RFI 11-13 -A121A -A121B.pdf
PDF 416 KB Posted
- Attached to
- Z2DZ--Renovate And Replace Pharmacy AHUs Federal contract opportunity
- Solicitation number
- 36C24620R0152
About this file
This solicitation package includes construction drawings and specifications for renovations and replacement of pharmacy air handling units at a Department of Veterans Affairs medical center. Key details of the solicitation include specifications for demolition of existing spaces F1204 and N1004 to prepare for new construction, installation of new mechanical systems including AHUs on the first and second floors, and finishes for the renovated pharmacy and oncology areas. The solicitation also provides floor plans, exterior elevations, and sections detailing requirements for the scope of work. Responses to this solicitation from the Department of Veterans Affairs Veterans Health Administration VISN 6 are due based on the published timeline.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24620R0152 0002.docx | DOCX document | |
| RFI 10 A101A and A600.pdf | ||
| Interstitial 2nd Floor.pdf | ||
| A102.pdf | ||
| RFI 001 Response Review VA Comments.pdf | ||
| RFI 22 A051.pdf | ||
| RFI 15 M-701.pdf | ||
| 36C24620R0152 0001.docx | DOCX document | |
| RFI 05 A122.pdf | ||
| RFI 25 Attachment 2.pdf | ||
| RFI 19 -20 MH Sheets.pdf | ||
| RFI 16 -17 - 18- M-001.pdf | ||
| RFI 12 A600.pdf | ||
| Past Performance Questionnaire.pdf | ||
| 36C24620R0152_3.docx | DOCX document |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F
F
F F
F
FR
FR
LOCKER/BREAK
ROOM
F1217
UNIT DOSE
MEDS
NURSING HOME
SUPPORT
CART FILLING
OUTPATIENT
FILLING
SCRIPT PRO
ROBOT
MEDICATION
STORAGE
MAIL CHECK &
PACKAGING
INVESTIGATIONAL
DRUG
STORAGE
CART FILLING
OUTPATIENT
PICKUP
134 SF
HAZARDOUS
STORAGE
F1204J
76 SF
OFFICE
F1217C
184 SF
NON HAZARDOUS
COMPOUNDING
F1204M
285 SF
STERILE
STORAGE
F1204N
237 SF
ANTE ROOM
F1204K
164 SF
HAZARDOUS
COMPOUNDING
F1204L
128 SF
OMNICELL/795
AREA
F1204D
77 SF
SHARED OFFICE
F1217B
NON STERILE
STORAGE
F1204X
F1
4M X
F1204KX
F1
4L X
F1204JX
F1
7C X
F1204DX
B A
F1
7B X
TOILET
F1204C
CONTROLLED
SUBSTANCES
VAULT
F1204E
OUTPATIENT
STAFF WORK
ROOM
F1204G
OFFICE, SECY
F1206
OFFICE
F1208
OFFICE
F1210
OFFICE
PHARMACIST
F1212
OFFICE
F1214
CONFERENCE
ROOM
F1217A
OFFICE
F1206A
ELECTRICAL
CLOSET
F1213
5'-9 1/8"
F7 A121A
6'-2"
4' -0
'-1
/4
'-5
/4
'-6
/8
'-1
1/ 4"
3' -0
/8
8'
-5
/4
8' -1
3/
4"
10'-5 1/4" 9'-4 3/8"
4'-5 1/4"
2'-5 1/4"
1' -1
1/
4"6' -1
/2
1'
-1
5/ 8"
4'-0"
15'-9 1/4"
HSK
F1204B
UNASSIGNED
F5 A5 00 1'-0"
ETR
1'-0"
R 11"
1. THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL
DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES
PRIOR TO NEW STUD INSTALLATION.
2. ALL WALL HUNG ITEMS OR EQUIPMENT PROVIDED BY THE
OWNER OR GENERAL CONTRACTOR SHALL HAVE FIRE TREATED
WOOD BLOCKING WHERE REQUIRED.
3. THE GENERAL CONTRACTOR IS TO FIELD VERIFY THE INTEGRITY
AND PENETRATIONS OF ALL EXISTING RATED PARTITIONS TO
REMAIN COMPLIANT WITH THE LIFE SAFETY PLANS.
4. WHERE NEW WORK IS LIMITED TO A PORTION OF A WALL,
REFINISH ENTIRE WALL TO MATCH EXISTING TO NEAREST
CORNER OR MATERIAL TRANSITION.
1. UPGRADE EXISTING PARTITIONS TO RATING SHOWN ON LIFE
SAFETY PLAN.
2. PTM EXISTING WALL AS REQUIRED.
3. PTM EXTERIOR WALL AS REQUIRED FROM REMOVAL OF
WINDOWS.
4. GC TO CONFIRM EXISTING PARTITION MEETS RATING
SPECIFIED ON LIFE SAFETY PLAN. SEAL ALL PENETRATIONS
AND EXTEND WALLS TO DECK ABOVE AS REQUIRED.
5. RELOCATED SINK UNIT.
6. PTM FLOORING & BASE AS RQD.
7. PTM WALL AS RQD.
8. REPLACE CEMENTITIOUS PANELS AT EXTERIOR.
9. MODULAR FURNITURE PROVIDED & INSTALLED BY OWNER.
10. ACCENT FLOORING TO CREATE AREA OF DEMARCATION.
11. REINSTALL EXISTING LOUVERS UPON COMPLETION OF
MECHANICAL EQUIPMENT INSTALLATION.
12. NEW VCT FLOORING TO TIE INTO EXISTING.
13. NEW EPOXY COATING ON CONCRETE PAD
LEVEL 01
0' - 0"
V.
I.F
2'
-1 0"
V.
I.F
5'
-4
/8
NEW BRICK WORK TO
MATCH EXISTING.
NEW VAPOR BARRIER TO
MATCH EXISTING & OVERLAP
W/ EXISTING 8" MINIMUM.
5/8" GYPSUM SHEATHING
6" METAL STUD WALL
INSTALLED IN OLD
WINDOW OPENING
5/8" GWB.
BATT INSULATION
M
IN
8"
M
IN
8"
ETR. LINTEL
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C‐2848 AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
PLAN NORTH TRUE NORTH A121A
MJCSEC
FLOOR PLAN - LEVEL 01 - F1204
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020 June 30, 2020
1/4" = 1'-0"F1 FLR - LEVEL 01 - NEW F1204 PHARMACY
FLOOR PLAN GENERAL NOTES
FLOOR PLAN KEYED NOTES
3/4" = 1'-0"F7 SECTION @ F1204 WALL INFILL
1 Addendum 1 11/12/2020
LY
F
F F
F
N
SDSD
F
SD
SD
SD
SD
SD
FR
1. THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL
DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES
PRIOR TO NEW STUD INSTALLATION.
2. ALL WALL HUNG ITEMS OR EQUIPMENT PROVIDED BY THE
OWNER OR GENERAL CONTRACTOR SHALL HAVE FIRE TREATED
WOOD BLOCKING WHERE REQUIRED.
3. THE GENERAL CONTRACTOR IS TO FIELD VERIFY THE INTEGRITY
AND PENETRATIONS OF ALL EXISTING RATED PARTITIONS TO
REMAIN COMPLIANT WITH THE LIFE SAFETY PLANS.
4. WHERE NEW WORK IS LIMITED TO A PORTION OF A WALL,
REFINISH ENTIRE WALL TO MATCH EXISTING TO NEAREST
CORNER OR MATERIAL TRANSITION.
1. UPGRADE EXISTING PARTITIONS TO RATING SHOWN ON LIFE
SAFETY PLAN.
2. PTM EXISTING WALL AS REQUIRED.
3. PTM EXTERIOR WALL AS REQUIRED FROM REMOVAL OF
WINDOWS.
4. GC TO CONFIRM EXISTING PARTITION MEETS RATING
SPECIFIED ON LIFE SAFETY PLAN. SEAL ALL PENETRATIONS
AND EXTEND WALLS TO DECK ABOVE AS REQUIRED.
5. RELOCATED SINK UNIT.
6. PTM FLOORING & BASE AS RQD.
7. PTM WALL AS RQD.
8. REPLACE CEMENTITIOUS PANELS AT EXTERIOR.
9. MODULAR FURNITURE PROVIDED & INSTALLED BY OWNER.
10. ACCENT FLOORING TO CREATE AREA OF DEMARCATION.
11. REINSTALL EXISTING LOUVERS UPON COMPLETION OF
MECHANICAL EQUIPMENT INSTALLATION.
12. NEW VCT FLOORING TO TIE INTO EXISTING.
13. NEW EPOXY COATING ON CONCRETE PAD
HAZARDOUS
COMPOUNDING
N1004C
ANTE ROOM
N1004A
Line of Demarcation
VESTIBULE
N1004
VESTIBULE
N1006B
CORRIDOR
99 SF
STORAGE
N1006A
166 SF
HAZARDOUS
DRUG STORAGE
N1004B
61 SF
WORK AREA
N1002B
ELEVATOR
LOBBY
WAITING
N1013
WOMENS
RESTROOM
N1011
MENS
RESTROOM
N1009
WOMENS STAFF
LOCKERS
N1007
MENS STAFF
LOCKERS
N1005
ELECTRIC
N1003
TEL.
N1001
1,656 SF
PHYSICAL
THERAPY ROOM
N1006
CORRIDOR
985 SF
CHEMOTHERAPY
N1002
N1004XN1004AX
N1004BX
N1004CX
N1
6X
N1
6A X 2
C N1002X
2 2
MIN. CLEAR
4'-0"
M
IN
. C
LE
AR
4' -0
CONFERENCE
D1006
BREAK ROOM
D1006
CHEMOTHERAPY
D1011
CORRIDOR
OFFICE
N1006C
STORAGE
N1008A
TELECOMM
ROOM
R
R
A1.4
A1.4
R3 R3
R1
A1 .6R
R
R1
A0 .4
A0.4 A0.4
A0.4
A1.4
8 3/4"
1'-8"
4' -6
8'-11"
2' -1
/4
3'
-0
3' -0
11'-5 1/8"
9'-8"
2'-11 3/4"
1' -2
/4
'-8
/2
7'-6"
19'-10 1/8"
A121B E6
R
R4R4
EXTEND GWB & STUDS
OVER SILL TO MEET
EXISTING GLAZING.
NEOPRENE GASKET
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C‐2848 AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
PLAN NORTH TRUE NORTH A121B
MJCSEC
FLOOR PLAN - LEVEL 01 - N1004
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020 June 30, 2020
FLOOR PLAN GENERAL NOTES
FLOOR PLAN KEYED NOTES
1/4" = 1'-0"F1 FLR - LEVEL 01 - NEW N1004
3/4" = 1'-0"E6 DETAIL @ PT STORAGE
1 Addendum 1 11/12/2020
| A121A |
| Sheets |
| A051 - PHASING PLAN - LEVEL 01 |
| A101A - DEMOLITION PLAN - LEVEL 01 - F1204 |
| A102 - DEMOLITION PLAN - LEVEL 02 INTERSTITIAL SPACE |
| A121A - FLOOR PLAN - LEVEL 01 - F1204 |
| A121B - FLOOR PLAN - LEVEL 01 - N1004 |
| A122 - FLOOR PLAN - LEVEL 02 - INTERSTITIAL MECHANICAL SPACE |
| A500 - EXTERIOR ELEVATIONS |
| A600 - FINISH INFORMATION |
| A121B |
| Sheets |
| A121B - FLOOR PLAN - LEVEL 01 - N1004 |
| A122 - FLOOR PLAN - LEVEL 02 - INTERSTITIAL MECHANICAL SPACE |
| A500 - EXTERIOR ELEVATIONS |
| A600 - FINISH INFORMATION |
File details come from the government source that posted it. Updated .