This document is an addendum to the solicitation for VA Project No. 655-20-202, Atrium Renovation Building 22 at the Aleda E. Lutz VA Medical Center in Saginaw, Michigan. The addendum revises the structural and architectural drawings, including updates to concrete pier details and footing notes. The overall project involves furnishing labor, tools, materials, and equipment to complete the atrium renovation, which includes exterior canopy construction, selective interior demolition, new interior construction, flooring replacement, and pavement repair. The solicitation number is 36C25024B0058 and the procuring agency is the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 10.
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA Project No. 655-20-202 Alliance | Seven Generations A+E Joint Venture Page 1 of 1
ADDENDUM NO. 2
Project VA Saginaw Atrium Renovation Building 22
VA Project No. 655-20-202
AE Project No. 220030/1704.19
Date October 16, 2024
Notice This Addendum is issued by the Architect to all known individuals, firms, or corporations who have obtained or received bidding documents and contract documents for the above-listed project. This Addendum hereby makes a portion of bidding documents or contract documents, as appropriate. It is issued for the purpose of amplifying, clarifying, or correcting originally issued bid documents. Bidders are required to acknowledge receipt of this Addendum in the appropriate space on the bid form.
AD2-1 STRUCTURAL
A. DRAWING ITEMS
1. DRAWING S001 (Reissued):
a. Revise Keynote 6 to read: “1’-6” CONCRETE PIER”
b. Revise slab edge note on Detail 01/S001 to read: “#4 x 1’-0” LONG STAINLESS STEEL
THREADED ROD W/4” MIN EMBED INTO EXISTING @ 12” ON CENTER.”
AD2-2 ARCHITECTURAL
A. DRAWING ITEMS
1. Drawing AE301 (Reissued):
a. Revise footing note on Metal Canopy Plan to read: “1’-6” DIA CONC. PIER TYP. @ OUTSIDE
POSTS; REFER TO STRUCT.”
b. Revise footing note on Section 02/AE301 to read: “1’-6” DIA CONC. PIER; REFER TO
STRUCT.”
c. Revise footing note on Section 04/AE301 to read: “1’-6” DIA CONC. PIER; REFER TO
STRUCT.”
End of Addendum No. 2
NTF/crg \\leopold\Projects\2020 Projects\220030 VA Saginaw Atrium Renovation\02_Documents\03_Construction Administration\Addendums\2024 10 16 Addendum No. 2\ADDENDUM NO 2.docx d d
4d OR
2~8" MIN
d
O R
M
IN
6d O
R 4" M
IN
12d d d d d d d
O R
M
IN
d
O R
M
IN
6d O
R
4" M
IN
6d OR
4" MIN
ALL REINFORCING EXCEPT COLUMN TIES AND BEAM STIRRUPS
BEAM STIRRUPS AND COLUMN TIES
BEAM OR COLUMN CROSSTIES
45°
45° d = BAR DIAMETER, D = BEND DIAMETER
90° D D
135°
DD
STIRRUP
D
D 180°
D
D
90°
90° D
180° D
STIRRUP OR TIE
135°
D
90°
D
D
D 180°
D = 6d FOR #3 THRU #8 D = 8d FOR #9, 10 & 11
D = 4d FOR #3, 4 & 5 D = 6d FOR #6, 7 & 8
OTHER BARS
MIN DEVELOPMENT
LENGTH "Ld"
MIN LAP SPLICE
LENGTH "Ls"
TOP BARS
MIN DEVELOPMENT
LENGTH "Ld"
MIN LAP SPLICE
LENGTH "Ls"
BAR
SIZE
MIN EMBEDMENT
LENGTH FOR
STANDARD END
HOOK "Ldh"
#3
#4
#5
#6
#7
#8
#9
#10
#11
CONCRETE COMPRESSIVE STRENGTH @ 28 DAYS = 3000 psi
NOTES:
1. VALUES ARE IN INCHES FOR UNCOATED REINFORCING AND NORMAL WEIGHT CONCRETE WITH
CLEAR SPACING > db, CLEAR COVER > db AND MINIMUM STIRRUPS OR TIES THROUGHOUT Ld
OR CLEAR SPACING > 2db AND CLEAR COVER > db.
2. DEVELOP ALL REINFORCING IN STRUCTURAL SLABS WITH MINIMUM DEVELOPMENT LENGTH Ld.
3. TOP BAR = HORIZONTAL BAR WITH MORE THAN 12" OF FRESH CONCRETE BELOW OR AS NOTED
ON DOCUMENTS AS "TOP BAR".
4. LAP SPLICES SHOWN ARE CLASS B.
5. THIS TABLE IS NOT FOR COLUMNS OR SHEAR WALLS. SEE SPECIFIC SCHEDULES.
(1,2,4,5)
(3)
SAW CUT JOINT
NOTES:
1. USE "EARLY ENTRY DRY-CUT SAW" AS SOON AS POSSIBLE WITHOUT
CAUSING RAVELING OF CONCRETE EDGES. SAWCUT ALONG SHORT
DIRECTION OF POUR FIRST.
1/8" WIDE X t/4 SAW CUT DEPTH
OR 1-1/2" PRE-MOLDED JOINT.
FILL CUT JOINT w/ MASTIC
RUN EVERY OTHER REINF.
CONTINUOUS THRU JOINT AND
STOP REMAINING REINF. 4" CLR.
FROM JOINT.
SNOW LOADS (PER ASCE 7-10):
• GROUND SNOW LOAD (pg): 35 lb/ft2
• EXPOSURE FACTOR (Ce): 1.0
• THERMAL FACTOR (Ct); 1.0
SEISMIC LOADS (PER ASCE 7-10):
• SITE CLASS D
• MCER GROUND MOTION (PERIOR=0.2s) (Ss): 0.069
• MCER GROUND MOTION (PERIOR=1.0s) (S1): 0.04
• NUMERI SEISMIC DESIGN VALUE AT 0.2s (SDS): 0.074
• NUMERIC SEISMIC DISIGN VALUE AT 1.0s (SD1): 0.064
WIND LOADS (PER ASCE 7-10):
• EXPOSURE CATEGORY: C
• ULTIMATE WIND SPEED: 120 lb/ft2
FROST DEPTH:
• FROST DEPTH: 42 inches
DESIGN LOAD REQUIREMENTS
U
TQK K.1 NL.5
U.8
0.1
K.2
S001
Sim
4X4 CANOPY
COLUMN BY CANOPY
MANUFACTURER, TYP.
8" 6' - 10" 6' - 11 3/4" 8' - 3 1/2" 8' - 3 1/2" 8' - 3 1/2" 8' - 3 1/2" 8' - 3 3/4" 5' - 9" 5' - 9"
1' - 4 5/16"
" 5
/2
/4
/2
/2
01 02
TYP.
EXISTING CONC.
FOUNDATION
WALL
1'-6"
1'-2"
2"CLR
TYP
8" 1 1/2"
TYP
3/16
PIER SECTION
FIELD WELD COL
TO EMBED PLATE
FIELD WELD COL
TO EMBED PLATE
PLATE TO REINF
#3 SPIRAL @3° PITCH
(4) #6 VERTICAL
CONCRETE PIER
6" CONC SLAB ON GRADE
W/#3 REBAR @18"OC EACH
WAY OVER 6" OF
COMPACTED CRUSHED
ROCK PER PLAN
HSS4x4x1/4
STEEL COLUMN
CL COL
CL PIER
CL COL
EMBED PLATE 1/2 x 8" x 8"
W/(4) 3/4 " x 6" WHS
EMBED PLATE
EMBED PLATE 1/2 x 8" x 8"
W/(4) 3/4 " x 6" WHS
HSS4x4x1/4
STEEL COLUMN
(2)#5
(A706)
WELDABLE REINF
8"
EMBED PLATE
1/2 x 1'-0" x 1'-0"
1/4
EMBED PLATE
1/4
1/4
#4 x 1'-0" LONG STAINLESS STEEL
THREADED ROD W/4" MIN EMBED
INTO EXISTING @ 12" ON CENTER.
1/2 PRE-MOLDED JOINT FILLER
NOTES:
1. CONTRACTOR TO COORDINATE DETAIL WITH CANOPY
MANUFACTURER PRIOR TO CONSTRUCTION.
2. SUBMIT CANOPY BASE REACTION FOR REVIEW PRIOR
TO FABRICATION AND CONSTRUCTION.
3. CANOPY MANUFACTURER TO SUBMIT SIGNED AND
SEALED DRAWINGS FOR CANOPY AND FOUNDATIONS.
1' - 0"
M
IN
1' - 0"
TY
P
TY
P
C
LR
1' - 6"
1' - 0"
AD2
FOUNDATION & ROOF
FRAMING KEYNOTES
01 INDICATED OUTLINE OF EXISTING STRUCTURE.
02 EXISTING WALL.
03 HSS 6X4X1/4 BEAM BELOW.
04 HSS 4X4X1/4 COLUMN BASE PLATE BY METAL
CANOPY MANUF.
05 6" CONCRETE SLAB ON GRADE w/ #3 @18" o.c. REBAR
EACH WAY OVER 6" COMPACTED CRUSHED ROCK.
06 1'-6" CONCRETE PIER
07 12" X 6" CONCRETE SLAB EDGE. DRILL & EPOXY
DOWEL WALL AND FOOTING HORIZONTAL
REINFORCING 4" MINIMUM INTO EXISTING, TYP.
WHERE NEW MEETS EXISTING.
AD2
U
TQK K.1 NL.5
U.8
0.1
K.2
C.J.
4' - 1 3/4" 4' - 1 3/4"4' - 1 3/4" 4' - 1 3/4" 4' - 1 3/4" 4' - 1 3/4"3' - 5 7/8" 3' - 5 7/8" 4' - 1 3/4" 4' - 1 3/4"3' - 5" 3' - 5" 4' - 1 7/8" 4' - 1 7/8" 5' - 9" 5' - 9"
C.J.C.J.C.J.C.J. C.J. C.J. C.J.
C.J.
C.J.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DWG. ___ OF 32
7GAE PROJECT NO.: 219123
Sprinkler:
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
FOUNDATION & FRAMING
DETAILS
ATRIUM RENOVATION
BUILDING 22
ALEDA E. LUTZ VA MEDICAL CENTER
655-20-202
11.11.2021 GM NTF
100% BID
DOCUMENTS
S001
FULLY SPRINKLED
SCALE: NTSS001
STANDARD HOOKS, BENDS, STIRRUPS, AND TIES02
SCALE: NTSS001
CONTROL JOINT DETAIL03
NORTH
SCALE: 1/4" = 1'-0"
METAL CANOPY FOUNDATION
PLAN
SCALE: 1" = 1'-0"S001
FOOTING DETAIL AT METAL CANOPY01
NORTH
SCALE: 1/4" = 1'-0"
METAL CANOPY CONTROL
JOINT PLAN
Revisions: Date:
100% BID DOCUMENTS 11-11-2021
AD2 - ADDENDUM NO. 2 10-16-2024
ELEV. 607' - 9 1/2"
B22 - FIRST FLOOR - ATRIUM
AE301
AE301
6' - 10 1/8" 6' - 11 5/8" 8' - 3 1/2" 8' - 3 1/2" 8' - 3 1/2" 8' - 3 1/2" 8' - 3 3/4" 11' - 6"
/2
/4
/2
LINE OF CANOPY
ROOF PERIMETER
ABOVE
1'-6" DIA CONC. PIER
TYP. @ OUTSIDE POSTS;
REFER TO STRUCT.
4"X4"X.125
EXTRUDED ALUM.
POST TYP.; BY PRE-
ENGINEERED MTL
CANOPY MANUF.
/2
/2
/2
/2
5' - 9" 5' - 9"
66' - 9 1/2"
AD2
4" X 4" X .125 EXTRUDED ALUM. POST
W/ 4" FACTORY NOTCH @ TOP
EXTR. ALUM. STRUCTURAL BEAM END
CLOSURE (SEAL ALL AROUND, BY
CANOPY INSTALLER)
1'-6" DIA CONC. PIER; REFER TO
STRUCT.
2' - 0"
VARIES 3 1/2"
TY
P
6" CONC. SLAB; REFER TO STRUCT.
LINE OF EXISTING ATRIUM STRUCTURE
TO REMAIN
AE301
Sim
12" X 6" THICKENED CONC. SLAB
EDGE W/ 1/2" PRE-MOLDED
EXPANSION JOINT FILLER; REFER TO
STRUCT.
1 1/2" MIN.
AD2
AE301
AE301
AE301
/4
1' - 0"
1' - 1 1/2"
/4
/4
/4
EXTRUDED ALUM. BEAMS NOTCHED
INTO FASCIA PROFILE
NOTE:
THE CONTRACTOR SHALL VERIFY
THE POST HEIGHT IN THE FIELD TO
ENSURE A LEVEL ROOF
TY
P
PERFORATED ALUM.
WINDSCREEN
/4
/4
/4
/4
/4
AE301
AE301
AE301
Sim
5" ALUM. INTERLOCKING DECKING
8" EXTRUDED ALUMINUM FASCIA
CANOPY DRAINS FROM DECK,
INTERNALLY THROUGH SUPPORT
BEAMS, AND DOWN THROUGH POSTS
TO OUTLET AT BASE.
DRAIN ONLY AT OUTER POST
LOCATIONS TOWARD CURB
FASCIA
SUPPORT BRACKET
5" WIDE X .078 EXTRUDED ALUM.
INTERLOCKING DECKING
EXTR. ALUM. STRUCTURAL
BEAM END CLOSURE
(SEAL ALL AROUND,
BY CANOPY INSTALLER)
3.68" X 7" X .156
EXTRUDED ALUM. BEAM
(CLOSED & SEALED AT ENDS)
4" X 4" X .125 EXTRUDED
ALUM. POST W/ 4"
FACTORY NOTCH @ TOP
NOTCH BEAM AT
FASCIA4
/8
/8
/8
8" EXTRUDED
ALUMINUM FASCIA
3 1/2" WIDTH VARIES 2' - 0"
EXTRUDED ALUM. BEAM (CLOSED &
SEALED AT ENDS)
EXTRUDED ALUM. STRUCTURAL BEAM
END CLOSURE (SEAL ALL AROUND,
BY CANOPY INSTALLER)
8" EXTRUDED ALUM. FASCIA
5" WIDE X .078 EXTRUDED
ALUM. INTERLOCKING
DECKING
2"
/8
1' - 0"
3" ID PIPE STEEL SURFACE-
MOUNTED POST BRACKET
STEEL CAP
3" ID PIPE STEEL
SURFACE-MOUNTED
POST BRACKET
STEEL CAP
8X8X.375 BASE OF POST BRACKET
(WELDED TO 3" ID PIPE ABOVE,
BY MANUFACTERED)
ø 3 7/16"
/4
/8
8"
7"
1" ø
/1
5/8"x6 BOLT ANCHOR (4 TYP.)
4"X4"X.125 EXTRUDED ALUM. POST
3" ID PIPE STEEL SURFACE-MOUNTED
POST BRACKET
ALUM. POP RIVET, 5 @ 6" O.C. @ SIDE OF
COLUMN
8 X 8 X .375 STEEL BASE BASE PLATE OF POST
BRACKET (WELDED TO 3" ID PIPE ABOVE, BY
MANUFACTURER)
2" DIA. DRAIN HOLE (FIELD DRILL) IN 4X4
COLUMN ONLY (POST BRACKET IS SEALED)
SILICONE SEALANT ON 3 SIDES OF POST;
PUSH SEPARATOR MATERIAL UP TO
CLEAR DRAIN HOLE IN 4X4 COLUMN
.0625 HD POLYETHYLENE
SPACER AS SEPARATOR
MATERIAL BETWEEN
DISSIMILAR METALS
STEEL CAP
(T U
B E
EQ EQ
6"
1'-6" DIA CONC. PIER; REFER TO STRUCT.
1/2" NEOPRENE SPACER
AD2
DRAIN HOLE POSITIONED ON FACE LOOKING
TOWARD STREET CURB
DRAIN HOLE
DRAIN HOLE
EXTRUDED ALUM. FASCIA
NOTCH BEAM
AT FASCIA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
DWG. ___ OF 32
7GAE PROJECT NO.: 219123
Sprinkler:
600 E. Michigan Avenue, Suite B
Kalamazoo, MI 49007
P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310
Alexandria, VA 22314
P: 202.617.8485 www.alliance.us.com
METAL CANOPY PLAN &
DETAILS
ATRIUM RENOVATION
BUILDING 22
ALEDA E. LUTZ VA MEDICAL CENTER
655-20-202
11.11.2021 JD NTF
100% BID
DOCUMENTS
AE301
FULLY SPRINKLED
SCALE:
METAL CANOPY 3D ORTHOGRAPHIC VIEW
NORTH
SCALE: 1/4" = 1'-0"
METAL CANOPY PLAN
SCALE: 3/4" = 1'-0"AE301
METAL CANOPY SECTION02
SCALE: 1/4" = 1'-0"AE301
METAL CANOPY FRONT ELEVATION01
NORTH
SCALE: 1/4" = 1'-0"
METAL CANOPY ROOF PLAN
SCALE: 1 1/2" = 1'-0"AE301
CANOPY CROSS SECTION DETAIL05
SCALE: 1 1/2" = 1'-0"AE301
CANOPY FASCIA SECTION @ END06
SCALE: 1 1/2" = 1'-0"AE301
CANOPY 4X4 POST SURFACE BACKET DETAIL03
SCALE: 1 1/2" = 1'-0"AE301
CANOPY 4X4 POST SURFACE BRACKET SECTION04
SCALE: 3/4" = 1'-0"AE301
CANOPY POST DRAIN LOCATIONS07
Revisions: Date:
100% BID DOCUMENTS 11-11-2021
AD2 - ADDENDUM NO. 2 10-16-2024
NOTE: CANAPY DETAILS ARE SCHEMATIC
ONLY. FINAL DETAILS AND ASSEMBLY PLANS
TO BE PROVIDED BY BASIS OF DESIGN METAL
CANOPY MANUFACTURER IN SIGNED AND
SEALD SHOP DRAWINGS.