This document is an Exhibit N Space Requirement for a lease (RLP No. 36C24425R0039, Lease No. 36C24425L0011) for an EREC (Engineering Research and Development Center) facility. The space requirement details a comprehensive layout for a 7,400 square foot facility, including multiple specialized areas such as offices, conference rooms, industrial spaces, and specific technical rooms. Key spaces include three private offices, a 700 sq ft cubical area, a 400 sq ft conference/break room, a 100 sq ft telecommunications room, an 800 sq ft studio for small 3D printers, a 400 sq ft metal printer room, and various industrial zones like injection molding, router table, assembly, and storage areas. The document specifies precise requirements for each space, including door sizes, wall configurations, ventilation needs, and specific functional considerations such as privacy, sound protection, and security requirements for sensitive areas like the metal printer and powdered metal storage rooms.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXHIBIT N
RLP No. 36C24425R0039 Lease No. 36C24425L0011
Space Requirement - EREC
New Designation New SF Min Door/Egress Comments
Office 1 120 3'x6'-8"
Solid walls to the ceiling for privacy reasons, sound protected.
Office 2 100 3'x6'-8"
Solid walls to the ceiling for privacy reasons, sound protected.
Office 3 100 3'x6'-8"
Solid walls to the ceiling for privacy reasons, sound protected.
Cubical area 700 5'x6'-8" Galley 80 3'x6'-8"
Conference / Break room 400 3'x6'-8"
Conference room with an adjoining break galley. They galley may be separated from the conference room by a door. If additional space within the allotment is left over, we’d like to add to the conference room./Solid walls to the ceiling for privacy reasons, sound protected.
Telecommunications Room 100 3'x6'-8" Comply with EHRM
Studio/small 3D printers 800 6'x8'
Needs a lot of ventilation / cleanliness concern/Dedicated hand washing sink/ 4 solid walls to the ceiling, but not isolated or sound proofed.
Metal Printer Room 400 6'x8'
Explosive. Should be segregated space for best practices. Ref: Exhibit B Agency Specific Doc: Should have 4 solid walls to the ceiling to secure the room, but not isolated or sound proofed.
Powdered Metal Storage 100 3'x6'-8"
Should have 4 solid walls to the ceiling secure the room, but not isolated or sound proofed.
Soft-Goods Fabrication Room
800 8'x8'
Should have 4 solid walls to the ceiling to secure the room, but not isolated or sound proofed.
600 Injection Molding Table 600 Router Table 600 Assembly 400 Parts Cleaning 400 Shipping and Receiving 940 Storage
Janitorial Closet 10 Janitorial/Utility Closet with 4 Solid walls.
75 3'x6'-8" 75 3'x6'-8"
Rest Rooms
Garage door from Load Dock 11' wide x
9' Tall
Industrial Area-One big room with the Storage area caged in for security reasons.
Lessor: _____ Government: _______