This document is an Asbestos Analysis Test Report from EMSL Analytical, Inc. for the Central AL Veterans Health Care System, specifically documenting roof sampling for Buildings 4 and 90. The comprehensive report analyzes multiple layers of roofing materials from different areas including Canteen Retail, Pool, Recreation Services, and Big Room sections, using Polarized Light Microscopy following AHERA Method 40CFR 763 Subpart E.

The analysis involved 10 distinct sample sets with multiple layers per set, examining materials such as shingles, felt, tar, and various roofing components. Critically, none of the samples detected asbestos, with most layers composed of non-fibrous materials like glass, cellulose, and synthetic materials. The samples were collected on 03/12/2025, received on 03/13/2025, and analyzed between 03/19/2025 and 03/20/2025, with the final report issued on 03/20/2025. The testing was conducted for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 7, associated with solicitation number 36C24725R0018 for replacing and repairing roofs on Buildings 4, 15, 90, and 93.

View the file

Other files

File Type Posted
1352.011 Roof Replace Repair Bldgs 4 15 90 and 93 Addenda 2.pdf PDF
Combined Pre-Bid RFIs - 2-LL.docx DOCX document
1352.011 Section 02 82 13.21 Asbestos Roofing Abatement - Add 2.pdf PDF
1352.011 Section 01 00 00 General Requirements - Add 2.pdf PDF
1352.011 Section 07 01 50.19 Preparation for Re-Roofing - Add 2.pdf PDF
Amendment 0008 36C24725R0018.pdf PDF
1352.011 Section 01 11 00 Summary of Work - ADD 2.pdf PDF
1352.011 Section 01 22 13 Unit Prices and Allowances - Add 2.pdf PDF
Amendment 36C24725R0018 0007.pdf PDF
Amendment 006 36C24725R0018.pdf PDF
Combined Pre-Bid RFIs - 2 -.pdf PDF
amendment 36C24725R0018 0005.pdf PDF
36C24725R0018 0004.pdf PDF
619A4-23-101 Site Visit Sign In 1-16.pdf PDF
36C24725R0018 0003.pdf PDF
619A4-23-101 Site Visit Sign In.pdf PDF
Site Visit Attendance Sheet - 6194A-23-101.pdf PDF
S06 36C24725R0018 0002.pdf PDF
Amended submition date 36C24725R0018 0001.pdf PDF
Attachment 6 - INVOICING.docx DOCX document
Attachment 8 - Bldg 4 90 Roof Replacement Construction Drawings.pdf PDF
Attachment 2 - 852.219-75 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING Jan 2023 Dev form.pdf PDF
Attachment 5 - DBA AL20240078 SAM.gov.pdf PDF
Attachment 7 - Bldg 4 90 Roof Replace CD Specificaitons.pdf PDF
Attachment 4 - Itemized Cost Breakdown.xlsx XLSX spreadsheet
Attachment 1 - Experience Modification Rate Form.pdf PDF
Attachment 3 - Past Performance Questionnaire -PPQ.docx DOCX document
36C24725R0018_1.docx DOCX document
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EMSL Analytical, Inc.

2205 Corporate Plaza Parkway SE, Suite 200 Smyrna, GA 30080

Tel/Fax: (770) 956-9150 / (770) 956-9181 http://www.EMSL.com / atlantalab@emsl.com

072502445EMSL Order:

Customer ID: CAVH62

Customer PO: 619-P51832

Project ID:

Attention: Phone:Stan Strickland (334) 725-2839

Fax:Central AL Veterans Health Care System (334) 724-6813

Received Date:Mail Stop 001S 03/13/2025 10:20 AM

Analysis Date:2400 Hospital Road 03/19/2025 - 03/20/2025

Collected Date:Tuskegee, AL 36083 03/12/2025

Project: Roof Sampling (4 & 90)

Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E

Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

1-Shingle

072502445-0001

None DetectedNon-fibrous (Other)95%Glass5%Black

Fibrous

Homogeneous

Shingle And Tar

Paper - Building 4

Roof

HA: 001

1-Felt

072502445-0001A

None DetectedNon-fibrous (Other)95%Glass5%Black

Fibrous

Homogeneous

Shingle And Tar

Paper - Building 4

Roof

HA: 001

1-Tar

072502445-0001B

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Shingle And Tar

Paper - Building 4

Roof

HA: 001

2-Shingle

072502445-0002

None DetectedNon-fibrous (Other)90%Glass10%Black

Fibrous

Homogeneous

Shingle And Tar

Paper - Building 4

Roof

HA: 001

2-Felt

072502445-0002A

None DetectedNon-fibrous (Other)95%Glass5%Black

Fibrous

Homogeneous

Shingle And Tar

Paper - Building 4

Roof

HA: 001

2-Tar

072502445-0002B

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Shingle And Tar

Paper - Building 4

Roof

HA: 001

3-Shingle

072502445-0003

None DetectedNon-fibrous (Other)95%Glass5%Black

Fibrous

Homogeneous

Shingle And Tar

Paper - Building 4

Roof

HA: 001

3-Felt

072502445-0003A

None DetectedNon-fibrous (Other)95%Glass5%Black

Fibrous

Homogeneous

Shingle And Tar

Paper - Building 4

Roof

HA: 001

3-Tar

072502445-0003B

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Shingle And Tar

Paper - Building 4

Roof

HA: 001

4-Layer 1

072502445-0004

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Canteen Retail)

HA: 002

4-Layer 2

072502445-0004A

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Canteen Retail)

HA: 002

4-Layer 3

072502445-0004B

None DetectedNon-fibrous (Other)20%Cellulose80%Brown

Fibrous

Homogeneous

Field - Building 90

Roof (Canteen Retail)

HA: 002

Initial report from: 03/20/2025 08:07:15

Page 1 of 4ASB_PLM_0008_0002 - 2.31 Printed: 3/20/2025 8:07 AM

Tel/Fax: (770) 956-9150 / (770) 956-9181 http://www.EMSL.com / atlantalab@emsl.com

072502445EMSL Order:

Customer ID: CAVH62

Customer PO: 619-P51832

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E

Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

4-Layer 4

072502445-0004C

None DetectedNon-fibrous (Other)20%Cellulose80%Brown

Fibrous

Homogeneous

Field - Building 90

Roof (Canteen Retail)

HA: 002

4-Layer 5

072502445-0004D

None DetectedNon-fibrous (Other)95%Glass5%Black

Fibrous

Homogeneous

Field - Building 90

Roof (Canteen Retail)

HA: 002

4-Layer 6

072502445-0004E

None DetectedNon-fibrous (Other)90%Glass10%Black

Fibrous

Homogeneous

Field - Building 90

Roof (Canteen Retail)

HA: 002

4-Layer 7

072502445-0004F

None DetectedNon-fibrous (Other)90%Glass10%Black

Fibrous

Homogeneous

Field - Building 90

Roof (Canteen Retail)

HA: 002

4-Layer 8

072502445-0004G

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Canteen Retail)

HA: 002

5-Layer 1

072502445-0005

None DetectedNon-fibrous (Other)20%Cellulose80%Brown

Fibrous

Homogeneous

Field - Building 90

Roof (Pool)

HA: 002

5-Layer 2

072502445-0005A

None DetectedNon-fibrous (Other)20%Cellulose80%Brown

Fibrous

Homogeneous

Field - Building 90

Roof (Pool)

HA: 002

5-Layer 3

072502445-0005B

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Pool)

HA: 002

5-Layer 4

072502445-0005C

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Pool)

HA: 002

5-Layer 5

072502445-0005D

None DetectedNon-fibrous (Other)95%Glass5%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Pool)

HA: 002

5-Layer 6

072502445-0005E

None DetectedNon-fibrous (Other)95%Synthetic5%Black

Fibrous

Homogeneous

Field - Building 90

Roof (Pool)

HA: 002

5-Layer 7

072502445-0005F

None DetectedNon-fibrous (Other)95%Glass5%Black

Fibrous

Homogeneous

Field - Building 90

Roof (Pool)

HA: 002

5-Layer 8

072502445-0005G

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Pool)

HA: 002

6-Layer 1

072502445-0006

None DetectedNon-fibrous (Other)20%Cellulose80%Brown

Fibrous

Homogeneous

Field - Building 90

Roof (Rec. Services)

HA: 002

6-Layer 2

072502445-0006A

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Rec. Services)

Page 2 of 4ASB_PLM_0008_0002 - 2.31 Printed: 3/20/2025 8:07 AM

Tel/Fax: (770) 956-9150 / (770) 956-9181 http://www.EMSL.com / atlantalab@emsl.com

072502445EMSL Order:

Customer ID: CAVH62

Customer PO: 619-P51832

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E

Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

HA: 002

6-Layer 3

072502445-0006B

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Rec. Services)

HA: 002

6-Layer 4

072502445-0006C

None DetectedNon-fibrous (Other)95%Cellulose5%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Rec. Services)

HA: 002

6-Layer 5

072502445-0006D

None DetectedNon-fibrous (Other)95%Glass5%Black

Fibrous

Homogeneous

Field - Building 90

Roof (Rec. Services)

HA: 002

6-Layer 6

072502445-0006E

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Rec. Services)

HA: 002

7-Layer 1

072502445-0007

None DetectedNon-fibrous (Other)20%Cellulose80%Brown

Fibrous

Homogeneous

Field - Building 90

Roof (Big Room)

HA: 002

7-Layer 2

072502445-0007A

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Big Room)

HA: 002

7-Layer 3

072502445-0007B

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Big Room)

HA: 002

7-Layer 4

072502445-0007C

None DetectedNon-fibrous (Other)95%Cellulose5%Black

Fibrous

Homogeneous

Field - Building 90

Roof (Big Room)

HA: 002

7-Layer 5

072502445-0007D

None DetectedNon-fibrous (Other)95%Glass5%Black

Fibrous

Homogeneous

Field - Building 90

Roof (Big Room)

HA: 002

7-Layer 6

072502445-0007E

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Field - Building 90

Roof (Big Room)

HA: 002

8-Layer 1

072502445-0008

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Flashing - Building 90

Roof (Canteen Retail)

HA: 003

8-Layer 2

072502445-0008A

None DetectedNon-fibrous (Other)97%Cellulose3%Black

Non-Fibrous

Homogeneous

Flashing - Building 90

Roof (Canteen Retail)

HA: 003

9-Layer 1

072502445-0009

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Flashing - Building 90

Roof (Pool)

HA: 003

9-Layer 2

072502445-0009A

None DetectedNon-fibrous (Other)95%Glass5%Black

Fibrous

Homogeneous

Flashing - Building 90

Roof (Pool)

HA: 003

Page 3 of 4ASB_PLM_0008_0002 - 2.31 Printed: 3/20/2025 8:07 AM

Tel/Fax: (770) 956-9150 / (770) 956-9181 http://www.EMSL.com / atlantalab@emsl.com

072502445EMSL Order:

Customer ID: CAVH62

Customer PO: 619-P51832

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E

Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

10-Layer 1

072502445-0010

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Flashing - Building 90

Roof (Rec. Services)

HA: 003

10-Layer 2

072502445-0010A

None DetectedNon-fibrous (Other)95%Cellulose5%Black

Non-Fibrous

Homogeneous

Flashing - Building 90

Roof (Rec. Services)

HA: 003

Analyst(s)

Anthony Sanaie (43) Violedah Richardson, Laboratory Manager or Other Approved Signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.

Samples analyzed by EMSL Analytical, Inc Smyrna, GA NVLAP Lab Code 101048-1