Addendum 2_Revised Drawings.pdf
PDF 5 MB Posted
- Solicitation number
- 36C24926R0037_0001
About this file
This document is a set of architectural construction drawings for the renovation of Building 1 Primary Care at Memphis VAMC (Veterans Affairs Medical Center), project number 614-17-113. The drawings include demolition plans, finish plans, reflected ceiling plans, and fire protection plans for the first floor of the facility.
The demolition plan (AD101) identifies areas for removal including walls, flooring, ceiling construction, door frames, plumbing fixtures, and wall-mounted accessories throughout the project boundary. Key demolition notes specify that existing structural systems shall remain unaltered, ceiling tiles must be carefully removed and stored for reinstallation, floor slabs require removal of flooring and adhesive with leveling to manufacturer specifications, and the contractor must coordinate all demolition work with new construction design intent and engineering drawings. Special attention is required for the existing dumbwaiter shaft removal (with above-shaft support and fire rating maintenance), knee wall and radiator removal, and utility rerouting to facilitate new construction. The finish plans (AF101, AF102) establish wall, floor, and ceiling finishes using designated material codes including paint colors (P-1, P-5, PT-3), resilient flooring (RES-1), ceramic tile (C-1), terrazzo (TER-1, TER-2, TER-3), luxury vinyl tile (LVT-1, LVT-2, LVT-3), and quarry tile (QT-1). The reflected ceiling plan (AS111) specifies 2x2 acoustical ceiling tiles at 9'-0" height in most areas with 8'-0" heights in select locations, gypsum board ceilings in specific areas, and coordination requirements with mechanical, electrical, and plumbing (MEP) systems. The fire protection plan (FX102) shows sprinkler head locations and coverage throughout the first floor with corresponding technical notes for installation and maintenance.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CW132
CW133
CW134CW135
CW128
CW127ACW127
CW124
CW126C
CW126E
CW114
CW173
CW166A
CW170
CW166
CW120B
CW119
P-7P-6
CW110
NO 2
CW123
CW111A
CW105
CW120
CW120A
CW166B
CW113
CW165
CW171
CW172
CW126A
126D
CW127B
CW126
CW125 CW123B CW123A
CW139
CW138CW137CW136
CW104A
CW102BCW101B
NO 1
NO 3
CW175CW176CW177
CW178
CW179
CW180
CW140
CW140B
CW140A
CW140
CW141CW142
CW143
CW144
CW145CW146CW147
CW148
CW150
CW149
CW152C
CW152BCW152A
CW152E
CW152
CW151
CW149B
CW149A
CW149E
CW149C
CW183
CW191
CW191A
CW187
CW186CW185 CW185A
CW185B
CW190
CW189
CW184
CW182
CW181
CW174
CW196
CW196A
CW195
CW160A
CW160C
CW160D
CW160B
CW154
CW160
CW163
CW164
CW197
CW194B
CW194
CW192
CW194B CW194C
CW193
CW140D
CW140C
CW194A
FECELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
IMMUNOLOGY
LOBBY
TOILET
PTSD OFFICE
PTSD OFFICE
PTSD RESIDENTIAL
OFFICE
AGENT
CASHIER
ELIGIBILITY /
TRAVEL OFFICE
ELIGIBILITY /
TRAVEL OFFICE
PATIENT
ADVOCATE OFFICE
OFFICE
TELE OPERATOR
TESTINGTESTING
E C
OFFICE
MENS
TOILET
EXAM
ELEVATORELEVATOR
T CE C
ELEVATORELEVATOR
STAIR
YELLOW
WAITING
LOW VISION EXAM
EXAM
EYE CLINIC WAITING
EXAM
STORAGE
HAC
WOMENS TOILET
ELIGIBILITY OFFICE
TELECOM STORAGE HEAD CLERK
HEALTH
BENEFIT
SECTION OFFICE
ELIGIBILITY /
TRAVEL OFFICE
PATIENT
ADVOCATE OFFICE
PATIENT
ADVOCATE
OFFICE
SOCIAL
WORKER ADMIN
OFFICE
PTSD OFFICEPTSD OFFICE
EXAMPTSD OFFICEPTSD OFFICE
CORRIDOR
OFFICE
OPTOMETRY OFFICE
TOILET
ULTRASOUND-3
READINGREADING RM
CORRIDOR
STORAGE
CLINICAL
PHARMACY
EDUCATIONAL
CO-ORDINATOR
OPTOMETRY OFFICE
TC
TC
ELECTRICAL
STAIR
ELEVATORELEVATOR
STORAGE
CASE LAB
HEMATOLOGY
CASE LAB
CHEMISTRY SUPV
WOMENS TOILET
CARE LABANCILLARY TESTING OFFICE
FILES
STORAGE RM
NIGHT SUPVSUPV
TELECOM
SHAFT
SPECIAL
CARE LAB
CARE/PED
TECH OFFICE
HAC
SHAFT
SUPPLYOFFICEOFFICEMICROSCOPIC TEACHINGRESIDENTS
FROZEN
SECTION
CLOSET
BREAK RM
EXAM
ELEVATOR
WAITING
ACCESSION AREA
TOILET TOILET
BLOOD DWG
STORAGE
STORAGERECEPTION OFFICE
COPY
PGM
ASST
ADMINISTRATIVE CLERKS-4
SECYCHIEF
OFFICE-1PATHOLOGY OFFICE-2OFFICE-3OFFICE-4OFFICE-5
OFFICE
ELECTRICAL
FILE
B-V CODE
EXPANSION
CO-ORDINATOR
BREAK RM
MENS TOILET
BLOOD BANK
TB
REFMYC
OFFICE
MICROBIOLOGY
STAIR
AUTOCLAVE
FLOW
CYTOMETER
OFFICE
PCR RM
CONFERENCE
RECEPTION
MICROSCOPE RM
CASE LAB
KEY PLAN
N
G
A
B
C
D
E
F
H
1 2 3 4 5 6 7 8 9 10 11
AD401
1 4
1 4
10 101010101010101010
5 5
N
DEMOLITION GENERAL NOTES
COORDINATE DEMOLITION WITH NEW CONSTRUCTION. ALL DEMOLITION AND REPAIR
NECESSARY TO COMPLETE NEW AND REMODEL CONSTRUCTION SHALL BE PROVIDED.
CONTRACTOR SHALL REMOVE EXISTING IMPROVEMENTS WHETHER OR NOT
SPECIFICALLY INDICATED ON THE DRAWINGS TO FACILITATE THE COMPLETION OF ALL
REQUIRED WORK. CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL QUANTITIES AND
ITEMS REQUIRED TO BE REMOVED.
REFER TO ARCHITECTURAL SYMBOLS ON SHEET AS001 FOR DEMOLITION SYSTEMS AND
DRAWING NOMENCLATURE.
THE EXISTING STRUCTURAL SYSTEM WITHIN THE PROJECT BOUNDARY SHALL REMAIN
UNALTERED, UNLESS OTHERWISE NOTED WITHIN THESE DOCUMENTS.
SURFACES TO BE CUT AND CONDITIONS UNDER WHICH CUTTING IS TO BE PREFORMED
SHALL BE REVIEWED BY CONTRACTOR PRIOR TO CUTTING TO VERIFY NO UNSAFE OF
UNSATISFACTORY CONDITIONS EXIST. SUCH CONDITIONS SHALL BE RECTIFIED BEFORE
WORK MAY PROCEED.
EXTENTS OF DEMOLITION SHALL BE COORDINATED WITH AS101 - FIRST FLOOR
ARCHITECTURAL PLAN AND AS102 - FIRST FLOOR DIMENSION PLAN AS WELL AS ANY AND
ALL ENGINEERING DRAWINGS AND OR ADDITIONAL INFORMATION.
DIMENSIONS SHOWN FOR EXISTING CONSTRUCTION TO BE DEMOLISHED ARE
APPROXIMATE AND ARE INTENDED TO GIVE A GENERAL SCOPE OF WORK TO BE
REMOVED OR TEMPORARILY REMOVED TO ACCOMMODATE NEW CONSTRUCTION.
COORDINATE DEMOLITION WORK WITH DESIGN INTENT OF NEW CONSTRUCTION TO
PROVIDE ADEQUATE AREA FOR THIS WORK.
CONTRACTORS SHALL REMOVE INDICATED DEMOLITION OF CONSTRUCTION ASSEMBLIES
IN THEIR ENTIRETY, UNLESS OTHERWISE NOTED, TO ACCOMMODATE NEW
CONSTRUCTION. EXISTING IMMEDIATELY ADJACENT CONSTRUCTION TO REMAIN SHALL
BE PREPARED TO RECEIVE NEW CONSTRUCTION AS NECESSARY.
MAKE ALL DEMOLITION CLEAN AND COMPLETE IN A MANNER TO RECEIVE NEW FINISHES.
DEMOLITION SHOULD BE PERFORMED IN A MANNER SUCH THAT THE CONTRACTOR CAN
SEAMLESSLY PATCH NEW WORK TO BE SMOOTH AND UNDETECTABLE.
ABOVE CEILING WORK WHERE CEILINGS ARE TO REMAIN, CEILING TILES SHALL BE
REMOVED AND STORED IN A SAFE MANNER UNTIL CEILING TILES CAN BE REINSTALLED.
DAMAGED AND BROKEN CEILING TILES SHALL BE REPLACED BY CONTRACTOR. GYPSUM
BOARD CEILINGS SHALL BE PATCHED AND PAINTED TO SEAMLESSLY MATCH EXISTING
CEILING COLOR FOLLOWING ABOVE CEILING DEMOLITION ACTIVITY. THIS SHALL INCLUDE
REPAIR TO THE CEILING GRID, SUSPENSION SYSTEM AND ALL ASSOCIATED ASSEMBLIES
AS WELL AS THE REPLACEMENT OF DAMAGED CEILING PANELS, WITHIN AND BEYOND
PROJECT LIMITS.
COORDINATE FULL SCOPE OF DEMOLITION WORK WITH ENGINEERING AND VENDOR
DRAWINGS.
WHERE EXISTING FLOOR FINISH IS REMOVED, FLOORING AND ADHESIVE SHALL BE
REMOVED TO PROVIDE A CLEAN FLOOR SLAB. FLOOR SLAB SHALL BE FILLED/ LEVELED
TO PROVIDE A LEVEL FINISH PER NEW FLOORING MANUFACTURES RECOMMENDATIONS.
REFER TO SPECIFICATION 09 05 16.
COORDINATE SCOPE OF FLOORING REMOVAL WITH HAZARDOUS MATERIAL REMOVAL
PLAN HA101.
WALLS SHALL BE REMOVED THROUGHOUT PROJECT BOUNDARY UNLESS OTHERWISE
INDICATED.
COLUMN WRAPS SHALL BE REMOVED FROM EXISTING COLUMNS THROUGHOUT PROJECT
BOUNDARY UNLESS OTHERWISE INDICATED.
FLOORING AND WALL BASE SHALL BE REMOVED THROUGHOUT PROJECT BOUNDARY
UNLESS OTHERWISE INDICATED.
REMOVE WALL MOUNTED ACCESSORIES AND MOUNTING HARDWARE THROUGHOUT
PROJECT BOUNDARY UNLESS NOTED OTHERWISE.
REMOVE ALL PLUMBING FIXTURES AND ASSOCIATED ACCESSORIES THROUGHOUT
PROJECT BOUNDARY UNLESS OTHERWISE NOTED. REFER TO PLUMBING PLAN FOR
ADDITIONAL INFORMATION.
REMOVE DOOR LEAVES, FRAMES AND HARDWARE THROUGHOUT PROJECT BOUNDARY
UNLESS OTHERWISE NOTED.
COORDINATE REMOVAL OF OXYGEN, VACUUM, NURSE CALL AND SPECIAL ELECTRICAL
ITEM WITH ENGINEERING DRAWINGS.
REMOVE EXISTING WALL PROTECTION, CORNER GUARDS, HANDRAILS AND/ OR
GUARDRAILS THROUGHOUT PROJECT BOUNDARY UNLESS OTHERWISE NOTED.
ALL CEILING CONSTRUCTION WITHIN THE PROJECT BOUNDARY SHALL BE COMPLETELY
REMOVED. ALL CEILING IMMEDIATELY ADJACENT TO THE PROJECT BOUNDARY SHALL
REMAIN. EXISTING CEILING THAT ARE AFFECTED BY NEW CONSTRUCTION SHALL BE
PRESERVED AND REPAIRED AS NECESSARY.
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
DEMOLITION PLAN NOTES
THIS AREA IS WITHIN THE CONSTRUCTION AREA BUT IS TO REMAIN PRESERVED AND
ACCESSIBLE AT ALL TIMES. ALL EXITING AREA TO BE PROTECTED AND PRESERVED
FOR THE ENTIRE DURATION OF THE PROJECT.
EXISTING WALL ADJACENT TO CONSTRUCTION AREA TO REMAIN. PRESERVED
EXISTING WALL TO REMAIN AND PREPARE FOR NEW FINISH. CAUTION TO BE USED
WHEN REMOVING IMMEDIATELY ADJACENT CONSTRUCTION. MAINTAIN INTEGRITY OF
SEPARATION AS REQUIRED BY EXISTING CONDITIONS.
EXISTING WALL TO REMAIN. EXISTING SURFACE TO REMAIN TO BE CLEANED,
PATCHED, REPAIRED AND PREPPED FOR NEW FINISH.
EXISTING DOOR AND FRAME TO REMAIN. EXISTING HARDWARE TO BE REPLACE TO
MATCH NEW HARDWARE IN THE REMAINDER OF THE NEW CONSTRUCTION AND THE
VA STANDARDS.
EXISTING FIRE RATED SHAFT WALL CONSTRUCTION TO REMAIN.
EXISTING FIBER OPTIC LINE LOCATION TO REMAIN AND BE MODIFIED
EXISTING OPENING IN SLAB ABOVE AND/OR BELOW TO BE INFILLED. SEE DETAIL
13/AS501 FOR MORE INFORMATION.
EXISTING STOREFRONT TO REMAIN. REMOVE ALUMINUM INFILL PANEL AND PREP
OPENING TO RECEIVE NEW GLAZING. REFER TO FLOOR PLAN AS101 FOR MORE
INFORMATION.
EXISTING SHEAR WALL TO REMAIN.
EXISTING KNEE WALL CONSTRUCTION, RADIATOR AND ACCESSORIES TO BE
REMOVED. EXISTING SURFACE TO REMAIN TO BE CLEANED, PATCHED, REPAIRED
AND PREPPED FOR NEW FINISH. COORDINATE DEMOLITION WITH MECHANICAL
DRAWINGS. REFER TO AS101 FOR MORE INFORMATION.
EXISTING DUMBWAITER SHAFT SHALL BE REMOVED. EXISTING SHAFT ABOVE SHALL
BE SUPPORTED AND MAINTAINED. FIRE RATING AT FLOOR SLAB SHALL BE
MAINTAINED. SEE DETAIL 13/AS501 FOR MORE INFORMATION.
CONTRACTOR SHALL REMOVE WALLS IN THIS AREA AND SURVEY ANY AND ALL
UTLITIES ASSOCIATED IN THIS AREA. ALL UTILITIES TO REMAIN SHALL BE
REROUTEDTO FACILITATE NEW PLAN. REFER TO MEP DRAWINGS FOR MORE
INFORMATION.
EXISTING TILE FLOORING TO BE REMOVED. PREP SURFACE TO RECEIVE NEW FINISH.
REFER TO FINISH SCHEDULE FOR MORE INFORMATION.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
Building Number
JLG DMC
A u to d e s k D o c s
/1 .1
V A
M e m p h is
B ld g
P ri m a ry
C a re
/1 .1
A v
.r v t
/1
/2
:4
:4
P
M
AD101
FIRST FLOOR DEMOLITION PLAN
GUIDON DESIGN, INC
1221 N PENNSYLVANIA STEET
INDIANAPOLIS, IN 46202
317.800.6388
JAMES GOODEN
CMTA CONSULTING ENGINEERS, INC
10411 MEETING STREET
PROSPECT, KY 40059
502.326.3085
ANDREW MYERS
RENOVATE BUILDING 1 PRIMARY
CARE
MEMPHIS VAMC
614-17-113
RYAN STEPHENS,
COR MEMPHIS, TN
05/23/2023
BID SET
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"AD101
1 FIRST FLOOR - DEMOLITION PLAN
Revisions: Date:
E
F
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR ELEVATOR
BREAK RM
CW195
EXAM
CW194B
RECEPTION
CW194A
N
KEY PLAN
N
DEMOLITION GENERAL NOTES
COORDINATE DEMOLITION WITH NEW CONSTRUCTION. ALL DEMOLITION AND REPAIR
NECESSARY TO COMPLETE NEW AND REMODEL CONSTRUCTION SHALL BE PROVIDED.
CONTRACTOR SHALL REMOVE EXISTING IMPROVEMENTS WHETHER OR NOT
SPECIFICALLY INDICATED ON THE DRAWINGS TO FACILITATE THE COMPLETION OF ALL
REQUIRED WORK. CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL QUANTITIES AND
ITEMS REQUIRED TO BE REMOVED.
REFER TO ARCHITECTURAL SYMBOLS ON SHEET AS001 FOR DEMOLITION SYSTEMS AND
DRAWING NOMENCLATURE.
THE EXISTING STRUCTURAL SYSTEM WITHIN THE PROJECT BOUNDARY SHALL REMAIN
UNALTERED, UNLESS OTHERWISE NOTED WITHIN THESE DOCUMENTS.
SURFACES TO BE CUT AND CONDITIONS UNDER WHICH CUTTING IS TO BE PREFORMED
SHALL BE REVIEWED BY CONTRACTOR PRIOR TO CUTTING TO VERIFY NO UNSAFE OF
UNSATISFACTORY CONDITIONS EXIST. SUCH CONDITIONS SHALL BE RECTIFIED BEFORE
WORK MAY PROCEED.
EXTENTS OF DEMOLITION SHALL BE COORDINATED WITH AS101 - FIRST FLOOR
ARCHITECTURAL PLAN AND AS102 - FIRST FLOOR DIMENSION PLAN AS WELL AS ANY AND
ALL ENGINEERING DRAWINGS AND OR ADDITIONAL INFORMATION.
DIMENSIONS SHOWN FOR EXISTING CONSTRUCTION TO BE DEMOLISHED ARE
APPROXIMATE AND ARE INTENDED TO GIVE A GENERAL SCOPE OF WORK TO BE
REMOVED OR TEMPORARILY REMOVED TO ACCOMMODATE NEW CONSTRUCTION.
COORDINATE DEMOLITION WORK WITH DESIGN INTENT OF NEW CONSTRUCTION TO
PROVIDE ADEQUATE AREA FOR THIS WORK.
CONTRACTORS SHALL REMOVE INDICATED DEMOLITION OF CONSTRUCTION ASSEMBLIES
IN THEIR ENTIRETY, UNLESS OTHERWISE NOTED, TO ACCOMMODATE NEW
CONSTRUCTION. EXISTING IMMEDIATELY ADJACENT CONSTRUCTION TO REMAIN SHALL
BE PREPARED TO RECEIVE NEW CONSTRUCTION AS NECESSARY.
MAKE ALL DEMOLITION CLEAN AND COMPLETE IN A MANNER TO RECEIVE NEW FINISHES.
DEMOLITION SHOULD BE PERFORMED IN A MANNER SUCH THAT THE CONTRACTOR CAN
SEAMLESSLY PATCH NEW WORK TO BE SMOOTH AND UNDETECTABLE.
ABOVE CEILING WORK WHERE CEILINGS ARE TO REMAIN, CEILING TILES SHALL BE
REMOVED AND STORED IN A SAFE MANNER UNTIL CEILING TILES CAN BE REINSTALLED.
DAMAGED AND BROKEN CEILING TILES SHALL BE REPLACED BY CONTRACTOR. GYPSUM
BOARD CEILINGS SHALL BE PATCHED AND PAINTED TO SEAMLESSLY MATCH EXISTING
CEILING COLOR FOLLOWING ABOVE CEILING DEMOLITION ACTIVITY. THIS SHALL INCLUDE
REPAIR TO THE CEILING GRID, SUSPENSION SYSTEM AND ALL ASSOCIATED ASSEMBLIES
AS WELL AS THE REPLACEMENT OF DAMAGED CEILING PANELS, WITHIN AND BEYOND
PROJECT LIMITS.
COORDINATE FULL SCOPE OF DEMOLITION WORK WITH ENGINEERING AND VENDOR
DRAWINGS.
WHERE EXISTING FLOOR FINISH IS REMOVED, FLOORING AND ADHESIVE SHALL BE
REMOVED TO PROVIDE A CLEAN FLOOR SLAB. FLOOR SLAB SHALL BE FILLED/ LEVELED
TO PROVIDE A LEVEL FINISH PER NEW FLOORING MANUFACTURES RECOMMENDATIONS.
REFER TO SPECIFICATION 09 05 16.
COORDINATE SCOPE OF FLOORING REMOVAL WITH HAZARDOUS MATERIAL REMOVAL
PLAN HA101.
WALLS SHALL BE REMOVED THROUGHOUT PROJECT BOUNDARY UNLESS OTHERWISE
INDICATED.
COLUMN WRAPS SHALL BE REMOVED FROM EXISTING COLUMNS THROUGHOUT PROJECT
BOUNDARY UNLESS OTHERWISE INDICATED.
FLOORING AND WALL BASE SHALL BE REMOVED THROUGHOUT PROJECT BOUNDARY
UNLESS OTHERWISE INDICATED.
REMOVE WALL MOUNTED ACCESSORIES AND MOUNTING HARDWARE THROUGHOUT
PROJECT BOUNDARY UNLESS NOTED OTHERWISE.
REMOVE ALL PLUMBING FIXTURES AND ASSOCIATED ACCESSORIES THROUGHOUT
PROJECT BOUNDARY UNLESS OTHERWISE NOTED. REFER TO PLUMBING PLAN FOR
ADDITIONAL INFORMATION.
REMOVE DOOR LEAVES, FRAMES AND HARDWARE THROUGHOUT PROJECT BOUNDARY
UNLESS OTHERWISE NOTED.
COORDINATE REMOVAL OF OXYGEN, VACUUM, NURSE CALL AND SPECIAL ELECTRICAL
ITEM WITH ENGINEERING DRAWINGS.
REMOVE EXISTING WALL PROTECTION, CORNER GUARDS, HANDRAILS AND/ OR
GUARDRAILS THROUGHOUT PROJECT BOUNDARY UNLESS OTHERWISE NOTED.
ALL CEILING CONSTRUCTION WITHIN THE PROJECT BOUNDARY SHALL BE COMPLETELY
REMOVED. ALL CEILING IMMEDIATELY ADJACENT TO THE PROJECT BOUNDARY SHALL
REMAIN. EXISTING CEILING THAT ARE AFFECTED BY NEW CONSTRUCTION SHALL BE
PRESERVED AND REPAIRED AS NECESSARY.
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
DEMOLITION PLAN NOTES
THIS AREA IS WITHIN THE CONSTRUCTION AREA BUT IS TO REMAIN PRESERVED AND
ACCESSIBLE AT ALL TIMES. ALL EXITING AREA TO BE PROTECTED AND PRESERVED
FOR THE ENTIRE DURATION OF THE PROJECT.
EXISTING WALL ADJACENT TO CONSTRUCTION AREA TO REMAIN. PRESERVED
EXISTING WALL TO REMAIN AND PREPARE FOR NEW FINISH. CAUTION TO BE USED
WHEN REMOVING IMMEDIATELY ADJACENT CONSTRUCTION. MAINTAIN INTEGRITY OF
SEPARATION AS REQUIRED BY EXISTING CONDITIONS.
EXISTING WALL TO REMAIN. EXISTING SURFACE TO REMAIN TO BE CLEANED,
PATCHED, REPAIRED AND PREPPED FOR NEW FINISH.
EXISTING DOOR AND FRAME TO REMAIN. EXISTING HARDWARE TO BE REPLACE TO
MATCH NEW HARDWARE IN THE REMAINDER OF THE NEW CONSTRUCTION AND THE
VA STANDARDS.
EXISTING FIRE RATED SHAFT WALL CONSTRUCTION TO REMAIN.
EXISTING FIBER OPTIC LINE LOCATION TO REMAIN AND BE MODIFIED
EXISTING OPENING IN SLAB ABOVE AND/OR BELOW TO BE INFILLED. SEE DETAIL
13/AS501 FOR MORE INFORMATION.
EXISTING STOREFRONT TO REMAIN. REMOVE ALUMINUM INFILL PANEL AND PREP
OPENING TO RECEIVE NEW GLAZING. REFER TO FLOOR PLAN AS101 FOR MORE
INFORMATION.
EXISTING SHEAR WALL TO REMAIN.
EXISTING KNEE WALL CONSTRUCTION, RADIATOR AND ACCESSORIES TO BE
REMOVED. EXISTING SURFACE TO REMAIN TO BE CLEANED, PATCHED, REPAIRED
AND PREPPED FOR NEW FINISH. COORDINATE DEMOLITION WITH MECHANICAL
DRAWINGS. REFER TO AS101 FOR MORE INFORMATION.
EXISTING DUMBWAITER SHAFT SHALL BE REMOVED. EXISTING SHAFT ABOVE SHALL
BE SUPPORTED AND MAINTAINED. FIRE RATING AT FLOOR SLAB SHALL BE
MAINTAINED. SEE DETAIL 13/AS501 FOR MORE INFORMATION.
CONTRACTOR SHALL REMOVE WALLS IN THIS AREA AND SURVEY ANY AND ALL
UTLITIES ASSOCIATED IN THIS AREA. ALL UTILITIES TO REMAIN SHALL BE
REROUTEDTO FACILITATE NEW PLAN. REFER TO MEP DRAWINGS FOR MORE
INFORMATION.
EXISTING TILE FLOORING TO BE REMOVED. PREP SURFACE TO RECEIVE NEW FINISH.
REFER TO FINISH SCHEDULE FOR MORE INFORMATION.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
Building Number
JLG DMC
A u to d e s k D o c s
/1 .1
V A
M e m p h is
B ld g
P ri m a ry
C a re
/1 .1
A v
.r v t
/1
/2
:4
:4
P
M
AD401
ENLARGED DEMOLITION PLAN
GUIDON DESIGN, INC
1221 N PENNSYLVANIA STEET
INDIANAPOLIS, IN 46202
317.800.6388
JAMES GOODEN
CMTA CONSULTING ENGINEERS, INC
10411 MEETING STREET
PROSPECT, KY 40059
502.326.3085
ANDREW MYERS
RENOVATE BUILDING 1 PRIMARY
CARE
MEMPHIS VAMC
614-17-113
RYAN STEPHENS,
COR MEMPHIS, TN
05/23/2023
BID SET
FULLY SPRINKLERED
SCALE: 3/8" = 1'-0"AD401
1 ENLARGED PLAN @ EXISTING DUMBWAITERS & FIBER LINE CLOSET
KEY PLAN
N
PACT TOILET
CW183
STORAGE
CW160G
TELE-HEALTH
CW160B
TELE-RETINAL
CW160A
TEAM WORK AREA
CW160
TELE-HEALTH
CW160D
HYBRID EXAM
CW160E
SOILED
CW161
CLEAN
CW162
HYBRID EXAM
CW186
HYBRID EXAM
CW150S
HYBRID EXAM
CW150RHYBRID EXAM
CW150Q
WOMEN EXAM
CW150P
WOMEN EXAM
CW150N
WOMEN'S TOILET
CW150O
HYBRID EXAM
CW150M
HYBRID EXAM
CW150L
HYBRID EXAM
CW150K
HYBRID EXAM
CW150J
PROCEDURE
CW150H
PROCEDURE TOILET
CW150I
HYBRID EXAM
CW150G
HYBRID EXAM
CW150F
HYBRID EXAM
CW150E
HYBRID EXAM
CW150D
HYBRID EXAM
CW140Q
HYBRID EXAM
CW150C
HYBRID EXAM
CW150B
HYBRID EXAM
CW150A
HAC
CW171
PATIENT CORRIDOR
CWC9
PATIENT CORRIDOR
CWC4
WOMEN EXAM
CW140J
WOMEN TOILET
CW140I
WOMEN EXAM
CW140H
HYBRID EXAM
CW140G
PACT TOILET
CW140U
HYBRID EXAM
CW140F
HYBRID EXAM
CW140E
HYBRID EXAM
CW140D
HYBRID EXAM
CW140C
HYBRID EXAM
CW140B
HYBRID EXAM
CW140A
HT / WT
CWC6-A
HYBRID EXAM
CW140T
HYBRID EXAM
CW140S
HYBRID EXAM
CW140R
HT / WT
CWC4-A
PACT TOILET
CW151
HYBRID EXAM
CW140P
HYBRID EXAM
CW140O
HYBRID EXAM
CW140N
HYBRID EXAM
CW140M
HYBRID EXAM
CW140L
HYBRID EXAM
CW140K
FAMILY TOILET
CW174
PATIENT CORRIDOR
CWC6
TEAM WORK AREA
CW140
TEAM WORK AREA
CW150
STAFF LOCKER
CW157
STAFF FEMALE
TOILET
CW158
STAFF MALE TOILET
CW159
PACT WORKROOM
CW142
PACT WORKROOM
CW143
CLEAN
CW144
STAFF FEMALE
TOILET
CW145
STAFF MALE TOILET
CW146
EQUIPMENT
CW147
SHAFT
SOILED
CW149
PACT WORKROOM
CW148
SHAFT
STAFF LOUNGE /
CONFERENCE /
TRAINING ROOM
CW155
STAIR NO. 3
STAFF CORRIDOR
CWC5
FAMILY TOILET
CW175
HT / WT
CWC9-A
FEMALE PUBLIC
TOILET
CW170B
MALE PUBLIC
TOILET
CW170A
STAIR NO. 1
MEDICATION
CW150T
MEDICATION
95-A
RECEPTION
CW180
WAITING AREA
CW170
CORRIDOR
CWC1
CHECK-IN KIOSK
CWC1F
VOLUNTEER
CWC1D
WHEELCHAIR
CWC1E
OFFICE MANAGER
CW153
NURSE MANAGER
CW152
CHIEF MEDICAL
OFFICER
CW154
DATA
CW169
PACT TOILET
CW186
STORAGE
CW185A
SHARED MEDICAL
APPT
CW185
SHARED MEDICAL
APPT
CW184
STORAGE
CW184A
TOILET VESTIBULE
CWC15A
CORRIDOR
CWC13
CORRIDOR
CWC14
AS402
Sim
AS402
Sim
AS402
Sim
AS402
Sim
AS402
Sim
AS402
Sim
AS402
Sim
P-6
P-2
P-2
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6
RWC-2
RWC-2
4 4
HAC
CW187
ELECTRICAL
CW160C
ELECTRICAL
CW160F
P-6
N
EDUCATION
CWC1G
WAITING AREA
CW170
ENTRANCE
VESTIBULE
CWC1A
FINISHES GENERAL NOTES
A
B
C
D
E
F
G
H
I
J
K
L
M
N
WALLS AND INFILL WALL CONSTRUCTION AND FINISHES SHALL BE PROVIDED
FROM WALL CORNER TO WALL CORNER.
REFER TO INTERIOR ELEVATION AS800 SERIES AND ENLARGED PLANS AS400
SERIES FOR ADDITIONAL INFORMATION.
REFER TO FINISH PLANS AF100 SERIES FOR INFORMATION REGARDING
ACCENT PAINT LOCATIONS AND FLOORING PATTERNS.
PROVIDE P-1 ON WALLS AS FIELD COLOR. REFER TO FINISH SCHEDULE AND
FINISH PLANS FOR ACCENT WALL COLOR DESIGNATIONS.
PROVIDE PT-3 ON HOLLOW METAL DOOR AND WINDOW FRAMES IN SEMI-
GLOSS FINISH.
PROVIDE P-5 ON GYPSUM BOARD CEILINGS AND BULKHEADS, UNLESS
OTHERWISE NOTED.
PROVIDE PAINT TO MATCH WALL PAINT ON ALL EXPOSED METAL ACCESS
PANELS, DUCTS AND OTHER MISC. EXPOSED CONSTRUCTION ELEMENTS.
PATCH AND/OR REPAIR, FINISH, AND PAINT ALL WALLS IN AREA OF WORK.
REFER TO INTERIOR ELEVATION SHEET AS801 FOR WALL TILE PATTERN. PAINT
WALLS ABOVE TILE AS IDENTIFIED IN FINISH SCHEDULE.
INSTALL CG-1 ON ALL OUTSIDE CORNERS MOUNTED ABOVE RESILIENT BASE,
UNLESS OTHERWISE NOTED.
INSTALL WALL BASE OVER RIGID WALLCOVERING.
PROVIDE TS-1 BETWEEN CERAMIC TILE FLOORING AND RESILIENT FLOORING.
PROVIDE MANUFACTURER TYPICAL TRIM, TRANSITION, AND FINISHING
ACCESSORIES. EDGES AND JOINT SHALL BE FINISHED SMOOTH AND TO
MANUFACTURER'S INSTRUCTIONS.
PROVIDE ALUMINUM DIVIDER STRIPS IN TERRAZZO AS NECESSARY TO
PREVENT CRACKING.
#FINISH PLAN NOTES
FINISH TOP OF RWC WITH MATCHING TRIM CAP.
DO NOT INSTALL CG-1 THIS CORNER.
ALIGN
MATCH EXISTING.
REFER TO REFLECTED CEILING PLAN FOR RADIUS DIMENSIONS.
PROVIDE THICK ALUMINUM DIVIDER ON CURVE IN TERRAZZO.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
Building Number
JLG DMC
A u to d e s k D o c s
/1 .1
V A
M e m p h is
B ld g
P ri m a ry
C a re
/1 .1
A v
.r v t
/1
/2
:4
:4
P
M
AF101
FIRST FLOOR WALL FINISH PLAN
GUIDON DESIGN, INC
1221 N PENNSYLVANIA STEET
INDIANAPOLIS, IN 46202
317.800.6388
JAMES GOODEN
CMTA CONSULTING ENGINEERS, INC
10411 MEETING STREET
PROSPECT, KY 40059
502.326.3085
ANDREW MYERS
RENOVATE BUILDING 1 PRIMARY
CARE
MEMPHIS VAMC
614-17-113
RYAN STEPHENS,
COR MEMPHIS, TN
05/23/2023
BID SET
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"AF101
1 FIRST FLOOR - WALL FINISH PLAN
PACT TOILET
CW183
STORAGE
CW160G
TELE-HEALTH
CW160B
TELE-RETINAL
CW160A
TEAM WORK AREA
CW160
TELE-HEALTH
CW160D
HYBRID EXAM
CW160E
SOILED
CW161
CLEAN
CW162
HYBRID EXAM
CW186
HYBRID EXAM
CW150S
HYBRID EXAM
CW150RHYBRID EXAM
CW150Q
WOMEN EXAM
CW150P
WOMEN EXAM
CW150N
WOMEN'S TOILET
CW150O
HYBRID EXAM
CW150M
HYBRID EXAM
CW150L
HYBRID EXAM
CW150K
HYBRID EXAM
CW150J
PROCEDURE
CW150H
PROCEDURE TOILET
CW150I
HYBRID EXAM
CW150G
HYBRID EXAM
CW150F
HYBRID EXAM
CW150E
HYBRID EXAM
CW150D
HYBRID EXAM
CW140Q
HYBRID EXAM
CW150C
HYBRID EXAM
CW150B
HYBRID EXAM
CW150A
HAC
CW171
PATIENT CORRIDOR
CWC9
PATIENT CORRIDOR
CWC4
WOMEN EXAM
CW140J
WOMEN TOILET
CW140I
WOMEN EXAM
CW140H
HYBRID EXAM
CW140G
PACT TOILET
CW140U
HYBRID EXAM
CW140F
HYBRID EXAM
CW140E
HYBRID EXAM
CW140D
HYBRID EXAM
CW140C
HYBRID EXAM
CW140B
HYBRID EXAM
CW140A
HT / WT
CWC6-A
HYBRID EXAM
CW140T
HYBRID EXAM
CW140S
HYBRID EXAM
CW140R
HT / WT
CWC4-A
PACT TOILET
CW151
HYBRID EXAM
CW140P
HYBRID EXAM
CW140O
HYBRID EXAM
CW140N
HYBRID EXAM
CW140M
HYBRID EXAM
CW140L
HYBRID EXAM
CW140K
FAMILY TOILET
CW174
PATIENT CORRIDOR
CWC6
TEAM WORK AREA
CW140
TEAM WORK AREA
CW150
STAFF LOCKER
CW157
STAFF FEMALE
TOILET
CW158
STAFF MALE TOILET
CW159
PACT WORKROOM
CW142
PACT WORKROOM
CW143
CLEAN
CW144
STAFF FEMALE
TOILET
CW145
STAFF MALE TOILET
CW146
EQUIPMENT
CW147
SHAFT
SOILED
CW149
PACT WORKROOM
CW148
SHAFT
STAFF LOUNGE /
CONFERENCE /
TRAINING ROOM
CW155
STAIR NO. 3
STAFF CORRIDOR
CWC5
FAMILY TOILET
CW175
HT / WT
CWC9-A
FEMALE PUBLIC
TOILET
CW170B
MALE PUBLIC
TOILET
CW170A
STAIR NO. 1
MEDICATION
CW150T
MEDICATION
95-A
RECEPTION
CW180
WAITING AREA
CW170
CHECK-IN KIOSK
CWC1F
VOLUNTEER
CWC1D
WHEELCHAIR
CWC1E
OFFICE MANAGER
CW153
NURSE MANAGER
CW152
CHIEF MEDICAL
OFFICER
CW154
DATA
CW169
PACT TOILET
CW186
STORAGE
CW185A
SHARED MEDICAL
APPT
CW185
SHARED MEDICAL
APPT
CW184
STORAGE
CW184A
MEDICATION
CW160-A
HAC
CW187
CORRIDOR
CWC14
CORRIDOR
CWC13
ENTRANCE
VESTIBULE
CWC1A
4 4
ELECTRICAL
CW160C
1' - 6"
VIF
22' - 0" 1' - 6"
VIF
20' - 8 1/4" 1' - 6"
VIF
20' - 7 3/8" 1' - 6"
VIF
20' - 2" 1' - 6" 21' - 7 3/4" 1' - 6"
1'
V
IF
1'
1/ 4"V
IF
5'
/8
1' - 6"
VIF
19' - 11 3/4" 1' - 6"
VIF
20' - 2" 1' - 6"
VIF
20' - 2" 1' - 6"
VIF
20' - 2" 1' - 6"
VIF
30' - 9 3/8" 1' - 6"
1' - 6"
VIF
26' - 10"
1' - 6"
VIF
23' - 7 5/8"
1' - 6"
VIF
5' - 11 5/8" 1' - 6"
VIF
26' - 0" 1' - 6"
VIF
26' - 0" 1' - 6"
VIF
7' - 2 3/8" 1' - 6"
2'
/2
V
IF
/8
1'
1' - 6" 5' - 1" 1' - 6"
V
IF
/8
1'
V
IF
1'
V
IF
/4
1'
4' - 6"
VIF
9' - 1 1/2"
1'
3'
1'
1' - 7" 3' - 0"
1' - 7"
1'
3'
1'
1'
3'
1'
1' - 6" 3' - 0"
1' - 6"
2' - 3" 17' - 2" 4' - 6" 14' - 10 1/8" 2' - 0"
V
IF
1'
7/ 8"
6'
4'
6'
4'
4'
2'
2' - 0"
VIF
10' - 10 7/8" 4' - 6" 10' - 7" 2' - 0"
N
CORRIDOR
CWC1
ELECTRICAL
CW160F
TOILET VESTIBULE
CWC15A
KEY PLAN
N
FINISHES GENERAL NOTES
A
B
C
D
E
F
G
H
I
J
K
L
M
N
WALLS AND INFILL WALL CONSTRUCTION AND FINISHES SHALL BE PROVIDED
FROM WALL CORNER TO WALL CORNER.
REFER TO INTERIOR ELEVATION AS800 SERIES AND ENLARGED PLANS AS400
SERIES FOR ADDITIONAL INFORMATION.
REFER TO FINISH PLANS AF100 SERIES FOR INFORMATION REGARDING
ACCENT PAINT LOCATIONS AND FLOORING PATTERNS.
PROVIDE P-1 ON WALLS AS FIELD COLOR. REFER TO FINISH SCHEDULE AND
FINISH PLANS FOR ACCENT WALL COLOR DESIGNATIONS.
PROVIDE PT-3 ON HOLLOW METAL DOOR AND WINDOW FRAMES IN SEMI-
GLOSS FINISH.
PROVIDE P-5 ON GYPSUM BOARD CEILINGS AND BULKHEADS, UNLESS
OTHERWISE NOTED.
PROVIDE PAINT TO MATCH WALL PAINT ON ALL EXPOSED METAL ACCESS
PANELS, DUCTS AND OTHER MISC. EXPOSED CONSTRUCTION ELEMENTS.
PATCH AND/OR REPAIR, FINISH, AND PAINT ALL WALLS IN AREA OF WORK.
REFER TO INTERIOR ELEVATION SHEET AS801 FOR WALL TILE PATTERN. PAINT
WALLS ABOVE TILE AS IDENTIFIED IN FINISH SCHEDULE.
INSTALL CG-1 ON ALL OUTSIDE CORNERS MOUNTED ABOVE RESILIENT BASE,
UNLESS OTHERWISE NOTED.
INSTALL WALL BASE OVER RIGID WALLCOVERING.
PROVIDE TS-1 BETWEEN CERAMIC TILE FLOORING AND RESILIENT FLOORING.
PROVIDE MANUFACTURER TYPICAL TRIM, TRANSITION, AND FINISHING
ACCESSORIES. EDGES AND JOINT SHALL BE FINISHED SMOOTH AND TO
MANUFACTURER'S INSTRUCTIONS.
PROVIDE ALUMINUM DIVIDER STRIPS IN TERRAZZO AS NECESSARY TO
PREVENT CRACKING.
#FINISH PLAN NOTES
FINISH TOP OF RWC WITH MATCHING TRIM CAP.
DO NOT INSTALL CG-1 THIS CORNER.
ALIGN
MATCH EXISTING.
REFER TO REFLECTED CEILING PLAN FOR RADIUS DIMENSIONS.
PROVIDE THICK ALUMINUM DIVIDER ON CURVE IN TERRAZZO.
LVT-1
LVT-2
LVT-3
TER-1
RES-1
WSF-1C-1
QT-1
TER-3
TER-2
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
Building Number
JLG DMC
A u to d e s k D o c s
/1 .1
V A
M e m p h is
B ld g
P ri m a ry
C a re
/1 .1
A v
.r v t
/1
/2
:4
:4
P
M
AF102
FIRST FLOOR FLOOR FINISH PLAN
GUIDON DESIGN, INC
1221 N PENNSYLVANIA STEET
INDIANAPOLIS, IN 46202
317.800.6388
JAMES GOODEN
CMTA CONSULTING ENGINEERS, INC
10411 MEETING STREET
PROSPECT, KY 40059
502.326.3085
ANDREW MYERS
RENOVATE BUILDING 1 PRIMARY
CARE
MEMPHIS VAMC
614-17-113
RYAN STEPHENS,
COR MEMPHIS, TN
05/23/2023
BID SET
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"AF102
1 FIRST FLOOR - FLOOR FINISH PLAN
NO SCALEAF102
5 FLOORING LEGEND
REFLECTED CEILING PLAN GENERAL NOTES
REFLECTED CEILING PLAN NOTES
A
B
C
D
E
F
G
H
THE ARCHITECTURAL REFLECTED CEILING PLAN SHALL GOVERN THE LAYOUT
OF ALL CEILING ELEMENTS, HEIGHTS AND/OR PENETRATIONS. COORDINATION
OF THE ARCHITECTURAL AND ENGINEERING ELEMENTS ARE THE
RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS TO VERIFY
FIELD CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT AND
COR.
SHOWN SIZES OF MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT ARE
FOR REFERENCE ONLY. REFER TO ENGINEERING PLANS FOR ADDITIONAL
INFORMATION. COORDINATE SCOPE OF WORK WITH ENGINEERING DRAWINGS.
ACOUSTIC PANEL CEILING SHALL BE CENTERED IN THE ROOM AND INSTALLED
TO ELIMINATE NARROW CUT STRIPS OF PANELS ALONG THE EDGES OF WALLS
AND BULKHEADS. COORDINATE WITH THE LIGHTING LAYOUT. THE LIGHTING
SHALL BE CENTERED IN ROOMS WHERE POSSIBLE OR TO AVOID CONFLICT
WITH PATIENT LIFTS WHERE THEY OCCUR.
CEILING MOUNTED ITEMS (SPRINKLER HEADS, MOUNTING DEVICES, ETC.)
SHALL BE CENTERED IN THE CEILING PANELS UNLESS NOTED OTHERWISE.
ABOVE CEILING WORK REQUIRED BEYOND THE SCOPE OF THE WORK SHALL
BE COORDINATED WITH PATIENT SAFETY, INFECTION CONTROL, AND THE COR.
CEILING TILE REMOVED IN ORDER TO COMPLETE ABOVE CEILING WORK SHALL
BE STORED IN A SAFE DRY LOCATION. DAMAGED OR BROKEN CEILING TILES
SHALL BE REPLACED. DRYWALL CEILINGS SHALL BE PATCHED, PREPPED AND
NEW FINISH APPLIED TO MATCH EXISTING.
REFER TO FINISHES SHEETS AND SPECIFICATIONS FOR INFORMATION ON
GYPSUM BOARD PAINT FINISH.
ALL CEILINGS SHALL BE INSTALLED PER MANUFACTURER'S STANDARD DETAILS
FOR THE SEISMIC CONDITIONS MATCHING THE SITE.
PROVIDE 24" X 24" ACCESS PANEL IN GWB CEILING, CONFIRM LOCATION
WITH COR IN COORDINATION WITH PLACEMENT OF ENGINEERING WORK.
PROVIDE ABOVE CEILING STRUCTURE BRACING FOR CEILING HUNG TOILET
PARTITION.
PROVIDE CUBICLE TRACK AND ABOVE CEILING BRACING.
PROVIDE ACOUSTIC PANEL GRID ASSEMBLY INFILL TO ALIGN WITH EXISTING
CEILING
ALIGN FINISH FACE OF BULKHEAD AND FINISH FACE OF WALL
CONSTRUCTION.
MATCH EXISTING CORRIDOR CEILING HEIGHT.
PROVIDE CEILING MOUNTED BARIATRIC LIFT SYSTEM AND ABOVE CEILING
BRACING.
PROVIDE SINGLE ACOUSTICAL PANEL WITHIN GRID.
NO CEILING. EXPOSED STRUCTURE ABOVE.
KEY PLAN
N
A
TYPE GRAPHIC DESCRIPTION
D
2x2 ACOUSTICAL CEILING TILE (AP1)
GYPSUM BOARD CEILING. CEILING PAINT.
REFLECTED CEILING PLAN TYPE LEGEND
G
A
B
C
D
E
F
H
1 2 3 4 5 6 7 8 9 10 11
PACT TOILET
CW183
STORAGE
CW160G
TELE-HEALTH
CW160B
TELE-RETINAL
CW160A
TEAM WORK AREA
CW160
TELE-HEALTH
CW160D
HYBRID EXAM
CW160E
SOILED
CW161
CLEAN
CW162
HYBRID EXAM
CW186
HYBRID EXAM
CW150S
HYBRID EXAM
CW150R
HYBRID EXAM
CW150Q
WOMEN EXAM
CW150P
WOMEN EXAM
CW150N WOMEN'S TOILET
CW150O
HYBRID EXAM
CW150M
HYBRID EXAM
CW150L
HYBRID EXAM
CW150K
HYBRID EXAM
CW150J
PROCEDURE
CW150H
PROCEDURE TOILET
CW150I
HYBRID EXAM
CW150G
HYBRID EXAM
CW150F
HYBRID EXAM
CW150E HYBRID EXAM
CW150D
HYBRID EXAM
CW140Q
HYBRID EXAM
CW150C
HYBRID EXAM
CW150B HYBRID EXAM
CW150A
NURSE MANAGER
CW152
HAC
CW171
PATIENT CORRIDOR
CWC9
PATIENT CORRIDOR
CWC4
WOMEN EXAM
CW140J
WOMEN TOILET
CW140I
WOMEN EXAM
CW140H
HYBRID EXAM
CW140G
PACT TOILET
CW140U
HYBRID EXAM
CW140F
HYBRID EXAM
CW140E
HYBRID EXAM
CW140D
HYBRID EXAM
CW140C
HYBRID EXAM
CW140B
HYBRID EXAM
CW140A
HT / WT
CWC6-A
HYBRID EXAM
CW140T
HYBRID EXAM
CW140S
HYBRID EXAM
CW140R
HT / WT
CWC4-A
PACT TOILET
CW151
HYBRID EXAM
CW140P
HYBRID EXAM
CW140O
HYBRID EXAM
CW140N
HYBRID EXAM
CW140M
HYBRID EXAM
CW140L
HYBRID EXAM
CW140K
FAMILY TOILET
CW174
PATIENT CORRIDOR
CWC6
TEAM WORK AREA
CW140
TEAM WORK AREA
CW150
STAFF LOCKER
CW157
STAFF FEMALE
TOILET
CW158
STAFF MALE TOILET
CW159
PACT WORKROOM
CW142
PACT WORKROOM
CW143
CLEAN
CW144
STAFF FEMALE
TOILET
CW145
STAFF MALE TOILET
CW146
EQUIPMENT
CW147
SHAFT
SOILED
CW149
PACT WORKROOM
CW148
SHAFT
STAFF LOUNGE /
CONFERENCE /
TRAINING ROOM
CW155
STAIR NO. 3
STAFF CORRIDOR
CWC5
FAMILY TOILET
CW175
HT / WT
CWC9-A
FEMALE PUBLIC
TOILET
CW170B
MALE PUBLIC
TOILET
CW170A
STAIR NO. 1
MEDICATION
CW150T
MEDICATION
95-A
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"A 9' - 0"
A 9' - 0"
A 9' - 0" A 9' - 0"
A 9' - 0" A 9' - 0" A 9' - 0"
A 9' - 0" A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"A 9' - 0"A 9' - 0"
A 8' - 0"
A 9' - 0"A 9' - 0"A 9' - 0"A 9' - 0" A 9' - 0"A 9' - 0"
A 9' - 0" A 9' - 0"
A 9' - 0" A 9' - 0" A 9' - 0"
A 9' - 0"
A 9' - 0" A 9' - 0" A 9' - 0"
A 9' - 0"A 9' - 0"A 9' - 0"A 9' - 0"A 9' - 0"A 9' - 0"A 9' - 0"A 9' - 0"A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 8' - 0"
A 9' - 0"
A 8' - 0"
A 9' - 0"
A 8' - 0"
A 8' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 8' - 6" A 9' - 6" A 8' - 6" A 9' - 6"
A 8' - 6" A 9' - 6" A 8' - 6" A 9' - 6"
A 8' - 6"
2' - 0" TYP.
D 8' - 0"
2' - 0 1/2" TYP.
D 8' - 0"
AS403
Sim4
AS403
Sim
A 8' - 0"
A 8' - 0"
A 9' - 0"A 9' - 0"
A 9' - 0" A 9' - 0"
A 9' - 0"A 9' - 0"
A 9' - 0"
WAITING AREA
CW170
CORRIDOR
CWC1RECEPTION
CW180
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 10' - 0"
HAC
CW187
WHEELCHAIR
CWC1E
CHECK-IN KIOSK
CWC1F
VOLUNTEER
CWC1D
MEDICATION
CW160-A
OFFICE MANAGER
CW153
CHIEF MEDICAL
OFFICER
CW154
SHARED MEDICAL
APPT
CW185
SHARED MEDICAL
APPT
CW184
STORAGE
CW184A
STORAGE
CW185A
PACT TOILET
CW186
DATA
CW169
ENTRANCE
VESTIBULE
CWC1A
TOILET VESTIBULE
CWC15A
CORRIDOR
CWC14
CORRIDOR
CWC13
D 8' - 0" D 8' - 0" D 8' - 0" D 8' - 0"
D 8' - 0" D 8' - 0" D 8' - 0"
D 8' - 0"
A 8' - 0" A 8' - 0"
A 8' - 0"
A 9' - 0"
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
AS403
Sim
P-6
P-6 P-6
P-6P-6
P-6 P-6
P-6P-6
P-6 P-6
P-6
P-6
P-6P-6P-6P-6
P-6
P-6P-6P-6P-6
AS403
Sim
AS403
Sim
AS501
Sim
AS501
Sim
A 9' - 0"
A 9' - 0"
A 9' - 0"
A 8' - 0"
AS403
Sim
3'
/4
8'
ALL SIDES
1' - 6" TYP.
2'
T Y
P
2' - 0" TYP.
1'
2'
T Y
P
D 8' - 0" 1'
33333333
3 3 3 3 3 3 3 3 3
3 3
ELECTRICAL
CW160C
3 3 3 3
3 3 3 3 3 3 3 3
3 3 3
AS403
N
A 9' - 0"
A 9' - 0"
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
Building Number
JLG DMC
A u to d e s k D o c s
/1 .1
V A
M e m p h is
B ld g
P ri m a ry
C a re
/1 .1
A v
.r v t
/1
/2
:4
:5
P
M
AS111
FIRST FLOOR REFLECTED
CEILING PLANGUIDON DESIGN, INC
1221 N PENNSYLVANIA STEET
INDIANAPOLIS, IN 46202
317.800.6388
JAMES GOODEN
CMTA CONSULTING ENGINEERS, INC
10411 MEETING STREET
PROSPECT, KY 40059
502.326.3085
ANDREW MYERS
RENOVATE BUILDING 1 PRIMARY
CARE
MEMPHIS VAMC
614-17-113
RYAN STEPHENS,
COR MEMPHIS, TN
05/23/2023
BID SET
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"AS111
1 FIRST FLOOR - REFLECTED CEILING PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
V P r o j e c t s V
T C
L
R e v i t
V
A M e m p h i s B l d g C l i n i c L a b r v t
A
M
GUIDON DESIGN, INC
905 N CAPITOL AVE, SUITE 100
INDIANAPOLIS, IN 46204
TEL: 317.800.6388
ANDREW SCHAEWE
CMTA CONSULTING ENGINEERS, INC
10411 MEETING STREET
PROSPECT, KY 40059
ANDREW MYERS
RENOVATE PRIMARY
CARE
MEMPHIS VAMC
614-17-113
RYAN STEPHENS, COR
MEMPHIS, TN 05/01/2019
BID SET
FULLY SPRINKLERED
TEL: 502.326.3085
Revisions: Date: AJM MJH
FX101
FIRE PROTECTION NOTES &
DETAILS
AutoCAD SHX Text FIRE PROTECTION DESIGN NOTES: 1. THE ENTIRE BUILDING IS TO BE 100% COVERED WITH A WET FIRE PROTECTION SYSTEM THE ENTIRE BUILDING IS TO BE 100% COVERED WITH A WET FIRE PROTECTION SYSTEM DESIGNED IN ACCORDANCE WITH NFPA 13 AND NFPA 14. SPRINKLER DENSITIES SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 13. THE EXISTING WET FIRE PROTECTION SYSTEM IS TO BE MODIFIED FOR THE NEW ROOM AND CEILING LAYOUTS. REMOVE ALL EXISTING PIPING AND HEADS COMPLETELY AND INSTALL NEW AFTER THE MECHANICAL DUCTWORK AND PIPING HAS BEEN REINSTALLED. PROVIDE ALL NEW SPRINKLER PIPING AND HEADS. 2. THE SUCCESSFUL FIRE PROTECTION CONTRACTOR SHALL OBTAIN AND UTILIZE THE THE SUCCESSFUL FIRE PROTECTION CONTRACTOR SHALL OBTAIN AND UTILIZE THE ARCHITECTURAL REFLECTED CEILING PLAN FOR LAYING OUT THE SPRINKLER HEADS. THE REFLECTED CEILING PLANS SHOWN ARE TO COORDINATE CEILING TYPES AND LOCATIONS, REFER TO THE MECHANICAL AND ELECTRICAL DRAWINGS FOR CEILING DEVICE LOCATIONS. REFER TO SPECIFICATIONS FOR COORDINATION DRAWING REQUIREMENTS. 3. ALL AREAS SHALL BE SPRINKLED WITH A WET FIRE PROTECTION SYSTEM FED FROM A ALL AREAS SHALL BE SPRINKLED WITH A WET FIRE PROTECTION SYSTEM FED FROM A RETURN BEND ARRANGEMENT. SPRINKLERS SHALL BE FM APPROVED. UTILIZE QUICK RESPONSE HEADS WHERE ABLE. USE THE FOLLOWING HEADS IN SPECIFIC AREAS AS INDICATED BELOW. REFER TO SPECIFICATIONS FOR DIFFERENT TYPES OF SPRINKLERS. IN AREAS WITH CEILINGS USE RECESSED SPRINKLERS. ALL SPRINKLERS SHALL BE CENTERED IN BOTH DIRECTIONS OF A LAY-IN CEILING TILE. IN AREAS CONSIDERED CLEAN ROOMS (SPACES NEEDING TO BE WASHED DOWN), USE CONCEALED SPRINKLERS. PROVIDE COVER-PLATE TO MATCH THE CEILING COLOR. FOR AREAS UTILIZING CONCEALED SPRINKLERS, ALL SPRINKLERS WITHIN THE COMPARTMENT MUST BE COORDINATED TO STANDARD RESPONSE. IN AREAS WITHOUT CEILING USE UPRIGHT AND/OR WALL MOUNTED SPRINKLER HEADS. IN AREAS AS NOTED USE UL LISTED OR FM APPROVED "INSTITUTIONAL" TYPE QR SPRINKLER HEADS IN ALL PSYCHIATRIC AREAS. PROVIDE AND INSTALL PER VA STANDARDS (PG-18-14). 4. HVAC DUCTWORK MAINS SHALL BE INSTALLED PRIOR TO FIRE PROTECTION PIPING. PROVIDE HVAC DUCTWORK MAINS SHALL BE INSTALLED PRIOR TO FIRE PROTECTION PIPING. PROVIDE DRAIN VALVES IN THE FIRE PROTECTION SYSTEM WHERE NECESSARY TO COMPLETELY DRAIN THE SYSTEM. ALL EXISTING PIPING IS TO BE REMOVED AS REQUIRED TO INSTALL NEW MAINS. 5. THE ASSOCIATED TRADES SHALL COORDINATE THE INSTALLATION OF EQUIPMENT, SUCH AS THE ASSOCIATED TRADES SHALL COORDINATE THE INSTALLATION OF EQUIPMENT, SUCH AS LIGHTING AND CEILING DIFFUSERS SO THAT THERE IS NO INTERFERENCE WITH THE OPERATION AND MAINTENANCE OF THE SPRINKLER HEADS, TAMPER, AND FLOW SWITCHES. 6. INSTALL ALL PIPING AT LEAST 12" ABOVE FINISHED CEILING ELEVATION TO ALLOW FOR INSTALL ALL PIPING AT LEAST 12" ABOVE FINISHED CEILING ELEVATION TO ALLOW FOR SUITABLE ACCESS TO ABOVE CEILING. 7. RUN NO SPRINKLER MAINS/BRANCH PIPES OVER LIGHT FIXTURES OR WITHIN 12" OF RUN NO SPRINKLER MAINS/BRANCH PIPES OVER LIGHT FIXTURES OR WITHIN 12" OF SURFACE MOUNTED LIGHT FIXTURES. 8. ALL PIPING SHALL BE INSTALLED AS HIGH AS POSSIBLE. LOW PIPING WILL HAVE TO BE ALL PIPING SHALL BE INSTALLED AS HIGH AS POSSIBLE. LOW PIPING WILL HAVE TO BE RELOCATED, BY THE CONTRACTOR, IF IT COULD HAVE BEEN INSTALLED HIGHER. THIS WILL BE UP TO THE DISCRETION OF THE ENGINEER. 9. PROVIDE ALL REQUIRED DRAIN PIPING TO TEST FLOW SWITCHES. DISCHARGE DRAIN PIPING TO PROVIDE ALL REQUIRED DRAIN PIPING TO TEST FLOW SWITCHES. DISCHARGE DRAIN PIPING TO OUTDOORS OR A FLOOR DRAIN. 10. NO PIPING IS TO BE ROUTED ABOVE ELECTRICAL PANELS, TRANSFORMERS, COMPUTER RACKS, NO PIPING IS TO BE ROUTED ABOVE ELECTRICAL PANELS, TRANSFORMERS, COMPUTER RACKS, ETC. AS REQUIRED BY THE ELECTRICAL CODE. FIELD VERIFY ALL EXISTING ELECTRICAL LOCATIONS PRIOR TO DESIGNING THE FIRE PROTECTION PLANS. 11. THE SUCCESSFUL FIRE PROTECTION CONTRACTOR WILL BE REQUIRED TO OBTAIN A NEW FLOW THE SUCCESSFUL FIRE PROTECTION CONTRACTOR WILL BE REQUIRED TO OBTAIN A NEW FLOW TEST PRIOR TO STARTING CALCULATIONS. SIZE ALL FIRE PROTECTION PIPING IN ACCORDANCE WITH NFPA 13 AND 14 AND PROVIDE A 10% SAFETY FACTOR. PIPE SIZING SHALL BE ACCOMPLISHED USING HYDRAULIC CALCULATIONS. SUBMIT HYDRAULIC CALCULATIONS AND SYSTEMS DESIGN FOR REVIEW TO: THE M/E ENGINEER. USE 250 GPM FOR THE SPRINKLER HOSE STREAM CALCULATION. THIS BUILDING IS SUPPLIED WITH A FIRE PUMP, IF LATEST ANNUAL FIRE PUMP TEST IS LESS THAN A YEAR OLD, THAT INFORMATION, LESS THE PUMP BOOST, SHALL BE UTILIZED IN THE PREPARATION OF THE CONTRACTOR SPRINKLER SHOP DRAWINGS. (VA FPDM PARAGRAPH 6.1D) 12. ZONING OF THE FIRE SUPPRESSION SYSTEM SHALL MEET ALL APPLICABLE CODES AND ZONING OF THE FIRE SUPPRESSION SYSTEM SHALL MEET ALL APPLICABLE CODES AND STANDARDS. ALL FIRE PROTECTION CONTROL VALVES SHALL BE EQUIPPED WITH LISTED VALVE SUPERVISORY SWITCHES AND INTERCONNECTED WITH THE BUILDING FIRE ALARM SYSTEM. COORDINATE ALL FLOW & TAMPER SWITCHES WITH THE ELECTRICAL CONTRACTOR TO PROVIDE ALL NECESSARY CONNECTIONS. 13. PROVIDE SEISMIC BRACING FOR ALL FIRE PROTECTION PIPING IN ACCORDANCE WITH PROVIDE SEISMIC BRACING FOR ALL FIRE PROTECTION PIPING IN ACCORDANCE WITH APPLICABLE STANDARDS. 14. WHEN THE SCOPE OF WORK AFFECTS A PORTION OF A COMPARTMENT, THE CONTRACTOR WHEN THE SCOPE OF WORK AFFECTS A PORTION OF A COMPARTMENT, THE CONTRACTOR SHALL PROVIDE NEW SPRINKLERS THAT MATCH THE RATING AND TYPE IN THE COMPARTMENT. WHERE THIS IS NOT FEASIBLE OR PERMITTED BY CODE, THE CONTRACTOR SHALL PROVIDE SPRINKLERS FOR THE ENTIRE COMPARTMENT WHERE REQUIRED REGARDLESS OF PROJECT LIMITS. ANY EXISTING SPRINKLERS IN THE COMPARTMENT NOT MATCHING THE FINISH OF THE NEW SPRINKLERS SHALL ALSO BE REPLACED. 15. PROVIDE SPRINKLERS WITH GUARDS IN MECHANICAL AND ELECTRICAL SPACES AND UNDER PROVIDE SPRINKLERS WITH GUARDS IN MECHANICAL AND ELECTRICAL SPACES AND UNDER ANY OBSTRUCTIONS LOWER THAN EIGHT FEET REQUIRING PROTECTION. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING ALL TEMPORARY CONNECTIONS TO CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING ALL TEMPORARY CONNECTIONS TO ENSURE THAT THE EXISTING SPRINKLER SYSTEM OUTSIDE THE SCOPE OF WORK REMAINS ACTIVE AT ALL TIMES. EXISTING FIRE SPRINKLER ZONES SHALL BE MAINTAINED.
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NOTE: 1.
AutoCAD SHX Text APPLICABLE TO PENETRATIONS OF ALL FIRE RATED MEMBRANES, IN ACCORDANCE WITH NFPA 101. REFER TO SPECIFICATIONS SECTION 07 84 00, FIRE STOPPING SYSTEMS.
AutoCAD SHX Text
INSULATED PIPE OR DUCT
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
FIRESTOP MATERIAL
AutoCAD SHX Text 3/4" [19mm] APPROVED FIRESTOP INSULATION WITH VAPOR BARRIER
AutoCAD SHX Text
PIPE SLEEVE WHERE SPECIFIED
AutoCAD SHX Text 1/4" [6.4mm] ANCHORROD FOR NEW CONSTRUCTION
AutoCAD SHX Text
WELD
AutoCAD SHX Text [25mm]
AutoCAD SHX Text [150mm]
AutoCAD SHX Text [150mm]
AutoCAD SHX Text
FLOOR OR DECK PENETRATION
AutoCAD SHX Text
PARTITION OR CHASE PENETRATION
AutoCAD SHX Text [150mm]
AutoCAD SHX Text [150mm]
AutoCAD SHX Text
MASONRY PARTITION
AutoCAD SHX Text
PARTITION SUPPORT
AutoCAD SHX Text
FIRESTOP MATERIAL
AutoCAD SHX Text [150mm]
AutoCAD SHX Text [150mm]
AutoCAD SHX Text 3/4" [19mm] APPROVED FIRESTOP INSULATION WITH VAPOR BARRIER
AutoCAD SHX Text
DRYWALL PARTITION
AutoCAD SHX Text
INSULATED PIPE OR DUCT
AutoCAD SHX Text
DUCT/PIPE PENETRATION OF SMOKE/FIRE BARRIERS
AutoCAD SHX Text
FIRE MAIN
AutoCAD SHX Text
%%URETURN BEND DETAIL
AutoCAD SHX Text
NTS
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
SPRINKLER PIPE
AutoCAD SHX Text
FLEXIBLE RETURN BEND
AutoCAD SHX Text
MAY BE PROVIDE AS AN
AutoCAD SHX Text
RECESSED PENDANT SPRINKLER
AutoCAD SHX Text
NOTE: SIMILAR FOR TYCO "RAVEN" SPRINKLER
AutoCAD SHX Text
EQUAL.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ADDENDUM 1
AutoCAD SHX Text 9-20-2022
AutoCAD SHX Text
ALL SIDES
G
A
B
C
D
E
F
H
1 2 3 4 5 6 7 8 9 10 11
PACT TOILET
STORAGE
TELE-HEALTH
TELE-RETINAL
TEAM WORK AREA
TELE-HEALTH
HYBRID EXAM
CLEAN
SOILED
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
WOMEN EXAM
WOMEN EXAM
WOMEN'S TOILET
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
PROCEDURE
PROCEDURE TOILET
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
NURSE MANAGER
HAC
PATIENT CORRIDOR
PATIENT CORRIDOR
WOMEN EXAM
WOMEN TOILET
WOMEN EXAM
HYBRID EXAM
PACT TOILET
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HT / WT
15-A
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HT / WT
27-A
PACT TOILET
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
HYBRID EXAM
FAMILY TOILET
PATIENT CORRIDOR
TEAM WORK AREA
TEAM WORK AREA
STAFF LOCKER
STAFF FEMALE
TOILET
STAFF MALE TOILET
PACT WORKROOM
PACT WORKROOM
CLEAN
STAFF FEMALE
TOILET
STAFF MALE TOILET
EQUIPMENT
SHAFT
SOILED
PACT WORKROOM
SHAFT
STAFF LOUNGE /
CONFERENCE /
TRAINING ROOM
STAIR NO. 3
STAFF CORRIDOR
FAMILY TOILET
HT / WT
49-A
FEMALE PUBLIC
TOILET
MALE PUBLIC
TOILET
STAIR NO. 1
MEDICATION
81-A
MEDICATION
95-A
WHEELCHAIR
2-B
CHECK-IN KIOSK
2-C
VOLUNTEER
2-A
MEDICATION
74-A
WAITING AREA
RECEPTION
CORRIDOR
HAC
OFFICE MANAGER
CHIEF MEDICAL
OFFICER
SHARED MEDICAL
APPT
SHARED MEDICAL
APPT
STORAGE
STORAGE
PACT TOILET
DATA
ENTRANCE
VESTIBULE
TOILET VESTIBULE
CORRIDOR
CORRIDOR
ELECTRICAL
ELECTRICAL
EDUCATION
2-D
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
V P r o j e c t s V
T C
L
R e v i t
V
A M e m p h i s B l d g C l i n i c L a b r v t
A
M
GUIDON DESIGN, INC
905 N CAPITOL AVE, SUITE 100
INDIANAPOLIS, IN 46204
TEL: 317.800.6388
ANDREW SCHAEWE
CMTA CONSULTING ENGINEERS, INC
10411 MEETING STREET
PROSPECT, KY 40059
ANDREW MYERS
RENOVATE PRIMARY
CARE
MEMPHIS VAMC
614-17-113
RYAN STEPHENS, COR
MEMPHIS, TN 05/01/2019
BID SET
FULLY SPRINKLERED
TEL: 502.326.3085
Revisions: Date: AJM MJH
FX102
FIRST FLOOR - FIRE
PROTECTION PLAN
SCALE: 1/8" = 1'-0"FX102
1 FIRST FLOOR - FIRE PROTECTION PLAN
N
NO SCALE
KEY PLAN
AutoCAD SHX Text DASHED LINE INDICATES EXISTING AREA WHERE EXISTING SPRINKLER SYSTEM SHALL BE COMPLETELY REMOVED AND REPLACED WITH A NEW FULLY AUTOMATIC SPRINKLER SYSTEM. ALL SPRINKLER RELATED WORK SHALL BE PROVIDED IN ACCORDANCE WITH ALL APPLICABLE NFPA, VA STANDARDS, STATE, AND LOCAL CODES. EXISTING SPRINKLERS SHALL NOT BE RE-USED. REFER TO ELECTRICAL DRAWINGS TO PROVIDE TEMPORARY HEAT DETECTORS DURING CONSTRUCTION.
AutoCAD SHX Text
EXISTING FIRE RISER
AutoCAD SHX Text
EXISTING FIRE RISER
AutoCAD SHX Text
AutoCAD SHX Text
FCA
AutoCAD SHX Text
FCA
AutoCAD SHX Text
4" EXISTING FIRE RISER
AutoCAD SHX Text
4" EXISTING FIRE RISER
AutoCAD SHX Text
2" EXISTING FIRE RISER
AutoCAD SHX Text
2-1/2" EXISTING FIRE RISER
AutoCAD SHX Text
6" EXISTING FIRE RISER
AutoCAD SHX Text
3-1/2" EXISTING FIRE RISER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text DASHED LINE INDICATES EXISTING AREA WHERE EXISTING SPRINKLER SYSTEM SHALL BE COMPLETELY REMOVED AND REPLACED WITH A NEW FULLY AUTOMATIC SPRINKLER SYSTEM. ALL SPRINKLER RELATED WORK SHALL BE PROVIDED IN ACCORDANCE WITH ALL APPLICABLE NFPA, VA STANDARDS, STATE, AND LOCAL CODES. EXISTING SPRINKLERS SHALL NOT BE RE-USED. REFER TO ELECTRICAL DRAWINGS TO PROVIDE TEMPORARY HEAT DETECTORS DURING CONSTRUCTION.
AutoCAD SHX Text
%%UPLUMBING TAGGED NOTES:
AutoCAD SHX Text
XX
AutoCAD SHX Text
1. OFFSET EXISTING FIRE RISER FROM THE FLOOR BELOW TO ACCOMMODATE NEW OFFSET EXISTING FIRE RISER FROM THE FLOOR BELOW TO ACCOMMODATE NEW ARCHITECTURAL LAYOUT. 2. CONNECT NEW RISER PIPING TO EXISTING RISER LOCATION UP TO THE FLOOR CONNECT NEW RISER PIPING TO EXISTING RISER LOCATION UP TO THE FLOOR ABOVE. 3. CONCEAL EXISTING SPRINKLER RISER IN ARCHITECTURAL CHASE. CONCEAL EXISTING SPRINKLER RISER IN ARCHITECTURAL CHASE. 4. PROVIDE NEW FLOOR CONTROL VALVE ASSEMBLY (FCA) WITH SUPERVISED PROVIDE NEW FLOOR CONTROL VALVE ASSEMBLY (FCA) WITH SUPERVISED ISOLATION, CHECK VALVE, FLOW SWITCH, TEST DRAIN TO SERVE RENOVATION AREA. RELOCATE AND RECONNECT ANY TEST DRAIN PIPING RISER. 5. SPRINKLER MAIN OUT TO THE RENOVATION AREA. SPRINKLER MAIN OUT TO THE RENOVATION AREA. 6. RELOCATE HOSE VALVE CABINET TO LOCATION COORDINATED WITH NEW RELOCATE HOSE VALVE CABINET TO LOCATION COORDINATED WITH NEW ARCHITECTURAL WALL. 7. MAINTAIN EXISTING FLOOR CONTROL VALVE ASSEMBLY ZONING FOR THE MAINTAIN EXISTING FLOOR CONTROL VALVE ASSEMBLY ZONING FOR THE SPRINKLERS OUTSIDE OF THE WORK AREA THAT ARE CURRENTLY CONNECTED TO THIS ZONE. RELOCATE ANY TEST DRAIN PIPING TO ARCHITECTURAL CHASE. 8. MAINTAIN CURRENT ZONING FOR SPRINKLERS OUTSIDE OF THE WORK AREA. MAINTAIN CURRENT ZONING FOR SPRINKLERS OUTSIDE OF THE WORK AREA. MODIFY SPRINKLER PIPING AND LAYOUTS AS REQUIRED TO ACCOMMODATE NEW ARCHITECTURAL LAYOUT. IF SPRINKLERS ARE CURRENTLY FED FROM THE RISER UTILIZED FOR THE NEW FLOOR CONTROL VALVE, THEN SPRINKLERS SHALL CONTINUE TO BE SERVED FROM THIS RISER.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ADDENDUM 1
AutoCAD SHX Text 9-20-2022
AutoCAD SHX Text
| 17.1055_RevisedSheets_08.12.2026_Add 2r |
| Sheets |
| AD101 - FIRST FLOOR DEMOLITION PLAN |
| AD401 - ENLARGED DEMOLITION PLAN |
| AF101 - FIRST FLOOR WALL FINISH PLAN |
| AF102 - FIRST FLOOR FLOOR FINISH PLAN |
| AS111 - FIRST FLOOR REFLECTED CEILING PLAN |
| VTPC17-FX101 ADD 1 |
| Sheets and Views |
| VTPC17-FX101-FX101 |
| VTPC17-FX102 ADD 1 |
| Sheets and Views |
| VTPC17-FX102-FX102 |