557-21-101 _VEG 26.09_ Addendum 3 Dwgs_Food Service.pdf
PDF 10 MB Posted
- Attached to
- Y1DZ--FY26 NRM|557-21-101|36C247-26-AP-0572|Correct Safety & FCA Def Bldg. 2| CONSTRUCTION
- Solicitation number
- 36C24726R0033
About this file
This is a set of architectural drawing addendums and food service equipment plans for a Veterans Affairs hospital kitchen renovation project located at 1826 Veterans Boulevard, Dublin, Georgia. The drawings are part of Project 557-21-101, which addresses safety and FCA (Food and Consideration Act) deficiencies in Building 2, and represent the third review submission at 95% design completion for mechanical and structural phases.
The drawings detail comprehensive food service equipment layouts, building conditions, ventilation plans, plumbing rough-ins, and electrical rough-ins across multiple kitchen areas including storage (dry storage, coolers, freezers), prep areas, cooking stations, patient tray assembly, serving areas, warewashing, and cart washing. Equipment specifications indicate a mix of contractor-provided/installed items, VA-provided/contractor-installed items, and VA-provided/VA-installed items, including refrigeration units, cooking equipment (kettles, ovens, ranges, grills, fryers), serving counters, dishwashing machines, and various food preparation fixtures. The electrical system is designed for 120/208 volts, three-phase, four-wire, 60-hertz service. Critical requirements include provisions for walk-in cooler and freezer floor depressions with specific insulation and reinforcement details, fire suppression systems integrated with exhaust hoods, specialized plumbing rough-ins with floor drains and troughs, and coordination among mechanical, plumbing, electrical, and general contractors. The design emphasizes food safety standards with non-combustible wall construction at cook lines, stainless steel corner guards, smooth and cleanable surfaces with coved base molding, and compliance with NFPA codes and local building standards.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:1
P
M
QF001
FOOD SERVICE NOTES & LEGENDS CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 1 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
MECHANICAL & STRUCTURAL KEY LEGEND
MAKE-UP AIR DUCT CONNECTION
EXHAUST DUCT CONNECTION
AIR COOLING (HEAT REMOVAL)
FLOOR AREA SPECIAL NOTES
NON-COMBUSTIBLE WALL (BY GENERAL
CONTRACTOR)
FLOOR DEPRESSION - SEE DETAIL PROVIDED
PLUMBING SYMBOL LEGEND
HOT/COLD WATER CONNECTION
DIRECT WASTE ROUGH-IN
FLOOR SINK - HALF GRATE
FIELD CONNECTIONS
FLOOR DRAIN
HOT/COLD WATER ROUGH-IN
ELECTRICAL SYMBOL LEGEND
WALL MOUNTED SIMPLEX RECEPTACLE
120 VOLT, GROUND TYPE
WALL MOUNTED DUPLEX RECEPTACLE
120 VOLT, GROUND TYPE
WALL MOUNTED SPECIAL PURPOSE OUTLET
208 VOLT, GROUND TYPE
WALL MOUNTED SPECIAL PURPOSE OUTLET
480 VOLT, GROUND TYPE
CEILING MOUNTED RECEPTACLE
120 VOLT, GROUND TYPE
FLOOR MOUNTED RECEPTACLE
120 VOLT, GROUND TYPE
JUNCTION BOX
DROP CORD SPECIAL PURPOSE OUTLET
208 VOLT, GROUND TYPE
DROP CORD, DUPLEX RECEPTACLE
120 VOLT, GROUND TYPE, DROPPED TO 6'-6" A.F.F.
DISCONNECT BOX
FLOOR MOUNTED RECEPTACLE
208 VOLT, GROUND TYPE
S SWITCH
VAPOR-PROOF LIGHT
DATA AND TELEPHONE CONNECTION
SYMBOLS LEGEND
1. SEE GENERAL SHEET GI003 FOR OVERALL PHASING PLAN.
2. SEE SHEET QF600 FOR UTILITY INFORMATION.
3. CONTRACTOR RESPONSIBLE FOR EQUIPMENT LEAD TIMES BASED
ON INSTALLATION SCHEDULE AND PHASING.
KITCHEN BUILDING CONDITIONS & VENTILATION NOTES
1. KITCHEN AREAS INCLUDING KITCHEN STORAGE WALK-INS, PREP AREAS, COOKING
AREAS, AND WARE WASH REQUIRES STRUCTURAL FLOOR TO SAFELY HANDLE HEAVY
FOODSERVICE EQUIPMENT PER BUILDING CODE.
2. ROUGH-IN/CONNECTION HEIGHTS NOTED ON THE MECHANICAL CONNECTION SCHEDULE
INDICATE HEIGHT ABOVE FINISHED FLOOR (AFF)
3. ASSURE THE FOLLOWING AMONGST THE TRADES:
A. IN-WALL REINFORCING OR BACKING AS REQUIRED FOR WALL MOUNTED KITCHEN
EQUIPMENT, COORDINATE SIZE, MOUNTING HEIGHTS AND INSTALLATION
REQUIREMENTS WITH CONTRACTOR MOUNT SHELVES AT 54" AND 66" -A.F.F.,
UNLESS OTHERWISE NOTED.
B. FOR WALKS IN COOLERS/FREEZERS PROVIDE SMOOTH AND LEVEL FLOOR
SURFACE.
C. PROVIDE FIRE-RATED MATERIALS AND/OR INSULATION FOR EXHAUST DUCTS, VENT
STACKS, PORTION OF EXHAUST HOODS ABOVE CEILING HEIGHT, HEAT PRODUCING
EQUIPMENT, ROOF/WALL PENETRATIONS.
4. MOUNT STAINLESS STEEL CORNER GUARDS ON EXTERNAL CORNERS OF INTERIOR
WALLS, PARTITIONS AND COLUMNS AS SHOW IN ARCHITECTURAL PLANS.
PLUMBING ROUGH-IN PLANS:
1. ROUGH-INS & CONNECTIONS SHOWN RELATE TO FOOD SERVICE EQUIPMENT ONLY.
PLUMBING DRAWINGS FOR ADDITIONAL REQUIREMENTS.
2. THIS PLUMBING PLAN IS INTENDED TO SHOW PRELIMINARY ROUGH-IN LOCATIONS &
HEIGHTS, CONNECTION SIZES & LOAD REQUIREMENTS.
3. FINAL CONNECTIONS TO FOOD SERVICE EQUIP. SHALL BE BY THE CONTRACTOR,
INCLUDING REQUIRED MATERIALS, SUCH AS STOPS, VALVES, FILTERS, TRAPS, CHECK
VALVES, PIPING, TUBING, ETC. UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
FURNISH BRASS BALL VALVE STOPS TO H/C WATER CONNECTIONS IN ACCORD WITH SIZE
OF FEED PIPE.
4. CONTRACTOR SHALL FURNISH & INSTALL THE FOLLOWING:
A. WATER, WASTE, GAS, STEAM, & AIR SERVICE FROM THE POINT OF ROUGH-IN TO
THE FOOD SERVICE FIXTURE & EQUIP. ITEMS AS SHOWN ON THE PLAN. ROUGH-IN
OUTLETS TO STUB 2" OUT OF WALLS AT HEIGHT INDICATED TO CENTERLINE OF
OUTLET. FLOOR ROUGH-INS TO STUB UP 4" (100 mm) A.F.F. OR CURB. FLOOR
OPENINGS &/OR PENETRATIONS SHALL BE WATER TIGHT & FIRE CAULKED .
B. FLOOR SINKS, COMPLETE GRATES, UNLESS OTHERWISE NOTED, & REMOVABLE
SEDIMENT BUCKETS SET FLUSH WITH FINISHED FLOOR, UNLESS OTHERWISE NOTED
OR REQUIRED BY CODE.
C. WASTE LINES, DIRECT & INDIRECT, EXCEPT AS NOTED OTHERWISE. MINIMUM
DIAMETER OF LINES SHALL BE AS NOTED IN THE PLUMBING CONNECTION
SCHEDULE, REGARDLESS OF CONNECTION SIZE, & SHALL BE PITCHED DOWNWARD.
MAINTAIN DRAINS AS HIGH AS POSSIBLE ABOVE FLOOR. PROVIDE CLEAN-OUTS ON
WASTE LINES.
D. INDIRECT WASTE LINES FOR WALK-IN REFRIGERATED BOXES SHALL BE
PITCHED A MINIMUM OF 1/4" PER FOOT WITH A "P" TRAP AT END OVER FLOOR SINK.
PIPING ON EXTERIOR SHALL BE PARALLEL TO WALK-IN. PENETRATE WALK-IN WALL
WITH WASTE LINE AT 1'-0" (300 mm) A.F.F.
E. INSTALL FIRE PROTECTION SYSTEM GAS SHUT-OFF VALVE(S), FURNISHED BY
THE CONTRACTOR, WHEN GAS COOKING EQUIP. IS USED.
ELECTRICAL ROUGH-IN PLAN:
1. ELECTRICAL SYSTEM IS DESIGNED FOR 120/208 VOLTS, 3 PHASE, 4 WIRE, 60 HERTZ,
UNLESS OTHERWISE NOTED.
2. OUTLETS & CONNECTIONS SHOWN RELATE TO FOOD SERVICE EQUIP. & FIXTURES
ONLY. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL REQUIREMENTS.
3. THIS ELECTRICAL PLAN IS INTENDED TO SHOW OUTLET TYPES, LOCATIONS, &
CONNECTION POSITIONS & LOADS.
4. ELECTRICAL WORK FOR FABRICATED FOOD SERVICE EQUIP. & FIXTURES, SHALL BE
COMPLETELY PRE-WIRED TO A JUNCTION-BOX MOUNTED ON THE EQUIPMENT, IN AN
ACCESSIBLE POSITION. FINAL CONNECTIONS TO THE FOOD SERVICE FIXTURES & EQUIP.
JUNCTION BOXES OR PULL BOXES, & ELECTRICAL WORK FROM PANEL BOXES SHALL BE
BY CONTRACTOR.
5. FINAL CONNECTIONS TO FOOD SERVICE EQUIP. & FIXTURES SHALL BE BY THE
CONTRACTOR, INCLUDING LABOR & MATERIALS.
6. CONTRACTOR SHALL FURNISH & INSTALL THE FOLLOWING:
A. JUNCTION BOXES, ELECTRICAL OUTLETS, COVER PLATES, SWITCHES, NOT BUILT INTO
THE EQUIP. & FIXTURES. OUTLETS, JUNCTION BOXES, & COVER PLATES.
B. SHUNT TRIP CIRCUIT BREAKERS OR DISCONNECTS FOR FIRE PROTECTION SYSTEM,
SHUT-OFF OF FOOD SERVICE EQUIP. ELECTRICAL CIRCUITS LOCATED BENEATH
EXHAUST HOODS AS REQUIRED BY N.F.P.A. & APPLICABLE CODES.
7. CONTRACTOR SHALL PROVIDE CIRCUIT(S) CONDUIT & WIRING, INST ELECTRICAL
COMPONENTS & INTERWIRE BETWEEN THE FOLLOWING:
A. REMOTE REFRIGERATION EQUIP. & EVAPORATOR COILS. INCLUDING NECESSARY
LIGHTS, ALARMS, HEATERS AND SWITCHES.
B. CONTROL PANELS TO WATER WASH EXHAUST HOODS & EXHAUST/SUPPLY FAN
MAGNETIC STARTERS PER MANUFACTURERS INSTRUCTION.
C. FOOD SERVICE EXHAUST HOODS TO FIRE PROTECTION SYSTEM & SHUT-OFFS.
D. FOOD SERVICE EXHAUST HOOD LIGHTS & SWITCHES.
EQUIPMENT LAYOUTS AND ROUGH-INS
EQUIPMENT NUMBER DESIGNATOR . SEE
EQUIPMENT LIST ON SAME SHEET OR
UTILITY SCHEDULE ON SHEET QF600.
XX
43 50
56 62
78 80
71A
49A
28 42A
126A
DRY STORAGE
MEAT/FISH
COOLER
PRODUCE
COOLER
BREAK-
DOWN
CONDIMENTS
GENERAL
FREEZER
INGRED.
STORAGE
JANITOR/CLEANING
SUPPLIES
WAREHOUSE
COLD KITCHEN
DRY
STOR.
FOOD BANK
COOLER
WAREWASH
ELEV.
SUPERVISOR'S OFFICE
NOURISHMENT PREPNOURISHMENT
COOLER
DIET.OFFICE
COLD COLD
80 GAL. KETTLES
PREPPREP
JAN.
PATRIENT TRAY
ASSEMBLY
CART STAGING
COOK COOK
CLEAN
STAGING
SOILED
STAGING
BREAK
DOWN
CART WASH
BEV.
HOT GRAB-N-GO
HOT FOOD
DELI
DISH DROP
TILT SKILLETSCOMBI OVENS
LOCKERS/RESTROOM
CHIEF
OFFICE
LOCKERS/RESTROOM
AO
OFFICE
HEALTHY/DEMO
KITCHEN
NEW SERVICE COORIDOR
OUTDOOR
REFRIGERATION RACK -
TO BE LOCATED
F1
QF111
F1A
QF111
F2
QF121
F3
QF131
F4
QF141
F5
QF151
F6
QF161
F8
QF181
F7
QF171
RESTRM. RESTRM.
PATRIOT
STORAGE
SUPERVISOR'S
OFFICE
SUPERVISOR'S
OFFICE
PATIENT/DOM DINING
DAIRY COOLER
R/ F
R
R
CONV./STEAM
DISH WASH
SHORT
ORDER
COLD
GRAB-
N-GO
SOILED
BREAK
DOWN
R
H
F
COOK
TUG
CHARGING
SODA/ICE
COFFEE
CONDIMENT
INDUCTION
GRIDDLE
RETHERM
STATIONS
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:1
P
M
QF100
OVERALL FOODSERVICE
EQUIPMENT PLAN
CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 2 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
32'16'8'4'2'0'
1/8" = 1'-0"
FOODSERVICE OVERALL PLAN
F1
31 43 50
5649A42A
12 12
3 16
DRY STORAGE
MEAT/FISH
COOLER
PRODUCE
COOLER
BREAKDOWN
CONDIMENTS
GENERAL
FREEZER
INGREDIENT
STORAGE
JANITOR/CLEANING
SUPPLIES
WAREHOUSE
DAIRY COOLER
2323 23 23
13 13
49A
OUTDOOR REFRIGERATION
RACK - VERIFY LOCATION
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:1
P
M
QF111
FOOD SERVICE EQUIPMENT PLAN CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 3 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
FOODSERVICE EQUIPMENT SCHEDULE
ITEM NO QTY ACQ/INS* NAME EQUIPMENT REMARKS
1 1 VC HIGH-DENSITY SHELVING TOP-MOUNT STYLE
2 6 VV PALLET BY VENDOR
3 1 CC MEAT/FISH COOLER
4 1 CC EVAPORATOR COIL MEAT/FISH COOLER
5 - SPARE NUMBER
6 6 VC SHELVING UNIT
7 6 VV PALLET BY VENDOR
8 - SPARE NUMBER
9 - SPARE NUMBER
10 - SPARE NUMBER
11 1 CC PRODUCE COOLER
12 2 CC EVAPORATOR COIL PRODUCE COOLER
13 13 VC SHELVING UNIT
14 1 CC DAIRY COOLER
15 - SPARE NUMBER
16 1 CC BREAKDOWN COOLER
17 1 CC EVAPORATOR COIL BREAKDOWN COOLER
18 - SPARE NUMBER
19 - SPARE NUMBER
20 - SPARE NUMBER
21 1 CC CONDIMENT COOLER
22 1 CC EVAPORATOR COIL CONDIMENT COOLER
23 4 VC SHELVING UNIT
24 - SPARE NUMBER
25 - SPARE NUMBER
26 1 CC GENERAL FREEZER
27 2 CC EVAPORATOR COIL GENERAL FREEZER
28 11 CC SHELVING UNIT
29 - SPARE NUMBER
30 - SPARE NUMBER
31 4 VV PALLET BY VENDOR
32 1 VC HIGH-DENSITY SHELVING TOP-MOUNT STYLE
33 5 VC SHELVING UNIT
34 1 CC REFRIGERATION SYSTEM
35-100 - SPARE NUMBER
16'8'4'2'1'0'
1/4" = 1'-0"
FOOD SERVICE EQUIPMENT PLAN - STORAGE AREAS
F1
16'8'4'2'1'0'
1/4" = 1'-0"
FOODSERVICE EQUIPMENT PLAN - REFRIGERATION RACK
B7
*ACQUIRED/INSTALLED
CC: CONTRACTOR PROVIDED CONTRACTOR INSTALLED
VC: VA PROVIDED/CONTRACTOR INSTALLED
VV: VA PROVIDED/VA INSTALLED
1. SEE SHEET QF600 FOR UTILITY INFORMATION.
2. CONTRACTOR RESPONSIBLE FOR EQUIPMENT LEAD TIMES BASED ON
INSTALLATION SCHEDULE AND PHASING.
EQUIPMENT NUMBER DESIGNATOR . SEE
EQUIPMENT LIST ON SAME SHEET OR
CONCRETE SLAB
2" GROUT FILL
(BY G.C.)
SECURE WITH RAMSET OR
SIMILAR (BY F.E.C.)
SHIM AS NEEDED
TO LEVEL
TEK SCREW
2" URETHANE
INSULATION
(BY F.E.C.)
2" URETHANE
INSULATION
(BY F.E.C.)
REINFORCED CONCRETE FLOOR
AND COVERING (BY G.C.)
5000 PSI CONCRETE W/4x4 #10
WELDED WIRE
WALK-IN COOLER /FREEZER FLOOR DEPRESSION
AT OUTSIDE WALL
CONCRETE SLAB
2" GROUT FILL
(BY G.C.)
SECURE WITH RAMSET OR
SIMILAR (BY F.E.C.)
SHIM AS NEEDED
TO LEVEL
TEK SCREW
2" URETHANE
INSULATION
(BY F.E.C.)
2" URETHANE
INSULATION
(BY F.E.C.)
REINFORCED CONCRETE FLOOR
AND COVERING (BY G.C.)
5000 PSI CONCRETE W/4x4 #10
WELDED WIRE
TRESHOLD SET FLUSH
WITH ADJACENT FLOORS
WALK-IN BOX DOOR
SWEEP
WALK-IN BOX PANEL
CONCRETE SLAB
SECURE WITH RAMSET OR
SIMILAR (BY F.E.C.)
STEEL CHANNEL
SHIM AS NEEDED
TO LEVEL
TEK SCREW
2" URETHANE
INSULATION
(BY F.E.C.)
2" URETHANE
INSULATION
(BY F.E.C.)
REINFORCED CONCRETE FLOOR
AND COVERING (BY G.C.)
5000 PSI CONCRETE W/4x4 #10
WELDED WIRE
WALK-IN BOX PANEL
STEEL CHANNEL
STEEL CHANNEL
WALK-IN COOLER /FREEZER FLOOR DEPRESSION
AT DOOR
WALK-IN COOLER /FREEZER FLOOR DEPRESSION
AT CENTER WALL
F.E.C. = FOODSERVICE EQUIPMENT
CONTRACTOR
G.C. = GENERAL CONTRACTOR
F.E.C. = FOODSERVICE EQUIPMENT
CONTRACTOR
G.C. = GENERAL CONTRACTOR
F.E.C. = FOODSERVICE EQUIPMENT
CONTRACTOR
G.C. = GENERAL CONTRACTOR
RESINOUS FLOORING W/
COVE BASE AT WALK-IN
INTERIOR BY FLOORING
CONTRACTOR (SEE
ARCHITECT'S SPECS)
RESINOUS FLOORING BY
FLOORING CONTRACTOR
(SEE ARCHITECT'S SPECS)
RESINOUS FLOORING W/
COVE BASE AT WALK-IN
INTERIOR BY FLOORING
CONTRACTOR (SEE
ARCHITECT'S SPECS)
C1
C2
C2
4"
4"
4"
8"
8"
8"
31 43 50
5649A42A
C1
B
B
DRY STORAGE
B
B
B
PROVIDE CLEAN LEVEL
SURFACE FOR INSTALLATION OF
OF WALK-IN ON TOP OF SLAB
C2
C1
C3
C2
C2
C3
C2
C1
C3
C3
C1
C1
RAISED FLOOR AREA. FIELD
VERIFY CONDITIONS AND
REQUIREMENTS FOR FLOOR
INSULATION.
49A
OUTDOOR REFRIGERATION
RACK - VERIFY LOCATION
PROVIDE CLEAN LEVEL SURFACE FOR
INSTALLATIONOF COMPRESSOR RACK
WITH ADEQUATE CLEARANCES
AROUND UNIT
UNIT WEIGHT: 4650 LB.
3"
3"
3"
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:1
P
M
QF112
BUILDING CONDITIONS &
VENTILATION PLAN
CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 4 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
BUILDING CONDITIONS & VENT. PLAN - STORAGE AREAS
F1
16'8'4'2'1'0'
1/4" = 1'-0"
BUILDING CONDITONS & VENT. PLAN - REFRIGERATION RACK
B7
REFER TO FOOD SERVICE SHEETS QF601 & QF602 FOR UTILITY INFORMATION
KITCHEN BUILDING CONDITIONS & VENTILATION NOTES
1. KITCHEN AREAS INCLUDING KITCHEN STORAGE WALK-INS, PREP AREAS, COOKING
AREAS, AND WARE WASH REQUIRES STRUCTURAL FLOOR TO SAFELY HANDLE HEAVY
FOODSERVICE EQUIPMENT PER BUILDING CODE.
2. ROUGH-IN/CONNECTION HEIGHTS NOTED ON THE MECHANICAL CONNECTION SCHEDULE
INDICATE HEIGHT ABOVE FINISHED FLOOR (AFF)
3. ASSURE THE FOLLOWING AMONGST THE TRADES:
A. IN-WALL REINFORCING OR BACKING AS REQUIRED FOR WALL MOUNTED KITCHEN
EQUIPMENT, COORDINATE SIZE, MOUNTING HEIGHTS AND INSTALLATION
REQUIREMENTS WITH CONTRACTOR MOUNT SHELVES AT 54" AND 66" -A.F.F.,
UNLESS OTHERWISE NOTED.
B. FOR WALKS IN COOLERS/FREEZERS PROVIDE SMOOTH AND LEVEL FLOOR
SURFACE.
C. PROVIDE FIRE-RATED MATERIALS AND/OR INSULATION FOR EXHAUST DUCTS, VENT
STACKS, PORTION OF EXHAUST HOODS ABOVE CEILING HEIGHT, HEAT PRODUCING
EQUIPMENT, ROOF/WALL PENETRATIONS.
4. MOUNT STAINLESS STEEL CORNER GUARDS ON EXTERNAL CORNERS OF INTERIOR
WALLS, PARTITIONS AND COLUMNS AS SHOW IN ARCHITECTURAL PLANS.
3" X 3" X 60" HIGH 16 GA. S/S CORNER GUARDS, BY F.E.C.B
C1 PROVIDE 8" DEPRESSION FOR WALK-IN FLOORS - SEE
DETAIL ON THIS SHEET. COORDINATE EXISTING
STRUCTURE AND CONDITIONS.
C2 PROVIDE 8" DEPRESSION FOR WALK-IN FLOORS UNDER
COOLER/FREEZER DOORS - SEE DETAIL ON THIS SHEET.
C3 PROVIDE 8" DEPRESSION FOR WALK-IN FLOORS UNDER
ADJOINGING WALLS - SEE DETAIL ON THIS SHEET.
31 43 50
5649A42A
F.S.
F.S.
F.S.
12 12
F.S.
49A
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:1
P
M
QF113
PLUMBING ROUGH-IN PLAN CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 5 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
PLUMBING PLAN - STORAGE AREAS
F1
16'8'4'2'1'0'
1/4" = 1'-0"
PLUMBING PLAN - REFRIGERATION RACK
B7
REFER TO FOOD SERVICE SHEETS QF601 & QF602 FOR UTILITY INFORMATION
PLUMBING ROUGH-IN PLANS:
1. ROUGH-INS & CONNECTIONS SHOWN RELATE TO FOOD SERVICE EQUIPMENT ONLY.
PLUMBING DRAWINGS FOR ADDITIONAL REQUIREMENTS.
2. THIS PLUMBING PLAN IS INTENDED TO SHOW PRELIMINARY ROUGH-IN LOCATIONS &
HEIGHTS, CONNECTION SIZES & LOAD REQUIREMENTS.
3. FINAL CONNECTIONS TO FOOD SERVICE EQUIP. SHALL BE BY THE CONTRACTOR,
INCLUDING REQUIRED MATERIALS, SUCH AS STOPS, VALVES, FILTERS, TRAPS, CHECK
VALVES, PIPING, TUBING, ETC. UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
FURNISH BRASS BALL VALVE STOPS TO H/C WATER CONNECTIONS IN ACCORD WITH SIZE
OF FEED PIPE.
4. CONTRACTOR SHALL FURNISH & INSTALL THE FOLLOWING:
A. WATER, WASTE, GAS, STEAM, & AIR SERVICE FROM THE POINT OF ROUGH-IN TO
THE FOOD SERVICE FIXTURE & EQUIP. ITEMS AS SHOWN ON THE PLAN. ROUGH-IN
OUTLETS TO STUB 2" OUT OF WALLS AT HEIGHT INDICATED TO CENTERLINE OF
OUTLET. FLOOR ROUGH-INS TO STUB UP 4" (100 mm) A.F.F. OR CURB. FLOOR
OPENINGS &/OR PENETRATIONS SHALL BE WATER TIGHT & FIRE CAULKED .
B. FLOOR SINKS, COMPLETE GRATES, UNLESS OTHERWISE NOTED, & REMOVABLE
SEDIMENT BUCKETS SET FLUSH WITH FINISHED FLOOR, UNLESS OTHERWISE NOTED
OR REQUIRED BY CODE.
C. WASTE LINES, DIRECT & INDIRECT, EXCEPT AS NOTED OTHERWISE. MINIMUM
DIAMETER OF LINES SHALL BE AS NOTED IN THE PLUMBING CONNECTION
SCHEDULE, REGARDLESS OF CONNECTION SIZE, & SHALL BE PITCHED DOWNWARD.
MAINTAIN DRAINS AS HIGH AS POSSIBLE ABOVE FLOOR. PROVIDE CLEAN-OUTS ON
WASTE LINES.
D. INDIRECT WASTE LINES FOR WALK-IN REFRIGERATED BOXES SHALL BE
PITCHED A MINIMUM OF 1/4" PER FOOT WITH A "P" TRAP AT END OVER FLOOR SINK.
PIPING ON EXTERIOR SHALL BE PARALLEL TO WALK-IN. PENETRATE WALK-IN WALL
WITH WASTE LINE AT 1'-0" (300 mm) A.F.F.
E. INSTALL FIRE PROTECTION SYSTEM GAS SHUT-OFF VALVE(S), FURNISHED BY
THE CONTRACTOR, WHEN GAS COOKING EQUIP. IS USED.
EQUIPMENT NUMBER DESIGNATOR . SEE
EQUIPMENT LIST ON SAME SHEET OR
31 43 50
5649A42A
3 16 21
3A 16A
26A
16A
A B
49A
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:2
P
M
QF114
ELECTRICAL ROUGH-IN PLAN CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 6 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
ELECTRICAL PLAN - SORAGE AREAS
F1
16'8'4'2'1'0'
1/4" = 1'-0"
ELECTRICAL PLAN - REFRIGERATION RACK
B7
REFER TO FOOD SERVICE SHEETS QF601 & QF602 FOR UTILITY INFORMATION
ELECTRICAL ROUGH-IN PLAN:
1. ELECTRICAL SYSTEM IS DESIGNED FOR 120/208 VOLTS, 3 PHASE, 4 WIRE, 60 HERTZ,
UNLESS OTHERWISE NOTED.
2. OUTLETS & CONNECTIONS SHOWN RELATE TO FOOD SERVICE EQUIP. & FIXTURES
ONLY. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL REQUIREMENTS.
3. THIS ELECTRICAL PLAN IS INTENDED TO SHOW OUTLET TYPES, LOCATIONS, &
CONNECTION POSITIONS & LOADS.
4. ELECTRICAL WORK FOR FABRICATED FOOD SERVICE EQUIP. & FIXTURES, SHALL BE
COMPLETELY PRE-WIRED TO A JUNCTION-BOX MOUNTED ON THE EQUIPMENT, IN AN
ACCESSIBLE POSITION. FINAL CONNECTIONS TO THE FOOD SERVICE FIXTURES & EQUIP.
JUNCTION BOXES OR PULL BOXES, & ELECTRICAL WORK FROM PANEL BOXES SHALL BE
BY CONTRACTOR.
5. FINAL CONNECTIONS TO FOOD SERVICE EQUIP. & FIXTURES SHALL BE BY THE
CONTRACTOR, INCLUDING LABOR & MATERIALS.
6. CONTRACTOR SHALL FURNISH & INSTALL THE FOLLOWING:
A. JUNCTION BOXES, ELECTRICAL OUTLETS, COVER PLATES, SWITCHES, NOT BUILT INTO
THE EQUIP. & FIXTURES. OUTLETS, JUNCTION BOXES, & COVER PLATES.
B. SHUNT TRIP CIRCUIT BREAKERS OR DISCONNECTS FOR FIRE PROTECTION SYSTEM,
SHUT-OFF OF FOOD SERVICE EQUIP. ELECTRICAL CIRCUITS LOCATED BENEATH
EXHAUST HOODS AS REQUIRED BY N.F.P.A. & APPLICABLE CODES.
7. CONTRACTOR SHALL PROVIDE CIRCUIT(S) CONDUIT & WIRING, INST ELECTRICAL
COMPONENTS & INTERWIRE BETWEEN THE FOLLOWING:
A. REMOTE REFRIGERATION EQUIP. & EVAPORATOR COILS. INCLUDING NECESSARY
LIGHTS, ALARMS, HEATERS AND SWITCHES.
B. CONTROL PANELS TO WATER WASH EXHAUST HOODS & EXHAUST/SUPPLY FAN
MAGNETIC STARTERS PER MANUFACTURERS INSTRUCTION.
C. FOOD SERVICE EXHAUST HOODS TO FIRE PROTECTION SYSTEM & SHUT-OFFS.
D. FOOD SERVICE EXHAUST HOOD LIGHTS & SWITCHES.
EQUIPMENT NUMBER DESIGNATOR . SEE
EQUIPMENT LIST ON SAME SHEET OR
56 62
103107 107
143 143
COLD KITCHEN
DRY
STORAGE
FOOD BANK COOLER
WARE WASH
136 136 136
133 132
CEILING MOUNT
CEILING MOUNT
CEILING MOUNT
143143
143143
143143
143143
143143
143143143143
143 143
145145
144 144
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:2
P
M
QF121
FOOD SERVICE EQUIPMENT PLAN CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 7 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
FOOD SERVICE EQUIPMENT PLAN - PREP & DISHWASH AREAS
E2
FOODSERVICE EQUIPMENT SCHEDULE
ITEM NO QTY ACQ/INS* NAME EQUIPMENT REMARKS
101 4 VC SHELVING UNIT
102 1 CC HAND SINK
103 1 VC 20-QUART MIXER
104 1 CC PREP TABLE W/SINKS
105 - SPARE NUMBER
106 3 CC EVAPORATOR COIL PRODUCE COOLER
107 2 VC FOOD PROCESSOR
108 1 VC MOBILE WORK TABLE
109 - SPARE NUMBER
110 - SPARE NUMBER
111 1 VC MOBILE WORK TABLE
112 2 VC UTILITY RACK
113 - SPARE NUMBER
114 1 VC MOBILE WORK TABLE
115 - SPARE NUMBER
116 1 CC HAND SINK
117 1 CC PREP TABLE W/SINKS
118 - SPARE NUMBER
119 - SPARE NUMBER
120 - SPARE NUMBER
121 - SPARE NUMBER
122 1 CC HAND SINK
123 - SPARE NUMBER
124 1 CC DISPOSER
125 - SPARE NUMBER
126 - SPARE NUMBER
127 1 CC SCRAPPING TABLE
128 1 CC 3-COMPARTMENT SINK
129 - SPARE NUMBER
130 - SPARE NUMBER
131 - SPARE NUMBER
132 1 CC FLIGHT-TYPE DISH MACHINE ELECTRIC BOOSTER HEATER
132B 1 ELECTRIC BOOSTER HEATER
133 1 CC VENT DUCT - UNLOAD END UNLOAD END
134 1 CC VENT DUCT - LOAD END LOAD END
135 - SPARE NUMBER
136 4 VC POT/PAN DRYING RACK
137 1 CC HAND SINK
138 - SPARE NUMBER
139 - SPARE NUMBER
140 - SPARE NUMBER
141 1 CC FOOD BANK COOLER
142 1 CC EVAPORATOR COIL FOOD BANK COOLER
143 22 VC UTILITY RACK
144 2 CC BLAST CHILLER COMPARTMENT
145 2 CC BLAST CHILLER COIL
145-200 - SPARE NUMBER
*ACQUIRED/INSTALLED
CC: CONTRACTOR PROVIDED CONTRACTOR INSTALLED
VC: VA PROVIDED/CONTRACTOR INSTALLED
VV: VA PROVIDED/VA INSTALLED
1. SEE SHEET QF600 FOR UTILITY INFORMATION.
2. CONTRACTOR RESPONSIBLE FOR EQUIPMENT LEAD TIMES BASED ON
INSTALLATION SCHEDULE AND PHASING.
EQUIPMENT NUMBER DESIGNATOR . SEE
EQUIPMENT LIST ON SAME SHEET OR
56 62
B
B
B
B
BB
B
B
134 133
B
A
B
A
A
A
B B
B B
G
G
G
PROVIDE CLEAN LEVEL
SURFACE FOR INSTALLATION OF
OF WALK-IN ON TOP OF SLAB
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:2
P
M
QF122
BUILDING CONDITIONS @
VENTILATION PLAN
CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 8 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
BUILDING CONDITIONS & VENT. PLAN - PREP & DISH WASH AREAS
E2
KITCHEN BUILDING CONDITIONS & VENTILATION :
1. ALL WORK INDICATED ON THIS PLAN AND IN THESE NOTES ARE TO BE BY OTHERS THAN
THE FOODSERVICE EQUIPMENT CONTRACTOR (F.E.C.) UNLESS NOTED.
2. WALLS, FLOORS, AND CEILINGS IN KITCHEN, PREPARATION, SERVICE, AND
WAREWASHING AREAS OR ANY OTHER LOCATION WHERE FOOD AND/OR BEVERAGES ARE
PREPARED, MUST BE SMOOTH, EASILY CLEANABLE, NON - ABSORBENT, AND DURABLE.
WALLS AND CEILINGS ARE TO BE LIGHT COLORED.
3. FINAL DUCT CONNECTIONS ARE BY MECHANICAL CONTRACTOR.
4. ROUGH-IN/CONNECTION HEIGHTS NOTED ON THE MECHANICAL CONNECTION SCHEDULE
INDICATE HEIGHT ABOVE FINISHED FLOOR (A.F.F.)
5. ASSURE THE FOLLOWING AMONGST THE TRADES:
A. IN-WALL REINFORCING OR BACKING AS REQUIRED FOR WALL MOUNTED KITCHEN
EQUIPMENT, COORDINATE SIZE, MOUNTING HEIGHTS AND INSTALLATION
REQUIREMENTS WITH F.E.C. MOUNT ALL SHELVES AT 54" AND 66" -A.F.F., UNLESS
OTHERWISE NOTED.
B. SLOPE FLOORS TO FLOOR DRAINS, AND FLOOR TROUGHS.
C. PROVIDE DOOR/WALL OPENINGS AND/OR PASSAGES TO ASSURE ACCESS FOR ALL
KITCHEN EQUIPMENT.
D. PROVIDE WALK-IN REFRIGERATION DEPRESSIONS, SMOOTH AND TRANSIT - LEVEL,
WHERE DEPRESSIONS ARE REQUIRED. DEPTH AS NOTED. COORDINATE
REQUIREMENTS WITH F.E.C.
E. FILL EXCESS DEPRESSIONS AROUND WALK-INS, FLOOR TROUGHS, WITH GROUT,
FINISHED FLOOR, AND MATCHING COVED BASE AFTER WALK-INS AND FLOOR
TROUGHS HAVE BEEN INSTALLED BY F.E.C.
F. PROVIDE MASONRY PADS, WHEN SHOWN, WITH TROWEL - SMOOTH AND LEVEL
FINISH.
H. PROVIDE FIRE-RATED MATERIALS AND/OR INSULATION AS REQUIRED FOR EXHAUST
DUCTS, VENT STACKS, PORTION OF EXHAUST HOODS ABOVE CEILING HEIGHT, HEAT
PRODUCING EQUIPMENT, ROOF/WALL PENETRATIONS, ETC.; PER LOCAL CODES.
I. PROVIDE COVED BASE MOLDING OR COVED INTEGRAL FLOOR MATERIALS AS
REQUIRED AT ALL VERTICAL SURFACES WHERE THEY MEET FLOORS IN
FOODSERVICE AREAS.
WALL BACKING - BY G.C. VERIFY SIZE & LOCATION WITH F.E.C.A
REFER TO FOOD SERVICE SHEETS QF601 & QF602 FOR UTILITY INFORMATION
3" X 3" X 60" HIGH 16 GA. S/S CORNER GUARDS, BY F.E.C.B
GENERAL CONTRACTOR TO PROVIDE STRUCTURAL
SUPPORT ABOVE FOR CEILING HUNG EQUIPMENT -
F.E.C. TO COORDINATE LOCATION,
G
56 62
F.S.
117117
116116116
F.S. 142
104104 102102102
F.S.
F.S.
F.S.
122122
137137137
OVERHEAD
EVAPORATOR
COIL DRAIN
OVERHEAD
EVAPORATOR
COIL DRAIN
OVERHEAD
EVAPORATOR
COIL DRAIN
132132 132
UTILITY CW
CONNECTION
127127
127127
128128128
F.S.
145145
F.S.
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:2
P
M
QF123
PLUMBING ROUGH-IN PLAN CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 9 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
PLUMBING PLAN - PREP & DISH WASH AREAS
E2
REFER TO FOOD SERVICE SHEETS QF601 & QF602 FOR UTILITY INFORMATION
PLUMBING ROUGH-IN PLANS:
1. ROUGH-INS & CONNECTIONS SHOWN RELATE TO FOOD SERVICE EQUIPMENT ONLY.
PLUMBING DRAWINGS FOR ADDITIONAL REQUIREMENTS.
2. THIS PLUMBING PLAN IS INTENDED TO SHOW PRELIMINARY ROUGH-IN LOCATIONS &
HEIGHTS, CONNECTION SIZES & LOAD REQUIREMENTS.
3. FINAL CONNECTIONS TO FOOD SERVICE EQUIP. SHALL BE BY THE CONTRACTOR,
INCLUDING REQUIRED MATERIALS, SUCH AS STOPS, VALVES, FILTERS, TRAPS, CHECK
VALVES, PIPING, TUBING, ETC. UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
FURNISH BRASS BALL VALVE STOPS TO H/C WATER CONNECTIONS IN ACCORD WITH SIZE
OF FEED PIPE.
4. CONTRACTOR SHALL FURNISH & INSTALL THE FOLLOWING:
A. WATER, WASTE, GAS, STEAM, & AIR SERVICE FROM THE POINT OF ROUGH-IN TO
THE FOOD SERVICE FIXTURE & EQUIP. ITEMS AS SHOWN ON THE PLAN. ROUGH-IN
OUTLETS TO STUB 2" OUT OF WALLS AT HEIGHT INDICATED TO CENTERLINE OF
OUTLET. FLOOR ROUGH-INS TO STUB UP 4" (100 mm) A.F.F. OR CURB. FLOOR
OPENINGS &/OR PENETRATIONS SHALL BE WATER TIGHT & FIRE CAULKED .
B. FLOOR SINKS, COMPLETE GRATES, UNLESS OTHERWISE NOTED, & REMOVABLE
SEDIMENT BUCKETS SET FLUSH WITH FINISHED FLOOR, UNLESS OTHERWISE NOTED
OR REQUIRED BY CODE.
C. WASTE LINES, DIRECT & INDIRECT, EXCEPT AS NOTED OTHERWISE. MINIMUM
DIAMETER OF LINES SHALL BE AS NOTED IN THE PLUMBING CONNECTION
SCHEDULE, REGARDLESS OF CONNECTION SIZE, & SHALL BE PITCHED DOWNWARD.
MAINTAIN DRAINS AS HIGH AS POSSIBLE ABOVE FLOOR. PROVIDE CLEAN-OUTS ON
WASTE LINES.
D. INDIRECT WASTE LINES FOR WALK-IN REFRIGERATED BOXES SHALL BE
PITCHED A MINIMUM OF 1/4" PER FOOT WITH A "P" TRAP AT END OVER FLOOR SINK.
PIPING ON EXTERIOR SHALL BE PARALLEL TO WALK-IN. PENETRATE WALK-IN WALL
WITH WASTE LINE AT 1'-0" (300 mm) A.F.F.
E. INSTALL FIRE PROTECTION SYSTEM GAS SHUT-OFF VALVE(S), FURNISHED BY
THE CONTRACTOR, WHEN GAS COOKING EQUIP. IS USED.
EQUIPMENT NUMBER DESIGNATOR . SEE
EQUIPMENT LIST ON SAME SHEET OR
56 62
103107107 104104
132B
145145
141A
141A
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:2
P
M
QF124
ELECTRICAL ROUGH-IN PLAN CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 10 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
ELECTRICAL PLAN - PREP & DISH WASH AREAS
E2
REFER TO FOOD SERVICE SHEETS QF601 & QF602 FOR UTILITY INFORMATION
ELECTRICAL ROUGH-IN PLAN:
1. ELECTRICAL SYSTEM IS DESIGNED FOR 120/208 VOLTS, 3 PHASE, 4 WIRE, 60 HERTZ,
UNLESS OTHERWISE NOTED.
2. OUTLETS & CONNECTIONS SHOWN RELATE TO FOOD SERVICE EQUIP. & FIXTURES
ONLY. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL REQUIREMENTS.
3. THIS ELECTRICAL PLAN IS INTENDED TO SHOW OUTLET TYPES, LOCATIONS, &
CONNECTION POSITIONS & LOADS.
4. ELECTRICAL WORK FOR FABRICATED FOOD SERVICE EQUIP. & FIXTURES, SHALL BE
COMPLETELY PRE-WIRED TO A JUNCTION-BOX MOUNTED ON THE EQUIPMENT, IN AN
ACCESSIBLE POSITION. FINAL CONNECTIONS TO THE FOOD SERVICE FIXTURES & EQUIP.
JUNCTION BOXES OR PULL BOXES, & ELECTRICAL WORK FROM PANEL BOXES SHALL BE
BY CONTRACTOR.
5. FINAL CONNECTIONS TO FOOD SERVICE EQUIP. & FIXTURES SHALL BE BY THE
CONTRACTOR, INCLUDING LABOR & MATERIALS.
6. CONTRACTOR SHALL FURNISH & INSTALL THE FOLLOWING:
A. JUNCTION BOXES, ELECTRICAL OUTLETS, COVER PLATES, SWITCHES, NOT BUILT INTO
THE EQUIP. & FIXTURES. OUTLETS, JUNCTION BOXES, & COVER PLATES.
B. SHUNT TRIP CIRCUIT BREAKERS OR DISCONNECTS FOR FIRE PROTECTION SYSTEM,
SHUT-OFF OF FOOD SERVICE EQUIP. ELECTRICAL CIRCUITS LOCATED BENEATH
EXHAUST HOODS AS REQUIRED BY N.F.P.A. & APPLICABLE CODES.
7. CONTRACTOR SHALL PROVIDE CIRCUIT(S) CONDUIT & WIRING, INST ELECTRICAL
COMPONENTS & INTERWIRE BETWEEN THE FOLLOWING:
A. REMOTE REFRIGERATION EQUIP. & EVAPORATOR COILS. INCLUDING NECESSARY
LIGHTS, ALARMS, HEATERS AND SWITCHES.
B. CONTROL PANELS TO WATER WASH EXHAUST HOODS & EXHAUST/SUPPLY FAN
MAGNETIC STARTERS PER MANUFACTURERS INSTRUCTION.
C. FOOD SERVICE EXHAUST HOODS TO FIRE PROTECTION SYSTEM & SHUT-OFFS.
D. FOOD SERVICE EXHAUST HOOD LIGHTS & SWITCHES.
EQUIPMENT NUMBER DESIGNATOR . SEE
EQUIPMENT LIST ON SAME SHEET OR
57 63
216 216 216 216 216 216
213 213 213 213
206 208
DIET OFFICE
NOURISHMENT PREPNOURISHMENT COOLER
OFFICE
204 204204
203 203
203203
TUG CHARGING
211 211 211 211
211211211211211211211211
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:2
P
M
QF131
FOOD SERVICE EQUIPMENT PLAN CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 11 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
FOOD SERVICE EQUIPMENT PLAN - PREP AREA
D2
FOODSERVICE EQUIPMENT SCHEDULE
ITEM NO QTY ACQ/INS* NAME EQUIPMENT REMARKS
201 1 CC NOURISHMENT COOLER
202 1 CC EVAPORATOR COIL - NOURISHMENT COOLER PRODUCE COOLER
203 5 VC SHELVING UNIT
204 3 VV TUG EISTING PROVIDED BY VA
205 - SPARE NUMBER
206 1 CC HAND SINK
207 1 CC PREP TABLE W/SINKS
208 1 CC HAND SINK
209 - SPARE NUMBER
210 - SPARE NUMBER
211 12 VC UTILITY RACK
212 1 VC WORK TABLE
213 4 VC ROLL-IN REFRIGERATOR
214 - SPARE NUMBER
215 - SPARE NUMBER
216 6 VC SHELVING UNIT
217-300 - SPARE NUMBER
*ACQUIRED/INSTALLED
CC: CONTRACTOR PROVIDED CONTRACTOR INSTALLED
VC: VA PROVIDED/CONTRACTOR INSTALLED
VV: VA PROVIDED/VA INSTALLED
1. SEE SHEET QF600 FOR UTILITY INFORMATION.
2. CONTRACTOR RESPONSIBLE FOR EQUIPMENT LEAD TIMES BASED ON
INSTALLATION SCHEDULE AND PHASING.
EQUIPMENT NUMBER DESIGNATOR . SEE
EQUIPMENT LIST ON SAME SHEET OR
57 63
B
A
B
B
A
PROVIDE CLEAN LEVEL
SURFACE FOR INSTALLATION
OF OF WALK-IN ON TOP OF
SLAB
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:2
P
M
QF132
BUILDING CONDITIONS @
VENTILATION PLAN
CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 12 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
BUILDING CONDITIONS & VENT. PLAN - PREP AREA
D2
KITCHEN BUILDING CONDITIONS & VENTILATION :
1. ALL WORK INDICATED ON THIS PLAN AND IN THESE NOTES ARE TO BE BY OTHERS THAN
THE FOODSERVICE EQUIPMENT CONTRACTOR (F.E.C.) UNLESS NOTED.
2. WALLS, FLOORS, AND CEILINGS IN KITCHEN, PREPARATION, SERVICE, AND
WAREWASHING AREAS OR ANY OTHER LOCATION WHERE FOOD AND/OR BEVERAGES ARE
PREPARED, MUST BE SMOOTH, EASILY CLEANABLE, NON - ABSORBENT, AND DURABLE.
WALLS AND CEILINGS ARE TO BE LIGHT COLORED.
3. FINAL DUCT CONNECTIONS ARE BY MECHANICAL CONTRACTOR.
4. ROUGH-IN/CONNECTION HEIGHTS NOTED ON THE MECHANICAL CONNECTION SCHEDULE
INDICATE HEIGHT ABOVE FINISHED FLOOR (A.F.F.)
5. ASSURE THE FOLLOWING AMONGST THE TRADES:
A. IN-WALL REINFORCING OR BACKING AS REQUIRED FOR WALL MOUNTED KITCHEN
EQUIPMENT, COORDINATE SIZE, MOUNTING HEIGHTS AND INSTALLATION
REQUIREMENTS WITH F.E.C. MOUNT ALL SHELVES AT 54" AND 66" -A.F.F., UNLESS
OTHERWISE NOTED.
B. SLOPE FLOORS TO FLOOR DRAINS, AND FLOOR TROUGHS.
C. PROVIDE DOOR/WALL OPENINGS AND/OR PASSAGES TO ASSURE ACCESS FOR ALL
KITCHEN EQUIPMENT.
D. PROVIDE WALK-IN REFRIGERATION DEPRESSIONS, SMOOTH AND TRANSIT - LEVEL,
WHERE DEPRESSIONS ARE REQUIRED. DEPTH AS NOTED. COORDINATE
REQUIREMENTS WITH F.E.C.
E. FILL EXCESS DEPRESSIONS AROUND WALK-INS, FLOOR TROUGHS, WITH GROUT,
FINISHED FLOOR, AND MATCHING COVED BASE AFTER WALK-INS AND FLOOR
TROUGHS HAVE BEEN INSTALLED BY F.E.C.
F. PROVIDE MASONRY PADS, WHEN SHOWN, WITH TROWEL - SMOOTH AND LEVEL
FINISH.
H. PROVIDE FIRE-RATED MATERIALS AND/OR INSULATION AS REQUIRED FOR EXHAUST
DUCTS, VENT STACKS, PORTION OF EXHAUST HOODS ABOVE CEILING HEIGHT, HEAT
PRODUCING EQUIPMENT, ROOF/WALL PENETRATIONS, ETC.; PER LOCAL CODES.
I. PROVIDE COVED BASE MOLDING OR COVED INTEGRAL FLOOR MATERIALS AS
REQUIRED AT ALL VERTICAL SURFACES WHERE THEY MEET FLOORS IN
FOODSERVICE AREAS.
REFER TO FOOD SERVICE SHEETS QF601 & QF602 FOR UTILITY INFORMATION
WALL BACKING - BY G.C. VERIFY SIZE & LOCATION WITH F.E.C.A
3" X 3" X 60" HIGH 16 GA. S/S CORNER GUARDS, BY F.E.C.B
C1 PROVIDE 8" DEPRESSION FOR WALK-IN FLOORS - SEE
DETAIL ON THIS SHEET. COORDINATE EXISTING
STRUCTURE AND CONDITIONS.
57 63
F.S.
207207
206206 F.S.
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:2
P
M
QF133
PLUMBING ROUGH-IN PLAN CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 13 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
PLUMBING PLAN - PREP AREA
D2
REFER TO FOOD SERVICE SHEETS QF601 & QF602 FOR UTILITY INFORMATION
PLUMBING ROUGH-IN PLANS:
1. ROUGH-INS & CONNECTIONS SHOWN RELATE TO FOOD SERVICE EQUIPMENT ONLY.
PLUMBING DRAWINGS FOR ADDITIONAL REQUIREMENTS.
2. THIS PLUMBING PLAN IS INTENDED TO SHOW PRELIMINARY ROUGH-IN LOCATIONS &
HEIGHTS, CONNECTION SIZES & LOAD REQUIREMENTS.
3. FINAL CONNECTIONS TO FOOD SERVICE EQUIP. SHALL BE BY THE CONTRACTOR,
INCLUDING REQUIRED MATERIALS, SUCH AS STOPS, VALVES, FILTERS, TRAPS, CHECK
VALVES, PIPING, TUBING, ETC. UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
FURNISH BRASS BALL VALVE STOPS TO H/C WATER CONNECTIONS IN ACCORD WITH SIZE
OF FEED PIPE.
4. CONTRACTOR SHALL FURNISH & INSTALL THE FOLLOWING:
A. WATER, WASTE, GAS, STEAM, & AIR SERVICE FROM THE POINT OF ROUGH-IN TO
THE FOOD SERVICE FIXTURE & EQUIP. ITEMS AS SHOWN ON THE PLAN. ROUGH-IN
OUTLETS TO STUB 2" OUT OF WALLS AT HEIGHT INDICATED TO CENTERLINE OF
OUTLET. FLOOR ROUGH-INS TO STUB UP 4" (100 mm) A.F.F. OR CURB. FLOOR
OPENINGS &/OR PENETRATIONS SHALL BE WATER TIGHT & FIRE CAULKED .
B. FLOOR SINKS, COMPLETE GRATES, UNLESS OTHERWISE NOTED, & REMOVABLE
SEDIMENT BUCKETS SET FLUSH WITH FINISHED FLOOR, UNLESS OTHERWISE NOTED
OR REQUIRED BY CODE.
C. WASTE LINES, DIRECT & INDIRECT, EXCEPT AS NOTED OTHERWISE. MINIMUM
DIAMETER OF LINES SHALL BE AS NOTED IN THE PLUMBING CONNECTION
SCHEDULE, REGARDLESS OF CONNECTION SIZE, & SHALL BE PITCHED DOWNWARD.
MAINTAIN DRAINS AS HIGH AS POSSIBLE ABOVE FLOOR. PROVIDE CLEAN-OUTS ON
WASTE LINES.
D. INDIRECT WASTE LINES FOR WALK-IN REFRIGERATED BOXES SHALL BE
PITCHED A MINIMUM OF 1/4" PER FOOT WITH A "P" TRAP AT END OVER FLOOR SINK.
PIPING ON EXTERIOR SHALL BE PARALLEL TO WALK-IN. PENETRATE WALK-IN WALL
WITH WASTE LINE AT 1'-0" (300 mm) A.F.F.
E. INSTALL FIRE PROTECTION SYSTEM GAS SHUT-OFF VALVE(S), FURNISHED BY
THE CONTRACTOR, WHEN GAS COOKING EQUIP. IS USED.
EQUIPMENT NUMBER DESIGNATOR . SEE
EQUIPMENT LIST ON SAME SHEET OR
57 63
213 213 213 213
207 207
212 212 212
204 204 204
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:2
P
M
QF134
ELECTRICAL ROUGH-IN PLAN CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 14 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
ELECTRICAL PLAN - PREP AREA
D2
REFER TO FOOD SERVICE SHEETS QF601 & QF602 FOR UTILITY INFORMATION
ELECTRICAL ROUGH-IN PLAN:
1. ELECTRICAL SYSTEM IS DESIGNED FOR 120/208 VOLTS, 3 PHASE, 4 WIRE, 60 HERTZ,
UNLESS OTHERWISE NOTED.
2. OUTLETS & CONNECTIONS SHOWN RELATE TO FOOD SERVICE EQUIP. & FIXTURES
ONLY. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL REQUIREMENTS.
3. THIS ELECTRICAL PLAN IS INTENDED TO SHOW OUTLET TYPES, LOCATIONS, &
CONNECTION POSITIONS & LOADS.
4. ELECTRICAL WORK FOR FABRICATED FOOD SERVICE EQUIP. & FIXTURES, SHALL BE
COMPLETELY PRE-WIRED TO A JUNCTION-BOX MOUNTED ON THE EQUIPMENT, IN AN
ACCESSIBLE POSITION. FINAL CONNECTIONS TO THE FOOD SERVICE FIXTURES & EQUIP.
JUNCTION BOXES OR PULL BOXES, & ELECTRICAL WORK FROM PANEL BOXES SHALL BE
BY CONTRACTOR.
5. FINAL CONNECTIONS TO FOOD SERVICE EQUIP. & FIXTURES SHALL BE BY THE
CONTRACTOR, INCLUDING LABOR & MATERIALS.
6. CONTRACTOR SHALL FURNISH & INSTALL THE FOLLOWING:
A. JUNCTION BOXES, ELECTRICAL OUTLETS, COVER PLATES, SWITCHES, NOT BUILT INTO
THE EQUIP. & FIXTURES. OUTLETS, JUNCTION BOXES, & COVER PLATES.
B. SHUNT TRIP CIRCUIT BREAKERS OR DISCONNECTS FOR FIRE PROTECTION SYSTEM,
SHUT-OFF OF FOOD SERVICE EQUIP. ELECTRICAL CIRCUITS LOCATED BENEATH
EXHAUST HOODS AS REQUIRED BY N.F.P.A. & APPLICABLE CODES.
7. CONTRACTOR SHALL PROVIDE CIRCUIT(S) CONDUIT & WIRING, INST ELECTRICAL
COMPONENTS & INTERWIRE BETWEEN THE FOLLOWING:
A. REMOTE REFRIGERATION EQUIP. & EVAPORATOR COILS. INCLUDING NECESSARY
LIGHTS, ALARMS, HEATERS AND SWITCHES.
B. CONTROL PANELS TO WATER WASH EXHAUST HOODS & EXHAUST/SUPPLY FAN
MAGNETIC STARTERS PER MANUFACTURERS INSTRUCTION.
C. FOOD SERVICE EXHAUST HOODS TO FIRE PROTECTION SYSTEM & SHUT-OFFS.
D. FOOD SERVICE EXHAUST HOOD LIGHTS & SWITCHES.
EQUIPMENT NUMBER DESIGNATOR . SEE
EQUIPMENT LIST ON SAME SHEET OR
78 80 87 104
76 86
347 347 353352
357 356 356362363367 366 366
326 328
304 306 308
COLD COLD
BULK COOK
PREP
PREP
332 333
344 344 344
346 346 346
338 337
JAN.
322 321
336 336
336 336
336 336 BULK COOK
COMBI OVENS
364 361
351 351
303 307 311305 325325
337 337
355 355348 348
330 320
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:2
P
M
QF141
FOOD SERVICE EQUIPMENT PLAN CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 15 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
FOOD SERVICE EQUIPMENT PLAN - PREP & COOKING AREAS
D2
FOODSERVICE EQUIPMENT SCHEDULE
ITEM NO QTY ACQ/INS* NAME EQUIPMENT REMARKS
301 1 CC FIRE SUPPRESSION SYSTEM FOR ITEM #302
302 1 CC EXHAUST HOOD
303 1 CC FLOOR TROUGH & GRATE
304 1 VC 80-GALLON TILTING KETTLE ELECTRIC
305 1 CC FLOOR TROUGH & GRATE
306 1 VC 80-GALLON TILTING KETTLE ELECTRIC
307 1 CC FLOOR TROUGH & GRATE
308 1 VC 80-GALLON TILTING KETTLE ELECTRIC
309 - SPARE NUMBER
310 - SPARE NUMBER
311 1 CC FLOOR TROUGH & GRATE
312 1 VC 80-GALLON TILTING KETTLE ELECTRIC
313 1 CC MOP SINK
314 1 VC 60 QT MIXER
315 - SPARE NUMBER
316 1 CC PREP TABLE W/SINKS
317 1 CC HAND SINK
318 - SPARE NUMBER
319 - SPARE NUMBER
320 2 CC PASS-THRU SHELF
321 1 VC 20-QUART MIXER
322 1 VC MIXER STAND
323 1 CC PREP TABLE W/SINKS
324 1 CC HAND SINK
325 2 VC POT/PAN DRYING RACK
326 1 VV UTILITY RACK
327 1 CC PREP TABLE W/SINKS
328 1 CC HAND SINK
329 - SPARE NUMBER
330 2 CC PASS-THRU SHELF
331 1 VC POTATO/VEGETABLE PEELER
332 1 CC PREP TABLE W/SINKS
333 1 VC FOOD PROCESSOR
334 1 CC HAND SINK
335 - SPARE NUMBER
336 6 VC MOBILE COMBI TRAY RACK
337 3 VC WORK TABLE
338 1 VC WORK TABLE
339 - SPARE NUMBER
340 - SPARE NUMBER
341 1 CC HAND SINK
342 1 CC FIRE SUPPRESSION SYSTEM FOR ITEM #343
343 1 CC EXHAUST HOOD
344 4 VC ROLL-IN COMBI OVEN ELECTRIC
345 - SPARE NUMBER
346 4 VC WATER FILTER
347 2 VC 40-GALLON TILTING SKILLET ELECTRIC
348 2 VC WATER FILTER
349 - SPARE NUMBER
350 - SPARE NUMBER
351 3 CC FLOOR TROUGH & GRATE
352 1 CC EXHAUST HOOD
353 1 CC FIRE SUPPRESSION SYSTEM FOR ITEM #352
354 1 CC HAND SINK
355 2 VC CONVECTION STEAMER ELECTRIC/LOW-WATTAGE OPTION
356 2 VC UTILITY RACK
357 1 VC ROLL-IN REFRIGERATOR
358 1 VC REACH-IN FREEZER
359 - SPARE NUMBER
360 - SPARE NUMBER
361 1 CC PREP TABLE W/SINKS CUSTOM FABRICATION
362 1 CC HAND SINK
363 1 CC HAND SINK
364 1 CC PREP TABLE W/SINKS CUSTOM FABRICATION
365 - SPARE NUMBER
366 2 VC UTILITY RACK
367 1 VC ROLL-IN REFRIGERATOR
368 - SPARE NUMBER
369-400 - SPARE NUMBER
*ACQUIRED/INSTALLED
CC: CONTRACTOR PROVIDED CONTRACTOR INSTALLED
VC: VA PROVIDED/CONTRACTOR INSTALLED
VV: VA PROVIDED/VA INSTALLED
1. SEE SHEET QF600 FOR UTILITY INFORMATION.
2. CONTRACTOR RESPONSIBLE FOR EQUIPMENT LEAD TIMES BASED ON
INSTALLATION SCHEDULE AND PHASING.
EQUIPMENT NUMBER DESIGNATOR . SEE
EQUIPMENT LIST ON SAME SHEET OR
78 80 87 104
76 86
A
B
DF
E
F
D D
F
E
A
A
A
A
BB B
A
BB
B B
B
B A A A
A
A
B
F
E
B
A
B B B
B
B
343 AB
352 AB
D D D
A B
144" WIDE FLOOR-TO-
CIELING WALL
OPENING FOR TABLES
AND SHELF
144" WIDE FLOOR-TO-
CIELING WALL
OPENING FOR TABLES
AND SHELF
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s ho lle y\
D oc um en ts \V
A D
U B
LI
N
_F S
_R
_C E
N T
R A
L_ sh ol le yP P
2S K
.r vt
7/
/2
2:
:2
P
M
QF142
BUILDING CONDITIONS @
VENTILATION PLAN
CORRECT SAFETY & FCA
DEFICIENCIES
1826 VETERANS BLVD, DUBLIN, GA 31021
557-21-101
07/19/2023 TG SH
100% STAMPED
SUBMITTAL
VEG 21.31 DWG 16 of 61 T H
IR
D
R E
V
IE
W S
U B
M
IS
S
IO
N P
H A
S E
16'8'4'2'1'0'
1/4" = 1'-0"
BUILDING CONDITIONS & VENT. PLAN - PREP & COOKING AREAS
D2
KITCHEN BUILDING CONDITIONS & VENTILATION :
1. ALL WORK INDICATED ON THIS PLAN AND IN THESE NOTES ARE TO BE BY OTHERS THAN
THE FOODSERVICE EQUIPMENT CONTRACTOR (F.E.C.) UNLESS NOTED.
2. WALLS, FLOORS, AND CEILINGS IN KITCHEN, PREPARATION, SERVICE, AND
WAREWASHING AREAS OR ANY OTHER LOCATION WHERE FOOD AND/OR BEVERAGES ARE
PREPARED, MUST BE SMOOTH, EASILY CLEANABLE, NON - ABSORBENT, AND DURABLE.
WALLS AND CEILINGS ARE TO BE LIGHT COLORED.
3. FINAL DUCT CONNECTIONS ARE BY MECHANICAL CONTRACTOR.
4. ROUGH-IN/CONNECTION HEIGHTS NOTED ON THE MECHANICAL CONNECTION SCHEDULE
INDICATE HEIGHT ABOVE FINISHED FLOOR (A.F.F.)
5. ASSURE THE FOLLOWING AMONGST THE TRADES:
A. IN-WALL REINFORCING OR BACKING AS REQUIRED FOR WALL MOUNTED KITCHEN
EQUIPMENT, COORDINATE SIZE, MOUNTING HEIGHTS AND INSTALLATION
REQUIREMENTS WITH F.E.C. MOUNT ALL SHELVES AT 54" AND 66" -A.F.F., UNLESS
OTHERWISE NOTED.
B. SLOPE FLOORS TO FLOOR DRAINS, AND FLOOR TROUGHS.
C. PROVIDE DOOR/WALL OPENINGS AND/OR PASSAGES TO ASSURE ACCESS FOR ALL
KITCHEN EQUIPMENT.
D. PROVIDE WALK-IN REFRIGERATION DEPRESSIONS, SMOOTH AND TRANSIT - LEVEL,
WHERE DEPRESSIONS ARE REQUIRED. DEPTH AS NOTED. COORDINATE
REQUIREMENTS WITH F.E.C.
E. FILL EXCESS DEPRESSIONS AROUND WALK-INS, FLOOR TROUGHS, WITH GROUT,
FINISHED FLOOR, AND MATCHING COVED BASE AFTER WALK-INS AND FLOOR
TROUGHS HAVE BEEN INSTALLED BY F.E.C.
F. PROVIDE MASONRY PADS, WHEN SHOWN, WITH TROWEL - SMOOTH AND LEVEL
FINISH.
H. PROVIDE FIRE-RATED MATERIALS AND/OR INSULATION AS REQUIRED FOR EXHAUST
DUCTS, VENT STACKS, PORTION OF EXHAUST HOODS ABOVE CEILING HEIGHT, HEAT
PRODUCING EQUIPMENT, ROOF/WALL PENETRATIONS, ETC.; PER LOCAL CODES.
I. PROVIDE COVED BASE MOLDING OR COVED INTEGRAL FLOOR MATERIALS AS
REQUIRED AT ALL VERTICAL SURFACES WHERE THEY MEET FLOORS IN
FOODSERVICE AREAS.
NOT TO SCALE
FLOOR TROUGH DETAIL
GRATE: 1" X 3/16" S/S BAR
ON 1" CENTERS. 2' MAX.
LENGTH OF SECTION
PAN TO BE
PITCHED TO DRAIN
6" T
YP
DE
PR
SS
N.
FINISHED FLOOR
AS SPECIFIED
BY ARCHITECT
W
ID
TH
A
S
PE
R
PL
AN
5/8"" DIA. S/S RODS 4"
MAXIMUM SPACING
SLAB DEPRESSION
SEE BLDG. COND. PLAN
TROUGH DIMENSION
SEE EQUIP. PLAN
6" T
YP
PA
N
DE
PT
H
GROUT AFTER
SETTING AND
SEALING PAN
STAINLESS STEEL FLOOR TROUGH WITH PAN
AND GRATE TO BE FURNISHED BY KITCHEN EQUIPMENT
CONTRACTOR AND CONNECTED BY PLUMBING
CONTRACTOR (P.C.) IN ACCORDANCE WITH ALL LOCAL
ANDSTATE CODES. GENERAL CONTRACTOR TO VERIFY
TOTAL THICKNESS OF TILE AND SETTING BED.
INSTALLATION SHALL BE BY GENERAL CONTRACTOR.
G.C. TO GROUT AFTER SETTING AND SEALING
OF PAN. K.E.C. TO COORDINATE WITH G.C.
LENGTH AS PER PLAN
DRAIN LINE BY P.C.
G.C. TO COORDINATE
W/ K.E.C. SIZE & METHOD
OF ATTACHMENT.
SQUARE CUT-OUT
EXISTINGCONCRETE
SLAB BY G.C.
#16 GA. S/S TAIL PIECE
NOTE:
PLAN VIEW
D
REFER TO FOOD SERVICE SHEETS QF601 & QF602 FOR UTILITY INFORMATION
WALL BACKING - BY G.C. VERIFY SIZE & LOCATION WITH F.E.C.A
3" X 3" X 60" HIGH 16 GA. S/S CORNER GUARDS, BY F.E.C.B
D PROVIDE DEPRESSION FOR FLOOR TROUGH - SEE
DETAIL ON THIS SHEET. COORDINATE EXISTING
STRUCTURE AND CONDITIONS.
20 GA. S/S WALL FLASHING FROM BASE COVE TO
BOTTOM LINE OF HOOD BY F.E.C. (INCLUDE WITH THE
HOOD @ WALL LOCATION)
E
F PROVIDE FOR NON-COMBUSTIBLE WALL CONSTRUCTION @ ALL
COOK LINE WALLS
78 80 87 104
76 86
332 334
347 351344344341
346 346 346 346363 362 361
307 311
F.S. F.S.
331331 332
324324
328328 334334
304304
306306 308308 312312
F.S. F.S.
344344 344344
F.S.
364364 363363
F.S.
362362 361
354354
347 347347341341
355355 355
348348
F.S.
00KEYNOTES
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
NOT FOR
CONSTRUCTION
Date:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
8055 EAST TUFTS AVE
SUITE 1320
DENVER, CO 80237
(303) 649-1600
WWW.YOUNGCARUSO.COM
C :\U se rs
\s…