This document is an Asbestos Analysis Test Report from EMSL Analytical, Inc. for the Central AL Veterans Health Care System, specifically documenting roof sampling for Buildings 4 and 90. The comprehensive report analyzes multiple layers of roofing materials from different areas including Canteen Retail, Pool, Recreation Services, and Big Room sections, using Polarized Light Microscopy following AHERA Method 40CFR 763 Subpart E.
The analysis involved 10 distinct sample sets with multiple layers per set, examining materials such as shingles, felt, tar, and various roofing components. Critically, none of the samples detected asbestos, with most layers composed of non-fibrous materials like glass, cellulose, and synthetic materials. The samples were collected on 03/12/2025, received on 03/13/2025, and analyzed between 03/19/2025 and 03/20/2025, with the final report issued on 03/20/2025. The testing was conducted for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 7, associated with solicitation number 36C24725R0018 for replacing and repairing roofs on Buildings 4, 15, 90, and 93.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EMSL Analytical, Inc.
2205 Corporate Plaza Parkway SE, Suite 200 Smyrna, GA 30080
Tel/Fax: (770) 956-9150 / (770) 956-9181 http://www.EMSL.com / atlantalab@emsl.com
072502445EMSL Order:
Customer ID: CAVH62
Customer PO: 619-P51832
Project ID:
Attention: Phone:Stan Strickland (334) 725-2839
Fax:Central AL Veterans Health Care System (334) 724-6813
Received Date:Mail Stop 001S 03/13/2025 10:20 AM
Analysis Date:2400 Hospital Road 03/19/2025 - 03/20/2025
Collected Date:Tuskegee, AL 36083 03/12/2025
Project: Roof Sampling (4 & 90)
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1-Shingle
072502445-0001
None DetectedNon-fibrous (Other)95%Glass5%Black
Fibrous
Homogeneous
Shingle And Tar
Paper - Building 4
Roof
HA: 001
1-Felt
072502445-0001A
None DetectedNon-fibrous (Other)95%Glass5%Black
Fibrous
Homogeneous
Shingle And Tar
Paper - Building 4
Roof
HA: 001
1-Tar
072502445-0001B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Shingle And Tar
Paper - Building 4
Roof
HA: 001
2-Shingle
072502445-0002
None DetectedNon-fibrous (Other)90%Glass10%Black
Fibrous
Homogeneous
Shingle And Tar
Paper - Building 4
Roof
HA: 001
2-Felt
072502445-0002A
None DetectedNon-fibrous (Other)95%Glass5%Black
Fibrous
Homogeneous
Shingle And Tar
Paper - Building 4
Roof
HA: 001
2-Tar
072502445-0002B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Shingle And Tar
Paper - Building 4
Roof
HA: 001
3-Shingle
072502445-0003
None DetectedNon-fibrous (Other)95%Glass5%Black
Fibrous
Homogeneous
Shingle And Tar
Paper - Building 4
Roof
HA: 001
3-Felt
072502445-0003A
None DetectedNon-fibrous (Other)95%Glass5%Black
Fibrous
Homogeneous
Shingle And Tar
Paper - Building 4
Roof
HA: 001
3-Tar
072502445-0003B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Shingle And Tar
Paper - Building 4
Roof
HA: 001
4-Layer 1
072502445-0004
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Canteen Retail)
HA: 002
4-Layer 2
072502445-0004A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Canteen Retail)
HA: 002
4-Layer 3
072502445-0004B
None DetectedNon-fibrous (Other)20%Cellulose80%Brown
Fibrous
Homogeneous
Field - Building 90
Roof (Canteen Retail)
HA: 002
Initial report from: 03/20/2025 08:07:15
Page 1 of 4ASB_PLM_0008_0002 - 2.31 Printed: 3/20/2025 8:07 AM
Tel/Fax: (770) 956-9150 / (770) 956-9181 http://www.EMSL.com / atlantalab@emsl.com
072502445EMSL Order:
Customer ID: CAVH62
Customer PO: 619-P51832
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
4-Layer 4
072502445-0004C
None DetectedNon-fibrous (Other)20%Cellulose80%Brown
Fibrous
Homogeneous
Field - Building 90
Roof (Canteen Retail)
HA: 002
4-Layer 5
072502445-0004D
None DetectedNon-fibrous (Other)95%Glass5%Black
Fibrous
Homogeneous
Field - Building 90
Roof (Canteen Retail)
HA: 002
4-Layer 6
072502445-0004E
None DetectedNon-fibrous (Other)90%Glass10%Black
Fibrous
Homogeneous
Field - Building 90
Roof (Canteen Retail)
HA: 002
4-Layer 7
072502445-0004F
None DetectedNon-fibrous (Other)90%Glass10%Black
Fibrous
Homogeneous
Field - Building 90
Roof (Canteen Retail)
HA: 002
4-Layer 8
072502445-0004G
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Canteen Retail)
HA: 002
5-Layer 1
072502445-0005
None DetectedNon-fibrous (Other)20%Cellulose80%Brown
Fibrous
Homogeneous
Field - Building 90
Roof (Pool)
HA: 002
5-Layer 2
072502445-0005A
None DetectedNon-fibrous (Other)20%Cellulose80%Brown
Fibrous
Homogeneous
Field - Building 90
Roof (Pool)
HA: 002
5-Layer 3
072502445-0005B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Pool)
HA: 002
5-Layer 4
072502445-0005C
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Pool)
HA: 002
5-Layer 5
072502445-0005D
None DetectedNon-fibrous (Other)95%Glass5%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Pool)
HA: 002
5-Layer 6
072502445-0005E
None DetectedNon-fibrous (Other)95%Synthetic5%Black
Fibrous
Homogeneous
Field - Building 90
Roof (Pool)
HA: 002
5-Layer 7
072502445-0005F
None DetectedNon-fibrous (Other)95%Glass5%Black
Fibrous
Homogeneous
Field - Building 90
Roof (Pool)
HA: 002
5-Layer 8
072502445-0005G
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Pool)
HA: 002
6-Layer 1
072502445-0006
None DetectedNon-fibrous (Other)20%Cellulose80%Brown
Fibrous
Homogeneous
Field - Building 90
Roof (Rec. Services)
HA: 002
6-Layer 2
072502445-0006A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Rec. Services)
Page 2 of 4ASB_PLM_0008_0002 - 2.31 Printed: 3/20/2025 8:07 AM
Tel/Fax: (770) 956-9150 / (770) 956-9181 http://www.EMSL.com / atlantalab@emsl.com
072502445EMSL Order:
Customer ID: CAVH62
Customer PO: 619-P51832
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
HA: 002
6-Layer 3
072502445-0006B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Rec. Services)
HA: 002
6-Layer 4
072502445-0006C
None DetectedNon-fibrous (Other)95%Cellulose5%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Rec. Services)
HA: 002
6-Layer 5
072502445-0006D
None DetectedNon-fibrous (Other)95%Glass5%Black
Fibrous
Homogeneous
Field - Building 90
Roof (Rec. Services)
HA: 002
6-Layer 6
072502445-0006E
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Rec. Services)
HA: 002
7-Layer 1
072502445-0007
None DetectedNon-fibrous (Other)20%Cellulose80%Brown
Fibrous
Homogeneous
Field - Building 90
Roof (Big Room)
HA: 002
7-Layer 2
072502445-0007A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Big Room)
HA: 002
7-Layer 3
072502445-0007B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Big Room)
HA: 002
7-Layer 4
072502445-0007C
None DetectedNon-fibrous (Other)95%Cellulose5%Black
Fibrous
Homogeneous
Field - Building 90
Roof (Big Room)
HA: 002
7-Layer 5
072502445-0007D
None DetectedNon-fibrous (Other)95%Glass5%Black
Fibrous
Homogeneous
Field - Building 90
Roof (Big Room)
HA: 002
7-Layer 6
072502445-0007E
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Field - Building 90
Roof (Big Room)
HA: 002
8-Layer 1
072502445-0008
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Flashing - Building 90
Roof (Canteen Retail)
HA: 003
8-Layer 2
072502445-0008A
None DetectedNon-fibrous (Other)97%Cellulose3%Black
Non-Fibrous
Homogeneous
Flashing - Building 90
Roof (Canteen Retail)
HA: 003
9-Layer 1
072502445-0009
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Flashing - Building 90
Roof (Pool)
HA: 003
9-Layer 2
072502445-0009A
None DetectedNon-fibrous (Other)95%Glass5%Black
Fibrous
Homogeneous
Flashing - Building 90
Roof (Pool)
HA: 003
Page 3 of 4ASB_PLM_0008_0002 - 2.31 Printed: 3/20/2025 8:07 AM
Tel/Fax: (770) 956-9150 / (770) 956-9181 http://www.EMSL.com / atlantalab@emsl.com
072502445EMSL Order:
Customer ID: CAVH62
Customer PO: 619-P51832
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
10-Layer 1
072502445-0010
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Flashing - Building 90
Roof (Rec. Services)
HA: 003
10-Layer 2
072502445-0010A
None DetectedNon-fibrous (Other)95%Cellulose5%Black
Non-Fibrous
Homogeneous
Flashing - Building 90
Roof (Rec. Services)
HA: 003
Analyst(s)
Anthony Sanaie (43) Violedah Richardson, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc Smyrna, GA NVLAP Lab Code 101048-1
Page 4 of 4ASB_PLM_0008_0002 - 2.31 Printed: 3/20/2025 8:07 AM