Z2DZ--Renovate And Replace Pharmacy AHUs Federal contract opportunity
Solicitation number
36C24620R0152
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

This document includes a demolition plan and general notes for renovations to an existing pharmacy at a Veterans Affairs medical center, as well as the corresponding federal contract opportunity solicitation. The demolition plan outlines selective demolition requirements to prepare the interstitial mechanical space on level two for new construction, including removal of existing walls, doors, plumbing fixtures, equipment, flooring, windows, millwork, shelving, and ductwork. The general notes specify life safety protections, barrier installations, and coordination requirements. The related solicitation seeks proposals to renovate and replace the pharmacy's air handling units, with drawings, specifications, and narratives to be published separately, and the final RFP to follow the pre-solicitation notice. Proposals are due based on the future publication dates.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DZ--Renovate And Replace Pharmacy AHUs, newest first.
File Type Posted
36C24620R0152 0002.docx DOCX document
RFI 11-13 -A121A -A121B.pdf PDF
RFI 05 A122.pdf PDF
RFI 10 A101A and A600.pdf PDF
Interstitial 2nd Floor.pdf PDF
RFI 001 Response Review VA Comments.pdf PDF
RFI 22 A051.pdf PDF
RFI 15 M-701.pdf PDF
36C24620R0152 0001.docx DOCX document
RFI 25 Attachment 2.pdf PDF
RFI 19 -20 MH Sheets.pdf PDF
RFI 16 -17 - 18- M-001.pdf PDF
RFI 12 A600.pdf PDF
Past Performance Questionnaire.pdf PDF
36C24620R0152_3.docx DOCX document
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D-15

GYP. FLOORING 25PSI CONCRETE

STRUCTURAL

FLOOR

D-16

E6 A102

D-15

1. SEE SPECIFICATIONS FOR ADDITIONAL SELECTIVE DEMOLITION

REQUIREMENTS.

2. SEE ENGINEERING DEMOLITION PLANS FOR ADDITIONAL

INFORMATION.

3. EXISTING ADJACENT ROOMS, ABOVE AND BELOW WILL REMAIN

OCCUPIED DURING CONSTRUCTION. NO DISRUPTION OF BUILDING

SYSTEMS OR OPERATIONS ARE PERMITTED WITHOUT PRIOR

APPROVAL BY COR.

4. REFER TO NEW CONSTRUCTION PLANS TO COORDINATE THE

EXTENT OF DEMOLITION WITH NEW CONSTRUCTION.

5. DEMOLITION OF BUILDING SYSTEMS INCLUDING CONDUIT, WIRING,

DUCTWORK AND PLUMBING LINES MAY EXTEND BEYOND THE LIMITS

SHOWN ON THE DEMOLITION PLANS. THIS WORK SHALL BE INCLUDED

IN THE CONTRACTORS SCOPE OF WORK.

6. THE GENERAL CONTRACTOR SHALL SEAL OR PROVIDE FILTERS ON

ALL REMAINING DUCTWORK TO PREVENT INFILTRATION OF DUST.

MAINTAIN FILTERS AS REQUIRED.

7. GENERAL CONTRACTOR SHALL MAINTAIN EGRESS AND INTEGRITY

OF LIFE SAFETY SYSTEMS DURING ALL DEMOLITION AND NEW

CONSTRUCTION.

1. REMOVE EXISTING WALL IN ITS ENTIRETY.

2. REMOVE EXISTING DOOR AND FRAME.

3. REMOVE EXISTING PLUMBING FIXTURE.

4. REMOVE EXISTING MODULAR FURNITURE OR PARTITION.

5. REMOVE EXISTING COMPOUNDING EQUIP. IN ITS ENTIRETY.

6.REMOVE EXISTING WALL AS RQD. FOR NEW DOOR.

7. REMOVE EXISTING EQUIP TO BE RELOCATED. SEE NEW PLAN FOR

LOCATION.

8. REMOVE FLOORING BACK TO CONCRETE SUBFLOOR.

9. REMOVE EXISTING WINDOW & ALL ASSOCIATED FLASHING. PROTECT

STRUCTURE & BUILDIGN INTERIOR DURING DURATION OF REMOVAL &

INFILL.

10. REMOVE EXISTING MILLWORK IN ITS ENTIRETY.

11. REMOVE EXISTING SHELVING AS RQD FOR NEW CONSTRUCTION

12. REMOVE EXISTING DOOR & FRAME TO BE REINSTALLED.

SEE NEW PLAN FOR LOCATION.

13. REMOVE EXISTING SINK UNIT IN ITS ENTIRETY TO BE REINSTALLED.

SEE NEW PLAN FOR LOCATION.

14. REMOVE EXISTING EMERGENCY SHOWER/EYE WASH STATION.

15. REMOVE EXISTING LOUVERS AS RQD. FOR AHU.

16. TEMPORARILY REMOVE EXISTING HVAC DUCT WORK.

17.CONTRACTOR SHALL INSTALL A CLASS 4 ICRA COMPLIANT

BARRIER AND MEASURES AT ALL TIMES. CONTRACTOR SHALL

INSTALL TEMPORARY PLASTIC BARRIER DURING SELECTIVE DEMO

AS NECESSARY TO CONSTRUCT A FIRE RATE 1 HOUR BARRIER.

COORDINATE WITH COR TO ENSURE THE BARRIER IS A CLASS 4

COMPLIANT SYSTEM.

D-#

LEVEL 01

0"

LEVEL 02 -

INTERSTITIAL

MECHANICAL

SPACE

12'-8"

LEVEL 03

25'-4"

ROOF

34'-0"

ETR

D-15 D-15

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management

102 THIRD AVENUE NORTHEAST

HICKORY, NORTH CAROLINA 28601

PHONE: 828.315.9962

NC ENGINEERING LICENSE NO: P-0214

NC ARCHITECTURE LICENSE NO: 51254

o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

CHARLOTTE | 704.295.4263

705 EAST MOREHEAD STREET, 28202

NC License No: C‐2848 AME Project No: 18104

VA FORM 08-6231

F

E

D

C

B

A

PLAN NORTH TRUE NORTH A102

DesignerChecker

DEMOLITION PLAN - LEVEL 02 INTERSTITIAL

SPACE

FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY

June 30, 2020 June 30, 2020

1/4" = 1'-0"F1 FLR - LEVEL 02 -DEMO INTERSTITIAL SPACE

DEMOLITION GENERAL NOTES

DEMOLITION PLAN KEYED NOTES

1/8" = 1'-0"E6 F1204 EXTERIOR ELEVATION - DEMO

1 Addendum 1 11/12/2020

Sheets
A051 - PHASING PLAN - LEVEL 01
A101A - DEMOLITION PLAN - LEVEL 01 - F1204
A102 - DEMOLITION PLAN - LEVEL 02 INTERSTITIAL SPACE
A121A - FLOOR PLAN - LEVEL 01 - F1204
A121B - FLOOR PLAN - LEVEL 01 - N1004
A122 - FLOOR PLAN - LEVEL 02 - INTERSTITIAL MECHANICAL SPACE
A500 - EXTERIOR ELEVATIONS
A600 - FINISH INFORMATION