Bldg._143_4th_Floor_Hazardous_Materials_Survey.pdf

PDF 3 MB Posted

Attached to
Renovate Patient Privacy Phase II Federal contract opportunity
Solicitation number
36C24623R0033
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

This document is a limited hazardous materials survey report for the 4th floor of Building 143 at the Salem Veterans Affairs Medical Center in Salem, Virginia. The report details the results of asbestos sampling conducted in the Central Elevator Lobby area and adjoining H and J Wings. One hundred seventy-four samples were collected and analyzed, with no asbestos detected in any of the materials. Presumed asbestos containing materials that were not sampled due to inaccessibility or the potential for damage include fire door interiors, concealed piping or duct insulation, and vapor barriers underlying ceramic floor tiles in restrooms. The report also summarizes EPA NESHAP regulations for asbestos containing materials and OSHA requirements for worker exposure. This survey appears to be related to the federal contract opportunity to renovate patient privacy areas in Phase II of a project at this same Veterans Affairs medical center location.

View the file

Other files for this federal contract opportunity

Other files attached to Renovate Patient Privacy Phase II, newest first.
File Type Posted
S06 36C24623R0033 0005.pdf PDF
S06 36C24623R0033 0004.pdf PDF
AMICO Patient Headwalls Submittals_BES RSP.pdf PDF
Access Controls.pdf PDF
143-P21 ZONE H 3RD. FLR. PLUMBING PLAN.pdf PDF
143 Plumbing plans.pdf PDF
143-P62 SANITARY WASTE and VENT RISER DIAGRAM.pdf PDF
143-P58 DOMESTIC WATER RISER DIAGRAM.pdf PDF
143-P57 DOMESTIC WATER RISER DIAGRAM.pdf PDF
143 Sanitary Waste and Vent plan.pdf PDF
S06 36C24623R0033 0003.pdf PDF
Cubicle Curtain Tracks.pdf PDF
Wing-H_Elec..pdf PDF
281300 Physical Access Control.pdf PDF
143-P60 DOMESTIC WATER_FIRE PROTECTION RISER DIA.pdf PDF
28 05 00.pdf PDF
143 Domestic Water Riser.pdf PDF
S05 RFI Solicitation questions for Renovate Patient Privacy Phase II.pdf PDF
143-P33 PARTIAL PLUMBING PLAN 1-4IN equal 1FT.pdf PDF
Wng H Color Board.pdf PDF
143-P61 SANITARY WASTE and VENT RISER DIAGRAM.pdf PDF
143-P59 DOMESTIC WATER RISER DIAGRAM.pdf PDF
143-P36 PARTIAL PLUMBING PLANS 1-4IN equal 1FT.pdf PDF
10 25 13.pdf PDF
143-P35 PARTIAL PLUMBING PLAN 1-4IN equal 1FT.pdf PDF
143-P55 4TH. FLR. MED GAS PLAN ZONE H.pdf PDF
S06 36C24623R0033 0002.pdf PDF
S04 Site Visit_Reno Patient Privacy Phase II 8-9-2023.pdf PDF
Vol 1B Drawing 8-1-2023.pdf PDF
Vol 2 Drawing 8-1-2023.pdf PDF
Vol 1A Drawing 8-1-2023.pdf PDF
S06 36C24623R0033 0001.pdf PDF
Vol 1-15_drawings.pdf PDF
S02 36C24623R0033.docx DOCX document
Vol 61-72_drawings.pdf PDF
Vol 46-60_drawings.pdf PDF
Vol 31-45_drawings.pdf PDF
Final CD Spec Book_Wing H.pdf PDF
Vol 16-30_drawings.pdf PDF
Show all 39

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5238 VALLEYPOINTE PARKWAY

SUITE 2B, BUILDING C

ROANOKE, VA 24019

800-242-4906 TOLL FREE

540-521-1008 MAIN

www.HandP.com

ENGINEERING • SURVEYING • PLANNING • ENVIRONMENTAL • GIS

HURT & PROFFITT

Inspired | Responsive | Trusted

May 20, 2019

BES Design/Build LLC 766 Middle Street Fairhope, Alabama 36532

Attention: Richard F. Holihan and Katie Sharples Phone: 843.522.2094

Email: rholihan@besbeaufort.com, ksharpless@besdesignbuild.com

Subject: Limited Hazardous Materials Survey Building 143, 4th Floor - Central Elevator Lobby and H Wing 1970 Roanoke Boulevard Salem, Virginia H&P Project 20190443

Mr. Holihan, Hurt & Proffitt, Inc. (H&P) was requested to conduct sampling of suspect asbestos containing materials (ACM) and lead based painted building materials and to identify potential mercury and PCB containing components in Building 143 on the 4th Floor at Salem Veterans Affairs Medical Center in Salem, Virginia.

The sampling and review of the Central Elevator Lobby area was performed by H&P representatives Roy Wriston (Virginia Asbestos Inspector License number is 3303 003648) and Mary Beth Wriston (Virginia Asbestos Inspector License number is 3303 003466) on May 13-14, 2019. At your request, H&P has also incorporated previous findings from our survey and review of the adjoining H Wing into this report.

The subject site for this report is the 4th floor of Building 143 which houses patient rooms and associated medical support facilities and comprises two separate wings (H and J) and a Central Lobby section which adjoins the wings and houses the elevators that serve the floor. The survey data for the Central Lobby, H Wing and Room 117 (Storage Room) of the J Wing are included in this report.

1.0 Asbestos Sampling Procedures and Findings

The intent of the asbestos sampling was to identify asbestos containing materials (ACM) in the affected portions of the building within the Central Lobby, H Wing, and Room 117 of J Wing that could be disturbed by planned renovation work. Materials sampled included fireproofing, floor tiles and associated mastics, drywall and joint compound, ceiling plasters, ceiling tiles, piping and duct insulations and mastics and vapor barriers located below ceramic tile walls and flooring in the shower room. We note that this was a limited invasive survey of accessible materials that could be sampled without damaging surfaces and systems components. The survey areas were occupied during our site visits which limited our ability to access and sample all potential concealed materials. If materials are encountered that were not represented during this limited survey; they must be sampled and analyzed for asbestos prior to disturbance.

mailto:rholihan@besbeaufort.com mailto:ksharpless@besdesignbuild.com

The survey included collection of one hundred and seventy four (174) individual samples and layers of suspect asbestos containing materials (ACMs) that were submitted for analysis of asbestos. The suspect ACM samples were submitted to SanAir Technologies Laboratory an NVLAP accredited and Virginia licensed asbestos laboratory in Powhatan, Virginia, for analysis by Polarized Light Microscopy (PLM) following EPA Method 600/R-93/116. The analytical results are shown in the following table. Copies of the laboratory Asbestos Analysis Report and Chain of Custody forms are included as an attachment to this report.

Table I – 4th Floor H Wing and Room 117 of J Wing Building 143 Salem VAMC – Asbestos Sample Analysis

Results

Sample # Sample Location Sample Type Lab Description

Analytical Results

(Estimated %

Asbestos)

4th Floor-H Wing

61RW01 Room 110 Fire proofing Grey Fibrous None Detected

61RW02 Room 157 Duct mastic Yellow Non-Fibrous None Detected

61RW03 Room 157 Drywall White Non-Fibrous None Detected

Joint compound White Non-Fibrous None Detected

61RW04 Room 103A Ceiling tile White Fibrous None Detected

61RW05 Room 103A Window frame caulk White Non-Fibrous None Detected

61RW06 Room 103A Cove base mastic White Non-Fibrous None Detected

61RW07

Room 103 Bathroom

Plaster ceiling base coat

White Non-Fibrous None Detected

Plaster ceiling skim coat

White Non-Fibrous None Detected

61RW08 Room 104

Patch material on piping-wrap

Tan Fibrous None Detected

Patch material on piping-insulation

Yellow Fibrous None Detected

61RW09 Room 113 White duct wrap Tan Fibrous None Detected

Duct insulation Yellow Fibrous None Detected

61RW10 Nurses’ Station Textured ceiling tile White Fibrous None Detected

61RW11 Room 127 Drywall White Non-Fibrous None Detected

Joint compound White Non-Fibrous None Detected

61RW12 Room 127 White ceiling tile

(hard) White Non-Fibrous None Detected

61RW13 Room 127

Sealant on wall around piping

Grey Non-Fibrous None Detected

Wrap Various Fibrous None Detected

61RW14 Room 127

12’’ White with grey streaks floor tile White Non-Fibrous None Detected

Mastic Black Non-Fibrous None Detected

Sample # Sample Location Sample Type Lab Description

Analytical Results

(Estimated %

Asbestos)

61RW15 Room 131

Yellow mastic on pipe

Off-White Non- Fibrous

None Detected

Pipe wrap Various Fibrous None Detected

Pipe insulation Brown Fibrous None Detected

61RW16 Room 131 12’’ Pink floor tile Pink Non-Fibrous None Detected

Mastic Black Non-Fibrous None Detected

61RW17 Hallway

12’’ Pink floor tile Pink Non-Fibrous None Detected

Mastic Black Non-Fibrous None Detected

Leveling compound Off-White Non-

Fibrous None Detected

61RW18 Hallway

12’’ Pink floor tile Pink Non-Fibrous None Detected

Mastic Black Non-Fibrous None Detected

Leveling compound Off-White Non-

Fibrous None Detected

61RW19 Break Room 12’’ Brown floor tile White Non-Fibrous None Detected

Mastic Yellow Non-Fibrous None Detected

61RW20 Mechanical Room

White duct mastic White Non-Fibrous None Detected

White duct wrap Various Fibrous None Detected

White duct glue Brown Non-Fibrous None Detected

White duct insulation

Yellow Fibrous None Detected

61RW21 Mechanical Room

Glycol line mastic White Non-Fibrous None Detected

Wrap Various Fibrous None Detected

Insulation Yellow Fibrous None Detected

61RW22 Mechanical Room Brown duct mastic on metal duct Brown Non-Fibrous None Detected

61RW23 Mechanical Room

Chilled water supply line mastic

Off-White Non- Fibrous

None Detected

Wrap Various Fibrous None Detected

Insulation Yellow Fibrous None Detected

61RW24 Mechanical Room

Line mastic at Unit

143-JC-4H1

White Non-Fibrous None Detected

Wrap Various Fibrous None Detected

Insulation Yellow Fibrous None Detected

61RW25 Mechanical Room White duct mastic Various Fibrous None Detected

Insulation Yellow Fibrous None Detected

61RW26 Mechanical Room Chilled water supply elbow

Grey Non-Fibrous None Detected

61RW27 Room 136 Drywall White Non-Fibrous None Detected

Joint compound White Non-Fibrous None Detected

4th Floor-J Wing-Room 117 (Storage Room) Flooring

Analytical Results

(Estimated %

Asbestos)

61RW28 Room 117

Top layer of flooring-tile

Grey Non-Fibrous None Detected

Felt layer Off-White Fibrous None Detected

Mortar Grey Non-Fibrous None Detected

61RW29 Room 117 Bottom layer of flooring Tan Non-Fibrous None Detected

None Detected: No Asbestos Detected

Table II –Central Elevator Lobby between H and J Wings Building 143 Salem VAMC – Asbestos Sample

Analysis Results

Sample # Sample Location Sample Type Lab Description

Analytical Results

(Estimated %

Asbestos)

4th Floor-Central Lobby

513MB01 Room 4J-144 Fireproofing Grey Fibrous None Detected

513MB02 Room 4J-144

Drywall White Non-Fibrous None Detected

Joint compound White Non-Fibrous None Detected

Texture White Non-Fibrous None Detected

513MB03 Room 4J-144 Seam tape on metal ductwork White Non-Fibrous None Detected

513MB04 Room 4J-144 2X4 White fissured ceiling tile White Fibrous None Detected

513MB05 Room 4J-144

Duct insulation Yellow Fibrous None Detected

Duct wrap White Non-Fibrous None Detected

Duct mastic Off-White Non-

Fibrous None Detected

513MB06 Room 4J-144 Pipe insulation jacket adhesive

White Fibrous None Detected

513MB07 Room 4J-144 Carpet mastic Tan Non-Fibrous None Detected

513MB08 Room 4J-144 4’’ Gray cove base mastic Cream Non-Fibrous None Detected

513MB09 Corridor C4-3 2’’ pipe wrap White Fibrous None Detected

513MB10 Corridor C4-3 4’’ pipe wrap White Fibrous None Detected

513MB11 Corridor C4-3 2X4 Brown backed fissured ceiling tile

White Fibrous None Detected

513MB12 Room 4J-102

12’’ White with gray streaks floor tile White Non-Fibrous None Detected

Floor tile mastic Black Non-Fibrous None Detected

513MB13 Room 4J-101 Pipe insulation Yellow Fibrous None Detected

Pipe wrap White Fibrous None Detected

Analytical Results

(Estimated %

Asbestos)

Pipe mastic Off-White Non-

Fibrous None Detected

513MB14 Room 4J-101 Mastic on metal

HVAC duct seams Grey Non-Fibrous None Detected

513MB15 Room 4J-101 Ceramic tile adhesive Off-White Non-

Fibrous None Detected

Ceramic tile texture White Non-Fibrous None Detected

513MB16 Room 4J-100 Beige duct wrap Various Fibrous None Detected

Beige duct mastic Off-White Non-

Fibrous None Detected

513MB17 Room 4J-100 Drywall Grey Non-Fibrous None Detected

Joint compound White Non-Fibrous None Detected

513MB18 Corridor C4-1 Pipe wrap Various Fibrous None Detected

Pipe mastic Off-White Non-

Fibrous None Detected

513MB19 Corridor C4-1 Fireproofing Grey Fibrous None Detected

513MB20 Corridor C4-1

12’’ White with gray streaks floor tile White Non-Fibrous None Detected

Tile mastic Yellow Non-Fibrous None Detected

513MB21 Corridor C4-1 12’’ Green floor tile Green Non-Fibrous None Detected

Tile mastic Black Non-Fibrous None Detected

513MB22 Corridor C4-1

12’’ White with gray streaks floor tile Grey Non-Fibrous None Detected

Tile mastic Black Non-Fibrous None Detected

Leveling compound White Non-Fibrous None Detected

513MB23 Room 4J-151 Carpet mastic Blue Non-Fibrous None Detected

513MB24 Room 4J-151 4’’ Gray cove base mastic Cream Non-Fibrous None Detected

513MB25

Room 4J-148/4J-

Brown flooring Brown Non-Fibrous None Detected

Floor mastic Grey Non-Fibrous None Detected

513MB26

Room 4J-148/4J-

6’’ Gray cove base mastic Cream Non-Fibrous None Detected

513MB27 Room 4J-147 Drywall White Non-Fibrous None Detected

Joint compound White Non-Fibrous None Detected

513MB28 Room 4J-152 2X4 Plain ceiling tile Grey Non-Fibrous None Detected

513MB29

Bathroom in Room 4J-150

Drywall Grey Non-Fibrous None Detected

Joint compound White Non-Fibrous None Detected

Texture White Non-Fibrous None Detected

513MB30

Shower in Room

4J-150 Ceiling-plaster Grey Non-Fibrous None Detected

Ceiling-skim coat White Non-Fibrous None Detected

Analytical Results

(Estimated %

Asbestos)

Ceiling-texture White Non-Fibrous None Detected

513MB31 Room 4J-145 2X4 Fissured ceiling tile White Fibrous None Detected

513MB32 Room 4J-145

Drywall Grey Non-Fibrous None Detected

Joint compound White Non-Fibrous None Detected

Texture White Non-Fibrous None Detected

513MB33 Room 4J-145

12’’ White with gray streaks floor tile White Non-Fibrous None Detected

Tile mastic Black Non-Fibrous None Detected

513MB34

Service Elevator

Lobby Fireproofing Grey Fibrous None Detected

513MB35

Service Elevator

Lobby Wall tile adhesive White Non-Fibrous None Detected

513MB36 Room 4J-154 Drywall White Non-Fibrous None Detected

Joint compound White Non-Fibrous None Detected

513MB37 Room 4J-154 2X4 Hard fissured ceiling tile White Fibrous None Detected

513MB38 Room 4J-154 Fire caulking Red Non-Fibrous None Detected

513MB39 Room 4J-154 Drywall ceiling White Non-Fibrous None Detected

Joint compound White Non-Fibrous None Detected

513MB40 Room 4J-156

Drywall White Non-Fibrous None Detected

Joint compound White Non-Fibrous None Detected

Texture White Non-Fibrous None Detected

513MB41 Room 4J-153 Tan adhesive on metal ductwork

Tan Non-Fibrous None Detected

513MB42 Stairwell Flooring Black Non-Fibrous None Detected

Floor mastic Brown Non-Fibrous None Detected

513MB43 Stairwell Black cove base mastic White Non-Fibrous None Detected

513MB44 Stairwell Black stair tread Black Non-Fibrous None Detected

None Detected: No Asbestos Detected

2.0 Sample Analysis Results and Recommendations

Based on the results of analysis, asbestos was not detected in the materials sampled during this survey.

If during renovation/demolition, work is performed that will impact suspect asbestos containing materials that have not been sampled, it is recommended that these materials be sampled by a Virginia licensed asbestos inspector prior to disturbance.

2.1 Presumed Asbestos Containing Materials

During the conduct of this survey, sampling was limited to those materials which were within the areas designated by the client, which were safely accessible and which were able to be sampled without damaging systems or structures. As such, some materials that were not accessible or other not sampled should be presumed to be positive, unless sampling is conducted and shown to be negative. Such presumed asbestos containing materials (PACMS) observed at the site include, but are not limited to:

1. Fire door interiors, if present;

2. Electrical panel backing;

3. Concealed (above ceilings or within wall chases) piping or ducting insulation, if present.

4. The sample of flooring materials collected from Room 117 in the adjoining J Wing was of the ceramic flooring and underlying materials. During our surveys, this was the only ceramic floor sampled due to the other rooms being occupied and/or the potential to damage the floors in a manner that could allow for water intrusion and damage as in the case of bath and shower rooms that were still in use. Restroom and Shower Room locations within the wings and the lobby area have ceramic tile flooring with suspected vapor barriers underlying them. These other ceramic tile floors were not sampled during our surveys and as such, should be considered to have suspect asbestos containing materials underlying them. Therefore, once these rooms are no longer in use, they should be sampled for asbestos by penetration the tile and removing cores of the underlying materials prior to disturbance.

If during renovation/demolition, work is performed that will impact suspect asbestos containing materials that have not been sampled, it is recommended that these materials be sampled by a Virginia licensed asbestos inspector prior to disturbance.

If asbestos abatement activities are performed within the building, all work should be performed by a Virginia licensed asbestos abatement contractor.

3.0 EPA/NESHAP Regulations for Asbestos Containing Materials

The U.S. Environmental Protection Agency promulgated the National Emission Standards for Hazardous Air Pollutants (NESHAP) [40 CFR Part 61], which addresses the application, removal, and disposal of asbestos-containing materials (ACM). Under NESHAP the following categories are defined for asbestos-containing materials:

Friable - When dry, can be crumbled, pulverized, or reduced to powder by hand pressure.

Non-friable - When dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

Category I Non-friable ACM - Packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than 1% asbestos.

Category II Non-friable ACM – Any material, excluding Category I Non-friable ACM, which contains more than 1% asbestos.

Regulated Asbestos Containing Material (RACM) – One of the following:

1. Friable ACM

2. Category I Non-friable ACM that has become friable.

3. Category I Non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.

4. Category II Non-friable ACM that has a high probability of becoming, or has become, friable by the forces expected to act on the material in the course of demolition or renovation operations.

Under NESHAP, the following actions are required:

1. Prior to the commencement of demolition or renovation activities, the building owner must inspect the affected facility or part of the facility where the demolition or renovation activities will occur for the presence of asbestos.

2. Remove all RACM from the facility before any activity begins that would break up, dislodge, or similarly disturb the material or preclude access for subsequent removal.

3. RACM need not be removed if:

a) It is Category I non-friable ACM that is not in poor condition.

b) It is on a facility component that is encased in concrete or other similar material and is adequately wet whenever exposed.

c) It was not accessible for testing and was therefore not discovered until after demolition began and because of the demolition the material cannot be safely removed.

d) It is Category II non-friable ACM and the probability is low that the material will become crumbled, pulverized, or reduced to powder during demolition.

Note: Based on our experience, we recommend that all ACM be removed prior to renovation or demolition due to the fact that disturbance can damage them, create potential exposure to workers and occupants and make them friable. This recommendation is made as a best practice to reduce potential exposure and limit liability.

4.0 OSHA

The Occupational Safety and Health Administration (OSHA) regulates employee exposure to asbestos under 29 CFR 1926.1101 and 29 CFR 1926.1001. Work associated with known or suspect asbestos containing materials (ACM), including trace (<1%) levels of asbestos, must be conducted according to these regulations in addition to the noted EPA regulations where applicable.

If the materials that have been identified as asbestos containing will be disturbed or are in poor condition, it is recommended that the asbestos be removed by an appropriately trained and licensed asbestos abatement contractor in accordance with Virginia, EPA and OSHA regulations.

If work is performed that will impact suspect materials that have not been sampled, it is recommended that they be sampled by a Virginia licensed Asbestos Inspector prior to disturbance. We note that during renovation or demolition activities, it is not uncommon to reveal materials that were not accessible during the survey or their presence could not otherwise be known.

5.0 Lead Based Paint Testing Procedures

Testing for lead based paint was performed by sampling representative materials and components using a Niton XLp-300A X-Ray Fluorescence (XRF) Lead Paint Analyzer. The XRF contains a small radioactive source (Cadmium 109) which emits radiation when exposed to a surface. If the paint contains lead, the radiation will stimulate the lead atoms to emit characteristic x-rays, which are sensed by a detector in the unit. The XRF then converts these signals to a final reading in milligrams of lead per square centimeter of surface area tested (mg/cm2). Calibration of the Analyzer was conducted in accordance with the manufacturer’s instructions using standard reference materials with different lead concentrations. The Analyzer must indicate readings within the acceptable calibration range for the average of three readings.

If the average of the three readings is within the established tolerance, the unit is working properly.

Calibration checks were performed prior to and at the end of the testing. The XRF is able to accurately detect as little as 0.1 mg/cm2 of lead. The regulatory concentration for identifying paint film or coatings as lead based is 1.0 mg/cm², the concentration that was used as the action level for this survey. Where components tested below the designated action level of 1.0 mg/cm² for classifying the material as lead based paint; it is important to note that any painted or coated surface may contain concentrations of lead, which when disturbed, could generate lead in dust greater than the action level exposure concentration of 30 ug/m3 established by the OSHA “Lead Exposure in Construction Rule” (29 CFR 1926.62).

5.1 Lead Based Paint Testing Results

A total of one hundred sixty six (166) XRF readings, including calibrations, were collected from painted or surface coated building materials. Tested materials and components included:

Doors and door casings;

Walls;

Floors;

Windows;

Columns;

Ceilings;

Panel boxes;

Fire line;

Stair railing, riser and stringer;

Temperature pad.

5.2 Lead Based Paint Findings

The purpose of the screening survey was to identify painted surfaces and surface coatings that may contain lead at concentrations above the comparative standard for the identification of lead based paint.

Based on the results of XRF testing, lead based paint was not identified in the building materials tested.

6.0 Regulatory Compliance for Lead

H&P recommends that the contractor adhere to all applicable EPA regulations regarding disposal requirements and OSHA regulations for employee exposure.

6.1 OSHA Regulations

Where components tested below the designated action level of 1.0 mg/cm² for classifying the material as lead based paint (LBP), it is important to note that any painted or coated surface may contain concentrations of lead, which when disturbed, could generate lead in dust greater than the action level exposure concentration of 30 ug/m3 established by the OSHA “Lead Exposure in Construction Rule” (29 CFR 1926.62). The OSHA standard gives no guidance on acceptable levels of lead in coatings at which no exposure to airborne lead (above the action level) would be expected; however, OSHA defines airborne concentrations and lists specific work practices which may create a lead hazard. Therefore, personnel exposure monitoring should be performed during any removal or demolition process to establish worker exposure levels which can be used to determine appropriate personnel protection and environmental controls for the specific work practice and material type. In accordance with OSHA requirements, the Contractor performing the work will be required to conduct this monitoring.

6.2 EPA Regulations

For disposal of construction/demolition debris that have lead, the EPA requires the generator perform testing for lead content of the waste stream to determine proper disposal in accordance with the requirements of 40 CFR 261.11, Criteria for Listing Hazardous Waste.

7.0 PCB Containing Components

7.1 Methodology

During our site visit, H&P was accompanied by SVAMC facility staff who told us that just prior to our survey; they completed a lighting upgrade on the wings of the 4th floor. H&P visually reviewed accessible areas of the wings of the floor and the Central Elevator Lobby area to check for electrical transformers, gear boxes, light ballasts and other components that could contain polychlorinated biphenyls (PCBs).

7.2 Results and Recommendations

Based on our review and the understanding that a lighting upgrade had recently been completed, obvious PCB containing ballasts and other components were not observed. However based on the age of the building, there could be concealed components that could contain PCB’s that may be revealed during demolition for renovation. If encountered, the component should be reviewed and assessed prior to disturbance. If found, PCB’s should be properly disposed following all applicable local, state and federal regulations.

8.0 Mercury Containing Thermostats, Switches and other Components

8.1 Methodology

H&P visually reviewed accessible areas of the Central Lobby, H wing, and J Wing Room 117 to check for suspect mercury containing components including thermostats, switches, fluorescent lamps, mercury vapor lamps, and other components.

8.2 Results and Recommendations

H&P did not observe obvious mercury containing thermostats, switches or other components.

Fluorescent light bulbs were observed throughout the survey area that could contain mercury, including newer green capped bulbs that do contain low levels. H&P recommends that all fluorescent light bulbs be treated as mercury containing and collected for proper disposal following all applicable local, state and federal regulations. Mercury containing waste components are considered as hazardous waste materials in the Commonwealth of Virginia and should be handled accordingly.

9.0 Other Miscellaneous Materials

Medical waste collection containers are present in rooms throughout the project area. These containers should be emptied by qualified personnel and the contents disposed per established facility procedures prior to being disturbed during renovation work.

Other materials of an environmental concern that could require special handling and disposal were not observed in the areas reviewed during this survey.

10.0 Limitations

This report summarizes the results of our sample collection and analysis of the suspect ACM and lead based paint testing and review for other materials of concern based on our understanding of the requested scope of work. The findings prepared by H&P are based upon our observations and the analytical analysis of the samples collected at the time of our field inspection. The services performed were provided in accordance with generally accepted environmental industry standard practices. No warranty, expressed or implied, is made. Our observations, conclusions and recommendations are based upon conditions readily visible at the site at the time of our visit, the results of testing and analysis and information provided to us by others.

Our conclusions and recommendations are based on the guidelines presented by the EPA, Commonwealth of Virginia and OSHA. Any conditions discovered which deviate from the data contained in this report should be presented to us for our evaluation. This report has been prepared for the exclusive use of Celanese and/or their agents. This service was performed in accordance with generally accepted environmental practices. Our conclusions and recommendations are based, in part, upon information provided to us by others; we have not verified the completeness or accuracy of the information provided by others, unless otherwise noted.

During H&P’s non-invasive inspection, accessible areas were visually surveyed for the presence of ACM,.

Areas reviewed were limited to those identified by the Client and that could be readily and safely accessed. Our conclusions and recommendations are based on the results of our testing and cannot be used to form a professional opinion of conditions in other areas beyond those from which the samples were collected. It is possible that inaccessible areas, such as behind walls or above ceilings, may not have been surveyed and therefore conditions in these areas are unknown.

During this study, suspect asbestos samples were submitted for analysis at an NVLAP-accredited laboratory via polarized light microscopy. As with any similar survey of this nature, actual conditions exist only at the precise locations from which samples were collected. Certain inferences are based on the results of this sampling and related testing to form a professional opinion of conditions in areas beyond those from which the samples were collected. It is also understood that this is a limited survey so that it is possible that concealed materials may be present that were not accessible to us. No other warranty, expressed or implied, is made.

H&P assumes no responsibility regarding response actions initiated as a result of our findings; nor liability for the duties and responsibilities of the Client or building owner with respect to compliance with applicable regulations. Compliance with regulations are the responsibility of the Client or building owner in accordance with local, state, and/or federal requirements.

Closing

Should you have any questions please feel free to call me at (540) 521-1008 or via email at gwhitt@handp.com. It was a pleasure working with you on this project and I hope we can be of service to you in the future.

Sincerely, HURT & PROFFITT, INC

Gregory L. Whitt Mary Beth Wriston Environmental/Industrial Hygiene Manager Environmental/Industrial Hygiene Senior Roanoke Branch Office Roanoke Branch Office

Attachment: Analytical Results Chain of Custody Forms

XRF Data Tables Explanation of XRF Data Tables mailto:gwhitt@handp.com

APPENDIX I

Asbestos Analysis Bulk Reports

Chain of Custody Forms

SanAir ID#: 19023252

Project #: 20190443

Project Name: Building 143 4th Floor Lobby

Report Date: 5/20/2019

Analysis Report prepared for Hurt & Proffitt, Inc.

Dear Roy Wriston, We at SanAir would like to thank you for the work you recently submitted. The 44 sample(s) were received on Wednesday, May 15, 2019 via FedEx. The final report(s) is enclosed for the following sample(s): 513MB01, 513MB02, 513MB03, 513MB04, 513MB05, 513MB06, 513MB07, 513MB08, 513MB09, 513MB10, 513MB11, 513MB12, 513MB13, 513MB14, 513MB15, 513MB16, 513MB17, 513MB18, 513MB19, 513MB20, 513MB21, 513MB22, 513MB23, 513MB24, 513MB25, 513MB26, 513MB27, 513MB28, 513MB29, 513MB30, 513MB31, 513MB32, 513MB33, 513MB34, 513MB35, 513MB36, 513MB37, 513MB38, 513MB39, 513MB40, 513MB41, 513MB42, 513MB43, 513MB44.

These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information

Sample conditions:

- 44 samples in Good condition.

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20190443Project Number:

20190443P.O. Number:

Project Name: Building 143 4th Floor Lobby

5/13/2019Collected Date:

5/15/2019 9:40:00 AMReceived Date:

5/20/2019 11:02:50 AM

19023252 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

434-841-3893 (c)Phone:

Analyst: Moore, Brandi

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

513MB01 / 19023252-001

Fireproofing/ Room 4J-144

Grey Fibrous

Homogeneous

80% Min. Wool 20% Other None Detected

513MB02 / 19023252-002

Wall/ Room 4J-144, Drywall

White Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

513MB02 / 19023252-002

Wall/ Room 4J-144, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB02 / 19023252-002

Wall/ Room 4J-144, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB03 / 19023252-003

Duct/ Room 4J-144

White Non-Fibrous

Heterogeneous

25% Cellulose 75% Other None Detected

513MB04 / 19023252-004

Ceiling Tile/ Room 4J-144

White Fibrous

Homogeneous

40% Cellulose 40% Glass

20% Other None Detected

513MB05 / 19023252-005

Duct/ Room 4J-144, Insulation

Yellow Fibrous

Homogeneous

98% Glass 2% Other None Detected

513MB05 / 19023252-005

Duct/ Room 4J-144, Wrap

White Non-Fibrous

Heterogeneous

30% Cellulose 10% Glass

60% Other None Detected

513MB05 / 19023252-005

Duct/ Room 4J-144, Mastic

Off-White Non-Fibrous

Homogeneous

3% Wollastonite 97% Other None Detected

513MB06 / 19023252-006

Pipe/ Room 4J-144

White Fibrous

Heterogeneous

50% Cellulose 10% Glass

40% Other None Detected

Analyst:

Analysis Date: 5/20/2019 Date: 5/20/2019

Approved Signatory:

20190443Project Number:

20190443P.O. Number:

Project Name: Building 143 4th Floor Lobby

5/13/2019Collected Date:

5/15/2019 9:40:00 AMReceived Date:

5/20/2019 11:02:50 AM

19023252 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

513MB07 / 19023252-007

Carpet Mastic/ Room 4J-144

Tan Non-Fibrous

Heterogeneous

100% Other None Detected

513MB08 / 19023252-008

Cove Base Mastic/ Room 4J-144

Cream Non-Fibrous

Homogeneous

100% Other None Detected

513MB09 / 19023252-009

2" Pipe/ Corridor By Room 4J-102

White Fibrous

Heterogeneous

50% Cellulose 10% Glass

40% Other None Detected

513MB10 / 19023252-010

4" Pipe/ Corridor By Room 4J-102

White Fibrous

Heterogeneous

50% Cellulose 10% Glass

40% Other None Detected

513MB11 / 19023252-011

Ceiling Tile/ Corridor By Room 4J-102

White Fibrous

Homogeneous

40% Cellulose 40% Glass

20% Other None Detected

513MB12 / 19023252-012

12" Floor Tile/ Room 4J-102, Floor Tile

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB12 / 19023252-012

12" Floor Tile/ Room 4J-102, Mastic

Black Non-Fibrous

Homogeneous

100% Other None Detected

513MB13 / 19023252-013

Pipe/ Room 4J-101, Insulation

Yellow Fibrous

Homogeneous

98% Glass 2% Other None Detected

513MB13 / 19023252-013

Pipe/ Room 4J-101, Wrap

White Fibrous

Heterogeneous

60% Cellulose 10% Glass

30% Other None Detected

513MB13 / 19023252-013

Pipe/ Room 4J-101, Mastic

Off-White Non-Fibrous

Homogeneous

3% Wollastonite 97% Other None Detected

Analyst:

Analysis Date: 5/20/2019 Date: 5/20/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20190443Project Number:

20190443P.O. Number:

Project Name: Building 143 4th Floor Lobby

5/13/2019Collected Date:

5/15/2019 9:40:00 AMReceived Date:

5/20/2019 11:02:50 AM

19023252 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

513MB14 / 19023252-014

Duct/ Room 4J-101

Grey Non-Fibrous

Homogeneous

100% Other None Detected

513MB15 / 19023252-015

Ceramic Tile Adhesive/ Room 4J-101, Adhesive

Off-White Non-Fibrous

Homogeneous

100% Other None Detected

513MB15 / 19023252-015

Ceramic Tile Adhesive/ Room 4J-101, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB16 / 19023252-016

Duct/ Room 4J-100, Wrap

Various Fibrous

Heterogeneous

50% Cellulose 10% Glass

40% Other None Detected

513MB16 / 19023252-016

Duct/ Room 4J-100, Mastic

Off-White Non-Fibrous

Homogeneous

3% Wollastonite 97% Other None Detected

513MB17 / 19023252-017

Wall/ Room 4J-100, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

513MB17 / 19023252-017

Wall/ Room 4J-100, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB18 / 19023252-018

Pipe/ Corridor By Main Elevators, Wrap

Various Fibrous

Heterogeneous

60% Cellulose 10% Glass

30% Other None Detected

513MB18 / 19023252-018

Pipe/ Corridor By Main Elevators, Mastic

Off-White Non-Fibrous

Homogeneous

3% Wollastonite 97% Other None Detected

513MB19 / 19023252-019

Fireproofing/ Corridor By Main Elevators

Grey Fibrous

Homogeneous

80% Min. Wool 20% Other None Detected

Analyst:

Analysis Date: 5/20/2019 Date: 5/20/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20190443Project Number:

20190443P.O. Number:

Project Name: Building 143 4th Floor Lobby

5/13/2019Collected Date:

5/15/2019 9:40:00 AMReceived Date:

5/20/2019 11:02:50 AM

19023252 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

513MB20 / 19023252-020

12" Floor Tile/ Corridor By Main Elevators, Floor Tile

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB20 / 19023252-020

12" Floor Tile/ Corridor By Main Elevators, Mastic

Yellow Non-Fibrous

Homogeneous

100% Other None Detected

513MB21 / 19023252-021

12" Floor Tile/ Corridor By Main Elevators, Floor Tile

Green Non-Fibrous

Homogeneous

100% Other None Detected

513MB21 / 19023252-021

12" Floor Tile/ Corridor By Main Elevators, Mastic

Black Non-Fibrous

Homogeneous

100% Other None Detected

513MB22 / 19023252-022

12" Floor Tile/ Corridor By Main Elevators, Floor Tile

Grey Non-Fibrous

Homogeneous

100% Other None Detected

513MB22 / 19023252-022

12" Floor Tile/ Corridor By Main Elevators, Mastic

Black Non-Fibrous

Homogeneous

100% Other None Detected

513MB22 / 19023252-022

12" Floor Tile/ Corridor By Main Elevators, Leveling Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB23 / 19023252-023

Carpet Mastic/ Room 4J-151

Blue Non-Fibrous

Heterogeneous

100% Other None Detected

513MB24 / 19023252-024

Cove Base Mastic/ Room 4J-151

Cream Non-Fibrous

Homogeneous

100% Other None Detected

513MB25 / 19023252-025

Flooring/ Room 4J-148/ 4J-149, Flooring

Brown Non-Fibrous

Heterogeneous

100% Other None Detected

Analyst:

Analysis Date: 5/20/2019 Date: 5/20/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20190443Project Number:

20190443P.O. Number:

Project Name: Building 143 4th Floor Lobby

5/13/2019Collected Date:

5/15/2019 9:40:00 AMReceived Date:

5/20/2019 11:02:50 AM

19023252 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

513MB25 / 19023252-025

Flooring/ Room 4J-148/ 4J-149, Mastic

Grey Non-Fibrous

Homogeneous

100% Other None Detected

513MB26 / 19023252-026

Cove Base Mastic/ Room 4J-148/ 4J-149

Cream Non-Fibrous

Homogeneous

100% Other None Detected

513MB27 / 19023252-027

Wall/ Room 4J-152, Drywall

White Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

513MB27 / 19023252-027

Wall/ Room 4J-152, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB28 / 19023252-028

Ceiling Tile/ Room 4J-152

Grey Non-Fibrous

Homogeneous

10% Cellulose 90% Other None Detected

513MB29 / 19023252-029

Wall/ Bathroom In Room 4J-150, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

513MB29 / 19023252-029

Wall/ Bathroom In Room 4J-150, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB29 / 19023252-029

Wall/ Bathroom In Room 4J-150, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB30 / 19023252-030

Ceiling/ Shower In Room 4J-150, Plaster

Grey Non-Fibrous

Homogeneous

100% Other None Detected

513MB30 / 19023252-030

Ceiling/ Shower In Room 4J-150, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 5/20/2019 Date: 5/20/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20190443Project Number:

20190443P.O. Number:

Project Name: Building 143 4th Floor Lobby

5/13/2019Collected Date:

5/15/2019 9:40:00 AMReceived Date:

5/20/2019 11:02:50 AM

19023252 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

513MB30 / 19023252-030

Ceiling/ Shower In Room 4J-150, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB31 / 19023252-031

Ceiling Tile/ Room 4J-145

White Fibrous

Homogeneous

40% Cellulose 40% Glass

20% Other None Detected

513MB32 / 19023252-032

Wall/ Room 4J-145, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

513MB32 / 19023252-032

Wall/ Room 4J-145, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB32 / 19023252-032

Wall/ Room 4J-145, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB33 / 19023252-033

12" Floor Tile/ Room 4J-145, Floor Tile

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB33 / 19023252-033

12" Floor Tile/ Room 4J-145, Mastic

Black Non-Fibrous

Homogeneous

100% Other None Detected

513MB34 / 19023252-034

Fireproofing/ Service Elevator Entry Lobby

Grey Fibrous

Homogeneous

80% Min. Wool 20% Other None Detected

513MB35 / 19023252-035

Wall Tile Adhesive/ Hall At Room 4J-154

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB36 / 19023252-036

Wall/ Room 4J-154, Drywall

White Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

Analyst:

Analysis Date: 5/20/2019 Date: 5/20/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20190443Project Number:

20190443P.O. Number:

Project Name: Building 143 4th Floor Lobby

5/13/2019Collected Date:

5/15/2019 9:40:00 AMReceived Date:

5/20/2019 11:02:50 AM

19023252 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

513MB36 / 19023252-036

Wall/ Room 4J-154, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB37 / 19023252-037

Ceiling Tile/ Room 4J-154

White Fibrous

Homogeneous

75% Glass 25% Other None Detected

513MB38 / 19023252-038

Fire Caulking/ Room 4J-154

Red Non-Fibrous

Homogeneous

100% Other None Detected

513MB39 / 19023252-039

Ceiling/ Room 4J-154, Drywall

White Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

513MB39 / 19023252-039

Ceiling/ Room 4J-154, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB40 / 19023252-040

Wall/ Room 4J-156, Drywall

White Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

513MB40 / 19023252-040

Wall/ Room 4J-156, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB40 / 19023252-040

Wall/ Room 4J-156, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB41 / 19023252-041

Duct/ Room 4J-153

Tan Non-Fibrous

Homogeneous

100% Other None Detected

513MB42 / 19023252-042

Flooring/ Stairwell, Flooring

Black Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 5/20/2019 Date: 5/20/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20190443Project Number:

20190443P.O. Number:

Project Name: Building 143 4th Floor Lobby

5/13/2019Collected Date:

5/15/2019 9:40:00 AMReceived Date:

5/20/2019 11:02:50 AM

19023252 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

513MB42 / 19023252-042

Flooring/ Stairwell, Mastic

Brown Non-Fibrous

Homogeneous

100% Other None Detected

513MB43 / 19023252-043

Cove Base Mastic/ Stairwell

White Non-Fibrous

Homogeneous

100% Other None Detected

513MB44 / 19023252-044

Stair Tread/ Stairwell

Black Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 5/20/2019 Date: 5/20/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20190443Project Number:

20190443P.O. Number:

Project Name: Building 143 4th Floor Lobby

5/13/2019Collected Date:

5/15/2019 9:40:00 AMReceived Date:

5/20/2019 11:02:50 AM

19023252 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Disclaimer

The final report cannot be reproduced, except in full, without written authorization from SanAir.

Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Samples are held for a period of 60 days.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

Asbestos Certifications NVLAP lab code 200870 City of Philadelphia: ALL-460 PA Department of Environmental Protection Number: 68-05397 California License Number: 2915 Colorado License Number: AL-23143 Connecticut License Number: PH-0105 Massachusetts License Number: AA000222 Maine License Number: LB-0075 New York ELAP lab ID: 11983 Rhode Island License Number: AAL-126 Texas Department of State Health Services License Number: 300440 Commonwealth of Virginia 3333000323 Washington State License Number: C989 West Virginia License Number: LT000566 Vermont License: AL166318

Revision Date: 11/30/2017

SanAir ID#: 18023648

Project #: 20180509

Project Name: 4th Floor

Report Date: 6/13/2018

Analysis Report prepared for Hurt & Proffitt, Inc.

Dear Roy Wriston, We at SanAir would like to thank you for the work you recently submitted. The 103 sample(s) were received on Wednesday, June 06, 2018 via FedEx. The final report(s) is enclosed for the following sample(s): 531RW01, 531RW02, 531RW03, 531RW04, 531RW06, 531RW07, 531RW08, 531RW09, 531RW10, 531RW11, 531RW12, 531RW13, 531RW14, 531RW15, 531RW16, 531RW17, 531RW18, 531RW19, 531RW20, 531RW21, 531RW22, 531RW23, 531RW24, 531RW25, 531RW26, 531RW27, 531RW28, 531RW29, 531RW30, 531RW31, 531RW32, 531RW33, 531RW34, 531RW35, 531RW36, 531RW37, 531RW38, 531RW39, 531RW40, 531RW41, 531RW42, 531RW43, 531RW44, 531RW45, 531RW46, 531RW47, 531RW48, 531RW49, 531RW50, 531RW51, 531RW52, 531RW53, 531RW54, 531RW55, 531RW56, 531RW57, 531RW58, 531RW59, 531RW60, 531RW61, 531RW62, 531RW63, 531RW64, 531RW65, 531RW66, 531RW67, 531RW68, 531RW69, 531RW70, 531RW71, 531RW72, 531RW73, 531RW74, 531RW75, 61RW01, 61RW02, 61RW03, 61RW04, 61RW05, 61RW06, 61RW07, 61RW08, 61RW09, 61RW10, 61RW11, 61RW12, 61RW13, 61RW14, 61RW15, 61RW16, 61RW17, 61RW18, 61RW19, 61RW20, 61RW21, 61RW22, 61RW23, 61RW24, 61RW25, 61RW26, 61RW27, 61RW28, 61RW29.

These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information

Sample conditions:

- 103 samples in Good condition.

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20180509Project Number:

20180509P.O. Number:

Project Name: 4th Floor

5/31/2018 - 6/1/2018Collected Date:

6/6/2018 10:20:00 AMReceived Date:

6/13/2018 4:29:50 PM

18023648 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Analyst: Steiner, Tara | Moore, Brandi | Fleming, Christopher | Wilson, Johnathan | Pisula, Nicholas

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

531RW01 / 18023648-001

Room 126

Grey Fibrous

Homogeneous

95% Min. Wool 5% Other None Detected

531RW02 / 18023648-002

Room 130

Grey Fibrous

Homogeneous

95% Min. Wool 5% Other None Detected

531RW03 / 18023648-003

Room 107

Grey Fibrous

Homogeneous

95% Min. Wool 5% Other None Detected

531RW04 / 18023648-004

Room 126

White Fibrous

Homogeneous

70% Cellulose 10% Glass

20% Other None Detected

531RW06 / 18023648-005

Room 107

White Fibrous

Homogeneous

60% Cellulose 20% Glass

20% Other None Detected

531RW07 / 18023648-006

Room 126, Drywall

White Non-Fibrous

Homogeneous

3% Cellulose 97% Other None Detected

531RW07 / 18023648-006

Room 126, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

531RW07 / 18023648-006

Room 126, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

531RW08 / 18023648-007

Room 130, Drywall

White Non-Fibrous

Homogeneous

3% Cellulose 97% Other None Detected

531RW08 / 18023648-007

Room 130, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 6/13/2018 Date: 6/13/2018

Approved Signatory:

20180509Project Number:

20180509P.O. Number:

Project Name: 4th Floor

5/31/2018 - 6/1/2018Collected Date:

6/6/2018 10:20:00 AMReceived Date:

6/13/2018 4:29:50 PM

18023648 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

531RW08 / 18023648-007

Room 130, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

531RW09 / 18023648-008

Hallway By Room 112, Drywall

White Non-Fibrous

Homogeneous

3% Cellulose 97% Other None Detected

531RW09 / 18023648-008

Hallway By Room 112, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

531RW10 / 18023648-009

Room 126, Insulation

Yellow Fibrous

Homogeneous

97% Glass 3% Other None Detected

531RW10 / 18023648-009

Room 126, Wrap

Various Fibrous

Heterogeneous

60% Cellulose 10% Glass

30% Other None Detected

531RW10 / 18023648-009

Room 126, Mastic

Beige Non-Fibrous

Homogeneous

5% Wollastonite 95% Other None Detected

531RW11 / 18023648-010

Room 125, Insulation

Yellow Fibrous

Homogeneous

97% Glass 3% Other None Detected

531RW11 / 18023648-010

Room 125, Wrap

Various Fibrous

Heterogeneous

60% Cellulose 10% Glass

30% Other None Detected

531RW11 / 18023648-010

Room 125, Mastic

Beige Non-Fibrous

Homogeneous

5% Wollastonite 95% Other None Detected

531RW12 / 18023648-011

Hallway By Room 112, Insulation

Yellow Fibrous

Homogeneous

97% Glass 3% Other None Detected

Analyst:

Analysis Date: 6/13/2018 Date: 6/13/2018

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20180509Project Number:

20180509P.O. Number:

Project Name: 4th Floor

5/31/2018 - 6/1/2018Collected Date:

6/6/2018 10:20:00 AMReceived Date:

6/13/2018 4:29:50 PM

18023648 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

531RW12 / 18023648-011

Hallway By Room 112, Mastic

White Non-Fibrous

Homogeneous

5% Wollastonite 95% Other None Detected

531RW13 / 18023648-012

Room 126

Beige Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

531RW14 / 18023648-013

Hallway By Room 112, Insulation

Yellow Fibrous

Homogeneous

97% Glass 3% Other None Detected

531RW14 / 18023648-013

Hallway By Room 112, Wrap

Various Fibrous

Heterogeneous

60% Cellulose 10% Glass

30% Other None Detected

531RW14 / 18023648-013

Hallway By Room 112, Mastic

White Non-Fibrous

Homogeneous

5% Wollastonite 95% Other None Detected

531RW15 / 18023648-014

Room 125

White Non-Fibrous

Homogeneous

100% Other None Detected

531RW16 / 18023648-015

Room 125 Bathroom, Drywall

Beige Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

531RW16 / 18023648-015

Room 125 Bathroom, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

531RW17 / 18023648-016

Room 135, Drywall

White Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

531RW17 / 18023648-016

Room 135, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 6/13/2018 Date: 6/13/2018

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax:…