This document is a limited hazardous materials survey report for the 4th floor of Building 143 at the Salem Veterans Affairs Medical Center in Salem, Virginia. The report details the results of asbestos sampling conducted in the Central Elevator Lobby area and adjoining H and J Wings. One hundred seventy-four samples were collected and analyzed, with no asbestos detected in any of the materials. Presumed asbestos containing materials that were not sampled due to inaccessibility or the potential for damage include fire door interiors, concealed piping or duct insulation, and vapor barriers underlying ceramic floor tiles in restrooms. The report also summarizes EPA NESHAP regulations for asbestos containing materials and OSHA requirements for worker exposure. This survey appears to be related to the federal contract opportunity to renovate patient privacy areas in Phase II of a project at this same Veterans Affairs medical center location.
View the file
Other files for this federal contract opportunity
Show all 39
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5238 VALLEYPOINTE PARKWAY
SUITE 2B, BUILDING C
ROANOKE, VA 24019
800-242-4906 TOLL FREE
540-521-1008 MAIN
www.HandP.com
ENGINEERING • SURVEYING • PLANNING • ENVIRONMENTAL • GIS
HURT & PROFFITT
Inspired | Responsive | Trusted
May 20, 2019
BES Design/Build LLC 766 Middle Street Fairhope, Alabama 36532
Attention: Richard F. Holihan and Katie Sharples Phone: 843.522.2094
Email: rholihan@besbeaufort.com, ksharpless@besdesignbuild.com
Subject: Limited Hazardous Materials Survey Building 143, 4th Floor - Central Elevator Lobby and H Wing 1970 Roanoke Boulevard Salem, Virginia H&P Project 20190443
Mr. Holihan, Hurt & Proffitt, Inc. (H&P) was requested to conduct sampling of suspect asbestos containing materials (ACM) and lead based painted building materials and to identify potential mercury and PCB containing components in Building 143 on the 4th Floor at Salem Veterans Affairs Medical Center in Salem, Virginia.
The sampling and review of the Central Elevator Lobby area was performed by H&P representatives Roy Wriston (Virginia Asbestos Inspector License number is 3303 003648) and Mary Beth Wriston (Virginia Asbestos Inspector License number is 3303 003466) on May 13-14, 2019. At your request, H&P has also incorporated previous findings from our survey and review of the adjoining H Wing into this report.
The subject site for this report is the 4th floor of Building 143 which houses patient rooms and associated medical support facilities and comprises two separate wings (H and J) and a Central Lobby section which adjoins the wings and houses the elevators that serve the floor. The survey data for the Central Lobby, H Wing and Room 117 (Storage Room) of the J Wing are included in this report.
1.0 Asbestos Sampling Procedures and Findings
The intent of the asbestos sampling was to identify asbestos containing materials (ACM) in the affected portions of the building within the Central Lobby, H Wing, and Room 117 of J Wing that could be disturbed by planned renovation work. Materials sampled included fireproofing, floor tiles and associated mastics, drywall and joint compound, ceiling plasters, ceiling tiles, piping and duct insulations and mastics and vapor barriers located below ceramic tile walls and flooring in the shower room. We note that this was a limited invasive survey of accessible materials that could be sampled without damaging surfaces and systems components. The survey areas were occupied during our site visits which limited our ability to access and sample all potential concealed materials. If materials are encountered that were not represented during this limited survey; they must be sampled and analyzed for asbestos prior to disturbance.
mailto:rholihan@besbeaufort.com mailto:ksharpless@besdesignbuild.com
The survey included collection of one hundred and seventy four (174) individual samples and layers of suspect asbestos containing materials (ACMs) that were submitted for analysis of asbestos. The suspect ACM samples were submitted to SanAir Technologies Laboratory an NVLAP accredited and Virginia licensed asbestos laboratory in Powhatan, Virginia, for analysis by Polarized Light Microscopy (PLM) following EPA Method 600/R-93/116. The analytical results are shown in the following table. Copies of the laboratory Asbestos Analysis Report and Chain of Custody forms are included as an attachment to this report.
Table I – 4th Floor H Wing and Room 117 of J Wing Building 143 Salem VAMC – Asbestos Sample Analysis
Results
Sample # Sample Location Sample Type Lab Description
Analytical Results
(Estimated %
Asbestos)
4th Floor-H Wing
61RW01 Room 110 Fire proofing Grey Fibrous None Detected
61RW02 Room 157 Duct mastic Yellow Non-Fibrous None Detected
61RW03 Room 157 Drywall White Non-Fibrous None Detected
Joint compound White Non-Fibrous None Detected
61RW04 Room 103A Ceiling tile White Fibrous None Detected
61RW05 Room 103A Window frame caulk White Non-Fibrous None Detected
61RW06 Room 103A Cove base mastic White Non-Fibrous None Detected
61RW07
Room 103 Bathroom
Plaster ceiling base coat
White Non-Fibrous None Detected
Plaster ceiling skim coat
White Non-Fibrous None Detected
61RW08 Room 104
Patch material on piping-wrap
Tan Fibrous None Detected
Patch material on piping-insulation
Yellow Fibrous None Detected
61RW09 Room 113 White duct wrap Tan Fibrous None Detected
Duct insulation Yellow Fibrous None Detected
61RW10 Nurses’ Station Textured ceiling tile White Fibrous None Detected
61RW11 Room 127 Drywall White Non-Fibrous None Detected
Joint compound White Non-Fibrous None Detected
61RW12 Room 127 White ceiling tile
(hard) White Non-Fibrous None Detected
61RW13 Room 127
Sealant on wall around piping
Grey Non-Fibrous None Detected
Wrap Various Fibrous None Detected
61RW14 Room 127
12’’ White with grey streaks floor tile White Non-Fibrous None Detected
Mastic Black Non-Fibrous None Detected
Sample # Sample Location Sample Type Lab Description
Analytical Results
(Estimated %
Asbestos)
61RW15 Room 131
Yellow mastic on pipe
Off-White Non- Fibrous
None Detected
Pipe wrap Various Fibrous None Detected
Pipe insulation Brown Fibrous None Detected
61RW16 Room 131 12’’ Pink floor tile Pink Non-Fibrous None Detected
Mastic Black Non-Fibrous None Detected
61RW17 Hallway
12’’ Pink floor tile Pink Non-Fibrous None Detected
Mastic Black Non-Fibrous None Detected
Leveling compound Off-White Non-
Fibrous None Detected
61RW18 Hallway
12’’ Pink floor tile Pink Non-Fibrous None Detected
Mastic Black Non-Fibrous None Detected
Leveling compound Off-White Non-
Fibrous None Detected
61RW19 Break Room 12’’ Brown floor tile White Non-Fibrous None Detected
Mastic Yellow Non-Fibrous None Detected
61RW20 Mechanical Room
White duct mastic White Non-Fibrous None Detected
White duct wrap Various Fibrous None Detected
White duct glue Brown Non-Fibrous None Detected
White duct insulation
Yellow Fibrous None Detected
61RW21 Mechanical Room
Glycol line mastic White Non-Fibrous None Detected
Wrap Various Fibrous None Detected
Insulation Yellow Fibrous None Detected
61RW22 Mechanical Room Brown duct mastic on metal duct Brown Non-Fibrous None Detected
61RW23 Mechanical Room
Chilled water supply line mastic
Off-White Non- Fibrous
None Detected
Wrap Various Fibrous None Detected
Insulation Yellow Fibrous None Detected
61RW24 Mechanical Room
Line mastic at Unit
143-JC-4H1
White Non-Fibrous None Detected
Wrap Various Fibrous None Detected
Insulation Yellow Fibrous None Detected
61RW25 Mechanical Room White duct mastic Various Fibrous None Detected
Insulation Yellow Fibrous None Detected
61RW26 Mechanical Room Chilled water supply elbow
Grey Non-Fibrous None Detected
61RW27 Room 136 Drywall White Non-Fibrous None Detected
Joint compound White Non-Fibrous None Detected
4th Floor-J Wing-Room 117 (Storage Room) Flooring
Analytical Results
(Estimated %
Asbestos)
61RW28 Room 117
Top layer of flooring-tile
Grey Non-Fibrous None Detected
Felt layer Off-White Fibrous None Detected
Mortar Grey Non-Fibrous None Detected
61RW29 Room 117 Bottom layer of flooring Tan Non-Fibrous None Detected
None Detected: No Asbestos Detected
Table II –Central Elevator Lobby between H and J Wings Building 143 Salem VAMC – Asbestos Sample
Analysis Results
Sample # Sample Location Sample Type Lab Description
Analytical Results
(Estimated %
Asbestos)
4th Floor-Central Lobby
513MB01 Room 4J-144 Fireproofing Grey Fibrous None Detected
513MB02 Room 4J-144
Drywall White Non-Fibrous None Detected
Joint compound White Non-Fibrous None Detected
Texture White Non-Fibrous None Detected
513MB03 Room 4J-144 Seam tape on metal ductwork White Non-Fibrous None Detected
513MB04 Room 4J-144 2X4 White fissured ceiling tile White Fibrous None Detected
513MB05 Room 4J-144
Duct insulation Yellow Fibrous None Detected
Duct wrap White Non-Fibrous None Detected
Duct mastic Off-White Non-
Fibrous None Detected
513MB06 Room 4J-144 Pipe insulation jacket adhesive
White Fibrous None Detected
513MB07 Room 4J-144 Carpet mastic Tan Non-Fibrous None Detected
513MB08 Room 4J-144 4’’ Gray cove base mastic Cream Non-Fibrous None Detected
513MB09 Corridor C4-3 2’’ pipe wrap White Fibrous None Detected
513MB10 Corridor C4-3 4’’ pipe wrap White Fibrous None Detected
513MB11 Corridor C4-3 2X4 Brown backed fissured ceiling tile
White Fibrous None Detected
513MB12 Room 4J-102
12’’ White with gray streaks floor tile White Non-Fibrous None Detected
Floor tile mastic Black Non-Fibrous None Detected
513MB13 Room 4J-101 Pipe insulation Yellow Fibrous None Detected
Pipe wrap White Fibrous None Detected
Analytical Results
(Estimated %
Asbestos)
Pipe mastic Off-White Non-
Fibrous None Detected
513MB14 Room 4J-101 Mastic on metal
HVAC duct seams Grey Non-Fibrous None Detected
513MB15 Room 4J-101 Ceramic tile adhesive Off-White Non-
Fibrous None Detected
Ceramic tile texture White Non-Fibrous None Detected
513MB16 Room 4J-100 Beige duct wrap Various Fibrous None Detected
Beige duct mastic Off-White Non-
Fibrous None Detected
513MB17 Room 4J-100 Drywall Grey Non-Fibrous None Detected
Joint compound White Non-Fibrous None Detected
513MB18 Corridor C4-1 Pipe wrap Various Fibrous None Detected
Pipe mastic Off-White Non-
Fibrous None Detected
513MB19 Corridor C4-1 Fireproofing Grey Fibrous None Detected
513MB20 Corridor C4-1
12’’ White with gray streaks floor tile White Non-Fibrous None Detected
Tile mastic Yellow Non-Fibrous None Detected
513MB21 Corridor C4-1 12’’ Green floor tile Green Non-Fibrous None Detected
Tile mastic Black Non-Fibrous None Detected
513MB22 Corridor C4-1
12’’ White with gray streaks floor tile Grey Non-Fibrous None Detected
Tile mastic Black Non-Fibrous None Detected
Leveling compound White Non-Fibrous None Detected
513MB23 Room 4J-151 Carpet mastic Blue Non-Fibrous None Detected
513MB24 Room 4J-151 4’’ Gray cove base mastic Cream Non-Fibrous None Detected
513MB25
Room 4J-148/4J-
Brown flooring Brown Non-Fibrous None Detected
Floor mastic Grey Non-Fibrous None Detected
513MB26
Room 4J-148/4J-
6’’ Gray cove base mastic Cream Non-Fibrous None Detected
513MB27 Room 4J-147 Drywall White Non-Fibrous None Detected
Joint compound White Non-Fibrous None Detected
513MB28 Room 4J-152 2X4 Plain ceiling tile Grey Non-Fibrous None Detected
513MB29
Bathroom in Room 4J-150
Drywall Grey Non-Fibrous None Detected
Joint compound White Non-Fibrous None Detected
Texture White Non-Fibrous None Detected
513MB30
Shower in Room
4J-150 Ceiling-plaster Grey Non-Fibrous None Detected
Ceiling-skim coat White Non-Fibrous None Detected
Analytical Results
(Estimated %
Asbestos)
Ceiling-texture White Non-Fibrous None Detected
513MB31 Room 4J-145 2X4 Fissured ceiling tile White Fibrous None Detected
513MB32 Room 4J-145
Drywall Grey Non-Fibrous None Detected
Joint compound White Non-Fibrous None Detected
Texture White Non-Fibrous None Detected
513MB33 Room 4J-145
12’’ White with gray streaks floor tile White Non-Fibrous None Detected
Tile mastic Black Non-Fibrous None Detected
513MB34
Service Elevator
Lobby Fireproofing Grey Fibrous None Detected
513MB35
Service Elevator
Lobby Wall tile adhesive White Non-Fibrous None Detected
513MB36 Room 4J-154 Drywall White Non-Fibrous None Detected
Joint compound White Non-Fibrous None Detected
513MB37 Room 4J-154 2X4 Hard fissured ceiling tile White Fibrous None Detected
513MB38 Room 4J-154 Fire caulking Red Non-Fibrous None Detected
513MB39 Room 4J-154 Drywall ceiling White Non-Fibrous None Detected
Joint compound White Non-Fibrous None Detected
513MB40 Room 4J-156
Drywall White Non-Fibrous None Detected
Joint compound White Non-Fibrous None Detected
Texture White Non-Fibrous None Detected
513MB41 Room 4J-153 Tan adhesive on metal ductwork
Tan Non-Fibrous None Detected
513MB42 Stairwell Flooring Black Non-Fibrous None Detected
Floor mastic Brown Non-Fibrous None Detected
513MB43 Stairwell Black cove base mastic White Non-Fibrous None Detected
513MB44 Stairwell Black stair tread Black Non-Fibrous None Detected
None Detected: No Asbestos Detected
2.0 Sample Analysis Results and Recommendations
Based on the results of analysis, asbestos was not detected in the materials sampled during this survey.
If during renovation/demolition, work is performed that will impact suspect asbestos containing materials that have not been sampled, it is recommended that these materials be sampled by a Virginia licensed asbestos inspector prior to disturbance.
2.1 Presumed Asbestos Containing Materials
During the conduct of this survey, sampling was limited to those materials which were within the areas designated by the client, which were safely accessible and which were able to be sampled without damaging systems or structures. As such, some materials that were not accessible or other not sampled should be presumed to be positive, unless sampling is conducted and shown to be negative. Such presumed asbestos containing materials (PACMS) observed at the site include, but are not limited to:
1. Fire door interiors, if present;
2. Electrical panel backing;
3. Concealed (above ceilings or within wall chases) piping or ducting insulation, if present.
4. The sample of flooring materials collected from Room 117 in the adjoining J Wing was of the ceramic flooring and underlying materials. During our surveys, this was the only ceramic floor sampled due to the other rooms being occupied and/or the potential to damage the floors in a manner that could allow for water intrusion and damage as in the case of bath and shower rooms that were still in use. Restroom and Shower Room locations within the wings and the lobby area have ceramic tile flooring with suspected vapor barriers underlying them. These other ceramic tile floors were not sampled during our surveys and as such, should be considered to have suspect asbestos containing materials underlying them. Therefore, once these rooms are no longer in use, they should be sampled for asbestos by penetration the tile and removing cores of the underlying materials prior to disturbance.
If during renovation/demolition, work is performed that will impact suspect asbestos containing materials that have not been sampled, it is recommended that these materials be sampled by a Virginia licensed asbestos inspector prior to disturbance.
If asbestos abatement activities are performed within the building, all work should be performed by a Virginia licensed asbestos abatement contractor.
3.0 EPA/NESHAP Regulations for Asbestos Containing Materials
The U.S. Environmental Protection Agency promulgated the National Emission Standards for Hazardous Air Pollutants (NESHAP) [40 CFR Part 61], which addresses the application, removal, and disposal of asbestos-containing materials (ACM). Under NESHAP the following categories are defined for asbestos-containing materials:
Friable - When dry, can be crumbled, pulverized, or reduced to powder by hand pressure.
Non-friable - When dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
Category I Non-friable ACM - Packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than 1% asbestos.
Category II Non-friable ACM – Any material, excluding Category I Non-friable ACM, which contains more than 1% asbestos.
Regulated Asbestos Containing Material (RACM) – One of the following:
1. Friable ACM
2. Category I Non-friable ACM that has become friable.
3. Category I Non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.
4. Category II Non-friable ACM that has a high probability of becoming, or has become, friable by the forces expected to act on the material in the course of demolition or renovation operations.
Under NESHAP, the following actions are required:
1. Prior to the commencement of demolition or renovation activities, the building owner must inspect the affected facility or part of the facility where the demolition or renovation activities will occur for the presence of asbestos.
2. Remove all RACM from the facility before any activity begins that would break up, dislodge, or similarly disturb the material or preclude access for subsequent removal.
3. RACM need not be removed if:
a) It is Category I non-friable ACM that is not in poor condition.
b) It is on a facility component that is encased in concrete or other similar material and is adequately wet whenever exposed.
c) It was not accessible for testing and was therefore not discovered until after demolition began and because of the demolition the material cannot be safely removed.
d) It is Category II non-friable ACM and the probability is low that the material will become crumbled, pulverized, or reduced to powder during demolition.
Note: Based on our experience, we recommend that all ACM be removed prior to renovation or demolition due to the fact that disturbance can damage them, create potential exposure to workers and occupants and make them friable. This recommendation is made as a best practice to reduce potential exposure and limit liability.
4.0 OSHA
The Occupational Safety and Health Administration (OSHA) regulates employee exposure to asbestos under 29 CFR 1926.1101 and 29 CFR 1926.1001. Work associated with known or suspect asbestos containing materials (ACM), including trace (<1%) levels of asbestos, must be conducted according to these regulations in addition to the noted EPA regulations where applicable.
If the materials that have been identified as asbestos containing will be disturbed or are in poor condition, it is recommended that the asbestos be removed by an appropriately trained and licensed asbestos abatement contractor in accordance with Virginia, EPA and OSHA regulations.
If work is performed that will impact suspect materials that have not been sampled, it is recommended that they be sampled by a Virginia licensed Asbestos Inspector prior to disturbance. We note that during renovation or demolition activities, it is not uncommon to reveal materials that were not accessible during the survey or their presence could not otherwise be known.
5.0 Lead Based Paint Testing Procedures
Testing for lead based paint was performed by sampling representative materials and components using a Niton XLp-300A X-Ray Fluorescence (XRF) Lead Paint Analyzer. The XRF contains a small radioactive source (Cadmium 109) which emits radiation when exposed to a surface. If the paint contains lead, the radiation will stimulate the lead atoms to emit characteristic x-rays, which are sensed by a detector in the unit. The XRF then converts these signals to a final reading in milligrams of lead per square centimeter of surface area tested (mg/cm2). Calibration of the Analyzer was conducted in accordance with the manufacturer’s instructions using standard reference materials with different lead concentrations. The Analyzer must indicate readings within the acceptable calibration range for the average of three readings.
If the average of the three readings is within the established tolerance, the unit is working properly.
Calibration checks were performed prior to and at the end of the testing. The XRF is able to accurately detect as little as 0.1 mg/cm2 of lead. The regulatory concentration for identifying paint film or coatings as lead based is 1.0 mg/cm², the concentration that was used as the action level for this survey. Where components tested below the designated action level of 1.0 mg/cm² for classifying the material as lead based paint; it is important to note that any painted or coated surface may contain concentrations of lead, which when disturbed, could generate lead in dust greater than the action level exposure concentration of 30 ug/m3 established by the OSHA “Lead Exposure in Construction Rule” (29 CFR 1926.62).
5.1 Lead Based Paint Testing Results
A total of one hundred sixty six (166) XRF readings, including calibrations, were collected from painted or surface coated building materials. Tested materials and components included:
Doors and door casings;
Walls;
Floors;
Windows;
Columns;
Ceilings;
Panel boxes;
Fire line;
Stair railing, riser and stringer;
Temperature pad.
5.2 Lead Based Paint Findings
The purpose of the screening survey was to identify painted surfaces and surface coatings that may contain lead at concentrations above the comparative standard for the identification of lead based paint.
Based on the results of XRF testing, lead based paint was not identified in the building materials tested.
6.0 Regulatory Compliance for Lead
H&P recommends that the contractor adhere to all applicable EPA regulations regarding disposal requirements and OSHA regulations for employee exposure.
6.1 OSHA Regulations
Where components tested below the designated action level of 1.0 mg/cm² for classifying the material as lead based paint (LBP), it is important to note that any painted or coated surface may contain concentrations of lead, which when disturbed, could generate lead in dust greater than the action level exposure concentration of 30 ug/m3 established by the OSHA “Lead Exposure in Construction Rule” (29 CFR 1926.62). The OSHA standard gives no guidance on acceptable levels of lead in coatings at which no exposure to airborne lead (above the action level) would be expected; however, OSHA defines airborne concentrations and lists specific work practices which may create a lead hazard. Therefore, personnel exposure monitoring should be performed during any removal or demolition process to establish worker exposure levels which can be used to determine appropriate personnel protection and environmental controls for the specific work practice and material type. In accordance with OSHA requirements, the Contractor performing the work will be required to conduct this monitoring.
6.2 EPA Regulations
For disposal of construction/demolition debris that have lead, the EPA requires the generator perform testing for lead content of the waste stream to determine proper disposal in accordance with the requirements of 40 CFR 261.11, Criteria for Listing Hazardous Waste.
7.0 PCB Containing Components
7.1 Methodology
During our site visit, H&P was accompanied by SVAMC facility staff who told us that just prior to our survey; they completed a lighting upgrade on the wings of the 4th floor. H&P visually reviewed accessible areas of the wings of the floor and the Central Elevator Lobby area to check for electrical transformers, gear boxes, light ballasts and other components that could contain polychlorinated biphenyls (PCBs).
7.2 Results and Recommendations
Based on our review and the understanding that a lighting upgrade had recently been completed, obvious PCB containing ballasts and other components were not observed. However based on the age of the building, there could be concealed components that could contain PCB’s that may be revealed during demolition for renovation. If encountered, the component should be reviewed and assessed prior to disturbance. If found, PCB’s should be properly disposed following all applicable local, state and federal regulations.
8.0 Mercury Containing Thermostats, Switches and other Components
8.1 Methodology
H&P visually reviewed accessible areas of the Central Lobby, H wing, and J Wing Room 117 to check for suspect mercury containing components including thermostats, switches, fluorescent lamps, mercury vapor lamps, and other components.
8.2 Results and Recommendations
H&P did not observe obvious mercury containing thermostats, switches or other components.
Fluorescent light bulbs were observed throughout the survey area that could contain mercury, including newer green capped bulbs that do contain low levels. H&P recommends that all fluorescent light bulbs be treated as mercury containing and collected for proper disposal following all applicable local, state and federal regulations. Mercury containing waste components are considered as hazardous waste materials in the Commonwealth of Virginia and should be handled accordingly.
9.0 Other Miscellaneous Materials
Medical waste collection containers are present in rooms throughout the project area. These containers should be emptied by qualified personnel and the contents disposed per established facility procedures prior to being disturbed during renovation work.
Other materials of an environmental concern that could require special handling and disposal were not observed in the areas reviewed during this survey.
10.0 Limitations
This report summarizes the results of our sample collection and analysis of the suspect ACM and lead based paint testing and review for other materials of concern based on our understanding of the requested scope of work. The findings prepared by H&P are based upon our observations and the analytical analysis of the samples collected at the time of our field inspection. The services performed were provided in accordance with generally accepted environmental industry standard practices. No warranty, expressed or implied, is made. Our observations, conclusions and recommendations are based upon conditions readily visible at the site at the time of our visit, the results of testing and analysis and information provided to us by others.
Our conclusions and recommendations are based on the guidelines presented by the EPA, Commonwealth of Virginia and OSHA. Any conditions discovered which deviate from the data contained in this report should be presented to us for our evaluation. This report has been prepared for the exclusive use of Celanese and/or their agents. This service was performed in accordance with generally accepted environmental practices. Our conclusions and recommendations are based, in part, upon information provided to us by others; we have not verified the completeness or accuracy of the information provided by others, unless otherwise noted.
During H&P’s non-invasive inspection, accessible areas were visually surveyed for the presence of ACM,.
Areas reviewed were limited to those identified by the Client and that could be readily and safely accessed. Our conclusions and recommendations are based on the results of our testing and cannot be used to form a professional opinion of conditions in other areas beyond those from which the samples were collected. It is possible that inaccessible areas, such as behind walls or above ceilings, may not have been surveyed and therefore conditions in these areas are unknown.
During this study, suspect asbestos samples were submitted for analysis at an NVLAP-accredited laboratory via polarized light microscopy. As with any similar survey of this nature, actual conditions exist only at the precise locations from which samples were collected. Certain inferences are based on the results of this sampling and related testing to form a professional opinion of conditions in areas beyond those from which the samples were collected. It is also understood that this is a limited survey so that it is possible that concealed materials may be present that were not accessible to us. No other warranty, expressed or implied, is made.
H&P assumes no responsibility regarding response actions initiated as a result of our findings; nor liability for the duties and responsibilities of the Client or building owner with respect to compliance with applicable regulations. Compliance with regulations are the responsibility of the Client or building owner in accordance with local, state, and/or federal requirements.
Closing
Should you have any questions please feel free to call me at (540) 521-1008 or via email at gwhitt@handp.com. It was a pleasure working with you on this project and I hope we can be of service to you in the future.
Sincerely, HURT & PROFFITT, INC
Gregory L. Whitt Mary Beth Wriston Environmental/Industrial Hygiene Manager Environmental/Industrial Hygiene Senior Roanoke Branch Office Roanoke Branch Office
Attachment: Analytical Results Chain of Custody Forms
XRF Data Tables Explanation of XRF Data Tables mailto:gwhitt@handp.com
APPENDIX I
Asbestos Analysis Bulk Reports
Chain of Custody Forms
SanAir ID#: 19023252
Project #: 20190443
Project Name: Building 143 4th Floor Lobby
Report Date: 5/20/2019
Analysis Report prepared for Hurt & Proffitt, Inc.
Dear Roy Wriston, We at SanAir would like to thank you for the work you recently submitted. The 44 sample(s) were received on Wednesday, May 15, 2019 via FedEx. The final report(s) is enclosed for the following sample(s): 513MB01, 513MB02, 513MB03, 513MB04, 513MB05, 513MB06, 513MB07, 513MB08, 513MB09, 513MB10, 513MB11, 513MB12, 513MB13, 513MB14, 513MB15, 513MB16, 513MB17, 513MB18, 513MB19, 513MB20, 513MB21, 513MB22, 513MB23, 513MB24, 513MB25, 513MB26, 513MB27, 513MB28, 513MB29, 513MB30, 513MB31, 513MB32, 513MB33, 513MB34, 513MB35, 513MB36, 513MB37, 513MB38, 513MB39, 513MB40, 513MB41, 513MB42, 513MB43, 513MB44.
These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information
Sample conditions:
- 44 samples in Good condition.
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20190443Project Number:
20190443P.O. Number:
Project Name: Building 143 4th Floor Lobby
5/13/2019Collected Date:
5/15/2019 9:40:00 AMReceived Date:
5/20/2019 11:02:50 AM
19023252 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
434-841-3893 (c)Phone:
Analyst: Moore, Brandi
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
513MB01 / 19023252-001
Fireproofing/ Room 4J-144
Grey Fibrous
Homogeneous
80% Min. Wool 20% Other None Detected
513MB02 / 19023252-002
Wall/ Room 4J-144, Drywall
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
513MB02 / 19023252-002
Wall/ Room 4J-144, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB02 / 19023252-002
Wall/ Room 4J-144, Texture
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB03 / 19023252-003
Duct/ Room 4J-144
White Non-Fibrous
Heterogeneous
25% Cellulose 75% Other None Detected
513MB04 / 19023252-004
Ceiling Tile/ Room 4J-144
White Fibrous
Homogeneous
40% Cellulose 40% Glass
20% Other None Detected
513MB05 / 19023252-005
Duct/ Room 4J-144, Insulation
Yellow Fibrous
Homogeneous
98% Glass 2% Other None Detected
513MB05 / 19023252-005
Duct/ Room 4J-144, Wrap
White Non-Fibrous
Heterogeneous
30% Cellulose 10% Glass
60% Other None Detected
513MB05 / 19023252-005
Duct/ Room 4J-144, Mastic
Off-White Non-Fibrous
Homogeneous
3% Wollastonite 97% Other None Detected
513MB06 / 19023252-006
Pipe/ Room 4J-144
White Fibrous
Heterogeneous
50% Cellulose 10% Glass
40% Other None Detected
Analyst:
Analysis Date: 5/20/2019 Date: 5/20/2019
Approved Signatory:
20190443Project Number:
20190443P.O. Number:
Project Name: Building 143 4th Floor Lobby
5/13/2019Collected Date:
5/15/2019 9:40:00 AMReceived Date:
5/20/2019 11:02:50 AM
19023252 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
513MB07 / 19023252-007
Carpet Mastic/ Room 4J-144
Tan Non-Fibrous
Heterogeneous
100% Other None Detected
513MB08 / 19023252-008
Cove Base Mastic/ Room 4J-144
Cream Non-Fibrous
Homogeneous
100% Other None Detected
513MB09 / 19023252-009
2" Pipe/ Corridor By Room 4J-102
White Fibrous
Heterogeneous
50% Cellulose 10% Glass
40% Other None Detected
513MB10 / 19023252-010
4" Pipe/ Corridor By Room 4J-102
White Fibrous
Heterogeneous
50% Cellulose 10% Glass
40% Other None Detected
513MB11 / 19023252-011
Ceiling Tile/ Corridor By Room 4J-102
White Fibrous
Homogeneous
40% Cellulose 40% Glass
20% Other None Detected
513MB12 / 19023252-012
12" Floor Tile/ Room 4J-102, Floor Tile
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB12 / 19023252-012
12" Floor Tile/ Room 4J-102, Mastic
Black Non-Fibrous
Homogeneous
100% Other None Detected
513MB13 / 19023252-013
Pipe/ Room 4J-101, Insulation
Yellow Fibrous
Homogeneous
98% Glass 2% Other None Detected
513MB13 / 19023252-013
Pipe/ Room 4J-101, Wrap
White Fibrous
Heterogeneous
60% Cellulose 10% Glass
30% Other None Detected
513MB13 / 19023252-013
Pipe/ Room 4J-101, Mastic
Off-White Non-Fibrous
Homogeneous
3% Wollastonite 97% Other None Detected
Analyst:
Analysis Date: 5/20/2019 Date: 5/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20190443Project Number:
20190443P.O. Number:
Project Name: Building 143 4th Floor Lobby
5/13/2019Collected Date:
5/15/2019 9:40:00 AMReceived Date:
5/20/2019 11:02:50 AM
19023252 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
513MB14 / 19023252-014
Duct/ Room 4J-101
Grey Non-Fibrous
Homogeneous
100% Other None Detected
513MB15 / 19023252-015
Ceramic Tile Adhesive/ Room 4J-101, Adhesive
Off-White Non-Fibrous
Homogeneous
100% Other None Detected
513MB15 / 19023252-015
Ceramic Tile Adhesive/ Room 4J-101, Texture
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB16 / 19023252-016
Duct/ Room 4J-100, Wrap
Various Fibrous
Heterogeneous
50% Cellulose 10% Glass
40% Other None Detected
513MB16 / 19023252-016
Duct/ Room 4J-100, Mastic
Off-White Non-Fibrous
Homogeneous
3% Wollastonite 97% Other None Detected
513MB17 / 19023252-017
Wall/ Room 4J-100, Drywall
Grey Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
513MB17 / 19023252-017
Wall/ Room 4J-100, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB18 / 19023252-018
Pipe/ Corridor By Main Elevators, Wrap
Various Fibrous
Heterogeneous
60% Cellulose 10% Glass
30% Other None Detected
513MB18 / 19023252-018
Pipe/ Corridor By Main Elevators, Mastic
Off-White Non-Fibrous
Homogeneous
3% Wollastonite 97% Other None Detected
513MB19 / 19023252-019
Fireproofing/ Corridor By Main Elevators
Grey Fibrous
Homogeneous
80% Min. Wool 20% Other None Detected
Analyst:
Analysis Date: 5/20/2019 Date: 5/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20190443Project Number:
20190443P.O. Number:
Project Name: Building 143 4th Floor Lobby
5/13/2019Collected Date:
5/15/2019 9:40:00 AMReceived Date:
5/20/2019 11:02:50 AM
19023252 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
513MB20 / 19023252-020
12" Floor Tile/ Corridor By Main Elevators, Floor Tile
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB20 / 19023252-020
12" Floor Tile/ Corridor By Main Elevators, Mastic
Yellow Non-Fibrous
Homogeneous
100% Other None Detected
513MB21 / 19023252-021
12" Floor Tile/ Corridor By Main Elevators, Floor Tile
Green Non-Fibrous
Homogeneous
100% Other None Detected
513MB21 / 19023252-021
12" Floor Tile/ Corridor By Main Elevators, Mastic
Black Non-Fibrous
Homogeneous
100% Other None Detected
513MB22 / 19023252-022
12" Floor Tile/ Corridor By Main Elevators, Floor Tile
Grey Non-Fibrous
Homogeneous
100% Other None Detected
513MB22 / 19023252-022
12" Floor Tile/ Corridor By Main Elevators, Mastic
Black Non-Fibrous
Homogeneous
100% Other None Detected
513MB22 / 19023252-022
12" Floor Tile/ Corridor By Main Elevators, Leveling Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB23 / 19023252-023
Carpet Mastic/ Room 4J-151
Blue Non-Fibrous
Heterogeneous
100% Other None Detected
513MB24 / 19023252-024
Cove Base Mastic/ Room 4J-151
Cream Non-Fibrous
Homogeneous
100% Other None Detected
513MB25 / 19023252-025
Flooring/ Room 4J-148/ 4J-149, Flooring
Brown Non-Fibrous
Heterogeneous
100% Other None Detected
Analyst:
Analysis Date: 5/20/2019 Date: 5/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20190443Project Number:
20190443P.O. Number:
Project Name: Building 143 4th Floor Lobby
5/13/2019Collected Date:
5/15/2019 9:40:00 AMReceived Date:
5/20/2019 11:02:50 AM
19023252 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
513MB25 / 19023252-025
Flooring/ Room 4J-148/ 4J-149, Mastic
Grey Non-Fibrous
Homogeneous
100% Other None Detected
513MB26 / 19023252-026
Cove Base Mastic/ Room 4J-148/ 4J-149
Cream Non-Fibrous
Homogeneous
100% Other None Detected
513MB27 / 19023252-027
Wall/ Room 4J-152, Drywall
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
513MB27 / 19023252-027
Wall/ Room 4J-152, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB28 / 19023252-028
Ceiling Tile/ Room 4J-152
Grey Non-Fibrous
Homogeneous
10% Cellulose 90% Other None Detected
513MB29 / 19023252-029
Wall/ Bathroom In Room 4J-150, Drywall
Grey Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
513MB29 / 19023252-029
Wall/ Bathroom In Room 4J-150, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB29 / 19023252-029
Wall/ Bathroom In Room 4J-150, Texture
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB30 / 19023252-030
Ceiling/ Shower In Room 4J-150, Plaster
Grey Non-Fibrous
Homogeneous
100% Other None Detected
513MB30 / 19023252-030
Ceiling/ Shower In Room 4J-150, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
Analyst:
Analysis Date: 5/20/2019 Date: 5/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20190443Project Number:
20190443P.O. Number:
Project Name: Building 143 4th Floor Lobby
5/13/2019Collected Date:
5/15/2019 9:40:00 AMReceived Date:
5/20/2019 11:02:50 AM
19023252 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
513MB30 / 19023252-030
Ceiling/ Shower In Room 4J-150, Texture
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB31 / 19023252-031
Ceiling Tile/ Room 4J-145
White Fibrous
Homogeneous
40% Cellulose 40% Glass
20% Other None Detected
513MB32 / 19023252-032
Wall/ Room 4J-145, Drywall
Grey Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
513MB32 / 19023252-032
Wall/ Room 4J-145, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB32 / 19023252-032
Wall/ Room 4J-145, Texture
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB33 / 19023252-033
12" Floor Tile/ Room 4J-145, Floor Tile
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB33 / 19023252-033
12" Floor Tile/ Room 4J-145, Mastic
Black Non-Fibrous
Homogeneous
100% Other None Detected
513MB34 / 19023252-034
Fireproofing/ Service Elevator Entry Lobby
Grey Fibrous
Homogeneous
80% Min. Wool 20% Other None Detected
513MB35 / 19023252-035
Wall Tile Adhesive/ Hall At Room 4J-154
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB36 / 19023252-036
Wall/ Room 4J-154, Drywall
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
Analyst:
Analysis Date: 5/20/2019 Date: 5/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20190443Project Number:
20190443P.O. Number:
Project Name: Building 143 4th Floor Lobby
5/13/2019Collected Date:
5/15/2019 9:40:00 AMReceived Date:
5/20/2019 11:02:50 AM
19023252 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
513MB36 / 19023252-036
Wall/ Room 4J-154, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB37 / 19023252-037
Ceiling Tile/ Room 4J-154
White Fibrous
Homogeneous
75% Glass 25% Other None Detected
513MB38 / 19023252-038
Fire Caulking/ Room 4J-154
Red Non-Fibrous
Homogeneous
100% Other None Detected
513MB39 / 19023252-039
Ceiling/ Room 4J-154, Drywall
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
513MB39 / 19023252-039
Ceiling/ Room 4J-154, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB40 / 19023252-040
Wall/ Room 4J-156, Drywall
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
513MB40 / 19023252-040
Wall/ Room 4J-156, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB40 / 19023252-040
Wall/ Room 4J-156, Texture
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB41 / 19023252-041
Duct/ Room 4J-153
Tan Non-Fibrous
Homogeneous
100% Other None Detected
513MB42 / 19023252-042
Flooring/ Stairwell, Flooring
Black Non-Fibrous
Homogeneous
100% Other None Detected
Analyst:
Analysis Date: 5/20/2019 Date: 5/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20190443Project Number:
20190443P.O. Number:
Project Name: Building 143 4th Floor Lobby
5/13/2019Collected Date:
5/15/2019 9:40:00 AMReceived Date:
5/20/2019 11:02:50 AM
19023252 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
513MB42 / 19023252-042
Flooring/ Stairwell, Mastic
Brown Non-Fibrous
Homogeneous
100% Other None Detected
513MB43 / 19023252-043
Cove Base Mastic/ Stairwell
White Non-Fibrous
Homogeneous
100% Other None Detected
513MB44 / 19023252-044
Stair Tread/ Stairwell
Black Non-Fibrous
Homogeneous
100% Other None Detected
Analyst:
Analysis Date: 5/20/2019 Date: 5/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20190443Project Number:
20190443P.O. Number:
Project Name: Building 143 4th Floor Lobby
5/13/2019Collected Date:
5/15/2019 9:40:00 AMReceived Date:
5/20/2019 11:02:50 AM
19023252 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Disclaimer
The final report cannot be reproduced, except in full, without written authorization from SanAir.
Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Samples are held for a period of 60 days.
For NY state samples, method EPA 600/M4-82-020 is performed.
Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.
Asbestos Certifications NVLAP lab code 200870 City of Philadelphia: ALL-460 PA Department of Environmental Protection Number: 68-05397 California License Number: 2915 Colorado License Number: AL-23143 Connecticut License Number: PH-0105 Massachusetts License Number: AA000222 Maine License Number: LB-0075 New York ELAP lab ID: 11983 Rhode Island License Number: AAL-126 Texas Department of State Health Services License Number: 300440 Commonwealth of Virginia 3333000323 Washington State License Number: C989 West Virginia License Number: LT000566 Vermont License: AL166318
Revision Date: 11/30/2017
SanAir ID#: 18023648
Project #: 20180509
Project Name: 4th Floor
Report Date: 6/13/2018
Analysis Report prepared for Hurt & Proffitt, Inc.
Dear Roy Wriston, We at SanAir would like to thank you for the work you recently submitted. The 103 sample(s) were received on Wednesday, June 06, 2018 via FedEx. The final report(s) is enclosed for the following sample(s): 531RW01, 531RW02, 531RW03, 531RW04, 531RW06, 531RW07, 531RW08, 531RW09, 531RW10, 531RW11, 531RW12, 531RW13, 531RW14, 531RW15, 531RW16, 531RW17, 531RW18, 531RW19, 531RW20, 531RW21, 531RW22, 531RW23, 531RW24, 531RW25, 531RW26, 531RW27, 531RW28, 531RW29, 531RW30, 531RW31, 531RW32, 531RW33, 531RW34, 531RW35, 531RW36, 531RW37, 531RW38, 531RW39, 531RW40, 531RW41, 531RW42, 531RW43, 531RW44, 531RW45, 531RW46, 531RW47, 531RW48, 531RW49, 531RW50, 531RW51, 531RW52, 531RW53, 531RW54, 531RW55, 531RW56, 531RW57, 531RW58, 531RW59, 531RW60, 531RW61, 531RW62, 531RW63, 531RW64, 531RW65, 531RW66, 531RW67, 531RW68, 531RW69, 531RW70, 531RW71, 531RW72, 531RW73, 531RW74, 531RW75, 61RW01, 61RW02, 61RW03, 61RW04, 61RW05, 61RW06, 61RW07, 61RW08, 61RW09, 61RW10, 61RW11, 61RW12, 61RW13, 61RW14, 61RW15, 61RW16, 61RW17, 61RW18, 61RW19, 61RW20, 61RW21, 61RW22, 61RW23, 61RW24, 61RW25, 61RW26, 61RW27, 61RW28, 61RW29.
These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information
Sample conditions:
- 103 samples in Good condition.
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20180509Project Number:
20180509P.O. Number:
Project Name: 4th Floor
5/31/2018 - 6/1/2018Collected Date:
6/6/2018 10:20:00 AMReceived Date:
6/13/2018 4:29:50 PM
18023648 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Analyst: Steiner, Tara | Moore, Brandi | Fleming, Christopher | Wilson, Johnathan | Pisula, Nicholas
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
531RW01 / 18023648-001
Room 126
Grey Fibrous
Homogeneous
95% Min. Wool 5% Other None Detected
531RW02 / 18023648-002
Room 130
Grey Fibrous
Homogeneous
95% Min. Wool 5% Other None Detected
531RW03 / 18023648-003
Room 107
Grey Fibrous
Homogeneous
95% Min. Wool 5% Other None Detected
531RW04 / 18023648-004
Room 126
White Fibrous
Homogeneous
70% Cellulose 10% Glass
20% Other None Detected
531RW06 / 18023648-005
Room 107
White Fibrous
Homogeneous
60% Cellulose 20% Glass
20% Other None Detected
531RW07 / 18023648-006
Room 126, Drywall
White Non-Fibrous
Homogeneous
3% Cellulose 97% Other None Detected
531RW07 / 18023648-006
Room 126, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
531RW07 / 18023648-006
Room 126, Texture
White Non-Fibrous
Homogeneous
100% Other None Detected
531RW08 / 18023648-007
Room 130, Drywall
White Non-Fibrous
Homogeneous
3% Cellulose 97% Other None Detected
531RW08 / 18023648-007
Room 130, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
Analyst:
Analysis Date: 6/13/2018 Date: 6/13/2018
Approved Signatory:
20180509Project Number:
20180509P.O. Number:
Project Name: 4th Floor
5/31/2018 - 6/1/2018Collected Date:
6/6/2018 10:20:00 AMReceived Date:
6/13/2018 4:29:50 PM
18023648 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
531RW08 / 18023648-007
Room 130, Texture
White Non-Fibrous
Homogeneous
100% Other None Detected
531RW09 / 18023648-008
Hallway By Room 112, Drywall
White Non-Fibrous
Homogeneous
3% Cellulose 97% Other None Detected
531RW09 / 18023648-008
Hallway By Room 112, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
531RW10 / 18023648-009
Room 126, Insulation
Yellow Fibrous
Homogeneous
97% Glass 3% Other None Detected
531RW10 / 18023648-009
Room 126, Wrap
Various Fibrous
Heterogeneous
60% Cellulose 10% Glass
30% Other None Detected
531RW10 / 18023648-009
Room 126, Mastic
Beige Non-Fibrous
Homogeneous
5% Wollastonite 95% Other None Detected
531RW11 / 18023648-010
Room 125, Insulation
Yellow Fibrous
Homogeneous
97% Glass 3% Other None Detected
531RW11 / 18023648-010
Room 125, Wrap
Various Fibrous
Heterogeneous
60% Cellulose 10% Glass
30% Other None Detected
531RW11 / 18023648-010
Room 125, Mastic
Beige Non-Fibrous
Homogeneous
5% Wollastonite 95% Other None Detected
531RW12 / 18023648-011
Hallway By Room 112, Insulation
Yellow Fibrous
Homogeneous
97% Glass 3% Other None Detected
Analyst:
Analysis Date: 6/13/2018 Date: 6/13/2018
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20180509Project Number:
20180509P.O. Number:
Project Name: 4th Floor
5/31/2018 - 6/1/2018Collected Date:
6/6/2018 10:20:00 AMReceived Date:
6/13/2018 4:29:50 PM
18023648 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
531RW12 / 18023648-011
Hallway By Room 112, Mastic
White Non-Fibrous
Homogeneous
5% Wollastonite 95% Other None Detected
531RW13 / 18023648-012
Room 126
Beige Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
531RW14 / 18023648-013
Hallway By Room 112, Insulation
Yellow Fibrous
Homogeneous
97% Glass 3% Other None Detected
531RW14 / 18023648-013
Hallway By Room 112, Wrap
Various Fibrous
Heterogeneous
60% Cellulose 10% Glass
30% Other None Detected
531RW14 / 18023648-013
Hallway By Room 112, Mastic
White Non-Fibrous
Homogeneous
5% Wollastonite 95% Other None Detected
531RW15 / 18023648-014
Room 125
White Non-Fibrous
Homogeneous
100% Other None Detected
531RW16 / 18023648-015
Room 125 Bathroom, Drywall
Beige Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
531RW16 / 18023648-015
Room 125 Bathroom, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
531RW17 / 18023648-016
Room 135, Drywall
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
531RW17 / 18023648-016
Room 135, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
Analyst:
Analysis Date: 6/13/2018 Date: 6/13/2018
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax:…