619A4-23-103_ICRA Breakdown_9.30.25.xlsx

XLSX spreadsheet 12 KB Posted

Attached to
Replace Fire Alarm System for Buildings 15, 65, 68, 88, 90, & 93
Solicitation number
36C24726R0028
Issued by

About this file

This file is an ICRA (Infection Control Risk Assessment) Breakdown spreadsheet detailing demolition and new work activities across multiple buildings at the Central Alabama Veterans Health Care System facility in Tuskegee, Alabama for Project No. 619A4-23-103.

The spreadsheet identifies specific building locations, floor assignments, affected rooms, and associated risk classifications for both demolition and new work phases. Demolition activities are mapped across Buildings 2, 3, 3A, 4, 4A, 5, 10, 12, 13, 14, 15, 18, 65, 68, 83, 88, 90, 93, 97, 120, and 129, with affected areas including offices, utility rooms, corridors, and specialized spaces such as optical shops, boiler plants, and chiller plants. New work activities are distributed similarly across the facility's basement, first, second, and attic levels. Risk levels are classified as Low, Medium, or High, with corresponding Class designations (Class II, III, or IV), where Class IV represents the highest risk and applies to spaces such as the MH Group Room, Men's restroom areas, and Security Officer locations. This ICRA breakdown serves as a planning document for the fire alarm system replacement project affecting Buildings 14, 15, 65, 68, 88, 90, and 93, providing contractors with detailed information on infection control considerations and work area classifications necessary for safe project execution within the healthcare facility environment.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Demolition Plan
BuildingFloor/RoomAffected LocationsRisk LevelClassLevel
2103DAV OfficeLowCII
3A101Social Work OfficeLowCII
4A110MH Group RoomHighCIV
5BBasementElevator, Stairs, CorridorLowCII
90140, 141Optical shop, GECRMediumCIII
Fire Alarm New Work
BuildingFloorRoomAffected LocationsRisk LevelClassLevel
2Basement3EMS StorageLowCII
21stC-1, 106, 105, 104, 103, 102, 102ACorridor, HAS Offices, Museum, ROILowCII
31st101, 103, 126, 125A, RCC109RMen's restroom, Supply room, Kitchen, MOD/WH med room, CorridorHighCIV
3ABasement12A, 10, 9, 8B, BC-1, BC-2, 6B, 6C, 17, 5, 4, RCCB04R, 17Vacant, Engineering and utility rooms, Veteran clothing storage, corridorsLowCII
3A1st101, C-1, 101Social Work office, corridor, Public RestroomLowCII
41stRCC119R, 120, 103Police dispatch, Vending, corridorLowCII
4ABasement2, 3, 7, 8A, RCCB03ROIT, VSO, VacantLowCII
4A1st110, RCC106R, 109, 108, RCC113RMH Group Room, Corridor, Security Officer, MH officeHighCIV
5BasementRCCB05R, 22, 25, 32Corridor/elevator lobby, EngineeringLowCII
101stVacantLowCII
12BasementBoiler PlantLowCII
121stBoiler PlantLowCII
131stEngineeringLowCII
141stEngineeringLowCII
151stEngineering, Fire DepartmentLowCII
181stVacantLowCII
651stVacantLowCII
68BasementEngineering, Safety, CDCE, Supply chainMediumCIII
681stHR, EMS, PIVLowCII
682ndEducation, FMS, Supply ChainLowCII
68AtticAtticLowCII
83BasementC11, B4Corridor, EngineeringLowCII
831stRCC112RCorridorLowCII
881stWarehouseLowCII
901st140, 141, 102, 103, RCC136R, 127, RCC117RGECR Storage, Conference Room, Reception, Optic Shop, Male Restroom, BilliardsMediumCIII
931stChapelLowCII
97BasementChiller PlantLowCII
971stChiller PlantLowCII
120BasementEC05, RG03, G11, G10, G09, 006DCorridor, Engineering, EMS StorageLowCII
5, 120, 129BasementTunnelCorridorLowCII
129BasementCG-6, RCCG01R, CG-7Corridors, GECR StorageLowCII
1291stC1-4Main entrance corridorLowCII