Attachment 9 - Atlanta VAMC Crawl Space ACM Survey Report.pdf

PDF 6 MB Posted

Attached to
508-26-152 | Bus Duct Replacement
Solicitation number
36C24726R0058
Issued by

About this file

This is a Pre-Renovation Asbestos-Containing Material (ACM) Survey Report for the Joseph Maxwell Cleland Atlanta Veterans Administration Medical Center located at 1670 Clairmont Drive in Decatur, Georgia. The survey was conducted on January 29-30 and February 4-7, 2025, by the Program Support Center, Federal Occupational Health (U.S. Department of Health and Human Services) and reported on March 21, 2025, under project reference numbers A732710, S2025-0002, and SO 739208.

The survey examined approximately 230,000 square feet of crawl space beneath Buildings A, B, and C to identify asbestos-containing materials prior to renovation. The scope included visual inspection and bulk/soil sampling analyzed using PLM method EPA/600/R93/116 for building materials and CARB 435 for soil samples. The survey identified asbestos in multiple materials: Building B (accessible via mechanical rooms GC 347 and GC 346) contained pipe fitting insulation with 2% Amosite and soil with 0.5-3.8% Amosite across approximately 36,500 square feet. Building C contained mastic on fiberglass piping insulation (2% Chrysotile), canvas-wrapped piping insulation (40% Chrysotile), transite-type flue (15% Chrysotile), and pipe fitting insulation (3% Amosite). All identified materials are classified as Class I asbestos work under OSHA requirements and regulated asbestos-containing material (RACM) under NESHAP. The survey recommends development of an asbestos abatement design based on these findings. Supporting documentation includes laboratory analysis reports from Scientific Analytical Institute (NVLAP accredited), staff credentials showing EPA AHERA certification and confined space entry permits, photographic documentation of identified ACM locations, and sample location maps for each building section.

View the file

Other files

File Type Posted
RFI Responses Round 2 508-26-152.docx DOCX document
2nd Site Visit Attendance Sheet 508-26-152.docx DOCX document
36C24726R0058 0002.docx DOCX document
36C24726R0058 0001.docx DOCX document
Attachment 8 - Site walkthrough attendance sheet.pdf PDF
Attachment 5 - External Bus Duct pictures.docx DOCX document
Attachment 2 - Chapter 1.9 Confined Space Entry Attachment A.docx DOCX document
Attachment 7 - Internal Duct Illustration drawing.jpg JPG image
Attachment 1 - Atlanta VAMC PRCS SOP_JUL2024.pdf PDF
Attachment 3 - Crawl Space Asbestos Compliance Program_SEP2025.pdf PDF
Attachment 4 - Detailed Safety Requirements.docx DOCX document
Attachment 6 - Internal Bus Duct pictures.docx DOCX document
Attachment 11 - Specs.pdf PDF
Attachment 4 - Itemized Cost Breakdown.xlsx XLSX spreadsheet
Attachment 3 - Past Performance Questionnaire -PPQ.pdf PDF
Attachment 10 - As-Builts full - Raceways details.pdf PDF
Attachment 5 - DBA Wage Determination GA20260305 01-23-2026.pdf PDF
Attachment 1 - Experience Modification Rate Form.pdf PDF
Attachment 8 - Drawing - Normal Power Riser Diagram Phase E.pdf PDF
Attachment 6 - INVOICING.pdf PDF
Attachment 9 - Drawing - ESU CD 12-10-2007.pdf PDF
36C24726R0058.docx DOCX document
Attachment 7 - Drawing - Normal Power Riser Diagram Phase D.pdf PDF
Attachment 2 - VAAR 852.219-75 VA Notice of Limitations on Subcontracting Jan 2023 Deviation.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pre-Renovation Asbestos-Containing Material (ACM) Survey (Inspection and Testing)

Survey Location:

Joseph Maxwell Cleland Atlanta VAMC Department of Veterans Affairs Crawl Space located beneath Buildings A, B, and C 1670 Clairmont Drive Decatur, GA 30033

Survey Date: January 29 & 30 and February 4 & 7, 2025 Report Date: March 21, 2025

Project Reference Numbers: A732710, S2025-0002, SO 739208

Prepared by:

Program Support Center, Federal Occupational Health U.S. Department of Health and Human Services Everett McKinley Dirksen Federal Building (Z1R) 219 South Dearborn | Room 288 Chicago, IL 60604

Table of Contents

EXECUTIVE SUMMARY

Introduction Scope of Work Building and Location Description Bulk and Soil Sampling Results Summary of Identified Asbestos-Containing Materials Sampling Protocol and Methodology Technical Requirements Findings Summary and Recommendations

Appendices

Appendix A: PLM Laboratory Report, including Chain of Custody Appendix B: Approximate Sample Locations Appendix C: Photographic Documentation Appendix D: Staff and Laboratory Credentials Appendix E: Confined Space Entry Permits

Department of Veterans Affairs Crawl Space ACM Survey

Joseph Maxwell Cleland Atlanta March 21, 2025

EXECUTIVE SUMMARY

A pre-renovation asbestos-containing materials (ACM) survey was conducted on January 29 & 30 and February 4 & 7, 2025, in the crawl spaces located beneath buildings A, B, and C of the Joseph Maxwell Cleland Atlanta Veterans Administration Medical Center (VAMC) located at 1670 Clairmont Drive in Decatur, GA. The purpose of testing was to determine if asbestos-containing materials are located in the building materials and soil in the crawl space below the hospital.

The scope of work consisted of evaluation (visual inspection) and testing in the crawl spaces located beneath buildings A, B, and C and included the following:

1. The crawl space area is an asbestos regulated area (OSHA requirements apply).

2. Collection of bulk samples for asbestos will be analyzed per PLM method EPA/600/R-

93/116 (primarily TSI maybe surfacing materials). Soil samples will be analyzed per PLM method CARB 435.

3. Soil samples throughout the crawl spaces beneath buildings A, B and C (approximately 230,000 sf) will be sectioned off into approximately 5,000 SF grids and sampled accordingly.

4. Provide an assessment report that can be used to develop an asbestos abatement cost estimate.

Survey results and findings observed and/or found during this survey identified asbestos in the following materials and locations:

Crawl Space – Building B (accessible through mechanical room GC 347)

• Pipe Fitting Insulation

• Soil

Crawl Space – Building B (accessible through mechanical room GC 346)

• Pipe Fitting Insulation

• Soil

Crawl Space – Building C

• Mastic on Fiberglass Piping Insulation

• Canvas Wrapped Piping Insulation

• Transite-Type Flue

• Pipe Fitting Insulation

Based on the above findings, an asbestos abatement design is recommended.

Joseph Maxwell Cleland Atlanta March 21, 2025

Personnel at all levels were cooperative and participated in this survey. The report that follows this Executive Summary should be read in its entirety because it includes important information not included in this summary, such as task descriptions, workspace locations, regulatory requirements, and additional recommendations.

Introduction

A representative from the Federal Occupational Health (FOH) conducted a pre-renovation asbestos-containing materials (ACM) survey on January 29 & 30 and February 4 & 7, 2025, in the crawl spaces located beneath buildings A, B, and C of the Joseph Maxwell Cleland Atlanta Veterans Administration Medical Center (VAMC) located at 1670 Clairmont Drive in Decatur, GA. This survey was performed under the Interagency Agreement established between [VAMC-Atlanta] and the U.S. Public Health Service (USPHS) Federal Occupational Health (FOH) and in accordance with a scope of work developed specifically for this project.

Mr. Ricky Garmon, Mrs. Erin Garmon, MPH, CIH, Mr. Chad Reynolds, and Mr. Clint Atkins, contractor, performed this inspection on behalf of FOH and under the direction of Ms. Michelle Stemmons, FOH Program Manager, Environmental Health, and Safety Services. Mr. Rodney Hamm, Industrial Hygienist with the Atlanta VAMC Safety Office provided agency support and assisted in the coordination and completion of this testing.

Scope of Work

The scope of work consisted of evaluation (visual inspection) and testing in the crawl spaces located beneath buildings A, B, and C and included the following:

1. The crawl space area is an asbestos regulated area (OSHA requirements apply).

2. Collection of bulk samples for asbestos will be analyzed per PLM method EPA/600/R-

93/116 (primarily TSI maybe surfacing materials). Soil samples will be analyzed per PLM method CARB 435.

3. Soil samples throughout the crawl spaces beneath buildings A, B and C (approximately 230,000 sf) will be sectioned off into approximately 5,000 SF grids and sampled accordingly.

4. Provide an assessment report that can be used to develop an asbestos abatement cost estimate.

Building and Location Description

The Joseph Maxwell Cleland Atlanta Veterans Administration Hospital is located in Decatur, GA and serves as the main VA hospital in the metro Atlanta Area. The crawl space is located under the entire hospital and is separated into sections A, B, and C, and were each constructed at different times. Each section was accessible from a different location.

Bulk and Soil Sampling Results

Tables 1 – 5 below present suspect asbestos-containing materials identified during the inspection and includes Homogeneous Area (Material) (HA) Number, Suspect Asbestos-Containing Material (ACM), Sample ID, and Asbestos Content (% and type). Materials containing asbestos are indicated in red boldface.

See Appendix A for laboratory report and chain of custody.

Table 1 Suspect Asbestos-Containing Materials

Crawl Space – Building A Atlanta VAMC, Decatur, GA

Collected on 1/30/25

Homogenous Area (Material)

(HA)

Suspect Asbestos- Containing Material

(ACM)

Sample ID

Asbestos Content

(% and type)

HA 1 Gray Duct Mastic

ADM-01 NAD

ADM-02 NAD

HA 2 Fireproofing

AFP-03 NAD

AFP-04 NAD

AFP-05 NAD

AFP-06 NAD

AFP-07 NAD

AFP-08 NAD

AFP-09 NAD

HA 3

Chill Water System Piping

Insulation

ACW-10 NAD

ACW-11 NAD

ACW-12 NAD

HA 4

Steam System

Piping Insulation

AST-13 NAD

AST-14 NAD

AST-15 NAD

HA 5

Steam Condensate Piping

Insulation

ASC-16 NAD

ASC-17 NAD

ASC-18 NAD

HA 6 Domestic Hot Water Piping Insulation

ADHW-19 NAD

ADHW-20 NAD

ADHW-21 NAD

HA 7

Domestic Cold-Water

Piping Insulation

ADCW-22 NAD

ADCW-23 NAD

ADCW-24 NAD

HA 8 Soil

AS-01 NAD

AS-02 NAD

AS-03 NAD

AS-04 NAD

AS-05 NAD

AS-06 NAD

Table 2

Crawl Space – Building B- Access through Mechanical Room GC-347 Atlanta VAMC, Decatur, GA

Collected on 2/7/25

Homogenous Area (Material)

(HA)

Suspect Asbestos- Containing Material

HA 9 Fireproofing

BFP-01 NAD

BFP-02 NAD

BFP-03 NAD

BFP-04 NAD

HA 10 Duct Mastic

BDM-05 NAD

BDM-06 NAD

HA 11 Domestic Cold Piping Insulation

BPI-07 NAD

BPI-08 NAD

BPI-09 NAD

HA 12 Domestic Cold Pipe Fittings

BPF-10 NAD

BPF-11 NAD

BPF-12 NAD

HA 13

Domestic Hot

Piping Insulation

BPI-13 NAD

BPI-14 NAD

BPI-15 NAD

HA 14 Domestic Hot Pipe Fittings

BPF-16 2% Amosite BPF-17 2% Amosite

BPF-18 NAD

HA 15

Low Pressure Steam

Piping Insulation

BPI-19 NAD

BPI-20 NAD

BPI-21 NAD

HA 16 Low Pressure Steam Pipe Fittings

BPF-22 NAD

BPF-23 NAD

BPF-24 NAD

HA 17 Soil

B1 NAD

B2 3.3% Amosite B3 3.8% Amosite B4 2.8% Amosite

Table 3

Crawl Space – Building B- Access through Mechanical Room GC-346 Atlanta VAMC, Decatur, GA

Collected on 2/7/25

Homogenous Area (Material)

(HA)

Suspect Asbestos- Containing Material

HA 18 Fireproofing

BFP-31 NAD

BFP-32 NAD

BFP-33 NAD

HA 19

Cold Water

Piping Insulation

BPI-34 NAD

BPI-35 NAD

BPI-36 NAD

HA 20

Cold Water Pipe Fittings

BPF-37 NAD

BPF-38 2% Chrysotile

BPF-39 NAD

HA 21

Hot Water

Piping Insulation

BPI-40 NAD

BPI-41 NAD

BPI-42 NAD

HA 22

Hot Water

Pipe Fittings

BPF-43 2% Amosite BPF-44 2% Amosite BPF-45 2% Amosite

HA 23 Duct Mastic

BDM-46 NAD

BDM-47 NAD

HA 24 Soil B5 3.5% Amosite B6 0.5% Amosite

B8 NAD

HA 25 Debris on Ground B7 NAD

Table 4 Suspect Asbestos-Containing Materials

Crawl Space – Building C – East Side, Accessible Near Room BC106I Atlanta VAMC, Decatur, GA

Collected on 1/29/25

Homogenous Area (Material)

(HA)

Suspect Asbestos- Containing Material

HA 26 Piping Insulation – ¾”

C-1 NAD

C-2 NAD

C-3 NAD

HA 27 Piping Insulation – 1”

C-4 NAD

C-5 NAD

C-6 NAD

C-7 NAD

C-8 NAD

C-9 4% Chrysotile – black mastic

HA 28 Piping Insulation – 2”

C-10 NAD

C-11 NAD

C-12 NAD

HA 29 Piping Insulation

C-13 NAD

C-14 NAD

C-15 NAD

HA 30 Fireproofing

C-16 NAD

C-17 NAD

C-31 NAD

HA 31 Foam Glass Piping Insulation

C-20 NAD

C-21 NAD

C-22 NAD

HA 32 Black Mastic

C-23 NAD

C-24 NAD

HA 33 Duct Insulation

C-25 NAD

C-26 NAD

C-27 NAD

HA 34 Fiberglass Piping Insulation

C-28 NAD

C-29 NAD

C-30 NAD

HA 35 Debris on Ground

C-18 NAD

C-19 NAD

C-32 NAD

C-33 NAD

C-34 NAD

C-35 NAD

C-36 NAD

C-37 NAD

C-38 NAD

C-39 NAD

C-40 NAD

Table 5

Crawl Space – Building C – West Side, Accessible through Room BA106 Atlanta VAMC, Decatur, GA

Collected on 1/30/25

Homogenous Area (Material)

(HA)

Suspect Asbestos- Containing Material

HA 36 Canvas Wrapped Piping Insulation

CCP-1 40% Chrysotile CCP-2 40% Chrysotile CCP-3 40% Chrysotile

HA 37 Gray Duct Mastic

CGD-1 NAD

CGD-2 NAD

HA 38 Transite-type Flue CTR-1 15% Chrysotile CTR-2 15% Chrysotile

HA 39 Fireproofing

CFP-1 NAD

CFP-2 NAD

CFP-3 NAD

HA 40 Fiberglass Piping Insulation

CPI-1 NAD

CPI-2 NAD

CPI-3 NAD

HA 41 Pipe Fitting Insulation CPF-1 3% Amosite CPF-2 3% Amosite CPF-3 3% Amosite

HA 42 Debris on Ground

CD-1 NAD

CD-2 NAD

CD-3 NAD

CD-4 NAD

CD-5 NAD

CD-6 NAD

CD-7 NAD

CD-8 NAD

CD-9 NAD

Notes:

1. NAD: No Asbestos Detected

2. If suspect ACM not identified in this report are encountered during disturbance activities, additional sampling may be warranted.

Summary of Identified Asbestos-Containing Materials

The results of laboratory analysis by PLM (or assumed ACM – see note 4. below) indicated asbestos was detected in the following specifically targeted suspect materials identified in tables 6-8 below.

Table 6

Identified Asbestos-Containing Materials Crawl Space – Building B- Access through Mechanical Room GC-347

Atlanta VAMC, Decatur, GA

Asbestos-Containing Material (ACM) Asbestos Content Quantity

OSHA

Class of Work (I or II)

NESHAP

Category

Pipe Fitting Insulation 2% Amosite 80-100 EA: <6” D Class I RACM

Soil

2.8 – 3.8 %

Amosite 20,000 SF Class I RACM

Table 7 Identified Asbestos-Containing Materials

Crawl Space – Building B- Access through Mechanical Room GC-346 Atlanta VAMC, Decatur, GA

Asbestos-Containing Material (ACM)

Asbestos Content Quantity

Pipe Fitting Insulation 2% Chrysotile 2% Amosite

125-150 EA: <6” D Class I RACM

Soil

0.5 – 3.5 %

Amosite 16,500 SF Class I RACM

Table 8 Identified Asbestos-Containing Materials

Crawl Space – Building C Atlanta VAMC, Decatur, GA

Asbestos-Containing Material (ACM)

Asbestos Content Quantity

Black Mastic on Fiberglass Piping

Insulation w/ Fittings 2% Chrysotile

175 LF Piping 30-50 Fittings:

<6” D

Mastic- Class II Fittings- Class I

Mastic- Cat I Fittings-

RACM

Canvas Wrapped Piping Insulation

40% Chrysotile 250 LF: 6” D Class I RACM

Transite-type Flue 15% Chrysotile

350 LF: <12” D

250 LF: >12” D Class II

RACM or Cat II

Pipe Fitting Insulation Assumed >1% 225-280 EA: <6” D Class I RACM

Notes:

1. LF – Linear Feet

2. EA – Each

3. D – Diameter

4. Quantities and Diameters are approximate.

5. Assumed >1% indicates the material tested positive in other locations or is historically presumed to contain asbestos.

6. “OSHA Class of Work” refers to the manner in which the abatement project will be conducted based on the material being abated as defined by OSHA.

a) Class I Asbestos Work - means activities involving the removal of thermal system insulation or surfacing material and PACM.

b) Class II Asbestos Work - means activities involving the removal of ACM which is not thermal system insulation or surfacing material. This includes, but is not limited to, the removal of asbestos-containing wallboard, floor tile and sheeting, roofing and siding shingles, and construction mastics.

7. “NESHAP Category” refers to the EPAs classification of ACM which can determine the notification, disturbance, or disposal requirements.

a) Regulated asbestos-containing material (RACM) means

i. Friable asbestos material,

ii. Category I nonfriable ACM that has become friable,

iii. Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or

iv. Category II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations regulated by this subpart.

b) Category I nonfriable asbestos-containing material (ACM) means asbestos-containing packings, gaskets, resilient floor covering, and asphalt roofing products containing more than 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763, section 1, Polarized Light Microscopy.

c) Category II nonfriable ACM means any material, excluding Category I nonfriable ACM, containing more than 1 percent asbestos as determined using the methods specified in appendix E, subpart E, 40 CFR part 763, section 1, Polarized Light Microscopy that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

Sampling Protocol and Methodology

This survey used substantial guidance from the AHERA sampling protocol.

The AHERA sampling protocol places suspect ACM in one of the following categories, to determine sample collection criteria:

• Surfacing Materials – Material that has been sprayed on, troweled on, or otherwise applied to surfaces (structural members, walls, ceilings, etc.) for acoustical, decorative, fireproofing, or other purposes.

• Thermal System Insulation (TSI) - Insulation used to control heat transfer or prevent condensation. Examples include insulation on piping systems, tanks, etc.

• Miscellaneous Materials - Materials that are not classified under surfacing or TSI are Miscellaneous materials (floor tile / mastic, roofing materials, caulks, etc.).

The survey protocol consists of identifying suspect ACM by homogeneous area or material (the terms area and material may be used interchangeably) and sampling each in accordance with the AHERA criteria, at a minimum.

A homogeneous material is defined as having similar color, texture, and general appearance. A homogeneous material may be in one location or multiple locations throughout a facility. The use of the material and the date of installation, if known, may further define a homogeneous material. It should be noted that the same descriptive material may consist of a separate homogenous area / material based on a different application.

In accordance with the AHERA protocol, all samples collected from a homogeneous area / material must be negative for the presence of asbestos, analyzed by polarized light microscopy (PLM), for the homogeneous material to be considered a non-asbestos-containing material https://www.ecfr.gov/current/title-40/part-763 https://www.ecfr.gov/current/title-40/part-763

Based on analytical results, the AHERA Inspector may redefine the homogenous material and sample accordingly for asbestos content determination.

Bulk samples are collected from suspect ACM identified during the field inspection activities.

The number of samples collected and a description for each homogeneous material is recorded, along with an estimated quantity and condition. The location of the homogenous material and each sample is recorded on sample logs and floor plans provided by the client or field sketches.

With the owner’s approval, some suspect materials (i.e., 9” x 9” floor tile, black flooring mastic, air cell-type insulation, roofing materials, concealed insulation, wiring insulation, fire doors, etc.) may be presumed to contain asbestos based primarily on 1) historical data, 2) knowledge and experience of the accredited Inspector and 3) inaccessibility during the survey phase.

Presumed ACM may be sampled later, typically in the abatement design phase, or treated as presumed ACM.

In accordance with NESHAP, materials determined to contain 1% or less asbestos content, by polarized light microscopy (PLM), can be treated as an asbestos-containing material (> 1 %) or point counted for confirmation the material does not contain greater than one percent (> 1 %) asbestos content. Materials containing one (1) % or less asbestos content, confirmed by point counting, do not fall under NESHAP notification, disturbance, or disposal requirements but do fall under Occupational Safety and Health Administration (OSHA) and EPA worker protection requirements, and other regulations may be applicable.

Technical Requirements

Field inspection and sampling was conducted by Environmental Protection Agency (EPA) Asbestos Hazard Emergency Response Act (AHERA) accredited Inspectors. Sample analysis was performed utilizing polarized light microscopy (PLM) by a laboratory that successfully participates in the National Institute of Standards and Technology (NIST), National Voluntary Laboratory Accreditation Program (NVLAP).

PEM’s industrial hygiene asbestos program is managed by an EPA AHERA accredited Supervisor, Designer, and Inspector and Management Planner, with technical oversight by a Certified Industrial Hygienist (CIH). The project was conducted under the direction of an “Environmental Professional” meeting the definition in Appendix X2 of American Society for Testing and Materials (ASTM) international, Standard Practices E1527-21.

This inspection complied with pre-renovation / demolition inspection requirements of 40 CFR Part 61, Subpart M, National Emission Standards for Hazardous Air Pollutants (NESHAP). The survey protocol utilizes substantial guidance from ASTM International Standard Practice for Comprehensive Building Asbestos Surveys (ASTM E2356-18).

Findings Summary and Recommendations

Survey results and findings observed and/or found during this survey identified asbestos in the following materials and locations:

Crawl Space – Building B (accessible through mechanical room GC 347)

• Soil

Crawl Space – Building B (accessible through mechanical room GC 346)

• Soil

Crawl Space – Building C

• Mastic on Fiberglass Piping Insulation

• Canvas Wrapped Piping Insulation

• Transite-Type Flue

Based on the above findings, an asbestos abatement design is recommended.

Appendix A

PLM Laboratory Report, including Chain of Custody

Bulk Asbestos Analysis By Polarized Light Microscopy EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10074920Customer: Professional Environmental Management 3915 Harrison Road Suite 400 Loganville, GA 30052

Analysis:

Date Received:

Erin Garmon

PLM

02/12/2025

Project: Atlanta VA, Crawl Space - Bldg A Date Reported: 02/14/2025

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

ADM-01

10074920_0002

Gray Duct Mastic

None Detected 100% Other

Non-Fibrous

Crushed, Dissolved

Gray

Homogeneous

ADM-02

10074920_0003

Gray Duct Mastic

None Detected 100% Other

Non-Fibrous

Dissolved

Gray

Homogeneous

AFP-03

10074920_0004

Fireproofing

None Detected 35% Cellulose 65% Other

Fibrous

Teased

Gray

Homogeneous

AFP-04

10074920_0005

Fireproofing

None Detected 35% Cellulose 65% Other

Fibrous

Teased

Gray

Homogeneous

AFP-05

10074920_0006

Fireproofing

None Detected 35% Cellulose 65% Other

Fibrous

Teased

Gray

Homogeneous

AFP-06

10074920_0007

Fireproofing

None Detected 35% Cellulose 65% Other

Fibrous

Teased

Gray

Homogeneous

AFP-07

10074920_0008

Fireproofing

None Detected 35% Cellulose 65% Other

Fibrous

Teased

Gray

Homogeneous

AFP-08

10074920_0009

Fireproofing

None Detected 35% Cellulose 65% Other

Fibrous

Teased

Gray

Homogeneous

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Charmel Dozier (24)

Analyst Approved Signatory

Page 1 of 3P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10074920Customer: Professional Environmental Management 3915 Harrison Road Suite 400 Loganville, GA 30052

Analysis:

Date Received:

Erin Garmon

PLM

02/12/2025

Project: Atlanta VA, Crawl Space - Bldg A Date Reported: 02/14/2025

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

AFP-09

10074920_0010

Fireproofing

None Detected 35% Cellulose 65% Other

Fibrous

Teased

Gray

Homogeneous

ACW-10

10074920_0011

Chill Water System Pipe Insulation

None Detected 40% 20% 5%

Fiber Glass Cellulose Wollastonite

35% Other

Fibrous

Ashed

White, Yellow

Homogeneous wrap on fiberglass insulation

ACW-11

10074920_0012

Chill Water System Pipe Insulation

None Detected 40% 20% 5%

Fiber Glass Cellulose Wollastonite

35% Other

Fibrous

Ashed

Yellow, White

Homogeneous wrap on fiberglass insulation

ACW-12

10074920_0013

Chill Water System Pipe Insulation

None Detected 15% 5% 5%

Fiber Glass Cellulose Wollastonite

75% Other

Fibrous

Ashed

White

Homogeneous wrap on wood block

AST-13

10074920_0014

Steam System Pipe Insulation

None Detected 50% 30%

Fiber Glass Cellulose

20% Other

Fibrous

Ashed

Yellow, White

Homogeneous wrap on fiberglass

AST-14

10074920_0015

Steam System Pipe Insulation

None Detected 50% 3% 2%

Fiber Glass Wollastonite Cellulose

45% Other

Fibrous

Ashed

White, Yellow

Homogeneous wrap on fiberglass

AST-15

10074920_0016

Steam System Pipe Insulation

None Detected 50% 30%

Fiber Glass Cellulose

20% Other

Fibrous

Ashed

White, Yellow

Homogeneous wrap on fiberglass

ASC-16

10074920_0017

Steam Condensate Piping

None Detected 40% 30% 3%

Fiber Glass Cellulose Wollastonite

27% Other

Fibrous

Ashed

Yellow, White

Homogeneous wrap on fiberglass

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Charmel Dozier (24)

Page 2 of 3P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10074920Customer: Professional Environmental Management 3915 Harrison Road Suite 400 Loganville, GA 30052

Analysis:

Date Received:

Erin Garmon

PLM

02/12/2025

Project: Atlanta VA, Crawl Space - Bldg A Date Reported: 02/14/2025

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

ASC-17

10074920_0018

Steam Condensate Piping

None Detected 50% 30%

Fiber Glass Cellulose

20% Other

Fibrous

Ashed

Yellow, White

Homogeneous wrap on fiberglass

ASC-18

10074920_0019

Steam Condensate Piping

None Detected 50% 30%

Fiber Glass Cellulose

20% Other

Fibrous

Ashed

White, Yellow

Homogeneous wrap on fiberglass

ADHW-19

10074920_0020

Domestic Hot Water Piping

None Detected 50% 30%

Fiber Glass Cellulose

20% Other

Fibrous

Ashed

Yellow, White

Homogeneous wrap on fiberglass

ADHW-20

10074920_0021

Domestic Hot Water Piping

None Detected 50% 30%

Fiber Glass Cellulose

20% Other

Fibrous

Ashed

White, Yellow

Homogeneous wrap on fiberglass

ADHW-21

10074920_0022

Domestic Hot Water Piping

None Detected 50% 30%

Fiber Glass Cellulose

20% Other

Fibrous

Ashed

Yellow, White

Homogeneous wrap on fiberglass

ADCW-22

10074920_0023

Domestic Cold Water Piping

None Detected 50% 30%

Fiber Glass Cellulose

20% Other

Fibrous

Ashed

White, Yellow

Homogeneous wrap on fiberglass

ADCW-23

10074920_0024

Domestic Cold Water Piping

None Detected 50% 30%

Fiber Glass Cellulose

20% Other

Fibrous

Ashed

White, Yellow

Homogeneous wrap on fiberglass

ADCW-24

10074920_0025

Domestic Cold Water Piping

None Detected 50% 30%

Fiber Glass Cellulose

20% Other

Fibrous

Ashed

White

Homogeneous wrap on fiberglass

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Charmel Dozier (24)

Page 3 of 3P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Cllent:

Contact:

Address:

Phone:

Fax:

Email:

Project:

Client Notes:

P.O.#.

Date Submitted:

Analysts:

TurnAroundTime:

ISample Number <c <<

ADM-01

ADM-02

AFP-03

AFP-04

AFP-05

AFP-06

AFP-07

AFP-08

AFP-09

ACW-10

ACW-11

ACW-12

AST-13

AST-14

AST-15

ASC-16

Relinquished By

\b"b1Uqi,o Professional Environmental Manag, •1natr11ctlons:

Erin Garmon Use Column -s• for your contact info 3915 Harrison Road, STE 400, Loganville, GA 30052 678-687 -4630 I To See an Example Click the [Enter fax here] bottom Example Tab.

engarmon@gem-en~.com

Enter samples between •cc• and ">>" Atlanta VA, Crawl Space - Bldg A peg1n Sampl• with a •c< •at,ove the first samplt Sdentfflc and end with• ">>• below the last sample. I Analytical Only Enter your data on the first sheet •sheet1 • Institute OJ>J

[Enter P.O. # Here]

PLM

5 day_

Data1

2/12/2025 0:00 Note: Data 1 and Data 2 are optional fields that do not show up on the official report, however they will be included in the electronic data returned to you to facilitate vour reintearatlon of the report data.

Sample Description

Grav Duct Mastic Grav Duct Mastic Fireoroofina Fireoroofina Fireoroofina Fireoroofina Fireoroofina Fireoroofina Fireoroofina Chill Water Svstem Pioe Insulation Chill Water Svstem Pioe Insulation Chill Water Svstem Pipe Insulation Steam System Pioe Insulation Steam System Pioe Insulation Steam Svstem Pioe Insulation ~ Steam Condensate PipinQ _I\ \; I;)

4604 Dundas Drive Greensboro, NC 27407 Phone: 336.292.3888

Fax: 336.292.33l3 Email: labOsailab.com

Data2

Collected 1 /30/25 Collected 1/30/25 Collected 1 /30/25 Collected 1 /30/25 Collected 1 /30/25 Collected 1 /30/25 Collected 1 /30/25 Collected 1 /30/25 Collected 1/30/25 Collected 1/30/25 Collected 1/30/25 Collected 1/30/25 Collected 1 /30/25 Collected 1 /30/25 Collected 1 /30/25 Collected 1/30/25

Received By

1,-\·i \n:WCWV\..- Ricky Garmon __________ _

~Gr,eF---:V '!.,,0~

~e\eG ~ le tr1 t;t 01 ~-o ASC-17 Steam Condensate Pipino Collected 1/30/25

ASC-18 Steam Condensate Pipino Collected 1 /30/25

ADHW-19 Domestic Hot Water Piping Collected 1/30/25

ADHW-20 Domestic Hot Water Pipino Collected 1/30/25

ADHW-21 Domestic Hot Water Pioina Collected 1 /30/25

ADCW-22 Domestic Cold Water Pipino Collected 1/30/25

ADCW-23 Domestic Cold Water Pipino Collected 1/30/25

ADCW-24 Domestic Cold Water Piping Collected 1 /30/25

Received By

Relinquished By Ricky Garmon __________ _

Determination of Asbestos Content by Polarized Light Microscopy

California Air Resources Board (CARB) Method 435; to 0.1%*

Client: Professional Environmental Management

Attn: Erin Garmon Lab Order ID: 10074929

3915 Harrison Road Suite 408 Date Received: 02/12/2025 Loganville, GA 30052 Date Reported: 02/19/2025 Project: Atlanta VA, Crawl Space - Bldg A Page: 1 of 1

Byron Stroble ___________________________________ Analyst Lab Director

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

P-F-005 EXP: 3/1/2023

Sample ID Description

ASBESTOS

Lab Sample ID Lab Notes

AS-01 Soil None Detected

AS-02 Soil

AS-03 Soil

AS-04 Soil

AS-05 Soil

AS-06 Soil

Notes: The CARB 435 method was designed as applicable to the determination of asbestos in ultramafic or serpentine rock aggregates. The detection limit of 0.1% is based on 1,000 points counted on a petrographic microscope (PLM), of a representative rock flour of the sample(s) submitted. These results apply only to the material as submitted to SAI, Inc.

Client:

Address:

Phone:

Fax:

Email:

Project:

Client Notes:

P.O.#.

Date Submitted:

Analysis:

TurnAroundTime:

[Sample Number

AS-01

AS-02

AS-03

AS-04

AS-05

AS-06

Relinquished By

Professional Environmental Manag, *Instructions:

Erin Garmon Use Column "Bn for your contact info

\tD\Yq19 3915 Harrison Road, STE 400, Loganville, GA 30052 678-687-4630 I To See an Example Click the [Enter fax here] bottom Example Tab.

engarmon@pem-env.com

Enter samples between "<<" and ">>" Atlanta VA, Crawl Space - Bldg A pegin Samples with a "<< "above the first samplE Scientific and end with a ">>" below the last sample. I Analytical

[Enter P.O. # Here] 2/12/2025 0:00

Soil 5 day

Data 1

Only Enter your data on the first sheet "Sheet1" Institute

Note: Data 1 and Data 2 are optional fields that do not show up on the official report, however they will be included in the electronic data returned to you to facilitate your reintegration of the report data.

Sampl~ .. D~scription

Soil Soil Soil Soil Soil Soil

A-

4604 Dundas Drive Greensboro, NC 27407 Phone: 336.292.3888

Fax: 336.292.3313 Email: lab@sailab.com

Data 2

Collected 2/4/25 Collected 2/4/25 Collected 2/4/25 Collected 2/4/25 Collected 2/4/25 Collected 2/4/25

J r ~ Received By

Ricky Garmon __________ _ f}j 1-i I D -?J

0CLW-J

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10074918Customer: Professional Environmental Management 3915 Harrison Road Suite 400 Loganville, GA 30052

Analysis:

Date Received:

Date Amended:

Erin Garmon

PLM

02/12/2025

Project: Atlanta VA, Crawl Space - Bldg B. 2/7/2025 Date Reported: 02/19/2025

02/20/2025

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

BFP-01

10074918_0002

Fireproofing

None Detected 80% Fiber Glass 20% Other

Fibrous

Teased

Gray

Homogeneous

BFP-02

10074918_0003

Fireproofing

None Detected 80% Fiber Glass 20% Other

Fibrous

Teased

Gray

Homogeneous

BFP-03

10074918_0004

Fireproofing

None Detected 80% Fiber Glass 20% Other

Fibrous

Teased

Gray

Homogeneous

BFP-04

10074918_0005

Fireproofing

None Detected 80% Fiber Glass 20% Other

Fibrous

Teased

Gray

Homogeneous

BDM-05

10074918_0006

Duct Mastic

None Detected 100% Other

Non-Fibrous

Ashed

Gray

Homogeneous

BDM-06

10074918_0007

Duct Mastic

None Detected 100% Other

Non-Fibrous

Ashed

Gray

Homogeneous

BPI-07 - A

10074918_0008

Domestic Cold

None Detected 40% 40%

Fiber Glass Cellulose

20% Other

Fibrous

Teased

White, Silver

Homogeneous wrap/mastic

BPI-07 - B

10074918_0043

Domestic Cold

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Patrick Yarnell (61)

Page 1 of 8P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10074918Customer: Professional Environmental Management 3915 Harrison Road Suite 400 Loganville, GA 30052

Analysis:

Date Received:

Date Amended:

Erin Garmon

PLM

02/12/2025

Project: Atlanta VA, Crawl Space - Bldg B. 2/7/2025 Date Reported: 02/19/2025

02/20/2025

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

BPI-08 - A

10074918_0009

Domestic Cold

None Detected 20% 20%

Fiber Glass Cellulose

60% Other

Fibrous

Ashed

White, Silver

Homogeneous wrap/mastic

BPI-08 - B

10074918_0044

Domestic Cold

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

BPI-09 - A

10074918_0010

Domestic Cold

None Detected 20% 20%

Fiber Glass Cellulose

60% Other

Fibrous

Ashed

White, Silver

Homogeneous wrap/mastic

BPI-09 - B

10074918_0045

Domestic Cold

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

BPF-10

10074918_0011

Domestic Cold Fittings

None Detected 80% Mineral Wool 20% Other

Non-Fibrous

Dissolved

Gray

Homogeneous

BPF-11

10074918_0012

Domestic Cold Fittings

None Detected 80% Mineral Wool 20% Other

Non-Fibrous

Dissolved

Gray

Homogeneous

BPF-12 - A

10074918_0013

Domestic Cold Fittings

None Detected 95% Cellulose 5% Other

Fibrous

Teased

Tan

Homogeneous wrap/mastic 1

BPF-12 - B

10074918_0046

Domestic Cold Fittings

None Detected 80% Mineral Wool 20% Other

Non-Fibrous

Crushed

Gray

Homogeneous insulation

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Patrick Yarnell (61)

Page 2 of 8P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10074918Customer: Professional Environmental Management 3915 Harrison Road Suite 400 Loganville, GA 30052

Analysis:

Date Received:

Date Amended:

Erin Garmon

PLM

02/12/2025

Project: Atlanta VA, Crawl Space - Bldg B. 2/7/2025 Date Reported: 02/19/2025

02/20/2025

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

BPF-12 - C

10074918_0047

Domestic Cold Fittings

None Detected 40% 40%

Cellulose Fiber Glass

20% Other

Fibrous

Teased

White, Black

Homogeneous wrap/mastic 2

BPF-12 - D

10074918_0048

Domestic Cold Fittings

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation 2

BPI-13 - A

10074918_0014

Domestic Hot

None Detected 40% 40%

Mineral Wool Cellulose

20% Other

Fibrous

Ashed

Silver, White

Homogeneous wrap/mastic

BPI-13 - B

10074918_0049

Domestic Hot

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

BPI-14 - A

10074918_0015

Domestic Hot

None Detected 40% 40%

Mineral Wool Cellulose

20% Other

Fibrous

Ashed

Silver, White

Homogeneous wrap/mastic

BPI-14 - B

10074918_0050

Domestic Hot

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

BPI-15 - A

10074918_0016

Domestic Hot

None Detected 40% 40%

Cellulose Fiber Glass

20% Other

Fibrous

Ashed

White, Silver

Homogeneous wrap/mastic

BPI-15 - B

10074918_0051

Domestic Hot

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Patrick Yarnell (61)

Page 3 of 8P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10074918Customer: Professional Environmental Management 3915 Harrison Road Suite 400 Loganville, GA 30052

Analysis:

Date Received:

Date Amended:

Erin Garmon

PLM

02/12/2025

Project: Atlanta VA, Crawl Space - Bldg B. 2/7/2025 Date Reported: 02/19/2025

02/20/2025

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

BPF-16

10074918_0017

Domestic Hot Fittings

78%2% Amosite Mineral Wool 20% Other

Non-Fibrous

Crushed

Gray

Homogeneous

BPF-17

10074918_0018

Domestic Hot Fittings

78%2% Amosite Mineral Wool 20% Other

Non-Fibrous

Crushed

Gray

Homogeneous

BPF-18

10074918_0019

Domestic Hot Fittings

None Detected 80% Mineral Wool 20% Other

Non-Fibrous

Crushed

Gray

Homogeneous

BPI-19 - A

10074918_0020

Low Pressure Steam

None Detected 20% 20%

Cellulose Fiber Glass

60% Other

Fibrous

Ashed

White, Silver

Homogeneous wrap/mastic

BPI-19 - B

10074918_0052

Low Pressure Steam

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

BPI-20 - A

10074918_0021

Low Pressure Steam

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

BPI-20 - B

10074918_0053

Low Pressure Steam

None Detected 100% Other

Non-Fibrous

Dissolved

Black

Homogeneous tar

BPI-21 - A

10074918_0022

Low Pressure Steam

None Detected 20% 20%

Fiber Glass Cellulose

60% Other

Fibrous

Ashed

White, Silver

Homogeneous wrap/mastic

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Patrick Yarnell (61)

Page 4 of 8P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10074918Customer: Professional Environmental Management 3915 Harrison Road Suite 400 Loganville, GA 30052

Analysis:

Date Received:

Date Amended:

Erin Garmon

PLM

02/12/2025

Project: Atlanta VA, Crawl Space - Bldg B. 2/7/2025 Date Reported: 02/19/2025

02/20/2025

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

BPI-21 - B

10074918_0054

Low Pressure Steam

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

BPF-22 - A

10074918_0023

Low Pressure Steam Fittings

None Detected 95% Cellulose 5% Other

Fibrous

Teased

Tan

Homogeneous wrap

BPF-22 - B

10074918_0055

Low Pressure Steam Fittings

None Detected 80% Mineral Wool 20% Other

Non-Fibrous

Crushed

Gray

Homogeneous insulation

BPF-23

10074918_0024

Low Pressure Steam Fittings

None Detected 80% Mineral Wool 20% Other

Non-Fibrous

Crushed

Gray

Homogeneous

BPF-24 - A

10074918_0025

Low Pressure Steam Fittings

None Detected 99% Cellulose 1% Other

Fibrous

Teased

Tan

Homogeneous wrap

BPF-24 - B

10074918_0056

Low Pressure Steam Fittings

None Detected 80% Mineral Wool 20% Other

Non-Fibrous

Crushed

Gray

Homogeneous insulation

BFP-31

10074918_0026

Fireproofing

None Detected 80% Mineral Wool 20% Other

Fibrous

Dissolved

Gray

Homogeneous

BFP-32

10074918_0027

Fireproofing

None Detected 80% Mineral Wool 20% Other

Fibrous

Dissolved

Gray

Homogeneous

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Patrick Yarnell (61)

Page 5 of 8P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10074918Customer: Professional Environmental Management 3915 Harrison Road Suite 400 Loganville, GA 30052

Analysis:

Date Received:

Date Amended:

Erin Garmon

PLM

02/12/2025

Project: Atlanta VA, Crawl Space - Bldg B. 2/7/2025 Date Reported: 02/19/2025

02/20/2025

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

BFP-33

10074918_0028

Fireproofing

None Detected 80% Mineral Wool 20% Other

Fibrous

Dissolved

Gray

Homogeneous

BPI-34 - A

10074918_0029

Cold Water Runs

None Detected 40% 40%

Cellulose Fiber Glass

20% Other

Fibrous

Ashed

White, Silver

Homogeneous wrap/mastic

BPI-34 - B

10074918_0057

Cold Water Runs

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

BPI-35 - A

10074918_0030

Cold Water Runs

None Detected 40% 40%

Fiber Glass Cellulose

20% Other

Fibrous

Ashed

White, Silver

Homogeneous wrap/mastic

BPI-35 - B

10074918_0058

Cold Water Runs

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

BPI-36 - A

10074918_0031

Cold Water Runs

None Detected 40% 40%

Fiber Glass Cellulose

20% Other

Fibrous

Ashed

White, Silver

Homogeneous wrap/mastic

BPI-36 - B

10074918_0059

Cold Water Runs

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

BPF-37

10074918_0032

Cold Water Fittings

None Detected 80% Mineral Wool 20% Other

Fibrous

Crushed

Gray

Homogeneous

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Patrick Yarnell (61)

Page 6 of 8P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10074918Customer: Professional Environmental Management 3915 Harrison Road Suite 400 Loganville, GA 30052

Analysis:

Date Received:

Date Amended:

Erin Garmon

PLM

02/12/2025

Project: Atlanta VA, Crawl Space - Bldg B. 2/7/2025 Date Reported: 02/19/2025

02/20/2025

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

BPF-38

10074918_0033

Cold Water Fittings

80%2% Chrysotile Mineral Wool 18% Other

Non-Fibrous

Crushed

Gray

Homogeneous

BPF-39

10074918_0034

Cold Water Fittings

None Detected 80% Mineral Wool 20% Other

Fibrous

Crushed

Gray

Homogeneous

BPI-40 - A

10074918_0035

Hot Water Runs

None Detected 70% 10%

Cellulose Fiber Glass

20% Other

Fibrous

Ashed

White, Silver

Homogeneous wrap

BPI-40 - B

10074918_0060

Hot Water Runs

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

BPI-41 - A

10074918_0036

Hot Water Runs

None Detected 70% 10%

Cellulose Fiber Glass

20% Other

Fibrous

Ashed

White, Silver

Homogeneous wrap

BPI-41 - B

10074918_0061

Hot Water Runs

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

BPI-42 - A

10074918_0037

Hot Water Runs

None Detected 70% 10%

Cellulose Fiber Glass

20% Other

Fibrous

Ashed

White, Silver

Homogeneous wrap

BPI-42 - B

10074918_0062

Hot Water Runs

None Detected 99% Fiber Glass 1% Other

Fibrous

Teased

Yellow

Homogeneous insulation

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Patrick Yarnell (61)

Page 7 of 8P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10074918Customer: Professional Environmental Management 3915 Harrison Road Suite 400 Loganville, GA 30052

Analysis:

Date Received:

Date Amended:

Erin Garmon

PLM

02/12/2025

Project: Atlanta VA, Crawl Space - Bldg B. 2/7/2025 Date Reported: 02/19/2025

02/20/2025

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

BPF-43

10074918_0038

Hot Water Fittings

78%2% Amosite Mineral Wool 20% Other

Non-Fibrous

Crushed

Gray

Homogeneous

BPF-44

10074918_0039

Hot Water Fittings

78%2% Amosite Mineral Wool 20% Other

Non-Fibrous

Crushed

Gray

Homogeneous

BPF-45

10074918_0040

Hot Water Fittings

78%2% Amosite Mineral Wool 20% Other

Non-Fibrous

Crushed

Gray

Homogeneous

BDM-46

10074918_0041

Duct Mastic

None Detected 5% Wollastonite 95% Other

Non-Fibrous

Ashed

Red

Homogeneous

BDM-47

10074918_0042

Duct Mastic

None Detected 5% Wollastonite 95% Other

Non-Fibrous

Ashed

Red

Homogeneous

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Patrick Yarnell (61)

Page 8 of 8P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

BFP-01

BFP-02

BFP-03

BFP-04

BDM-05

BDM-06

BPl-07 BPl-08 BPl-09

BPF-10

BPF-11

BPF-12

BPl-13 BPl-14 BPl-15

BPF-16

Relinquished By Ricky Garmon

.µJ\J Professional Environmental Manag Erin Garmon 3915 Harrison Road, STE 400, Log 678-687-4630 [Enter fax here] enqarmon@pem-env.com

Atlanta VA, Crawl Space - Bldg B.

2/7/2025

[Enter P.O. # Here] 2/12/2025 0:00

I 001Lf0J/8

Fireoroofina Collected on 2/7/25 Fireoroofina Collected on 2/7 /25 Fireoroofina Collected on 2/7 /25 Duct Mastic Collected on 2/7 /25 Duct Mastic Collected on 2/7 /25 Domestic Cold Collected on 2/7 /25 Domestic Cold Collected on 2/7 /25 Domestic Cold Collected on 2/7 /25 Domestic Cold Fittinas Collected on 2/7 /25 Domestic Cold Fittinas Collected on 2/7 /25 Domestic Cold Fittings Collected on 2/7 /25 Domestic Hot Collected on 2/7 /25 Domestic Hot Collected on 2/7 /25 Domestic Hot ··· .

Collected on 2/7/25 Dome#ic Hot Fittings Collected on 2/7/25

Received By .

v(l 1 Rejected □ J-7o y ·q { §

BPF-17 Domestic Hot Fittinqs Collected on 217125 BPF-18 Domestic Hot Fittings Collected on 217125 BPl-19 Low Pressure Steam Collected on 2/7 /25 BPl-20 Low Pressure Steam Collected on 217125 BPl-21 Low Pressure Steam Collected on 217125 BPF-22 Low Pressure Steam Fittings Collected on 217125 BPF-23 Low Pressure Steam Fittings Collected on 2/7/25 BPF-24 Low Pressure Steam Fittings Collected on 2/7 /25 BFP-31 Fireproofing Collected on 2/7 /25 BFP-32 Fireproofinq Collected on 217125 BFP-33 Fireproofing Collected on 2/7 /25 BPl-34 Cold Water Runs Collected on 2/7 /25 BPl-35 Cold Water Runs Collected on 2/7 /25 BPl-36 Cold Water Runs Collected on 2/7 /25 BPF-37 Cold Water Fittings Collected on 2/7 /25 BPF-38 Cold Water Fittings Collected on 217125 BPF-39 Cold Water Fittings Collected on 2/7 /25 BPl-40 Hot Water Runs Collected on 2/7/25 BPl-41 Hot Water Runs Collected on 217125 BPl-42 Hot Water Runs Collected on 2/7125 BPF-43 Hot Water Fittings Collected on 217125 BPF-44…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .