About this file

This document package includes technical drawings and specifications for renovating and replacing pharmacy air handling units at the Durham Veterans Affairs Medical Center. The scope of work involves upgrading existing partitions to required fire ratings, patching walls and floors, relocating a sink unit, and installing new concrete pads and air handlers in an interstitial mechanical space. The related federal contract opportunity is solicitation number 36C24620R0152 for project Z2DZ to renovate and replace the pharmacy AHUs. The Department of Veterans Affairs Veterans Health Administration VISN 6 is listed as the agency. No further details are provided on response dates, pricing terms, or set asides.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DZ--Renovate And Replace Pharmacy AHUs, newest first.
File Type Posted
36C24620R0152 0002.docx DOCX document
RFI 22 A051.pdf PDF
RFI 15 M-701.pdf PDF
36C24620R0152 0001.docx DOCX document
RFI 10 A101A and A600.pdf PDF
Interstitial 2nd Floor.pdf PDF
A102.pdf PDF
RFI 001 Response Review VA Comments.pdf PDF
RFI 11-13 -A121A -A121B.pdf PDF
RFI 05 A122.pdf PDF
RFI 19 -20 MH Sheets.pdf PDF
RFI 16 -17 - 18- M-001.pdf PDF
RFI 12 A600.pdf PDF
Past Performance Questionnaire.pdf PDF
36C24620R0152_3.docx DOCX document
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

POTENTIAL AREA FOR ACCESS TO

INTERSTITIAL SPACE FROM

EXTERIOR SOUTH FACADE

FACING ERWIN STREET FOR

INSTALLATION OF HVAC

MATERIALS AND EQUIPMENT

Attachment 2

F2122

F2121

MECH WALK-ON CEILING

MECH WALK-ON CEILING

1. THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL

DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES

PRIOR TO NEW STUD INSTALLATION.

2. ALL WALL HUNG ITEMS OR EQUIPMENT PROVIDED BY THE

OWNER OR GENERAL CONTRACTOR SHALL HAVE FIRE TREATED

WOOD BLOCKING WHERE REQUIRED.

3. THE GENERAL CONTRACTOR IS TO FIELD VERIFY THE INTEGRITY

AND PENETRATIONS OF ALL EXISTING RATED PARTITIONS TO

REMAIN COMPLIANT WITH THE LIFE SAFETY PLANS.

4. WHERE NEW WORK IS LIMITED TO A PORTION OF A WALL,

REFINISH ENTIRE WALL TO MATCH EXISTING TO NEAREST

CORNER OR MATERIAL TRANSITION.

1. UPGRADE EXISTING PARTITIONS TO RATING SHOWN ON LIFE

SAFETY PLAN.

2. PTM EXISTING WALL AS REQUIRED.

3. PTM EXTERIOR WALL AS REQUIRED FROM REMOVAL OF

WINDOWS.

4. GC TO CONFIRM EXISTING PARTITION MEETS RATING

SPECIFIED ON LIFE SAFETY PLAN. SEAL ALL PENETRATIONS

AND EXTEND WALLS TO DECK ABOVE AS REQUIRED.

5. RELOCATED SINK UNIT.

6. PTM FLOORING & BASE AS RQD.

PROPOSED LOCATION FOR

NEW AIR HANDLER UNITS.

SEE MEP DRAWINGS.

NEW CONCRETE PAD. SEE

STRUCTURAL DRAWINGS.

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management

558-17-233

Durham VAMC Durham NC

REPLACE PHARMACY AHUS

RENOVATE F1204 & N1004

COMPOUNDING PHARMACIES

102 THIRD AVENUE NORTHEAST

HICKORY, NORTH CAROLINA 28601

PHONE: 828.315.9962

NC ENGINEERING LICENSE NO: P-0214

NC ARCHITECTURE LICENSE NO: 51254

o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

CHARLOTTE | 704.295.4263

705 EAST MOREHEAD STREET, 28202

NC License No: C 2848 AME Project No: 18104

VA FORM 08-6231

NOT FOR

CONSTRUCTION

60% SUBMISSION

F

E

D

C

B

A

A122 Designer Checker

FLOOR PLAN - LEVEL 02 - INTERSTITIAL

MECHANICAL SPACE

60% SUBMISSION - NOT FOR CONSTRUCTION

FEBRUARY 19, 2019

FEBRUARY 19, 2019

FLOOR PLAN GENERAL NOTES

FLOOR PLAN KEYED NOTES

1/4" = 1'-0"F1 FLR - LEVEL 02 - INTERSTITIAL MECHANICAL SPACE

Attachment 2 pbrigham Text Box

ERWIN STREET

pbrigham Text Box

~ LOCATION OF NEW AHU

pbrigham Rectangle

VA246-13-D-0103 VA246-17-J-7273 558-17-233 DurVAHCS Replace Pharmacy AHUs-RFI S-4
A9Ry722dx_8bwgfp_3lc

File details come from the government source that posted it. Updated .