Perry Point Lead Survey Summary Report_Medgas - Copy.pdf
PDF 172 KB Posted
- Attached to
- Y1DA--VISN 5 - MULTIPLE AWARD TASK ORDER CONTRACT CONSTRUCTION 2022 Federal contract opportunity
- Solicitation number
- 36C24522R0056
About this file
This is a solicitation for a multiple award task order contract for construction services. The contract will be awarded to multiple vendors to provide general construction services including maintenance, repair, alteration, mechanical, electrical, and other construction categories on an as-needed basis. Task orders will vary in size and scope but may include work such as site preparation, roofing, drywall, plumbing, and renovations. Services are needed at Veterans Affairs medical centers in Veterans Integrated Service Network 5. The base period of performance is one year from date of award. Task orders will be fixed price and the contractor's overhead and profit rates will remain fixed for the life of the contract. Davis Bacon wage rates will apply to task orders as relevant. Fair opportunity to compete will be provided for each task order unless an exception applies such as urgency or logical follow-on to a previous order.
View the file
Other files for this federal contract opportunity
Show all 45
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
United States Department of Veterans Affairs
Perry Point Campus
Lead Paint Screening
Environmental Consultants
1331 Ashton Road P.O. Box 646 Hanover, MD 21076 410-684-3327 FAX: 410-684-3384 www.amaconsulting.com
November 13, 2013
Mr. Robert Deinert Safety/Occupational Health Program Manager VA Maryland Healthcare System Perry Point VA Medical Center Bldg. 101, Room 31 Perryville, MD 21902
RE: United States Department of Veteran Affairs VISN 5 Contract No. GS-10F-
0386K Lead Paint Screening for the Veterans Affairs Perry Point Campus
Bldg: Perry Point Campus
AMA Project #: 13404
Mr. Deinert:
Between September 30 and October 31st, 2013 Aerosol Monitoring & Analysis, Inc. (AMA) representatives, Mr. Andrew Washington, Mr. Patrick Dincher, Mr.
Adam Truax, Mr. Rob Schoennagel, Mr. Kinte Thompson, and Mr. Ron Stallard conducted an onsite lead paint screening of the Perry Point VAMC campus facilities for the purpose of identifying lead containing materials within the buildings.
Background Information
Perry Point Campus Perry Point, MD 21902
1,103,000 square feet for inspection
Total Buildings: 50 (including connecting corridors)
Original Construction Dates: Various dates ranging from 1918 – Present (Mansion constructed in 1750)
Renovations Dates: Various dates on select buildings ranging from 1968 - Present
Existing Lead Documentation – None to be relied upon
Buildings inspected by AMA:
(24H) Mental Health (1H) Domiciliary (25H) Mental Health (2H) Domiciliary (26) Fire House (3H) Administration (27H) Biomedical Shop
(4) Research (41) Greenhouse
(4H) IRMS (59)
(5H) Director’s Office (80H) Mental Health Clinic
(5) Stock Storage (82) Education/Research (6H) Voluntary Service (97) Gatehouse
(8) Engineering Storage (101) Administration (9H) Nursing Home (102) Filter Plant
(11) Warehouse (314A) Theater (11H) Human Resources (314B) Recreation (13H) Psychiatric Units (314C) Chapel
(13) Public Health Service (315) Boiler Plant (14H) Psychiatric Units (321) Chiller Plant
(14) (360)
(15) Administration (361) (15H) Rehab (364) (17H) Dietetics Connecting Corridors (18H) Maintenance Shops Credit Union (19H) Medical Wards Mansion House (20H) Medical Media/IRMS Grist Mill
(20) Water Pumping Station REMRO
(22) Filter Plant (22H) Substance Abuse/Detox (23H) Geropsych Nursing
General Summary
AMA randomly tested surfaces for lead containing materials (LCM) throughout each above listed building at the Perry Point VAMC Campus.
Lead Inspector(s) – Andrew Washington (Maryland Risk Assessor 10057) Adam Truax (Maryland Lead Inspector 14117) Robert Schoennagel (Maryland Lead Inspector 4179) Kinte Thompson (Maryland Lead Inspector 13795) Patrick Dincher (Maryland Lead Inspector 7164) Ronald Stallard (Maryland Lead Inspector 4357)
The LCM testing was performed with a Radiation Monitoring Device (RMD) LPA-1 model x-ray fluorescence analyzer (XRF), Serial #1954. The XRF contains a small radioactive source (Cobalt 57), which emits radiation when pressed against a surface. If the paint contains lead, the radiation will stimulate the lead atoms to re-emit x-rays, which are sensed by a detector in the unit. The XRF then converts these signals to a final reading in milligrams of lead per square centimeter of surface area tested (mg/cm2). The LPA-1 XRF is capable of achieving a ninety-five percent confidence interval in readings to a depth of 3/8 inch.
The XRF was calibrated in accordance with the manufacturer's instructions. Prior to obtaining readings from suspect surfaces, three calibration readings were taken on a National Institute for Science and Technology (NIST) Calibration Test Block and recorded. The NIST Calibration Block contains a known concentration of lead (1.02 mg/cm2) and the XRF must indicate 1.02 mg/cm2 with a tolerance of + or - 0.3 mg/cm2 for the average of the three readings. If the average of three readings is within the established tolerance, the unit is working properly. Calibration checks were performed prior to and at the end of the investigation.
The LPA-1 XRF features two modes of operation when in use: Quick mode and Standard mode. When the Quick mode is engaged on the LPA-1, the unit seeks the shortest period of time to assure a positive, or a negative measurement with 95% confidence. As stated in the XRF Performance Characteristics Sheet (PCS) developed jointly by the U.S. EPA and the U.S. Department of Housing and Urban Development (HUD); no substrate correction is needed. The Quick mode was used during the course of the investigation.
Many types of components tested were found to contain greater than (>) 0.7 mg/cm2 of surface area tested, which is the amount defined as a lead-containing material according to the COMAR, Title 26, Department of the Environment, Subtitle 16, Lead, Chapter 01. Table I at the end of the report lists components that were found to have lead concentrations of >0.7 mg/cm2 within each building.
Table II lists all XRF readings that were found to be LCM.
There is no requirement to remove LCM prior to demolition activities for this type of building in the State of Maryland, only that components finished with LCM be tested, to determine the disposal requirements, following the requirements of the Resource Conservation and Recovery Act (RCRA) and any other applicable federal, state and local laws and regulations. In addition, contractors need to be made aware of the existence of LCM so their workers and the environment can be adequately protected. All lead-containing waste is to be handled and disposed of as hazardous waste unless toxic characteristic leaching procedure (TCLP) testing is performed and indicates otherwise. The waste shall be considered as hazardous when the concentration of lead exceeds 5 parts per million (ppm) by the TCLP.
The Occupational Safety and Health Administration (OSHA) Lead in Construction Standard (29 CFR 1926.62, with Maryland Amendments) must be adhered to during demolition to the LCM finished surfaces. This standard established the permissible exposure level (PEL) for lead at 50 micrograms per cubic meter (ug/m3) as an eight-hour time weighted average (TWA); the action level has been established at 30 ug/m3 as an eight hour TWA. This regulation also requires employers to use engineering controls and special work practices to reduce worker lead exposure to, at, or below the PEL. It also triggers several requirements regarding exposure monitoring, biological monitoring, and employee training when a worker is exposed to airborne lead levels at or above the action level.
Some painted surfaces may contain levels of lead at or below 0.7 mg/cm2, which are able to create lead dust or lead-contaminated soil hazards if the paint is turned into dust by abrasion, scraping, or sanding. Whenever renovation or demolition is performed on any painted components, an attempt should be made to control dust. If any surfaces with measurable amounts of lead are to be disturbed, it must be done so in accordance with the OSHA, and by trained personnel using appropriate techniques and respiratory protection. The OSHA does not honor threshold levels of lead in paint.
Below is the facility-wide damaged LCM assessment. Materials that were identified as having peeling, flaking, or chipping lead containing paint are listed. Some of the paint is deteriorated over large areas and these materials are listed as significantly damaged.
Facility Condition Summary for Lead Containing Material
(1H) Domiciliary
Significantly damaged lead paint in building includes: Plaster Ceilings
(2H) Domiciliary
Significantly damaged lead paint in building includes: Plaster Ceilings Isolated damaged lead paint in building includes: Plaster Walls
(3H) Administration
Significantly damaged lead paint in building includes: Plaster Ceilings, Wood Overhangs Isolated damaged lead paint in building includes: Plaster Walls, Metal Grates, Wood Door Jambs, & Wood Door Casings
(4) Research
No damaged lead paint identified
(4H) IRMS
Significantly damaged lead paint in building includes: Plaster Ceilings Isolated damaged lead paint in building includes: Metal Radiator Pipe, & Metal Fire Alarm Case
(5H) Director’s Office
Isolated damaged lead paint in building includes: Plaster Ceilings
(5) Stock Storage
Isolated damaged lead paint in building includes: Metal Stairwell, Concrete Floor, & Brick Window Sills
(6H) Voluntary Service
No damaged paint identified
(8) Engineering Storage
Isolated damaged lead paint in building includes: Metal Door Casings, Wood Door Casings, Metal Steps, & Metal Window Sash
(9H)
Significantly damaged lead paint in building includes: Concrete Walls Isolated damaged lead paint in building includes: Wood Door Frame, Metal Door Casings, Metal Pipe, Metal Window Sash, & Plaster Columns
(11) Warehouse
Significantly damaged lead paint in building includes: Metal Window Sash Isolated damaged lead paint in building includes: Brick Walls, Metal Door Casings, Metal I-beam, Metal Pipe, & Metal Cage
(11H) Human Resources
Isolated damaged lead paint in building includes: Plaster Ceilings
(13) Public Health Service
Isolated damaged lead paint in building includes: Terracotta Brick Ceilings
(13H) Psychiatric Units
Isolated damaged lead paint in building includes: Plaster Columns, Walls & Ceilings, Metal Sinks, Metal Door Casings, Ceramic Baseboard, Concrete Ceilings, Wood Door Train, Metal Hand rail, Concrete Door Trim Base, & Wood Door Trim Base
(14)
Isolated damaged lead paint in building includes: Terracotta Floors, & Metal Window Sash.
(14H) Psychiatric Units
Significantly damaged lead paint in building includes: Plaster Ceilings & Walls Isolated damaged lead paint in building includes: Metal Hand rail, Wood Window Casings, & Metal Grate
(15) Administration
Isolated damaged lead paint in building includes: Wood Window Sash, Metal Window Sash, Steel I-beam, Metal Structural Beam, Wood Door, Wood Door Frame, & Wood Window Frame
(15H) Rehab
No damaged paint identified
(17H) Dietetics
Isolated damaged lead paint in building includes: Metal Step, Metal Riser, Metal Hand rail, Concrete Ceiling, Metal Newel Post, & Metal Safety Rail
(18H) Maintenance Shops
Isolated damaged lead paint in building includes: Plaster Walls, Metal Fire Extinguisher Case, Metal Fan Casing, Metal Fire Protection Pipe, & Porcelain Sink
(19H) Medical Wards
No damaged paint identified
(20H) Medical Media/IRMS
No damaged paint identified
(20) Water Pumping Station
Isolated damaged lead paint in building includes: Wood Door Casings, & Concrete Base
(22) Filter Plant
Isolated damaged lead paint in building includes: Wood Column, Wood Stairs, & Wood Walls.
(22H) Substance Abuse/Detox
Isolated damaged lead paint in building includes: Porcelain Toilet, Porcelain Sink, Concrete Floor, & Metal Pipe
(23H) Geropsych Nursing
No damaged paint identified
(24H) Mental Health
Isolated damaged lead paint in building includes: Metal Hand rail
(25H) Mental Health
No damaged paint identified
(26) Fire House
(27H) Biomedical Shop
No damaged paint identified
(41) Greenhouse
Isolated damaged lead paint in building includes: Terracotta Walls, & Wood Soffit
(59)
No damaged paint identified.
(80H) Mental Health Clinic
Isolated damaged lead paint in building includes: Concrete Walls, CMU Wall, Wood Door, Wood Door Casings, Concrete Ceiling, Wood Soffit, & Wood Fascia
(82) Education/Research
Significantly damaged lead paint in building includes: Concrete Walls & Ceilings Isolated damaged lead paint in building includes: Wood Hatch Door, Wood Door Casings, Metal Pipe, Metal Door, Metal Door Casings, Wood Window Sash, Wood Window Casings, & Wood Window Sill
(97) Gatehouse
No damaged paint identified.
(101) Administration
Significantly damaged lead paint in building includes: Attic Steel Structure, Wood Structure Isolated damaged lead paint in building includes: Concrete Column, Steel I-beam, Steel Plank, Steel Joist, & Brick Walls
(102) Filter Plant
Isolated damaged lead paint in building includes: Wood Door, Walls, & Door Casings, & Metal Pipe.
(314A) Theater
Isolated damaged lead paint in building includes: Metal Window Lintel
(314B) Recreation
Isolated damaged lead paint in building includes: Metal Baseboard
(314C) Chapel
No damaged paint identified.
(315) Boiler Plant
Isolated damaged lead paint in building includes: Metal Tank
(321) Chiller Plant
Isolated damaged lead paint in building includes: Metal Support Column
(360)
Isolated damaged lead paint in building includes: Metal Corners
(361)
Isolated damaged lead paint in building includes: Metal Hand Rail
(364)
No damaged paint identified
Connecting Corridors
No damaged paint identified
Credit Union
No damaged paint identified
Mansion House
Significantly damaged lead paint in building includes: Plaster Walls and Ceilings, Wood Window Sill, Wood Shutter, Wood Door & Walls, Wood Awning, & Wood Window Casings Isolated damaged lead paint in building includes: Wood Stair Carriage, Wood Window Sash, Wood Door Casings, Wood Crown Molding
Grist Mill
Significantly damaged lead paint in building includes: Wood Door, Door Casings, & Window Casings
REMRO
If you have any questions regarding this summary or the attached data spreadsheets, please contact me at our office.
Sincerely, Andrew Washington Project Manager
Attachments
TABLE I – LEAD BASED PAINT COMPONENT TABLE
TABLE I
LBP COMPONENT TABLE
VA PERRY POINT
NOVEMBER 2013
Building 1H
Plaster Walls & Ceilings
Porcelain Sinks Metal Door
Casings Wood Door
Casings Wood Porch
Ceiling Wood Roof
Truss Concrete
Ledge Building 2H
Plaster Walls & Ceilings
Metal Stairtread Wood Door
Casings Wood Porch
Ceiling Concrete Ledge
Wood Roof Truss
Building 3H
Wood soffit Metal Grate Wood Door
Casings Metal Hand rail Plaster Walls &
Ceilings Metal
Baseboard Metal Door
Lintel Metal Sink Wood Door Jamb
Building 4
Concrete Stair Metal I-beam Cinderblock Wall Metal Pipe Metal Door
Casings Metal
Radiator Porcelain Sink
Concrete Soffit Wood Soffit Metal Hand Rail
Building 4H
Plaster Walls, Ceilings, & Columns
Ceramic Wall Tile Metal Radiator
Pipe Metal Stair
Tread Wood Roof Truss Metal Pipe
Wood Door Casing
Metal Fire Alarm Case
Metal Hand Rail
Building 5
Metal Window Sash Metal Hand Rail Wood Window
Casing Metal
Stairwell Metal I-beam Metal Door Concrete Floor
Metal Support Beam Concrete Support
Beam Concrete Walls
Brick Wash Sink
Brick Walls Metal Pipe Metal
Structural Support Strip
Brick Window Sill Metal Shelf
Building 5H
Plaster Walls, Ceilings, & Columns
Porcelain Sinks Metal Pipe Metal
Stairtread Metal Kick Plate
Ceramic tile Baseboard
Plaster Door Casing
Building 6H
Porcelain Sink Metal Hand rail
Building 8
Metal Door Casing Wood Door Casing Brick Walls Concrete
Walls Metal Wall Bin
Flange Wood Door Metal Step
Metal Window Sash Dryvit Window Sill
Building 9H
Wood Door Frame Wood Column Metal Hand Rail Concrete
Walls Plaster Walls
Plaster Door Jamb
Plaster Columns
Metal Locker Porcelain Sinks Plaster Walls and Ceilings
Metal Door Casing
Metal Shelf Porcelain Tub Metal Pipe
Metal Window Sash Metal Cage Door Wood Door
Building 11
Brick Walls Metal Door Casing Metal I-beam Metal
Window Sash Wood Door
Casing Metal Pipe
Wood Window Sash
TBL I-1
VA PERRY POINT
NOVEMBER 2013
Metal Cage Metal I-beam crossbar Concrete Walls
Metal Horizantal Support Beam
Concrete Window Casing
Concrete Floor
Metal Ladder
Metal Shelf Metal Cabinet
Building 11H Plaster Walls &
Ceilings Metal Extinguisher
Case Metal Door
Casings Metal Hand
Rail Porcelain Sinks Metal Pipe
Porcelain Slop Sink
Metal Fire Box Metal Window Sash
Building 13 Terracotta Brick
Ceiling Concrete Ceiling
Deck Concrete Walls Metal Pipe
Building 13H
Plaster Walls, Ceilings, & Columns
Metal Door Casing Metal Sink Ceramic
Baseboard Ceramic Wall Tile Metal Stringer Metal Riser
Metal Radiator Metal Ballard Wood Door
Frame Metal Hand rail Concrete Door
Trim Base Metal Down Spout Drain
Porcelain Sinks
Concrete Ceiling Wood Door Trim
Base
Building 14
Metall Support Pole Metal I-beam Metal Door
Casings Concrete Ceiling
Metal Cage Terracotta
Floor Concrete Walls
Wood Door Metal Stair Railing Metal Window
Sash Cinder Block
Walls Metal Window Sill
Concrete Base
Metal Safety Rail
Concrete Window Sill
Building 14H Plaster Walls &
Ceilings Metal Door Casing
Metal Newel Post
Metal Hand Rail
Metal Stringer Metal Riser Wood Door
Casing Wood Window
Casing Metal Grate
Building 15 Plaster Walls &
Ceilings Brick Walls
Wood Window Frames
Wood Window Sill
Wood Window Sash
Porcelain Sinks
Metal Window Sash
CMU Walls Metal Support Pole Metal Hand Rail Steel I-beam Metal Support
Strip Metal Pipe Metal Wall
Metal Conduit Pipe Metal Structural
Beam Wood Door
Wood Door Frame
Building 15H
Metal Door Casing Plaster Walls &
Ceiling Wood Door
Transom Porcelain
Sinks Porcelain Urinals
Ceramic Walls
Metal Pipe
Metal Hand rail Concrete Cellar Door
Case Metal Cellar Door Cage
Concrete Window Sill
Metal Ballard
Building 17H
Metal Door Casing Concrete Walls Metal Step Metal Kick
Plate Metal Riser
Metal Hand Rail
Concrete Ceiling
Metal Rail Metal Newel Post Metal Safety Rail
Building 18H
TBL I-2
VA PERRY POINT
NOVEMBER 2013
Metal Fire Extinguisher Case
Metal Fan Casing Metal Fire
Protection Pipe Metal Door
Casing Ceramic tile
Walls Concrete
Walls Plaster Walls &
Ceilings
Wood Column Metal Window Porcelain Sinks Metal Rail Metal Down
Spout Fan Case
Building 19H
Plaster Walls & Ceilings
Metal Radiator Cover Concrete Walls Metal
Electical Box Door
Metal Radiator Metal Cage Metal Stair
Riser
Metal Spindle Metal Newel Post Metal Kick Plate Concrete Ceiling
Metal Door Casings
Wood Crawlspace
Case Metal Pipe
G tilo Wall Concrete Columns
Building 20
Metal Lintel Wood Door Casing Metal Door
Frame Concrete
Base Building 20H
Cinderblock Walls Cinderblock Window
Sill Metal Window
Mullion Metal Pipe
Building 22
Wood Column Metal I-beam Wood Stairs Wood Walls
Building 22H
Metal Radiator Cover Plaster Walls Porcelain Sinks Porcelain
Toilet Ceramic tile Baseboard
Metal Door Casing
Metal Trap Door
Wood Window Casing
Plaster Radiator Cover
Metal Hand rail Metal Riser Metal Newel Post Ceramic tile
Wall Plaster
Window Case
Metal I-beam Concrete Floor Metal Pipe Wood Mullion Metal Stringer Metal Step Wood Door
Casing
Plaster Door Trim Concrete Door Stoop Metal Rail Metal Fire
Box Building 23H
Metal Vent Cover Metal Hand Rail Metal Stair
Stringer Metal Stair
Riser Metal Stairtread
Metal Newel Post
Plaster Walls
Building 24H
Metal Hand rail Wood Door Frame Wood Window
Sill Metal Door
Casing Ceramic Wall
Wood Window Casing
Building 25H
Metal Baseboard Metal Window Case Metal Stringer Metal Kick
Plate Wood Window
Casing
Metal Radiator Cover
Wood Window Sill
Metal Window Jamb Metal Window Sill Wood Door
Casings Metal Fire
Box Metal Pipe
Building 26
Metal Conduit Wood Window Wood Door
Casings Metal
Window Sill Building 27H
Ceiling
Building 41
Plaster Walls & Ceilings
Wood Window Sill Wood Window
Casing Wood
Window Sash Wood Door
Wood Door Casing
Metal Pipe
TBL I-3
VA PERRY POINT
NOVEMBER 2013
Drywall Walls Terracotta Wall Wood Soffit
Building 59
No LBP
Building 80H
Concrete Walls Plaster Walls, Columns, & Ceilings Wood Crown
Molding Wood
Window Sill Wood Window
Casing Metal
Radiator Metal Door
Casing
Wood Shelf Ceramic Glazed Tile Wood Door
Casings Plaster Door
Casing Metal Newel Post
Metal Sprinkler
CMU Wall
Concrete Ceiling Wood Door Wood Window Concrete Column
Wood Column Wood Soffit Wood Fascia
Building 82
Plaster Walls, Ceilings, & Columns
Wood Crown Molding Wood Window
Casing Wood
Window Sill Wood Fireplace
Mantle Wood Door
Wood Door Casing
Metal Door Casing Metal Door Jamb Plaster Door
Casing Porcelain
Sinks Metal Ladder
Metal Roof Hatch
Wood Shelf
Metal Radiator Concrete Walls Concrete Ceiling Wood Hatch
Door Metal Pipe Metal Door Wood Column
Wood Fascia Wood Soffit Wood Decorative
Trim Wood
Window Sash
Building 97
Wood Window Sash Plaster Walls &
Ceiling Wood Door
Wood Door Casings
Wood Window Sill
Wood Window Casing
Wood AC Casing
Wood Soffit Wood Fascial Board
Building 101
Stucco Walls Concrete Columns Metal Door
Casings Metal Bottom
Trim Steel Structure
Wood Structure
Steel I-beam
Steel Plank Steel Joist Brick Walls Concrete
Down Spout Building 102
Wood Door Wood Door Casing Wood Wall Metal Pipe
Building 314A
Metal I-beam Metal Door Lintel Ceramic Wall Metal Hand rail Metal Newel Post
Metal Stair Stringer
Metal Kick Plate Riser
Metal Stairtread Metal Window Lintel Metal Base Plate
Building 314B
Metal Baseboard Metal Hand rail Wood Alley Floor
Strip Metal Newel
Post Metal Stair
Stringer Metal Stair
Riser Metal Stair Carriage
Metal I-beam
Building 314C
Metal Window Lintel
Building 315
Metal Wall Metal I-beam Metal Pipe Metal Boiler Metal Tank Metal Trench
Cover Metal Door
TBL I-4
VA PERRY POINT
NOVEMBER 2013
Building 321
Metal Door Casing Metal I-beam Metal Pipe Metal Tension
Rods Metal Support
Column
Building 360
Ceramic tile Metal Stall Metal Corner Metal Ladder Metal Pipe Metal Loading
Plate
Building 361
Ceramic tile Wall Metal Hand rail
Building 364
No LBP Connecting Corridors
Metal Ballard Metal Corner
Protector Metal Door
Metal Door Casing
Metal Door Lintel Metal Window
Lintel
Credit Union
No LBP
Mansion House
Plaster Walls & Ceilings
Wood Crown Molding Wood
Baseboard Wood Door
Wood Window Panel
Wood Fire Mantle
Wood Fireplace Case
Wood Window Sill Wood Window
Casing Wood Window
Well Wood Door
Casings Wood Shelf
Wood Window Sash
Wood Stair Carriage
Ceramic tile Wall Wood Shutter Concrete Walls Wood Walls Wood Awning
Grist Mill
Wood Door Wood Door Casing Wood Window
Casing
REMRO
Porcelain Sink
TBL I-5
TABLE II – POSTIVE XRF TABLE
TABLE II
POSITIVE XRF TABLE
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
Building 1H
005 1H foyer Tan Wall Plaster Intact >9.9
035 SP 128 Conference room Tan Ceiling Plaster Not intact >9.9 041 SP 130 Tan Ceiling Plaster Not intact >9.9 047 Exam room Tan Ceiling Plaster Not intact >9.9 049 West stairwell Tan Wall Plaster Intact >9.9 050 West stairwell Tan Wall Plaster Intact >9.9 051 West stairwell Tan Wall Plaster Intact >9.9 052 West stairwell Tan Wall Plaster Intact >9.9 055 West stairwell Tan Ceiling Plaster Intact >9.9 062 SP 225 Bedroom Tan Wall Plaster Intact >9.9 090 SP 211 White Sink Porcelain Intact >9.9 091 SP 211 Brown Door casing Metal Intact 0.8 095 SP 206 Tan Wall Plaster Intact >9.9 097 SP 206 Tan Wall Plaster Intact >9.9 099 SP 206 Off-white Ceiling Plaster Not intact >9.9 112 Exterior Tan Door casing Wood Intact 2.9 114 Exterior Tan Porch ceiling Wood Intact 3.6 123 Exterior Tan Roof truss Wood Intact >9.9 124 Exterior Red Ledge Concrete Intact 0.8
Building 2H
005 2H foyer Tan Wall Plaster Intact 7.9 006 2H foyer Tan Wall Plaster Intact 7.3 012 1st floor hallway Tan Wall Plaster Intact 4.5 018 1st floor hallway Off-white Wall Plaster Not intact 9.0 031 South stairwell Blue Stairtread Metal Intact 0.8 044 113 TV lounge Off-white Ceiling Plaster Not intact >9.9 047 102 Electrical closet Tan Wall Plaster Not intact 0.8 049 102 Electrical closet Tan Wall Plaster Intact 1.7 063 S100 Stairway Tan Wall Plaster Intact 1.3 064 S100 Stairway Tan Wall Plaster Intact 9.3 065 S100 Stairway Tan Wall Plaster Intact >9.9 067 S100 Stairway Tan Ceiling Plaster Intact >9.9 075 212 Multi-purpose Off-white Ceiling Plaster Not intact >9.9 088 216 Crach cart room Tan Ceiling Plaster Not intact >9.9 105 118 Residence room Off-white Ceiling Plaster Not intact >9.9 106 Exterior Off-white Door casing White Intact 0.8 108 Exterior Off-white Porch ceiling Wood Intact 2.2 113 Exterior Brown Ledge Concrete Intact 0.8 115 Exterior Tan Roof truss Wood Intact 1.4
Building 3H
007 Exterior White Soffit Wood Not intact 3.9 008 Exterior White Soffit Wood Not intact 3.7 011 Exterior Black Grate Metal Not intact 2.4 012 Exterior Off-white Door casing Wood Intact 3.9 014 Exterior Black Hand rail Metal Intact 0.8 016 1st floor - main entrance White Wall Plaster Intact >9.9 021 1st floor - main entrance White Ceiling Plaster Not intact >9.9
TBL II-1
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
027 1st floor - main entrance Tan Ceiling Plaster Not intact >9.9 034 1st floor - medical library Tan Ceiling Plaster Not intact >9.9 041 1st floor - stairwell S-119 Black Baseboard Metal Intact 0.8 046 1st floor - Room 116 White Wall Plaster Intact >9.9 047 1st floor - Room 116 White Wall Plaster Intact >9.9 051 1st floor - Room 116 Green Ceiling Plaster Not intact >9.9 053 1st floor - stairwell S-102 White Wall Plaster Intact >9.9 054 1st floor - stairwell S-102 White Wall Plaster Intact 4.9 055 1st floor - stairwell S-102 White Wall Plaster Intact >9.9 056 1st floor - stairwell S-102 White Wall Plaster Intact >9.9 057 1st floor - stairwell S-102 White Ceiling Plaster Intact >9.9 058 1st floor - stairwell S-102 Gray Hand rail Metal Intact 0.8 067 1st floor - main corridor White Wall Plaster Intact >9.9 068 1st floor - main corridor White Wall Plaster Intact >9.9 070 1st floor - main corridor White Ceiling Plaster Not intact >9.9 077 1st floor - Room 111 Brown Door lentil Metal Intact 6.3 078 1st floor - Room 111 White Sink Metal Intact >9.9 085 2nd floor - Room 220 White Ceiling Plaster Not intact >9.9 090 2nd floor - Main corridor White Ceiling Plaster Not intact >9.9 093 2nd floor - Room 208 White Ceiling Plaster Not intact >9.9 099 2nd floor - Room 201A White Ceiling Plaster Not intact >9.9 104 2nd floor - Room 201F White Wall Plaster Intact >9.9 105 2nd floor - Room 201F White Ceiling Plaster Intact >9.9 111 2nd floor - Room 201D White Ceiling Plaster Intact 2.4 117 2nd floor - Room 201 Blue Wall Plaster Not intact >9.9 118 2nd floor - Room 201 White Ceiling Plaster Not intact >9.9 119 2nd floor - Room 201 White Door jamb Wood Not intact >9.9 120 2nd floor - Room 201 White Door casing Wood Not intact >9.9 123 2nd floor - Room 203 White Wall Plaster Intact >9.9 129 2nd floor - Room 203 White Ceiling Plaster Not intact >9.9
Building 4
009 Lobby Off-white Stair Concrete Intact 0.8 013 Lobby Off-white I-beam Metal Intact 2.8 018 Print shop Tan Wall Cinder block Intact 5.1 020 Print shop Tan Pipe Metal Intact 3.9 021 Print shop Tan Door casing Metal Intact 5.9 036 Main Corridor Off-white Door casing Metal Intact 3.2 063 Stairwell (west) Off-white Radiator Metal Intact 0.8 068 2nd floor foyer Off-white I-beam Metal Intact 0.8 070 2nd floor foyer Off-white Door casing Metal Intact 5.2 076 211 floor foyer White Sink Pocelain Intact 3.3 110 Exterior roof Off-white Soffit Concrete Intact 0.8 114 Exterior Off-white Soffit Wood Intact >9.9 121 Exterior Gray Hand rail Metal Intact 0.8
Building 4H
005 Lobby Off-white Wall Plaster Intact >9.9 007 Lobby Off-white Wall Plaster Intact 0.8 012 Hallway 1st floor Off-white Wall Plaster Intact >9.9 018 Hallway 1st floor Off-white Wall Ceramic tile Intact 3.5 021 Stairwell Off-white Wall Plaster Intact >9.9
TBL II-2
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
022 Stairwell Off-white Wall Plaster Intact >9.9 023 Stairwell Off-white Wall Plaster Intact >9.9 024 Stairwell Off-white Wall Plaster Intact >9.9 025 Stairwell Off-white Wall Plaster Intact >9.9 033 Supply closet Off-white Wall Plaster Intact >9.9 035 103 FCP Services Off-white Wall Plaster Intact >9.9 048 Room 103B Off-white Column Plaster Intact >9.9 049 Room 103B Tan Ceiling Plaster Not intact >9.9 056 Men's room Gray Wall Plaster Intact >9.9 065 Men's room Gray Radiator pipe Metal Not intact 0.8 083 2nd floor hall Off-white Wall Plaster Intact >9.9 085 2nd floor hall Off-white Wall Plaster Intact >9.9 090 2nd floor hall Tan Ceiling Plaster Not intact >9.9 094 202-205 Corridor Off-white Wall Plaster Intact >9.9 100 Kitchen/conference room Off-white Wall Plaster Intact >9.9 101 Kitchen/conference room Off-white Wall Plaster Intact >9.9 106 Mechanical room Red Stair tread Metal Intact 0.8 111 Exterior Tan Roof truss Wood Intact 1.3 114 Exterior Tan Pipe Metal Intact 0.8 115 Exterior Tan Door casing Wood Intact 1.6
118 Exterior Red Fire alarm case Metal Not intact 6.1 122 Exterior Black Hand rail Metal Intact 0.8 125 Exterior Tan Roof truss Wood Intact 2.0
Building 5
008 Exterior, west wall Tan Window sash Metal Intact 0.8 011 Exterior, north wall Yellow Handrail Metal Intact 0.8
022 Exterior, east wall Off-white Window casing Wood Intact 0.8 024 Exterior, south wall Black Stairwell Metal Not intact 5.4 036 Interior, electric room White I-beam Metal Intact 0.8
Interior, ground floor warehouse Red Door Metal Intact 1.4 070 Interior, Paint storage Gray Floor Concrete Not intact 0.8
076 Interior, warehouse storage Yellow Support Beam Metal Intact 0.8
077 Interior, warehouse storage Red Support Beam Concrete Intact 0.8
079 Interior, warehouse storage White I-beam Metal Intact 0.8
085 Interior, warehouse storage White Wall Concrete Intact 0.8
Interior, Refrigerator #3 room White Wash sink Brick Intact 0.8
Interior, Refrigerator #3 room White Wall Brick Intact 0.8
110 Interior, warehouse (east) White Wash sink Brick Intact 0.8
Warehouse interior, 2nd level White Wall Brick Intact 0.8
TBL II-3
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
Warehouse interior, 2nd level White Pipe Metal Intact 0.8
Warehouse interior, 2nd level White Structural
Support Strip Metal Intact 0.8
Warehouse interior, 2nd level White Window sash Metal Intact >9.9
Warehouse interior, 2nd level White Window sill Brick Not intact 0.8
Warehouse interior, 2nd level Gray Window sash Metal Intact 2.3
Warehouse interior, 2nd level Gray Window sill Brick Not intact 0.8
Warehouse interior, 2nd level Orange Shelf Metal Intact 0.8 Building 5H
005 Lobby Off-white Wall Plaster Intact >9.9 006 Lobby Off-white Wall Plaster Intact 9.1 012 1st floor corridor Off-white Wall Plaster Intact 8.8 013 1st floor corridor Off-white Wall Plaster Intact 9.6 014 1st floor corridor Off-white Wall Plaster Intact >9.9 015 1st floor corridor Off-white Wall Plaster Intact 6.3 021 1st floor corridor Off-white Ceiling Plaster Not intact >9.9 029 1st floor corridor White Sink Porcelain Intact >9.9 038 Room 103 Green Ceiling Plaster Not intact >9.9 043 Copy room 109 Off-white Wall Plaster Intact >9.9 046 Copy room 109 Off-white Sink Porcelain Intact 2.6 056 South stairwell Red Pipe Metal Intact 0.8 057 South stairwell Black Stair tread Metal Intact 0.8 059 South stairwell Black Kick plate Metal Intact 0.8 065 206B Off-white Wall Plaster Intact 8.1 066 206B Off-white Wall Plaster Intact 6.1 067 206B Off-white Ceiling Plaster Intact >9.9 081 2nd floor corridor Off-white Wall Plaster Intact >9.9 087 Bathroom (unisex) White Ceiling Plaster Intact >9.9 096 Kitchen Off-white Wall Plaster Intact >9.9
099 Kitchen Brown Baseboard Ceramic tile Intact >9.9 101 Stair #2 Off-white Wall Plaster Intact 8.5 102 Stair #2 Off-white Wall Plaster Intact 8.4 103 Stair #2 Off-white Wall Plaster Intact >9.9 104 Stair #2 Off-white Wall Plaster Intact 6.2 105 Stair #2 Off-white Ceiling Plaster Intact 5.9 109 Executive suit White Wall Plaster Intact >9.9 111 Executive suit White Wall Plaster Intact 8.5 114 Executive suit White Column Plaster Intact 7.3 117 Exterior Tan Door casing Plaster Intact 1.3 126 Exterior Red Pipe Metal Intact 0.8
Building 6H
017 Room 9 Off-white Sink Porcelain Intact >9.9 033 Exterior Black Hand rail Metal Intact 1.9
TBL II-4
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
Building 8
004 Warehouse Brown Door casing Metal Not intact 6.2 014 Warehouse White Door casing Wood Not intact 6.6 018 Ice machine room White Wall Brick Intact 0.8 024 Break room Tan Wall Concrete Intact 1.3
039 Storage Black Wall bin flange Metal Intact 0.8 040 Storage White Door Wood Intact 4.7 041 Platform Gray Step Metal Not intact 0.8 051 Exterior Red Window sash Metal Not intact 1.9 052 Exterior Tan Window sill Dryvit Intact 0.8 053 Exterior Red Door casing Metal Not intact 3.2 060 Exterior Brown Door casing Metal Not intact 3.9
Building 9H
006 Exterior Tan Door frame Wood Not intact >9.9 007 Exterior Tan Column Wood Intact >9.9 008 Exterior Black Hand rail Metal Intact 4.2 013 Exterior Brown Wall Concrete Intact 0.8 015 Exterior Off-white Wall Concrete Intact 0.8 016 Exterior Black Hand rail Metal Intact 4.4 024 1st floor corridor White Wall Plaster Intact >9.9 029 Room 148 White Door jamb Plaster Intact >9.9 030 Room 148 White Door frame Metal Intact >9.9 038 Room 16 White Column Plaster Intact >9.9 039 Room 16 Orange Locker Metal Intact 1.5 042 Laundry room Blue Column Plaster Intact >9.9 044 Laundry room White Sink Porcelain Intact >9.9 074 East stairwell White Wall Plaster Intact >9.9 075 East stairwell White Wall Plaster Intact >9.9 076 East stairwell Tan Hand rail Metal Intact 8.0 087 Room 264 Pink Locker Metal Intact 0.8 091 Room 248 White Door casing Metal Intact >9.9 100 Room 258 White Door casing Metal Intact >9.9 101 Room 258 White Wall Plaster Intact >9.9 110 Room 249 Yellow Shelf Metal Intact 0.8 111 Room 249 White Sink Porcelain Intact >9.9 115 2nd floor lounge White Wall Plaster Intact >9.9 125 Room 209 Orange Locker Metal Intact 1.7 126 Room 209 White Wall Plaster Intact >9.9 129 Room 219 White Wall Plaster Intact >9.9 131 Room 219 White Wall Plaster Intact >9.9 132 Room 219 White Door casing Metal Intact >9.9 140 Room 215 White Tub Porcelain Intact >9.9 150 Basement corridor White Wall Concrete Not intact >9.9 151 Basement corridor White Wall Concrete Not intact >9.9 152 Basement corridor White Wall Concrete Not intact 9.4 153 Basement corridor White Wall Concrete Not intact >9.9 155 Basement corridor White Door casing Metal Not intact 8.0 156 Basement corridor Red Pipe Metal Not intact 0.8 160 Mechanical room White Window sash Metal Not intact >9.9
TBL II-5
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
162 Boiler room Tan Cage door Metal Intact >9.9 163 Boiler room Gray Door casing Metal Intact >9.9 169 Storage room White Sink Porcelain Intact >9.9 170 Storage room Tan Door frame Wood Intact >9.9 171 Storage room Tan Door Wood Intact >9.9 172 Storage room Tan Wall Concrete Intact >9.9 174 Basement bedroom Green Wall Concrete Not intact 9.5 175 Basement bedroom Green Wall Concrete Not intact 7.2 176 Basement bedroom Green Door casing Metal Not intact 9.6 177 Basement bedroom Green Wall Concrete Not intact >9.9 178 Basement bedroom Green Door casing Metal Not intact >9.9 179 Basement bedroom Green Column Plaster Not intact >9.9 190 1st floor - Room 104 Tan Locker Metal Intact 1.4 195 Exterior Black Hand rail Metal Intact 2.6
Building 11
005 Exterior, north wall White Wall Brick Not intact 1.9 006 Exterior, north wall Brown Door casing Metal Not intact 0.8 008 Exterior, north wall White I-beam Metal Intact >9.9 011 Exterior, north wall Brown I-beam Metal Not intact >9.9 013 Exterior, west wall White Window sash Metal Not intact 9.3 016 Exterior, west wall Brown Door casing Metal Intact 0.8 019 Exterior, south wall Brown Door casing Metal Intact 0.8 022 Exterior, south wall White Window sash Metal Not intact 0.8 024 Exterior, south wall White Door casing Wood Intact 3.0 030 Exterior, east wall Red Pipe Metal Not intact 1.5 031 Exterior, north wall White Window sash Wood Not intact 3.1
Interior, warehouse 1st level Green Cage Metal Not intact 1.7
Interior, warehouse 1st level White I-beam Metal Intact 8.6
Interior, warehouse 1st level White I-beam crossbar Metal Intact 0.8
Interior, warehouse 1st level White Wall Brick Intact 0.8
Interior, warehouse 1st level Yellow I-beam Metal Not intact 7.4
Interior, warehouse 1st level Red Wall Brick Intact 0.8
Interior, warehouse 1st level Yellow I-beam Metal Intact >9.9 064 Warehouse 2nd level White I-beam Metal Intact >9.9 065 Warehouse 2nd level Green Wall Brick Not intact 0.8 066 Warehouse 2nd level Gray Window sash Metal Intact >9.9 072 Warehouse 2nd level White Wall Concrete Intact 0.8 076 Warehouse 2nd level Green I-beam Metal Intact 2.5 077 Warehouse 2nd level Green Wall Brick Intact 0.8
080 Warehouse 2nd level Gray Horizantal support beam Metal Intact 0.8 093 Warehouse 3rd level Green I-beam Metal Intact 0.8 099 Warehouse 3rd level Red I-beam Metal Intact >9.9
TBL II-6
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
103 Warehouse 3rd level White Window casing Concrete Intact >9.9
105 Warehouse 3rd level White Window casing Concrete Intact >9.9 107 Warehouse 4th level Gray Floor Concrete Intact >9.9 112 Warehouse 4th level Yellow I-beam Metal Intact 7.8 113 Warehouse 4th level Black Ladder Metal Intact 1.7 114 Warehouse 4th level Black I-beam Metal Intact 2.8 116 Warehouse 4th level Black Pipe Metal Intact 3.9 121 Warehouse 4th level Yellow Shelf Metal Intact 1.6 122 Warehouse 4th level Yellow Shelf Metal Intact 1.5 132 Warehouse 4th level Yellow Shelf Metal Intact 1.7
Warehouse bathroom 1st level Blue Pipe Metal Intact 2.4
Warehouse bathroom 1st level Blue I-beam Metal Intact 8.9
150 Warehouse office 1st level Blue Cabinet Metal Intact 2.2 159 Warehouse 1st level West I-beam Metal Intact 5.5
Building 11H
009 1st floor hall Off-white Wall Plaster Intact 0.8 016 Human resource lobby Off-white Wall Plaster Intact 4.4
018 Human resource lobby Off-white Extinguisher case Metal Intact 4.9 019 Human resource lobby Off-white Door casing Metal Intact >9.9 021 Central stairwell Off-white Wall Plaster Intact 6.5 022 Central stairwell Off-white Wall Plaster Intact 3.5 024 Central stairwell Off-white Wall Plaster Intact 3.7 025 Central stairwell Black Hand rail Metal Intact 0.8 028 Central stairwell Off-white Ceiling Plaster Intact >9.9 031 2nd floor lobby Off-white Wall Plaster Intact 3.0 032 2nd floor lobby Off-white Wall Plaster Intact 5.7 033 2nd floor lobby Off-white Wall Plaster Intact 7.8 034 2nd floor lobby Off-white Door casing Metal Intact >9.9 036 2nd floor lobby Off-white Door casing Metal Intact >9.9 038 2nd floor hallway Off-white Wall Plaster Intact 7.3 039 2nd floor hallway Off-white Wall Plaster Intact 5.7 043 2nd floor hallway Off-white Door casing Metal Intact >9.9 045 2nd floor hallway Off-white Door casing Metal Intact >9.9 048 Copy room 201 Off-white Wall Plaster Intact 8.1 054 Men's room Off-white Wall Plaster Intact >9.9 055 Men's room Off-white Wall Plaster Intact >9.9 057 Men's room Off-white Wall Plaster Intact >9.9 060 Men's room White Sink Porcelain Intact >9.9 063 Men's room White Door casing Metal Intact >9.9 068 Men's room Off-white Ceiling Plaster Not intact >9.9 072 North lobby Off-white Wall Plaster Intact 7.2 074 North lobby Off-white Door casing Metal Intact >9.9
076 North lobby Off-white Extinguisher case Metal Intact 5.6 084 Room 211 Off-white Door casing Metal Intact >9.9
TBL II-7
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
090 House keeping closet Off-white Sink Porcelain Intact >9.9 091 House keeping closet Off-white Door casing Metal Intact 9.0 095 House keeping closet White Pipe Metal Intact 0.8 103 Vending room Off-white Wall Plaster Intact 6.2 107 Vending room Off-white Door casing Metal Intact >9.9 112 Janitor closet Off-white Slop sink Porcelain Intact >9.9 113 Janitor closet Off-white Door casing Metal Intact >9.9 117 Exterior Red Fire box Metal Intact 0.8 125 Exterior White Window sash Metal Intact 0.8
Building 13
029 2nd floor - CIMS Office Gray Ceiling Terracotta brick Not intact >9.9 066 1st floor - corridor White Ceiling deck Concrete Intact >9.9 071 Exterior - south wall Tan Wall Concrete Intact 0.8 075 Exterior - east wall Tan Pipe Metal Intact 0.8
Building 13H
1st floor, main entrance, vestibule Off-white Wall Plaster Intact 6.0
1st floor, main entrance, vestibule Beige Door casing Metal Intact 2.5
1st floor, main entrance, vestibule Beige Door casing Metal Intact 5.2
1st floor, main hall
(east/west) Off-white Wall Plaster Intact 6.1
1st floor, main hall
(east/west) Off-white Wall Plaster Intact 5.3 018 1st floor, Room 125 Off-white Door casing Metal Intact 0.8 025 1st floor, Room 129 Blue Wall Plaster Not intact >9.9 026 1st floor, Room 129 White Sink Metal Not intact 0.8 028 1st floor, Room 129 Blue Wall Plaster Not intact >9.9 029 1st floor, Room 129 Blue Wall Plaster Not intact >9.9 031 1st floor, Room 129 Blue Door casing Metal Not intact 4.7 032 1st floor, Room 128 White Wall Plaster Not intact >9.9 033 1st floor, Room 128 White Wall Plaster Not intact >9.9 034 1st floor, Room 128 Gray Door casing Metal Not intact 3.9 035 1st floor, Room 128 White Column Plaster Not intact >9.9 036 1st floor, Room 128 White Wall Plaster Not intact >9.9 037 1st floor, Room 128 Brown Baseboard Ceramic Not intact >9.9 039 1st floor, Room 128 White Wall Plaster Not intact >9.9 041 1st floor, Room 128 Gray Door casing Metal Intact 3.4
1st floor, Room 128, Shower area Yellow Wall Ceramic tile Intact >9.9
1st floor, Room 128, Shower area Gray Wall Plaster Intact >9.9
1st floor, Room 128, Shower area Gray Door casing Metal Intact 3.1
1st floor, Room 131, Women's room Tan Wall Ceramic tile Intact 3.6
TBL II-8
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
1st floor, Room 131, Women's room Off-white Wall Plaster Intact 9.5
1st floor, Room 131, Women's room Off-white Wall Plaster Intact >9.9
1st floor, Room 131, Women's room Beige Door casing Metal Intact 6.0
1st floor, Room 131, Women's room Off-white Ceiling Plaster Intact 6.0
1st floor, Room 140, Break room Beige Door casing Metal Intact 4.8 079 1st floor, Room 133 Green Wall Plaster Intact 9.1 080 1st floor, Room 133 Green Wall Column Plaster Intact 9.1 086 1st floor, Room 137 White Wall Plaster Intact 9.3 094 Stair No. 4 Black Stringer Metal Intact 0.8 099 1st floor, Room 122 White Wall Plaster Intact 8.8 100 1st floor, Room 122 Gray Door casing Metal Intact 3.9 101 1st floor, Room 122 White Wall Plaster Intact 7.9 102 1st floor, Room 120 Tan Wall Plaster Intact 7.8 104 1st floor, Room 120 Tan Wall Plaster Intact 6.3 106 1st floor, Room 120 Beige Door casing Metal Intact 4.2 107 1st floor, Room 120 White Ceiling Plaster Intact 4.9 114 1st floor, Room 107 White Wall Plaster Intact 7.0 115 1st floor, Room 107 White Wall Plaster Intact 7.6 119 Stair No. 1 Green Stair riser Metal Intact 0.8
2nd floor, east-west corridor Off-white Wall Plaster Intact >9.9
2nd floor, east-west corridor Off-white Wall Plaster Intact >9.9 134 2nd floor, Room 237 Pink Wall Plaster Intact >9.9 142 2nd floor, Room 225 Off-white Wall Plaster Intact >9.9 143 2nd floor, Room 225 Off-white Wall Plaster Intact >9.9 144 2nd floor, Room 225 Off-white Wall Plaster Intact >9.9 147 2nd floor, Room 217 Green Wall Plaster Intact 9.3 148 2nd floor, Room 217 Green Wall Plaster Intact 7.8 149 2nd floor, Room 217 Green Column Plaster Intact 9.2
2nd floor, Room 207, Men's room Off-white Wall Plaster Intact >9.9
2nd floor, Room 207, Men's room Off-white Wall Plaster Intact >9.9
2nd floor, Room 207, Men's room Off-white Wall Plaster Intact >9.9
2nd floor, Room 207, Men's room Beige Wall Ceramic tile Intact 4.4
2nd floor, Room 207, Men's room White Ceiling Plaster Intact >9.9
2nd floor, Room 210, Kitchenette Green Wall Plaster Intact >9.9
2nd floor, Room 210, Kitchenette Green Wall Plaster Intact >9.9
2nd floor, Room 210, Kitchenette Green Wall Plaster Intact >9.9 178 2nd floor, Room 212 Green Wall Plaster Intact 9.5
TBL II-9
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
183 Basement, Hall Off-white Wall Plaster Intact 4.3 184 Basement , Room 20 Beige Wall Plaster Intact 0.8 188 Basement, Room 20 White Sink Porcelain Intact 0.8 191 Basement, Room 20 Beige Door casing Metal Intact >9.9 192 Basement, Room 20 Beige Ceiling Concrete Not intact 0.8
Basement, Room 13, Men's Locker Blue Wall Plaster Intact 2.0
Basement, Room 13, Men's Locker Blue Wall Plaster Intact 0.8
Basement, Room 13, Men's Locker Blue Wall Plaster Intact 1.8
Basement, Room 13, Men's Locker Blue Radiator Metal Intact 0.8 202 Basement, Hall Yellow Ballard Metal Intact 1.5 203 Exterior White Door Frame Wood Not intact 3.4 205 Exterior Black Hand rail Metal Not intact 0.8
206 Exterior White Door trim base Concrete Not intact 0.8
207 Exterior White Door trim base Wood Not intact 1.9
211 Exterior Orange Down spout drain Metal Intact 0.8 Building 14
053 Hallway Off-white Support pole Metal Intact 3.4 054 Hallway Off-white Support pole Metal Intact 2.6 064 Chair quality P.B. Office Off-white Support pole Metal Intact 5.9 070 Hallway outside Lin PL6 White I-beam Metal Intact 3.4 072 Hallway outside Lin PL6 White Door casing Metal Intact 3.6 073 Hallway outside Lin PL6 Black Door casing Metal Intact 5.6 080 Vault drug storage White Ceiling Concrete Intact 3.2 082 Vault White Cage Metal Intact >9.9 083 Vault White Cage Metal Intact 9.6 085 Vault White Support pole Metal Intact 4.9 087 Vault Gray Floor Terracotta Not intact 0.8 088 Vault Gray I-beam Metal Intact 8.1 091 Label production control White Wall Concrete Intact 3.8 092 Label production control Off-white Door Wood Intact 5.8 093 Label production control Tan Door casing Metal Intact 5.5 096 Finished lable storage White Wall Concrete Intact 0.8 098 Lable production hall Blue I-beam Metal Intact 0.8 104 Lable production room Tan Wall Concrete Intact 6.5 191 Clinical trials & assembly Yellow Stair railing Metal Intact 1.3
194 Clinical trials & assembly Gray Window sash Metal Not intact 6.2
196 Clinical trials & assembly White Ceiling Concrete Intact 3.3
198 Mechanical room White Wall Cinder block Intact 5.6 200 Mechanical room White Wall Concrete Intact 5.4 205 Exterior Brown Window sill Metal Intact 0.8 213 Exterior Tan Wall Concrete Intact 5.2
TBL II-10
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
215 Exterior Tan Base Concrete Intact 0.8 217 Exterior Yellow Safety rail Metal Intact 2.7 226 Exterior Tan Wall Concrete Intact 5.8 227 Exterior Tan Window sill Concrete Intact 0.8 228 Exterior Tan Window sash Metal Intact 0.8
Building 14H
010 1st floor - Room 144 Off-white Ceiling Plaster Not intact >9.9
1st floor - Northeast corridor Off-white Ceiling Plaster Not intact 8.1
1st floor - Northeast corridor Off-white Wall Plaster Not intact >9.9 057 1st floor - Dining room Off-white Ceiling Plaster Not intact >9.9 073 1st floor - Room 160 Off-white Ceiling Plaster Not intact >9.9
2nd floor - corridor outside
252 Red Door casing Metal Intact 5.5 124 2nd floor - Room 244 Off-white Ceiling Plaster Not intact >9.9 141 2nd floor - Room 231 Tan Ceiling Plaster Not intact >9.9
2nd floor - Corridor outside
Room 23 Tan Ceiling Plaster Not intact >9.9 169 2nd floor, Dining room Off-white Ceiling Plaster Not intact >9.9 170 2nd floor, Dining room Off-white Wall Plaster Not intact >9.9 190 Stairwell #3 - 1st floor Yellow Wall Plaster Intact >9.9 191 Stairwell #3 - 1st floor Yellow Wall Plaster Intact >9.9 193 Stairwell #3 - 1st floor Yellow Wall Plaster Intact >9.9 194 Stairwell #3 - 1st floor Black Newel post Metal Intact 7.7 195 Stairwell #3 - 1st floor Black Hand rail Metal Intact 2.2 196 Stairwell #3 - 1st floor Black Stringer Metal Intact 0.8 197 Stairwell #3 - 1st floor Black Stair riser Metal Intact 0.8 200 Stairwell #3 - 1st floor Red Door casing Metal Intact 1.3 201 Exterior White Door casing Wood Intact 6.4 205 Exterior Black Hand rail Metal Not intact 0.8 209 Exterior White Window casing Wood Not intact >9.9 211 Exterior White Grate Metal Not intact 4.6
Building 15
005 Entrance lobby White Wall Plaster Intact >9.9 016 Main corridor White Wall Brick Intact 3.4 019 Copy room White Wall Brick Intact 3.9 026 Women's room White Window casing Wood Intact >9.9 027 Women's room White Window sill Wood Intact 5.1 028 Women's room White Window sash Wood Intact 6.4 029 Women's room White Wall Brick Intact 0.8 031 Women's room White Sink Porcelain Intact >9.9 041 NY meeting room 8 Brown Window sash Wood Not intact >9.9
Community relations department 9 Tan Wall Brick Intact 1.7
Community relations department 9 Tan Wall Brick Intact 2.0
Community relations department 9 Off-whtie Window sash Wood Intact 3.1 051 Resource room White Wall Brick Intact 0.8
TBL II-11
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
055 Courtney & Ben's offices White Wall Brick Intact 0.8 057 Courtney & Ben's offices White Window sash Metal Intact 4.8 061 Chesapeake room II White Window sash Metal Intact >9.9 069 Room 15 storage Green Wall Brick Intact 0.8 078 Room 26 White Sink Porcelain Intact 3.1 093 Room 23 White Wall CMU Intact 0.8 120 Room 38 White Wall Brick Intact 0.8 126 Exterior Tan Support pole Metal Intact 0.8 130 Exterior Tan Window sash Metal Not intact 0.8 132 Exterior Black Hand rail Metal Intact 0.8 133 Exterior Tan I-beam Steel Not intact 4.6 135 Exterior Tan Support strip Metal Intact 5.8 138 Exterior White Pipe Metal Intact 0.8 139 Exterior Tan Window sash Metal Intact 2.1 141 Exterior White Wall Metal Intact >9.9 143 Exterior White Conduit pipe Metal Intact 0.8
146 Exterior Tan Structural beam Metal Not intact 3.9 150 Exterior Tan Door Wood Not intact >9.9 151 Exterior Tan Door frame Wood Not intact 5.6 154 Exterior Tan Window sash Metal Intact 1.1 156 Exterior Black Hand rail Metal Intact 0.8 158 Exterior Tan Window frame Wood Not intact >9.9 159 Exterior Tan Window sash Metal Not intact >9.9
Building 15H
009 1st floor - main entrance Tan Door casing Metal Intact >9.9 010 1st floor - main entrance Off-white Ceiling Plaster Intact >9.9
1st floor - corridor outside
Room 102 Tan Door casing Metal Intact >9.9
1st floor - hall outside
Room 104 White Wall Plaster Intact 8.3
1st floor - hall outside
Room 104 White Ceiling Plaster Intact >9.9 031 1st floor - Room 102 Yellow Wall Plaster Intact >9.9 032 1st floor - Room 102 White Ceiling Plaster Intact >9.9 034 1st floor - Room 102 Tan Door transom Wood Intact >9.9 037 1st floor - Room 102 White Sink Porcelain Intact 1.4 038 1st floor - Room 102 White Wall Ceramic Intact 6.0 046 Stairwell #1 White Wall Plaster Intact >9.9 048 Stairwell #1 Tan Door casing Metal Intact >9.9
1st floor - Room south of
103A Black Door casing Metal Intact 0.8 069 1st floor - Room 106 White Wall Plaster Intact >9.9 070 1st floor - Room 106 White Wall Plaster Intact >9.9 073 1st floor - Room 106 White Sink Porcelain Intact 0.8 074 1st floor - Room 106 White Urinal Porcelain Intact 6.1 079 1st floor - Room 106 Tan Door casing Metal Intact >9.9 095 2nd floor - Room 202 Yellow Door casing Metal Intact >9.9 096 2nd floor - Room 202 White Ceiling Plaster Intact >9.9 101 2nd floor - Room 215 White Sink Porcelain…
This is the start of the file's text. The full file is on GovTribe.