131_E205.pdf

PDF 544 KB Posted

Attached to
Y1LZ--Project 621-332- Expand Parking Garage & Add OH Walkway
Solicitation number
36C24921R0057
Issued by

About this file

This presolicitation notice is for construction services for Project 621-332 to expand an existing parking garage and add an overhead walkway at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. The project is estimated to cost between $5 million and $10 million. The work includes adding two new levels to the parking garage and constructing an overhead walkway in accordance with provided specifications and drawings. The solicitation is anticipated for release on or by January 15, 2021 and will utilize the LPTA source selection process. Responses are due for an SDVOSB set-aside requirement in accordance with FAR Part 15 and NAICS code 236220. Only SDVOSBs verified in the CVE database and registered in SAM will be considered. The awarded contractor must submit VETS-4212 enrollment evidence. Questions must be submitted in writing to the contracting officer by the specified date.

View the file

Other files

File Type Posted
S02 - CALCULATION OF SELF PERFORMED WORK.pdf PDF
010000 General Requirements revised 02252021.pdf PDF
082_S212.pdf PDF
Price Proposal Template.xlsx XLSX spreadsheet
076_S105.pdf PDF
083_S220.pdf PDF
078_S107.pdf PDF
072_S101.pdf PDF
075_S104.pdf PDF
093013 added.pdf PDF
002_G002_revised_02252021.pdf PDF
095423 added.pdf PDF
Signature Sheet PN 621-332 Parking Garage Site Visit 1-25-2021.pdf PDF
080_S210.pdf PDF
General Conditions Breakout.xlsx XLSX spreadsheet
081_S211.pdf PDF
079_S108.pdf PDF
074_S103.pdf PDF
36C24921R0057 0004.pdf PDF
073_S102.pdf PDF
36C24921R0057 0003.pdf PDF
36C24921R0057 0002.pdf PDF
36C24921R0057 0001.pdf PDF
064_AG102.pdf PDF
093_S511.pdf PDF
052_A410.pdf PDF
Final Reissue CD Specifications Vol I.pdf PDF
137_E302.pdf PDF
Final Reissue 04 - S2 CD Drawings.pdf PDF
029_L101.pdf PDF
063_AG101.pdf PDF
Final Reissue CD Specifications Vol II.pdf PDF
118_F204.pdf PDF
126_E200.pdf PDF
005_G102.pdf PDF
107_P202.pdf PDF
042_A110.pdf PDF
014_C200.pdf PDF
004_G101.pdf PDF
035_A106.pdf PDF
132_E211.pdf PDF
039_A107.pdf PDF
034_A105.pdf PDF
049_A301.pdf PDF
044_A202.pdf PDF
017_C220.pdf PDF
136_E301.pdf PDF
006_G103.pdf PDF
043_A201.pdf PDF
112_P700.pdf PDF
Show 40 more

Latest 50 of 174 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S T

A I R

N

O

S T

A I R

N

O

ELEVATOR NO. 2

ELEVATOR/STAIR NO. 4

RAMP

DOWN

ELECTRICAL LIGHTING, POWER &

SYSTEMS PLAN - GARAGE FIFTH

LEVEL

E205

APPROVED FOR CONSTRUCTION

FINAL CONSTRUCTION DRAWINGS

ARCHITECT/ENGINEERS: CONSULTANTS:

CONSULTANTS

WALKERDesign, Inc.

REISSUED

SHEET NOTES

SHEET KEYNOTES

ISOMETRIC

N

ELECTRICAL LIGHTING, POWER AND SYSTEMS PLAN - GARAGE FIFTH LEVEL

OF 143131PAGE

AutoCAD SHX Text 1.3

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 11.7

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text C.7

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 8.2

AutoCAD SHX Text A

AutoCAD SHX Text

UNCOVERED PARKING AREA BELOW (SEE 4TH LEVEL)

AutoCAD SHX Text P1

AutoCAD SHX Text P2

AutoCAD SHX Text

SEE SHEET E211 FOR ENLARGED STAIR 1 PLAN

AutoCAD SHX Text

EXP JT

AutoCAD SHX Text

WP

AutoCAD SHX Text

WP

AutoCAD SHX Text

WP

AutoCAD SHX Text

WP

AutoCAD SHX Text

WP

AutoCAD SHX Text

N1-TL

AutoCAD SHX Text

N1-TL

AutoCAD SHX Text

N1-TL

AutoCAD SHX Text

N1-TL

AutoCAD SHX Text

N1-TL

AutoCAD SHX Text

N1-TL

AutoCAD SHX Text

N1-TL

AutoCAD SHX Text

N1-TL

AutoCAD SHX Text D

AutoCAD SHX Text

SEE SHEET E211 FOR ENLARGED ELEVATOR 2 (P1 & P2) PLAN

AutoCAD SHX Text

RELOCATED TYPE D FIXTURE (TYP., UNO)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SEE SHEET E211 FOR ENLARGED STAIR 3 PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

UNCOVERED PARKING AREA BELOW (SEE 4TH LEVEL)

AutoCAD SHX Text

SNOW GATE

AutoCAD SHX Text REFER TO ARCH. PLANS FOR LOCATIONS OF GUARD RAILS AROUND PERIMETER; BOND AND GROUND PER DETAILS (TYP.)

AutoCAD SHX Text SEE SHEET E211 FOR ENLARGED ELEVATOR/STAIR 4 ROOF PLANS (DEDUCTIVE ALTERNATE NO. 2 & 3)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text j

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A. SEE SHEET E001 FOR ADDITIONAL SEE SHEET E001 FOR ADDITIONAL GENERAL NOTES. B. ENSURE HINGED LIGHT POLES DO NOT ENSURE HINGED LIGHT POLES DO NOT INTERFERE/CONFLICT WITH GUARDRAILS. C. BOND LIGHTPOLES AND GUARDRAILS TO BOND LIGHTPOLES AND GUARDRAILS TO LIGHTNING PROTECTION DOWN CONDUCTORS.

AutoCAD SHX Text

1. TO CONTROL PANEL TLCP VIA EXISTING TO CONTROL PANEL TLCP VIA EXISTING JUNCTION BOX ON SECOND FLOOR. 2. ORIENT THE POLE SUCH THAT THE ORIENT THE POLE SUCH THAT THE HINGE MECHANISM IS OPERABLE FROM THE GARAGE DECK. ALSO ENSURE THAT THE FIXTURE MAY BE SERVICED FROM THE GARAGE DECK WHEN THE POLE IS LOWERED. 3. CONNECT LIGHT POLE TO GROUND CONNECT LIGHT POLE TO GROUND SYSTEM AND EXISTING CIRCUIT VIA EXISTING JUNCTION BOX ON SECOND LEVEL. 4. SEE DETAILS. CONDUITS FOR LIGHT SEE DETAILS. CONDUITS FOR LIGHT POLE (GROUNDING CONDUIT AND POWER CONDUIT) SHALL BOTH BE CAST IN CONCRETE. COORDINATE WITH PRECASTER. SURFACE MOUNTED CONDUIT AT BASE OF POLE IS NOT ACCEPTABLE. 5. BOND GUARDRAIL TO DOWN CONDUCTOR. BOND GUARDRAIL TO DOWN CONDUCTOR. 6. FROM RECEPTACLE CIRCUIT BELOW.FROM RECEPTACLE CIRCUIT BELOW.

AutoCAD SHX Text one-quarter inch = one foot

AutoCAD SHX Text Revisions

AutoCAD SHX Text Date

AutoCAD SHX Text one-eighth inch = one foot

AutoCAD SHX Text

VA FORM 08-6231, DEC 1989

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text three-eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one-half inch = one foot

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one and one-half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text three-quarters inch = one foot

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Approved: Chief, Engineering Service

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C.O.T.R.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Engineering Planning & Analysis

AutoCAD SHX Text Engineering Health & Safety

AutoCAD SHX Text Engineering Operation Foreman

AutoCAD SHX Text Engineering Bldg. Maint. Foreman

AutoCAD SHX Text Asst. Chief, Engineering Service

AutoCAD SHX Text Approved:

AutoCAD SHX Text Approved: Service Chief

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VAMC MOUNTAIN HOME, TENNESSEE

AutoCAD SHX Text Location

AutoCAD SHX Text Project Title

AutoCAD SHX Text Building Number

AutoCAD SHX Text Checked

AutoCAD SHX Text

ADD OVERHEAD WALKWAY

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text Drawn

AutoCAD SHX Text Date

AutoCAD SHX Text 621-332

AutoCAD SHX Text

AUGUST 10, 2020

AutoCAD SHX Text Department of

AutoCAD SHX Text Veterans Affairs

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text Dwg. File

AutoCAD SHX Text

EXPAND PARKING GARAGE &

AutoCAD SHX Text

AutoCAD SHX Text 4904 Eisenhower Blvd Suite 150 Tampa, FL 33634 PH: (813) 888-5800 FAX: (813) 502-5726 BE-0003840 www.walkerconsultants.com

AutoCAD SHX Text

PH: (850) 433-3023

AutoCAD SHX Text

FAX: (850) 433-3025

AutoCAD SHX Text

FRANK DAUGHTRY

AutoCAD SHX Text a r c h i t e c t

AutoCAD SHX Text Pensacola, FL 32502

AutoCAD SHX Text email: frank@frankda.com

AutoCAD SHX Text 200 E. Government Street

AutoCAD SHX Text Suite 240-A

AutoCAD SHX Text Project No.

AutoCAD SHX Text CONTRACT No. 36C249-19-C-0168

AutoCAD SHX Text P.O. No. 621Z90002

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

AKEA DESIGN, INC.

AutoCAD SHX Text

RANDALL A. HENSLEY, P.E. FLORIDA P.E. NO. 37944

AutoCAD SHX Text 3603 NW 98TH ST., SUITE B GAINESVILLE, FLORIDA 32606 PH: (352) 474-6124 FAX: (352) 553-4437 CERT OF AUTH: FL #29758 AKEA Design Project No. AD177-19

AutoCAD SHX Text This item has been electronically signed and sealed by the individual named at right. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.

AutoCAD SHX Text

FINAL CONSTRUCTION DOCUMENTS

AutoCAD SHX Text 07/20/20

AutoCAD SHX Text ADDENDUM: REISSUE FINAL CDs

AutoCAD SHX Text 08/10/20

AutoCAD SHX Text

TOP LEVEL

AutoCAD SHX Text

GROUND LEVEL

AutoCAD SHX Text

2ND LEVEL

AutoCAD SHX Text

3RD LEVEL

AutoCAD SHX Text

4TH LEVEL

AutoCAD SHX Text

EL. 0'-0"

AutoCAD SHX Text

EL. 12'-10"

AutoCAD SHX Text

EL. 25'-1"

AutoCAD SHX Text

EL. 36'-9"

AutoCAD SHX Text

EL. 48'-5"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 1/16" = 1' - 0"

AutoCAD SHX Text

EXISTING LEVELS

AutoCAD SHX Text

NEW LEVELS

2020-08-11T11:30:02-0400
Randall Hensley

File details come from the government source that posted it. Updated .