Drawings 11-04-2020.pdf
PDF 13 MB Posted
- Solicitation number
- 36C25021B0038
About this file
This document provides details for a federal contract solicitation issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10. The solicitation, numbered 36C25021B0038, is for a construction project to reconfigure the second floor waiting and check-in areas at the VA Medical Center located in Cincinnati, Ohio. Work includes general construction, alterations, plumbing, mechanical and electrical work to construct a new radiology check-in area, renovate portions of the existing radiology waiting area, construct a new office and reading room, renovate an unfinished room into a shared breakroom, and renovate various rooms. The existing nuclear medicine area will also be renovated to share a check-in space with cardiology. Drawings and specifications for the project are available through the System for Award Management website. Bids for the solicitation must be submitted through the same website.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXTERIOR ELEVATION
INTERIOR ELEVATION
SEE A400 SERIES SHEETS
SECTION/DETAIL NUMBER
DRAWING NUMBER
EQUIPMENT TAG
COLUMN GRID
NOTE
WINDOW OPENING
DOOR OPENING
ROOM NAME
ROOM NUMBER
WALL TYPE
SEE SHEET A001
CEILING HEIGHT
FINISH DESIGNATION
X
10'-8"
X
X
XX.X-X
XX
X
1/A101
X
A101
XX
TOILET ACCESSORY TAGX
X
XXX
Ludlow Ave.
C lif to n A v e
CINCINNATI
STATE
TECH.
Hopple St.
M.L.K. Dr.
McMillan St.
UNIV. OF
CINCINNATI
Taft Rd.
VAMC
3200 VINE ST.
M.L.K. Dr.
V in e
S t.
ZOO
Jefferson Ave.
UNIV.
HOSPITAL
Mitchell Ave.
R ea di ng
R d.
V ic to ry
P kw
y. XAVIER
UNIV.
N
Areas of Work
N
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Department of Veterans Affairs Medical Center
ARCHITECTURE PLANNING INTERIOR DESIGN
3131 NEWMARK DRIVE, SUITE 200
MIAMISBURG, OHIO 45342
937.461.3290 P
JOHN POE ARCHITECTS
HEAPY ENGINEERING
MECHANICAL ELECTRICAL COMMISSIONING TECHNOLOGY
1400 WEST DOROTHY LANE
DAYTON, OH 45409
937.224.0861 P
937.224.5777 F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
TERRACON CONSULTING, INC.
ENVIRONMENTAL
611 LUNKEN PARK DRIVE
CINCINNATI, OH 45226
513.321.5816 P
513.321.4540 F
SD 35% SCHEMATIC DESIGN 07.24.2020
DD 65% DESIGN DEVELOPMENT 09.02.2020
CD 95% CONSTUCTION DOCUMENTS 10.02.2020
CD 100% CONSTUCTION DOCUMENTS 10.30.2020
BID 100% CONSTUCTION DOCUMENTS 11.04.2020
/4 /2
:0
:3
P
M
Reconfigure 2nd Floor Waiting & Check-In
11/04/2020
COVER SHEET
G001
CVKR
20003.00
539-21-210
Cincinnati VA
Reconfigure 2nd Floor Waiting & Check-In 3200 Vine Street Cincinnati, OH 45220 PROJECT #: 539-21-210
JOSH SCHNEIDER - COR
100% CONSTRUCTION
DOCUMENTS
G001 COVER SHEET
G100 CODE PLAN
G201 PHASING PLANS
G202 PHASING PLANS
AD102 DEMOLITION PLAN
A102-D DIMENSION PLAN
A102-N NOTE PLAN
A122 REFLECTED CEILING PLAN
A401 INTERIOR ELEVATIONS
A501 CASEWORK SECTIONS & DETAILS
A601 WALL TYPES
A611 DOOR SCHEDULE, WINDOW TYPES & DETAILS
AF101-F FLOOR FINISH PLAN & SCHEDULE
AF101-W WALL PROTECTION & WALL FINISH PLANS
AF601 FURNITURE & EQUIPMENT PLAN
FX001 LEGEND, ABBREVIATIONS & INDEX OF DRAWINGS
FX102 SECOND FLOOR PLAN – NEW WORK
P001 LEGEND, ABBREVIATIONS & INDEX OF DRAWINGS
PD102 SECOND FLOOR PLAN - REMOVALS
P102 SECOND FLOOR PLAN – NEW WORK
M001 HVAC LEGEND, INDEX AND GENERAL NOTES
MD102 SECOND FLOOR PLAN - REMOVALS
M102 SECOND FLOOR PLAN – NEW WORK
M501 DETAILS
M502 DETAILS
M601 SCHEDULES
M901 CONTROLS
E001 LEGEND, ABBREVIATIONS & INDEX OF DRAWINGS
ED100 SECOND FLOOR PLAN - REMOVALS
E100 SECOND FLOOR PLAN NEW WORK - LIGHTING
E101 SECOND FLOOR PLAN NEW WORK - POWER & SYSTEMS
T001 TECHNOLOGY LEGEND
T500 TECHNOLOGY DETAILS
T501 SECURITY DETAILS
TA100 SECOND FLOOR PLAN - REMOVALS TECHNOLOGY
TA101 SECOND FLOOR PLAN - NEW WORK TECHNOLOGY
TN101 SIGNALS CLOSET A239 - NEW WORK
TN102 SIGNALS CLOSET A2005 - NEW WORK
GENERAL CONSTRUCTION NOTES
7. CONTRACTOR IS RESPONSIBLE TO VERIFY SIZES OF ALL EQUIPMENT, ETC. TO
BE INSTALLED AS PART OF THIS PROJECT, AND WHERE NECESSARY, MAKE
SPECIAL PROVISIONS TO INSTALL EQUIPMENT THAT IS TOO LARGE TO FIT
THROUGH FINISHED OPENINGS.
8. CONTRACTOR SHALL PROVIDE WOOD BLOCKING AT TOILET ACCESSORIES,
HAND RAILS, BUMPER RAILS, SHELVING, CASEWORK, MOUNTING BRACKETS
AND OTHER WALL MOUNTED ITEMS, AS INDICATED IN THE CONTRACT
DOCUMENTS AND AS RECOMMENDED BY PRODUCT MANUFACTURERS. ALL
WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED.
9. ALL EXPOSED NEW WORK IS TO RECEIVE NEW FINISHES UNLESS
SPECIFICALLY NOTED OTHERWISE. iF NO FINISH IS INDICATED AT A
PARTICULAR SURFACE, CONTRACTOR SHALL PROVIDE FINISH(S) AS
INDICATED AT SIMILAR CONDITIONS.
10. CONTRACTOR SHALL PROVIDE COMPLETE AND FULLY OPERATIONAL
SYSTEMS WHICH COMPLY WITH STATED CODES AND REGULATIONS. WHERE
THE OMISSION OF A PART OR ELEMENT OF A SYSTEM WOULD RESULT IN THE
NON-OPERATION, OR INCORRECT OPERATION OF A SYSTEM, CONTRACTOR
SHALL INCLUDE SAID PART OR ELEMENT AS PART OF THE WORK.
11. ALL PENETRATIONS THROUGH NEW AND/OR EXISTING SMOKE OR FIRE RATED
WALLS SHALL BE SMOKE/FIRE STOPPED AS REQUIRED BY THE RATING OF
THE WALL.
12. FIRE PROTECTION CONTRACTOR'S SPRINKLER DESIGN WILL BE SUBJECT TO
AN INDEPENDENT REVIEW BY A CERTIFIED FIRE PROTECTION ENGINEER
RETAINED BY THE OWNER. THE FIRE PROTECTION CONTRACTOR IS
RESPONSIBLE FOR MAKING ANY REQUIRED CHANGES TO THE DESIGN AS
IDENTIFIED BY THE OWNER'S FIRE PROTECTION ENGINEER AS NECESSARY
FOR COMPLIANCE WITH SPECIFIED NFPA REQUIREMENTS.
* PLEASE NOTE THAT THE TERM PROJECT ENGINEER REFERS TO THE
CONTRACTING OFFICER'S REPRESENTATIVE (C.O.R.).
1. ALL WORK SHALL COMPLY WITH THE LATEST NFPA 101 LIFE SAFETY CODE,
INTERNATIONAL BUILDING CODE, AND OTHER COES AS IDENTIFIED IN VHA
PROGRAM GUIDE PG-18-3, TOPIC 01, CODES, STANDARDS AND EXECUTIVE
ORDERS WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERAN AFFAIRS,
TECHNICAL INFORMATION LIBRRARY WEBSITE.
2. ALL WORK SHALL COMPLY WITH REQUIREMENTS OF THE LATEST
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS) AND
DEPARTMENT OF VETERANS AFFAIRS BARRIER FREE DESIGN GUIDE PG-18-13
WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERANS AFFAIRS
TECHNICAL INFORMATION LIBRARY WEBSITE.
3. CONTRACTOR IS RESPONSIBLE TO VISIT THE SITE, EXAMINE AND ACCEPT
EXISTING CONDITIONS PRIOR TO BIDDING. SITE VISITS TO BE COORDINATED
WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.
4. CONTRACTOR IS RESPONSIBLE TO REPAIR AND/OR REFINISH, TO MATCH
ADJACENT EXISTING SURFACES, ANY EXISTING MATERIALS TO REMAIN THAT
ARE DAMAGED DURING THE COURSE OF DEMOLITION OR NEW WORK.
5. WHERE REMOVAL OF EXISTING WORK IS REQUIRED FOR INSTALLATION OF
NEW WORK, CONTRACTOR SHALL REPAIR EXISTING CONSTRUCTION TO
REMAIN OR PROVIDE NEW CONSTRUCTION TO MATCH EXISTING ADJACENT
SURFACES TO REMAIN.
6. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL CONDITIONS AND
DIMENSIONS PRIOR TO ORDERING, FABRICATING OR INSTALLING NEW
MATERIALS.
DRAWING INDEX
GRAPHIC SYMBOLS
VICINITY MAP
2ND FLOOR KEY PLAN
Revisions Date
1-HR Fire / Smoke Barrier
2-HR Fire / Smoke Barrier
1-HR Fire Barrier
2-HR Fire Barrier
0-HR Smoke Partition
Means of Egress
Egress Capacity
Existing Wall to Remain
New Wall
Suite Designation
CODE LEGEND
Waiting A202
Office C200B
Office C200A
Scheduling Office A253
Stair 5 S*2*5
A/C Shaft
WORK AREA C
WORK AREA B
WORK AREA A
Waiting C202
Reading Rm C201
Women's Toilet A235
Check-In A201
Waiting A2000
Common Path of Travel Max. Allowable = 100' Actual = 46'
Travel Distance to Exit Max. Allowable = 200' Actual = 35'
Travel Distance to Exit Max. Allowable = 200' Actual = 62'
Nuc. Med.
Admin.
C200
Office C203
Greeter Station
A234
Check-In C200C
Shared Break Room A2020
Corridor C*2*15
Corridor C*2*3
Corridor C*2*1
Stair 1 S*2*1Stair 2
S*2*2
Stair 9 S*2*9
Stair 11 S*2*11
Stair 6 S*2*6
Stair 3 S*2*3
Travel Distance to Exit within Non-Patient-Care Suite. Max. Allowable = 100' Actual = 27'
Common Path of Travel Max. Allowable = 100' Actual = 21'
Non-Patient-Care Suite Max. Allowable = 2,500 SF Acutal = 362 SF
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
SD 35% SCHEMATIC DESIGN 07.24.2020
DD 65% DESIGN DEVELOPMENT 09.02.2020
CD 95% CONSTUCTION DOCUMENTS 10.02.2020
CD 100% CONSTUCTION DOCUMENTS 10.30.2020
BID 100% CONSTUCTION DOCUMENTS 11.04.2020
/4 /2
:1
:0
P
M
Reconfigure 2nd Floor Waiting & Check-In
11/04/2020
CODE PLAN
G100
CVKR
20003.00
539-21-210
Cincinnati VA
JOSH SCHNEIDER - COR
100% CONSTRUCTION
DOCUMENTS
N Scale: 1/16" = 1'-0"
CODE PLAN
CODE NOTES
Code: NFPA 101 Life Safety Code (2018 Edition)
Construction Type: Type I (322)
Use Group: Health Care Occupancy
Protection: Fully Suppressed
Area of Work: Building B1, Second Floor Renovations:
Radiology, Nuclear Medicine & Cardiology Spaces = 2568 SF Corridor C*2*1 = 1819 SF Total Renovated Areas = 4387 SF
Chapter 4 - General
• 4.4.2.2 – Prescriptive-based life safety design meeting the requirements of Chapters 1 thru 3, Sections 4.5 thru 4.8, and Chapters 6 thru 43 of this Code shall be deemed to satisfy the provisions of Sections 4.1 and 4.2.
• 4.4.2.3 – Where req’ts in Chapters 11 thru 43 differ from req’ts in Chapters 1 thru 4 and 6 thru 10, the req’ts of Chapters 11 thru 43 shall govern.
• 4.6.1.1 – The authority having jurisdiction (AHJ) shall determine whether the provisions of this Code are met.
• 4.6.7.1 - Rehabilitation category per 43.2.2.1: (4) Reconstruction.
Chapter - 6 Classification of Occupancy and Hazard of Content
6.1.11 B1 Second Floor, Radiology, Nuclear Medicine & Cardiology = Health Care Occupancy
6.2.2.1 – Hazard classification = Ordinary
Chapter 7 - Means of Egress
• 7.1.3.1 - Exit Access Corridors: >30 occup load = 1-hr. fire rating.
Exception 2): not req'd per 38.3.6.1(3).wt
• 7.1.3.2.1 – Exit Separation:
(1)(3b) Connects 4 or more stories (Existing Egress Stairs with automatic sprinkler system): 1-hr. fire rating (NO CHANGE)
(8)(b) Openings in separation wall: fire doors with closers per 7.2.1.8.
• 7.3.1.2 – Occupant Load:
B1 - Second Floor (Renovation):
Business Use - Offices (concentrated) 1254 SF @ 50 sf / occ = 25 occup.
Assembly Use - Waiting / Break Rm (net) 1224 SF @ 15 sf / occ = 81 occup.
Total = 106 occup.
• 7.3.2.2 – Max. projection within means of egress on ea. side: 4-1/2” (38” hgt. max.).
• 7.3.3.1 – Egress capacity (Health Care, sprinklered)
• Table 7.3.3.1- Stairs = .3” per occup; Level components and ramps = .2” per occup.
• 7.4.1.2 – Min. number of means of egress from any story = 2.
(1) Occupant load >500 and <1,000 = 3 exits minimum.
• 7.5.1.2.1 - Corridors to lead to means of egress without passing through any intervening spaces other than corridors, lobbies or spaces permitted to be open to the corridor.
• 7.5.1.2.2 - Corridors not required to be fire resistance rated shall be permitted to open into open floor plan areas.
• Table A.7.6 - Common Path, Dead-End and Travel Distance Limits New Health Care occupancy - Sprinklered
• Common Path Limit = 100'
• Dead-End Limit = 30'
• Travel Distance Limit = 200'
Chapter 8 - Features of Fire Protection:
• Table 8.3.3.2.2 – Min Fire Protection for Openings in Fire-rated Assemblies:
Component Walls Fire Drs Vision Panel (size) FR Vision Panel FR Window Vert. shafts 2 hr 1-1/2 hr Max tested D-H-90 NP (stairs, exits):
Fire Barriers: 2 hr 1-1/2 hr Max tested D-H-90 NP
1 hr 3/4 hr Max tested D-H-45 3/4 hr
Smoke Barriers: 1 hr 1/3 hr Max tested D-20 3/4 hr 1/2 hr 1/3 hr Max tested D-20 1/3 hr
• 8.3.4.2.1 – Firestop Systems – Penetrations that pass thru a barrier shall be protected by a firestop system or device.
• 8.3.4.2.2 – The firestop system or device shall be tested in accordance with ASTM E814.
• 8.3.4.8 – Openings thru fire barriers for air-handling ductwork or air movement shall be protected per 9.2.1.
• 8.4.1 - Smoke Partitions shall limit the transfer of smoke.
• 8.5.1 - Smoke Barriers shall restrict the transfer of smoke and have 1 hour fire resistance rating.
• 8.5.3 - Fire Barriers that meet requirements of Section 8.5 shall be permitted to be used as a smoke barrier.
• 8.7.1.2 - Where protection is provided with AFSS without F.R. separation, space shall be enclosed with smoke partitions per 8.4.
Chapter 9 - Building Service and Fire Protection Equipment
• 9.6.1.3 – Fire Alarm System req’d for life safety shall be per NFPA 70 and 72.
• 9.6.3.1 – Occupant notification shall be provided per 9.6.3, 18.3.4.3.1.
• 9.6.3.4 – Where permitted by Chapters 11 thru 43, a positive alarm sequence shall be permitted per
NFPA 72 (See 18.3.4.3).
• 9.6.4.1 – Emergency Forces notification req’d per 9.6.4 and 18.3.4.3.2.1.
• 9.6.5.1 – Emergency Control functions shall be installed per NFPA 72 as req’d per 9.6.5 and 18.3.4.4.
• 9.6.7.1 – Alarm annunciation is required per 9.6.7 and 18.3.4.3.3.
• 9.7.1.1 – Supervised automatic sprinkler system as req’d by 9.7.1 and 18.3.5.1 and shall comply with
NFPA 13.
• 9.9 - Portable fire extinguishers shall be selected, installed, inspected, and maintained per NFPA 10.
Chapter 10 – Interior Finish, Contents, and Furnishings
• Table A.10.2.2 Interior Finish Classification Limitations for Health Care (Existing)
Exit Access Corridors: Class A or B.
Other Spaces: Class A or B.
• 10.2.3.1 - Interior wall and ceiling finish materials shall be classified in accordance with NFPA 286 and comply with 10.2.3.2.
• 10.2.3.1.2 - Materials tested in accordance with 10.2.3.1.1 and complying with 10.2.3.2 shall be considered also to comply with the requirements of Class A, Class B, or Class C in accordance with 10.2.3.3.
• 10.2.3.3 – Wall and Ceiling – Classifications characteristics:
(1) Class A: Flame spread: 0-25; Smoke dev.: 0-450.
(2) Class B: Flame spread: 26-75; Smoke dev.: 0-450.
(3) Class C: Flame spread: 76-200; Smoke dev.: 0-450.
(4) Existing interior finish exempt from smoke dev. criteria.
• 10.2.7.2 – Floor finish other than carpet: Min. Rad flux: .1 W/ cm².
• 10.2.8.1 – Wall and Ceiling finishes, where sprinkled:
Class C permitted in any location where Class B is req’d.
Class B permitted in any location where Class A is req’d.
• 10.2.8.2 – Floor finishes, where sprinkled:
Class II permitted in any location where Class I is req’d.
Provisions of 10.2.7.2 shall apply where Class II is req’d.
Chapter 18 - New Health Care Occupancies
• 18.1.1.1.4 - The area of work is an existing hospital and therefore falls under Chapter 18.
• Table 18.1.6.1 - Construction Type Limitations: Type I (322), sprinklered, no story limitations.
• 18.1.7 - Occupant Load per Table 7.3.1.2.
• 18.2.2.2.2(1) - Door locking devices that restrict access to a room from the corridor and that are operable only be staff from the cooridor side shall be permitted, provided that such devices to not restrict egress from the room
• 18.2.3.4 - Corridors in hospitals shall be not less than 8 feet in clear an unobstructed width.
• 18.2.5.2 - Dead end corridors shall not exceed 30’.
• 18.2.5.3 - Common path of travel shall not exceed 100’.
• 18.2.5.4 - Every corridor shall have access to not less than two approved exits without passing through any intervening spaces other than corridors or lobbies.
• 18.2.5.6.5 - Rooms within suites shall not be required to an exit access door leading directly to an exit access corridor.
• 18.2.5.7.1.2 - Suite Separation – Suites shall be separated from remainder of the building by walls and doors (0-hr smoke partitions).
• 18.2.5.7.3.1(B) - Suite more than 2500sf requires two exits access doors
• 18.2.5.7.3.3(A) - The portion of travel distance from any point within the suite to an exit door from the suite shall not be more than 100'.
• 18.2.6.2.1 - Travel distance from any point in a room to exit shall not exceed 200’.
• 18.3.4.1 - Health care occupancies shall be provided with a fire alarm system IAW Section 9.6.
• 18.3.5.1 - Building containing health care occupancies shall be protected throughout by approved, supervised automatic sprinkler systems IAW Section 9.7.
• 18.3.5.12 - Portable fire extinguishers shall be provided IAW Section 9.9.
• 18.3.6.2.2 - No fire resistance rating is required for corridor walls.
• 18.3.6.2.3 - Corridor walls shall form a barrier to limit the transfer of smoke but are not required to be smoke barriers or smoke partitions.
• 18.3.6.3.1 - Corridor doors shall be doors constructed to resist the passage of smoke.
• 18.3.7.3 - Smoke barrier shall be constructed IAW Section 8.5 and shall have 1 hour fire resistive rating.
• 18.3.7.6 - Doors in smoke barriers shall have 20 minute fire resistive rating.
Chapter 43 - Building Rehabilitation
• 43.1.2.1 - Any building undergoing repair, renovation, modification, or reconstruction shall comply with both of the following:
(1) Req'ts of the applicable existing occupancy chapters (Chapter 39).
(2) Req'ts of the applicable secton of this Chapter (Sections 43.4 and 43.5).
• 43.4.1 - Renovations & General Req'ts: all new work shall comply with the req'ts of other sections of this Code applicable to existing construction.
• 43.5.1 - Modifications & General Req'ts: all new work shall shall comply with the req'ts of other sections of this Code applicable to new construction.
A/C Shaft
Reception
A202
Break Rm.
A253
File Rm.
C200B
Office
C200A
Reading Rm.
C202
Nuclear Medicine Secretary
C200
Office
C200C
1.12
1.15
1.16
Corridor
C*2*1
Corridor
C*2*3
Corridor
C*2*15
S-5
S-6
1.191.19
1.17
A/C Shaft
Storage
A2020
Reception
A202 Break Rm.
A253
Reading Rm.
C202
Nuclear Medicine Secretary
C200
Office
C200C
File Rm.
C200B
Office
C200A
Imaging Reception
A201
Waiting
A2000
Tlt. Rm.
A253B
Break Rm.
C203
Waiting
C201
Women's Toilet
A235
Corridor
C*2*1
Corridor
C*2*3
Corridor
C*2*15
S-5
S-6
Temporary Construction Barrier.
See Wall Type T1.0
Existing or work completed in previous phase
Area to be renovated in future phase
Area renovated during indicated phase
PHASING LEGEND
Office
C203
Reading Rm
C201
Greeter Station
A234
Women's Toilet
A235
M
IN
T1.0
T1.01.10 1.13
1.14
Check-In
A201
Waiting
A2000
Waiting
A202
T1.0 T1.0
T1.0
T1.0
M
IN
1.13
1.14
Shared Break Room
A2020
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
SD 35% SCHEMATIC DESIGN 07.24.2020
DD 65% DESIGN DEVELOPMENT 09.02.2020
CD 95% CONSTUCTION DOCUMENTS 10.02.2020
CD 100% CONSTUCTION DOCUMENTS 10.30.2020
BID 100% CONSTUCTION DOCUMENTS 11.04.2020
/4 /2
:0
:5
P
M
Reconfigure 2nd Floor Waiting & Check-In
11/04/2020
PHASING PLANS
G201
CVKR
20003.00
539-21-210
Cincinnati VA
JOSH SCHNEIDER - COR
100% CONSTRUCTION
DOCUMENTS
N Scale: 3/32" = 1'-0"1.1
PHASE 1.1 - FLOOR PLAN
N Scale: 3/32" = 1'-0"1.0
EXISTING FLOOR PLAN
NOTES
1.10 Remove portion of wall create 4' wide framed opening.
Finish jamb of opening with gyp bd and paint to match existing condidtions.
1.12 Work in corridor to be completed after hours. Contractor to provide dust separation for the construction area at the beginning of each shift. At the end of each shift, Contractor to remove dust separation and clean work areas.
1.13 Maintain 5' minimum clear egress around all temporary
partitions.
1.14 Construct temporary partitions at the beginning of phase.
Remove once permanent wall and door have been completed within the area.
1.15 Temporary Waiting Room.
1.16 Temporary patient Check-In.
1.17 Temporary Office flex space.
1.19 Contractors to exclusively use service elevators S-5 & S-6 for daily use.
GENERAL PHASING NOTES
A. For temporay partition locations see Demolition Plans. Temporary partitions are suggested locations. Coordinate final location in field with C.O.R.
B. Verify all conditions in the field prior to fabrication, erection and construction.
C. All asbestos containing material (ACM) must be abated per the direction of the C.O.R. and project specification 017419 and local state and federal regulations. Abatement if required is to be scheduled in appropriate sequence with demolition, new construction and project phasing.
D. Coordinate phase completion and start-up with requirements as set forth by the C.O.R. to maintain daily operations to near as normal as possible.
E. Coordinate location of job dumpster with the C.O.R. so as to disrupt daily operations as little as possible.
F. Coordinate access to all phases of construction, deliveries, and debris removal with the C.O.R. See General Requirements.
G. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. Confirm all locations with the C.O.R.
H. Existing HVAC, medical gases, sprinklers and water supply to be maintained throughout as required during each phase of construction.Coordinate phasing with Mechanical and Plumbing contractor. Support and protect all lines during each phase of construction. See MEP Drawings.
J. Provide and maintain negative air pressure at all construction.
Coordinate with HVAC contractor. See HVAC plans for temporary venting requirements and duct locations.
K. Phasing drawings to be used in conjunction with entire set of construction drawings.
L. Existing power must be maintained throughout as required during each phase of construction.Coordinate phasing with Electrical Contractor. Coordinate power turnover with requirements as dictated by the C.O.R. See Electrical Drawings.
M. Coordinate sequence construction with C.O.R. so that only one side of any corridor in use is obstructed at any one time.
N. Coordinate all operating work hours involving the generation of excessive noise with C.O.R. so as to minimize disturbances to patients. Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the C.O.R.
P. All temporary walls to be wall type T1.0 unless otherwise noted.
Temporary wall removal to take place after standard operating hours.
Q. Night Work noted to take place after hours to be scheduled between 7:00 PM - 5:30 AM Monday-Friday, all day Saturday and Sunday.
R. Temporary construction wayfinding signs shall be provided and installed by VA. Locations to be coordinated with C.O.R.
Temporary Construction Barrier.
See Wall Type T1.0
Existing or work completed in previous phase
Area to be renovated in future phase
Area renovated during indicated phase
PHASING LEGEND
A/C Shaft
Reception
A202
Break Rm.
A253
1.16
1.181.18
1.17
1.17
Corridor
C*2*1
Corridor
C*2*3
Corridor
C*2*15
S-5
S-6
1.191.19
Check-In
A201
Waiting
A202
Waiting
A2000
Waiting
A2000
T1.0
Office
C200B
Office
C200A
Waiting
C202
Nuc. Med.
Admin.
C200
Check-In
C200C
Office
C203
Reading Rm
C201
Greeter Station
A234
Women's Toilet
A235
M
IN
T1.0T1.01.12
1.13
1.14
Shared Break Room
A2020
A/C Shaft
1.12
1.17
Corridor
C*2*15
Corridor
C*2*3
Corridor
C*2*1
S-5
S-6
1.191.19
Office
C200B
Office
C200A
Waiting
C202
Nuc. Med.
Admin.
C200
Check-In
C200C
Office
C203
Reading Rm
C201
Greeter Station
A234
Women's Toilet
A235
Shared Break Room
A2020
Check-In
A201
Waiting
A202
Waiting
A2000
M
IN
Waiting
A202
Waiting
A2000
T1.0T1.0
T1.0
1.13
1.14
Scheduling Office
A253
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
SD 35% SCHEMATIC DESIGN 07.24.2020
DD 65% DESIGN DEVELOPMENT 09.02.2020
CD 95% CONSTUCTION DOCUMENTS 10.02.2020
CD 100% CONSTUCTION DOCUMENTS 10.30.2020
BID 100% CONSTUCTION DOCUMENTS 11.04.2020
/4 /2
:1
:2
P
M
Reconfigure 2nd Floor Waiting & Check-In
11/04/2020
PHASING PLANS
G202
CVKR
20003.00
539-21-210
Cincinnati VA
JOSH SCHNEIDER - COR
100% CONSTRUCTION
DOCUMENTS
NOTES
1.12 Work in corridor to be completed after hours. Contractor to provide dust separation for the construction area at the beginning of each shift. At the end of each shift, Contractor to remove dust separation and clean work areas.
1.13 Maintain 5' minimum clear egress around all temporary
partitions.
1.14 Construct temporary partitions at the beginning of phase.
Remove once permanent wall and door have been completed within the area.
1.16 Temporary patient Check-In.
1.17 Temporary Office flex space.
1.18 Temporary Shared Wating Room
1.19 Contractors to exclusively use service elevators S-5 &
S-6 for daily use.
GENERAL PHASING NOTES
A. For temporay partition locations see Demolition Plans. Temporary partitions are suggested locations. Coordinate final location in field with C.O.R.
B. Verify all conditions in the field prior to fabrication, erection and construction.
C. All asbestos containing material (ACM) must be abated per the direction of the C.O.R. and project specification 017419 and local state and federal regulations. Abatement if required is to be scheduled in appropriate sequence with demolition, new construction and project phasing.
D. Coordinate phase completion and start-up with requirements as set forth by the C.O.R. to maintain daily operations to near as normal as possible.
E. Coordinate location of job dumpster with the C.O.R. so as to disrupt daily operations as little as possible.
F. Coordinate access to all phases of construction, deliveries, and debris removal with the C.O.R. See General Requirements.
G. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. Confirm all locations with the C.O.R.
H. Existing HVAC, medical gases, sprinklers and water supply to be maintained throughout as required during each phase of construction.Coordinate phasing with Mechanical and Plumbing contractor. Support and protect all lines during each phase of construction. See MEP Drawings.
J. Provide and maintain negative air pressure at all construction.
Coordinate with HVAC contractor. See HVAC plans for temporary venting requirements and duct locations.
K. Phasing drawings to be used in conjunction with entire set of construction drawings.
L. Existing power must be maintained throughout as required during each phase of construction.Coordinate phasing with Electrical Contractor. Coordinate power turnover with requirements as dictated by the C.O.R. See Electrical Drawings.
M. Coordinate sequence construction with C.O.R. so that only one side of any corridor in use is obstructed at any one time.
N. Coordinate all operating work hours involving the generation of excessive noise with C.O.R. so as to minimize disturbances to patients. Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the C.O.R.
P. All temporary walls to be wall type T1.0 unless otherwise noted.
Temporary wall removal to take place after standard operating hours.
Q. Night Work noted to take place after hours to be scheduled between 7:00 PM - 5:30 AM Monday-Friday, all day Saturday and Sunday.
R. Temporary construction wayfinding signs shall be provided and installed by VA. Locations to be coordinated with C.O.R.
N Scale: 3/32" = 1'-0"1.2
PHASE 1.2 - FLOOR PLAN
N Scale: 3/32" = 1'-0"1.3
PHASE 1.3 - FLOOR PLAN
A/C Shaft
2.51
2.52
2.55
2.71
2.632.63
2.71
2.63
2.71 2.63
2.71
2.71
2.61
2.61
2.71
2.71
2.61
2.61
2.61
2.61
2.62
2.71
2.71
2.63
2.71
2.62 2.53
2.54 2.54
2.53
2.55
2.55
2.71
2.62
2.63 2.71 2.71
2.62
2.532.53
2.56
2.64
2.71
2.53
2.412.58
2.62
2.722.72
2.72
2.72
2.61
2.71
2.64 2.71
2.57
2.31
B
A
C
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
SD 35% SCHEMATIC DESIGN 07.24.2020
DD 65% DESIGN DEVELOPMENT 09.02.2020
CD 95% CONSTUCTION DOCUMENTS 10.02.2020
CD 100% CONSTUCTION DOCUMENTS 10.30.2020
BID 100% CONSTUCTION DOCUMENTS 11.04.2020
/4 /2
:0
:5
P
M
Reconfigure 2nd Floor Waiting & Check-In
11/04/2020
DEMOLITION PLAN
AD102
CVKR
20003.00
539-21-210
Cincinnati VA
JOSH SCHNEIDER - COR
100% CONSTRUCTION
DOCUMENTS
GENERAL DEMOLITION NOTES
A. Remove all partitions shown with dashed line. Repair wall and floor finishes to match adjacent surfaces at areas of removal or scheduled new surfaces as required.
B. Remove all borrowed lights, doors and hollow metal frames where indicated with dashed line. Unused hardware shall be turned over to Owner. Box hardware before giving to Owner.
C. Remove wall-hung toilet room accessories and medical equipment as required and turn over to Owner.
D. See Plumbing, HVAC and Electrical Drawings for removal work associated with those trades.
E. Computer and communication cables and/or other wiring, piping, tubing, etc. serving other areas and functions located above ceiling or in walls of area to be remodeled shall be maintained during demolition/construction process. Coordinate any required changes to these systems with the C.O.R.
F. Remove all abandoned cables and/or other wiring, piping, tubing, etc. serving other areas and functions located above ceiling.
G. Repair existing walls to match adjacent undisturbed wall where cabinets, countertops, etc. are shown to be removed.
H. Prepare walls and floor slabs as required to receive new finish materials where existing finish is indicated to be removed.
J. Remove corner guards in areas to be remodeled.
K. Remove existing grab bars, mirrors, soap & towel dispensers and all other wall mounted toilet room accessories. Removed items shall be turned over to Owner.
L. Remove all whiteboards, shelving, cabinets and suport brackets mounted to walls. Removed items shall be turned over to Owner.
M. Remove all systems furniture. Removed items shall be turned over to Owner.
N. Remove all signage and artwork in corridors. Removed items shall be turned over to Owner.
P. Remove all wall protection and handrails in areas to be remodeled.
Q. Coordinate demolition with project phasing.
R. Any removed all ectronic devices, including but not limited to, wireless access points, PA speakers, checkpoint sensors, checkpoint repeaters and checkpoint modems shall be turned over to Owner.
NOTES
2.31 Existing concrete floor. Prep floor as required for new
flooring finish.
2.41 Remove existing toilet room plumbing fixtures and
accessories for construction. Salvage and store for reinstallation. Fixtures and accessroies to be reinstalled at original location.
2.51 Remove toilet partition.
2.52 Remove and salvage lockers. Store and protect during
construction to be reinstalled in new location.
2.53 Remove casework.
2.54 Remove countertop.
2.55 Remove window.
2.56 Remove existing masonry wall. Remove CMU up to bottom
of structure. Remove brick up to existing support angle.
2.57 Remove chair rail wall protection.
2.58 Remove wall tile. Patch and repair wall as required to
receive new finishes.
2.61 Remove VCT flooring & base.
2.62 Remove sheet vinyl flooring & base.
2.63 Remove carpet & base.
2.64 Remove tile flooring & base.
2.71 Remove ACT ceiling tiles & grid.
2.72 Remove portion of existing ceiling grid and tile required for construction of new ceilings. See Reflected Ceiling Plan.
N Scale: 1/8" = 1'-0"
DEMOLITION PLAN - AREA A
N Scale: 1/8" = 1'-0"
DEMOLITION PLAN - AREA B
N Scale: 1/8" = 1'-0"
DEMOLITION PLAN - AREA C
KEY PLAN
B
A
C
Office
C200A
A/C Shaft
Office
C200B
Reading Rm
C201
Waiting
C202
Women's Toilet
A235
2' - 6" 5' - 4" 5' - 8 7/8" 5' - 8 7/8" 2' - 6" +/- 10' - 3 1/2"
Waiting
A2000
Check-In
A201
Waiting
A202 5
/2
/8
/4
" 11' - 8 7/8"
Align
Align
Align
Align
Align
Align
7' - 5 3/4" +/- 6' - 4 7/8"
/8
/8
Office
C203
Greeter Station
A234
Align
+/- 16' - 9 5/8" 17' - 6 1/2"
/8
45.00°
Nuc. Med.
Admin.
C200
Check-In
C200C
EQ. EQ.
1' - 0"
/8
Corridor
C*2*1
Align
4' - 2 1/2"
8' - 8"
5' - 2"
+/- 10' - 9 1/2"
Align
Align
5' - 5 3/4"
2' - 0"
/8
Align
Align
6' - 6"
Scheduling Office
A253
Align
Shared Break Room
A2020
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
SD 35% SCHEMATIC DESIGN 07.24.2020
DD 65% DESIGN DEVELOPMENT 09.02.2020
CD 95% CONSTUCTION DOCUMENTS 10.02.2020
CD 100% CONSTUCTION DOCUMENTS 10.30.2020
BID 100% CONSTUCTION DOCUMENTS 11.04.2020
/4 /2
:1
:0
P
M
Reconfigure 2nd Floor Waiting & Check-In
11/04/2020
DIMENSION PLAN
A102-D
CVKR
20003.00
539-21-210
Cincinnati VA
JOSH SCHNEIDER - COR
100% CONSTRUCTION
DOCUMENTS
GENERAL NOTES
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. All wood blocking to be fire retardent treated.
D. All partitions shall be type 'S1.0' unless noted otherwise.
KEY PLAN
N Scale: 1/8" = 1'-0"
DIMENSION PLAN - AREA A
N Scale: 1/8" = 1'-0"
DIMENSION PLAN - AREA B
N Scale: 1/8" = 1'-0"
DIMENSION PLAN - AREA C
UP
A
C
Waiting
A202
Office
C200B Office
C200A
A/C Shaft
Waiting
A2000
Check-In
A201
Reading Rm
C201
Women's Toilet
A235
Corridor
C*2*1
Waiting
C202
Office
C203
Greeter Station
A234
Nuc. Med.
Admin.
C200
Check-In
C200C
S2.0S2.0S2.3
A201
C201 C203
C200 C200B
C200A
S3.0
B
A
A
A
A235
S2.3
A401
A
A401
A
A
A401
A401
A401
S2.3
S2.3
S5.0S5.0A401
A
A401
B
A401
C
B
E E E
F F
CC
D
S2.3S2.3S2.3S2.3
S3.0
12.52
Scheduling Office
A253 S2.0S2.0
A253
S6.0
S6.0
S2.3S2.3
S2.3S2.3
S2.3S2.3
A2020
A
8.50
8.50
G
G
Shared Break Room
A2020
S2.3
S2.3
A611
A611
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
SD 35% SCHEMATIC DESIGN 07.24.2020
DD 65% DESIGN DEVELOPMENT 09.02.2020
CD 95% CONSTUCTION DOCUMENTS 10.02.2020
CD 100% CONSTUCTION DOCUMENTS 10.30.2020
BID 100% CONSTUCTION DOCUMENTS 11.04.2020
/4 /2
:1
:1
P
M
Reconfigure 2nd Floor Waiting & Check-In
11/04/2020
NOTE PLAN
A102-N
CVKR
20003.00
539-21-210
Cincinnati VA
JOSH SCHNEIDER - COR
100% CONSTRUCTION
DOCUMENTS
NOTES
GENERAL NOTES
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. All wood blocking to be fire retardent treated.
D. All partitions shall be type 'S1.0' unless noted otherwise.
8.50 Install translucent vinyl film on inside face of glazing on the bottom portion of the storefront windows.
12.52 All existing toilet fixtures and accessories to be reinstalled at orginal location.
KEY PLAN
N Scale: 1/8" = 1'-0"
NOTE PLAN - AREA A
N Scale: 1/8" = 1'-0"
NOTE PLAN - AREA B
N Scale: 1/8" = 1'-0"
NOTE PLAN - AREA C
REFLECTED CEILING PLAN LEGEND
Recessed downlight fixture
Supply Air Diffuser
2' x 2' Return Air Grille2' x 2' light fixture
2' x 2' acoustical tile ceiling
Gypsum board ceiling / soffit - painted
Surface mounted light fixture
Acoustic wood ceiling planks
Recessed LED strip fixture
1' x 2' Return Air Grille
B
A
C
A201 A202
A2000
C201
A235
C202
C200B
C200A
C*2*1
7'-10"
C203
A234
C200C
C200
AWC-1
7'-8"
8'-0"
8'-0"
8'-0"
ACT-1
ACT-1
ACT-1
ACT-1 ACT-1
8'-0"8'-0"
ACT-1
8'-0" 8'-0"
ACT-1
ACT-1
8'-0"
8'-0" 8'-0"
ACT-1
7'-8"
ACT-1
6'-10"
12.13
12.1312.13
12.13
12.13
A122
ACT-1
12.13
Align
A122
Sim
A122
Sim
A122
Sim
A122
Sim
A122
1' - 0"
Align 8'-0"
P-2
P-5
P-2
C*2*1
C*2*1
8'-0" ACT-1
7'-8"
C*2*1
Align
P-5
Align
A253
7'-10"
ACT-1
A2020
ACT-1
9'-3"
12.01
12.01
VARIES - SEE PLAN
9.02
9.41
9.02
9.91
9.02
9.91
9.41
9.21
S E
E P
L A
N
9.21
S E
E P
L A
N
9.41
1/4" Typ.
9.83
9.92
9.82
9.84
8"
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
SD 35% SCHEMATIC DESIGN 07.24.2020
DD 65% DESIGN DEVELOPMENT 09.02.2020
CD 95% CONSTUCTION DOCUMENTS 10.02.2020
CD 100% CONSTUCTION DOCUMENTS 10.30.2020
BID 100% CONSTUCTION DOCUMENTS 11.04.2020
/4 /2
:1
:2
P
M
Reconfigure 2nd Floor Waiting & Check-In
11/04/2020
REFLECTED CEILING PLAN
A122
CVMW
20003.00
539-21-210
Cincinnati VA
JOSH SCHNEIDER - COR
100% CONSTRUCTION
DOCUMENTS
GENERAL NOTES
A. All wood blocking shall be fire retardant.
B. Light fixtures, sprinkler heads, speakers, and HVAC devices shall be located as close as possible to the center of acoustical ceiling panels. Confirm any deviation from this with the Project Engineer.
C. See P, M, E and FP drawings for additional information regarding final information and quantites of fixtures/devices to be installed in ceiling.
D. See Electrical Drawings for lighting specifications.
E. Ceilings in Corridor C*2*1 are existing to remain. Contractor to modify and repair existing corridor ceilings only as necessary to complete new work.
NOTES
9.02 3 5/8" non-structural metal framing @ 16" o.c.
9.21 5/8" Type X gypsum board.
9.41 Suspended acoustic ceiling tile/grid ACT-1. See Room
Finish Schedule.
9.82 Acoustical wood planks (AWC-1). Fully sealed, sound
insulated, resonant cavity overlayed with micro-perforated multi-ply surface, See Room Finish Schedule.
9.83 Vertical wood veneer trim. Finish to match AWC-1.
9.84 Suspended grid system with bayonet clips.
9.91 Angled metal framing to structure above.
9.92 1/4" closed spline reveal. Spline finish to be painted black.
12.01 Manual roller window shades (WT-1).
12.13 Horizontal blinds (WT-2).
KEY PLAN
N Scale: 1/8" = 1'-0"
REFLECTED CEILING PLAN - AREA A
N Scale: 1/8" = 1'-0"
REFLECTED CEILING PLAN - AREA B
N Scale: 1/8" = 1'-0"
REFLECTED CEILING PLAN - AREA C
Scale: 1 1/2" = 1'-0"1
GYP. BD. CEILING DETAIL
Scale: 1 1/2" = 1'-0"2
WOOD CEILING DETAIL
OPEN
P-1P-1
RB-1
P-1
P-1
CG-1
P-1 P-2 P-1
OPEN
CG-1
CG-1
RB-1
PL-1
SS-1
CG-1CG-1 CG-1
E E
10.01
RB-1
CG-1 RB-1
SS-1
PL-1
RB-1
26.0126.01
RB-1
RB-1
OPEN
P-1
CG-1
P-1
P-3
P-3 P-3
P-3
P-3
HR-1 HR-1
A235OPEN
P-3
PL-1
SS-2
SS-1
CG-1 CG-1 CG-1CG-1
CG-1
AWC-1
10.01
RB-1
RB-1
1747A237A236A
RB-1RB-1RB-1
RB-1
OPEN
P-1
RB-1
P-1 P-1
CG-1
P-1 P-1
RB-1 P-1
OPEN
EG-1 EG-1 CG-1
RB-1
PL-1
SS-1
EEE
P-2
CG-1
10.01
HR-1
P-1
A203206
CG-1SS-1
PL-1
RB-1
SS-1
PL-1
RB-1
26.0126.0126.01
AA
WP-1
RB-1
9.959.95 9.959.95
OPEN
PT-2
P-1
RB-1
P-1
P-1
HR-1
CG-1
CG-1
CG-1
CG-1
RB-1
ELEVATOR
RB-1RB-1
RB-1RB-1 RB-1RB-1
ELEVATOR ELEVATOR ELEVATOR
9.95
WP-1
RB-1
CG-1P-1
P-1
OPENWP-1
RB-1
EG-1
P-1
PT-1
P-1
A
B
PL-1
SS-1
PL-1
2' - 6"
3 5/8" 2' - 6"
W1 W1
B1 B8
3 2
2' - 6" 2' - 6"
B7
2' - 6" 2' - 6"
W1
PL-1
A2020
P-1
RB-2
SS-2
A401
A
A
Greeter Station
A234
A501
A501
2' - 5"
5' - 2"
ALIGN
12.32
A401
A
A501
A501
A
EQ. A 4 7/8" EQ. A
16' - 4 3/4"
EQ. B EQ. B
A501
A501
12.32 12.32
1' - 6" 1' - 6"
12.32 12.32
B2
2' - 6" 1"
SS-1
PL-1
RB-1
2' - 6" B2
1"
RB-1
PL-1
SS-1
SS-2
PL-1
PL-1
SS-1
PL-1
RB-1
SS-2
P-1
PL-1
P-1
SS-1
P-2 P-2
RB-2
EE
OPEN
OPEN
OPEN
OPEN
EG-1
RB-1
P-1
2' - 2"
C
D
RB-1
A611
8.51
P-1
RB-1
P-1
RB-2
CG-1
8.51
A401
A501
A501
A501
16' - 9 3/4"
EQ. A 4 7/8" EQ. A 4 7/8" EQ. A
A
A
12.32 12.32 12.32
P-2
SS-1
PL-1
RB-2
P-2
EG-1 EG-1
P-2
EEE
/8
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
SD 35% SCHEMATIC DESIGN 07.24.2020
DD 65% DESIGN DEVELOPMENT 09.02.2020
CD 95% CONSTUCTION DOCUMENTS 10.02.2020
CD 100% CONSTUCTION DOCUMENTS 10.30.2020
BID 100% CONSTUCTION DOCUMENTS 11.04.2020
/4 /2
:0
:2
P
M
Reconfigure 2nd Floor Waiting & Check-In
11/04/2020
INTERIOR ELEVATIONS
A401
NHMW
20003.00
539-21-210
Cincinnati VA
JOSH SCHNEIDER - COR
100% CONSTRUCTION
DOCUMENTS
NOTES
8.51 1/4" tempered glass.
9.95 Reveal.
10.01 Large wall signage, owner provided/installed.
12.32 Wire management grommet. Coordinate exact location
with COR.
26.01 Light fixture. See Electrical Drawings.
7 5
Scale: 1/4" = 1'-0"16
TOILET A235 - TYP. WALL TILE PATTERN
Scale: 1/4" = 1'-0"8
BREAK ROOM A2020
A
B
91011
14 13 12
Scale: 1/4" = 1'-0"
CORRIDOR C*2*1
Scale: 1/4" = 1'-0"
GREETER STATION
Scale: 1/4" = 1'-0"
CORRIDOR C*2*1
Scale: 1/4" = 1'-0"
CORRIDOR C*2*1
Scale: 1/4" = 1'-0"
NUC. MED CHECK-IN
C
Scale: 1/4" = 1'-0"
RADIOLOGY CHECK-IN
ENLARGED PLAN VIEW
ENLARGED PLAN VIEW ENLARGED PLAN VIEW
B1B8
Sink
Microwave
1' - 1" 3" 8"
1"
/4
2' - 1"
12.20
12.24
12.27
12.19
/4
2' - 1"
12.20
12.17
12.24
12.22
9.60
12.51
3"
1"
12.21
B7
12.19
12.20
12.29
12.30
12.22
12.31
12.21
9.60
3"
2' - 1"
1"
/4
1' - 7"
/4
3"
12.19
12.20
12.29
12.30
12.22
12.31
12.21
9.60
1"
B2
/4
W1
26.01
12.29
12.30
12.22
12.21
12.09
1' - 2"
12.31
6.03
26.01
12.30
12.29
12.31
12.21
6.03
12.09
W2
1' - 2"
/4
12.21
12.20
12.20
12.21
12.28
5.06
5 1/8"
6.03
8"2' - 0"
9.60
12.21
26.01
9.60
2"
/4
/4
9.60
2' - 5 3/4"
12.20
12.28
/4
12.21 1"
12.21
9.60
5.065 1/8"
2"
2' - 8"
/4
3 1/4"
12.2012.32
26.01
12.21
9.60
9.60
6.03
5.06
2"
5 1/8"
12.21
12.2812.28
12.20
12.28
12.32
/4
9.60
12.21
2"
12.19
2' - 0"
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
SD 35% SCHEMATIC DESIGN 07.24.2020
DD 65% DESIGN DEVELOPMENT 09.02.2020
CD 95% CONSTUCTION DOCUMENTS 10.02.2020
CD 100% CONSTUCTION DOCUMENTS 10.30.2020
BID 100% CONSTUCTION DOCUMENTS 11.04.2020
/4 /2
:0
:2
P
M
Reconfigure 2nd Floor Waiting & Check-In
11/04/2020
CASEWORK SECTIONS & DETAILS
A501
NHMW
20003.00
539-21-210
Cincinnati VA
JOSH SCHNEIDER - COR
100% CONSTRUCTION
DOCUMENTS
NOTES
5.06 3-5/8" cold formed metal framing @ 16" O.C. See Structural Drawings.
6.03 Wood blocking.
9.60 Resilient base. See Room Finish Schedule.
12.09 Soffit panel. Plastic laminate over 3/4" plywood. Match finish to cabinet body finish.
12.17 Side splash. See Elevations for locations.
12.19 Applied solid surface backsplash.
12.20 Solid surface material over 3/4" plywood substrate, 1/4" eased edge.
12.21 Plastic laminate over 3/4" particle board.
12.22 Plastic lamiante adjustable clad shelf, 3/4" particle board w/finishes on all 6 surfaces on metal standards. Provide 1" thick shelves when span exceeds 32".
12.24 Apron. Plastic laminate over 3/4" particle board.
12.27 Removable panel with concealed fasteners: Plastic laminate over 3/4" plywood.
12.28 Metal in-wall recessed countertop support bracket.
12.29 4" wire pull. [Recessed pull.]
12.30 Self-latching, key-operated lock.
12.31 5 Knuckle hinge.
12.32 Wire management grommet. Coordinate exact location with
COR.
12.51 Provide openning for wire management.
26.01 Light fixture. See Electrical Drawings.
Scale: 1" = 1'-0"
CASEWORK SECTIONS
Scale: 1" = 1'-0"1
CASEWORK SECTION
Scale: 1" = 1'-0"2
CASEWORK SECTION
Scale: 1" = 1'-0"3
CASEWORK SECTION
Scale: 1" = 1'-0"4
CASEWORK SECTION
S2.0
9.21
9.02
7.82
7.82
4 1/4"
9.80
S3.0
1 1/2"
9.05
9.21
7.82
7.82
T1.0
9.21
9.02
9.80
4 7/8"
7.80
7.80
9.42
1-HR RATED
FIRE BARRIER
UL #U465
9.16
S2.3
9.21
9.01
7.82
7.82
3 1/8"
9.80
S6.0
5/8"
7.82
7.82
9.21
9.80
2.03
S1.0
4 7/8"
9.219.21
9.02
9.80
7.82
7.82
STRUCTURE ABOVE
FIN. CEILING
FLOOR SLAB
S5.0
5 5/8"
9.219.21
9.02
9.80
7.82
7.82
6.09 Reading Room Side of Wall
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
SD 35% SCHEMATIC DESIGN 07.24.2020
DD 65% DESIGN DEVELOPMENT 09.02.2020
CD 95% CONSTUCTION DOCUMENTS 10.02.2020
CD 100% CONSTUCTION DOCUMENTS 10.30.2020
BID 100% CONSTUCTION DOCUMENTS 11.04.2020
/4 /2
:0
:3
P
M
Reconfigure 2nd Floor Waiting & Check-In
11/04/2020
WALL TYPES
A601
CVKR
20003.00
539-21-210
Cincinnati VA
JOSH SCHNEIDER - COR
100% CONSTRUCTION
DOCUMENTS
2.03 Existing wall to remain.
6.09 3/4" fire retardant treated plywood.
7.80 Continuous fire-rated sealant @ rated walls each side.
7.82 Continuous acoustic sealant @ non-rated walls.
9.01 2 1/2" non-structural metal framing @ 16" o.c.
9.02 3 5/8" non-structural metal framing @ 16" o.c.
9.05 7/8" [Z or hat] furring channel @ 16" o.c.
9.16 Fire retardant plastic sheeting sealed to prevent passage of air.
9.21 5/8" Type X gypsum board.
9.42 Paint Temporary Partitions to match adjacent walls.
9.80 Acoustic insulation
NOTES
Scale: 1" = 1'-0"
WALL TYPES
SEE PLANSEE PLAN
1/2" 1/2"
1/2"1/2"
H1
J1
8.02
9.21
9.80
8.02
9.09
9.21
9.80
8.08
9.21
9.80
8.08
9.09
9.21
9.80
8.04
S1 H1
J1
9.08
7.82 7.82
9.08
7.82 1/2" 1/2"
7.82
1/2" 1/2"
2"
SEE
SCHED. 2"
S E
E S
C H
E D
U L E
3 1/4" SEE SCHEDULE 3 1/4"
/4
S E
E S
C H
E D
U L E
SEE SCHED.
S E
E S
C H
E D
U L E
F
4' - 6"
A611
A611
A611
Finish Floor
A
PLAN
SEE
Check-In
7.83
9.08
6.08
8.26
8.51
P L A
N
S E
E
Check-In
6.08
7.83
8.51
8.26
1/2"
1/2"
Check-In
8.26
8.51
7.83
9.34
6.08
PLAN
SEE
3' - 0"
B
A611
A611
A611
E
3/8"See Plan1/8"
A611
Open
Open
6.27
2"
8.63
8.51
9.21
PLAN
SEE
A611
2' - 0"
C
A611
A611
D
2' - 0"
A611
A611
A611
6.08
9.28
7.83
8.26
8.55 2' - 0"
P L A
N
S E
E
7.83
8.26 8.55
8.24
8.26
7.83
8.26
8.55
/2
2.04
A611
3/8"See Plan1/8"
Open
Open
F
6.27
2.092.09
2.11
2.10
8.50
A611 9.34
2.10
2.09
1/2"
9.34
2.09
8.508.50
6.08
2.04
2.03
PLAN
SEE
2.09
9.60
/4
7.89
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
SD 35% SCHEMATIC DESIGN 07.24.2020
DD 65% DESIGN DEVELOPMENT 09.02.2020
CD 95% CONSTUCTION DOCUMENTS 10.02.2020
CD 100% CONSTUCTION DOCUMENTS 10.30.2020
BID 100% CONSTUCTION DOCUMENTS 11.04.2020
/4 /2
:0
:4
P
M
Reconfigure 2nd Floor Waiting & Check-In
11/04/2020
DOOR SCHEDULE, WINDOW TYPES
& DETAILS
A611
CVKR
20003.00
539-21-210
Cincinnati VA
JOSH SCHNEIDER - COR
100% CONSTRUCTION
DOCUMENTS
DOOR SCHEDULE
WT
BETWEEN DOOR DESCRIPTION FRAME DESCRIPTION
FIRE
RATING
HDWE
SET
CARD
READER REMARKSRM RM TYPE MAT'L
SIZE
TYPE MAT'L HEAD JAMB# W H T
A201 A202 A201 F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H1 J1 2 Yes
A235 C*2*1 A235 F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H1 J1 5 Existing with New Hardware
A253 C*2*3 A253 F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H1 J1 3 Existing with New Hardware
A2020 C*2*15 A2020 F HM 2 4'-0" 7'-0" 1 3/4" 1 HM H1 J1 6 Existing with New Hardware
C200 C*2*1 C200 F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H1 J1 1 Yes
C200A C200 C200A F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H1 J1 4
C200B C200 C200B F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H1 J1 4
C200C C200C C200 F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H1 J1 3
C201 C*2*1 C201 F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H1 J1 1 Yes
C203 C*2*1 C203 F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H1 J1 4
NOTES
2.03 Existing wall to remain.
2.04 Existing concrete floor.
2.09 Existing storefront window to remain.
2.10 Existing storefront glazing to remain.
2.11 Existing storefront spandral glazing to remain.
6.08 Fire retardant treated wood blocking.
6.27 Check-In counter. See Interior Elevations & Details.
7.82 Continuous acoustic sealant @ non-rated walls.
7.83 Continuous sealant each side.
7.89 Continuous sealant along aluminum frame and solid surface window sill joint.
8.02 Hollow metal frame.
8.04 Hospital stops @ all interior hollow metal frames.
8.08 Double egress hollow metal frame.
8.24 Clear anodized aluminum frame closure end cap.
8.26 4-1/2" clear anodized aluminum window frame.
8.50 Install translucent vinyl film on inside face of glazing on the bottom portion of the storefront windows.
8.51 1/4" tempered glass.
8.55 Laminated glass with translucent frosted interlayer with 40% opacity.
8.63 90 degree glazing clamp wall mounted bracket.
9.08 Metal framing box header.
9.09 Double metal framing at jambs, typ.
9.21 5/8" Type X gypsum board.
9.28 Gypsum board ceiling.
9.34 Solid surface window sill trim (SS-1).
9.60 Resilient base. See Room Finish Schedule.
9.80 Acoustic insulation
Scale: 1 1/2" = 1'-0"
H.M. FRAME DETAILS
N.T.S.Scale:
H.M. FRAME TYPES
N.T.S.Scale:
DOOR TYPES
Scale: 1/2" = 1'-0"
WINDOW TYPES
Scale: 1 1/2" = 1'-0"1
WINDOW HEAD
Scale: 1 1/2" = 1'-0"2
WINDOW JAMB
Scale: 1 1/2" = 1'-0"3
WINDOW SILL
Scale: 3" = 1'-0"7
BRACKET DETAIL
Scale: 1 1/2" = 1'-0"4
WINDOW HEAD
Scale: 1 1/2" = 1'-0"5
WINDOW HEAD
Scale: 1 1/2" = 1'-0"6
WINDOW SILL
G
Scale: 1 1/2" = 1'-0"8
BREAK RM SILL
C
Waiting
A202
Office
C200B Office
C200A
A/C Shaft
Waiting
A2000
Check-In
A201
Reading Rm
C201
Women's Toilet
A235 Corridor
C*2*1
Waiting
C202
Office
C203
Greeter Station
A234
Nuc. Med.
Admin.
C200
Check-In
C200C
LVT-1 LVT-1
LVT-2
LVT-1LVT-2
LVT-1 LVT-1
PT-1
LVT-1
LVT-1
LVT-2
LVT-2
Corridor
C*2*1
Corridor
C*2*1
LVT-2
LVT-2
LVT-2
Scheduling Office
A253
LVT-1
Shared Break Room
A2020
LVT-1
WALL TILE TO PAINTED GYP. WALL TILE TO FLOOR TILEWALL TILE OUTSIDE
CORNER EDGE PROFILE
9.31
9.31
9.66
9.31
9.65 9.31
9.31
9.67
WALL TILE TO
EXISTING CEILING
9.31
9.65
WALL TILE TO
RESILIENT WALL BASE
9.65
9.31
9.60
9.94
9.65
9.33
WALL TILE INSIDE CORNER
EDGE PROFILE
9.31
9.31
9.67
PORCELAIN TILE TO RESILIENT FLOOR
9.51
9.13 9.32
RESILIENT FLOOR TO RESILIENT FLOOR
9.50 9.51
9.63
J O H N
A
P O E
IO
H O
F O
E T A T
S
R EG
IS
E T
R E D
R A
C H
TI
E
CT
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .