUCTION AS REQUIRED TO PERFORM WORK. REINSTALL CEILINGS AND
RETURN TO LIKE NEW CONDITION UPON COMPLETION OF WORK IN THIS AREA.
PAINT ALL NEW WORK IN THIS AREA TO MATCH EXISTING EXPOSED CEILING.
PROTECT ALL EXISTING STRUCTURE AND EQUIPMENT DURING WORK.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON DESIGN INC.
905 N. CAPITOL AVE. SUITE 100 | INDIANAPOLIS, IN. 46204
317.800.6388 | WWW.GUIDONDESIGN.COM
SUSTAINABLE ARCHITECTURE + ENGINEERING
PROJECT LEAD
Architect, Structural Engineer, Civil Engineer
NON-SPRINKLERED
BLDG 102
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
AE
In st al l E M
S\ 2.
D ra w in gs \2
-1 _A rc hi te ct ur e\
1- 1_
R ev it\
.1
6.
M ilV
A R
TU
R ep la ce m en t B ui ld in g v1 6.
rv t
9/
/2
:5 5:
P
M
AS102
REFLECTED CEILING PLANS
RING & DuCHATEAU LLP
17400 W. CAPITOL DRIVE
BROOKFIELD, WI 53045
(414) 778-1700
INSTALL EMS BUILDING 102
MILWAUKEE VAMC
695-17-108
24 JULY 2017
100% CONSTRUCTION
DOCUMENTS
MILWAUKEE VA
N
0' 4' 8' 16'
SCALE: 1/8" = 1'-0"AS102
1 BASEMENT REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"AS102
2 FIRST FLOOR REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"AS102
3 SECOND FLOOR REFLECTED CEILING PLAN
N
0' 4' 8' 16'
N
EXISTING ROOF DECK
EXISTING STRUCTURAL BEAM
WIDE FLANGE W8X10
L-ANGLE BOLTED CONNECTION PER
STANDARD AISC CONNECTION
B
GASKET BY RTU PROVIDER
SHEET METAL CAP FLASHING
(REFER TO SPECS FOR THICKNESS)
COORDIANTE FLASHING WITH ROOF
TOP UNIT MANUFACTURER
EXISTING PROTECTION BOARD
EXISTING TAPERED RIGID INSULATION
WOOD BLOCKING
EXISTING METAL DECK
6", 16 GA. METAL STUD FRAMING TO DECK
STRUCTURE BELOW AT 12" O.C. MIN.RE
: M
EC
HA
NI
C A L
DU
CT
W
ID
TH
MI
N.
1'
- 0
DUCT PENETRATION,
RE: MECHANICAL
CONTINUOUS SEALANT
PREFORMED DUCT FLASHING
AROUND DUCT OPENING BY DUCT
MANUFACTURER
WIDE FLANGE W8X10
RE: 3/AS101 & 5/AS101
EXISTING EPDM ROOFING MEMBRANE
NOTE:
AS-BUILT CONDITION IN FIELD TO BE VERIFIED
BY CONTRACTOR. ANY DISCREPANCIES
SHALL BE ISSUED TO COR AND ARCHITECT.
CONTINUOUS SEALANT
EPDM ROOFING MEMBRANE
(REFER TO SPECS FOR THICKNESS)
3/4" PROTECTION BOARD
CANT STRIP
NEW ROOF TOP UNIT,
RE: MECHANICAL
MI
N.
1'
- 0
VE
RI
FY
W
IT
H
AH
U/
RT
U
MA
NU
FA
CT
UR
ER
A
ND
M
EC
H
DW
GS
DESIGN INTENT NOTE:
THIS DETAIL REPRESENTS AN EXTENDED HEIGHT ROOF TOP UNIT CURB PROVIDED BY THE CONTRACTOR THAT CONNECTS TO THE EXISTING ROOF STRUCTURE. THE NEW ROOF TOP UNIT IS TO BE CONNECTED TO THE NEW CURB PER MANUFACTURER RECOMMENDATION TO ENSURE PROPER FUNCTIONALITY AND WARRANTY.
CONTRACTOR IS PERMITTED TO PROVIDE THE ENTIRE CURB BY ROOF TOP UNIT MANUFACTURER IF AVAILABLE.
CONTRACTOR TO SUBMIT FOR APPROVAL SHOP DRAWINGS, PRODUCT DATA AND ENGINEER CALCULATIONS FOR
ROOF TOP UNIT CURB WHETHER PROVIDED BY CONTRACTOR OR ROOF TOP UNIT MANUFACTURER.
GASKET BY RTU PROVIDER
SHEET METAL CAP FLASHING
(REFER TO SPECS FOR THICKNESS)
COORDIANTE FLASHING WITH ROOF
TOP UNIT MANUFACTURER
EXISTING PROTECTION BOARD
EXISTING TAPERED RIGID INSULATION
WOOD BLOCKING
EXISTING METAL DECK
6", 16 GA. METAL STUD FRAMING TO DECK
STRUCTURE BELOW AT 12" O.C. MIN.
30" X 30" ACCESS DOOR
CONTINUOUS SEALANT
WIDE FLANGE W8X10
RE: 3/AS101 & 5/AS101
NOTE:
AS-BUILT CONDITION IN FIELD TO BE VERIFIED
BY CONTRACTOR. ANY DISCREPANCIES
SHALL BE ISSUED TO COR AND ARCHITECT.
CONTINUOUS SEALANT
EPDM ROOFING MEMBRANE
(REFER TO SPECS FOR THICKNESS)
3/4" PROTECTION BOARD
CANT STRIP
DO
OR
W
ID
TH
MI
N.
1'
- 0
EXISTING EPDM ROOFING MEMBRANE
NEW ROOF TOP UNIT,
RE: MECHANICAL
VE
RI
FY
W
IT
H
AH
U/
RT
U
MA
NU
FA
CT
UR
ER
A
ND
M
EC
H
DW
GS
DESIGN INTENT NOTE:
THIS DETAIL REPRESENTS AN EXTENDED HEIGHT ROOF TOP UNIT CURB PROVIDED BY THE CONTRACTOR THAT CONNECTS TO THE EXISTING ROOF STRUCTURE. THE NEW ROOF TOP UNIT IS TO BE CONNECTED TO THE NEW CURB PER MANUFACTURER RECOMMENDATION TO ENSURE PROPER FUNCTIONALITY AND WARRANTY.
CONTRACTOR IS PERMITTED TO PROVIDE THE ENTIRE CURB BY ROOF TOP UNIT MANUFACTURER IF AVAILABLE.
CONTRACTOR TO SUBMIT FOR APPROVAL SHOP DRAWINGS, PRODUCT DATA AND ENGINEER CALCULATIONS FOR
ROOF TOP UNIT CURB WHETHER PROVIDED BY CONTRACTOR OR ROOF TOP UNIT MANUFACTURER.
EPDM ROOFING MEMBRANE
(REFER TO SPECS FOR THICKNESS)
3-5/8" METAL STUD FRAMING
CANT STRIP
EXISTING ROOF
EXISITING ROOF CURB
EXISITING DUCTS,
RE: MECHANICAL
MI
N.
1'
- 0
RE
: M
EC
HA
NI
CA
L
DU
CT
W
ID
TH
7 3
/4"
EXISTING EPDM ROOFING MEMBRANE
SPRAY FOAM INSULATION MIN R-20
STAINLESS STEEL SHEET METAL, 20 GA.
3/4" PROTECTION BOARD
1-1/2", 18 GA., METAL ROOF DECKING,
SLOPE = 1/4" : 12"
DUCTS,
RE: MECHANICAL
EXISTING ROOF OPENING
EPDM ROOFING MEMBRANE
(REFER TO SPECS FOR THICKNESS)
AS501
AS501
SLOPE: MIN 1/4" : 12"
EPDM ROOFING MEMBRANE
(REFER TO SPECS FOR THICKNESS)
3-5/8" METAL STUD FRAMING
CANT STRIP
EXISTING ROOF
EXISITING ROOF CURB
EXISTING EPDM ROOFING MEMBRANE
STAINLESS STEEL SHEET METAL, 20 GA.
EPDM ROOFING MEMBRANE
(MIN 60 MILS)
1-1/2", 20 GA., METAL ROOF DECKING,
SLOPE = 1/4" : 12"
SPRAY FOAM INSULATION MIN R-20
3/4" PROTECTION BOARD
EXISTING ROOF OPENING
AS501
Sim
AS501
Sim
SLOPE: MIN 1/4" : 12"
3-5/8" METAL STUD FRAMING
3/4" PROTECTION BOARD
1-1/2", 20 GA., METAL ROOF DECKING,
SLOPE = 1/4" : 12"
EPDM ROOFING MEMBRANE
(REFER TO SPECS FOR THICKNESS),
OVERLAPPED PER MANUFACTURER 'S
SPECIFICATION
3/4" PROTECTION BOARD
EPDM ROOFING MEMBRANE
(REFER TO SPECS FOR THICKNESS)
EPDM ROOFING MEMBRANE
(REFER TO SPECS FOR THICKNESS),
OVERLAPPED PER MANUFACTURER'S
SPECIFICATION
CANT STRIP
EXISTING ROOF
EXISITING ROOF
CURB
EXISTING EPDM ROOFING MEMBRANE
3-5/8" METAL STUD FRAMING
3/4" PROTECTION BOARD
NOTE:
AS-BUILT CONDITION IN FIELD TO BE VERIFIED
BY CONTRACTOR. ANY DISCREPANCIES
SHALL BE ISSUED…